MIB Browser

MSERIES-TC

SmartOptics AS
This is the enterprise specific TC MIB for SmartOptics M-Series
Organization
SmartOptics
Root OID
1.3.6.1.4.1.30826.1.5
Last updated
Objects
1
Source
Show full MIB
snmptranslate -m MSERIES-TC -Tp
snmpwalk -v2c -c <community> -m MSERIES-TC <host> 1.3.6.1.4.1.30826.1.5

Imports

MSERIES-MIBmseries
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION

OID tree

NameOIDTypeAccessStatus
IsmartTcMIB1.3.6.1.4.1.30826.1.5

Textual conventions

AlarmNotificationType INTEGER

communicationsAlarm(2) environmental(6) equipmentAlarm(5) integrityViolation(7) operationalViolation(8) other(1) physicalViolation(9) processingErrorAlarm(4) qualityOfServiceAlarm(3) securityServiceOrMechanismViloation(10) timeDomainViolation(11) undefined(0)

Type of alarm as defined in ITU-T X.733.
AlarmPerceivedSeverity INTEGER

cleared(1) critical(3) indeterminate(2) major(4) minor(5) warning(6)

Alarm severity as defined in ITU-T X.733.
AlarmProbableCause INTEGER

adapterError(1) applicationSubsystemFailure(2) bandwidthReduced(3) callEstablishmentError(4) communicationsProtocolError(5) communicationsSubsystemFailure(6) configurationOrCustomizationError(7) congestion(8) corruptData(9) cpuCyclesLimitExceeded(10) dTEdCEInterfaceError(11) datasetOrModemError(12) degradedSignal(13) enclosureDoorOpen(14) equipmentMalfunction(15) excessiveVibration(16) fileError(17) fireDetected(18) floodDetected(19) framingError(20) heatingOrVentilationOrCoolingSystemProblem(21) humidityUnacceptable(22) inputDeviceError(23) inputOutputDeviceError(24) lANError(25) leakDetected(26) localNodeTransmissionError(27) lossOfFrame(28) lossOfSignal(29) materialSupplyExhausted(30) multiplexerProblem(31) outOfMemory(32) outputDeviceError(33) performanceDegraded(34) powerProblem(35) pressureUnacceptable(36) processorProblem(37) pumpFailure(38) queueSizeExceeded(39) receiveFailure(40) receiverFailure(41) remoteNodeTransmissionError(42) resourceAtOrNearingCapacity(43) responseTimeExcessive(44) retransmissionRateExcessive(45) softwareError(47) softwareProgramAbnormallyTerminated(48) softwareProgramError(46) storageCapacityProblem(49) temperatureUnacceptable(50) thresholdCrossed(51) timingProblem(52) toxicLeakDetected(53) transmitFailure(54) transmitterFailure(55) undefined(0) underlyingResourceUnavailable(56) versionMismatch(57)

Alarm probable cause as defined in ITU-T X.733.
PortMode INTEGER

normal(1) service(2)

Port Mode.

normal - The port is active. Alarms are not suppressed.

service - the port is in Service Mode. Alarms are
beeing suppressed. When service is ready the
Port Mode should be set back to normal.
PortStatus INTEGER

cd(7) down(2) eyeSafety(6) high(4) idle(1) low(5) ncd(8) up(3)

The operational state for a port.

idle - The port is not activated

down - The port traffic is lost.

up - There is traffic on the port.

high - The port got to high power.

low - The port got to low power.

eyeSafety - The Line Tx port is in Eye Safety Mode.
This means that either the connector on the
Line Tx port is not inserted or that you have
too strong reflection from the line fiber.

cd - Channel detected.

ncd - No channel detected.
PortType INTEGER

biDi(3) rx(1) tx(2)

Port direction.

rx - The port direction is receiving(Rx).

tx - The port direction is transmitting(Tx).

biDi - The port direction is both transmitting and receiving.
UnitType INTEGER

fan(4) nmb(1) psu1(2) psu2(3) slaveFan(9) slaveNmb(6) slavePsu1(7) slavePsu2(8) system(5)

The unit type in the M-Series.

nmb - Network Management Board. The controlling
board of the M-Series.

psu1 - The Power Supply in slot 1 of the M-Series.

psu2 - The Power Supply in slot 2 of the M-Series.

fan  - The Fan of the M-Series.

system - The chassis.

slaveNmb - Network Management Board of the Cascading system.

slavePsu1 - The Power Supply in slot 1 of the Cascading M-Series.

slavePsu2 - The Power Supply in slot 2 of the Cascading M-Series.

slaveFan - The Fan of the Cascading M-Series.

Used by