TIC-RMTI4-G9000-G2020-MIB
Toshiba Corporationsnmptranslate -m TIC-RMTI4-G9000-G2020-MIB -Tpsnmpwalk -v2c -c <community> -m TIC-RMTI4-G9000-G2020-MIB <host> 1.3.6.1.4.1.186Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | AutonomousType, DisplayString, PhysAddress, TEXTUAL-CONVENTION, TestAndIncr, TimeInterval, TimeStamp |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Ntoshiba | 1.3.6.1.4.1.186 | |||
| Nequ | 1.3.6.1.4.1.186.1 | |||
| NequUPS | 1.3.6.1.4.1.186.1.19 | |||
| NticUPS | 1.3.6.1.4.1.186.1.19.2 | |||
| Nrmti4 | 1.3.6.1.4.1.186.1.19.2.5 | |||
| NupsG9000-G2020 | 1.3.6.1.4.1.186.1.19.2.5.1 | |||
| !upsTrapFault | 1.3.6.1.4.1.186.1.19.2.5.1.0.1 | |||
notification Alarm: One or more fault/status alarm(s) reported. | ||||
| !upsTrapFaultClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.2 | |||
notification Alarm Clear: One or more fault/status reported. | ||||
| !upsTrapOnBattery | 1.3.6.1.4.1.186.1.19.2.5.1.0.3 | |||
notification Info: The UPS is on Battery Mode. | ||||
| !upsTrapOnBatteryClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.4 | |||
notification Info Clear: The UPS is on Battery Mode. | ||||
| !upsTrapBatteryLow | 1.3.6.1.4.1.186.1.19.2.5.1.0.5 | |||
notification Warning: Battery Low Voltage. | ||||
| !upsTrapBatteryLowClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.6 | |||
notification Warning Clear: Battery Low Voltage. | ||||
| !upsTrapBatteryDepleted | 1.3.6.1.4.1.186.1.19.2.5.1.0.7 | |||
notification Warning: UPS contains depleted batteries, it will be unable to support critical loads. Shutdown excess equipment to reduce load. | ||||
| !upsTrapBatteryDepletedClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.8 | |||
notification Warning Clear: UPS contains depleted batteries, it will be unable to support critical loads. Shutdown excess equipment to reduce load.. | ||||
| !upsTrapBatteryOverheat | 1.3.6.1.4.1.186.1.19.2.5.1.0.9 | |||
notification Fault: Battery Overheat. | ||||
| !upsTrapBatteryOverheatClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.10 | |||
notification Fault Clear: Battery Overheat. | ||||
| !upsTrapBatteryVoltageAbnormal | 1.3.6.1.4.1.186.1.19.2.5.1.0.11 | |||
notification Fault: Battery Voltage Abnormal. Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapBatteryVoltageAbnormalClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.12 | |||
notification Fault Clear: Battery Voltage Abnormal. Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapUPSOverheat | 1.3.6.1.4.1.186.1.19.2.5.1.0.13 | |||
notification Fault: UPS Overheat, heatsinks temperature exceeds thermal settings. Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapUPSOverheatClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.14 | |||
notification Fault Clear: UPS Overheat, heatsinks temperature exceeds thermal settings. Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapPowerFailure | 1.3.6.1.4.1.186.1.19.2.5.1.0.15 | |||
notification Info: Power Failure. | ||||
| !upsTrapPowerFailureClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.16 | |||
notification Info Clear: PowerFailure. | ||||
| !upsTrapUPSOverload | 1.3.6.1.4.1.186.1.19.2.5.1.0.17 | |||
notification Fault: UPS Overload (OL), the output load exceeds the rated current. Decrease load. | ||||
| !upsTrapUPSOverloadClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.18 | |||
notification Fault Clear: UPS Overload (OL), the output load exceeds the rated current. Decrease load. | ||||
| !upsTrapUserDefinedOverloadWarning | 1.3.6.1.4.1.186.1.19.2.5.1.0.19 | |||
notification Warning: The inverter output load % is greater than the user defined overload set point (default: 110%). | ||||
| !upsTrapUserDefinedOverloadWarningClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.20 | |||
notification Warning Clear: The inverter output load % is greater than the user defined overload set point (default: 110%). | ||||
| !upsTrapOnBypass | 1.3.6.1.4.1.186.1.19.2.5.1.0.21 | |||
notification Warning:On Bypass. | ||||
| !upsTrapOnBypassClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.22 | |||
notification Warning Clear: On Bypass. | ||||
| !upsTrapOutputOff | 1.3.6.1.4.1.186.1.19.2.5.1.0.23 | |||
notification Info: The UPS output is off. | ||||
| !upsTrapOutputOffClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.24 | |||
notification Info Clear: The UPS output is off. | ||||
| !upsTrapAsyncOperation | 1.3.6.1.4.1.186.1.19.2.5.1.0.25 | |||
notification Warning: Inverter Synchronous. | ||||
| !upsTrapAsyncOperationClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.26 | |||
notification Warning Clear: Inverter Synchronous. | ||||
| !upsTrapDCBusOverCurrent | 1.3.6.1.4.1.186.1.19.2.5.1.0.27 | |||
notification Fault: DC Overcurrent (DCOC). Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapDCBusOverCurrentClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.28 | |||
notification Fault Clear: DC Overcurrent (DCOC). Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapDCBusOverVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.0.29 | |||
notification Fault: DC Overvoltage (DCOV). Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapDCBusOverVoltageClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.30 | |||
notification Fault Clear: DC Overvoltage (DCOV). Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapDCBusUnderVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.0.31 | |||
notification Fault: DC Undervoltage (DCUV). Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapDCBusUnderVoltageClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.32 | |||
notification Fault Clear: DC Undervoltage (DCUV). Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapDCBusImbalance | 1.3.6.1.4.1.186.1.19.2.5.1.0.33 | |||
notification Fault: DC Unbalance. Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapDCBusImbalanceClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.34 | |||
notification Fault Clear: DC Unbalance. Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapOutputUnderVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.0.35 | |||
notification Fault: Output Undervoltage. Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapOutputUnderVoltageClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.36 | |||
notification Fault Clear: Output Undervoltage. Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapOutputOverVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.0.37 | |||
notification Fault: Output Overvoltage (VLOV). Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapOutputOverVoltageClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.38 | |||
notification Fault Clear: Output Overvoltage (VLOV). Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapInverterOverload | 1.3.6.1.4.1.186.1.19.2.5.1.0.39 | |||
notification Fault: UPS Overload, short time over-current has been detected during On-Line operation. Decrease Load. | ||||
| !upsTrapInverterOverloadClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.40 | |||
notification Fault Clear: UPS Overload, short time over-current has been detected during On-Line operation. Decrease Load. | ||||
| !upsTrapInverterOvercurrent | 1.3.6.1.4.1.186.1.19.2.5.1.0.41 | |||
notification Fault: Inverter Overcurrent. Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapInverterOvercurrentClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.42 | |||
notification Fault Clear: Inverter Overcurrent. Contact your Toshiba authorized service center for examination. | ||||
| !upsTrapRemotEyeCommError | 1.3.6.1.4.1.186.1.19.2.5.1.0.43 | |||
notification Warning: RemotEye UPS communication error. | ||||
| !upsTrapRemotEyeCommErrorClear | 1.3.6.1.4.1.186.1.19.2.5.1.0.44 | |||
notification Warning Clear:RemotEye UPS communication error. | ||||
| NupsIdent | 1.3.6.1.4.1.186.1.19.2.5.1.1 | |||
| SupsIdentManufacturer | 1.3.6.1.4.1.186.1.19.2.5.1.1.1 | DisplayString (SIZE (0..31)) | RO | mandatory |
scalar · DisplayString (SIZE (0..31)) · read-only · mandatory The name of the UPS manufacturer. | ||||
| SupsIdentTypeform | 1.3.6.1.4.1.186.1.19.2.5.1.1.2 | DisplayString (SIZE (0..127)) | RO | mandatory |
scalar · DisplayString (SIZE (0..127)) · read-only · mandatory The UPS Model designation. | ||||
| SupsIdentUPSFirmwareVersion | 1.3.6.1.4.1.186.1.19.2.5.1.1.3 | DisplayString (SIZE (0..63)) | RO | mandatory |
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory The UPS firmware version. | ||||
| SupsIdentSysName | 1.3.6.1.4.1.186.1.19.2.5.1.1.4 | DisplayString (SIZE (0..63)) | RW | mandatory |
scalar · DisplayString (SIZE (0..63)) · read-write · mandatory A string identifying the UPS. This object is set by the administrator. | ||||
| SupsIdentAttachedDevices | 1.3.6.1.4.1.186.1.19.2.5.1.1.5 | DisplayString (SIZE (0..63)) | RW | mandatory |
scalar · DisplayString (SIZE (0..63)) · read-write · mandatory A string identifying the devices attached to the output(s) of the UPS. This object is set by the administrator. | ||||
| NupsInput | 1.3.6.1.4.1.186.1.19.2.5.1.2 | |||
| SupsInputNumOfPhases | 1.3.6.1.4.1.186.1.19.2.5.1.2.1 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory Number of input lines. This data is used by upsInputNumLines. | ||||
| SupsInputLLVoltageAB | 1.3.6.1.4.1.186.1.19.2.5.1.2.2 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The input line to line voltage for AB in RMS volts.
| ||||
| SupsInputLLVoltageBC | 1.3.6.1.4.1.186.1.19.2.5.1.2.3 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The input line to line voltage for BC in RMS volts.
| ||||
| SupsInputLLVoltageCA | 1.3.6.1.4.1.186.1.19.2.5.1.2.4 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The input line to line voltage for CA in RMS volts.
| ||||
| SupsInputLLVoltagePercentAB | 1.3.6.1.4.1.186.1.19.2.5.1.2.5 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The input line to line voltage percent for AB.
| ||||
| SupsInputLLVoltagePercentBC | 1.3.6.1.4.1.186.1.19.2.5.1.2.6 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The input line to line voltage percent for BC.
| ||||
| SupsInputLLVoltagePercentCA | 1.3.6.1.4.1.186.1.19.2.5.1.2.7 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The input line to line voltage percent for CA.
| ||||
| SupsInputCurrentPhaseA | 1.3.6.1.4.1.186.1.19.2.5.1.2.8 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The input phase current for Phase A.
| ||||
| SupsInputCurrentPhaseB | 1.3.6.1.4.1.186.1.19.2.5.1.2.9 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The input phase current unit for Phase B.
| ||||
| SupsInputCurrentPhaseC | 1.3.6.1.4.1.186.1.19.2.5.1.2.10 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The input phase current unit for Phase C.
| ||||
| SupsInputFrequency | 1.3.6.1.4.1.186.1.19.2.5.1.2.11 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The input frequency unit 0.1 Hertz.
| ||||
| SupsInputActivePowerA | 1.3.6.1.4.1.186.1.19.2.5.1.2.12 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The magnitude of the present input true power for phase A.
| ||||
| SupsInputActivePowerB | 1.3.6.1.4.1.186.1.19.2.5.1.2.13 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The magnitude of the present input true power for phase B.
| ||||
| SupsInputActivePowerC | 1.3.6.1.4.1.186.1.19.2.5.1.2.14 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The magnitude of the present input true power for phase C.
| ||||
| SupsInputTotalActivePower | 1.3.6.1.4.1.186.1.19.2.5.1.2.15 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The magnitude of the total input true power.
| ||||
| SupsInputRatedLLVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.2.16 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The input line to line rated voltage in RMS volts.
| ||||
| NupsOutput | 1.3.6.1.4.1.186.1.19.2.5.1.3 | |||
| SupsOutputSource | 1.3.6.1.4.1.186.1.19.2.5.1.3.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| ||||
| SupsOutputNumOfPhases | 1.3.6.1.4.1.186.1.19.2.5.1.3.2 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The number of output lines utilized in this device. | ||||
| SupsOutputLLVoltageAB | 1.3.6.1.4.1.186.1.19.2.5.1.3.3 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The output line to line voltage for AB in RMS volts.
| ||||
| SupsOutputLLVoltageBC | 1.3.6.1.4.1.186.1.19.2.5.1.3.4 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The output line to line voltage for BC in RMS volts.
| ||||
| SupsOutputLLVoltageCA | 1.3.6.1.4.1.186.1.19.2.5.1.3.5 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The output line to line voltage for CA in RMS volts.
| ||||
| SupsOutputCurrentPhaseA | 1.3.6.1.4.1.186.1.19.2.5.1.3.6 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The Output phase current for phase A in amps.
| ||||
| SupsOutputCurrentPhaseB | 1.3.6.1.4.1.186.1.19.2.5.1.3.7 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The Output phase current for phase B in amps.
| ||||
| SupsOutputCurrentPhaseC | 1.3.6.1.4.1.186.1.19.2.5.1.3.8 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The Output phase current for phase C in amps.
| ||||
| SupsOutputFrequency | 1.3.6.1.4.1.186.1.19.2.5.1.3.9 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The Output Frequency for phase A in 1/10 of HZ.
| ||||
| SupsOutputCurrentPercentA | 1.3.6.1.4.1.186.1.19.2.5.1.3.10 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The output current for phase A in percent.
| ||||
| SupsOutputCurrentPercentB | 1.3.6.1.4.1.186.1.19.2.5.1.3.11 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The output current for phase B in percent.
| ||||
| SupsOutputCurrentPercentC | 1.3.6.1.4.1.186.1.19.2.5.1.3.12 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The output current for phase C in percent.
| ||||
| SupsOutputTotalActivePower | 1.3.6.1.4.1.186.1.19.2.5.1.3.13 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The output active power.
| ||||
| SupsOutputTotalActivePowerPercent | 1.3.6.1.4.1.186.1.19.2.5.1.3.14 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The output active power in percent.
| ||||
| SupsOutputPowerFactor | 1.3.6.1.4.1.186.1.19.2.5.1.3.15 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The UPS output power factor.
| ||||
| SupsOutputRatedActivePower | 1.3.6.1.4.1.186.1.19.2.5.1.3.16 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The output rated active power for the UPS.
| ||||
| SupsOutputRatedApparentPower | 1.3.6.1.4.1.186.1.19.2.5.1.3.17 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The output rated apparent power for the UPS.
| ||||
| SupsOutputRatedLLVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.3.18 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The output rated line to line voltage for the UPS.
| ||||
| NupsBypass | 1.3.6.1.4.1.186.1.19.2.5.1.4 | |||
| SupsBypassNumOfPhases | 1.3.6.1.4.1.186.1.19.2.5.1.4.1 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The number of bypass lines utilized. | ||||
| SupsBypassLLVoltageAB | 1.3.6.1.4.1.186.1.19.2.5.1.4.2 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The Bypass line to line voltage for AB in RMS volts.
| ||||
| SupsBypassLLVoltageBC | 1.3.6.1.4.1.186.1.19.2.5.1.4.3 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The Bypass line to line voltage for BC in RMS volts.
| ||||
| SupsBypassLLVoltageCA | 1.3.6.1.4.1.186.1.19.2.5.1.4.4 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The Bypass line to line voltage for CA in RMS volts.
| ||||
| SupsBypassFrequency | 1.3.6.1.4.1.186.1.19.2.5.1.4.5 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The Bypass frequency in 0.1 Hertz.
| ||||
| NupsBattery | 1.3.6.1.4.1.186.1.19.2.5.1.5 | |||
| SupsBatteryStatus | 1.3.6.1.4.1.186.1.19.2.5.1.5.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run time sufficient to handle the load. A value of batteryLow indicates the battery level is low. Continued operation in battery mode will deplate batteries. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output). A value of batteryDischarging indicates UPS system is in Battery power.
| ||||
| SupsElapsedTimeOnBatteryPower | 1.3.6.1.4.1.186.1.19.2.5.1.5.2 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory If the unit is on battery power, the elapsed time since the UPS on battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| ||||
| SupsEstimatedBatteryRuntime | 1.3.6.1.4.1.186.1.19.2.5.1.5.3 | PositiveInteger | RO | mandatory |
scalar · PositiveInteger · read-only · mandatory An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| ||||
| SupsBatteryVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.5.4 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The battery voltage DC.
| ||||
| SupsBatteryVoltagePercent | 1.3.6.1.4.1.186.1.19.2.5.1.5.5 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory Battery voltage in percent.
| ||||
| SupsBatteryEstimatedCharge | 1.3.6.1.4.1.186.1.19.2.5.1.5.6 | INTEGER (0..100) | RO | mandatory |
scalar · INTEGER (0..100) · read-only · mandatory An estimate of the charge to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| ||||
| SupsBatteryDischargeCurrent | 1.3.6.1.4.1.186.1.19.2.5.1.5.7 | Integer32 | RO | mandatory |
scalar · Integer32 · read-only · mandatory The present battery discharge Current in percent.
| ||||
| SupsBatteryChargeCurrent | 1.3.6.1.4.1.186.1.19.2.5.1.5.8 | Integer32 | RO | mandatory |
scalar · Integer32 · read-only · mandatory The present battery charge Current in percent.
| ||||
| SupsBatteryModel | 1.3.6.1.4.1.186.1.19.2.5.1.5.9 | DisplayString (SIZE (0..15)) | RW | mandatory |
scalar · DisplayString (SIZE (0..15)) · read-write · mandatory The Battery manufacturer. | ||||
| SupsBatteryInSeries | 1.3.6.1.4.1.186.1.19.2.5.1.5.10 | NonNegativeInteger | RW | mandatory |
scalar · NonNegativeInteger · read-write · mandatory The Battery rated holding time in minutes. | ||||
| SupsBatteryNumStrings | 1.3.6.1.4.1.186.1.19.2.5.1.5.11 | NonNegativeInteger | RW | mandatory |
scalar · NonNegativeInteger · read-write · mandatory The Battery rated holding time in minutes. | ||||
| SupsBatteryRatedAmpereHour | 1.3.6.1.4.1.186.1.19.2.5.1.5.12 | NonNegativeInteger | RW | mandatory |
scalar · NonNegativeInteger · read-write · mandatory The Battery rated holding time in minutes.
| ||||
| SupsBatteryRatedBackupTime | 1.3.6.1.4.1.186.1.19.2.5.1.5.13 | DisplayString (SIZE (0..8)) | RW | mandatory |
scalar · DisplayString (SIZE (0..8)) · read-write · mandatory The Battery rated holding time in minutes.
| ||||
| SupsBatteryInstallationDate | 1.3.6.1.4.1.186.1.19.2.5.1.5.14 | DisplayString (SIZE (10)) | RO | mandatory |
scalar · DisplayString (SIZE (10)) · read-only · mandatory The battery install date. | ||||
| NupsAlarm | 1.3.6.1.4.1.186.1.19.2.5.1.6 | |||
| SupsAlarmsPresent | 1.3.6.1.4.1.186.1.19.2.5.1.6.1 | Gauge32 | RO | mandatory |
scalar · Gauge32 · read-only · mandatory The present number of active alarm conditions. | ||||
| TupsAlarmTable | 1.3.6.1.4.1.186.1.19.2.5.1.6.2 | NA | mandatory | |
table · not-accessible · mandatory A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an OBJECT IDENTIFIER, upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent. | ||||
| RupsAlarmEntry | 1.3.6.1.4.1.186.1.19.2.5.1.6.2.1 | NA | mandatory | |
row · not-accessible · mandatory An entry containing information applicable to a particular alarm.
| ||||
| CupsAlarmId | 1.3.6.1.4.1.186.1.19.2.5.1.6.2.1.1 | PositiveInteger | NA | mandatory |
column · PositiveInteger · not-accessible · mandatory A unique identifier for an alarm condition. This value must remain constant. | ||||
| CupsAlarmDescr | 1.3.6.1.4.1.186.1.19.2.5.1.6.2.1.2 | AutonomousType | RO | mandatory |
column · AutonomousType · read-only · mandatory A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | ||||
| CupsAlarmTime | 1.3.6.1.4.1.186.1.19.2.5.1.6.2.1.3 | TimeStamp | RO | mandatory |
column · TimeStamp · read-only · mandatory The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0. | ||||
| NupsWellKnownAlarms | 1.3.6.1.4.1.186.1.19.2.5.1.6.3 | |||
| SupsAlarmFault | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Fault: A UPS fault/Alarm condition exists. | ||||
| SupsAlarmOnBattery | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.2 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Info: The UPS is on Battery mode; it is supplying output power from its batteries. | ||||
| SupsAlarmBatteryLow | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.3 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Warning: The battery level is low. It has dropped to less than 90% of its nominal value. Continued operation in Battery Mode will deplete Batteries and result in UPS output shut down. Reduce critical load to increase battery runtime. | ||||
| SupsAlarmBatteryDepleted | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.4 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Warning: UPS contains depleted batteries, it will be unable to support critical loads. Shut down excess equipment to reduce Load. | ||||
| SupsAlarmBatteryOverheat | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.5 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Fault: Detection of over temperature at the batteries. | ||||
| SupsAlarmBatteryVoltageAbnormal | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.6 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Fault: Battery voltage is abnormality. | ||||
| SupsAlarmUPSOverheat | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.7 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Fault: The UPS is overheating (warning is given when the internal temperature reaches and exceeds 50?C rise @ 40?C ambient). Check to see if the ambient temperature is abnormally high (40?C or more). If so, turn on air conditioning. Also, check ventilation fan at the back of the UPS for operation or obstructions. Otherwise, shut down the UPS and contact your Toshiba authorized service center. | ||||
| SupsAlarmPowerFailure | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.8 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Info: Power Failure. | ||||
| SupsAlarmUPSOverload | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.9 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Fault: The UPS is overloaded. UPS will switch to bypass operation or shut down if no action is taken. Shut down excess equipment to reduce Load. | ||||
| SupsAlarmUserDefinedOverloadWarning | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.10 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Warning: The inverter output load % is greater than the user defined overload set point (default: 110%). | ||||
| SupsAlarmOnBypass | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.11 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Warning: The UPS is in Stop (Bypass) mode. | ||||
| SupsAlarmOutputOff | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.12 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Info: The UPS output is off. | ||||
| SupsAlarmAsyncOperation | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.13 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Warning: Async Operation | ||||
| SupsAlarmDCBusOverCurrent | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.14 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Fault: UPS is reporting a DC bus overcurrent condition. Contact your Toshiba authorized service center for examination of a DCOC fault. | ||||
| SupsAlarmDCBusOverVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.15 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Fault: UPS is reporting a DC bus overvoltage condition. Contact your Toshiba authorized service center for examination of a DCOV fault. | ||||
| SupsAlarmDCBusUnderVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.16 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Fault: UPS is reporting a DC bus undervoltage condition. Contact your Toshiba authorized service center for examination of a DCUV fault. | ||||
| SupsAlarmDCBusImbalanced | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.17 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Fault: The DC imbalanced alarm detection. | ||||
| SupsAlarmOutputUnderVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.18 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Fault: UPS is reporting an output undervoltage condition. Contact your Toshiba authorized service center for examination of a INVUV fault. | ||||
| SupsAlarmOutputOverVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.19 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Fault: UPS is reporting an output overvoltage condition. Contact your Toshiba authorized service center for examination of a INVOV fault. | ||||
| SupsAlarmInverterOverload | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.20 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Fault: Short time over-current has been detected. | ||||
| SupsAlarmInverterOvercurrent | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.21 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Fault: Detection of inverter overcurrent. | ||||
| SupsAlarmRemotEyeCommError | 1.3.6.1.4.1.186.1.19.2.5.1.6.3.22 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Warning: Communication error between the RemotEye 4 and the UPS. | ||||
| NupsConfig | 1.3.6.1.4.1.186.1.19.2.5.1.7 | |||
| SupsConfigModelIDString | 1.3.6.1.4.1.186.1.19.2.5.1.7.1 | DisplayString (SIZE (0..63)) | RO | mandatory |
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory UPS Model ID string. This string contains codes for the UPS series,input voltage, output voltage, output VA, and addition option. | ||||
| SupsConfigUPSFirmwareVersion | 1.3.6.1.4.1.186.1.19.2.5.1.7.2 | DisplayString (SIZE (0..63)) | RO | mandatory |
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory The G9000 software version. | ||||
| SupsConfigInputNumOfPhases | 1.3.6.1.4.1.186.1.19.2.5.1.7.3 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory Number of input lines. This data is used by upsInputNumLines. | ||||
| SupsConfigRatedInputFrequency | 1.3.6.1.4.1.186.1.19.2.5.1.7.4 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.
| ||||
| SupsConfigRatedInputLLVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.7.5 | NonNegativeInteger | RW | mandatory |
scalar · NonNegativeInteger · read-write · mandatory The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.
| ||||
| SupsConfigRatedInputPowerFactor | 1.3.6.1.4.1.186.1.19.2.5.1.7.6 | PositiveInteger | RO | mandatory |
scalar · PositiveInteger · read-only · mandatory UNITS are in hundredths. For 0.95 = 95.
| ||||
| SupsConfigOutputNumOfPhases | 1.3.6.1.4.1.186.1.19.2.5.1.7.7 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory Number of output lines. This data is used by upsOutputNumLines. | ||||
| SupsConfigRatedOutputFrequency | 1.3.6.1.4.1.186.1.19.2.5.1.7.8 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., bad Value for SNMPv1, or inconsistent Value for SNMPv2.
| ||||
| SupsConfigRatedOutputLLVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.7.9 | NonNegativeInteger | RW | mandatory |
scalar · NonNegativeInteger · read-write · mandatory The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., bad Value for SNMPv1, or inconsistent Value for SNMPv2.
| ||||
| SupsConfigRatedOutputApperentPower | 1.3.6.1.4.1.186.1.19.2.5.1.7.10 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The magnitude of the nominal Volt-Amp rating.
| ||||
| SupsConfigRatedOutputActivePower | 1.3.6.1.4.1.186.1.19.2.5.1.7.11 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The magnitude of the nominal true power rating.
| ||||
| SupsConfigRatedOutputPowerFactor | 1.3.6.1.4.1.186.1.19.2.5.1.7.12 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory UNITS are in hundredths. For 0.70 = 70.
| ||||
| SupsConfigBypassNumOfPhases | 1.3.6.1.4.1.186.1.19.2.5.1.7.13 | NonNegativeInteger | RO | mandatory |
scalar · NonNegativeInteger · read-only · mandatory The number of bypass lines utilized. | ||||
| SupsConfigLowVoltageTransferPoint | 1.3.6.1.4.1.186.1.19.2.5.1.7.14 | NonNegativeInteger | RW | mandatory |
scalar · NonNegativeInteger · read-write · mandatory The minimum input line voltage allowed before the UPS system transfers to battery backup.
| ||||
| SupsConfigHighVoltageTransferPoint | 1.3.6.1.4.1.186.1.19.2.5.1.7.15 | NonNegativeInteger | RW | mandatory |
scalar · NonNegativeInteger · read-write · mandatory The maximum line voltage allowed before the UPS system transfers to battery backup.
| ||||
| SupsConfigBatteryInSeries | 1.3.6.1.4.1.186.1.19.2.5.1.7.16 | NonNegativeInteger | RW | mandatory |
scalar · NonNegativeInteger · read-write · mandatory The number of batteries in each string connected in series. | ||||
| SupsConfigBatteryNumStrings | 1.3.6.1.4.1.186.1.19.2.5.1.7.17 | NonNegativeInteger | RW | mandatory |
scalar · NonNegativeInteger · read-write · mandatory The number of parallel battery strings. | ||||
| SupsConfigRatedBatteryVoltage | 1.3.6.1.4.1.186.1.19.2.5.1.7.18 | NonNegativeInteger | RW | mandatory |
scalar · NonNegativeInteger · read-write · mandatory Rated voltage of a single battery.
| ||||
| SupsConfigRatedBatteryAmpereHour | 1.3.6.1.4.1.186.1.19.2.5.1.7.19 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The rated battery in ampere hour.
| ||||
| SupsConfigBatteryModel | 1.3.6.1.4.1.186.1.19.2.5.1.7.20 | DisplayString (SIZE (0..31)) | RW | mandatory |
scalar · DisplayString (SIZE (0..31)) · read-write · mandatory The manufacturer of the battery. | ||||
| SupsConfigBatteryRatedBackupTime | 1.3.6.1.4.1.186.1.19.2.5.1.7.21 | NonNegativeInteger | RW | mandatory |
scalar · NonNegativeInteger · read-write · mandatory The rated duration batteries can hold when unit is in backup mode with full load.
| ||||
| SupsConfigUserDefinedOverloadSetPoint | 1.3.6.1.4.1.186.1.19.2.5.1.7.22 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The maximum output load % defined by the user.
| ||||
| SupsConfigBatteryInstallationDate | 1.3.6.1.4.1.186.1.19.2.5.1.7.23 | DisplayString (SIZE (10)) | RW | mandatory |
scalar · DisplayString (SIZE (10)) · read-write · mandatory The battery install date.
| ||||
| SupsConfigSysName | 1.3.6.1.4.1.186.1.19.2.5.1.7.24 | DisplayString (SIZE (0..31)) | RW | mandatory |
scalar · DisplayString (SIZE (0..31)) · read-write · mandatory A string identifying the UPS. This object is set by the administrator. | ||||
| SupsConfigAttachedDevices | 1.3.6.1.4.1.186.1.19.2.5.1.7.25 | DisplayString (SIZE (0..31)) | RW | mandatory |
scalar · DisplayString (SIZE (0..31)) · read-write · mandatory A string identifying the devices attached to the output(s) of the UPS. This object is set by the administrator. | ||||
| SupsConfigPassword | 1.3.6.1.4.1.186.1.19.2.5.1.7.26 | DisplayString (SIZE (0..31)) | RW | mandatory |
scalar · DisplayString (SIZE (0..31)) · read-write · mandatory Password. | ||||
| NupsTime | 1.3.6.1.4.1.186.1.19.2.5.1.8 | |||
| SupsTimeRealDate | 1.3.6.1.4.1.186.1.19.2.5.1.8.1 | DisplayString (SIZE (0..31)) | RW | mandatory |
scalar · DisplayString (SIZE (0..31)) · read-write · mandatory Present date: year-month-date-day of the week. | ||||
| SupsTimeRealTime | 1.3.6.1.4.1.186.1.19.2.5.1.8.2 | DisplayString (SIZE (0..31)) | RW | mandatory |
scalar · DisplayString (SIZE (0..31)) · read-write · mandatory Present time (military format): hour-minute-second. For example,2:00pm would be 14:00:00. | ||||
| NupsTrap | 1.3.6.1.4.1.186.1.19.2.5.1.9 | |||
Traps / Notifications
- upsTrapAsyncOperation
1.3.6.1.4.1.186.1.19.2.5.1.0.25 - upsTrapAsyncOperationClear
1.3.6.1.4.1.186.1.19.2.5.1.0.26 - upsTrapBatteryDepleted
1.3.6.1.4.1.186.1.19.2.5.1.0.7 - upsTrapBatteryDepletedClear
1.3.6.1.4.1.186.1.19.2.5.1.0.8 - upsTrapBatteryLow
1.3.6.1.4.1.186.1.19.2.5.1.0.5 - upsTrapBatteryLowClear
1.3.6.1.4.1.186.1.19.2.5.1.0.6 - upsTrapBatteryOverheat
1.3.6.1.4.1.186.1.19.2.5.1.0.9 - upsTrapBatteryOverheatClear
1.3.6.1.4.1.186.1.19.2.5.1.0.10 - upsTrapBatteryVoltageAbnormal
1.3.6.1.4.1.186.1.19.2.5.1.0.11 - upsTrapBatteryVoltageAbnormalClear
1.3.6.1.4.1.186.1.19.2.5.1.0.12 - upsTrapDCBusImbalance
1.3.6.1.4.1.186.1.19.2.5.1.0.33 - upsTrapDCBusImbalanceClear
1.3.6.1.4.1.186.1.19.2.5.1.0.34 - upsTrapDCBusOverCurrent
1.3.6.1.4.1.186.1.19.2.5.1.0.27 - upsTrapDCBusOverCurrentClear
1.3.6.1.4.1.186.1.19.2.5.1.0.28 - upsTrapDCBusOverVoltage
1.3.6.1.4.1.186.1.19.2.5.1.0.29 - upsTrapDCBusOverVoltageClear
1.3.6.1.4.1.186.1.19.2.5.1.0.30 - upsTrapDCBusUnderVoltage
1.3.6.1.4.1.186.1.19.2.5.1.0.31 - upsTrapDCBusUnderVoltageClear
1.3.6.1.4.1.186.1.19.2.5.1.0.32 - upsTrapFault
1.3.6.1.4.1.186.1.19.2.5.1.0.1 - upsTrapFaultClear
1.3.6.1.4.1.186.1.19.2.5.1.0.2 - upsTrapInverterOvercurrent
1.3.6.1.4.1.186.1.19.2.5.1.0.41 - upsTrapInverterOvercurrentClear
1.3.6.1.4.1.186.1.19.2.5.1.0.42 - upsTrapInverterOverload
1.3.6.1.4.1.186.1.19.2.5.1.0.39 - upsTrapInverterOverloadClear
1.3.6.1.4.1.186.1.19.2.5.1.0.40 - upsTrapOnBattery
1.3.6.1.4.1.186.1.19.2.5.1.0.3 - upsTrapOnBatteryClear
1.3.6.1.4.1.186.1.19.2.5.1.0.4 - upsTrapOnBypass
1.3.6.1.4.1.186.1.19.2.5.1.0.21 - upsTrapOnBypassClear
1.3.6.1.4.1.186.1.19.2.5.1.0.22 - upsTrapOutputOff
1.3.6.1.4.1.186.1.19.2.5.1.0.23 - upsTrapOutputOffClear
1.3.6.1.4.1.186.1.19.2.5.1.0.24 - upsTrapOutputOverVoltage
1.3.6.1.4.1.186.1.19.2.5.1.0.37 - upsTrapOutputOverVoltageClear
1.3.6.1.4.1.186.1.19.2.5.1.0.38 - upsTrapOutputUnderVoltage
1.3.6.1.4.1.186.1.19.2.5.1.0.35 - upsTrapOutputUnderVoltageClear
1.3.6.1.4.1.186.1.19.2.5.1.0.36 - upsTrapPowerFailure
1.3.6.1.4.1.186.1.19.2.5.1.0.15 - upsTrapPowerFailureClear
1.3.6.1.4.1.186.1.19.2.5.1.0.16 - upsTrapRemotEyeCommError
1.3.6.1.4.1.186.1.19.2.5.1.0.43 - upsTrapRemotEyeCommErrorClear
1.3.6.1.4.1.186.1.19.2.5.1.0.44 - upsTrapUPSOverheat
1.3.6.1.4.1.186.1.19.2.5.1.0.13 - upsTrapUPSOverheatClear
1.3.6.1.4.1.186.1.19.2.5.1.0.14 - upsTrapUPSOverload
1.3.6.1.4.1.186.1.19.2.5.1.0.17 - upsTrapUPSOverloadClear
1.3.6.1.4.1.186.1.19.2.5.1.0.18 - upsTrapUserDefinedOverloadWarning
1.3.6.1.4.1.186.1.19.2.5.1.0.19 - upsTrapUserDefinedOverloadWarningClear
1.3.6.1.4.1.186.1.19.2.5.1.0.20