SIAE-POWER-SUPPLY-MIB
SIAE Microelettronica S.p.A.SIAE's Power Supply MIB.
snmptranslate -m SIAE-POWER-SUPPLY-MIB -Tpsnmpwalk -v2c -c <community> -m SIAE-POWER-SUPPLY-MIB <host> 1.3.6.1.4.1.3373.1103.89Imports
| SIAE-ALARM-MIB | AlarmSeverityCode, AlarmStatus |
|---|---|
| SIAE-TREE-MIB | siaeMib |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, RowStatus, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IpwrSupply | 1.3.6.1.4.1.3373.1103.89 | ||||||||||||||||||||
identity SIAE's Power Supply MIB. | |||||||||||||||||||||
| SpwrSupplyMibVersion | 1.3.6.1.4.1.3373.1103.89.1 | INTEGER | RO | 10000 | |||||||||||||||||
scalar · INTEGER · read-only · current Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TpwrSupplyTable | 1.3.6.1.4.1.3373.1103.89.2 | NA | |||||||||||||||||||
table · not-accessible · current Table with SIAE's Power Supply Entries. | |||||||||||||||||||||
| RpwrSupplyTableEntry | 1.3.6.1.4.1.3373.1103.89.2.1 | NA | |||||||||||||||||||
row · not-accessible · current SIAE's Power Supply entris. There is an entry for each power supply unit in the device.
| |||||||||||||||||||||
| CpwrSupplyIndex | 1.3.6.1.4.1.3373.1103.89.2.1.1 | Integer32 | NA | ||||||||||||||||||
column · Integer32 · not-accessible · current A unique value, greater than zero, for each power supply unit. | |||||||||||||||||||||
| CpwrSupplyRowStatus | 1.3.6.1.4.1.3373.1103.89.2.1.2 | RowStatus | RC | 1 | |||||||||||||||||
column · RowStatus · read-create · current Status of this row of pwrSupplyTable. A manager should not set this object. It is used by the agent to create relevant rows, depending on the HW configuration. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpwrSupplyLabel | 1.3.6.1.4.1.3373.1103.89.2.1.3 | DisplayString (SIZE (0..63)) | RO | CABLE 48V | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · current A textual string containing information about the power supply unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpwrSupplyAdminStatus | 1.3.6.1.4.1.3373.1103.89.2.1.4 | INTEGER | RC | disable(1) | |||||||||||||||||
column · INTEGER · read-create · current The desired state of the Power supply. Only devices that allow the shutdown of a power supply accept the value disable(1). This object can be set only when the pwrSupplyRowStatus is active. Default value alfoplus2, alfo80hdx: disable Default value other equipment: enable
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpwrSupplyAlarm | 1.3.6.1.4.1.3373.1103.89.2.1.5 | AlarmStatus | RO | 1 | |||||||||||||||||
column · AlarmStatus · read-only · current The power supply has failed. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpwrSupplyAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.89.3 | AlarmSeverityCode | RW | 5 | |||||||||||||||||
scalar · AlarmSeverityCode · read-write · current Defines the severity associated to the pwrSupplyAlarm and enables/disables the trap generation on status change event. Example values from LibreNMS test devices
| |||||||||||||||||||||