PRVT-DRY-CONTACTS-MIB
B.A.T.M. Advance TechnologiesInitial version. This MIB provides external-alarm management and notifications
snmptranslate -m PRVT-DRY-CONTACTS-MIB -Tpsnmpwalk -v2c -c <community> -m PRVT-DRY-CONTACTS-MIB <host> 1.3.6.1.4.1.738.1.5.112Imports
| PRVT-SWITCH-MIB | switch |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| IprvtDryContactsMIB | 1.3.6.1.4.1.738.1.5.112 | |||
identity Initial version. This MIB provides external-alarm management and notifications | ||||
| NdryContactsNotifications | 1.3.6.1.4.1.738.1.5.112.0 | |||
| !stateChanged | 1.3.6.1.4.1.738.1.5.112.0.1 | |||
notification · current Send notification when operational status of the input changes | ||||
| NdryContactsObjects | 1.3.6.1.4.1.738.1.5.112.1 | |||
| TcfgTable | 1.3.6.1.4.1.738.1.5.112.1.1 | NA | ||
table · not-accessible · current A table containing inputs configuration and statuses | ||||
| RcfgEntry | 1.3.6.1.4.1.738.1.5.112.1.1.1 | NA | ||
| CprvtAlarmID | 1.3.6.1.4.1.738.1.5.112.1.1.1.1 | Integer32 (1..6) | AN | |
column · Integer32 (1..6) · accessible-for-notify · current External and internal alarm index uniquely identifies this row. T-Metro 200 ES platform has four dry-contacts sensor inputs. T5C-XG platform has four dry-contact sensor inputs and two dry-contact sensor outputs. An integer with supported range of values 1-6 for T5C-XG and 1-4 for T-Metro 200 ES. Index. Not-accessible | ||||
| CprvtSensorType | 1.3.6.1.4.1.738.1.5.112.1.1.1.2 | INTEGER | RO | |
column · INTEGER · read-only · current Sensor type. An enumeration with two values: input(1), output(2). T-Metro 200 ES platform has four dry-contacts sensor inputs. T5C-XG platform has four dry-contact sensor inputs and two dry-contact sensor outputs. Read-only.
| ||||
| CprvtName | 1.3.6.1.4.1.738.1.5.112.1.1.1.3 | OCTET STRING | RW | |
column · OCTET STRING · read-write · current Name of alarm. An OCTET-STRING with max. 16 OCTETS. Default value null string. Read-write | ||||
| CprvtDescription | 1.3.6.1.4.1.738.1.5.112.1.1.1.4 | OCTET STRING | RW | |
column · OCTET STRING · read-write · current Alarm description. An OCTET-STRING with max. 64 OCTETS. Default value null string. Read-write | ||||
| CprvtEnableStatus | 1.3.6.1.4.1.738.1.5.112.1.1.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current Senging alarms status. An enumeration with two values: enabled(1), disabled(2). Default value is disabled(2). Read-write
| ||||
| CprvtAlarmStatus | 1.3.6.1.4.1.738.1.5.112.1.1.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current Alarm status. An enumeration with two values: no-alarm(1), alarm(2). Default value is no-alarm(1). Read-only.
| ||||
| CprvtAlarmSeverity | 1.3.6.1.4.1.738.1.5.112.1.1.1.7 | INTEGER | RW | |
column · INTEGER · read-write · current Configured alarm severity. An enumeration with 4 values: info(1), minor(2), major(3) and critical(4). Default value is info(1). Read-write
| ||||
| CprvtPolarity | 1.3.6.1.4.1.738.1.5.112.1.1.1.8 | INTEGER | RW | |
column · INTEGER · read-write · current Configured polarity. An enumeration with 2 values: normally-opened(1), normally-closed(2). This object is only for T-Metro 200 ES platform. Default value is normally-opened(1). Read-write
| ||||
| CprvtLastChange | 1.3.6.1.4.1.738.1.5.112.1.1.1.9 | TimeTicks | RO | |
column · TimeTicks · read-only · current The value of sysUpTime at the time of the last operational status change. TimeTicks. Read-only | ||||
Traps / Notifications
- stateChanged
1.3.6.1.4.1.738.1.5.112.0.1