NMS-OPTICAL-MIB
深圳凌特华盛科技有限公司(Shenzhen Smartbyte Technology Co., Ltd.)Define the optical module nodes.
snmptranslate -m NMS-OPTICAL-MIB -Tpsnmpwalk -v2c -c <community> -m NMS-OPTICAL-MIB <host> 1.3.6.1.4.1.56166.1.8.1Imports
| NMS | nmsModule |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Noptical | 1.3.6.1.4.1.56166.1.8 | ||||||||||||||||||||
| IopticalModule | 1.3.6.1.4.1.56166.1.8.1 | ||||||||||||||||||||
identity Define the optical module nodes. | |||||||||||||||||||||
| TopticalModuleInfoTable | 1.3.6.1.4.1.56166.1.8.2 | NA | |||||||||||||||||||
table · not-accessible · current This table describes optical module information. | |||||||||||||||||||||
| RopticalModuleInfoEntry | 1.3.6.1.4.1.56166.1.8.2.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the table of optical module properties for each optical module.
| |||||||||||||||||||||
| CopticalPortIndex | 1.3.6.1.4.1.56166.1.8.2.1.1 | INTEGER (0..65535) | RO | 1 | |||||||||||||||||
column · INTEGER (0..65535) · read-only · current Interface index(es) of port(s) present on the device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalTransceiverType | 1.3.6.1.4.1.56166.1.8.2.1.2 | OCTET STRING (SIZE (0..32)) | RO | | |||||||||||||||||
column · OCTET STRING (SIZE (0..32)) · read-only · current Type of the optical module, such as SFP/XFP/GBIC. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalConnectType | 1.3.6.1.4.1.56166.1.8.2.1.3 | OCTET STRING (SIZE (0..16)) | RO | | |||||||||||||||||
column · OCTET STRING (SIZE (0..16)) · read-only · current The Connector Type of the optical module, such as LC. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalWaveLength | 1.3.6.1.4.1.56166.1.8.2.1.4 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Wave length of the interface, measured in nanometer. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalVendorName | 1.3.6.1.4.1.56166.1.8.2.1.5 | OCTET STRING (SIZE (0..64)) | RO | | |||||||||||||||||
column · OCTET STRING (SIZE (0..64)) · read-only · current Vendor name of the optical module. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalSerialNumber | 1.3.6.1.4.1.56166.1.8.2.1.6 | OCTET STRING (SIZE (0..32)) | RO | | |||||||||||||||||
column · OCTET STRING (SIZE (0..32)) · read-only · current Serial number of the optical module. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalPartNumber | 1.3.6.1.4.1.56166.1.8.2.1.7 | OCTET STRING (SIZE (0..32)) | RO | | |||||||||||||||||
column · OCTET STRING (SIZE (0..32)) · read-only · current Part number of the optical module. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalTransferDistance | 1.3.6.1.4.1.56166.1.8.2.1.8 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current The maximum distance which the interface can transmit, measured in meter. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalSupportDDM | 1.3.6.1.4.1.56166.1.8.2.1.9 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current Indicates whether the optical module supports DDM.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalTemperature | 1.3.6.1.4.1.56166.1.8.2.1.10 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Indicating the current temperature. The unit is degrees Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalVoltage | 1.3.6.1.4.1.56166.1.8.2.1.11 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Indicating the current voltage. The unit is in hundredths of V. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalBiasCurrent | 1.3.6.1.4.1.56166.1.8.2.1.12 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Indicating the current bias electric current. The unit is in hundredths of mA. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalRxPower | 1.3.6.1.4.1.56166.1.8.2.1.13 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Indicating the received power. The unit is in hundredths of dBM. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalTxPower | 1.3.6.1.4.1.56166.1.8.2.1.14 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Indicating the transmitted power. The unit is in hundredths of dBM. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalTempHiAlarm | 1.3.6.1.4.1.56166.1.8.2.1.15 | Integer32 (-255..255) | RW | 0 | |||||||||||||||||
column · Integer32 (-255..255) · read-write · current Transceiver temperature too high alarm threshold limit in degrees Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalTempHiWarn | 1.3.6.1.4.1.56166.1.8.2.1.16 | Integer32 (-255..255) | RW | 0 | |||||||||||||||||
column · Integer32 (-255..255) · read-write · current Transceiver temperature too high warning threshold limit in degrees Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalTempLoWarn | 1.3.6.1.4.1.56166.1.8.2.1.17 | Integer32 (-255..255) | RW | 0 | |||||||||||||||||
column · Integer32 (-255..255) · read-write · current Transceiver temperature too low warning threshold limit in degrees Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalTempLoAlarm | 1.3.6.1.4.1.56166.1.8.2.1.18 | Integer32 (-255..255) | RW | 0 | |||||||||||||||||
column · Integer32 (-255..255) · read-write · current Transceiver temperature too low alarm threshold limit in degrees Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalVoltHiAlarm | 1.3.6.1.4.1.56166.1.8.2.1.19 | Integer32 (0..500) | RW | 0 | |||||||||||||||||
column · Integer32 (0..500) · read-write · current Transceiver voltage too high alarm threshold limit in hundredths of V. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalVoltHiWarn | 1.3.6.1.4.1.56166.1.8.2.1.20 | Integer32 (0..500) | RW | 0 | |||||||||||||||||
column · Integer32 (0..500) · read-write · current Transceiver voltage too high warning threshold limit in hundredths of V. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalVoltLoWarn | 1.3.6.1.4.1.56166.1.8.2.1.21 | Integer32 (0..500) | RW | 0 | |||||||||||||||||
column · Integer32 (0..500) · read-write · current Transceiver voltage too low warning threshold limit in hundredths of V. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalVoltLoAlarm | 1.3.6.1.4.1.56166.1.8.2.1.22 | Integer32 (0..500) | RW | 0 | |||||||||||||||||
column · Integer32 (0..500) · read-write · current Transceiver voltage too low alarm threshold limit in hundredths of V. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalBiasHiAlarm | 1.3.6.1.4.1.56166.1.8.2.1.23 | Integer32 (0..50000) | RW | 0 | |||||||||||||||||
column · Integer32 (0..50000) · read-write · current Transceiver bias too high alarm threshold limit in hundredths of mA. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalBiasHiWarn | 1.3.6.1.4.1.56166.1.8.2.1.24 | Integer32 (0..50000) | RW | 0 | |||||||||||||||||
column · Integer32 (0..50000) · read-write · current Transceiver bias too high warning threshold limit in hundredths of mA. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalBiasLoWarn | 1.3.6.1.4.1.56166.1.8.2.1.25 | Integer32 (0..50000) | RW | 0 | |||||||||||||||||
column · Integer32 (0..50000) · read-write · current Transceiver bias too low warning threshold limit in hundredths of mA. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalBiasLoAlarm | 1.3.6.1.4.1.56166.1.8.2.1.26 | Integer32 (0..50000) | RW | 0 | |||||||||||||||||
column · Integer32 (0..50000) · read-write · current Transceiver bias too low alarm threshold limit in hundredths of mA. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalRxHiAlarm | 1.3.6.1.4.1.56166.1.8.2.1.27 | Integer32 (-4000..1000) | RW | 0 | |||||||||||||||||
column · Integer32 (-4000..1000) · read-write · current Transceiver receive power too high alarm threshold limit in hundredths of dBM. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalRxHiWarn | 1.3.6.1.4.1.56166.1.8.2.1.28 | Integer32 (-4000..1000) | RW | 0 | |||||||||||||||||
column · Integer32 (-4000..1000) · read-write · current Transceiver receive power too high warning threshold limit in hundredths of dBM. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalRxLoWarn | 1.3.6.1.4.1.56166.1.8.2.1.29 | Integer32 (-4000..1000) | RW | 0 | |||||||||||||||||
column · Integer32 (-4000..1000) · read-write · current Transceiver receive power too low warning threshold limit in hundredths of dBM. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalRxLoAlarm | 1.3.6.1.4.1.56166.1.8.2.1.30 | Integer32 (-4000..1000) | RW | 0 | |||||||||||||||||
column · Integer32 (-4000..1000) · read-write · current Transceiver receive power too low alarm threshold limit in hundredths of dBM. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalTxHiAlarm | 1.3.6.1.4.1.56166.1.8.2.1.31 | Integer32 (-4000..1000) | RW | 0 | |||||||||||||||||
column · Integer32 (-4000..1000) · read-write · current Transceiver transmit power too high alarm threshold limit in hundredths of dBM. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalTxHiWarn | 1.3.6.1.4.1.56166.1.8.2.1.32 | Integer32 (-4000..1000) | RW | 0 | |||||||||||||||||
column · Integer32 (-4000..1000) · read-write · current Transceiver transmit power too high warning threshold limit in hundredths of dBM. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalTxLoWarn | 1.3.6.1.4.1.56166.1.8.2.1.33 | Integer32 (-4000..1000) | RW | 0 | |||||||||||||||||
column · Integer32 (-4000..1000) · read-write · current Transceiver transmit power too low warning threshold limit in hundredths of dBM. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CopticalTxLoAlarm | 1.3.6.1.4.1.56166.1.8.2.1.34 | Integer32 (-4000..1000) | RW | 0 | |||||||||||||||||
column · Integer32 (-4000..1000) · read-write · current Transceiver transmit power too low alarm threshold limit in hundredths of dBM. Example values from LibreNMS test devices
| |||||||||||||||||||||