DCP-LINKVIEW-MIB
SmartOptics ASThis is the enterprise specific DCP LINKVIEW MIB for Smartoptics
snmptranslate -m DCP-LINKVIEW-MIB -Tpsnmpwalk -v2c -c <community> -m DCP-LINKVIEW-MIB <host> 1.3.6.1.4.1.30826.2.2.3Imports
| DCP-MIB | dcpGeneric |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
| SO-TC-MIB | InterfaceStatus, OpticalPower1Decimal |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IdcpLinkview | 1.3.6.1.4.1.30826.2.2.3 | ||||||||||||||||
identity This is the enterprise specific DCP LINKVIEW MIB for Smartoptics | |||||||||||||||||
| NdcpLinkviewObjects | 1.3.6.1.4.1.30826.2.2.3.1 | ||||||||||||||||
| TdcpLinkviewTable | 1.3.6.1.4.1.30826.2.2.3.1.1 | NA | |||||||||||||||
table · not-accessible · current Description. | |||||||||||||||||
| RdcpLinkviewEntry | 1.3.6.1.4.1.30826.2.2.3.1.1.1 | NA | |||||||||||||||
| CdcpLinkviewIndex | 1.3.6.1.4.1.30826.2.2.3.1.1.1.1 | Unsigned32 (1..1000000) | NA | ||||||||||||||
column · Unsigned32 (1..1000000) · not-accessible · current Interface Index in the following format: csiixy where c: chassis. s: slot number. ii: Interface number. x: 1 = line, 2 = client. y: 0 = tx+rx port, 1 = tx port, 2 = rx port. For DCP-M products Slot is always 0. Same Index is used in the IF-MIB. | |||||||||||||||||
| CdcpLinkviewLocalHostname | 1.3.6.1.4.1.30826.2.2.3.1.1.1.2 | DisplayString | RO | ols01-cnco01.tingfiber.net | |||||||||||||
column · DisplayString · read-only · current The hostname of the local system. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewLocalName | 1.3.6.1.4.1.30826.2.2.3.1.1.1.3 | DisplayString | RO | if-1/line-tx | |||||||||||||
column · DisplayString · read-only · current The local interface name. If no interface this value is empty. if-c/channelid-direction where c = chassis and direction = rx or tx. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewLocalStatus | 1.3.6.1.4.1.30826.2.2.3.1.1.1.4 | InterfaceStatus | RO | 3 | |||||||||||||
column · InterfaceStatus · read-only · current The operational state of the local port. idle - The port is not activated. down - The port traffic is lost. up - There is traffic on the port. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewLocalPower | 1.3.6.1.4.1.30826.2.2.3.1.1.1.5 | OpticalPower1Decimal | RO | 48 | |||||||||||||
column · OpticalPower1Decimal · read-only · current The optical power present at the line interface, all wavelengths combined in units of 0.1 dBm. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewFiberLoss | 1.3.6.1.4.1.30826.2.2.3.1.1.1.6 | DcpFiberLoss | RO | 141 | |||||||||||||
column · DcpFiberLoss · read-only · current The fiber loss in units of 0.1 dB. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewFiberAttenuation | 1.3.6.1.4.1.30826.2.2.3.1.1.1.7 | DcpFiberAttenuation | RO | 0 | |||||||||||||
column · DcpFiberAttenuation · read-only · current The fiber attenuation in units of 0.01 dB/km. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewFiberLength | 1.3.6.1.4.1.30826.2.2.3.1.1.1.8 | DcpFiberLength | RO | 0 | |||||||||||||
column · DcpFiberLength · read-only · current The fiber length in units of 0.1 km. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewFiberDispersion | 1.3.6.1.4.1.30826.2.2.3.1.1.1.9 | Unsigned32 (0..10000) | RO | 1 | |||||||||||||
column · Unsigned32 (0..10000) · read-only · current The calculated dispersion based on the measured fiber length in units of 1 ps/nm. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewFiberType | 1.3.6.1.4.1.30826.2.2.3.1.1.1.10 | DisplayString | RO | G.652 | |||||||||||||
column · DisplayString · read-only · current The fiber type configured, currently only G.652 is supported. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewFiberDispComp | 1.3.6.1.4.1.30826.2.2.3.1.1.1.11 | Integer32 (-10000..10000) | RO | -667 | |||||||||||||
column · Integer32 (-10000..10000) · read-only · current The compensated dispersion value by the system in units of 1 ps/nm. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewFiberDispFinal | 1.3.6.1.4.1.30826.2.2.3.1.1.1.12 | Integer32 (-10000..10000) | RO | 0 | |||||||||||||
column · Integer32 (-10000..10000) · read-only · current Residiual(remaning) dispersion in units of 1 ps/nm. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewFiberUtilization | 1.3.6.1.4.1.30826.2.2.3.1.1.1.13 | Gauge32 (0..100) | RO | 5 | |||||||||||||
column · Gauge32 (0..100) · read-only · current Wavelength utilization of the system in units of %. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewRemotePower | 1.3.6.1.4.1.30826.2.2.3.1.1.1.14 | OpticalPower1Decimal | RO | -94 | |||||||||||||
column · OpticalPower1Decimal · read-only · current The optical power of the remote interface in units of 0.1 dBm. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewRemoteName | 1.3.6.1.4.1.30826.2.2.3.1.1.1.15 | DisplayString | RO | if-1/line-rx | |||||||||||||
column · DisplayString · read-only · current The remote interface name. If no interface this value is empty. if-c/channelid-direction where c = chassis and direction = rx or tx. Example values from LibreNMS test devices
| |||||||||||||||||
| CdcpLinkviewRemoteHostname | 1.3.6.1.4.1.30826.2.2.3.1.1.1.16 | DisplayString | RO | ols01-deco01.tingfiber.net | |||||||||||||
column · DisplayString · read-only · current The hostname of the remote system. Example values from LibreNMS test devices
| |||||||||||||||||
| NdcpLinkviewMIBCompliance | 1.3.6.1.4.1.30826.2.2.3.2 | ||||||||||||||||
| NdcpLinkviewMIBGroups | 1.3.6.1.4.1.30826.2.2.3.2.1 | ||||||||||||||||
| GdcpLinkviewTableGroupV1 | 1.3.6.1.4.1.30826.2.2.3.2.1.1 | ||||||||||||||||
group · current The interface table objects V1.
| |||||||||||||||||
| NdcpLinkviewMIBCompliances | 1.3.6.1.4.1.30826.2.2.3.2.2 | ||||||||||||||||
| MdcpLinkviewBasicComplV1 | 1.3.6.1.4.1.30826.2.2.3.2.2.1 | ||||||||||||||||
compliance · current Basic implementation requirements for the DCP-INTERFACE-MIB V1.
| |||||||||||||||||
Textual conventions
DcpFiberAttenuationUnsigned32 (0..10)Display hint:
d-2The fiber attenuation per km with 2 decimals.
DcpFiberLengthUnsigned32 (0..500)Display hint:
d-1The fiber length in km with 1 decimal.
DcpFiberLossUnsigned32 (0..1000)Display hint:
d-1The fiber loss in dB with 1 decimal.