SIAE-MANOP-MIB
SIAE Microelettronica S.p.A.Manual Operation management.
snmptranslate -m SIAE-MANOP-MIB -Tpsnmpwalk -v2c -c <community> -m SIAE-MANOP-MIB <host> 1.3.6.1.4.1.3373.1103.71Imports
| SIAE-ALARM-MIB | AlarmSeverityCode, AlarmStatus |
|---|---|
| SIAE-TREE-MIB | siaeMib |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ImanualOperation | 1.3.6.1.4.1.3373.1103.71 | ||||||||||||
identity Manual Operation management. | |||||||||||||
| NmanualOpTrap | 1.3.6.1.4.1.3373.1103.71.0 | ||||||||||||
| SmanualOpMibVersion | 1.3.6.1.4.1.3373.1103.71.1 | INTEGER | RO | 10000 | |||||||||
scalar · INTEGER · read-only · current Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01. Example values from LibreNMS test devices
| |||||||||||||
| TmanualOpTable | 1.3.6.1.4.1.3373.1103.71.2 | NA | |||||||||||
table · not-accessible · current Table with manual operation record. | |||||||||||||
| RmanualOpRecord | 1.3.6.1.4.1.3373.1103.71.2.1 | NA | |||||||||||
| CmanualOpId | 1.3.6.1.4.1.3373.1103.71.2.1.1 | Integer32 | RO | ||||||||||
column · Integer32 · read-only · current Manual operation index. | |||||||||||||
| CmanualOpObjectId | 1.3.6.1.4.1.3373.1103.71.2.1.2 | OBJECT IDENTIFIER | RO | ||||||||||
column · OBJECT IDENTIFIER · read-only · current Object identifier of the manual operation active element. | |||||||||||||
| CmanualOpEventTime | 1.3.6.1.4.1.3373.1103.71.2.1.3 | Unsigned32 | RO | ||||||||||
column · Unsigned32 · read-only · current The time (in seconds since 01-Gen-1970) when the event was registered in the table. | |||||||||||||
| CmanualOpValueType | 1.3.6.1.4.1.3373.1103.71.2.1.4 | INTEGER | RO | ||||||||||
column · INTEGER · read-only · current The type of the value. One and only one of the value object that follow is used for a given row in this table, based on this type.
| |||||||||||||
| CmanualOpIntegerVal | 1.3.6.1.4.1.3373.1103.71.2.1.5 | Integer32 | RO | ||||||||||
column · Integer32 · read-only · current The value when manualOpValueType is 'integer32'. | |||||||||||||
| CmanualOpOidVal | 1.3.6.1.4.1.3373.1103.71.2.1.6 | OBJECT IDENTIFIER | RO | ||||||||||
column · OBJECT IDENTIFIER · read-only · current The value when manualOpValueType is 'objectId'. | |||||||||||||
| SmanualOpActive | 1.3.6.1.4.1.3373.1103.71.3 | AlarmStatus | RO | 1 | |||||||||
scalar · AlarmStatus · read-only · current Manual Operation active on the equipment. Example values from LibreNMS test devices
| |||||||||||||
| SmanualOpActiveSeverityCode | 1.3.6.1.4.1.3373.1103.71.4 | AlarmSeverityCode | RW | 3 | |||||||||
scalar · AlarmSeverityCode · read-write · current Defines the severity associated to manualOpActive and enables/disables the trap generation on status change event. Example values from LibreNMS test devices
| |||||||||||||
| SmanualOpTimeOut | 1.3.6.1.4.1.3373.1103.71.5 | INTEGER (0..172800) | RW | 2 | |||||||||
scalar · INTEGER (0..172800) · read-write · current This object defines the time (in seconds) after wich the manual operations are cleared. The maximum value is equivalent to 48 hours. A zero means no Time-out. Example values from LibreNMS test devices
| |||||||||||||