SOCOMECUPS-MIB
Socomec Sicon Upssnmptranslate -m SOCOMECUPS-MIB -Tpsnmpwalk -v2c -c <community> -m SOCOMECUPS-MIB <host> 1.3.6.1.4.1.4555Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | AutonomousType, DisplayString, PhysAddress, TEXTUAL-CONVENTION, TestAndIncr, TimeInterval, TimeStamp |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Nsocomec | 1.3.6.1.4.1.4555 | ||||||||||||||||
| Nsoftware | 1.3.6.1.4.1.4555.1 | ||||||||||||||||
| Nnetwork | 1.3.6.1.4.1.4555.1.1 | ||||||||||||||||
| Nnetvision7 | 1.3.6.1.4.1.4555.1.1.7 | ||||||||||||||||
| NupsObjects | 1.3.6.1.4.1.4555.1.1.7.1 | ||||||||||||||||
| NupsIdent | 1.3.6.1.4.1.4555.1.1.7.1.1 | ||||||||||||||||
| SupsIdentModel | 1.3.6.1.4.1.4555.1.1.7.1.1.1 | DisplayString (SIZE (0..31)) | RO | mandatory | MODULYS GP 2.0 | ||||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · mandatory The UPS Model designation. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsIdentSerialNumber | 1.3.6.1.4.1.4555.1.1.7.1.1.2 | DisplayString (SIZE (0..19)) | RO | mandatory | PD04405001 | ||||||||||||
scalar · DisplayString (SIZE (0..19)) · read-only · mandatory The UPS Serial number. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsIdentUserRef | 1.3.6.1.4.1.4555.1.1.7.1.1.3 | DisplayString (SIZE (0..11)) | RO | mandatory | |||||||||||||
scalar · DisplayString (SIZE (0..11)) · read-only · mandatory The UPS Reference. | |||||||||||||||||
| SupsIdentUserLocation | 1.3.6.1.4.1.4555.1.1.7.1.1.4 | DisplayString (SIZE (0..11)) | RO | mandatory | |||||||||||||
scalar · DisplayString (SIZE (0..11)) · read-only · mandatory The UPS Location. | |||||||||||||||||
| SupsIdentAgentSoftwareVersion | 1.3.6.1.4.1.4555.1.1.7.1.1.5 | DisplayString (SIZE (0..31)) | RO | mandatory | Net Vision 7 v7.20 | ||||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · mandatory The UPS Net Vision software version. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsSystemName | 1.3.6.1.4.1.4555.1.1.7.1.1.6 | DisplayString (SIZE (0..127)) | RO | mandatory | |||||||||||||
scalar · DisplayString (SIZE (0..127)) · read-only · mandatory The UPS Net Vision system name. | |||||||||||||||||
| SupsSystemContact | 1.3.6.1.4.1.4555.1.1.7.1.1.7 | DisplayString (SIZE (0..127)) | RO | mandatory | |||||||||||||
scalar · DisplayString (SIZE (0..127)) · read-only · mandatory The UPS Net Vision system contact. | |||||||||||||||||
| SupsSystemLocation | 1.3.6.1.4.1.4555.1.1.7.1.1.8 | DisplayString (SIZE (0..127)) | RO | mandatory | |||||||||||||
scalar · DisplayString (SIZE (0..127)) · read-only · mandatory The UPS Net Vision system location. | |||||||||||||||||
| NupsBattery | 1.3.6.1.4.1.4555.1.1.7.1.2 | ||||||||||||||||
| SupsBatteryStatus | 1.3.6.1.4.1.4555.1.1.7.1.2.1 | INTEGER | RO | mandatory | batteryCharging(3) | ||||||||||||
scalar · INTEGER · read-only · mandatory The present battery status
Example values from LibreNMS test devices
| |||||||||||||||||
| SupsSecondsOnBattery | 1.3.6.1.4.1.4555.1.1.7.1.2.2 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. -1 shall be returned if the unit is not on battery power. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsEstimatedMinutesRemaining | 1.3.6.1.4.1.4555.1.1.7.1.2.3 | INTEGER | RO | mandatory | 65535 | ||||||||||||
scalar · INTEGER · read-only · mandatory An estimate of the time to battery charge depletion under the present load conditions. Compute when UPS is on battery power Example values from LibreNMS test devices
| |||||||||||||||||
| SupsEstimatedChargeRemaining | 1.3.6.1.4.1.4555.1.1.7.1.2.4 | INTEGER | RO | mandatory | 100 | ||||||||||||
scalar · INTEGER · read-only · mandatory An estimate of the battery charge remaining expressed as a percent of full charge. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsBatteryVoltage | 1.3.6.1.4.1.4555.1.1.7.1.2.5 | INTEGER | RO | mandatory | 542 | ||||||||||||
scalar · INTEGER · read-only · mandatory The magnitude of the present battery voltage in 0.1 Volt DC. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsBatteryTemperature | 1.3.6.1.4.1.4555.1.1.7.1.2.6 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The ambient temperature at or near the UPS Battery casing in 0.1 degree Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAmbientTemperature | 1.3.6.1.4.1.4555.1.1.7.1.2.7 | INTEGER | RO | mandatory | 210 | ||||||||||||
scalar · INTEGER · read-only · mandatory The ambient temperature inside the UPS in 0.1 degree Example values from LibreNMS test devices
| |||||||||||||||||
| SupsBatteryCurrent | 1.3.6.1.4.1.4555.1.1.7.1.2.8 | INTEGER | RO | mandatory | 65535 | ||||||||||||
scalar · INTEGER · read-only · mandatory The battry current in 0.1 Amp Example values from LibreNMS test devices
| |||||||||||||||||
| SupsBatterySOC | 1.3.6.1.4.1.4555.1.1.7.1.2.9 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The battry SOC Example values from LibreNMS test devices
| |||||||||||||||||
| NupsInput | 1.3.6.1.4.1.4555.1.1.7.1.3 | ||||||||||||||||
| SupsInputNumLines | 1.3.6.1.4.1.4555.1.1.7.1.3.1 | INTEGER | RO | mandatory | 1 | ||||||||||||
scalar · INTEGER · read-only · mandatory The number of input lines utilized in this device. This variable indicates the number of rows in the input table. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsInputFrequency | 1.3.6.1.4.1.4555.1.1.7.1.3.2 | INTEGER | RO | mandatory | 500 | ||||||||||||
scalar · INTEGER · read-only · mandatory The current input frequency to the UPS system in 0.1 HZ. Example values from LibreNMS test devices
| |||||||||||||||||
| TupsInputTable | 1.3.6.1.4.1.4555.1.1.7.1.3.3 | NA | mandatory | ||||||||||||||
table · not-accessible · mandatory A list of input table entries. The number of entries is given by the value of upsInputNumLines. | |||||||||||||||||
| RupsInputEntry | 1.3.6.1.4.1.4555.1.1.7.1.3.3.1 | NA | mandatory | ||||||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular input line.
| |||||||||||||||||
| CupsInputLineIndex | 1.3.6.1.4.1.4555.1.1.7.1.3.3.1.1 | INTEGER (0..65535) | RO | mandatory | 1 | ||||||||||||
column · INTEGER (0..65535) · read-only · mandatory Example values from LibreNMS test devices
| |||||||||||||||||
| CupsInputVoltage | 1.3.6.1.4.1.4555.1.1.7.1.3.3.1.2 | INTEGER | RO | mandatory | 2400 | ||||||||||||
column · INTEGER · read-only · mandatory The input utility line voltage in 0.1 volts. Example values from LibreNMS test devices
| |||||||||||||||||
| CupsInputCurrent | 1.3.6.1.4.1.4555.1.1.7.1.3.3.1.3 | INTEGER | RO | mandatory | 655350 | ||||||||||||
column · INTEGER · read-only · mandatory The magnitude of the present input current in 0.1 A. Example values from LibreNMS test devices
| |||||||||||||||||
| CupsInputVoltageMax | 1.3.6.1.4.1.4555.1.1.7.1.3.3.1.4 | INTEGER | RO | mandatory | 2450 | ||||||||||||
column · INTEGER · read-only · mandatory The maximum utility line voltage in 0.1 VAC for last 1 minute. Example values from LibreNMS test devices
| |||||||||||||||||
| CupsInputVoltageMin | 1.3.6.1.4.1.4555.1.1.7.1.3.3.1.5 | INTEGER | RO | mandatory | 2350 | ||||||||||||
column · INTEGER · read-only · mandatory The minimum utility line voltage in 0.1 VAC for last 1 minute. Example values from LibreNMS test devices
| |||||||||||||||||
| NupsOutput | 1.3.6.1.4.1.4555.1.1.7.1.4 | ||||||||||||||||
| SupsOutputSource | 1.3.6.1.4.1.4555.1.1.7.1.4.1 | INTEGER | RO | mandatory | onInverter(3) | ||||||||||||
scalar · INTEGER · read-only · mandatory The present source of output power.
Example values from LibreNMS test devices
| |||||||||||||||||
| SupsOutputFrequency | 1.3.6.1.4.1.4555.1.1.7.1.4.2 | INTEGER | RO | mandatory | 500 | ||||||||||||
scalar · INTEGER · read-only · mandatory The current output frequency of the UPS system in 0.1 of HZ. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsOutputNumLines | 1.3.6.1.4.1.4555.1.1.7.1.4.3 | INTEGER | RO | mandatory | 1 | ||||||||||||
scalar · INTEGER · read-only · mandatory The number of output lines utilized in this device. This variable indicates the number of rows in the output table. Example values from LibreNMS test devices
| |||||||||||||||||
| TupsOutputTable | 1.3.6.1.4.1.4555.1.1.7.1.4.4 | NA | mandatory | ||||||||||||||
table · not-accessible · mandatory A list of output table entries. The number of entries is given by the value of upsOutputNumLines. | |||||||||||||||||
| RupsOutputEntry | 1.3.6.1.4.1.4555.1.1.7.1.4.4.1 | NA | mandatory | ||||||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular output line.
| |||||||||||||||||
| CupsOutputLineIndex | 1.3.6.1.4.1.4555.1.1.7.1.4.4.1.1 | INTEGER (0..65535) | RO | mandatory | 1 | ||||||||||||
column · INTEGER (0..65535) · read-only · mandatory The output line identifier. Example values from LibreNMS test devices
| |||||||||||||||||
| CupsOutputVoltage | 1.3.6.1.4.1.4555.1.1.7.1.4.4.1.2 | INTEGER | RO | mandatory | 2300 | ||||||||||||
column · INTEGER · read-only · mandatory The output voltage of the UPS system in 0.1 volts. Example values from LibreNMS test devices
| |||||||||||||||||
| CupsOutputCurrent | 1.3.6.1.4.1.4555.1.1.7.1.4.4.1.3 | INTEGER | RO | mandatory | 0 | ||||||||||||
column · INTEGER · read-only · mandatory The output current of the UPS system in 0.1 Amps. Example values from LibreNMS test devices
| |||||||||||||||||
| CupsOutputPercentLoad | 1.3.6.1.4.1.4555.1.1.7.1.4.4.1.4 | INTEGER | RO | mandatory | 0 | ||||||||||||
column · INTEGER · read-only · mandatory The percentage of the UPS power capacity presently being used on this output line Example values from LibreNMS test devices
| |||||||||||||||||
| CupsOutputKva | 1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5 | INTEGER | RO | mandatory | 0 | ||||||||||||
column · INTEGER · read-only · mandatory Output apparent power of the UPS in 0.1 kVA. Example values from LibreNMS test devices
| |||||||||||||||||
| CupsOutputKw | 1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6 | INTEGER | RO | mandatory | 65535 | ||||||||||||
column · INTEGER · read-only · mandatory Output apparent power of the UPS in 0.1 kW. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsOutputGlobalkVA | 1.3.6.1.4.1.4555.1.1.7.1.4.5 | INTEGER | RO | mandatory | 65534 | ||||||||||||
scalar · INTEGER · read-only · mandatory Output global apparent power of the UPS in 0.1 kVA. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsOutputGlobalkW | 1.3.6.1.4.1.4555.1.1.7.1.4.6 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Output global apparent power of the UPS in 0.1 kW. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsOutputLoadRate | 1.3.6.1.4.1.4555.1.1.7.1.4.7 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Output global Load Rate. Example values from LibreNMS test devices
| |||||||||||||||||
| NupsBypass | 1.3.6.1.4.1.4555.1.1.7.1.5 | ||||||||||||||||
| SupsBypassFrequency | 1.3.6.1.4.1.4555.1.1.7.1.5.1 | INTEGER | RO | mandatory | 500 | ||||||||||||
scalar · INTEGER · read-only · mandatory The present bypass frequency in 0.1 Hz. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsBypassNumLines | 1.3.6.1.4.1.4555.1.1.7.1.5.2 | INTEGER | RO | mandatory | 1 | ||||||||||||
scalar · INTEGER · read-only · mandatory The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. Example values from LibreNMS test devices
| |||||||||||||||||
| TupsBypassTable | 1.3.6.1.4.1.4555.1.1.7.1.5.3 | NA | mandatory | ||||||||||||||
table · not-accessible · mandatory A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines. | |||||||||||||||||
| RupsBypassEntry | 1.3.6.1.4.1.4555.1.1.7.1.5.3.1 | NA | mandatory | ||||||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular bypass input.
| |||||||||||||||||
| CupsBypassLineIndex | 1.3.6.1.4.1.4555.1.1.7.1.5.3.1.1 | INTEGER (0..65535) | RO | mandatory | 1 | ||||||||||||
column · INTEGER (0..65535) · read-only · mandatory The bypass line identifier. Example values from LibreNMS test devices
| |||||||||||||||||
| CupsBypassVoltage | 1.3.6.1.4.1.4555.1.1.7.1.5.3.1.2 | INTEGER | RO | mandatory | 2400 | ||||||||||||
column · INTEGER · read-only · mandatory The present bypass voltage of the UPS system in 0.1 volts. Example values from LibreNMS test devices
| |||||||||||||||||
| CupsBypassCurrent | 1.3.6.1.4.1.4555.1.1.7.1.5.3.1.3 | INTEGER | RO | mandatory | 65535 | ||||||||||||
column · INTEGER · read-only · mandatory The present bypass current of the UPS system in 0.1 Amps. Example values from LibreNMS test devices
| |||||||||||||||||
| NupsAlarm | 1.3.6.1.4.1.4555.1.1.7.1.6 | ||||||||||||||||
| SupsAlarmsPresent | 1.3.6.1.4.1.4555.1.1.7.1.6.1 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The present number of active alarm conditions. Example values from LibreNMS test devices
| |||||||||||||||||
| TupsAlarmTable | 1.3.6.1.4.1.4555.1.1.7.1.6.2 | NA | mandatory | ||||||||||||||
table · not-accessible · mandatory A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an OBJECT IDENTIFIER, upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent. | |||||||||||||||||
| RupsAlarmEntry | 1.3.6.1.4.1.4555.1.1.7.1.6.2.1 | NA | mandatory | ||||||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular alarm.
| |||||||||||||||||
| CupsAlarmId | 1.3.6.1.4.1.4555.1.1.7.1.6.2.1.1 | PositiveInteger | RO | mandatory | |||||||||||||
column · PositiveInteger · read-only · mandatory A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||||||
| CupsAlarmDescr | 1.3.6.1.4.1.4555.1.1.7.1.6.2.1.2 | AutonomousType | RO | mandatory | |||||||||||||
column · AutonomousType · read-only · mandatory A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||||||
| CupsAlarmTime | 1.3.6.1.4.1.4555.1.1.7.1.6.2.1.3 | TimeStamp | RO | mandatory | |||||||||||||
column · TimeStamp · read-only · mandatory The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0. | |||||||||||||||||
| CupsAlarmExtDes | 1.3.6.1.4.1.4555.1.1.7.1.6.2.1.4 | DisplayString | RO | mandatory | |||||||||||||
column · DisplayString · read-only · mandatory Extra description. | |||||||||||||||||
| NupsWellKnownAlarms | 1.3.6.1.4.1.4555.1.1.7.1.6.3 | ||||||||||||||||
| SupsAlarmImminentStop | 1.3.6.1.4.1.4555.1.1.7.1.6.3.1 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory UPS in imminent stop. Load will switch off. (A000) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmOverload | 1.3.6.1.4.1.4555.1.1.7.1.6.3.2 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The output load exceeds the UPS output capacity. (A001) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmTemperature | 1.3.6.1.4.1.4555.1.1.7.1.6.3.3 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory UPS temperature is out of tolerance. (A002) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmTransferLock | 1.3.6.1.4.1.4555.1.1.7.1.6.3.4 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Automatic and manual transfer are locked. (A003) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmAutoTransferImpossible | 1.3.6.1.4.1.4555.1.1.7.1.6.3.5 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Automatic transfer is disabled. Inverter and bypass sources are not synchronized (A004) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmInsufficientResources | 1.3.6.1.4.1.4555.1.1.7.1.6.3.6 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Insufficient resources alarm. The load cannot by supplied by alternate source (A005) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmRedundancyLost | 1.3.6.1.4.1.4555.1.1.7.1.6.3.7 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Redundancy lost alarm. (A006) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmOutputShortCircuit | 1.3.6.1.4.1.4555.1.1.7.1.6.3.8 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory An output short-circuit has been detected by UPS. (A007) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmMaintenance | 1.3.6.1.4.1.4555.1.1.7.1.6.3.9 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The UPS requests a maintenance service check. (A012) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmRemoteService | 1.3.6.1.4.1.4555.1.1.7.1.6.3.10 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The UPS requests a remote service action. (A013) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmGeneralFault | 1.3.6.1.4.1.4555.1.1.7.1.6.3.11 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory A general fault in the UPS has been detected. One of UPS alarm is present. (A015) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmBatteryCircuitOpen | 1.3.6.1.4.1.4555.1.1.7.1.6.3.12 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Battery circuit open. Battery breaker or fuse open. (A016) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmBatteryDischarged | 1.3.6.1.4.1.4555.1.1.7.1.6.3.13 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The UPS will be unable to sustain the present load when and if the utility power is lost. The Battery is discharched. (A017) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmLowBattery | 1.3.6.1.4.1.4555.1.1.7.1.6.3.14 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The remaining battery run-time is less than or equal to battery low threshold. (A018) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmOnBattery | 1.3.6.1.4.1.4555.1.1.7.1.6.3.15 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The UPS is drawing power from the batteries. (A019) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmBatteryTemperature | 1.3.6.1.4.1.4555.1.1.7.1.6.3.16 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Battery Temperature Alarm. (A020) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmBatteryRoom | 1.3.6.1.4.1.4555.1.1.7.1.6.3.17 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory An external alarm has been detected in the Battery room. This alarm depends on external sensor: gaz, temperature, humidity or dry-contact. (A021) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmBatteryTest | 1.3.6.1.4.1.4555.1.1.7.1.6.3.18 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The battery has been detected as weak during the test. (A022) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmBatteryFault | 1.3.6.1.4.1.4555.1.1.7.1.6.3.19 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory One or more batteries have been determined to require replacement. (A027) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmRectifierFault | 1.3.6.1.4.1.4555.1.1.7.1.6.3.20 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Rectifier Critical alarm. (A032) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmRectifierAlarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.21 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Rectifier Preventive alarm. (A033) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmRecInputBad | 1.3.6.1.4.1.4555.1.1.7.1.6.3.22 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory rectifier Input power supply is out of tolerance or absent. (A035) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmGenSetGeneral | 1.3.6.1.4.1.4555.1.1.7.1.6.3.23 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Gen-set general alarm. coming from external dry-contact. (A036) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmBatteryChargerFault | 1.3.6.1.4.1.4555.1.1.7.1.6.3.24 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Battery charger Critical Alarm. (A037) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmBatteryChargerAlarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.25 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Battery charger Preventive Alarm. (A038) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmInverterFault | 1.3.6.1.4.1.4555.1.1.7.1.6.3.26 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Inverter Critical alarm. (A040) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmInverterAlarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.27 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Inverter preventive alarm. (A041) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmBypassFault | 1.3.6.1.4.1.4555.1.1.7.1.6.3.28 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Inverter Critical alarm. (A048) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmBypassAlarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.29 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Inverter preventive alarm. (A049) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmBypInputBad | 1.3.6.1.4.1.4555.1.1.7.1.6.3.30 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Bypass Input power supply is out of tolerance or absent. (A050) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmPhaseRotationFault | 1.3.6.1.4.1.4555.1.1.7.1.6.3.31 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Phase rotation fault. (A051) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmFansFailure | 1.3.6.1.4.1.4555.1.1.7.1.6.3.32 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Fans failure. (A054) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmMaintenanceBypass | 1.3.6.1.4.1.4555.1.1.7.1.6.3.33 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Maintenance bypass alarm. Output breaker and manual bypass breaker closed together. (A056) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmUPSPowerOffActive | 1.3.6.1.4.1.4555.1.1.7.1.6.3.34 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory UPS power off has been activated by external device. (A059) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmWrongConfiguration | 1.3.6.1.4.1.4555.1.1.7.1.6.3.35 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Configuration data map corrupted, or wrong configuration. (A060) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmInternalFailure | 1.3.6.1.4.1.4555.1.1.7.1.6.3.36 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Internal failure, or internal communication failure. (A061) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmOptionalBoards | 1.3.6.1.4.1.4555.1.1.7.1.6.3.37 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Optional boards alarm. Board not present or wrong configuration (A062) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmExternalAlarm1 | 1.3.6.1.4.1.4555.1.1.7.1.6.3.38 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory External Alarm 1. Coming from ADC Card: Input set as alarm (A064) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmExternalAlarm2 | 1.3.6.1.4.1.4555.1.1.7.1.6.3.39 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory External Alarm 2. Coming from ADC Card: Input set as alarm (A065) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmExternalAlarm3 | 1.3.6.1.4.1.4555.1.1.7.1.6.3.40 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory External Alarm 3. Coming from ADC Card: Input set as alarm (A066) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmExternalAlarm4 | 1.3.6.1.4.1.4555.1.1.7.1.6.3.41 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory External Alarm 4. Coming from ADC Card: Input set as alarm (A067) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmModule1Alarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.42 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Unit or Module 1 in parallel general alarm. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmModule2Alarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.43 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Unit or Module 2 in parallel general alarm. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmModule3Alarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.44 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Unit or Module 3 in parallel general alarm. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmModule4Alarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.45 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Unit or Module 4 in parallel general alarm. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmModule5Alarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.46 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Unit or Module 5 in parallel general alarm. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmModule6Alarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.47 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Unit or Module 6 in parallel general alarm. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmModule7Alarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.48 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Unit or Module 7 in parallel general alarm. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmModule8Alarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.49 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Unit or Module 8 in parallel general alarm. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmModule9Alarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.50 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Unit or Module 9 in parallel general alarm. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmModule10Alarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.51 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Unit or Module 10 in parallel general alarm. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmModule11Alarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.52 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Unit or Module 11 in parallel general alarm. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmModule12Alarm | 1.3.6.1.4.1.4555.1.1.7.1.6.3.53 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Unit or Module 12 in parallel general alarm. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmAutoTestRunning | 1.3.6.1.4.1.4555.1.1.7.1.6.3.54 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The UPS has launched the auto-test. (S030) Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmOnBypass | 1.3.6.1.4.1.4555.1.1.7.1.6.3.55 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory Load supplied by automatic bypass. Load not protected. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmUpsOutputOff | 1.3.6.1.4.1.4555.1.1.7.1.6.3.56 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The output of the UPS is in the off state. Load OFF or UPS on standby mode. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmUpsSystemOff | 1.3.6.1.4.1.4555.1.1.7.1.6.3.57 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The UPS system is in the off state. Rectifier and Inverter are off. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmCommunicationLost | 1.3.6.1.4.1.4555.1.1.7.1.6.3.58 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The communication with UPS has been lost. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmShutdownPending | 1.3.6.1.4.1.4555.1.1.7.1.6.3.59 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The condition to shutdown servers has been detected. The shutdown delay in underway. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmShutdownRequestt | 1.3.6.1.4.1.4555.1.1.7.1.6.3.60 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The shutdown command has been sent to servers agent. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmShutdownImminent | 1.3.6.1.4.1.4555.1.1.7.1.6.3.61 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The UPS will turn OFF, according the standby schedule settings. Example values from LibreNMS test devices
| |||||||||||||||||
| SupsAlarmAwaitingPower | 1.3.6.1.4.1.4555.1.1.7.1.6.3.62 | INTEGER | RO | mandatory | 0 | ||||||||||||
scalar · INTEGER · read-only · mandatory The UPS output is in standby, and the UPS is awaiting the return of input power. Example values from LibreNMS test devices
| |||||||||||||||||
| NupsControl | 1.3.6.1.4.1.4555.1.1.7.1.7 | ||||||||||||||||
| SupsControlStatusControl | 1.3.6.1.4.1.4555.1.1.7.1.7.1 | INTEGER | RW | mandatory | |||||||||||||
scalar · INTEGER · read-write · mandatory This object Control UPS status
| |||||||||||||||||
| SupsShutdownDelay | 1.3.6.1.4.1.4555.1.1.7.1.7.2 | INTEGER | RW | mandatory | |||||||||||||
scalar · INTEGER · read-write · mandatory This object set the delay time (in seconds) to turn UPS off after Net Vision broadcast shutdown request to connected clients | |||||||||||||||||
| SupsTurnOffAfterShutdown | 1.3.6.1.4.1.4555.1.1.7.1.7.3 | INTEGER | RW | mandatory | |||||||||||||
scalar · INTEGER · read-write · mandatory This object enable/disable UPS turn off function after shutdown process complete
| |||||||||||||||||
| TupsControlShutdownParamTable | 1.3.6.1.4.1.4555.1.1.7.1.7.4 | NA | mandatory | ||||||||||||||
table · not-accessible · mandatory Table which describes the parameters for shutdown process when shutdown event occurs | |||||||||||||||||
| RshutdownParamEntry | 1.3.6.1.4.1.4555.1.1.7.1.7.4.1 | NA | mandatory | ||||||||||||||
row · not-accessible · mandatory
| |||||||||||||||||
| CupsControlEventIndex | 1.3.6.1.4.1.4555.1.1.7.1.7.4.1.1 | INTEGER (0..65535) | RO | mandatory | |||||||||||||
column · INTEGER (0..65535) · read-only · mandatory The shutdown event identification | |||||||||||||||||
| CupsControlEventStatus | 1.3.6.1.4.1.4555.1.1.7.1.7.4.1.2 | INTEGER | RW | mandatory | |||||||||||||
column · INTEGER · read-write · mandatory Status of the corresponding shutdown Event. When set to disable(), shutdown process will not start when corresponding event occurred.
| |||||||||||||||||
| CupsControlDelay | 1.3.6.1.4.1.4555.1.1.7.1.7.4.1.3 | INTEGER (0..10080) | RW | mandatory | |||||||||||||
column · INTEGER (0..10080) · read-write · mandatory The Delay after the occurrence of the corresponding shutdown event that Net Vision should issue shutdown request to connected clients. For WeeklyScheduledShutdown and SpecialScheduledShutdown, this is the time before the configured Shutdown time when Net Vision will start sending the warning message to the connected clients. The value is in units of minutes. | |||||||||||||||||
| CupsControlFirstWarning | 1.3.6.1.4.1.4555.1.1.7.1.7.4.1.4 | INTEGER (0..3600) | RW | mandatory | |||||||||||||
column · INTEGER (0..3600) · read-write · mandatory The delay after the occurrence of the corresponding shutdown event that the Net Vision will start sending the warning message to the connected clients. The value is in units of seconds | |||||||||||||||||
| CupsControlWarningInterval | 1.3.6.1.4.1.4555.1.1.7.1.7.4.1.5 | INTEGER (0..3600) | RW | mandatory | |||||||||||||
column · INTEGER (0..3600) · read-write · mandatory The frequency of sending warning messages to the connected clients when the corresponding shutdown event occurs. The value is in units of seconds. | |||||||||||||||||
| TupsControlWeeklyScheduleTable | 1.3.6.1.4.1.4555.1.1.7.1.7.5 | NA | mandatory | ||||||||||||||
table · not-accessible · mandatory The table to schedule shutting down the ups by weekly. | |||||||||||||||||
| RupsControlWeeklyScheduleEntry | 1.3.6.1.4.1.4555.1.1.7.1.7.5.1 | NA | mandatory | ||||||||||||||
| CupsControlWeeklyIndex | 1.3.6.1.4.1.4555.1.1.7.1.7.5.1.1 | INTEGER (1..7) | RO | mandatory | |||||||||||||
column · INTEGER (1..7) · read-only · mandatory The index of scheduled events. | |||||||||||||||||
| CupsControlWeeklyShutdownDay | 1.3.6.1.4.1.4555.1.1.7.1.7.5.1.2 | INTEGER | RW | mandatory | |||||||||||||
column · INTEGER · read-write · mandatory The weekday on which the UPS should shut down.
| |||||||||||||||||
| CupsControlWeeklyShutdownTime | 1.3.6.1.4.1.4555.1.1.7.1.7.5.1.3 | DisplayString (SIZE (5)) | RW | mandatory | |||||||||||||
column · DisplayString (SIZE (5)) · read-write · mandatory The time that the process of shutting down the UPS will be initiated in hh:mm format. | |||||||||||||||||
| CupsControlWeeklyRestartDay | 1.3.6.1.4.1.4555.1.1.7.1.7.5.1.4 | INTEGER | RW | mandatory | |||||||||||||
column · INTEGER · read-write · mandatory The weekday on which the UPS should restart
| |||||||||||||||||
| CupsControlWeeklyRestartTime | 1.3.6.1.4.1.4555.1.1.7.1.7.5.1.5 | DisplayString (SIZE (5)) | RW | mandatory | |||||||||||||
column · DisplayString (SIZE (5)) · read-write · mandatory The time the UPS will restart in hh:mm format. | |||||||||||||||||
| TupsControlSpecialScheduleTable | 1.3.6.1.4.1.4555.1.1.7.1.7.6 | NA | mandatory | ||||||||||||||
table · not-accessible · mandatory The table to schedule shutting down the ups. | |||||||||||||||||
| RupsControlSpecialScheduleEntry | 1.3.6.1.4.1.4555.1.1.7.1.7.6.1 | NA | mandatory | ||||||||||||||
| CupsControlSpecialIndex | 1.3.6.1.4.1.4555.1.1.7.1.7.6.1.1 | INTEGER (1..8) | RO | mandatory | |||||||||||||
column · INTEGER (1..8) · read-only · mandatory The index of scheduled events. | |||||||||||||||||
| CupsControlSpecialShutdownDay | 1.3.6.1.4.1.4555.1.1.7.1.7.6.1.2 | DisplayString (SIZE (10)) | RW | mandatory | |||||||||||||
column · DisplayString (SIZE (10)) · read-write · mandatory The date on which the UPS should shut down in dd/mm/yyyy format. | |||||||||||||||||
| CupsControlSpecialShutdownTime | 1.3.6.1.4.1.4555.1.1.7.1.7.6.1.3 | DisplayString (SIZE (5)) | RW | mandatory | |||||||||||||
column · DisplayString (SIZE (5)) · read-write · mandatory The time that the process of shutting down the UPS will be initiated in hh:mm format | |||||||||||||||||
| CupsControlSpecialRestartDay | 1.3.6.1.4.1.4555.1.1.7.1.7.6.1.4 | DisplayString (SIZE (10)) | RW | mandatory | |||||||||||||
column · DisplayString (SIZE (10)) · read-write · mandatory The date on which the UPS should restart in dd/mm/yyyy format | |||||||||||||||||
| CupsControlSpecialRestartTime | 1.3.6.1.4.1.4555.1.1.7.1.7.6.1.5 | DisplayString (SIZE (5)) | RW | mandatory | |||||||||||||
column · DisplayString (SIZE (5)) · read-write · mandatory The time the UPS will restart in hh:mm format. | |||||||||||||||||
| TupsControlEcoModeScheduleTable | 1.3.6.1.4.1.4555.1.1.7.1.7.7 | NA | mandatory | ||||||||||||||
table · not-accessible · mandatory The table to schedule enable/disable ups eco/mode by weekly. | |||||||||||||||||
| RupsControlEcoModeScheduleEntry | 1.3.6.1.4.1.4555.1.1.7.1.7.7.1 | NA | mandatory | ||||||||||||||
| CupsControlEcoModeIndex | 1.3.6.1.4.1.4555.1.1.7.1.7.7.1.1 | INTEGER (1..7) | RO | mandatory | |||||||||||||
column · INTEGER (1..7) · read-only · mandatory The index of scheduled events. | |||||||||||||||||
| CupsControlEcoModeStartDay | 1.3.6.1.4.1.4555.1.1.7.1.7.7.1.2 | INTEGER | RW | mandatory | |||||||||||||
column · INTEGER · read-write · mandatory The weekday on which the UPS Eco/Mode should enable.
| |||||||||||||||||
| CupsControlEcoModeStartTime | 1.3.6.1.4.1.4555.1.1.7.1.7.7.1.3 | DisplayString (SIZE (5)) | RW | mandatory | |||||||||||||
column · DisplayString (SIZE (5)) · read-write · mandatory The time that the UPS Eco/Mode will be enabled, in hh:mm format. | |||||||||||||||||
| CupsControlEcoModeEndDay | 1.3.6.1.4.1.4555.1.1.7.1.7.7.1.4 | INTEGER | RW | mandatory | |||||||||||||
column · INTEGER · read-write · mandatory The weekday on which the UPS Eco/Mode should disable
| |||||||||||||||||
| CupsControlEcoModeEndTime | 1.3.6.1.4.1.4555.1.1.7.1.7.7.1.5 | DisplayString (SIZE (5)) | RW | mandatory | |||||||||||||
column · DisplayString (SIZE (5)) · read-write · mandatory The time the UPS Eco/Mode will disabled, in hh:mm format. | |||||||||||||||||
| NupsConfig | 1.3.6.1.4.1.4555.1.1.7.1.8 | ||||||||||||||||
| SupsConfigNomKva | 1.3.6.1.4.1.4555.1.1.7.1.8.1 | INTEGER | RO | mandatory | 22 | ||||||||||||
scalar · INTEGER · read-only · mandatory UPS Nominal in 0.1 kVA Example values from LibreNMS test devices
| |||||||||||||||||
| SupsConfigNbrUnit | 1.3.6.1.4.1.4555.1.1.7.1.8.2 | INTEGER | RO | mandatory | |||||||||||||
scalar · INTEGER · read-only · mandatory Number of Units installed in the system | |||||||||||||||||
| SupsConfigUnitKva | 1.3.6.1.4.1.4555.1.1.7.1.8.3 | INTEGER | RO | mandatory | |||||||||||||
scalar · INTEGER · read-only · mandatory UNIT Nominal kVA | |||||||||||||||||
| SupsConfigRemoteCtrl | 1.3.6.1.4.1.4555.1.1.7.1.8.4 | INTEGER | RO | mandatory | |||||||||||||
scalar · INTEGER · read-only · mandatory Set to 1 if remote controls are enabled by UPS | |||||||||||||||||
| TupsDevicesTable | 1.3.6.1.4.1.4555.1.1.7.1.8.5 | NA | mandatory | ||||||||||||||
table · not-accessible · mandatory The devices powered by UPS and registered to NET VISION | |||||||||||||||||
| RupsDevicesEntry | 1.3.6.1.4.1.4555.1.1.7.1.8.5.1 | NA | mandatory | ||||||||||||||
| CindexOfDevice | 1.3.6.1.4.1.4555.1.1.7.1.8.5.1.1 | NonNegativeInteger | RO | mandatory | |||||||||||||
column · NonNegativeInteger · read-only · mandatory The index of the device that is powered from UPS. | |||||||||||||||||
| CaddrOfDevice | 1.3.6.1.4.1.4555.1.1.7.1.8.5.1.2 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The ip address of the device. | |||||||||||||||||
| CnameOfDevice | 1.3.6.1.4.1.4555.1.1.7.1.8.5.1.3 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The name/description of the device powered from UPS. | |||||||||||||||||
| CtimeOfConnection | 1.3.6.1.4.1.4555.1.1.7.1.8.5.1.4 | DisplayString | RO | mandatory | |||||||||||||
column · DisplayString · read-only · mandatory The device registered to NET VISION | |||||||||||||||||
| CstatusOfConnection | 1.3.6.1.4.1.4555.1.1.7.1.8.5.1.5 | INTEGER | RO | mandatory | |||||||||||||
column · INTEGER · read-only · mandatory The device status connection | |||||||||||||||||
| CseverityOfConnection | 1.3.6.1.4.1.4555.1.1.7.1.8.5.1.6 | INTEGER | RO | mandatory | |||||||||||||
column · INTEGER · read-only · mandatory The device severity | |||||||||||||||||
| NupsAgent | 1.3.6.1.4.1.4555.1.1.7.1.9 | ||||||||||||||||
| SupsAgentIpaddress | 1.3.6.1.4.1.4555.1.1.7.1.9.1 | IpAddress | RW | mandatory | |||||||||||||
scalar · IpAddress · read-write · mandatory The ip address that NMS can identify the managed device | |||||||||||||||||
| SupsAgentGateway | 1.3.6.1.4.1.4555.1.1.7.1.9.2 | IpAddress | RW | mandatory | |||||||||||||
scalar · IpAddress · read-write · mandatory The default gateway that allow device managed through routers | |||||||||||||||||
| SupsAgentSubnetMask | 1.3.6.1.4.1.4555.1.1.7.1.9.3 | IpAddress | RW | mandatory | |||||||||||||
scalar · IpAddress · read-write · mandatory Internet address subnet mask | |||||||||||||||||
| SupsAgentDate | 1.3.6.1.4.1.4555.1.1.7.1.9.4 | DisplayString (SIZE (10)) | RW | mandatory | |||||||||||||
scalar · DisplayString (SIZE (10)) · read-write · mandatory The date in agent, format is (dd/mm/yyyy) | |||||||||||||||||
| SupsAgentTime | 1.3.6.1.4.1.4555.1.1.7.1.9.5 | DisplayString (SIZE (8)) | RW | mandatory | |||||||||||||
scalar · DisplayString (SIZE (8)) · read-write · mandatory The time in agent, format is (hh:mm:ss) | |||||||||||||||||
| SupsAgentNtpTimeServer | 1.3.6.1.4.1.4555.1.1.7.1.9.6 | DisplayString | RW | mandatory | |||||||||||||
| SupsAgentNtpTimeZone | 1.3.6.1.4.1.4555.1.1.7.1.9.7 | INTEGER | RW | mandatory | |||||||||||||
scalar · INTEGER · read-write · mandatory
| |||||||||||||||||
| SupsAgentHistoryLogFrequency | 1.3.6.1.4.1.4555.1.1.7.1.9.8 | INTEGER (5..28800) | RW | mandatory | |||||||||||||
scalar · INTEGER (5..28800) · read-write · mandatory The frequency of the updation of the history log. The value is in seconds | |||||||||||||||||
| SupsAgentExtHistoryLogFrequency | 1.3.6.1.4.1.4555.1.1.7.1.9.9 | INTEGER (3..10080) | RW | mandatory | |||||||||||||
scalar · INTEGER (3..10080) · read-write · mandatory The ups parameters are sampled at the rate governed by the mconfigHistroyLogFrequency. These sampled values are further conslidated over period of time which is determined by this object. | |||||||||||||||||
| SupsAgentPollRate | 1.3.6.1.4.1.4555.1.1.7.1.9.10 | INTEGER (1..60) | RW | mandatory | |||||||||||||
scalar · INTEGER (1..60) · read-write · mandatory The frequency that proxy agent polls the connected UPS in JBUS protocol. (unit : second) | |||||||||||||||||
| SupsAgentBaudRate | 1.3.6.1.4.1.4555.1.1.7.1.9.11 | INTEGER | RO | mandatory | |||||||||||||
scalar · INTEGER · read-only · mandatory The serial port communication speed. 2400,9600,19200,57600 allowed | |||||||||||||||||
| SupsAgentDhcpStatue | 1.3.6.1.4.1.4555.1.1.7.1.9.12 | INTEGER | RW | mandatory | |||||||||||||
scalar · INTEGER · read-write · mandatory Enable or disable DHCP/BootP capability
| |||||||||||||||||
| SupsAgentTelnetStatus | 1.3.6.1.4.1.4555.1.1.7.1.9.13 | INTEGER | RW | mandatory | |||||||||||||
scalar · INTEGER · read-write · mandatory Enable or disable telnet access
| |||||||||||||||||
| SupsAgentTftpStatus | 1.3.6.1.4.1.4555.1.1.7.1.9.14 | INTEGER | RW | mandatory | |||||||||||||
scalar · INTEGER · read-write · mandatory Enable or disable network upgrade capability
| |||||||||||||||||
| SupsAgentResetToDefault | 1.3.6.1.4.1.4555.1.1.7.1.9.15 | INTEGER | RW | mandatory | |||||||||||||
scalar · INTEGER · read-write · mandatory Reset all parameters of Net Vision to default value
| |||||||||||||||||
| SupsAgentRestart | 1.3.6.1.4.1.4555.1.1.7.1.9.16 | INTEGER | RW | mandatory | |||||||||||||
scalar · INTEGER · read-write · mandatory Restart Net Vision
| |||||||||||||||||
| SupsAgentClearAgentLog | 1.3.6.1.4.1.4555.1.1.7.1.9.17 | INTEGER | RW | mandatory | |||||||||||||
scalar · INTEGER · read-write · mandatory Clear agent log data
| |||||||||||||||||
| SupsAgentClearEventLog | 1.3.6.1.4.1.4555.1.1.7.1.9.18 | INTEGER | RW | mandatory | |||||||||||||
scalar · INTEGER · read-write · mandatory Clear event log data
| |||||||||||||||||
| SupsAgentClearExtHistoryLog | 1.3.6.1.4.1.4555.1.1.7.1.9.19 | INTEGER | RW | mandatory | |||||||||||||
scalar · INTEGER · read-write · mandatory Clear extented history log data
| |||||||||||||||||
| SupsAgentClearHistoryLog | 1.3.6.1.4.1.4555.1.1.7.1.9.20 | INTEGER | RW | mandatory | |||||||||||||
scalar · INTEGER · read-write · mandatory Clear history log data
| |||||||||||||||||
| TupsAgentTrapsReceiversTable | 1.3.6.1.4.1.4555.1.1.7.1.9.21 | NA | mandatory | ||||||||||||||
table · not-accessible · mandatory A list of managers to send traps to. The number of entries is given by the value of upsAgentNumTrapReceivers | |||||||||||||||||
| RupsAgentTrapsReceiversEntry | 1.3.6.1.4.1.4555.1.1.7.1.9.21.1 | NA | mandatory | ||||||||||||||
| CtrapsIndex | 1.3.6.1.4.1.4555.1.1.7.1.9.21.1.1 | INTEGER (1..8) | RO | mandatory | |||||||||||||
column · INTEGER (1..8) · read-only · mandatory The index to a trap receiver entry. | |||||||||||||||||
| CtrapsReceiverAddr | 1.3.6.1.4.1.4555.1.1.7.1.9.21.1.2 | DisplayString | RW | mandatory | |||||||||||||
column · DisplayString · read-write · mandatory The IP address of the manager to send a trap to. | |||||||||||||||||
| CreceiverCommunityString | 1.3.6.1.4.1.4555.1.1.7.1.9.21.1.3 | DisplayString (SIZE (0..31)) | RW | mandatory | |||||||||||||
column · DisplayString (SIZE (0..31)) · read-write · mandatory The community name to use in the trap when sent to the manager. | |||||||||||||||||
| CreceiverNmstype | 1.3.6.1.4.1.4555.1.1.7.1.9.21.1.4 | INTEGER | RW | mandatory | |||||||||||||
column · INTEGER · read-write · mandatory The trap group that NMS desired.
| |||||||||||||||||
| TupsAgentFirewallControlTable | 1.3.6.1.4.1.4555.1.1.7.1.9.22 | NA | mandatory | ||||||||||||||
table · not-accessible · mandatory A list of managers which can access Net Vision with private community string. | |||||||||||||||||
| RupsAgentFirewallControlEntry | 1.3.6.1.4.1.4555.1.1.7.1.9.22.1 | NA | mandatory | ||||||||||||||
| CfirewallIndex | 1.3.6.1.4.1.4555.1.1.7.1.9.22.1.1 | INTEGER | RO | mandatory | |||||||||||||
column · INTEGER · read-only · mandatory The index to a firewall entry. | |||||||||||||||||
| CfirewallControlAddr | 1.3.6.1.4.1.4555.1.1.7.1.9.22.1.2 | DisplayString | RW | mandatory | |||||||||||||
column · DisplayString · read-write · mandatory The IP address of the firewall | |||||||||||||||||
| CfirewallPrefixLength | 1.3.6.1.4.1.4555.1.1.7.1.9.22.1.3 | INTEGER (1..64) | RW | mandatory | |||||||||||||
column · INTEGER (1..64) · read-write · mandatory The firewall prefix length. | |||||||||||||||||
| CfirewallActionMode | 1.3.6.1.4.1.4555.1.1.7.1.9.22.1.4 | INTEGER | RW | mandatory | |||||||||||||
column · INTEGER · read-write · mandatory The firewall action mode
| |||||||||||||||||
| SupsAgentMibVersion | 1.3.6.1.4.1.4555.1.1.7.1.9.23 | INTEGER | RO | mandatory | |||||||||||||
scalar · INTEGER · read-only · mandatory The version of MIB spec. | |||||||||||||||||
| NemdStatus | 1.3.6.1.4.1.4555.1.1.7.1.10 | ||||||||||||||||
| SemdSatatusTemperature | 1.3.6.1.4.1.4555.1.1.7.1.10.1 | INTEGER | RO | mandatory | |||||||||||||
scalar · INTEGER · read-only · mandatory The measurement of EMD temperature, in 0.1 degree | |||||||||||||||||
| SemdSatatusHumidity | 1.3.6.1.4.1.4555.1.1.7.1.10.2 | INTEGER | RO | mandatory | |||||||||||||
scalar · INTEGER · read-only · mandatory The measurement of EMD humidity, in 0.1 degree | |||||||||||||||||
| SemdStatusIn1Active | 1.3.6.1.4.1.4555.1.1.7.1.10.3 | INTEGER | RO | mandatory | |||||||||||||
scalar · INTEGER · read-only · mandatory The input 1 has been detected as Active
| |||||||||||||||||
| SemdStatusIn2Active | 1.3.6.1.4.1.4555.1.1.7.1.10.4 | INTEGER | RO | mandatory | |||||||||||||
scalar · INTEGER · read-only · mandatory The input 2 has been detected as Active
| |||||||||||||||||
| NupsTraps | 1.3.6.1.4.1.4555.1.1.7.2 | ||||||||||||||||
| !upsTrapOnBattery | 1.3.6.1.4.1.4555.1.1.7.2.0.1 | ||||||||||||||||
notification WARNING:The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||||||
| !upsTrapTestCompleted | 1.3.6.1.4.1.4555.1.1.7.2.0.2 | ||||||||||||||||
notification INFORMATION:This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||||||
| !upsTrapAlarmEntryAdded | 1.3.6.1.4.1.4555.1.1.7.2.0.3 | ||||||||||||||||
notification WARNING:This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for upsAlarmOnBattery and upsAlarmTestInProgress.
| |||||||||||||||||
| !upsTrapAlarmEntryRemoved | 1.3.6.1.4.1.4555.1.1.7.2.0.4 | ||||||||||||||||
notification INFORMATION:This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for upsAlarmTestInProgress.
| |||||||||||||||||
| !upsTrapImminentStop | 1.3.6.1.4.1.4555.1.1.7.2.0.5 | ||||||||||||||||
notification CRITICAL: The UPS is near to switch off the output power. | |||||||||||||||||
| !upsTrapOverload | 1.3.6.1.4.1.4555.1.1.7.2.0.6 | ||||||||||||||||
notification WARNING: The UPS output is in overload. Output load rate more than 100% | |||||||||||||||||
| !upsTrapRedundancyLost | 1.3.6.1.4.1.4555.1.1.7.2.0.7 | ||||||||||||||||
notification WARNING: Redundancy is lost. | |||||||||||||||||
| !upsTrapBatteryCircuitOpen | 1.3.6.1.4.1.4555.1.1.7.2.0.8 | ||||||||||||||||
notification CRITICAL: The battery has been disconnected from UPS | |||||||||||||||||
| !upsTrapBatteryDischarged | 1.3.6.1.4.1.4555.1.1.7.2.0.9 | ||||||||||||||||
notification CRITICAL: The battery has been detected as discharged. | |||||||||||||||||
| !upsTrapBatteryLow | 1.3.6.1.4.1.4555.1.1.7.2.0.10 | ||||||||||||||||
notification CRITICAL: The battery is near of the end of backup time. | |||||||||||||||||
| !upsTrapBatteryAlarm | 1.3.6.1.4.1.4555.1.1.7.2.0.11 | ||||||||||||||||
notification WARNING: The battery is in alarm. | |||||||||||||||||
| !upsTrapUpsCriticalAlarm | 1.3.6.1.4.1.4555.1.1.7.2.0.12 | ||||||||||||||||
notification CRITICAL: A critical alarm has been detected on the UPS. | |||||||||||||||||
| !upsTrapLoadOFF | 1.3.6.1.4.1.4555.1.1.7.2.0.13 | ||||||||||||||||
notification CRITICAL: The load has been disconnected from the UPS. LOAD OFF. | |||||||||||||||||
| !upsTrapCommunicationLost | 1.3.6.1.4.1.4555.1.1.7.2.0.14 | ||||||||||||||||
notification CRITICAL: UPS is no more communicating with the agent. | |||||||||||||||||
| !upsTrapOnBatteryPower | 1.3.6.1.4.1.4555.1.1.7.2.0.15 | ||||||||||||||||
notification WARNING: The UPS has switched to battery backup power. | |||||||||||||||||
| !upsTrapBatteryTestfailed | 1.3.6.1.4.1.4555.1.1.7.2.0.16 | ||||||||||||||||
notification WARNING: The Battery test has detected a weak battery. | |||||||||||||||||
| !upsTrapTemperatureAlarm | 1.3.6.1.4.1.4555.1.1.7.2.0.17 | ||||||||||||||||
notification WARNING: The UPS internal temperature has reached the threshold. | |||||||||||||||||
| !upsTrapOnBypass | 1.3.6.1.4.1.4555.1.1.7.2.0.18 | ||||||||||||||||
notification WARNING: Load supplied by automatic Bypass. | |||||||||||||||||
| !upsTrapUpsPreventiveAlarm | 1.3.6.1.4.1.4555.1.1.7.2.0.19 | ||||||||||||||||
notification WARNING: A preventive alarm has been detected by the UPS. | |||||||||||||||||
| !upsTrapShutdownWarning | 1.3.6.1.4.1.4555.1.1.7.2.0.20 | ||||||||||||||||
notification WARNING: A warning message has be sent to shutdown agent. | |||||||||||||||||
| !upsTrapShutdownrequest | 1.3.6.1.4.1.4555.1.1.7.2.0.21 | ||||||||||||||||
notification WARNING: A shutdown command has been sent to agent. | |||||||||||||||||
| !upsTrapUpsNormal | 1.3.6.1.4.1.4555.1.1.7.2.0.22 | ||||||||||||||||
notification INFORMATION: The UPS status is normal. Load protected by UPS | |||||||||||||||||
| !upsTrapPowerRestored | 1.3.6.1.4.1.4555.1.1.7.2.0.23 | ||||||||||||||||
notification INFORMATION: The Input supply has been restored | |||||||||||||||||
| !upsTrapAlarmCancelled | 1.3.6.1.4.1.4555.1.1.7.2.0.24 | ||||||||||||||||
notification INFORMATION: Alarm cancelled. All alarms are disabled | |||||||||||||||||
| !upsTrapComEstablished | 1.3.6.1.4.1.4555.1.1.7.2.0.25 | ||||||||||||||||
notification INFORMATION: The communication between UPS and the agent has been restored | |||||||||||||||||
| !upsTrapShutdwonCancelled | 1.3.6.1.4.1.4555.1.1.7.2.0.26 | ||||||||||||||||
notification INFORMATION: The UPS has cancelled the shutdown procedure to agent | |||||||||||||||||
| !upsTrapAgentRestarting | 1.3.6.1.4.1.4555.1.1.7.2.0.27 | ||||||||||||||||
notification INFORMATION: NET VISION is restarting | |||||||||||||||||
| !upsTrapEmdTempLow | 1.3.6.1.4.1.4555.1.1.7.2.0.28 | ||||||||||||||||
notification CRITICAL: EMD Sensor detected low temperature. | |||||||||||||||||
| !upsTrapEmdTempNotLow | 1.3.6.1.4.1.4555.1.1.7.2.0.29 | ||||||||||||||||
notification INFORMATION: EMD Sensor Not under low temperature. | |||||||||||||||||
| !upsTrapEmdTempHigh | 1.3.6.1.4.1.4555.1.1.7.2.0.30 | ||||||||||||||||
notification CRITICAL: EMD Sensor detected high temperature. | |||||||||||||||||
| !upsTrapEmdTempNotHigh | 1.3.6.1.4.1.4555.1.1.7.2.0.31 | ||||||||||||||||
notification INFORMATION: EMD Sensor Not over high temperature. | |||||||||||||||||
| !upsTrapEmdHumidityLow | 1.3.6.1.4.1.4555.1.1.7.2.0.32 | ||||||||||||||||
notification CRITICAL: EMD Sensor detected low humidity. | |||||||||||||||||
| !upsTrapEmdHumidityNotLow | 1.3.6.1.4.1.4555.1.1.7.2.0.33 | ||||||||||||||||
notification INFORMATION: EMD Sensor Not under low humidity. | |||||||||||||||||
| !upsTrapEmdHumidityHigh | 1.3.6.1.4.1.4555.1.1.7.2.0.34 | ||||||||||||||||
notification CRITICAL: EMD Sensor detected high humidity. | |||||||||||||||||
| !upsTrapEmdHumidityNotHigh | 1.3.6.1.4.1.4555.1.1.7.2.0.35 | ||||||||||||||||
notification INFORMATION: EMD Sensor Not over high humidity. | |||||||||||||||||
| !upsTrapEmdFirstInputActive | 1.3.6.1.4.1.4555.1.1.7.2.0.36 | ||||||||||||||||
notification CRITICAL: The <customized> input is active. | |||||||||||||||||
| !upsTrapEmdFirstInputRestored | 1.3.6.1.4.1.4555.1.1.7.2.0.37 | ||||||||||||||||
notification INFORMATION: The <customized> input is restored. | |||||||||||||||||
| !upsTrapEmdSecondInputActive | 1.3.6.1.4.1.4555.1.1.7.2.0.38 | ||||||||||||||||
notification CRITICAL: The <customized> input is active. | |||||||||||||||||
| !upsTrapEmdSecondInputRestored | 1.3.6.1.4.1.4555.1.1.7.2.0.39 | ||||||||||||||||
notification INFORMATION: The <customized> input is restored. | |||||||||||||||||
| !upsTrapSessionLogin | 1.3.6.1.4.1.4555.1.1.7.2.0.40 | ||||||||||||||||
notification INFORMATION: New Admin or User session opened. | |||||||||||||||||
| !upsTrapLoginUnsuccesfulTentative | 1.3.6.1.4.1.4555.1.1.7.2.0.41 | ||||||||||||||||
notification WARNING: Admin or User account locked. | |||||||||||||||||
| !upsTrapTest | 1.3.6.1.4.1.4555.1.1.7.2.0.42 | ||||||||||||||||
notification INFORMATION: Send test trap. | |||||||||||||||||
Traps / Notifications
- upsTrapAgentRestarting
1.3.6.1.4.1.4555.1.1.7.2.0.27 - upsTrapAlarmCancelled
1.3.6.1.4.1.4555.1.1.7.2.0.24 - upsTrapAlarmEntryAdded
1.3.6.1.4.1.4555.1.1.7.2.0.3 - upsTrapAlarmEntryRemoved
1.3.6.1.4.1.4555.1.1.7.2.0.4 - upsTrapBatteryAlarm
1.3.6.1.4.1.4555.1.1.7.2.0.11 - upsTrapBatteryCircuitOpen
1.3.6.1.4.1.4555.1.1.7.2.0.8 - upsTrapBatteryDischarged
1.3.6.1.4.1.4555.1.1.7.2.0.9 - upsTrapBatteryLow
1.3.6.1.4.1.4555.1.1.7.2.0.10 - upsTrapBatteryTestfailed
1.3.6.1.4.1.4555.1.1.7.2.0.16 - upsTrapComEstablished
1.3.6.1.4.1.4555.1.1.7.2.0.25 - upsTrapCommunicationLost
1.3.6.1.4.1.4555.1.1.7.2.0.14 - upsTrapEmdFirstInputActive
1.3.6.1.4.1.4555.1.1.7.2.0.36 - upsTrapEmdFirstInputRestored
1.3.6.1.4.1.4555.1.1.7.2.0.37 - upsTrapEmdHumidityHigh
1.3.6.1.4.1.4555.1.1.7.2.0.34 - upsTrapEmdHumidityLow
1.3.6.1.4.1.4555.1.1.7.2.0.32 - upsTrapEmdHumidityNotHigh
1.3.6.1.4.1.4555.1.1.7.2.0.35 - upsTrapEmdHumidityNotLow
1.3.6.1.4.1.4555.1.1.7.2.0.33 - upsTrapEmdSecondInputActive
1.3.6.1.4.1.4555.1.1.7.2.0.38 - upsTrapEmdSecondInputRestored
1.3.6.1.4.1.4555.1.1.7.2.0.39 - upsTrapEmdTempHigh
1.3.6.1.4.1.4555.1.1.7.2.0.30 - upsTrapEmdTempLow
1.3.6.1.4.1.4555.1.1.7.2.0.28 - upsTrapEmdTempNotHigh
1.3.6.1.4.1.4555.1.1.7.2.0.31 - upsTrapEmdTempNotLow
1.3.6.1.4.1.4555.1.1.7.2.0.29 - upsTrapImminentStop
1.3.6.1.4.1.4555.1.1.7.2.0.5 - upsTrapLoadOFF
1.3.6.1.4.1.4555.1.1.7.2.0.13 - upsTrapLoginUnsuccesfulTentative
1.3.6.1.4.1.4555.1.1.7.2.0.41 - upsTrapOnBattery
1.3.6.1.4.1.4555.1.1.7.2.0.1 - upsTrapOnBatteryPower
1.3.6.1.4.1.4555.1.1.7.2.0.15 - upsTrapOnBypass
1.3.6.1.4.1.4555.1.1.7.2.0.18 - upsTrapOverload
1.3.6.1.4.1.4555.1.1.7.2.0.6 - upsTrapPowerRestored
1.3.6.1.4.1.4555.1.1.7.2.0.23 - upsTrapRedundancyLost
1.3.6.1.4.1.4555.1.1.7.2.0.7 - upsTrapSessionLogin
1.3.6.1.4.1.4555.1.1.7.2.0.40 - upsTrapShutdownWarning
1.3.6.1.4.1.4555.1.1.7.2.0.20 - upsTrapShutdownrequest
1.3.6.1.4.1.4555.1.1.7.2.0.21 - upsTrapShutdwonCancelled
1.3.6.1.4.1.4555.1.1.7.2.0.26 - upsTrapTemperatureAlarm
1.3.6.1.4.1.4555.1.1.7.2.0.17 - upsTrapTest
1.3.6.1.4.1.4555.1.1.7.2.0.42 - upsTrapTestCompleted
1.3.6.1.4.1.4555.1.1.7.2.0.2 - upsTrapUpsCriticalAlarm
1.3.6.1.4.1.4555.1.1.7.2.0.12 - upsTrapUpsNormal
1.3.6.1.4.1.4555.1.1.7.2.0.22 - upsTrapUpsPreventiveAlarm
1.3.6.1.4.1.4555.1.1.7.2.0.19