TPDIN2-MIB
Tycon Systems Inc.TPDIN Monitor Web V2 custom MIB
snmptranslate -m TPDIN2-MIB -Tpsnmpwalk -v2c -c <community> -m TPDIN2-MIB <host> 1.3.6.1.4.1.45621.2Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ntycon | 1.3.6.1.4.1.45621 | ||||||||||||
| Itpdin2 | 1.3.6.1.4.1.45621.2 | ||||||||||||
identity TPDIN Monitor Web V2 custom MIB | |||||||||||||
| Nproduct | 1.3.6.1.4.1.45621.2.1 | ||||||||||||
| Sname | 1.3.6.1.4.1.45621.2.1.1 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current Product name. | |||||||||||||
| Sversion | 1.3.6.1.4.1.45621.2.1.2 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current Product version. | |||||||||||||
| Sbuilddate | 1.3.6.1.4.1.45621.2.1.3 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current Build date. | |||||||||||||
| Nmonitor | 1.3.6.1.4.1.45621.2.2 | ||||||||||||
| Srelay1 | 1.3.6.1.4.1.45621.2.2.1 | INTEGER | RW | 1 | |||||||||
scalar · INTEGER · read-write · current Relay 1 Example values from LibreNMS test devices
| |||||||||||||
| Srelay2 | 1.3.6.1.4.1.45621.2.2.2 | INTEGER | RW | 1 | |||||||||
scalar · INTEGER · read-write · current Relay 2 Example values from LibreNMS test devices
| |||||||||||||
| Srelay3 | 1.3.6.1.4.1.45621.2.2.3 | INTEGER | RW | 0 | |||||||||
scalar · INTEGER · read-write · current Relay 3 Example values from LibreNMS test devices
| |||||||||||||
| Srelay4 | 1.3.6.1.4.1.45621.2.2.4 | INTEGER | RW | 0 | |||||||||
scalar · INTEGER · read-write · current Relay 4 Example values from LibreNMS test devices
| |||||||||||||
| Svoltage1 | 1.3.6.1.4.1.45621.2.2.5 | Tenths | RO | 54.1 | |||||||||
scalar · Tenths · read-only · current Voltage 1 Example values from LibreNMS test devices
| |||||||||||||
| Svoltage2 | 1.3.6.1.4.1.45621.2.2.6 | Tenths | RO | .0 | |||||||||
scalar · Tenths · read-only · current Voltage 2 Example values from LibreNMS test devices
| |||||||||||||
| Svoltage3 | 1.3.6.1.4.1.45621.2.2.7 | Tenths | RO | 23.9 | |||||||||
scalar · Tenths · read-only · current Voltage 3 Example values from LibreNMS test devices
| |||||||||||||
| Svoltage4 | 1.3.6.1.4.1.45621.2.2.8 | Tenths | RO | .0 | |||||||||
scalar · Tenths · read-only · current Voltage 4 Example values from LibreNMS test devices
| |||||||||||||
| Scurrent1 | 1.3.6.1.4.1.45621.2.2.9 | Tenths | RO | .0 | |||||||||
scalar · Tenths · read-only · current Current 1 Example values from LibreNMS test devices
| |||||||||||||
| Scurrent2 | 1.3.6.1.4.1.45621.2.2.10 | Tenths | RO | .0 | |||||||||
scalar · Tenths · read-only · current Current 2 Example values from LibreNMS test devices
| |||||||||||||
| Scurrent3 | 1.3.6.1.4.1.45621.2.2.11 | Tenths | RO | .0 | |||||||||
scalar · Tenths · read-only · current Current 3 Example values from LibreNMS test devices
| |||||||||||||
| Scurrent4 | 1.3.6.1.4.1.45621.2.2.12 | Tenths | RO | .0 | |||||||||
scalar · Tenths · read-only · current Current 4 Example values from LibreNMS test devices
| |||||||||||||
| Stemperature1 | 1.3.6.1.4.1.45621.2.2.13 | Tenths | RO | 14.4 | |||||||||
scalar · Tenths · read-only · current External Temp Example values from LibreNMS test devices
| |||||||||||||
| Stemperature2 | 1.3.6.1.4.1.45621.2.2.14 | Tenths | RO | 25.4 | |||||||||
scalar · Tenths · read-only · current Internal Temp Example values from LibreNMS test devices
| |||||||||||||
Textual conventions
TenthsINTEGER (0..10000)Display hint:
d-1tenths