TELDAT-MIB
TELDAT, S.A.snmptranslate -m TELDAT-MIB -Tpsnmpwalk -v2c -c <community> -m TELDAT-MIB <host> 1.3.6.1.4.1.2007Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Counter32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, Opaque, TRAP-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Nteldat | 1.3.6.1.4.1.2007 | ||||||||||||||||||||
| !telSistemaEventos | 1.3.6.1.4.1.2007.0.1 | ||||||||||||||||||||
notification This trap shows the event happened in the system. In order to identify the event, the trap has the mask of the event and its parameters, moreover, the subsystem and the event number in the subsystem. Furthermore it has the sequence number of the traps of the same type. | |||||||||||||||||||||
| Nteladmin | 1.3.6.1.4.1.2007.1 | ||||||||||||||||||||
| Ntelobjid | 1.3.6.1.4.1.2007.1.1 | ||||||||||||||||||||
| NteldatSreTrap | 1.3.6.1.4.1.2007.1.1.1 | ||||||||||||||||||||
| NteldatSreTrap-GW | 1.3.6.1.4.1.2007.1.1.1.1 | ||||||||||||||||||||
| NteldatSreTrap-FLT | 1.3.6.1.4.1.2007.1.1.1.2 | ||||||||||||||||||||
| NteldatSreTrap-BRS | 1.3.6.1.4.1.2007.1.1.1.3 | ||||||||||||||||||||
| NteldatSreTrap-ARP | 1.3.6.1.4.1.2007.1.1.1.5 | ||||||||||||||||||||
| NteldatSreTrap-IP | 1.3.6.1.4.1.2007.1.1.1.10 | ||||||||||||||||||||
| NteldatSreTrap-ICMP | 1.3.6.1.4.1.2007.1.1.1.11 | ||||||||||||||||||||
| NteldatSreTrap-TCP | 1.3.6.1.4.1.2007.1.1.1.12 | ||||||||||||||||||||
| NteldatSreTrap-UDP | 1.3.6.1.4.1.2007.1.1.1.13 | ||||||||||||||||||||
| NteldatSreTrap-ORIP | 1.3.6.1.4.1.2007.1.1.1.15 | ||||||||||||||||||||
| NteldatSreTrap-SPF | 1.3.6.1.4.1.2007.1.1.1.17 | ||||||||||||||||||||
| NteldatSreTrap-TFTP | 1.3.6.1.4.1.2007.1.1.1.19 | ||||||||||||||||||||
| NteldatSreTrap-SNMP | 1.3.6.1.4.1.2007.1.1.1.21 | ||||||||||||||||||||
| NteldatSreTrap-SRT | 1.3.6.1.4.1.2007.1.1.1.72 | ||||||||||||||||||||
| NteldatSreTrap-BR | 1.3.6.1.4.1.2007.1.1.1.74 | ||||||||||||||||||||
| NteldatSreTrap-FTP | 1.3.6.1.4.1.2007.1.1.1.80 | ||||||||||||||||||||
| NteldatSreTrap-ETH | 1.3.6.1.4.1.2007.1.1.1.81 | ||||||||||||||||||||
| NteldatSreTrap-SL | 1.3.6.1.4.1.2007.1.1.1.83 | ||||||||||||||||||||
| NteldatSreTrap-TKR | 1.3.6.1.4.1.2007.1.1.1.84 | ||||||||||||||||||||
| NteldatSreTrap-SDLC | 1.3.6.1.4.1.2007.1.1.1.90 | ||||||||||||||||||||
| NteldatSreTrap-FR | 1.3.6.1.4.1.2007.1.1.1.92 | ||||||||||||||||||||
| NteldatSreTrap-PPP | 1.3.6.1.4.1.2007.1.1.1.95 | ||||||||||||||||||||
| NteldatSreTrap-X252 | 1.3.6.1.4.1.2007.1.1.1.97 | ||||||||||||||||||||
| NteldatSreTrap-X253 | 1.3.6.1.4.1.2007.1.1.1.98 | ||||||||||||||||||||
| NteldatSreTrap-RDSI | 1.3.6.1.4.1.2007.1.1.1.99 | ||||||||||||||||||||
| NteldatSreTrap-LLC | 1.3.6.1.4.1.2007.1.1.1.103 | ||||||||||||||||||||
| NteldatSreTrap-BAN | 1.3.6.1.4.1.2007.1.1.1.109 | ||||||||||||||||||||
| NteldatSreTrap-NBS | 1.3.6.1.4.1.2007.1.1.1.110 | ||||||||||||||||||||
| NteldatSreTrap-CIF | 1.3.6.1.4.1.2007.1.1.1.111 | ||||||||||||||||||||
| NteldatSreTrap-GSTP | 1.3.6.1.4.1.2007.1.1.1.112 | ||||||||||||||||||||
| NteldatSreTrap-FRBK | 1.3.6.1.4.1.2007.1.1.1.114 | ||||||||||||||||||||
| NteldatSreTrap-PRI | 1.3.6.1.4.1.2007.1.1.1.115 | ||||||||||||||||||||
| NteldatSreTrap-DLS | 1.3.6.1.4.1.2007.1.1.1.116 | ||||||||||||||||||||
| NteldatSreTrap-PCMC | 1.3.6.1.4.1.2007.1.1.1.118 | ||||||||||||||||||||
| NteldatSreTrap-LAPD | 1.3.6.1.4.1.2007.1.1.1.119 | ||||||||||||||||||||
| NteldatSreTrap-TNIP | 1.3.6.1.4.1.2007.1.1.1.120 | ||||||||||||||||||||
| NteldatSreTrap-MBBU | 1.3.6.1.4.1.2007.1.1.1.123 | ||||||||||||||||||||
| NteldatSreTrap-BIR64 | 1.3.6.1.4.1.2007.1.1.1.124 | ||||||||||||||||||||
| NteldatSreTrap-REXISMRU | 1.3.6.1.4.1.2007.1.1.1.125 | ||||||||||||||||||||
| NteldatSreTrap-REXISFT | 1.3.6.1.4.1.2007.1.1.1.126 | ||||||||||||||||||||
| NteldatSreTrap-ICUPLUS | 1.3.6.1.4.1.2007.1.1.1.127 | ||||||||||||||||||||
| NteldatSreTrap-Q933 | 1.3.6.1.4.1.2007.1.1.1.128 | ||||||||||||||||||||
| NteldatSreTrap-IPPN | 1.3.6.1.4.1.2007.1.1.1.129 | ||||||||||||||||||||
| NteldatSreTrap-RAD | 1.3.6.1.4.1.2007.1.1.1.130 | ||||||||||||||||||||
| NteldatSreTrap-H323 | 1.3.6.1.4.1.2007.1.1.1.131 | ||||||||||||||||||||
| NteldatSreTrap-DHCP | 1.3.6.1.4.1.2007.1.1.1.133 | ||||||||||||||||||||
| NteldatSreTrap-IP6 | 1.3.6.1.4.1.2007.1.1.1.134 | ||||||||||||||||||||
| NteldatSreTrap-TVRP | 1.3.6.1.4.1.2007.1.1.1.135 | ||||||||||||||||||||
| NteldatSreTrap-ATM | 1.3.6.1.4.1.2007.1.1.1.136 | ||||||||||||||||||||
| NteldatSreTrap-IPSEC | 1.3.6.1.4.1.2007.1.1.1.138 | ||||||||||||||||||||
| NteldatSreTrap-NTP | 1.3.6.1.4.1.2007.1.1.1.139 | ||||||||||||||||||||
| NteldatSreTrap-ADSL | 1.3.6.1.4.1.2007.1.1.1.140 | ||||||||||||||||||||
| NteldatSreTrap-HTTP | 1.3.6.1.4.1.2007.1.1.1.142 | ||||||||||||||||||||
| NteldatSreTrap-DEP | 1.3.6.1.4.1.2007.1.1.1.144 | ||||||||||||||||||||
| NteldatSreTrap-ASDP | 1.3.6.1.4.1.2007.1.1.1.145 | ||||||||||||||||||||
| NteldatSreTrap-LDAP | 1.3.6.1.4.1.2007.1.1.1.146 | ||||||||||||||||||||
| NteldatSreTrap-SCEP | 1.3.6.1.4.1.2007.1.1.1.147 | ||||||||||||||||||||
| NteldatSreTrap-P3OE | 1.3.6.1.4.1.2007.1.1.1.148 | ||||||||||||||||||||
| NteldatSreTrap-AT | 1.3.6.1.4.1.2007.1.1.1.149 | ||||||||||||||||||||
| NteldatSreTrap-ASYNC | 1.3.6.1.4.1.2007.1.1.1.150 | ||||||||||||||||||||
| NteldatSreTrap-SYNC | 1.3.6.1.4.1.2007.1.1.1.151 | ||||||||||||||||||||
| NteldatSreTrap-DNS | 1.3.6.1.4.1.2007.1.1.1.152 | ||||||||||||||||||||
| NteldatSreTrap-VSN | 1.3.6.1.4.1.2007.1.1.1.153 | ||||||||||||||||||||
| NteldatSreTrap-NAPT | 1.3.6.1.4.1.2007.1.1.1.154 | ||||||||||||||||||||
| NteldatSreTrap-VID | 1.3.6.1.4.1.2007.1.1.1.155 | ||||||||||||||||||||
| NteldatSreTrap-PRL | 1.3.6.1.4.1.2007.1.1.1.156 | ||||||||||||||||||||
| NteldatSreTrap-HDSL | 1.3.6.1.4.1.2007.1.1.1.157 | ||||||||||||||||||||
| NteldatSreTrap-PGMO | 1.3.6.1.4.1.2007.1.1.1.158 | ||||||||||||||||||||
| NteldatSreTrap-RTSP | 1.3.6.1.4.1.2007.1.1.1.159 | ||||||||||||||||||||
| NteldatSreTrap-DNAT | 1.3.6.1.4.1.2007.1.1.1.160 | ||||||||||||||||||||
| NteldatSreTrap-G703 | 1.3.6.1.4.1.2007.1.1.1.161 | ||||||||||||||||||||
| NteldatSreTrap-POLR | 1.3.6.1.4.1.2007.1.1.1.162 | ||||||||||||||||||||
| NteldatSreTrap-XN | 1.3.6.1.4.1.2007.1.1.1.163 | ||||||||||||||||||||
| NteldatSreTrap-XNS | 1.3.6.1.4.1.2007.1.1.1.164 | ||||||||||||||||||||
| NteldatSreTrap-IPX | 1.3.6.1.4.1.2007.1.1.1.165 | ||||||||||||||||||||
| NteldatSreTrap-IGMP | 1.3.6.1.4.1.2007.1.1.1.166 | ||||||||||||||||||||
| NteldatSreTrap-AINST | 1.3.6.1.4.1.2007.1.1.1.167 | ||||||||||||||||||||
| NteldatSreTrap-BGP | 1.3.6.1.4.1.2007.1.1.1.169 | ||||||||||||||||||||
| NteldatSreTrap-NSM | 1.3.6.1.4.1.2007.1.1.1.170 | ||||||||||||||||||||
| NteldatSreTrap-TLNT | 1.3.6.1.4.1.2007.1.1.1.171 | ||||||||||||||||||||
| NteldatSreTrap-L2TP | 1.3.6.1.4.1.2007.1.1.1.172 | ||||||||||||||||||||
| NteldatSreTrap-NSLA | 1.3.6.1.4.1.2007.1.1.1.173 | ||||||||||||||||||||
| NteldatSreTrap-VOIP | 1.3.6.1.4.1.2007.1.1.1.174 | ||||||||||||||||||||
| NteldatSreTrap-TTTP | 1.3.6.1.4.1.2007.1.1.1.175 | ||||||||||||||||||||
| NteldatSreTrap-IKE | 1.3.6.1.4.1.2007.1.1.1.176 | ||||||||||||||||||||
| NteldatSreTrap-HSSI | 1.3.6.1.4.1.2007.1.1.1.177 | ||||||||||||||||||||
| NteldatSreTrap-SCADA | 1.3.6.1.4.1.2007.1.1.1.178 | ||||||||||||||||||||
| NteldatSreTrap-VRRP | 1.3.6.1.4.1.2007.1.1.1.179 | ||||||||||||||||||||
| NteldatSreTrap-SIP | 1.3.6.1.4.1.2007.1.1.1.180 | ||||||||||||||||||||
| NteldatSreTrap-IPHC | 1.3.6.1.4.1.2007.1.1.1.181 | ||||||||||||||||||||
| NteldatSreTrap-DHCPC | 1.3.6.1.4.1.2007.1.1.1.182 | ||||||||||||||||||||
| NteldatSreTrap-CNSL | 1.3.6.1.4.1.2007.1.1.1.183 | ||||||||||||||||||||
| NteldatSreTrap-TLPHY | 1.3.6.1.4.1.2007.1.1.1.184 | ||||||||||||||||||||
| NteldatSreTrap-NHRP | 1.3.6.1.4.1.2007.1.1.1.185 | ||||||||||||||||||||
| NteldatSreTrap-SNAT | 1.3.6.1.4.1.2007.1.1.1.186 | ||||||||||||||||||||
| NteldatSreTrap-STUN | 1.3.6.1.4.1.2007.1.1.1.187 | ||||||||||||||||||||
| NteldatSreTrap-WLAN | 1.3.6.1.4.1.2007.1.1.1.188 | ||||||||||||||||||||
| NteldatSreTrap-SCDFW | 1.3.6.1.4.1.2007.1.1.1.189 | ||||||||||||||||||||
| NteldatSreTrap-HDLC | 1.3.6.1.4.1.2007.1.1.1.190 | ||||||||||||||||||||
| NteldatSreTrap-EAP | 1.3.6.1.4.1.2007.1.1.1.191 | ||||||||||||||||||||
| NteldatSreTrap-EIBZ | 1.3.6.1.4.1.2007.1.1.1.192 | ||||||||||||||||||||
| NteldatSreTrap-PHYS | 1.3.6.1.4.1.2007.1.1.1.193 | ||||||||||||||||||||
| NteldatSreTrap-SPOOF | 1.3.6.1.4.1.2007.1.1.1.194 | ||||||||||||||||||||
| NteldatSreTrap-IRVOZ | 1.3.6.1.4.1.2007.1.1.1.195 | ||||||||||||||||||||
| NteldatSreTrap-RSTP | 1.3.6.1.4.1.2007.1.1.1.196 | ||||||||||||||||||||
| NteldatSreTrap-TIDP | 1.3.6.1.4.1.2007.1.1.1.197 | ||||||||||||||||||||
| NteldatSreTrap-NOE | 1.3.6.1.4.1.2007.1.1.1.198 | ||||||||||||||||||||
| NteldatSreTrap-AFS | 1.3.6.1.4.1.2007.1.1.1.199 | ||||||||||||||||||||
| NteldatSreTrap-X28 | 1.3.6.1.4.1.2007.1.1.1.200 | ||||||||||||||||||||
| NteldatSreTrap-BFD | 1.3.6.1.4.1.2007.1.1.1.203 | ||||||||||||||||||||
| NteldatSreTrap-DNSU | 1.3.6.1.4.1.2007.1.1.1.204 | ||||||||||||||||||||
| NteldatSreTrap-UDP6 | 1.3.6.1.4.1.2007.1.1.1.205 | ||||||||||||||||||||
| NteldatSreTrap-ICM6O | 1.3.6.1.4.1.2007.1.1.1.206 | ||||||||||||||||||||
| NteldatSreTrap-CELL | 1.3.6.1.4.1.2007.1.1.1.208 | ||||||||||||||||||||
| NteldatSreTrap-SSL | 1.3.6.1.4.1.2007.1.1.1.209 | ||||||||||||||||||||
| NteldatSreTrap-SCCP | 1.3.6.1.4.1.2007.1.1.1.210 | ||||||||||||||||||||
| NteldatSreTrap-WWAN | 1.3.6.1.4.1.2007.1.1.1.211 | ||||||||||||||||||||
| NteldatSreTrap-ISTD | 1.3.6.1.4.1.2007.1.1.1.212 | ||||||||||||||||||||
| NteldatSreTrap-DOT1X | 1.3.6.1.4.1.2007.1.1.1.213 | ||||||||||||||||||||
| NteldatSreTrap-EOAM | 1.3.6.1.4.1.2007.1.1.1.214 | ||||||||||||||||||||
| NteldatSreTrap-SSH | 1.3.6.1.4.1.2007.1.1.1.215 | ||||||||||||||||||||
| NteldatSreTrap-CDP | 1.3.6.1.4.1.2007.1.1.1.216 | ||||||||||||||||||||
| NteldatSreTrap-PIO | 1.3.6.1.4.1.2007.1.1.1.217 | ||||||||||||||||||||
| NteldatSreTrap-FLOW | 1.3.6.1.4.1.2007.1.1.1.218 | ||||||||||||||||||||
| NteldatSreTrap-RIP | 1.3.6.1.4.1.2007.1.1.1.219 | ||||||||||||||||||||
| NteldatSreTrap-MGCP | 1.3.6.1.4.1.2007.1.1.1.220 | ||||||||||||||||||||
| NteldatSreTrap-TIPS | 1.3.6.1.4.1.2007.1.1.1.221 | ||||||||||||||||||||
| NteldatSreTrap-SRVP | 1.3.6.1.4.1.2007.1.1.1.222 | ||||||||||||||||||||
| NteldatSreTrap-SPI | 1.3.6.1.4.1.2007.1.1.1.223 | ||||||||||||||||||||
| NteldatSreTrap-VLI | 1.3.6.1.4.1.2007.1.1.1.224 | ||||||||||||||||||||
| NteldatSreTrap-ACAT | 1.3.6.1.4.1.2007.1.1.1.225 | ||||||||||||||||||||
| NteldatSreTrap-AAA | 1.3.6.1.4.1.2007.1.1.1.226 | ||||||||||||||||||||
| NteldatSreTrap-SDEV | 1.3.6.1.4.1.2007.1.1.1.227 | ||||||||||||||||||||
| NteldatSreTrap-G104 | 1.3.6.1.4.1.2007.1.1.1.228 | ||||||||||||||||||||
| NteldatSreTrap-I101 | 1.3.6.1.4.1.2007.1.1.1.229 | ||||||||||||||||||||
| NteldatSreTrap-IPSF | 1.3.6.1.4.1.2007.1.1.1.230 | ||||||||||||||||||||
| NteldatSreTrap-DH6C | 1.3.6.1.4.1.2007.1.1.1.231 | ||||||||||||||||||||
| NteldatSreTrap-NEIG | 1.3.6.1.4.1.2007.1.1.1.232 | ||||||||||||||||||||
| NteldatSreTrap-ND | 1.3.6.1.4.1.2007.1.1.1.233 | ||||||||||||||||||||
| NteldatSreTrap-ICM6 | 1.3.6.1.4.1.2007.1.1.1.234 | ||||||||||||||||||||
| NteldatSreTrap-LLDP | 1.3.6.1.4.1.2007.1.1.1.235 | ||||||||||||||||||||
| NteldatSreTrap-RIP6 | 1.3.6.1.4.1.2007.1.1.1.236 | ||||||||||||||||||||
| NteldatSreTrap-MLD6 | 1.3.6.1.4.1.2007.1.1.1.237 | ||||||||||||||||||||
| NteldatSreTrap-PIM | 1.3.6.1.4.1.2007.1.1.1.238 | ||||||||||||||||||||
| NteldatSreTrap-MRTE | 1.3.6.1.4.1.2007.1.1.1.239 | ||||||||||||||||||||
| NteldatSreTrap-ACL | 1.3.6.1.4.1.2007.1.1.1.240 | ||||||||||||||||||||
| NteldatSreTrap-SPF6 | 1.3.6.1.4.1.2007.1.1.1.241 | ||||||||||||||||||||
| NteldatSreTrap-NIC | 1.3.6.1.4.1.2007.1.1.1.242 | ||||||||||||||||||||
| NteldatSreTrap-MSDP | 1.3.6.1.4.1.2007.1.1.1.244 | ||||||||||||||||||||
| NteldatSreTrap-ACT | 1.3.6.1.4.1.2007.1.1.1.245 | ||||||||||||||||||||
| NteldatSreTrap-TDGS | 1.3.6.1.4.1.2007.1.1.1.255 | ||||||||||||||||||||
| NteldatSreTrap-GPSF | 1.3.6.1.4.1.2007.1.1.1.256 | ||||||||||||||||||||
| NteldatSreTrap-WNMS | 1.3.6.1.4.1.2007.1.1.1.257 | ||||||||||||||||||||
| NteldatSreTrap-DH6S | 1.3.6.1.4.1.2007.1.1.1.259 | ||||||||||||||||||||
| NteldatSreTrap-CFM | 1.3.6.1.4.1.2007.1.1.1.264 | ||||||||||||||||||||
| NteldatSreTrap-PRIME | 1.3.6.1.4.1.2007.1.1.1.265 | ||||||||||||||||||||
| NteldatSreTrap-SMGT | 1.3.6.1.4.1.2007.1.1.1.266 | ||||||||||||||||||||
| SsreTrapSubSist | 1.3.6.1.4.1.2007.1.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory First variable inside the variable-bindings field of the SNMP Trap-PDU: Events subsystem number. | |||||||||||||||||||||
| SsreTrapEvento | 1.3.6.1.4.1.2007.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Second variable inside the variable-bindings field of the SNMP Trap-PDU: Event number (inside the subsystem). | |||||||||||||||||||||
| SsreTrapVar1 | 1.3.6.1.4.1.2007.1.1.4 | Opaque | RO | mandatory | |||||||||||||||||
scalar · Opaque · read-only · mandatory Third variable inside the variable-bindings field of the SNMP Trap-PDU: first variable of the event mask. | |||||||||||||||||||||
| SsreTrapVar2 | 1.3.6.1.4.1.2007.1.1.5 | Opaque | RO | mandatory | |||||||||||||||||
scalar · Opaque · read-only · mandatory Fourth variable inside the variable-bindings field of the SNMP Trap-PDU: second variable of the event mask. | |||||||||||||||||||||
| SsreTrapVar3 | 1.3.6.1.4.1.2007.1.1.6 | Opaque | RO | mandatory | |||||||||||||||||
scalar · Opaque · read-only · mandatory Fifth variable inside the variable-bindings field of the SNMP Trap-PDU: third variable of the event mask. | |||||||||||||||||||||
| SsreTrapVar4 | 1.3.6.1.4.1.2007.1.1.7 | Opaque | RO | mandatory | |||||||||||||||||
scalar · Opaque · read-only · mandatory Sixth variable inside the variable-bindings field of the SNMP Trap-PDU: fourth variable of the event mask. | |||||||||||||||||||||
| SsreTrapVar5 | 1.3.6.1.4.1.2007.1.1.8 | Opaque | RO | mandatory | |||||||||||||||||
scalar · Opaque · read-only · mandatory Seventh variable inside the variable-bindings field of the SNMP Trap-PDU: fifth variable of the event mask. | |||||||||||||||||||||
| SsreTrapVar6 | 1.3.6.1.4.1.2007.1.1.9 | Opaque | RO | mandatory | |||||||||||||||||
scalar · Opaque · read-only · mandatory Eighth variable inside the variable-bindings field of the SNMP Trap-PDU: sixth variable of the event mask. | |||||||||||||||||||||
| SsreTrapVar7 | 1.3.6.1.4.1.2007.1.1.10 | Opaque | RO | mandatory | |||||||||||||||||
scalar · Opaque · read-only · mandatory Ninth variable inside the variable-bindings field of the SNMP Trap-PDU: seventh variable of the event mask. | |||||||||||||||||||||
| SsreTrapVar8 | 1.3.6.1.4.1.2007.1.1.11 | Opaque | RO | mandatory | |||||||||||||||||
scalar · Opaque · read-only · mandatory Tenth variable inside the variable-bindings field of the SNMP Trap-PDU: eighth variable of the event mask. | |||||||||||||||||||||
| SsreTrapVar9 | 1.3.6.1.4.1.2007.1.1.12 | Opaque | RO | mandatory | |||||||||||||||||
scalar · Opaque · read-only · mandatory Eleventh variable inside the variable-bindings field of the SNMP Trap-PDU: ninth variable of the event mask. | |||||||||||||||||||||
| Nequipo-rexis-mru | 1.3.6.1.4.1.2007.1.1.15 | ||||||||||||||||||||
| Nequipo-mbbu | 1.3.6.1.4.1.2007.1.1.16 | ||||||||||||||||||||
| Nequipo-bir-u | 1.3.6.1.4.1.2007.1.1.20 | ||||||||||||||||||||
| Nequipo-ebano | 1.3.6.1.4.1.2007.1.1.21 | ||||||||||||||||||||
| Nequipo-nucleox-plus | 1.3.6.1.4.1.2007.1.1.32 | ||||||||||||||||||||
| Nequipo-cbra | 1.3.6.1.4.1.2007.1.1.33 | ||||||||||||||||||||
| Nequipo-centrix-b | 1.3.6.1.4.1.2007.1.1.34 | ||||||||||||||||||||
| Nequipo-centrix-p | 1.3.6.1.4.1.2007.1.1.35 | ||||||||||||||||||||
| Nequipo-temis | 1.3.6.1.4.1.2007.1.1.36 | ||||||||||||||||||||
| Nequipo-novacom | 1.3.6.1.4.1.2007.1.1.37 | ||||||||||||||||||||
| Nequipo-router-maestro | 1.3.6.1.4.1.2007.1.1.38 | ||||||||||||||||||||
| Nequipo-cbra20 | 1.3.6.1.4.1.2007.1.1.39 | ||||||||||||||||||||
| Nequipo-np20h | 1.3.6.1.4.1.2007.1.1.40 | ||||||||||||||||||||
| Nequipo-icu-plus | 1.3.6.1.4.1.2007.1.1.41 | ||||||||||||||||||||
| Nequipo-centrix-f | 1.3.6.1.4.1.2007.1.1.42 | ||||||||||||||||||||
| Nequipo-cbra-tar | 1.3.6.1.4.1.2007.1.1.43 | ||||||||||||||||||||
| Nequipo-aura | 1.3.6.1.4.1.2007.1.1.44 | ||||||||||||||||||||
| Nequipo-kronos | 1.3.6.1.4.1.2007.1.1.45 | ||||||||||||||||||||
| Nequipo-teldat-C2 | 1.3.6.1.4.1.2007.1.1.46 | ||||||||||||||||||||
| Nequipo-operador-remoto | 1.3.6.1.4.1.2007.1.1.47 | ||||||||||||||||||||
| Nequipo-visor | 1.3.6.1.4.1.2007.1.1.48 | ||||||||||||||||||||
| Nequipo-voxnet | 1.3.6.1.4.1.2007.1.1.49 | ||||||||||||||||||||
| Nequipo-dusac32 | 1.3.6.1.4.1.2007.1.1.50 | ||||||||||||||||||||
| Nequipo-novacom-x25 | 1.3.6.1.4.1.2007.1.1.51 | ||||||||||||||||||||
| Nequipo-enaplan | 1.3.6.1.4.1.2007.1.1.52 | ||||||||||||||||||||
| Nequipo-teldat-C3 | 1.3.6.1.4.1.2007.1.1.53 | ||||||||||||||||||||
| Nequipo-atlas-standard | 1.3.6.1.4.1.2007.1.1.56 | ||||||||||||||||||||
| Nequipo-teldat-C2B | 1.3.6.1.4.1.2007.1.1.57 | ||||||||||||||||||||
| Nequipo-teldat-CSW | 1.3.6.1.4.1.2007.1.1.58 | ||||||||||||||||||||
| Nequipo-teldat-C3-1 | 1.3.6.1.4.1.2007.1.1.59 | ||||||||||||||||||||
| Nequipo-teldat-C3B-1 | 1.3.6.1.4.1.2007.1.1.60 | ||||||||||||||||||||
| Nequipo-teldat-C2BM | 1.3.6.1.4.1.2007.1.1.61 | ||||||||||||||||||||
| Nequipo-atlas-basico | 1.3.6.1.4.1.2007.1.1.62 | ||||||||||||||||||||
| Nequipo-teldat-C2i | 1.3.6.1.4.1.2007.1.1.63 | ||||||||||||||||||||
| Nequipo-teldat-C3i | 1.3.6.1.4.1.2007.1.1.64 | ||||||||||||||||||||
| Nequipo-teldat-C3B | 1.3.6.1.4.1.2007.1.1.65 | ||||||||||||||||||||
| Nequipo-teldat-C3G | 1.3.6.1.4.1.2007.1.1.66 | ||||||||||||||||||||
| Nequipo-teldat-C4 | 1.3.6.1.4.1.2007.1.1.67 | ||||||||||||||||||||
| Nequipo-teldat-C4i | 1.3.6.1.4.1.2007.1.1.68 | ||||||||||||||||||||
| Nequipo-teldat-C4B | 1.3.6.1.4.1.2007.1.1.69 | ||||||||||||||||||||
| Nequipo-centrix-sec | 1.3.6.1.4.1.2007.1.1.70 | ||||||||||||||||||||
| Nequipo-centrix-d | 1.3.6.1.4.1.2007.1.1.71 | ||||||||||||||||||||
| Nequipo-teldat-C2-UP | 1.3.6.1.4.1.2007.1.1.72 | ||||||||||||||||||||
| Nequipo-teldat-C6 | 1.3.6.1.4.1.2007.1.1.73 | ||||||||||||||||||||
| Nequipo-centrix-ng | 1.3.6.1.4.1.2007.1.1.74 | ||||||||||||||||||||
| Nequipo-atlas-voxnet | 1.3.6.1.4.1.2007.1.1.75 | ||||||||||||||||||||
| Nequipo-s2 | 1.3.6.1.4.1.2007.1.1.76 | ||||||||||||||||||||
| Nequipo-s4 | 1.3.6.1.4.1.2007.1.1.77 | ||||||||||||||||||||
| Nequipo-s2i | 1.3.6.1.4.1.2007.1.1.78 | ||||||||||||||||||||
| Nequipo-s4i | 1.3.6.1.4.1.2007.1.1.79 | ||||||||||||||||||||
| Nequipo-g2 | 1.3.6.1.4.1.2007.1.1.80 | ||||||||||||||||||||
| Nequipo-g3 | 1.3.6.1.4.1.2007.1.1.81 | ||||||||||||||||||||
| Nequipo-g4 | 1.3.6.1.4.1.2007.1.1.82 | ||||||||||||||||||||
| Nequipo-g2i | 1.3.6.1.4.1.2007.1.1.83 | ||||||||||||||||||||
| Nequipo-g3i | 1.3.6.1.4.1.2007.1.1.84 | ||||||||||||||||||||
| Nequipo-g4i | 1.3.6.1.4.1.2007.1.1.85 | ||||||||||||||||||||
| Nequipo-c1 | 1.3.6.1.4.1.2007.1.1.86 | ||||||||||||||||||||
| Nequipo-c1B | 1.3.6.1.4.1.2007.1.1.87 | ||||||||||||||||||||
| Nequipo-c1i | 1.3.6.1.4.1.2007.1.1.88 | ||||||||||||||||||||
| Nequipo-s1 | 1.3.6.1.4.1.2007.1.1.89 | ||||||||||||||||||||
| Nequipo-s1i | 1.3.6.1.4.1.2007.1.1.90 | ||||||||||||||||||||
| Nequipo-g1 | 1.3.6.1.4.1.2007.1.1.91 | ||||||||||||||||||||
| Nequipo-g1i | 1.3.6.1.4.1.2007.1.1.92 | ||||||||||||||||||||
| Nequipo-g3-lite | 1.3.6.1.4.1.2007.1.1.93 | ||||||||||||||||||||
| Nequipo-C3G-lite | 1.3.6.1.4.1.2007.1.1.94 | ||||||||||||||||||||
| Nequipo-atlas-100 | 1.3.6.1.4.1.2007.1.1.96 | ||||||||||||||||||||
| Nequipo-atlas-300V | 1.3.6.1.4.1.2007.1.1.97 | ||||||||||||||||||||
| Nequipo-c1G | 1.3.6.1.4.1.2007.1.1.98 | ||||||||||||||||||||
| Nequipo-atlas-250 | 1.3.6.1.4.1.2007.1.1.101 | ||||||||||||||||||||
| Nequipo-c4G | 1.3.6.1.4.1.2007.1.1.102 | ||||||||||||||||||||
| Nequipo-atlas-100B | 1.3.6.1.4.1.2007.1.1.103 | ||||||||||||||||||||
| Nequipo-atlas-150 | 1.3.6.1.4.1.2007.1.1.104 | ||||||||||||||||||||
| Nequipo-a2 | 1.3.6.1.4.1.2007.1.1.105 | ||||||||||||||||||||
| Nequipo-a3 | 1.3.6.1.4.1.2007.1.1.106 | ||||||||||||||||||||
| Nequipo-a4 | 1.3.6.1.4.1.2007.1.1.107 | ||||||||||||||||||||
| Nequipo-a2i | 1.3.6.1.4.1.2007.1.1.108 | ||||||||||||||||||||
| Nequipo-a3i | 1.3.6.1.4.1.2007.1.1.109 | ||||||||||||||||||||
| Nequipo-a4i | 1.3.6.1.4.1.2007.1.1.110 | ||||||||||||||||||||
| Nequipo-a1 | 1.3.6.1.4.1.2007.1.1.111 | ||||||||||||||||||||
| Nequipo-a1i | 1.3.6.1.4.1.2007.1.1.112 | ||||||||||||||||||||
| Nequipo-g4-cdma | 1.3.6.1.4.1.2007.1.1.114 | ||||||||||||||||||||
| Nequipo-g4i-cdma | 1.3.6.1.4.1.2007.1.1.115 | ||||||||||||||||||||
| Nequipo-g3-cdma | 1.3.6.1.4.1.2007.1.1.116 | ||||||||||||||||||||
| Nequipo-g3i-cdma | 1.3.6.1.4.1.2007.1.1.117 | ||||||||||||||||||||
| Nequipo-g1-cdma | 1.3.6.1.4.1.2007.1.1.118 | ||||||||||||||||||||
| Nequipo-g1i-cdma | 1.3.6.1.4.1.2007.1.1.119 | ||||||||||||||||||||
| Nequipo-c1plus | 1.3.6.1.4.1.2007.1.1.122 | ||||||||||||||||||||
| Nequipo-c1iplus | 1.3.6.1.4.1.2007.1.1.123 | ||||||||||||||||||||
| Nequipo-atlas-50 | 1.3.6.1.4.1.2007.1.1.126 | ||||||||||||||||||||
| Nequipo-g4plus | 1.3.6.1.4.1.2007.1.1.127 | ||||||||||||||||||||
| Nequipo-g3plus | 1.3.6.1.4.1.2007.1.1.128 | ||||||||||||||||||||
| Nequipo-g1plus | 1.3.6.1.4.1.2007.1.1.129 | ||||||||||||||||||||
| Nequipo-g4iplus | 1.3.6.1.4.1.2007.1.1.130 | ||||||||||||||||||||
| Nequipo-g3iplus | 1.3.6.1.4.1.2007.1.1.131 | ||||||||||||||||||||
| Nequipo-g1iplus | 1.3.6.1.4.1.2007.1.1.132 | ||||||||||||||||||||
| Nequipo-atlas-250SW | 1.3.6.1.4.1.2007.1.1.133 | ||||||||||||||||||||
| Nequipo-atlas-150SW | 1.3.6.1.4.1.2007.1.1.134 | ||||||||||||||||||||
| Nequipo-atlas-50SW | 1.3.6.1.4.1.2007.1.1.135 | ||||||||||||||||||||
| Nequipo-vyda-1M | 1.3.6.1.4.1.2007.1.1.136 | ||||||||||||||||||||
| Nequipo-vyda-2M | 1.3.6.1.4.1.2007.1.1.137 | ||||||||||||||||||||
| Nequipo-vyda-3M | 1.3.6.1.4.1.2007.1.1.138 | ||||||||||||||||||||
| Nequipo-atlas-300 | 1.3.6.1.4.1.2007.1.1.139 | ||||||||||||||||||||
| Nequipo-atlas-152 | 1.3.6.1.4.1.2007.1.1.140 | ||||||||||||||||||||
| Nequipo-vyda-compact | 1.3.6.1.4.1.2007.1.1.141 | ||||||||||||||||||||
| Nequipo-C8plus | 1.3.6.1.4.1.2007.1.1.142 | ||||||||||||||||||||
| Nequipo-C8iplus | 1.3.6.1.4.1.2007.1.1.143 | ||||||||||||||||||||
| Nequipo-C9plus | 1.3.6.1.4.1.2007.1.1.144 | ||||||||||||||||||||
| Nequipo-C9iplus | 1.3.6.1.4.1.2007.1.1.145 | ||||||||||||||||||||
| Nequipo-atlas-360 | 1.3.6.1.4.1.2007.1.1.146 | ||||||||||||||||||||
| Nequipo-c1plus-SW | 1.3.6.1.4.1.2007.1.1.147 | ||||||||||||||||||||
| Nequipo-c1a | 1.3.6.1.4.1.2007.1.1.148 | ||||||||||||||||||||
| Nequipo-s1a | 1.3.6.1.4.1.2007.1.1.149 | ||||||||||||||||||||
| Nequipo-g1a | 1.3.6.1.4.1.2007.1.1.150 | ||||||||||||||||||||
| Nequipo-g1a-cdma | 1.3.6.1.4.1.2007.1.1.151 | ||||||||||||||||||||
| Nequipo-a1a | 1.3.6.1.4.1.2007.1.1.152 | ||||||||||||||||||||
| Nequipo-c2a | 1.3.6.1.4.1.2007.1.1.155 | ||||||||||||||||||||
| Nequipo-s2a | 1.3.6.1.4.1.2007.1.1.156 | ||||||||||||||||||||
| Nequipo-g2a | 1.3.6.1.4.1.2007.1.1.157 | ||||||||||||||||||||
| Nequipo-a2a | 1.3.6.1.4.1.2007.1.1.158 | ||||||||||||||||||||
| Nequipo-c4a | 1.3.6.1.4.1.2007.1.1.159 | ||||||||||||||||||||
| Nequipo-s4a | 1.3.6.1.4.1.2007.1.1.160 | ||||||||||||||||||||
| Nequipo-g4a | 1.3.6.1.4.1.2007.1.1.161 | ||||||||||||||||||||
| Nequipo-g4a-cdma | 1.3.6.1.4.1.2007.1.1.162 | ||||||||||||||||||||
| Nequipo-a4a | 1.3.6.1.4.1.2007.1.1.163 | ||||||||||||||||||||
| Nequipo-cirus | 1.3.6.1.4.1.2007.1.1.165 | ||||||||||||||||||||
| Nequipo-h1 | 1.3.6.1.4.1.2007.1.1.166 | ||||||||||||||||||||
| Nequipo-atlas-260 | 1.3.6.1.4.1.2007.1.1.167 | ||||||||||||||||||||
| Nequipo-atlas-160 | 1.3.6.1.4.1.2007.1.1.168 | ||||||||||||||||||||
| Nequipo-vyda-4M | 1.3.6.1.4.1.2007.1.1.169 | ||||||||||||||||||||
| Nequipo-t200g | 1.3.6.1.4.1.2007.1.1.170 | ||||||||||||||||||||
| Nequipo-h1-auto | 1.3.6.1.4.1.2007.1.1.171 | ||||||||||||||||||||
| Nequipo-g1n | 1.3.6.1.4.1.2007.1.1.172 | ||||||||||||||||||||
| Nequipo-v1 | 1.3.6.1.4.1.2007.1.1.173 | ||||||||||||||||||||
| Nequipo-c1plusl | 1.3.6.1.4.1.2007.1.1.174 | ||||||||||||||||||||
| Nequipo-h4 | 1.3.6.1.4.1.2007.1.1.175 | ||||||||||||||||||||
| Nequipo-t200 | 1.3.6.1.4.1.2007.1.1.176 | ||||||||||||||||||||
| Nequipo-h1plus | 1.3.6.1.4.1.2007.1.1.177 | ||||||||||||||||||||
| Nequipo-regesta-rp81 | 1.3.6.1.4.1.2007.1.1.178 | ||||||||||||||||||||
| Nequipo-regesta-rp82 | 1.3.6.1.4.1.2007.1.1.179 | ||||||||||||||||||||
| Nequipo-regesta-1 | 1.3.6.1.4.1.2007.1.1.180 | ||||||||||||||||||||
| Nequipo-f1plus | 1.3.6.1.4.1.2007.1.1.181 | ||||||||||||||||||||
| Nequipo-l1plus | 1.3.6.1.4.1.2007.1.1.183 | ||||||||||||||||||||
| Nequipo-regesta-rp61er | 1.3.6.1.4.1.2007.1.1.184 | ||||||||||||||||||||
| Nequipo-regesta-rp62er | 1.3.6.1.4.1.2007.1.1.185 | ||||||||||||||||||||
| Nequipo-3geplus | 1.3.6.1.4.1.2007.1.1.186 | ||||||||||||||||||||
| Nequipo-atlas-60 | 1.3.6.1.4.1.2007.1.1.187 | ||||||||||||||||||||
| Nequipo-3geplus-cdma | 1.3.6.1.4.1.2007.1.1.188 | ||||||||||||||||||||
| Nequipo-h1auto-plus | 1.3.6.1.4.1.2007.1.1.189 | ||||||||||||||||||||
| Nequipo-k | 1.3.6.1.4.1.2007.1.1.190 | ||||||||||||||||||||
| Nequipo-v | 1.3.6.1.4.1.2007.1.1.191 | ||||||||||||||||||||
| Nequipo-connect-104 | 1.3.6.1.4.1.2007.1.1.192 | ||||||||||||||||||||
| Nequipo-h1rail | 1.3.6.1.4.1.2007.1.1.193 | ||||||||||||||||||||
| Nequipo-kf | 1.3.6.1.4.1.2007.1.1.194 | ||||||||||||||||||||
| Nequipo-m1 | 1.3.6.1.4.1.2007.1.1.199 | ||||||||||||||||||||
| Nequipo-m1f | 1.3.6.1.4.1.2007.1.1.200 | ||||||||||||||||||||
| Nequipo-4Ge | 1.3.6.1.4.1.2007.1.1.201 | ||||||||||||||||||||
| Nrouter-oa5710v | 1.3.6.1.4.1.2007.1.1.202 | ||||||||||||||||||||
| Nrouter-oa5720 | 1.3.6.1.4.1.2007.1.1.203 | ||||||||||||||||||||
| Nrouter-oa5840 | 1.3.6.1.4.1.2007.1.1.204 | ||||||||||||||||||||
| Nrouter-oa5850 | 1.3.6.1.4.1.2007.1.1.205 | ||||||||||||||||||||
| Nrouter-oa5725r61er | 1.3.6.1.4.1.2007.1.1.206 | ||||||||||||||||||||
| Nrouter-oa5725r62er | 1.3.6.1.4.1.2007.1.1.207 | ||||||||||||||||||||
| Nrouter-oa5725a3g | 1.3.6.1.4.1.2007.1.1.208 | ||||||||||||||||||||
| Nrouter-oa5725alte | 1.3.6.1.4.1.2007.1.1.209 | ||||||||||||||||||||
| Nrouter-esrwwanenabler | 1.3.6.1.4.1.2007.1.1.210 | ||||||||||||||||||||
| Nequipo-connect-104-v | 1.3.6.1.4.1.2007.1.1.211 | ||||||||||||||||||||
| Nequipo-connect-104-kf | 1.3.6.1.4.1.2007.1.1.212 | ||||||||||||||||||||
| Nequipo-connect-4ge | 1.3.6.1.4.1.2007.1.1.213 | ||||||||||||||||||||
| Nequipo-bintecrsc | 1.3.6.1.4.1.2007.1.1.214 | ||||||||||||||||||||
| Nequipo-regesta-lite | 1.3.6.1.4.1.2007.1.1.215 | ||||||||||||||||||||
| Nequipo-bintecrvc | 1.3.6.1.4.1.2007.1.1.216 | ||||||||||||||||||||
| Nequipo-H2auto | 1.3.6.1.4.1.2007.1.1.217 | ||||||||||||||||||||
| Nequipo-iM8 | 1.3.6.1.4.1.2007.1.1.219 | ||||||||||||||||||||
| Nequipo-iM8-Plus | 1.3.6.1.4.1.2007.1.1.220 | ||||||||||||||||||||
| Nequipo-H2auto-Plus | 1.3.6.1.4.1.2007.1.1.221 | ||||||||||||||||||||
| Nequipo-regesta-plc | 1.3.6.1.4.1.2007.1.1.222 | ||||||||||||||||||||
| Nequipo-Atlas-i70 | 1.3.6.1.4.1.2007.1.1.223 | ||||||||||||||||||||
| Nequipo-Atlas-i70-Plus | 1.3.6.1.4.1.2007.1.1.224 | ||||||||||||||||||||
| Nequipo-h2rail-lite | 1.3.6.1.4.1.2007.1.1.225 | ||||||||||||||||||||
| Nequipo-h2rail-lite2 | 1.3.6.1.4.1.2007.1.1.226 | ||||||||||||||||||||
| Nequipo-h2rail | 1.3.6.1.4.1.2007.1.1.227 | ||||||||||||||||||||
| Nequipo-regesta-comp-plc | 1.3.6.1.4.1.2007.1.1.229 | ||||||||||||||||||||
| Ntelstatus | 1.3.6.1.4.1.2007.1.2 | ||||||||||||||||||||
| NtelAdminStatusSystem | 1.3.6.1.4.1.2007.1.2.1 | ||||||||||||||||||||
| StelAdminStatusSystemCode | 1.3.6.1.4.1.2007.1.2.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Product identifier determined by Teldat identifiers table.
| |||||||||||||||||||||
| StelAdminStatusSystemSwLicLev | 1.3.6.1.4.1.2007.1.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Main level of software licence. This variable indicates the specific family where the product is included. The value 0 is the default value taken when the real value is not associated to any licence recognized or supported. The possible values for this variable and their meaning are: (1) Teldat C. (2) Atlas. (3) Visornet. (4) Teldat S. (5) Teldat G. (6) Atlas 2G. (7) Atlas 150. (8) Teldat A. (9) Atlas 50. (10) Atlas 300. (11) Atlas 152. (12) Teldat C1+. (13) Teldat C8+. (14) Teldat C9+. (15) Atlas 360. (16) Teldat H. (17) Atlas 260. (18) Atlas 160. (19) Teldat T200G. (20) Teldat H1 Auto. (21) Teldat G1N. (22) Teldat C1+L. (23) Teldat V1. (24) Teldat H4 or L1+. (25) Teldat T200. (26) Teldat H1+, Teldat F1+ or Teldat 3Ge+. (27) RegestaPro-ER. (28) Atlas 60. (29) Teldat H1 Auto.+ (30) Teldat V (31) Teldat Connect 104 (32) Teldat K (33) Teldat H Rail Family (34) Teldat M1 (35) Teldat 4Ge (36) Teldat Connect 104V (37) Teldat Connect 104KF (38) Teldat Connect 4Ge (39) Teldat H2 Auto. (40) Teldat H2 Auto Plus. (41) Teldat H2 Rail. If the value of this variable is teldatC (1), atlas (2), visornet (3), teldatS (4), teldatG (5), atlas2g (5), atlas150 (7), teldatA (8) or atlas50 (9) it will be necessary to consider also the value of the next variable to completely determine the type of the accessed product. In any other case, different products can take the same value for this level of software licence and second level of software licence will be always 0, so it will be not possible to distinguish them through their licence.
| |||||||||||||||||||||
| StelAdminStatusSystemSwLicSub | 1.3.6.1.4.1.2007.1.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Second level of software licence. This variable is used to know the family funcionality group inside the family indicated with the previous value. The value 0 is the only value taken by this variable in 360-based routers, and also the default value taken when the real value is not associated to any licence recognized or supported. It is necessary to consider also the value of the previous variable to completely determine the type of the product accessed. | |||||||||||||||||||||
| StelAdminStatusSystemNumSerie | 1.3.6.1.4.1.2007.1.2.1.4 | INTEGER | RO | mandatory | 1144 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory Series number of the node. Example values from LibreNMS test devices
| |||||||||||||||||||||
| StelAdminStatusSystemPcbType | 1.3.6.1.4.1.2007.1.2.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Board type. | |||||||||||||||||||||
| StelAdminStatusSystemAppVersion | 1.3.6.1.4.1.2007.1.2.1.6 | DisplayString | RO | mandatory | 11.01.00.20.18 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory Version of the application running at the moment in the system. Example values from LibreNMS test devices
| |||||||||||||||||||||
| StelAdminStatusSystemBootVersion | 1.3.6.1.4.1.2007.1.2.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Version of the system eprom software. | |||||||||||||||||||||
| StelAdminStatusSystemClock | 1.3.6.1.4.1.2007.1.2.1.8 | OCTET STRING (SIZE (8)) | RW | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (8)) · read-write · mandatory Node time and date. 8 Bytes EBCDIC show respectively seconds, minutes, padding, day, month, week day (monday, etc) and year. | |||||||||||||||||||||
| StelAdminStatusSystemBoardType | 1.3.6.1.4.1.2007.1.2.1.9 | INTEGER | RO | mandatory | tldt-m1(312) | ||||||||||||||||
scalar · INTEGER · read-only · mandatory Board type.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| StelAdminStatusSystemBoardRevision | 1.3.6.1.4.1.2007.1.2.1.10 | INTEGER | RO | mandatory | 2 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory Board revision. Example values from LibreNMS test devices
| |||||||||||||||||||||
| StelAdminStatusSystemSmartCard | 1.3.6.1.4.1.2007.1.2.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This variable indicates whether Smart Card controler is installed. Possible values: no(0), yes(1).
| |||||||||||||||||||||
| TtelAdminStatusLedsTable | 1.3.6.1.4.1.2007.1.2.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The table telAdminStatusLedsTable contains information about leds. | |||||||||||||||||||||
| RtelAdminStatusLedsEntry | 1.3.6.1.4.1.2007.1.2.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each entry contains the number and state of each led.
| |||||||||||||||||||||
| CtelAdminStatusLedNum | 1.3.6.1.4.1.2007.1.2.2.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Led identifier number.
| |||||||||||||||||||||
| CtelAdminStatusLedStatus | 1.3.6.1.4.1.2007.1.2.2.1.2 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Led state.
| |||||||||||||||||||||
| TtelAdminStatusBugsTable | 1.3.6.1.4.1.2007.1.2.3 | NA | obsolete | ||||||||||||||||||
table · not-accessible · obsolete The table named telAdminStatusBugsTable gives information about the system bug messages. | |||||||||||||||||||||
| RtelAdminStatusBugsEntry | 1.3.6.1.4.1.2007.1.2.3.1 | NA | obsolete | ||||||||||||||||||
row · not-accessible · obsolete Each entry contains the message number (1 is the last) and the string of the corresponding message.
| |||||||||||||||||||||
| CtelAdminStatusBugNum | 1.3.6.1.4.1.2007.1.2.3.1.1 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete Bug number. | |||||||||||||||||||||
| CtelAdminStatusBugMsg | 1.3.6.1.4.1.2007.1.2.3.1.2 | DisplayString | RO | obsolete | |||||||||||||||||
column · DisplayString · read-only · obsolete Bug text. | |||||||||||||||||||||
| StelAdminStatusBugsClear | 1.3.6.1.4.1.2007.1.2.4 | INTEGER | RW | obsolete | |||||||||||||||||
scalar · INTEGER · read-write · obsolete In a writing operation, 1 resets the number of bugs stored by the system, in a reading operation it is always 0.
| |||||||||||||||||||||
| StelAdminStatusReload | 1.3.6.1.4.1.2007.1.2.5 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory In a writing operation 1 resets the system (Reset Hard), In a reading operation, 0 shows unknown output from the last set operation, 2 shows the set operation succeded and 3 shows the last set operation failed.
| |||||||||||||||||||||
| StelAdminStatusRestart | 1.3.6.1.4.1.2007.1.2.6 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory In a writing operation 1 resets the system (Reset Soft), In a reading operation, 0 shows the unknown output from the last set operation, 2 shows the set operation succeded and 3 shows the last set operation failed.
| |||||||||||||||||||||
| StelAdminStatusSaveConfig | 1.3.6.1.4.1.2007.1.2.7 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory In a writing operation 1 saves to RAM the current system configuration. In a reading operation, 0 shows unknown output from the last set operation, 2 shows the set operation succeded and 3 shows the last set operation failed.
| |||||||||||||||||||||
| NtelAdminStatusSram | 1.3.6.1.4.1.2007.1.2.8 | ||||||||||||||||||||
| TtelAdminStatusSramRecordTable | 1.3.6.1.4.1.2007.1.2.8.1 | NA | obsolete | ||||||||||||||||||
table · not-accessible · obsolete The table telAdminStatusSramRecordTable contains information about non volatil or SRAM system memory. This memory consists of records that are instances of concrete types and subtypes. | |||||||||||||||||||||
| RtelAdminStatusSramRecordEntry | 1.3.6.1.4.1.2007.1.2.8.1.1 | NA | obsolete | ||||||||||||||||||
row · not-accessible · obsolete Each entry gives information about type, subtype, instance and specific object in SRAM. | |||||||||||||||||||||
| CsramRecordType | 1.3.6.1.4.1.2007.1.2.8.1.1.1 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete SRAM register type. | |||||||||||||||||||||
| CsramRecordSubtype | 1.3.6.1.4.1.2007.1.2.8.1.1.2 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete SRAM register subtype. | |||||||||||||||||||||
| CsramRecordInstance | 1.3.6.1.4.1.2007.1.2.8.1.1.3 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete Instance of the SRAM register. | |||||||||||||||||||||
| CsramRecordItem | 1.3.6.1.4.1.2007.1.2.8.1.1.4 | Opaque | RW | obsolete | |||||||||||||||||
column · Opaque · read-write · obsolete Specific SRAM register. Since registers may have different sizes depending on the data type of the object (type and subtype), the writing operations only must be performed if the data type of each object (type and subtype) is known. In case data types were not similar, the final configuration could result erroneous. | |||||||||||||||||||||
| NtelAdminStatusSRE | 1.3.6.1.4.1.2007.1.2.9 | ||||||||||||||||||||
| TtelAdminStatusSRESubRecordTable | 1.3.6.1.4.1.2007.1.2.9.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The table telAdminStatusSRESubRecordTable contains information about the event subsystem. | |||||||||||||||||||||
| RtelAdminStatusSRESubRecordEntry | 1.3.6.1.4.1.2007.1.2.9.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each entry contains information about identifier, short name, long name, level, event number and if the concrete subsystem is enabled or not for traces, syslog messages and/or SNMP traps.
| |||||||||||||||||||||
| CsreSubId | 1.3.6.1.4.1.2007.1.2.9.1.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Subsystem identifier. | |||||||||||||||||||||
| CsreSubShortName | 1.3.6.1.4.1.2007.1.2.9.1.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Subsystem short name. | |||||||||||||||||||||
| CsreSubLongName | 1.3.6.1.4.1.2007.1.2.9.1.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Subsystem long name. | |||||||||||||||||||||
| CsreSubNumEvent | 1.3.6.1.4.1.2007.1.2.9.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Number of subsystem defined events. | |||||||||||||||||||||
| CsreSubTraceLvlConf | 1.3.6.1.4.1.2007.1.2.9.1.1.5 | INTEGER (0..65535) | RW | mandatory | |||||||||||||||||
column · INTEGER (0..65535) · read-write · mandatory This mask defines the way the subsystem is enabled for traces. The mask´s meaning is: (UI-ERROR,0x0001); (CI-ERROR,0x0002); (UE-ERROR,0x0004); (CE-ERROR,0x0008); (ERROR,0x000F); (U-INFO,0x0010); (C-INFO,0x0020); (INFO,0x0030); (P-TRACE,0x0100); (U-TRACE,0x0200); (C-TRACE,0x0400) (TRACE,0x0700); (STANDARD,0x001F); (ALWAYS,0x8000); (ALL,0xFFFF) | |||||||||||||||||||||
| CsreSubSyslogLvlConf | 1.3.6.1.4.1.2007.1.2.9.1.1.6 | INTEGER (0..65535) | RW | mandatory | |||||||||||||||||
column · INTEGER (0..65535) · read-write · mandatory This mask defines the way the subsystem is enabled for syslog messages. The mask´s meaning is: (UI-ERROR,0x0001); (CI-ERROR,0x0002); (UE-ERROR,0x0004); (CE-ERROR,0x0008); (ERROR,0x000F); (U-INFO,0x0010); (C-INFO,0x0020); (INFO,0x0030); (P-TRACE,0x0100); (U-TRACE,0x0200); (C-TRACE,0x0400) (TRACE,0x0700); (STANDARD,0x001F); (ALWAYS,0x8000); (ALL,0xFFFF) | |||||||||||||||||||||
| CsreSubTrapLvlConf | 1.3.6.1.4.1.2007.1.2.9.1.1.7 | INTEGER (0..65535) | RW | mandatory | |||||||||||||||||
column · INTEGER (0..65535) · read-write · mandatory This mask defines the way the subsystem is enabled for SNMP traps. The mask´s meaning is: (UI-ERROR,0x0001); (CI-ERROR,0x0002); (UE-ERROR,0x0004); (CE-ERROR,0x0008); (ERROR,0x000F); (U-INFO,0x0010); (C-INFO,0x0020); (INFO,0x0030); (P-TRACE,0x0100); (U-TRACE,0x0200); (C-TRACE,0x0400) (TRACE,0x0700); (STANDARD,0x001F); (ALWAYS,0x8000); (ALL,0xFFFF) | |||||||||||||||||||||
| CsreSubTrap1LvlConf | 1.3.6.1.4.1.2007.1.2.9.1.1.8 | INTEGER (0..65535) | RW | mandatory | |||||||||||||||||
column · INTEGER (0..65535) · read-write · mandatory This mask defines the way the subsystem is enabled for SNMP traps group 1. The mask´s meaning is: (UI-ERROR,0x0001); (CI-ERROR,0x0002); (UE-ERROR,0x0004); (CE-ERROR,0x0008); (ERROR,0x000F); (U-INFO,0x0010); (C-INFO,0x0020); (INFO,0x0030); (P-TRACE,0x0100); (U-TRACE,0x0200); (C-TRACE,0x0400) (TRACE,0x0700); (STANDARD,0x001F); (ALWAYS,0x8000); (ALL,0xFFFF) | |||||||||||||||||||||
| CsreSubTrap2LvlConf | 1.3.6.1.4.1.2007.1.2.9.1.1.9 | INTEGER (0..65535) | RW | mandatory | |||||||||||||||||
column · INTEGER (0..65535) · read-write · mandatory This mask defines the way the subsystem is enabled for SNMP traps group 2. The mask´s meaning is: (UI-ERROR,0x0001); (CI-ERROR,0x0002); (UE-ERROR,0x0004); (CE-ERROR,0x0008); (ERROR,0x000F); (U-INFO,0x0010); (C-INFO,0x0020); (INFO,0x0030); (P-TRACE,0x0100); (U-TRACE,0x0200); (C-TRACE,0x0400) (TRACE,0x0700); (STANDARD,0x001F); (ALWAYS,0x8000); (ALL,0xFFFF) | |||||||||||||||||||||
| CsreSubTrap3LvlConf | 1.3.6.1.4.1.2007.1.2.9.1.1.10 | INTEGER (0..65535) | RW | mandatory | |||||||||||||||||
column · INTEGER (0..65535) · read-write · mandatory This mask defines the way the subsystem is enabled for SNMP traps group 3. The mask´s meaning is: (UI-ERROR,0x0001); (CI-ERROR,0x0002); (UE-ERROR,0x0004); (CE-ERROR,0x0008); (ERROR,0x000F); (U-INFO,0x0010); (C-INFO,0x0020); (INFO,0x0030); (P-TRACE,0x0100); (U-TRACE,0x0200); (C-TRACE,0x0400) (TRACE,0x0700); (STANDARD,0x001F); (ALWAYS,0x8000); (ALL,0xFFFF) | |||||||||||||||||||||
| CsreSubTrap4LvlConf | 1.3.6.1.4.1.2007.1.2.9.1.1.11 | INTEGER (0..65535) | RW | mandatory | |||||||||||||||||
column · INTEGER (0..65535) · read-write · mandatory This mask defines the way the subsystem is enabled for SNMP traps group 4. The mask´s meaning is: (UI-ERROR,0x0001); (CI-ERROR,0x0002); (UE-ERROR,0x0004); (CE-ERROR,0x0008); (ERROR,0x000F); (U-INFO,0x0010); (C-INFO,0x0020); (INFO,0x0030); (P-TRACE,0x0100); (U-TRACE,0x0200); (C-TRACE,0x0400) (TRACE,0x0700); (STANDARD,0x001F); (ALWAYS,0x8000); (ALL,0xFFFF) | |||||||||||||||||||||
| TtelAdminStatusSREEventRecordTable | 1.3.6.1.4.1.2007.1.2.9.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The table telAdminStatusSREEventRecordTable contains information about the subsystem events. | |||||||||||||||||||||
| RtelAdminStatusSREEventRecordEntry | 1.3.6.1.4.1.2007.1.2.9.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each entry contains information about the subsystem identifier, event identifier in the subsystem, mask of the event message, event level, times the event occured, current enable mask and configured enable mask.
| |||||||||||||||||||||
| CsreEvnSubId | 1.3.6.1.4.1.2007.1.2.9.2.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, it is similar to the subsystem identifier that exists in the subsystem table. | |||||||||||||||||||||
| CsreEvnEvnId | 1.3.6.1.4.1.2007.1.2.9.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreEvnMsg | 1.3.6.1.4.1.2007.1.2.9.2.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Event message mask. | |||||||||||||||||||||
| CsreEvnLvl | 1.3.6.1.4.1.2007.1.2.9.2.1.4 | INTEGER (0..65535) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..65535) · read-only · mandatory Message level. It is a mask with the following meaning: (UI-ERROR,0x0001); (CI-ERROR,0x0002); (UE-ERROR,0x0004); (CE-ERROR,0x0008); (ERROR,0x000F); (U-INFO,0x0010); (C-INFO,0x0020); (INFO,0x0030); (P-TRACE,0x0100); (U-TRACE,0x0200); (C-TRACE,0x0400) (TRACE,0x0700); (STANDARD,0x001F); (ALWAYS,0x8000); (ALL,0xFFFF) | |||||||||||||||||||||
| CsreEvnMeter | 1.3.6.1.4.1.2007.1.2.9.2.1.5 | Counter | RO | mandatory | |||||||||||||||||
column · Counter · read-only · mandatory Times the event has ocurred since the last restart/reload. The meaning of the mask is: (UI-ERROR,0x0001); (CI-ERROR,0x0002); (UE-ERROR,0x0004); (CE-ERROR,0x0008); (ERROR,0x000F); (U-INFO,0x0010); (C-INFO,0x0020); (INFO,0x0030); (P-TRACE,0x0100); (U-TRACE,0x0200); (C-TRACE,0x0400) (TRACE,0x0700); (STANDARD,0x001F); (ALWAYS,0x8000); (ALL,0xFFFF) | |||||||||||||||||||||
| CsreEvnStatusAct | 1.3.6.1.4.1.2007.1.2.9.2.1.6 | INTEGER (0..255) | RW | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-write · mandatory The mask defines the way the event is enabled at the moment. The meaning of the mask is: (for traces,0x01); (for syslog messages, 0x02); (for SNMP traps, 0x04); (all, 0x07); (for specific traps with correspondence with generic traps, 0x08); (disabled, 0x00) | |||||||||||||||||||||
| CsreEvnStatusCon | 1.3.6.1.4.1.2007.1.2.9.2.1.7 | INTEGER (0..255) | RW | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-write · mandatory The mask defines the way the event is enabled in configuration at the moment. The meaning of the mask is: (for traces,0x01); (for syslog messages, 0x02); (for SNMP traps, 0x04); (all, 0x07); (disabled, 0x00) | |||||||||||||||||||||
| TtelAdminStatusSREGroupRecordTable | 1.3.6.1.4.1.2007.1.2.9.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The table telAdminStatusSREGroupRecordTable contains information about defined sets of events. | |||||||||||||||||||||
| RtelAdminStatusSREGroupRecordEntry | 1.3.6.1.4.1.2007.1.2.9.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each entry contains information about the group identifier, group name, enable mask, and the event and subsystem identifier for each of the 20 possible events of the group.
| |||||||||||||||||||||
| CsreGrpId | 1.3.6.1.4.1.2007.1.2.9.3.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Group identifier. | |||||||||||||||||||||
| CsreGrpName | 1.3.6.1.4.1.2007.1.2.9.3.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Group name. | |||||||||||||||||||||
| CsreGrpStatusCon | 1.3.6.1.4.1.2007.1.2.9.3.1.3 | INTEGER (0..255) | RW | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-write · mandatory The mask defines the way the group is enabled at the moment. The meaning of the mask is: (for traces,0x01); (for syslog messages, 0x02); (for SNMP traps, 0x04); (all, 0x07); (disabled, 0x00) | |||||||||||||||||||||
| CsreGrpGrpSub1Id | 1.3.6.1.4.1.2007.1.2.9.3.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that apperars in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn1Id | 1.3.6.1.4.1.2007.1.2.9.3.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub2Id | 1.3.6.1.4.1.2007.1.2.9.3.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn2Id | 1.3.6.1.4.1.2007.1.2.9.3.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub3Id | 1.3.6.1.4.1.2007.1.2.9.3.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn3Id | 1.3.6.1.4.1.2007.1.2.9.3.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub4Id | 1.3.6.1.4.1.2007.1.2.9.3.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn4Id | 1.3.6.1.4.1.2007.1.2.9.3.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub5Id | 1.3.6.1.4.1.2007.1.2.9.3.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn5Id | 1.3.6.1.4.1.2007.1.2.9.3.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub6Id | 1.3.6.1.4.1.2007.1.2.9.3.1.14 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn6Id | 1.3.6.1.4.1.2007.1.2.9.3.1.15 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub7Id | 1.3.6.1.4.1.2007.1.2.9.3.1.16 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn7Id | 1.3.6.1.4.1.2007.1.2.9.3.1.17 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub8Id | 1.3.6.1.4.1.2007.1.2.9.3.1.18 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn8Id | 1.3.6.1.4.1.2007.1.2.9.3.1.19 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub9Id | 1.3.6.1.4.1.2007.1.2.9.3.1.20 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn9Id | 1.3.6.1.4.1.2007.1.2.9.3.1.21 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub10Id | 1.3.6.1.4.1.2007.1.2.9.3.1.22 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn10Id | 1.3.6.1.4.1.2007.1.2.9.3.1.23 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub11Id | 1.3.6.1.4.1.2007.1.2.9.3.1.24 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn11Id | 1.3.6.1.4.1.2007.1.2.9.3.1.25 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub12Id | 1.3.6.1.4.1.2007.1.2.9.3.1.26 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn12Id | 1.3.6.1.4.1.2007.1.2.9.3.1.27 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub13Id | 1.3.6.1.4.1.2007.1.2.9.3.1.28 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn13Id | 1.3.6.1.4.1.2007.1.2.9.3.1.29 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub14Id | 1.3.6.1.4.1.2007.1.2.9.3.1.30 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn14Id | 1.3.6.1.4.1.2007.1.2.9.3.1.31 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub15Id | 1.3.6.1.4.1.2007.1.2.9.3.1.32 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn15Id | 1.3.6.1.4.1.2007.1.2.9.3.1.33 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub16Id | 1.3.6.1.4.1.2007.1.2.9.3.1.34 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn16Id | 1.3.6.1.4.1.2007.1.2.9.3.1.35 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub17Id | 1.3.6.1.4.1.2007.1.2.9.3.1.36 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn17Id | 1.3.6.1.4.1.2007.1.2.9.3.1.37 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub18Id | 1.3.6.1.4.1.2007.1.2.9.3.1.38 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn18Id | 1.3.6.1.4.1.2007.1.2.9.3.1.39 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub19Id | 1.3.6.1.4.1.2007.1.2.9.3.1.40 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn19Id | 1.3.6.1.4.1.2007.1.2.9.3.1.41 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| CsreGrpGrpSub20Id | 1.3.6.1.4.1.2007.1.2.9.3.1.42 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Identifier of the subsystem the event belongs to, similar to the subsystem identifier that appears in the subsystems table. | |||||||||||||||||||||
| CsreGrpGrpEvn20Id | 1.3.6.1.4.1.2007.1.2.9.3.1.43 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Event identifier in the subsystem. | |||||||||||||||||||||
| StelAdminStatusSREClearConf | 1.3.6.1.4.1.2007.1.2.9.4 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory This variable deletes the events configuration of the router. If a set operation is performed we can select without-configuration (1) to delete the events configuration. The configuration takes effect after reseting the router.
| |||||||||||||||||||||
| TtelAdminStatusIfTable | 1.3.6.1.4.1.2007.1.2.10 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The table telAdminStatusifTable contains specific information about Teldat interfaces. | |||||||||||||||||||||
| RtelAdminStatusIfEntry | 1.3.6.1.4.1.2007.1.2.10.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each entry gives information about the interface type, connector type, and a description of the hardware type for each interface. | |||||||||||||||||||||
| CtelAdminStatusIfIndex | 1.3.6.1.4.1.2007.1.2.10.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Interface index. | |||||||||||||||||||||
| CtelAdminStatusIfType | 1.3.6.1.4.1.2007.1.2.10.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Teldat Specific Interface Type.
| |||||||||||||||||||||
| CtelAdminStatusIfCon | 1.3.6.1.4.1.2007.1.2.10.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Connector related to the interface.
| |||||||||||||||||||||
| CtelAdminStatusIfHdw | 1.3.6.1.4.1.2007.1.2.10.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Description of the hardware related to the interface. | |||||||||||||||||||||
| StelAdminStatusEthTime | 1.3.6.1.4.1.2007.1.2.11 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Date and time Ethernet statistics were updated for last time. | |||||||||||||||||||||
| StelAdminConfActDev | 1.3.6.1.4.1.2007.1.2.12 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Active Device. Device used to read and write configuration files.
| |||||||||||||||||||||
| StelAdminConfConfSavedDev | 1.3.6.1.4.1.2007.1.2.13 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Device where the last configuration has been saved.
| |||||||||||||||||||||
| StelAdminStatusConfirmConfig | 1.3.6.1.4.1.2007.1.2.14 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory In a writing operation 1 confirms the current configuration. In a writing operation 0 rejects the current test configuration restarting the device with the previous configuration. In a reading operation, 0 shows that the current configuration has been confirmed, 1 shows that the current configuration has not been confirmed yet (therefore it is a testing configuration) and it is active the old ones, 2 shows that the current configuration has not been confirmed yet (therefore it is a testing configuration) and it is active the new ones, 3 shows that the old configuration has been recovered and it is confirmed and active, 4 shows unknown state
| |||||||||||||||||||||
| StelAdminStatusConfirmEnabled | 1.3.6.1.4.1.2007.1.2.15 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory In a writing operation 1 enables the need to confirm the saved configuration. In a writing operation 0 disables the need to confirm the newly saved configurations. In a reading operation, 0 shows that the need to confirm the saved configurations is disabled. In a reading operation, 1 shows that the need to confirm the saved configurations is enabled.
| |||||||||||||||||||||
| StelAdminStatusTimeoutConfirm | 1.3.6.1.4.1.2007.1.2.16 | INTEGER (60..3024000) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (60..3024000) · read-write · mandatory In a writing operation values between 60 to 3024000 configures the new configuration test time which the device will wait before restarting the previous configuration if confirmation is not carried out. The minimum is one minute and the maximum is 5 weeks. In a reading operation, values between 60 to 3024000 shows the test time which the device will wait before restarting the previous configuration if confirmation is not carried out. | |||||||||||||||||||||
| StelAdminStatusSaveRunningConfig | 1.3.6.1.4.1.2007.1.2.17 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory In a writing operation 1 saves to flash the current running configuration. In a reading operation, 0 shows unknown output from the last set operation, 2 shows the set operation succeeded and 3 shows the last set operation failed.
| |||||||||||||||||||||
| NtelMciTraps | 1.3.6.1.4.1.2007.1.3 | ||||||||||||||||||||
| !telTECircuitTrapUp | 1.3.6.1.4.1.2007.1.3.0.1 | ||||||||||||||||||||
notification The TE-Circuit is UP. | |||||||||||||||||||||
| !telTECircuitTrapBackup | 1.3.6.1.4.1.2007.1.3.0.2 | ||||||||||||||||||||
notification The TE-Circuit is BACKUP. | |||||||||||||||||||||
| !telTECircuitTrapDown | 1.3.6.1.4.1.2007.1.3.0.3 | ||||||||||||||||||||
notification The TE-Circuit is DOWN. | |||||||||||||||||||||
| StelTrapVarIPAddr | 1.3.6.1.4.1.2007.1.3.1 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory IP address of the circuit. | |||||||||||||||||||||
| StelTrapVarVelCir | 1.3.6.1.4.1.2007.1.3.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Speed of the circuit. | |||||||||||||||||||||
| StelTrapVarVelBckp | 1.3.6.1.4.1.2007.1.3.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Speed of the backup line. | |||||||||||||||||||||
| StelTrapVarPrioBackp | 1.3.6.1.4.1.2007.1.3.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Backup priority. | |||||||||||||||||||||
| StelTrapVarTipoBackp | 1.3.6.1.4.1.2007.1.3.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Backup type. | |||||||||||||||||||||
| StelTrapVarTipoEquip | 1.3.6.1.4.1.2007.1.3.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Device model. | |||||||||||||||||||||
| StelTrapVarCustomerName | 1.3.6.1.4.1.2007.1.3.7 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Customer Name. | |||||||||||||||||||||
| StelTrapVarRouterName | 1.3.6.1.4.1.2007.1.3.8 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Router name. Format: ShortCustomerName+LocationName+ESP+aXXX. | |||||||||||||||||||||
| StelTrapVarRouterPort | 1.3.6.1.4.1.2007.1.3.9 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Port or the router. | |||||||||||||||||||||
| StelTrapVarCircuitID | 1.3.6.1.4.1.2007.1.3.10 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Circuit identifier. | |||||||||||||||||||||
| StelTrapVarSequenceNum | 1.3.6.1.4.1.2007.1.3.11 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Number of the sequence. | |||||||||||||||||||||
| NtelEventTraps | 1.3.6.1.4.1.2007.1.4 | ||||||||||||||||||||
| Ntelproto | 1.3.6.1.4.1.2007.3 | ||||||||||||||||||||
| Ntelproip | 1.3.6.1.4.1.2007.3.2 | ||||||||||||||||||||
| Nteldefgw | 1.3.6.1.4.1.2007.3.2.1 | ||||||||||||||||||||
| StelProtoIpDefGwAddress | 1.3.6.1.4.1.2007.3.2.1.1 | IpAddress | RO | optional | |||||||||||||||||
scalar · IpAddress · read-only · optional IP address of the default router of the system. | |||||||||||||||||||||
| StelProtoIpDefGwCost | 1.3.6.1.4.1.2007.3.2.1.2 | INTEGER | RO | optional | |||||||||||||||||
scalar · INTEGER · read-only · optional Cost of the default router of the system. | |||||||||||||||||||||
| StelProtoIpDefGwAge | 1.3.6.1.4.1.2007.3.2.1.3 | INTEGER | RO | optional | |||||||||||||||||
scalar · INTEGER · read-only · optional Age of the default router of the system. | |||||||||||||||||||||
| Ntelprofr | 1.3.6.1.4.1.2007.3.3 | ||||||||||||||||||||
| TtelfrLmiTable | 1.3.6.1.4.1.2007.3.3.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The table telfrLmiTable contains LMI information about each frame-relay interface of the system. | |||||||||||||||||||||
| RtelfrLmiEntry | 1.3.6.1.4.1.2007.3.3.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each entry contains LMI information of the interface.
| |||||||||||||||||||||
| CtelfrLmiifIndex | 1.3.6.1.4.1.2007.3.3.1.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Frame-relay interface (ifIndex). | |||||||||||||||||||||
| CtelfrLmiBroadcas | 1.3.6.1.4.1.2007.3.3.1.1.2 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory It points out if there is a broadcast service in the interface.
| |||||||||||||||||||||
| CtelfrLmiMonitConges | 1.3.6.1.4.1.2007.3.3.1.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory It points out if the interface performs congestion monitoring.
| |||||||||||||||||||||
| CtelfrLmiMonitCIR | 1.3.6.1.4.1.2007.3.3.1.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory It points out if the interface performs CIR monitoring.
| |||||||||||||||||||||
| CtelfrLmiOrphans | 1.3.6.1.4.1.2007.3.3.1.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory It points out if orphan circuits exit.
| |||||||||||||||||||||
| CtelfrLmiIRIncrement | 1.3.6.1.4.1.2007.3.3.1.1.6 | INTEGER (1..100) | RW | mandatory | |||||||||||||||||
column · INTEGER (1..100) · read-write · mandatory Percentage of IR increase. | |||||||||||||||||||||
| CtelfrLmiIRDecrement | 1.3.6.1.4.1.2007.3.3.1.1.7 | INTEGER (1..100) | RW | mandatory | |||||||||||||||||
column · INTEGER (1..100) · read-write · mandatory Percentage of IR decrease. | |||||||||||||||||||||
| CtelfrLmiMIRCIR | 1.3.6.1.4.1.2007.3.3.1.1.8 | INTEGER (1..100) | RW | mandatory | |||||||||||||||||
column · INTEGER (1..100) · read-write · mandatory MIR as CIR percentage. | |||||||||||||||||||||
| TtelfrCircuitTable | 1.3.6.1.4.1.2007.3.3.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The table telfrCircuitTable contains information about every configured PVC circuit in the different frame-relay interfaces of the system. This information does no appear in the frCircuitTable table. | |||||||||||||||||||||
| RtelfrCircuitEntry | 1.3.6.1.4.1.2007.3.3.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each entry contains information about every PVC of the interface. | |||||||||||||||||||||
| CtelfrCircuitifIndex | 1.3.6.1.4.1.2007.3.3.2.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Frame-relay interface (ifIndex). | |||||||||||||||||||||
| CtelfrCircuitDlci | 1.3.6.1.4.1.2007.3.3.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory DLCI number of the PVC. | |||||||||||||||||||||
| CtelfrCircuitCifrar | 1.3.6.1.4.1.2007.3.3.2.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Coding or not data.
| |||||||||||||||||||||
| CtelfrCircuitBack-Up-FR | 1.3.6.1.4.1.2007.3.3.2.1.4 | INTEGER (16..1007) | RW | mandatory | |||||||||||||||||
column · INTEGER (16..1007) · read-write · mandatory Back Up circuit through frame-relay. | |||||||||||||||||||||
| CtelfrCircuitBack-Up-RDSI | 1.3.6.1.4.1.2007.3.3.2.1.5 | INTEGER (16..1007) | RW | mandatory | |||||||||||||||||
column · INTEGER (16..1007) · read-write · mandatory Back Up circuit through RDSI. | |||||||||||||||||||||
| CtelfrCircuitBack-Up-RDSI-siempre | 1.3.6.1.4.1.2007.3.3.2.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Back Up to RDSI when this is possible through FR, regardless of the reasons.
| |||||||||||||||||||||
| CtelfrCircuitName | 1.3.6.1.4.1.2007.3.3.2.1.7 | DisplayString (SIZE (0..23)) | RW | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..23)) · read-write · mandatory Circuit name assigned. | |||||||||||||||||||||
| Ntelproisdn | 1.3.6.1.4.1.2007.3.4 | ||||||||||||||||||||
| TtelproisdncallTable | 1.3.6.1.4.1.2007.3.4.1 | NA | obsolete | ||||||||||||||||||
table · not-accessible · obsolete The table telproisdncallTable contains information about the rdsi active calls of the system. | |||||||||||||||||||||
| RtelproisdncallEntry | 1.3.6.1.4.1.2007.3.4.1.1 | NA | obsolete | ||||||||||||||||||
row · not-accessible · obsolete Each entry contains information about a rdsi line.
| |||||||||||||||||||||
| Ctelproisdncallstatus | 1.3.6.1.4.1.2007.3.4.1.1.1 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete Call state. It shows if there is really an active call in this line.
| |||||||||||||||||||||
| Ctelproisdncalltype | 1.3.6.1.4.1.2007.3.4.1.1.2 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete Call type.
| |||||||||||||||||||||
| Ctelproisdncallref | 1.3.6.1.4.1.2007.3.4.1.1.3 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete Call reference. | |||||||||||||||||||||
| Ctelproisdncallchannel | 1.3.6.1.4.1.2007.3.4.1.1.4 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete Channel B used to perform the call. | |||||||||||||||||||||
| Ctelproisdncallid | 1.3.6.1.4.1.2007.3.4.1.1.5 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete RDSI line used to perform the call. | |||||||||||||||||||||
| Ctelproisdncallcallednum | 1.3.6.1.4.1.2007.3.4.1.1.6 | DisplayString | RO | obsolete | |||||||||||||||||
column · DisplayString · read-only · obsolete Called number. | |||||||||||||||||||||
| Ctelproisdncallcallingnum | 1.3.6.1.4.1.2007.3.4.1.1.7 | DisplayString | RO | obsolete | |||||||||||||||||
column · DisplayString · read-only · obsolete Calling number. | |||||||||||||||||||||
| Ctelproisdncallchargedunits | 1.3.6.1.4.1.2007.3.4.1.1.8 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete Cost of the call. | |||||||||||||||||||||
| Ctelproisdncallinittime | 1.3.6.1.4.1.2007.3.4.1.1.9 | OCTET STRING | RO | obsolete | |||||||||||||||||
column · OCTET STRING · read-only · obsolete Byte string that shows hours, minutes and seconds since the call was initiated. | |||||||||||||||||||||
| Ctelproisdncallinitdate | 1.3.6.1.4.1.2007.3.4.1.1.10 | OCTET STRING | RO | obsolete | |||||||||||||||||
column · OCTET STRING · read-only · obsolete Byte string that shows the date the call was initiated. | |||||||||||||||||||||
| TtelproisdncallhistoryTable | 1.3.6.1.4.1.2007.3.4.2 | NA | obsolete | ||||||||||||||||||
table · not-accessible · obsolete The table telproisdncallhistoryTable contains information about the rdsi calls released of the system. | |||||||||||||||||||||
| RtelproisdncallhistoryEntry | 1.3.6.1.4.1.2007.3.4.2.1 | NA | obsolete | ||||||||||||||||||
row · not-accessible · obsolete Each entry contains information about a released rdsi call. | |||||||||||||||||||||
| Ctelproisdncallhistoryindex | 1.3.6.1.4.1.2007.3.4.2.1.1 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete The index identifies each table entry. The smallest indexes fit the calls released more time ago. | |||||||||||||||||||||
| Ctelproisdncallhistorytype | 1.3.6.1.4.1.2007.3.4.2.1.2 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete Call type.
| |||||||||||||||||||||
| Ctelproisdncallhistoryref | 1.3.6.1.4.1.2007.3.4.2.1.3 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete Call reference. | |||||||||||||||||||||
| Ctelproisdncallhistorychannel | 1.3.6.1.4.1.2007.3.4.2.1.4 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete Channel B used to perform the call. | |||||||||||||||||||||
| Ctelproisdncallhistoryid | 1.3.6.1.4.1.2007.3.4.2.1.5 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete RDSI line used to perform the call. | |||||||||||||||||||||
| Ctelproisdncallhistorycallednum | 1.3.6.1.4.1.2007.3.4.2.1.6 | DisplayString | RO | obsolete | |||||||||||||||||
column · DisplayString · read-only · obsolete Called number. | |||||||||||||||||||||
| Ctelproisdncallhistorycallingnum | 1.3.6.1.4.1.2007.3.4.2.1.7 | DisplayString | RO | obsolete | |||||||||||||||||
column · DisplayString · read-only · obsolete Calling number. | |||||||||||||||||||||
| Ctelproisdncallhistorychargedunits | 1.3.6.1.4.1.2007.3.4.2.1.8 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete Cost of the call. | |||||||||||||||||||||
| Ctelproisdncallhistorycause | 1.3.6.1.4.1.2007.3.4.2.1.9 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete Release reasons.
| |||||||||||||||||||||
| Ctelproisdncallhistorydiagnostic | 1.3.6.1.4.1.2007.3.4.2.1.10 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete Release diagnostic. | |||||||||||||||||||||
| Ctelproisdncallhistoryinittime | 1.3.6.1.4.1.2007.3.4.2.1.11 | OCTET STRING | RO | obsolete | |||||||||||||||||
column · OCTET STRING · read-only · obsolete String of bytes that shows the hours, minutes and seconds since the call was initiated. | |||||||||||||||||||||
| Ctelproisdncallhistoryendtime | 1.3.6.1.4.1.2007.3.4.2.1.12 | OCTET STRING | RO | obsolete | |||||||||||||||||
column · OCTET STRING · read-only · obsolete String of bytes that shows the hours, minutes and seconds since the call was finished. | |||||||||||||||||||||
| Ctelproisdncallhistoryinitdate | 1.3.6.1.4.1.2007.3.4.2.1.13 | OCTET STRING | RO | obsolete | |||||||||||||||||
column · OCTET STRING · read-only · obsolete Byte string that shows the date the call was initiated. | |||||||||||||||||||||
| Ctelproisdncallhistoryenddate | 1.3.6.1.4.1.2007.3.4.2.1.14 | OCTET STRING | RO | obsolete | |||||||||||||||||
column · OCTET STRING · read-only · obsolete Byte string that shows the date the call was finished. | |||||||||||||||||||||
| Ntelproducts | 1.3.6.1.4.1.2007.4 | ||||||||||||||||||||
Traps / Notifications
- telSistemaEventos
1.3.6.1.4.1.2007.0.1 - telTECircuitTrapBackup
1.3.6.1.4.1.2007.1.3.0.2 - telTECircuitTrapDown
1.3.6.1.4.1.2007.1.3.0.3 - telTECircuitTrapUp
1.3.6.1.4.1.2007.1.3.0.1