MIB Browser

PRVT-SYNC-ETHERNET-MIB

B.A.T.M. Advance Technologies
This is the MIB module to manage
synchronization over ethernet.
Organization
BATM Advanced Communication
Root OID
1.3.6.1.4.1.738.10.5.170
Last updated
Objects
62
Source
Show full MIB
snmptranslate -m PRVT-SYNC-ETHERNET-MIB -Tp
snmpwalk -v2c -c <community> -m PRVT-SYNC-ETHERNET-MIB <host> 1.3.6.1.4.1.738.10.5.170

Imports

IF-MIBifIndex
PRVT-SWITCH-MIBswitch
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDateAndTime, DisplayString, PhysAddress, RowStatus, TEXTUAL-CONVENTION, TruthValue

OID tree

NameOIDTypeAccessStatus
IprvtSyncEthernetMIB1.3.6.1.4.1.738.10.5.170
NprvtSyncEthernetMIBNotifications1.3.6.1.4.1.738.10.5.170.0
!syncEthernetInvalidESMC1.3.6.1.4.1.738.10.5.170.0.1
!syncEthernetQualityLevelChange1.3.6.1.4.1.738.10.5.170.0.2
!syncEthernetInvalidQualityLevelReceived1.3.6.1.4.1.738.10.5.170.0.3
!syncEthernetDPLLReferenceChange1.3.6.1.4.1.738.10.5.170.0.4
!syncEthernetDPLLChanged1.3.6.1.4.1.738.10.5.170.0.5
!syncEthernetDPLLLockFailed1.3.6.1.4.1.738.10.5.170.0.6
NprvtSyncEthernetMIBObjects1.3.6.1.4.1.738.10.5.170.1
SsyncEthernetHoldOffTime1.3.6.1.4.1.738.10.5.170.1.1Integer32 (300..1800)RW
SsyncEthernetWaitToRestoreTime1.3.6.1.4.1.738.10.5.170.1.2Integer32 (0..12)RW
SsyncEthernetG781OptionMode1.3.6.1.4.1.738.10.5.170.1.3INTEGERRW
TsyncEthernetClockSourceTable1.3.6.1.4.1.738.10.5.170.1.10NA
RsyncEthernetClockSourceEntry1.3.6.1.4.1.738.10.5.170.1.10.1NA
CsyncEthernetClockSourceRowStatus1.3.6.1.4.1.738.10.5.170.1.10.1.2RowStatusRC
CsyncEthernetClockSourceAdminStatus1.3.6.1.4.1.738.10.5.170.1.10.1.3INTEGERRC
CsyncEthernetClockSourceEsmc1.3.6.1.4.1.738.10.5.170.1.10.1.4TruthValueRC
CsyncEthernetClockSourceFrequency1.3.6.1.4.1.738.10.5.170.1.10.1.5Unsigned32 (0..2431)RC
CsyncEthernetClockSourceQuality1.3.6.1.4.1.738.10.5.170.1.10.1.6PrvtSyncEthernetQualityLevelTypeRC
CsyncEthernetClockSourceQualityChangeNotify1.3.6.1.4.1.738.10.5.170.1.10.1.7TruthValueRC
CsyncEthernetClockSourceRecvQualityLevel1.3.6.1.4.1.738.10.5.170.1.10.1.8PrvtSyncEthernetQualityLevelTypeRO
CsyncEthernetClockSourceLastRecvEsmcPduTime1.3.6.1.4.1.738.10.5.170.1.10.1.9DateAndTimeRO
CsyncEthernetClockSourceLastRecvEsmcErrorPduTime1.3.6.1.4.1.738.10.5.170.1.10.1.10DateAndTimeRO
CsyncEthernetClockSourceLastRecvEsmcPduType1.3.6.1.4.1.738.10.5.170.1.10.1.11Unsigned32 (0..255)RO
CsyncEthernetClockSourceLastRecvLastError1.3.6.1.4.1.738.10.5.170.1.10.1.12Unsigned32 (0..255)RO
CsyncEthernetClockSourceNumRecvEsmcPdu1.3.6.1.4.1.738.10.5.170.1.10.1.13Unsigned32RO
CsyncEthernetClockSourceNumDiscEsmcPdu1.3.6.1.4.1.738.10.5.170.1.10.1.14Unsigned32RO
CsyncEthernetClockSourceNumSignalFail1.3.6.1.4.1.738.10.5.170.1.10.1.15Unsigned32RO
CsyncEthernetClockSourceQualityInvalidNotify1.3.6.1.4.1.738.10.5.170.1.10.1.16TruthValueRC
CsyncEthernetClockSourceEsmcInvalidNotify1.3.6.1.4.1.738.10.5.170.1.10.1.17TruthValueRC
TsyncEthernetClockOutputTable1.3.6.1.4.1.738.10.5.170.1.12NA
RsyncEthernetClockOutputEntry1.3.6.1.4.1.738.10.5.170.1.12.1NA
CsyncEthernetClockOutputRowStatus1.3.6.1.4.1.738.10.5.170.1.12.1.2RowStatusRC
CsyncEthernetClockOutputEsmc1.3.6.1.4.1.738.10.5.170.1.12.1.3TruthValueRC
CsyncEthernetClockOutputFrequency1.3.6.1.4.1.738.10.5.170.1.12.1.4Unsigned32 (0..2431)RC
CsyncEthernetClockOutputDpll1.3.6.1.4.1.738.10.5.170.1.12.1.5Integer32 (0..1)RC
CsyncEthernetClockOutputQualityLevel1.3.6.1.4.1.738.10.5.170.1.12.1.6PrvtSyncEthernetQualityLevelTypeRO
CsyncEthernetClockOutputLastQualityLevelChange1.3.6.1.4.1.738.10.5.170.1.12.1.7DateAndTimeRO
CsyncEthernetClockOutputMsgEvent1.3.6.1.4.1.738.10.5.170.1.12.1.8TruthValueRO
CsyncEthernetClockOutputNumTransmittedEsmcPdu1.3.6.1.4.1.738.10.5.170.1.12.1.9Unsigned32RO
CsyncEthernetClockOutputNumTransmittedEventEsmcPdu1.3.6.1.4.1.738.10.5.170.1.12.1.10Unsigned32RO
TsyncEthernetDpllTable1.3.6.1.4.1.738.10.5.170.1.14NA
RsyncEthernetDpllEntry1.3.6.1.4.1.738.10.5.170.1.14.1NA
CsyncEthernetDpllModuleId1.3.6.1.4.1.738.10.5.170.1.14.1.1Integer32 (0..1)NA
CsyncEthernetDpllRowStatus1.3.6.1.4.1.738.10.5.170.1.14.1.2RowStatusRC
CsyncEthernetDpllAdminStatus1.3.6.1.4.1.738.10.5.170.1.14.1.3INTEGERRC
CsyncEthernetDpllReferenceSelection1.3.6.1.4.1.738.10.5.170.1.14.1.4INTEGERRC
CsyncEthernetDpllEnableQualityLevel1.3.6.1.4.1.738.10.5.170.1.14.1.5TruthValueRC
CsyncEthernetDpllStatusChangeNotify1.3.6.1.4.1.738.10.5.170.1.14.1.6TruthValueRC
CsyncEthernetDpllReferenceChangeNotify1.3.6.1.4.1.738.10.5.170.1.14.1.7TruthValueRC
CsyncEthernetDpllStatus1.3.6.1.4.1.738.10.5.170.1.14.1.8INTEGERRO
CsyncEthernetDpllStatusLastChange1.3.6.1.4.1.738.10.5.170.1.14.1.9DateAndTimeRO
CsyncEthernetDpllSystemQualityLevel1.3.6.1.4.1.738.10.5.170.1.14.1.10PrvtSyncEthernetQualityLevelTypeRO
CsyncEthernetDpllSystemQualityLevelLastChange1.3.6.1.4.1.738.10.5.170.1.14.1.11DateAndTimeRO
CsyncEthernetDpllSelectedReferenceClock1.3.6.1.4.1.738.10.5.170.1.14.1.12OCTET STRINGRO
CsyncEthernetDpllSelectedReferenceClockChange1.3.6.1.4.1.738.10.5.170.1.14.1.13DateAndTimeRO
TsyncEthernetDpllClkRefTable1.3.6.1.4.1.738.10.5.170.1.16NA
RsyncEthernetDpllClkRefEntry1.3.6.1.4.1.738.10.5.170.1.16.1NA
CsyncEthernetDpllClkRefRowStatus1.3.6.1.4.1.738.10.5.170.1.16.1.2RowStatusRC
CsyncEthernetDpllClkRefPriority1.3.6.1.4.1.738.10.5.170.1.16.1.3Unsigned32 (0..256)RC
CsyncEthernetDpllClkRefLockOut1.3.6.1.4.1.738.10.5.170.1.16.1.4TruthValueRC
CsyncEthernetDpllClkRefFailStatus1.3.6.1.4.1.738.10.5.170.1.16.1.5Integer32RO

Textual conventions

PrvtSyncEthernetQualityLevelType INTEGER

dnu(15) dus(31) failed(65) invalid(64) prc(2) prov(30) prs(17) sec(11) smc(28) ssuA(4) ssuB(8) st2(23) st3(26) st3e(29) stu(16) tnc(20)

Clock Quality Levels.

Traps / Notifications