The UBQS-ENTITY-MIB is used to monitor
and configure operational status of
Field Replaceable Units (FRUs) and other managable
physical entities of the system listed in the
Entity-MIB (RFC 2737) entPhysicalTable.
Organization
Ubiquoss Corp.
Root OID
1.3.6.1.4.1.7800.100.3
Last updated
Objects
67
Source
Show full MIB
snmptranslate -m UBQS-ENTITY-MIB -Tp
snmpwalk -v2c -c <community> -m UBQS-ENTITY-MIB <host> 1.3.6.1.4.1.7800.100.3

Imports

ENTITY-MIBentPhysicalContainedIn, entPhysicalDescr, entPhysicalIndex, entPhysicalName
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION, TimeStamp, TruthValue
UBQS-SMIubiMgmtv2

OID tree

NameOIDTypeAccessStatus
IubiEntityMIB1.3.6.1.4.1.7800.100.3
NubiEntityMIBObjects1.3.6.1.4.1.7800.100.3.1
NubiEntityNotificationEnables1.3.6.1.4.1.7800.100.3.1.1
SubiFRUControlEnabled1.3.6.1.4.1.7800.100.3.1.1.1TruthValueRW
SubiEntSensorThresholdNotificationEnabled1.3.6.1.4.1.7800.100.3.1.1.2TruthValueRW
TubiModuleTable1.3.6.1.4.1.7800.100.3.1.2NA
RubiModuleEntry1.3.6.1.4.1.7800.100.3.1.2.1NA
CubiModuleId1.3.6.1.4.1.7800.100.3.1.2.1.1INTEGERRO
CubiModuleType1.3.6.1.4.1.7800.100.3.1.2.1.2DisplayStringRO
CubiModuleOperStatus1.3.6.1.4.1.7800.100.3.1.2.1.3ModuleOperTypeRO
CubiModuleStatusLastChangeTime1.3.6.1.4.1.7800.100.3.1.2.1.4TimeStampRO
CubiModuleSerialNumber1.3.6.1.4.1.7800.100.3.1.2.1.5DisplayStringRO
CubiModuleSlotNumber1.3.6.1.4.1.7800.100.3.1.2.1.6Integer32RO
CubiModulePortNumber1.3.6.1.4.1.7800.100.3.1.2.1.7Integer32RO
CubiModuleAction1.3.6.1.4.1.7800.100.3.1.2.1.8INTEGERRW
TubiSlotTable1.3.6.1.4.1.7800.100.3.1.3NA
RubiSlotEntry1.3.6.1.4.1.7800.100.3.1.3.1NA
CubiSlotModuleId1.3.6.1.4.1.7800.100.3.1.3.1.1INTEGERRO
CubiSlotId1.3.6.1.4.1.7800.100.3.1.3.1.2INTEGERRO
CubiSlotType1.3.6.1.4.1.7800.100.3.1.3.1.3DisplayStringRO
CubiSlotOperStatus1.3.6.1.4.1.7800.100.3.1.3.1.4ModuleOperTypeRO
CubiSlotPortNumber1.3.6.1.4.1.7800.100.3.1.3.1.5Integer32RO
CubiSlotSerialNumber1.3.6.1.4.1.7800.100.3.1.3.1.6DisplayStringRW
NubiExtSlot1.3.6.1.4.1.7800.100.3.1.4
SubiIEEE1588SlotOperStatus1.3.6.1.4.1.7800.100.3.1.4.1INTEGERRO
SubiMngSlotOperStatus1.3.6.1.4.1.7800.100.3.1.4.2INTEGERRO
NubiTransceiver1.3.6.1.4.1.7800.100.3.1.5
TubiEntitySensorTable1.3.6.1.4.1.7800.100.3.1.5.1NA
RubiEntitySensorEntry1.3.6.1.4.1.7800.100.3.1.5.1.1NA
CubiEntSensorType1.3.6.1.4.1.7800.100.3.1.5.1.1.1UbiSensorDataTypeRO
CubiEntSensorScale1.3.6.1.4.1.7800.100.3.1.5.1.1.2UbiSensorDataScaleRO
CubiEntSensorValue1.3.6.1.4.1.7800.100.3.1.5.1.1.3UbiSensorValueRO
CubiEntSensorEventStatus1.3.6.1.4.1.7800.100.3.1.5.1.1.4INTEGERRO
CubiEntSensorEventUpdateTime1.3.6.1.4.1.7800.100.3.1.5.1.1.5TimeStampRO
CubiEntSensorAlarmHighThreshold1.3.6.1.4.1.7800.100.3.1.5.1.1.6UbiSensorValueRW
CubiEntSensorWarningHighThreshold1.3.6.1.4.1.7800.100.3.1.5.1.1.7UbiSensorValueRW
CubiEntSensorWarningLowThreshold1.3.6.1.4.1.7800.100.3.1.5.1.1.8UbiSensorValueRW
CubiEntSensorAlarmLowThreshold1.3.6.1.4.1.7800.100.3.1.5.1.1.9UbiSensorValueRW
CubiEntSensorName1.3.6.1.4.1.7800.100.3.1.5.1.1.10DisplayStringRO
TubiTransceiverInfoTable1.3.6.1.4.1.7800.100.3.1.5.2NA
RubiTransceiverInfoEntry1.3.6.1.4.1.7800.100.3.1.5.2.1NA
CubiTcIdentifier1.3.6.1.4.1.7800.100.3.1.5.2.1.1UbiTcIdentifierRO
CubiTcVendorOUI1.3.6.1.4.1.7800.100.3.1.5.2.1.2DisplayStringRO
CubiTcVendorName1.3.6.1.4.1.7800.100.3.1.5.2.1.3DisplayStringRO
CubiTcVendorPartNumber1.3.6.1.4.1.7800.100.3.1.5.2.1.4DisplayStringRO
CubiTcVendorRevisionLevel1.3.6.1.4.1.7800.100.3.1.5.2.1.5DisplayStringRO
CubiTcVendorSerialNumber1.3.6.1.4.1.7800.100.3.1.5.2.1.6DisplayStringRO
CubiTcVendorManufacturingDate1.3.6.1.4.1.7800.100.3.1.5.2.1.7DisplayStringRO
CubiTcWaveLength1.3.6.1.4.1.7800.100.3.1.5.2.1.8Integer32RO
CubiTcConnector1.3.6.1.4.1.7800.100.3.1.5.2.1.9UbiTcConnectorTypeRO
CubiTcLength1.3.6.1.4.1.7800.100.3.1.5.2.1.10Integer32RO
SubiTransceiverMonitoring1.3.6.1.4.1.7800.100.3.1.5.3TruthValueRW
NubiEntityMIBNotificationPrefix1.3.6.1.4.1.7800.100.3.2
NubiFruNotifications1.3.6.1.4.1.7800.100.3.2.0
!ubiFRUInserted1.3.6.1.4.1.7800.100.3.2.0.1
!ubiFRURemoved1.3.6.1.4.1.7800.100.3.2.0.2
NubiEntitySensorNotifications1.3.6.1.4.1.7800.100.3.2.1
!ubiEntSensorThreshold1.3.6.1.4.1.7800.100.3.2.1.1
NubiEntityMIBConformance1.3.6.1.4.1.7800.100.3.3
NubiEntityMIBCompliances1.3.6.1.4.1.7800.100.3.3.1
MubiEntityMIBCompliance1.3.6.1.4.1.7800.100.3.3.1.1
NubiEntityMIBGroups1.3.6.1.4.1.7800.100.3.3.2
GubiEntityMIBModuleGroup1.3.6.1.4.1.7800.100.3.3.2.1
GubiEntitySlotGroup1.3.6.1.4.1.7800.100.3.3.2.2
GubiEntityMIBNotificationGroup1.3.6.1.4.1.7800.100.3.3.2.3
GubiEntiryMIBIEEE1588SlotGroup1.3.6.1.4.1.7800.100.3.3.2.4
GubiEntityMIBTransceiverGroup1.3.6.1.4.1.7800.100.3.3.2.5

Textual conventions

ModuleOperType INTEGER

disabled(3) ok(2) other(1)

Operational module states.  Valid values are :

unknown(1)            Module is not in one of other states
					  normal operational states:

ok(2)                 Module is operational.

disabled(3)           Module is administratively disabled.

selfTest(6)           Module is performing selfTest.


failure states:

failed(7)              Module has failed due to some condition
                     not stated above.

dormant(12)            Module is waiting for an external or
                     internal event to become operational.
UbiSensorDataScale INTEGER

atto(3) exa(14) femto(4) giga(12) kilo(10) mega(11) micro(7) milli(8) nano(6) peta(15) pico(5) tera(13) units(9) yocto(1) yotta(17) zepto(2) zetta(16)

International System of Units (SI) prefixes.
UbiSensorDataType INTEGER

amperes(4) celsius(5) cmm(10) dBm(6) hertz(14) other(1) percentRH(8) rpm(9) specialEnum(12) truthvalue(11) unknown(2) volts(3) watts(13)

sensor measurement data types.  valid values are:
other(1):        a measure other than those listed below
unknown(2):      unknown measurement, or
                 arbitrary, relative numbers
volts(3):      electric potential
amperes(4):      electric current
celsius(5):      temperature
dBm(6):         dB relative to 1mW of power
percentRH(8):    percent relative humidity
rpm(9):         shaft revolutions per minute
cmm(10),:        cubic meters per minute (airflow)
truthvalue(11):  value takes { true(1), false(2) }
specialEnum(12): value takes user defined enumerated values
watts(13):        power
hertz(14):        frequency
UbiSensorPrecision INTEGER (-8..9)
When in the range 1 to 9, SensorPrecision is the number
of decimal places in the fractional part of
a SensorValue fixed-point number.  When in the range -8 to
-1, SensorPrecision is the number of accurate digits in
a SensorValue fixed-point number.

SensorPrecision is 0 for non-fixed-point numbers.

Agent implementors must choose a value for SensorPrecision
so that the precision and accuracy of a SensorValue is
correctly indicated.

For example, a temperature sensor that can measure 0o to
100o C in 0.1o increments, +/- 0.05o, would have a
SensorPrecision of 1, a SensorDataScale of units(0), and a
SensorValue ranging from 0 to 1000.
The SensorValue would be interpreted as (degrees C * 10).

If that temperature sensor's precision were 0.1o but its
accuracy were only +/- 0.5o, then the SensorPrecision would
be 0. The SensorValue would be interpreted as degrees C.

Another example: a fan rotation speed sensor that measures RPM
from 0 to 10,000 in 100 RPM increments, with an accuracy of
+50/-37 RPM, would have a SensorPrecision of -2, a
SensorDataScale of units(9), and a SensorValue ranging from 0
to 10000. The 10s and 1s digits of SensorValue would always
be 0.
UbiSensorValue OCTET STRING
Represent the sensor value
UbiSensorValue_cisco INTEGER (-1000000000..1000000000)
For sensors that measure voltsAC, voltsDC,
amperes, watts, hertz, celsius, cmm
this item is a fixed point number ranging from
-999,999,999 to +999,999,999.  Use the value
-1000000000 to indicate underflow. Use the value
+1000000000 to indicate overflow.  Use SensorPrecision
to indicate how many fractional digits the SensorValue
has.


For sensors that measure percentRH, this item
is a number ranging from 0 to 100.

For sensors that measure rpm, this item
can take only nonnegative values, 0..999999999.

For sensors of type truthvalue, this item
can take only two values: true(1), false(2).

For sensors of type specialEnum, this item
can take any value in the range (-1000000000..1000000000),
but the meaning of each value is specific to the
sensor.

For sensors of type other and unknown,
this item can take any value in the range
(-1000000000..1000000000), but the meaning of the values
are specific to the sensor.

Use Entity-MIB entPhysicalTable.entPhysicalVendorType
to learn about the sensor type.
UbiTcConnectorType INTEGER

bnc_tnc(5) copper_pigtail(13) fiber_coaxial(6) fiber_style1_copper(3) fiber_stype2_copper(4) fiberjack(7) hssdc2(12) lc(8) mt_rj(9) optical_pigtail(11) other(1) sc(2) sg(10) unknown(0)

UbiTcEncodingType INTEGER

enc_4b5b(3) enc_64b(2) enc_8b10b(4) enc_manchester(8) enc_nrz(6) enc_rz(7) enc_sonet(5) other(1) unknown(0)

UbiTcIdentifier INTEGER

gbic(2) module(3) other(1) sfp(4) unknown(0) x2(11) xbi(5) xenpak(6) xff(8) xfp(7) xfp_e(9) xpak(10)