SIAE-EQUIP-MIB
SIAE Microelettronica S.p.A.Common parameters of SIAE equipments.
snmptranslate -m SIAE-EQUIP-MIB -Tpsnmpwalk -v2c -c <community> -m SIAE-EQUIP-MIB <host> 1.3.6.1.4.1.3373.1103.1Imports
| IF-MIB | InterfaceIndex |
|---|---|
| SIAE-ALARM-MIB | AlarmSeverityCode, AlarmStatus, alarmTrap |
| SIAE-EQUIPTYPE-MIB | equipTypeUnknown |
| SIAE-TREE-MIB | siaeMib |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | AutonomousType, DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| !equipLOMConnectedMonitor | 1.3.6.1.4.1.3373.1103.0.109 | ||||||||||||||||
notification · current This event is generated by ALFOHD-NE when equipLOMConnected is set to Monitor mode. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMConnected | |||||||||||||||||
| !equipLOMConnectedConfig | 1.3.6.1.4.1.3373.1103.0.110 | ||||||||||||||||
notification · current This event is generated by ALFOHD-NE when equipLOMConnected is set to Configuration mode. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMConnected | |||||||||||||||||
| !equipLOMDisconnected | 1.3.6.1.4.1.3373.1103.0.111 | ||||||||||||||||
notification · current This event is generated by ALFOHD-NE when LOMConnected is cleared. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMConnected | |||||||||||||||||
| !equipConfigChangeStatus | 1.3.6.1.4.1.3373.1103.0.114 | ||||||||||||||||
notification · current This event is generated by ALFOHD-NE when equipConfigChange is changed. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipConfigChange | |||||||||||||||||
| !equipManagerWakeUpNotify | 1.3.6.1.4.1.3373.1103.0.123 | ||||||||||||||||
notification · current This trap is sent periodically only to the manager specified by the leaf equipManagerWakeUpIpAddr when equipManagerWakeUpAlarmSeverityCode differs from disable. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipStationID 3) equipLocation 4) equipIpSnmpAgentAddress 5) equipGosipAddress 6) equipManagerWakeUpIpAddr 7) equipManagerWakeUpAlarm | |||||||||||||||||
| Iequipment | 1.3.6.1.4.1.3373.1103.1 | ||||||||||||||||
identity Common parameters of SIAE equipments. | |||||||||||||||||
| SequipMibVersion | 1.3.6.1.4.1.3373.1103.1.1 | INTEGER | RO | 10005 | |||||||||||||
scalar · INTEGER · read-only · current Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipCurrentTime | 1.3.6.1.4.1.3373.1103.1.2 | TimeTicks | RW | 1735944163 (200d 22h 4m 1s) | |||||||||||||
scalar · TimeTicks · read-write · current Seconds since 1/1/1970. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipUpTime | 1.3.6.1.4.1.3373.1103.1.3 | TimeTicks | RO | 1734737120 (200d 18h 42m 51s) | |||||||||||||
scalar · TimeTicks · read-only · current The time since the system was last re-initialized (in seconds since 1/1/1970). Example values from LibreNMS test devices
| |||||||||||||||||
| SequipType | 1.3.6.1.4.1.3373.1103.1.4 | AutonomousType | RO | 1.3.6.1.4.1.3373.1103.1.5.79 | |||||||||||||
scalar · AutonomousType · read-only · current Type of SIAE MICROELETTRONICA's equipment Example values from LibreNMS test devices
| |||||||||||||||||
| SequipIpEthOsiAddress | 1.3.6.1.4.1.3373.1103.1.6 | IpAddress | RW | 0.0.0.0 | |||||||||||||
scalar · IpAddress · read-write · current Ip address of the equipment on Ethernet-OSI interface. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipGosipAddress | 1.3.6.1.4.1.3373.1103.1.7 | OCTET STRING (SIZE (0..20)) | RW | | |||||||||||||
scalar · OCTET STRING (SIZE (0..20)) · read-write · current GOSIP address of the equipment. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipIpEthOsiNetMask | 1.3.6.1.4.1.3373.1103.1.8 | IpAddress | RW | 255.255.255.0 | |||||||||||||
scalar · IpAddress · read-write · current The subnet Mask associated with the IP address of OSI ethernet interface. The value of the Mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipL1L2IsIsRouting | 1.3.6.1.4.1.3373.1103.1.9 | INTEGER | RW | 0 | |||||||||||||
scalar · INTEGER · read-write · current It defines the IS-IS routing type: L1 within the same area, L2 among different areas.
Example values from LibreNMS test devices
| |||||||||||||||||
| SequipStationID | 1.3.6.1.4.1.3373.1103.1.10 | DisplayString (SIZE (0..63)) | RW | ALFO80HDX | |||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-write · current ASCII string assigned by the operator to identify the specific equipment. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipLOMConfigEnable | 1.3.6.1.4.1.3373.1103.1.11 | INTEGER | RW | enable(2) | |||||||||||||
scalar · INTEGER · read-write · current Enables/disables the capabilityto connect a LOM in Configuration Mode.
Example values from LibreNMS test devices
| |||||||||||||||||
| SequipLOMConnected | 1.3.6.1.4.1.3373.1103.1.12 | INTEGER | RO | connectionAsConfig(3) | |||||||||||||
scalar · INTEGER · read-only · current Signal when the LOM is connected to the NE and if the connection is for monitor or configuration.
Example values from LibreNMS test devices
| |||||||||||||||||
| SequipLOMConnectedTrapEnable | 1.3.6.1.4.1.3373.1103.1.13 | INTEGER | RW | trapEnable(2) | |||||||||||||
scalar · INTEGER · read-write · current Enables/disables the trap generation on EquipLOMConnected status change event.
Example values from LibreNMS test devices
| |||||||||||||||||
| SequipConfigChange | 1.3.6.1.4.1.3373.1103.1.14 | OCTET STRING (SIZE (6)) | RW | 00:00:00:00:00:00 | |||||||||||||
scalar · OCTET STRING (SIZE (6)) · read-write · current Set by the NE when the equipment configuration is changed by the local or Remote LOM. The octet string is a bit stream of flags; a set bit is a change on a specific item. We had: Byte 0.7: change in configuration for equipment group Byte 0.6: change in configuration for userInput group Byte 0.5: change in configuration for userOutput group Byte 0.4: change in configuration for alarmLog group ...... Byte 3.7: change in a severity for equipment group Byte 3.6: change in a severity for userInput group Byte 3.5: change in a severity for userOutput group Byte 3.4: change in a severity for alarmLog group CEM can reset the change condition writing one to desired bit flag ...... Example values from LibreNMS test devices
| |||||||||||||||||
| SequipConfigChangeTrapEnable | 1.3.6.1.4.1.3373.1103.1.15 | INTEGER | RW | trapEnable(2) | |||||||||||||
scalar · INTEGER · read-write · current Enables/disables the trap generation on EquipConfigChange status change event.
Example values from LibreNMS test devices
| |||||||||||||||||
| SequipRequest | 1.3.6.1.4.1.3373.1103.1.16 | INTEGER | RW | notActive(0) | |||||||||||||
scalar · INTEGER · read-write · current Force Equipment Controller restart or change in interface properties.
Example values from LibreNMS test devices
| |||||||||||||||||
| SequipIpEthAddress | 1.3.6.1.4.1.3373.1103.1.17 | IpAddress | RW | 10.250.0.110 | |||||||||||||
scalar · IpAddress · read-write · current Ip address of the equipment on Ethernet interface. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipIpEthNetMask | 1.3.6.1.4.1.3373.1103.1.18 | IpAddress | RW | 255.255.255.0 | |||||||||||||
scalar · IpAddress · read-write · current The subnet Mask associated with the IP address of ethernet interface. The value of the Mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipOsiamParameter | 1.3.6.1.4.1.3373.1103.1.19 | OCTET STRING (SIZE (0..41)) | RW | | |||||||||||||
scalar · OCTET STRING (SIZE (0..41)) · read-write · current It defines the set-up parameter for OSI stack. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipIpSnmpAgentAddress | 1.3.6.1.4.1.3373.1103.1.20 | IpAddress | RW | 10.250.0.110 | |||||||||||||
scalar · IpAddress · read-write · current Ip address used by SNMP Agent for mark generated TRAP. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipOperationInProgress | 1.3.6.1.4.1.3373.1103.1.21 | Integer32 | RW | 0 | |||||||||||||
scalar · Integer32 · read-write · current A value different from 0 means operation in progress. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipManagerWakeUpAlarm | 1.3.6.1.4.1.3373.1103.1.22 | AlarmStatus | RO | 1 | |||||||||||||
scalar · AlarmStatus · read-only · current This alarm switches on when periodic connection wake-up trap starts. The trap related to this alarm is also sent periodically only to the manager specified by the leaf equipManagerWakeUpIpAddr when equipManagerWakeUpAlarmSeverityCode differs from disable. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipManagerWakeUpAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.1.23 | AlarmSeverityCode | RW | 2 | |||||||||||||
scalar · AlarmSeverityCode · read-write · current Defines the severity associated to the equipManagerWakeUpAlarm and enables/disables the trap generation on status change event. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipManagerWakeUpTimeout | 1.3.6.1.4.1.3373.1103.1.24 | INTEGER (0..1440) | RW | 60 | |||||||||||||
scalar · INTEGER (0..1440) · read-write · current This object defines the time (in minutes) after which the periodic connection wake-up trap is stopped. The maximium value is equivalent to 24 hours. When the timeout elapses the equipManagerWakeUpAlarmSeverityCode is set to disable. A zero means no timeout. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipManagerWakeUpIpAddr | 1.3.6.1.4.1.3373.1103.1.25 | IpAddress | RW | 0.0.0.0 | |||||||||||||
scalar · IpAddress · read-write · current Ip Address of manager wich to send a periodic connection wake-up trap. The periodic trap is sent only if the equipManagerWakeUpAlarmSeverityCode differs from disable. If Ip Address equals 0 no trap will be sent. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipManagerWakeUpGosipAddress | 1.3.6.1.4.1.3373.1103.1.26 | OCTET STRING (SIZE (0..20)) | RW | | |||||||||||||
scalar · OCTET STRING (SIZE (0..20)) · read-write · current Gosip Address of manager wich to send a periodic connection wake-up trap. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipManagerWakeUpTrapVersion | 1.3.6.1.4.1.3373.1103.1.27 | INTEGER | RW | trapV1(1) | |||||||||||||
scalar · INTEGER · read-write · current Trap version supported by Manager to wake-up.
Example values from LibreNMS test devices
| |||||||||||||||||
| SequipManager1IpAddr | 1.3.6.1.4.1.3373.1103.1.28 | IpAddress | RW | 0.0.0.0 | |||||||||||||
scalar · IpAddress · read-write · current First IP address of a SNMP Manager always logged to this equipment. The address 0.0.0.0 mean that manager is not present. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipManager2IpAddr | 1.3.6.1.4.1.3373.1103.1.29 | IpAddress | RW | 0.0.0.0 | |||||||||||||
scalar · IpAddress · read-write · current Second IP address of a SNMP Manager always logged to this equipment. The address 0.0.0.0 mean that manager is not present. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipManager1TrapVersion | 1.3.6.1.4.1.3373.1103.1.30 | INTEGER | RW | trapV1(1) | |||||||||||||
scalar · INTEGER · read-write · current Trap version supported by Manager 1 (related to equipManager1IpAddr).
Example values from LibreNMS test devices
| |||||||||||||||||
| SequipManager2TrapVersion | 1.3.6.1.4.1.3373.1103.1.31 | INTEGER | RW | trapV1(1) | |||||||||||||
scalar · INTEGER · read-write · current Trap version supported by Manager 2 (related to equipManager2IpAddr).
Example values from LibreNMS test devices
| |||||||||||||||||
| SequipDailyPmTimeZone | 1.3.6.1.4.1.3373.1103.1.32 | INTEGER (-12..12) | RW | 0 | |||||||||||||
scalar · INTEGER (-12..12) · read-write · current Reference GMT Time Zone to close the daily P.M. records. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipOperationMngtControl | 1.3.6.1.4.1.3373.1103.1.33 | INTEGER | RW | notActive(0) | |||||||||||||
scalar · INTEGER · read-write · current startOperation means the apply of the 'management parameters set' on the E6165 switch. confirmOperation means the backup of the 'management parameters set'.
Example values from LibreNMS test devices
| |||||||||||||||||
| SequipOperationMngtInProgress | 1.3.6.1.4.1.3373.1103.1.34 | INTEGER | RO | 0 | |||||||||||||
scalar · INTEGER · read-only · current A value different from 0 means Mngt operation in progress. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipLocation | 1.3.6.1.4.1.3373.1103.1.35 | DisplayString (SIZE (0..31)) | RW | | |||||||||||||
scalar · DisplayString (SIZE (0..31)) · read-write · current ASCII string assigned by the operator to identify the location of specific equipment. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipLongitude | 1.3.6.1.4.1.3373.1103.1.36 | INTEGER | RW | 0 | |||||||||||||
scalar · INTEGER · read-write · current Geographic coordinate that specifies the east-west position of the equipment. In order to calculate the latitude in degrees the formula to be applied is Longitude = equipLongitude*180/2^31 This object is used with equipLatitude to locate the equipment on a map. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipLatitude | 1.3.6.1.4.1.3373.1103.1.37 | INTEGER | RW | 0 | |||||||||||||
scalar · INTEGER · read-write · current Geographic coordinate that specifies the north-south position of the equipment. In order to calculate the latitude in degrees the formula to be applied is Latitude = equipLatitude*180/2^31 This object is used with equipLongitude to locate the equipment on a map. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipIpEthVlanId | 1.3.6.1.4.1.3373.1103.1.38 | Integer32 (1..4094) | RW | 1 | |||||||||||||
scalar · Integer32 (1..4094) · read-write · current Ethernet vlan id on top of which management is built Example values from LibreNMS test devices
| |||||||||||||||||
| SequipIpEthDefGateway | 1.3.6.1.4.1.3373.1103.1.39 | IpAddress | RW | 10.250.0.1 | |||||||||||||
scalar · IpAddress · read-write · current Ip address of the default gateway on Ethernet interface. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipIpEthDefGatewayIfIndex | 1.3.6.1.4.1.3373.1103.1.40 | InterfaceIndex (1..999) | RW | 1 | |||||||||||||
scalar · InterfaceIndex (1..999) · read-write · current Ip address of the default gateway on Ethernet interface. Example values from LibreNMS test devices
| |||||||||||||||||
| TequipMngtTable | 1.3.6.1.4.1.3373.1103.1.41 | NA | |||||||||||||||
table · not-accessible · current This is the table that describes the DCN parameters. Two records are created, the first one represents the operational status, the other one represents the administrative status that is applied after reload. The operational record is loaded at the start up and it can not be modified, so the related fields are read only. While the administrative record can be updated. As a restriction, interface type must be configured before the interface identifier. This is to avoid any discrepancy due to the differencies in valid ranges for each interface type. | |||||||||||||||||
| RequipMngtTableEntry | 1.3.6.1.4.1.3373.1103.1.41.1 | NA | |||||||||||||||
| CequipMngtStatus | 1.3.6.1.4.1.3373.1103.1.41.1.1 | INTEGER | RO | operational(1) | |||||||||||||
column · INTEGER · read-only · current The index to select one of two records of table: the operational record and the administrative record.
Example values from LibreNMS test devices
| |||||||||||||||||
| CequipMngtIpAddress | 1.3.6.1.4.1.3373.1103.1.41.1.2 | IpAddress | RW | 10.250.0.110 | |||||||||||||
column · IpAddress · read-write · current The IP address of the equipment. Example values from LibreNMS test devices
| |||||||||||||||||
| CequipMngtIpNetMask | 1.3.6.1.4.1.3373.1103.1.41.1.3 | IpAddress | RW | 255.255.255.0 | |||||||||||||
column · IpAddress · read-write · current The network mask associated with the IP address. Example values from LibreNMS test devices
| |||||||||||||||||
| CequipMngtIpDefGateway | 1.3.6.1.4.1.3373.1103.1.41.1.4 | IpAddress | RW | 10.250.0.1 | |||||||||||||
column · IpAddress · read-write · current The IP address of the default gateway. Example values from LibreNMS test devices
| |||||||||||||||||
| CequipMngtIpDefGatewayIfIndex | 1.3.6.1.4.1.3373.1103.1.41.1.5 | InterfaceIndex (1..999) | RW | 1 | |||||||||||||
column · InterfaceIndex (1..999) · read-write · current The interface selected to reach the default gateway. The special value 1 means that the snmp agent selects the interface whose IP address belongs to the defaul gateway subnet. Example values from LibreNMS test devices
| |||||||||||||||||
| CequipMngtIfType | 1.3.6.1.4.1.3373.1103.1.41.1.6 | INTEGER | RW | vlan(3) | |||||||||||||
column · INTEGER · read-write · current The type of management interface: - value 1 for physical lan interface, - value 2 for virtual loopback interface, - value 3 for management over vlan interface. This object must be configured before the interface identifier (equipMngtIfId), to avoid any discrepancy due to the differencies in valid ranges for each interface type. This object can be modified only in specific equipment and specific software version. Actual accepted values depend on specific equipment and specific software version.
Example values from LibreNMS test devices
| |||||||||||||||||
| CequipMngtIfId | 1.3.6.1.4.1.3373.1103.1.41.1.7 | INTEGER (0..4094) | RW | 1 | |||||||||||||
column · INTEGER (0..4094) · read-write · current The identifier of management interface: - if equipMngtIfType is ethernet: equipMngtIfId is the ifIndex of interface; - if equipMngtIfType is loopback: equipMngtIfId is in the interface name (es: loopback1) - if equipMngtIfType is vlan: equipMngtIfId is the vlan ID. This object can be modified only in specific equipment and specific software version. Example values from LibreNMS test devices
| |||||||||||||||||
| CequipMngtIfPortVlanId | 1.3.6.1.4.1.3373.1103.1.41.1.8 | InterfaceIndex | RW | 1 | |||||||||||||
column · InterfaceIndex · read-write · current The ifIndex corresponding to the port registered to vlan ID; it is valid only when equipMngtIfType is vlan, whose value is in equipMngtIfId. This object can be modified only in specific equipment and specific software version. Example values from LibreNMS test devices
| |||||||||||||||||
| SequipLastRestartType | 1.3.6.1.4.1.3373.1103.1.42 | OCTET STRING (SIZE (0..41)) | RO | ColdBootRequestedbyRescue | |||||||||||||
scalar · OCTET STRING (SIZE (0..41)) · read-only · current Report the last restart-type performed in the system. Example values from LibreNMS test devices
| |||||||||||||||||
Traps / Notifications
- equipConfigChangeStatus
1.3.6.1.4.1.3373.1103.0.114 - equipLOMConnectedConfig
1.3.6.1.4.1.3373.1103.0.110 - equipLOMConnectedMonitor
1.3.6.1.4.1.3373.1103.0.109 - equipLOMDisconnected
1.3.6.1.4.1.3373.1103.0.111 - equipManagerWakeUpNotify
1.3.6.1.4.1.3373.1103.0.123