TPLINK-DDMSTATUS-MIB
TP-Link Systems Inc.The view of DDM status.
snmptranslate -m TPLINK-DDMSTATUS-MIB -Tpsnmpwalk -v2c -c <community> -m TPLINK-DDMSTATUS-MIB <host> 1.3.6.1.4.1.11863.6.96.1.7Imports
| IF-MIB | ifIndex |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
| TPLINK-DDMMANAGE-MIB | tplinkDdmManageMIBObjects |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IddmStatus | 1.3.6.1.4.1.11863.6.96.1.7 | ||||||||||||||||||||
identity The view of DDM status. | |||||||||||||||||||||
| TddmStatusTable | 1.3.6.1.4.1.11863.6.96.1.7.1 | NA | |||||||||||||||||||
table · not-accessible · current A table that is used to view the DDM status for specific ports on the Switch. | |||||||||||||||||||||
| RddmStatusEntry | 1.3.6.1.4.1.11863.6.96.1.7.1.1 | NA | |||||||||||||||||||
| CddmStatusPort | 1.3.6.1.4.1.11863.6.96.1.7.1.1.1 | DisplayString (SIZE (0..255)) | RO | 1/0/25 | |||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-only · current This object indicates the port number. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CddmStatusTemperature | 1.3.6.1.4.1.11863.6.96.1.7.1.1.2 | DisplayString (SIZE (0..30)) | RO | 50.000000 | |||||||||||||||||
column · DisplayString (SIZE (0..30)) · read-only · current This object indicates the temperature of the port. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CddmStatusVoltage | 1.3.6.1.4.1.11863.6.96.1.7.1.1.3 | DisplayString (SIZE (0..30)) | RO | 3.416200 | |||||||||||||||||
column · DisplayString (SIZE (0..30)) · read-only · current This object indicates the voltage of the port. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CddmStatusBiasCurrent | 1.3.6.1.4.1.11863.6.96.1.7.1.1.4 | DisplayString (SIZE (0..30)) | RO | 9.568000 | |||||||||||||||||
column · DisplayString (SIZE (0..30)) · read-only · current This object indicates the bias current of the port. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CddmStatusTxPow | 1.3.6.1.4.1.11863.6.96.1.7.1.1.5 | DisplayString (SIZE (0..30)) | RO | 0.398000 | |||||||||||||||||
column · DisplayString (SIZE (0..30)) · read-only · current This object indicates the tx power of the port. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CddmStatusRxPow | 1.3.6.1.4.1.11863.6.96.1.7.1.1.6 | DisplayString (SIZE (0..30)) | RO | 0.251200 | |||||||||||||||||
column · DisplayString (SIZE (0..30)) · read-only · current This object indicates the rx power of the port. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CddmStatusDataReady | 1.3.6.1.4.1.11863.6.96.1.7.1.1.7 | DisplayString (SIZE (0..30)) | RO | False | |||||||||||||||||
column · DisplayString (SIZE (0..30)) · read-only · current This object indicates whether SFP is operational or not. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CddmStatusLossSignal | 1.3.6.1.4.1.11863.6.96.1.7.1.1.8 | DisplayString (SIZE (0..30)) | RO | False | |||||||||||||||||
column · DisplayString (SIZE (0..30)) · read-only · current This object indicates whether local SFP reports signal loss or not. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CddmStatusTxFault | 1.3.6.1.4.1.11863.6.96.1.7.1.1.9 | DisplayString (SIZE (0..30)) | RO | False | |||||||||||||||||
column · DisplayString (SIZE (0..30)) · read-only · current This object indicates whether remote SFP reports signal loss or not. Example values from LibreNMS test devices
| |||||||||||||||||||||