SIAE-SFP-MIB
SIAE Microelettronica S.p.A.This MIB contains objects & alarms for a SFP
(Small Form-Factor Pluggable) module.
Reference documentation:
1) Small Form-factor Pluggable (SFP) Transceiver MultiSource
Agreement (MSA)
2) Finisar's Application Note AN-2030, Rev. D.
3) SFF 8472 - Diagnostic Monitoring Interface for Optical
Transceivers
Rev 12.2 November 21, 2014
4) SFF 8024 - SFF Cross Reference to Industry Products
Rev 4.0 June 27, 2016snmptranslate -m SIAE-SFP-MIB -Tpsnmpwalk -v2c -c <community> -m SIAE-SFP-MIB <host> 1.3.6.1.4.1.3373.1103.74Imports
| SIAE-ALARM-MIB | AlarmSeverityCode, AlarmStatus |
|---|---|
| SIAE-TREE-MIB | siaeMib |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION, TruthValue |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Isfp | 1.3.6.1.4.1.3373.1103.74 | ||||||||||||||||||||
identity This MIB contains objects & alarms for a SFP
(Small Form-Factor Pluggable) module.
Reference documentation:
1) Small Form-factor Pluggable (SFP) Transceiver MultiSource
Agreement (MSA)
2) Finisar's Application Note AN-2030, Rev. D.
3) SFF 8472 - Diagnostic Monitoring Interface for Optical
Transceivers
Rev 12.2 November 21, 2014
4) SFF 8024 - SFF Cross Reference to Industry Products
Rev 4.0 June 27, 2016 | |||||||||||||||||||||
| SsfpMibVersion | 1.3.6.1.4.1.3373.1103.74.1 | INTEGER | RO | 10002 | |||||||||||||||||
scalar · INTEGER · read-only · current Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TsfpSerialIdTable | 1.3.6.1.4.1.3373.1103.74.2 | NA | |||||||||||||||||||
table · not-accessible · current Each SFP contains a 95+32 byte block of ID data fields. This table contains the items found in this data block. Fields in this data block is filled in by the SFP manufactor. The table shows the contents of this data block without further processing. | |||||||||||||||||||||
| RsfpSerialIdEntry | 1.3.6.1.4.1.3373.1103.74.2.1 | NA | |||||||||||||||||||
| CsfpModuleId | 1.3.6.1.4.1.3373.1103.74.2.1.1 | Integer32 | RO | 1 | |||||||||||||||||
column · Integer32 · read-only · current This index identifies a unique SFP module in the system Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpSerialIdValid | 1.3.6.1.4.1.3373.1103.74.2.1.2 | TruthValue | RO | 1 | |||||||||||||||||
column · TruthValue · read-only · current When false the SFP data in this table is not valid. This will be set to False if the SFP module is not installed or if the EEPROM check code is wrong. The data in this table should not be used unless this element is True. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpVendorName | 1.3.6.1.4.1.3373.1103.74.2.1.3 | OCTET STRING (SIZE (0..16)) | RO | Cambium Networks | |||||||||||||||||
column · OCTET STRING (SIZE (0..16)) · read-only · current The SFP vendor name. Located at I2C address 0xa0, bytes: 20 - 35 Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpVendorPartNumber | 1.3.6.1.4.1.3373.1103.74.2.1.4 | OCTET STRING (SIZE (0..16)) | RO | SFP-10G-LR | |||||||||||||||||
column · OCTET STRING (SIZE (0..16)) · read-only · current The SFP vendor part number. Located at I2C address 0xa0, bytes: 40 - 55 Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpVendorRev | 1.3.6.1.4.1.3373.1103.74.2.1.5 | OCTET STRING (SIZE (0..4)) | RO | A | |||||||||||||||||
column · OCTET STRING (SIZE (0..4)) · read-only · current The SFP vendor's product revision number. Located at I2C address 0xa0, bytes: 56 - 59 Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpVendorSN | 1.3.6.1.4.1.3373.1103.74.2.1.6 | OCTET STRING (SIZE (0..16)) | RO | S2202220799 | |||||||||||||||||
column · OCTET STRING (SIZE (0..16)) · read-only · current The SFP vendor serial number. Located at I2C address 0xa0, bytes: 68 - 83 Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpVendorDateCode | 1.3.6.1.4.1.3373.1103.74.2.1.7 | OCTET STRING (SIZE (0..8)) | RO | 220323 | |||||||||||||||||
column · OCTET STRING (SIZE (0..8)) · read-only · current The SFP vendor date code.
Format: YYMMDDLL
- YY: year, 00 = 2000
- MM: month, 01 = January
- DD_ day, 01 to 31
- LL: vendor lot code, or blank.
Located at I2C address 0xa0, bytes: 84 - 91Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpDiagMonitorCode | 1.3.6.1.4.1.3373.1103.74.2.1.8 | Bits | RO | h | |||||||||||||||||
column · Bits · read-only · current This indicates which type of diagnostic monitoring is
implemented (if any) in the SFP.
-bit 7: = 0 legacy diagnostic implementations (should be 0)
-bit 6: = 1 digital diagnostic monitoring implemented (should be 1)
-bit 5: = 1 internal calibration
-bit 4: = 1 external calibration mask
-bit 3: = 0 OMA received power measurment,
= 1 average received power
-bit 2: = 1 I2C addressing option.
Located at I2C address 0xa0, byte: 92
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpEnhancedOptionsCode | 1.3.6.1.4.1.3373.1103.74.2.1.9 | Bits | RO | ? | |||||||||||||||||
column · Bits · read-only · current This indicates which optional enhanced features are implemented (if any) in the SFP. Located at I2C address 0xa0, byte: 93
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpOptions | 1.3.6.1.4.1.3373.1103.74.2.1.10 | Bits | RO | h | |||||||||||||||||
column · Bits · read-only · current Implemented transceiver options: -bit 5: = 1 RATE_SELECT implemented. -bit 4: = 1 TX_DISABLE implemented -bit 3: = 1 TX_FAULT implemented -bit 2: = 1 LOS Implemented, inverted -bit 1: = 1 LOS Implemented Located at I2C address 0xa0, byte: 65
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpFibreChannelMedia | 1.3.6.1.4.1.3373.1103.74.2.1.11 | Bits | RO | 00 | |||||||||||||||||
column · Bits · read-only · current Fiber Channel transmission media. Located at I2C address 0xa0, byte: 9
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpCompliance | 1.3.6.1.4.1.3373.1103.74.2.1.12 | Bits | RO | 00:00:00 | |||||||||||||||||
column · Bits · read-only · current Electronic or optical interfaces that are supported by the transceiver. Located at I2C address 0xa0, bytes: 4,5 & 6
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpWavelength | 1.3.6.1.4.1.3373.1103.74.2.1.13 | Integer32 | RO | 1310 | |||||||||||||||||
column · Integer32 · read-only · current Nominal transmiter output wavelength at room temperature. Units are in nm (nanometers). Located at I2C address 0xa0, bytes: 60 & 61 (endianess: big)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpNominalBitRate | 1.3.6.1.4.1.3373.1103.74.2.1.14 | Integer32 | RO | 10300 | |||||||||||||||||
column · Integer32 · read-only · current Nominal bit rate (in megabit per second) supported from this SFP module rouded to the nearest 100 megabits per second. Located at I2C address 0xa0, byte: 12 Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpLinkLength9u | 1.3.6.1.4.1.3373.1103.74.2.1.15 | Integer32 | RO | 10000 | |||||||||||||||||
column · Integer32 · read-only · current Link length (in meters) supported from this SFP module while operating in compliance with the applicable standards using single mode fiber. A value of zero means that the transceiver does not support single mode fiber. Located at I2C address 0xa0, bytes: 14-15
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpLinkLength50u | 1.3.6.1.4.1.3373.1103.74.2.1.16 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Link length (in meters) supported from this SFP module while operating in compliance with the applicable standards using 50 micron multi-mode fiber. A value of zero means that the transceiver does not support 50 micron multi-mode mode fiber. Located at I2C address 0xa0, byte: 16
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpLinkLength62u5 | 1.3.6.1.4.1.3373.1103.74.2.1.17 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Link length (in meters) supported from this SFP module while operating in compliance with the applicable standards using 62.5 micron multi-mode fiber. A value of zero means that the transceiver does not support 62.5 micron multi-mode mode fiber. Located at I2C address 0xa0, byte: 17
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpLinkLengthCopper | 1.3.6.1.4.1.3373.1103.74.2.1.18 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Link length (in meters) supported from this SFP module while operating in compliance with the applicable standards using copper cable. A value of zero means that the transceiver does not support copper cable. Located at I2C address 0xa0, byte: 18
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpLabel | 1.3.6.1.4.1.3373.1103.74.2.1.19 | DisplayString (SIZE (0..32)) | RO | Physical Interface 1 | |||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current This is an ASCII string that identifies this SFP in the system. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpFailAlarm | 1.3.6.1.4.1.3373.1103.74.2.1.20 | AlarmStatus | RO | 1 | |||||||||||||||||
column · AlarmStatus · read-only · current SFP Module fail (module missing included) Example values from LibreNMS test devices
| |||||||||||||||||||||
| SsfpFailAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.74.6 | AlarmSeverityCode | RW | 21 | |||||||||||||||||
scalar · AlarmSeverityCode · read-write · current Defines the severity associated to the sfpFailAlarm and enables/disables the trap generation on status change event. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TsfpDiagnosticTable | 1.3.6.1.4.1.3373.1103.74.7 | NA | |||||||||||||||||||
table · not-accessible · current Each SFP may contain a 256 byte block of diagnostic data fields. This table contains the items found in this data block. The data block is located at I2C address 0xa2. | |||||||||||||||||||||
| RsfpDiagnosticEntry | 1.3.6.1.4.1.3373.1103.74.7.1 | NA | |||||||||||||||||||
| CsfpDiagnosticValid | 1.3.6.1.4.1.3373.1103.74.7.1.1 | TruthValue | RO | 1 | |||||||||||||||||
column · TruthValue · read-only · current if False, then the SFP data in this table is not valid. This will be set to False if the SFP module is not installed, or if the I/O card that contains the SFP is not installed or if the EEPROM check code is wrong. The data in the table should not be used unless this element is True. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpLOSPinOut | 1.3.6.1.4.1.3373.1103.74.7.1.2 | TruthValue | RO | 1 | |||||||||||||||||
column · TruthValue · read-only · current This contains the T/F state of the SFP LOS (output) pin. It is True if the SFP has detected Loss-Of-Signal. located at I2c address 0xa2, address: 110, mask 0x02 Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpTxFaultPinOut | 1.3.6.1.4.1.3373.1103.74.7.1.3 | TruthValue | RO | 2 | |||||||||||||||||
column · TruthValue · read-only · current This contains the T/F state of the SFP Tx Fault (output) pin. It is True if the SFP has detected a Tx fault condition. located at I2C address 0xa2, Byte 110, mask 0x04 Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpRateSelectPinIn | 1.3.6.1.4.1.3373.1103.74.7.1.4 | TruthValue | RO | 1 | |||||||||||||||||
column · TruthValue · read-only · current This contains the T/F state of the SFP RX Rate Select (input) pin. This function is not implemented on Finisar SFPs. located at I2C address 0xa2, Byte 110, mask 0x10 Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpTxDisablePinIn | 1.3.6.1.4.1.3373.1103.74.7.1.5 | TruthValue | RO | 1 | |||||||||||||||||
column · TruthValue · read-only · current This contains the T/F state of the SFP TX Disable (input) pin. located at I2C address 0xa2, Byte 110, mask 0x80 Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpTemperature | 1.3.6.1.4.1.3373.1103.74.7.1.6 | Temperature | RO | 565 | |||||||||||||||||
column · Temperature · read-only · current This contains the internal temperature of the SFP in tehnth of Celsius degrees. Range is from -128.0C to +128.0C, but is only valid from -40.0C to +125.0C with an accuracy of +/- 3C. Located at I2C address 0xa2, Bytes 96 & 97 (MSB, LSB)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpVoltage | 1.3.6.1.4.1.3373.1103.74.7.1.7 | Integer32 (0..65535) | RO | 3319 | |||||||||||||||||
column · Integer32 (0..65535) · read-only · current This contains the internally measured SFP supply voltage (Vcc). Units are in milliVolts (3210 = 3.21V). Range is 0 to 6.554V. Located at I2C address 0xa2, Bytes 98 & 99 (MSB, LSB)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpTxBias | 1.3.6.1.4.1.3373.1103.74.7.1.8 | Integer32 (0..131000) | RO | 0 | |||||||||||||||||
column · Integer32 (0..131000) · read-only · current This contains the internally measured SFP TX laser bias current. Units are in microAmps, and range from 0 to 131000uA (131mA). Located at I2C address 0xa2, Bytes 100 & 101 (MSB, LSB)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpTxPower | 1.3.6.1.4.1.3373.1103.74.7.1.9 | Integer32 (0..65535) | RO | 0 | |||||||||||||||||
column · Integer32 (0..65535) · read-only · current This contains the internally measured TX output power. Units are in uW (micro Watts), and range from 0 to 6554uW (6.535mW). This value is not valid if the transmitter is disabled. Located at I2C address 0xa2, Bytes 102 & 103 (MSB, LSB)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpRxPower | 1.3.6.1.4.1.3373.1103.74.7.1.10 | Integer32 (0..65535) | RO | 0 | |||||||||||||||||
column · Integer32 (0..65535) · read-only · current This contains the internally measured RX optical power. Units are in uW (micro Watts), and range from 0 to 6554uW (6.535mW). Located at I2C address 0xa2, Bytes 104 & 105 (MSB, LSB)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpInternalAlarms | 1.3.6.1.4.1.3373.1103.74.7.1.11 | Bits | RO | 00:40 | |||||||||||||||||
column · Bits · read-only · current This contains the state of the SFP internal alarm register. A bit is set for each alarm that is active. located at I2C address 0xa2, Byte 112 & 113 (MSB, LSB) mask 0xffc0
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpInternalWarnings | 1.3.6.1.4.1.3373.1103.74.7.1.12 | Bits | RO | 00:40 | |||||||||||||||||
column · Bits · read-only · current This contains the state of the SFP internal warning register. A bit is set for each warning that is active. located at I2C address 0xa2, Byte 116 & 117 (MSB, LSB) mask 0xffc0
Example values from LibreNMS test devices
| |||||||||||||||||||||
| TsfpAlarmTable | 1.3.6.1.4.1.3373.1103.74.10 | NA | |||||||||||||||||||
table · not-accessible · current This table contains the SFP alarm and warning threshold values. | |||||||||||||||||||||
| RsfpAlarmEntry | 1.3.6.1.4.1.3373.1103.74.10.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry into the Threshold table. | |||||||||||||||||||||
| CsfpPhysicalQuantity | 1.3.6.1.4.1.3373.1103.74.10.1.1 | PhysicalQuantity | RO | 1 | |||||||||||||||||
column · PhysicalQuantity · read-only · current Measured physical quantity. Units of temperature are tenth of Celsius degrres, units of Power supply voltage (Vcc) are microVolts, units of Tx laser bias current are microAmps (uA), units of Rx optical power are microWatts (uW), units of Tx output power are microWatts (uW). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpThresholdHighAlarm | 1.3.6.1.4.1.3373.1103.74.10.1.2 | Integer32 | RO | 1000 | |||||||||||||||||
column · Integer32 · read-only · current A reading at or above this temperature will trigger a high measured physical quantity alarm. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpThresholdHighWarning | 1.3.6.1.4.1.3373.1103.74.10.1.3 | Integer32 | RO | 950 | |||||||||||||||||
column · Integer32 · read-only · current A reading at or above this temperature will trigger a high measured physical quantity warning. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpThresholdLowAlarm | 1.3.6.1.4.1.3373.1103.74.10.1.4 | Integer32 | RO | -500 | |||||||||||||||||
column · Integer32 · read-only · current A reading at or above this temperature will trigger a low measured physical quantity alarm. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpThresholdLowWarning | 1.3.6.1.4.1.3373.1103.74.10.1.5 | Integer32 | RO | -450 | |||||||||||||||||
column · Integer32 · read-only · current A reading at or above this temperature will trigger a low measured physical quantity warning. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpHighAlarm | 1.3.6.1.4.1.3373.1103.74.10.1.6 | AlarmStatus | RO | 1 | |||||||||||||||||
column · AlarmStatus · read-only · current Measured physical quantity has crossed sfpThresholdHighAlarm. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpHighWarningAlarm | 1.3.6.1.4.1.3373.1103.74.10.1.7 | AlarmStatus | RO | 1 | |||||||||||||||||
column · AlarmStatus · read-only · current Measured physical quantity has crossed sfpThresholdHighWarning. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpLowAlarm | 1.3.6.1.4.1.3373.1103.74.10.1.8 | AlarmStatus | RO | 1 | |||||||||||||||||
column · AlarmStatus · read-only · current Measured physical quantity has crossed sfpThresholdLowAlarm. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsfpLowWarningAlarm | 1.3.6.1.4.1.3373.1103.74.10.1.9 | AlarmStatus | RO | 1 | |||||||||||||||||
column · AlarmStatus · read-only · current Measured physical quantity has crossed sfpThresholdLowWarning. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SsfpHighAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.74.11 | AlarmSeverityCode | RW | 21 | |||||||||||||||||
scalar · AlarmSeverityCode · read-write · current Defines the severity associated to the sfpHighAlarm and enables/disables the trap generation on status change event. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SsfpHighWarningAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.74.12 | AlarmSeverityCode | RW | 19 | |||||||||||||||||
scalar · AlarmSeverityCode · read-write · current Defines the severity associated to the sfpHighWarningAlarm and enables/disables the trap generation on status change event. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SsfpLowAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.74.13 | AlarmSeverityCode | RW | 21 | |||||||||||||||||
scalar · AlarmSeverityCode · read-write · current Defines the severity associated to the sfpLowAlarm and enables/disables the trap generation on status change event. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SsfpLowWarningAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.74.14 | AlarmSeverityCode | RW | 19 | |||||||||||||||||
scalar · AlarmSeverityCode · read-write · current Defines the severity associated to the sfpLowWarningAlarm and enables/disables the trap generation on status change event. Example values from LibreNMS test devices
| |||||||||||||||||||||
Textual conventions
PhysicalQuantityINTEGERphyQtRxPower(5)phyQtTemperature(1)phyQtTxBias(3)phyQtTxPower(4)phyQtVoltage(2)Measured physical quantity
TemperatureInteger32 (-2000..2000)Temperature in tenth of degrees C