XCONNECTION-MIB
SAGEMCOM SASThe MIB module describes connection in physical layer of transmission equipements such as pdh/sdh mux and cross connect. This mib assumes that terminaison point are provided by other mibs, such as sdh.mib. xconnection is a particular case of SubNetworkConnection defined in ETS 300 653
snmptranslate -m XCONNECTION-MIB -Tpsnmpwalk -v2c -c <community> -m XCONNECTION-MIB <host> 1.3.6.1.4.1.1038.108Imports
| EQUIPMENT-MIB | SagemBoolean |
|---|---|
| SAGEM-DR-MIB | sagemDr |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Ixconnection | 1.3.6.1.4.1.1038.108 | |||
identity The MIB module describes connection in physical layer of transmission equipements such as pdh/sdh mux and cross connect. This mib assumes that terminaison point are provided by other mibs, such as sdh.mib. xconnection is a particular case of SubNetworkConnection defined in ETS 300 653 | ||||
| Nlink | 1.3.6.1.4.1.1038.108.10 | |||
| SlinkNumber | 1.3.6.1.4.1.1038.108.10.1 | INTEGER (0..2147483647) | RO | |
scalar · INTEGER (0..2147483647) · read-only · current Number of cross connections in equipment. | ||||
| TlinkTable | 1.3.6.1.4.1.1038.108.10.2 | NA | ||
table · not-accessible · current List of link in equipment. For example, a bidirectionnal connection is composed of 2 links. A SNC protected bidirectionnal connection is composed of 3 permanent links . | ||||
| RlinkEntry | 1.3.6.1.4.1.1038.108.10.2.1 | NA | ||
row · not-accessible · current A particular synchronous physical interface of the equipment.
| ||||
| ClinkIndex | 1.3.6.1.4.1.1038.108.10.2.1.1 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current linkIndex = number of the CTP Output = sncIndex | ||||
| ClinkSinkType | 1.3.6.1.4.1.1038.108.10.2.1.2 | CTPType | RO | |
column · CTPType · read-only · current Kind of CTP table from which the connection is issued | ||||
| ClinkSrcType | 1.3.6.1.4.1.1038.108.10.2.1.3 | CTPType | RO | |
column · CTPType · read-only · current Kind of CTP table from which the connection is issued | ||||
| ClinkCTPSink | 1.3.6.1.4.1.1038.108.10.2.1.4 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current The value of this field indicates the Ouput Connection Point which composes the unidirectionnal link.It's an index in considerated TTP table linkCTPSink = linkIndex | ||||
| ClinkCTPSource | 1.3.6.1.4.1.1038.108.10.2.1.5 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current The value of this field indicates the Input Connection Point which composes the unidirectionnal link. It's an index in considerated TTP table | ||||
| ClinkName | 1.3.6.1.4.1.1038.108.10.2.1.6 | DisplayString | RW | |
column · DisplayString · read-write · current A text string which identifies the name of this link. Links names of a bidirectionnal link must have different name. Same direction SNC protected links have an identical name. M1400 UIT-T specifies the field's format | ||||
| ClinkGroupId | 1.3.6.1.4.1.1038.108.10.2.1.7 | INTEGER (0..2147483647) | RW | |
column · INTEGER (0..2147483647) · read-write · current A group identifier is used to group links by community. | ||||
| ClinkDirection | 1.3.6.1.4.1.1038.108.10.2.1.8 | LinkDirection | RO | |
column · LinkDirection · read-only · current Unidirectional or Bidirectionnal connections. | ||||
| ClinkProtectionType | 1.3.6.1.4.1.1038.108.10.2.1.9 | ProtectionType | RW | |
column · ProtectionType · read-write · current The value of this field indicates the kind of wanted link protection. The default value is NONE. if value is changed in Snc(1)then an entry is created in Snc table with the same index. But this table has to be completed (by setting the PIC,...) to obtain a configured protection. if value is changed in None(0)then the associated entry in Snc table is deleted. When the value is set to Snc for a particular entry of LinkTable, other links which are in relation (of direction or protection) with this main link remain setting to None for this field. But all links are set to the USED(1) value in the next field (linkProtectionStatus) | ||||
| ClinkProtectionStatus | 1.3.6.1.4.1.1038.108.10.2.1.10 | ProtectionStatus | RO | |
column · ProtectionStatus · read-only · current The value of this field indicates if the link is used directly or not in a Snc protection. For a non-protected link, this field is mandatory set to None. The field value particulary allow to know the hability of link deletion. | ||||
| ClinkTrafficStatus | 1.3.6.1.4.1.1038.108.10.2.1.11 | TrafficStatus | RO | |
column · TrafficStatus · read-only · current The value of this field indicates where is the traffic. For a non-protected link, this field is mandatory set to working | ||||
| ClinkImplementation | 1.3.6.1.4.1.1038.108.10.2.1.12 | SagemBoolean | RW | |
column · SagemBoolean · read-write · current Actually, this variable is not implemented (always set to TRUE). But it could be used to allow to reserve a connection without physical implementation | ||||
| Nxcon | 1.3.6.1.4.1.1038.108.30 | |||
| SxconNumber | 1.3.6.1.4.1.1038.108.30.1 | INTEGER (0..2147483647) | RW | |
scalar · INTEGER (0..2147483647) · read-write · current Number of connection to process. | ||||
| SxconSinkType | 1.3.6.1.4.1.1038.108.30.2 | CTPType | RW | |
scalar · CTPType · read-write · current Type of CTP | ||||
| SxconSinkIndex | 1.3.6.1.4.1.1038.108.30.3 | INTEGER (0..2147483647) | RW | |
scalar · INTEGER (0..2147483647) · read-write · current Output CTP | ||||
| SxconSrcType | 1.3.6.1.4.1.1038.108.30.4 | CTPType | RW | |
scalar · CTPType · read-write · current Type of CTP | ||||
| SxconSrcIndex | 1.3.6.1.4.1.1038.108.30.5 | INTEGER (0..2147483647) | RW | |
scalar · INTEGER (0..2147483647) · read-write · current Input CTP | ||||
| SxconDirection | 1.3.6.1.4.1.1038.108.30.6 | XconDir | RW | |
scalar · XconDir · read-write · current Bidirectionnal connections are composed of two unidirectional xcon and therefore 2 link entries. | ||||
| SxconName | 1.3.6.1.4.1.1038.108.30.7 | DisplayString | RW | |
scalar · DisplayString · read-write · current A text string which identifies the name of this cross-connection. M1400 UIT-T specifies the field's format like this: NameTownA/NameSuffixA-NameTownB/NameSuffixB NameFunctionSNameSerial * NameTownX field accepts alpha-numeric and space characters. NameTownB is preceded by a '-' character. Maximum length is 12 charracters. Not mandatory fields. * NameSuffixX field accepts alpha-numeric characters. It's preceded by a '/' character. Maximum length is 3 characters. Not mandatory fields. * NameFunction field accepts alpha-numeric characters. It's followed by a 'S' character. Maximum length is 3 characters. Mandatory field. It represents the function code. * NameSerial field accepts 4-figure number. Not mandatory field. It represents the serial number and will be incremented automatically from the base serial number provided. For ADR2500 equipments: Links names of a bidirectionnal link must have different name. Same direction SNC protected links have an identical name. | ||||
| SxconAction | 1.3.6.1.4.1.1038.108.30.8 | ActionType | RW | |
scalar · ActionType · read-write · current Type of action: Unknown(0) or Creation(1) or deletion(2) | ||||
| SxconProceed | 1.3.6.1.4.1.1038.108.30.20 | SagemBoolean | RW | |
scalar · SagemBoolean · read-write · current This entry is use to create (set to `true'). The value of the field remains to `true' until creation is completed or has been aborted. | ||||
| SxconDiagnostic | 1.3.6.1.4.1.1038.108.30.21 | DisplayString | RO | |
scalar · DisplayString · read-only · current A string used to help in case of trouble. | ||||