TPLINK-DDMBIASCURTHRESHOLD-MIB
TP-Link Systems Inc.The config of DDM bias current threshold.
snmptranslate -m TPLINK-DDMBIASCURTHRESHOLD-MIB -Tpsnmpwalk -v2c -c <community> -m TPLINK-DDMBIASCURTHRESHOLD-MIB <host> 1.3.6.1.4.1.11863.6.96.1.4Imports
| IF-MIB | ifIndex |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
| TPLINK-DDMMANAGE-MIB | tplinkDdmManageMIBObjects |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IddmBiasCurThreshold | 1.3.6.1.4.1.11863.6.96.1.4 | ||||||||||||||||||||
identity The config of DDM bias current threshold. | |||||||||||||||||||||
| TddmBiasCurThresholdTable | 1.3.6.1.4.1.11863.6.96.1.4.1 | NA | |||||||||||||||||||
table · not-accessible · current A table that is used to configure the DDM Bias Current Threshold for specific ports on the Switch. | |||||||||||||||||||||
| RddmBiasCurThresholdEntry | 1.3.6.1.4.1.11863.6.96.1.4.1.1 | NA | |||||||||||||||||||
| CddmBiasCurThresholdPort | 1.3.6.1.4.1.11863.6.96.1.4.1.1.1 | DisplayString (SIZE (0..255)) | RO | 1/0/25 | |||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-only · current This object indicates the port number. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CddmBiasCurThresholdHighAlarm | 1.3.6.1.4.1.11863.6.96.1.4.1.1.2 | OCTET STRING (SIZE (0..30)) | RW | 15.000000 | |||||||||||||||||
column · OCTET STRING (SIZE (0..30)) · read-write · current This object indicates the highest threshold for the alarm. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CddmBiasCurThresholdLowAlarm | 1.3.6.1.4.1.11863.6.96.1.4.1.1.3 | OCTET STRING (SIZE (0..30)) | RW | 1.000000 | |||||||||||||||||
column · OCTET STRING (SIZE (0..30)) · read-write · current This object indicates the lowest threshold for the alarm. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CddmBiasCurThresholdHighWarn | 1.3.6.1.4.1.11863.6.96.1.4.1.1.4 | OCTET STRING (SIZE (0..30)) | RW | 13.000000 | |||||||||||||||||
column · OCTET STRING (SIZE (0..30)) · read-write · current This object indicates the highest threshold for the warning. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CddmBiasCurThresholdLowWarn | 1.3.6.1.4.1.11863.6.96.1.4.1.1.5 | OCTET STRING (SIZE (0..30)) | RW | 2.000000 | |||||||||||||||||
column · OCTET STRING (SIZE (0..30)) · read-write · current This object indicates the lowest threshold for the warning. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CddmBiasCurThresholdPortLAG | 1.3.6.1.4.1.11863.6.96.1.4.1.1.6 | OCTET STRING (SIZE (0..30)) | RO | LAG1 | |||||||||||||||||
column · OCTET STRING (SIZE (0..30)) · read-only · current This object indicates the lag number of the port. Example values from LibreNMS test devices
| |||||||||||||||||||||