MIB Browser

VOLIUS-OT-MIB

IPF Technology Ltd
This MIB describes all SNMP-enabled hardware produced by Volius,
such as Fiber optical receivers, Erbium-doped fiber amplifiers,
Optical switches, CATV optical transmitters.
Organization
Volius
Root OID
1.3.6.1.4.1.34652.1
Last updated
Objects
85
Source
Show full MIB
snmptranslate -m VOLIUS-OT-MIB -Tp
snmpwalk -v2c -c <community> -m VOLIUS-OT-MIB <host> 1.3.6.1.4.1.34652.1

Imports

INET-ADDRESS-MIBInetAddressIPv4
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso
SNMPv2-TCDateAndTime, DisplayString, MacAddress, PhysAddress, TEXTUAL-CONVENTION

OID tree

NameOIDTypeAccessStatusExample
Nvolius1.3.6.1.4.1.34652
IvlsGlobalModule1.3.6.1.4.1.34652.1
NvlsSystem1.3.6.1.4.1.34652.2
NvlsSystemGeneral1.3.6.1.4.1.34652.2.10
SvlsModelName1.3.6.1.4.1.34652.2.10.1DisplayStringROVS5704-1x32-Telnevia
SvlsSerialNumber1.3.6.1.4.1.34652.2.10.2DisplayStringRO257000316601711117
SvlsFirmwareVersion1.3.6.1.4.1.34652.2.10.3DisplayStringRO2950
SvlsBootLoaderVersion1.3.6.1.4.1.34652.2.10.4DisplayStringRO\x07\xe6\x01\x18\x17\x14\x00\x00+\x07\x00
SvlsDateAndTime1.3.6.1.4.1.34652.2.10.5DateAndTimeRO420
SvlsTimeZone1.3.6.1.4.1.34652.2.10.6Integer32 (-720..780)RW389
SvlsCaseTemperature1.3.6.1.4.1.34652.2.10.7VlsDeciCelsiusRO
SvlsFanSpeed1.3.6.1.4.1.34652.2.10.8VlsRPMRO0
TvlsSupplyVoltageTable1.3.6.1.4.1.34652.2.10.9NA
RvlsSupplyVoltageEntry1.3.6.1.4.1.34652.2.10.9.1NA
CvlsSupplyVoltageIndex1.3.6.1.4.1.34652.2.10.9.1.1Integer32RO
CvlsSupplyVoltageNominal1.3.6.1.4.1.34652.2.10.9.1.2VlsMillivoltRO
CvlsSupplyVoltageActual1.3.6.1.4.1.34652.2.10.9.1.3VlsMillivoltRO
NvlsNetworkServices1.3.6.1.4.1.34652.2.11
NvlsNetworkAddress1.3.6.1.4.1.34652.2.11.5
SvlsMacAddress1.3.6.1.4.1.34652.2.11.5.1MacAddressRW"L2-Y
SvlsIpAddress1.3.6.1.4.1.34652.2.11.5.2InetAddressIPv4RW\n\xee\x00i
SvlsNetMask1.3.6.1.4.1.34652.2.11.5.3InetAddressIPv4RW\xff\xff\xff\xf8
SvlsDefaultGateway1.3.6.1.4.1.34652.2.11.5.4InetAddressIPv4RW\n\xee\x00n
NvlsHttp1.3.6.1.4.1.34652.2.11.6
SvlsHttpPort1.3.6.1.4.1.34652.2.11.6.1Integer32 (1..65535)RW
SvlsHttpEnabled1.3.6.1.4.1.34652.2.11.6.2VlsOnOffRW1
SvlsHttpPasswordEnabled1.3.6.1.4.1.34652.2.11.6.3VlsOnOffRW80
NvlsSnmp1.3.6.1.4.1.34652.2.11.7
SvlsSnmpPort1.3.6.1.4.1.34652.2.11.7.1Integer32 (1..65535)RW161
TvlsTrapDestTable1.3.6.1.4.1.34652.2.11.7.2NA
RvlsTrapDestEntry1.3.6.1.4.1.34652.2.11.7.2.1NA
CvlsTrapDestIndex1.3.6.1.4.1.34652.2.11.7.2.1.1Integer32RO1
CvlsTrapDestAddr1.3.6.1.4.1.34652.2.11.7.2.1.2InetAddressIPv4RWm\xc3@\x19
CvlsTrapDestPort1.3.6.1.4.1.34652.2.11.7.2.1.3Integer32 (1..65535)RW162
CvlsTrapDestEnable1.3.6.1.4.1.34652.2.11.7.2.1.4VlsOnOffRW2
NvlsSntp1.3.6.1.4.1.34652.2.11.8
SvlsSntpServerAddr1.3.6.1.4.1.34652.2.11.8.1InetAddressIPv4RWm\xc3@\x01
SvlsSntpServerPort1.3.6.1.4.1.34652.2.11.8.2Integer32 (1..65535)RW123
SvlsSntpEnabled1.3.6.1.4.1.34652.2.11.8.3VlsOnOffRW1
NvlsEventLog1.3.6.1.4.1.34652.2.13
SvlsLastEventCode1.3.6.1.4.1.34652.2.13.1VlsEventRO
SvlsLastEventIndex1.3.6.1.4.1.34652.2.13.2Integer32RO
SvlsEventLogSize1.3.6.1.4.1.34652.2.13.3Integer32RO
TvlsEventLogTable1.3.6.1.4.1.34652.2.13.4NA
RvlsEventLogEntry1.3.6.1.4.1.34652.2.13.4.1NA
CvlsEventIndex1.3.6.1.4.1.34652.2.13.4.1.1Integer32RO
CvlsEventCode1.3.6.1.4.1.34652.2.13.4.1.2VlsEventRO
CvlsEventTimeStamp1.3.6.1.4.1.34652.2.13.4.1.3TimeTicksRO
CvlsEventDateTime1.3.6.1.4.1.34652.2.13.4.1.4DateAndTimeRO
CvlsEventMessage1.3.6.1.4.1.34652.2.13.4.1.5DisplayStringRO
!vlsEventTrap1.3.6.1.4.1.34652.2.13.8
NvlsAlarms1.3.6.1.4.1.34652.2.14
SvlsAlarmsActiveMask1.3.6.1.4.1.34652.2.14.1Integer32RO16
SvlsAlarmsResetMask1.3.6.1.4.1.34652.2.14.2Integer32RW0
TvlsAlarmsTable1.3.6.1.4.1.34652.2.14.3NA
RvlsAlarmsEntry1.3.6.1.4.1.34652.2.14.3.1NA
CvlsAlarmIndex1.3.6.1.4.1.34652.2.14.3.1.1Integer32RO1
CvlsAlarmState1.3.6.1.4.1.34652.2.14.3.1.2VlsOnOffRW2
CvlsAlarmMessage1.3.6.1.4.1.34652.2.14.3.1.3DisplayStringROPump laser off
NvlsEdfa1.3.6.1.4.1.34652.3
NvlsOpticalSwitch1.3.6.1.4.1.34652.4
NvlsCatvTransmitter1.3.6.1.4.1.34652.5
SvlsTxEmissionState1.3.6.1.4.1.34652.5.1VlsOnOffRO
TvlsTxOutputTable1.3.6.1.4.1.34652.5.2NA
RvlsTxOutputEntry1.3.6.1.4.1.34652.5.2.1NA
CvlsTxOutputIndex1.3.6.1.4.1.34652.5.2.1.1Integer32RO
CvlsTxOutputPower1.3.6.1.4.1.34652.5.2.1.2VlsDeciDbmRO
SvlsTxPoutLowAlarm1.3.6.1.4.1.34652.5.3VlsDeciDbmRW
SvlsTxPoutHighAlarm1.3.6.1.4.1.34652.5.4VlsDeciDbmRW
SvlsTxInputComposite1.3.6.1.4.1.34652.5.5VlsDbmRO
SvlsTxInputPerChannel1.3.6.1.4.1.34652.5.6VlsDbuvRO
SvlsTxChannelPwrFactor1.3.6.1.4.1.34652.5.7VlsDeciDbRW
SvlsTxOmi1.3.6.1.4.1.34652.5.8VlsPerMilleRO
SvlsTxAtt1.3.6.1.4.1.34652.5.9VlsDeciDbRO
SvlsTxLaserCurrent1.3.6.1.4.1.34652.5.10VlsPercentRO
SvlsTxLaserTecCurrent1.3.6.1.4.1.34652.5.11VlsPercentRO
SvlsTxLaserPower1.3.6.1.4.1.34652.5.12VlsDeciDbmRO
SvlsTxLaserTemperature1.3.6.1.4.1.34652.5.13VlsDeciCelsiusRO
SvlsTxAgc1.3.6.1.4.1.34652.5.14VlsOnOffRW
SvlsTxSetOmi1.3.6.1.4.1.34652.5.15VlsPerMilleRW
SvlsTxSetAtt1.3.6.1.4.1.34652.5.16VlsDeciDbRW
SvlsTxSetSbsThreshold1.3.6.1.4.1.34652.5.17VlsDbmRW
NvlsOpticalReceiver1.3.6.1.4.1.34652.6
NvlsCabinetMonitor1.3.6.1.4.1.34652.7
NvlsUpsMonitor1.3.6.1.4.1.34652.8

Textual conventions

VlsDbm Integer32
Data type representing RF power readings in units of dBm.
VlsDbuv Integer32

Display hint: d

Data type representing RF power readings in units of dBuV.
VlsDeciCelsius Integer32

Display hint: d-1

Data type representing temperature readings in units of 0.1
degrees Celsius. For example, a temperature of -12.3 degrees
Celsius will be represented as -123.
VlsDeciDb Integer32
Data type representing RF gain in units of 0.1 dB. For
example, a gain of -2.5 dB will be represented as -25.
VlsDeciDbm Integer32

Display hint: d-1

Data type representing power readings in units of 0.1 dBm. For
example, a power of -2.5 dBm will be represented as -25.
VlsDeciDbo Integer32
Data type representing OMI readings in units of 0.1 dBo.
For example, an OMI of 10% will be represented as -100
(meaning -10.0 dBo),
an OMI of 1% will be represented
as -200 (meaning -20.0 dBo).
VlsEvent INTEGER

vlsEventFanLow(50) vlsEventFanNorm(49) vlsEventLaserCurrentHigh(42) vlsEventLaserCurrentLow(41) vlsEventLaserCurrentNorm(40) vlsEventLaserOff(21) vlsEventLaserOn(20) vlsEventLaserPowerHigh(45) vlsEventLaserPowerLow(44) vlsEventLaserPowerNorm(43) vlsEventLaserTempHigh(36) vlsEventLaserTempLow(35) vlsEventLaserTempNorm(34) vlsEventOmiHigh(48) vlsEventOmiLow(47) vlsEventOmiNorm(46) vlsEventPout1High(23) vlsEventPout1Low(24) vlsEventPout1Norm(22) vlsEventPout2High(26) vlsEventPout2Low(27) vlsEventPout2Norm(25) vlsEventRFinHigh(33) vlsEventRFinLow(32) vlsEventRFinNorm(31) vlsEventStartUp(1) vlsEventTcaseHigh(30) vlsEventTcaseLow(29) vlsEventTcaseNorm(28) vlsEventTecCurrentHigh(39) vlsEventTecCurrentLow(38) vlsEventTecCurrentNorm(37)

VlsMilliAmp Integer32
Data type representing electrical current values in units of mA.
VlsMillivolt Integer32

Display hint: d-3

Data type representing voltage values in units of mV.
VlsOnOff INTEGER

vlsOff(2) vlsOn(1)

Data type representing an on-off state.
VlsPerMille Integer32
Data type representing fractions, where percentage would
normally be used. 1 per mille corresponds to 0.1%.
For example. 99.9% would be 999 per mille.
VlsPercent Integer32
Data type representing fractions in units of 1%.
VlsRPM Integer32
Rotational speed in units of revolutions per minute.

Traps / Notifications