PROTECTION-MIB
SAGEMCOM SASThis MIB describe protection mechanisms used by SDH equipment
snmptranslate -m PROTECTION-MIB -Tpsnmpwalk -v2c -c <community> -m PROTECTION-MIB <host> 1.3.6.1.4.1.1038.130Imports
| EQUIPMENT-MIB | SagemBoolean, Severity |
|---|---|
| SAGEM-DR-MIB | sagemDr |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Iprotection | 1.3.6.1.4.1.1038.130 | |||
identity This MIB describe protection mechanisms used by SDH equipment | ||||
| Nmsp | 1.3.6.1.4.1.1038.130.10 | |||
| SmspNumber | 1.3.6.1.4.1.1038.130.10.1 | INTEGER (0..2147483647) | RO | |
scalar · INTEGER (0..2147483647) · read-only · current Number of multiplex section protection in equipment. | ||||
| TmspTable | 1.3.6.1.4.1.1038.130.10.2 | NA | ||
table · not-accessible · current List of multiplex section protection in equipment. | ||||
| RmspEntry | 1.3.6.1.4.1.1038.130.10.2.1 | NA | ||
row · not-accessible · current A particular multiplex section protection of the equipment. Each entry is created in using the msTTPTable of the Sdh-Ets MIB.
| ||||
| CmspIndex | 1.3.6.1.4.1.1038.130.10.2.1.1 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current A unique value which identify a particular multiplex section protection. This index is equal to an msTTPIndex(=spiIndex) which gives the interface involved . The value of index is a constant assigned to an entry at equipment design time. It is usualy related to harware. | ||||
| CmspWorkingPointer | 1.3.6.1.4.1.1038.130.10.2.1.2 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current A reference to the object which sends the data flow to this function on working synchronous port interface side. In most equipments, this value cannot be changed and points to the working MST it is hard wired with. | ||||
| CmspProtectionPointer | 1.3.6.1.4.1.1038.130.10.2.1.3 | INTEGER (0..2147483647) | RW | |
column · INTEGER (0..2147483647) · read-write · current A reference to the object which sends the data flow to this function on protection synchronous port interface side. In most equipments, this value cannot be changed and points to the protection MST it is hard wired with. When this variable is setting, the protection is created and activated (if it's possible). The two considerated sections must have the same Stm Level. | ||||
| CmspType | 1.3.6.1.4.1.1038.130.10.2.1.4 | MspType | RW | |
column · MspType · read-write · current Indication of the protection type. | ||||
| CmspDir | 1.3.6.1.4.1.1038.130.10.2.1.5 | MspDirection | RW | |
column · MspDirection · read-write · current Indication of the direction. | ||||
| CmspTraffic | 1.3.6.1.4.1.1038.130.10.2.1.6 | TrafficStatus | RO | |
column · TrafficStatus · read-only · current The value of this field indicates the protection switch position. | ||||
| CmspRevertive | 1.3.6.1.4.1.1038.130.10.2.1.7 | SagemBoolean | RW | |
column · SagemBoolean · read-write · current If the value is true the msp function is allowed to spontaneously switch back to working chanel when it is available. If not, the msp can switch back to working chanel only if protection chanel fails. | ||||
| CmspWtr | 1.3.6.1.4.1.1038.130.10.2.1.8 | INTEGER (0..2147483647) | RW | |
column · INTEGER (0..2147483647) · read-write · current The time (in seconds) the msp function waits before considering a chanel as good after a fail. | ||||
| CmspSfSdPriority | 1.3.6.1.4.1.1038.130.10.2.1.9 | MspPriority | RW | |
column · MspPriority · read-write · current Signal Fail and Signal Degrade can be treated according to two set of priority. The equipement will send SF and SD events according to the value of this field. | ||||
| CmspSfSdHoldOffTime | 1.3.6.1.4.1.1038.130.10.2.1.10 | INTEGER (0..2147483647) | RW | |
column · INTEGER (0..2147483647) · read-write · current The period (in tenth of seconds) during which a sf or a Signal Degrade is ignored by the MSP switch. | ||||
| CmspCommand | 1.3.6.1.4.1.1038.130.10.2.1.11 | MspCommand | RW | |
column · MspCommand · read-write · current Manual or forced commands can be apply to the protection switch. The forced and manual switch can be refused or cleared by equipment if a higher priority APS command is received or if the protection chanel is down. When this field is set to manual or forced, the mspTraffic field becomes read-write, and a set can be issued to specifie on which chanel the command does apply. Commands: LP (Lockout of Protection) LW (Lockout of Working channel) FSW (Forced Switch of a Working channel to protection) FSP (Forced Switch of a Protection channel to working) case 1+1 MSW (Manual Switch of a Working channel to protection) MSp (Manual Switch of a Protection channel to working) case 1+1 EXER (EXERcise) | ||||
| CmspInitiator | 1.3.6.1.4.1.1038.130.10.2.1.12 | MspInitiator | RO | |
column · MspInitiator · read-only · current Indicates the initiator equipment. | ||||
| CmspStatus | 1.3.6.1.4.1.1038.130.10.2.1.13 | MspStatus | RO | |
column · MspStatus · read-only · current Indicates the initiator equipment status : lockoutProtection(15), forcedSwitch(14), highSF(13), lowSF(12), highSD(11), lowSD(10), manualSwitch(8), waitToRestore(6), exercise(4), reverseRequest(2), doNotRevert(1), noRequest(0) | ||||
| CmspMonitor | 1.3.6.1.4.1.1038.130.10.2.1.14 | SagemBoolean | RW | |
column · SagemBoolean · read-write · current When the value of this field is set to false, the failure detection is stopped for this multiplex section protection. | ||||
| CmspFailure | 1.3.6.1.4.1.1038.130.10.2.1.15 | MspFailure | RO | |
column · MspFailure · read-only · current Active failures on multiplex section protection. | ||||
| CmspSeverity | 1.3.6.1.4.1.1038.130.10.2.1.16 | Severity | RO | |
column · Severity · read-only · current A reference to failure severity for multiplex section protection. | ||||
| CmspPam | 1.3.6.1.4.1.1038.130.10.2.1.20 | Severity | RW | |
column · Severity · read-write · current Severity associed with Protection Architecture Mismatch failure for multiplex section protection. | ||||
| CmspScm | 1.3.6.1.4.1.1038.130.10.2.1.21 | Severity | RW | |
column · Severity · read-write · current Severity associed with Selector Control Mismatch failure for multiplex section protection. | ||||
| CmspOtm | 1.3.6.1.4.1.1038.130.10.2.1.22 | Severity | RW | |
column · Severity · read-write · current Severity associed with Operation Type Mismatch failure for multiplex section protection. | ||||
| NmsSPRing | 1.3.6.1.4.1.1038.130.20 | |||
| SmsSPRingNumber | 1.3.6.1.4.1.1038.130.20.1 | INTEGER (0..2147483647) | RO | |
scalar · INTEGER (0..2147483647) · read-only · current Number of multiplex section protection in equipment. | ||||
| TmsSPRingTable | 1.3.6.1.4.1.1038.130.20.6 | NA | ||
table · not-accessible · current List of multiplex section protection in equipment. | ||||
| RmsSPRingEntry | 1.3.6.1.4.1.1038.130.20.6.1 | NA | ||
row · not-accessible · current A particular multiplex section protection of the equipment. Each entry is created in using the msTTPTable of the Sdh-Ets MIB. spiIndex gives the interface involved (line east or west)
| ||||
| CmsSPRingIndex | 1.3.6.1.4.1.1038.130.20.6.1.1 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current A unique value which identify a particular SPRing = West STM index. | ||||
| CmsSPRingWestPointer | 1.3.6.1.4.1.1038.130.20.6.1.2 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current A reference to the object which sends the data flow to this function on synchronous port interface side. In most equipments, this value cannot be changed and points to the West MST it is hard wired with. | ||||
| CmsSPRingEastPointer | 1.3.6.1.4.1.1038.130.20.6.1.3 | INTEGER (0..2147483647) | RW | |
column · INTEGER (0..2147483647) · read-write · current A reference to the object which sends the data flow to this function on synchronous port interface side. In most equipments, this value cannot be changed and points to the East MST it is hard wired with. When this variable is setting, the protection is created and activated (if it's possible). The two considerated sections must have the same Stm Level. | ||||
| CmsSPRingWtr | 1.3.6.1.4.1.1038.130.20.6.1.5 | INTEGER (0..2147483647) | RW | |
column · INTEGER (0..2147483647) · read-write · current The time (in seconds) the spring function waits before considering a chanel as good after a fail. | ||||
| CmsSPRingSfSdHoldOffTime | 1.3.6.1.4.1.1038.130.20.6.1.6 | INTEGER (0..2147483647) | RW | |
column · INTEGER (0..2147483647) · read-write · current The period (in tenth of seconds) during which a sf or a Signal Degrade is ignored by the SPRing switch. | ||||
| CmsSPRingCommandSide | 1.3.6.1.4.1.1038.130.20.6.1.7 | INTEGER (0..2147483647) | RW | |
column · INTEGER (0..2147483647) · read-write · current Side of the command | ||||
| CmsSPRingCommand | 1.3.6.1.4.1.1038.130.20.6.1.8 | MsSPRingCommand | RW | |
column · MsSPRingCommand · read-write · current Manual or forced commands can be apply to the protection switch. | ||||
| CmsSPRingInitiator1 | 1.3.6.1.4.1.1038.130.20.6.1.10 | MsSPRingID | RO | |
column · MsSPRingID · read-only · current A reference(ID) to the equipment that initiate the SWITCH; this is mainly the Master when the equipment is in SWITCH state; in some case like bidirectional SF both equipment of the couple equipment are Master. In PASS state Master and Slave are undeterminated | ||||
| CmsSPRingInitiator2 | 1.3.6.1.4.1.1038.130.20.6.1.11 | MsSPRingID | RO | |
column · MsSPRingID · read-only · current A reference(ID) to the equipment that respond to the SWITCH; this is mainly the Slave when the equipment is in SWITCH state; in some case like bidirectional SF both equipment of the couple equipment are Master. In PASS state Master and Slave are undeterminated | ||||
| CmsSPRingMonitor | 1.3.6.1.4.1.1038.130.20.6.1.12 | SagemBoolean | RW | |
column · SagemBoolean · read-write · current When the value of this field is set to false, the failure detection is stopped for this multiplex section protection. | ||||
| CmsSPRingFailure | 1.3.6.1.4.1.1038.130.20.6.1.13 | MsSPRingFailure | RO | |
column · MsSPRingFailure · read-only · current Active failures on multiplex section protection | ||||
| CmsSPRingSeverity | 1.3.6.1.4.1.1038.130.20.6.1.14 | Severity | RO | |
column · Severity · read-only · current A reference to failure severity for multiplex section protection. | ||||
| CmsSPRingAto | 1.3.6.1.4.1.1038.130.20.6.1.21 | Severity | RW | |
column · Severity · read-write · current Severity associed with APS Time Out failure failure for MS-SPRing. | ||||
| CmsSPRingArv | 1.3.6.1.4.1.1038.130.20.6.1.22 | Severity | RW | |
column · Severity · read-write · current Severity associed with APS Rules Violation failure failure for MS-SPRing. | ||||
| CmsSPRingAun | 1.3.6.1.4.1.1038.130.20.6.1.23 | Severity | RW | |
column · Severity · read-write · current Severity associed with APS Unknown Node failure failure for MS-SPRing. | ||||
| CmsSPRingPtm | 1.3.6.1.4.1.1038.130.20.6.1.24 | Severity | RW | |
column · Severity · read-write · current Severity associed with Potential Traffic Misconnection failure for MS-SPRing. | ||||
| CmsSPRingMms | 1.3.6.1.4.1.1038.130.20.6.1.25 | Severity | RW | |
column · Severity · read-write · current Severity associed with Mutiple Multiplex Section Fail failure for MS-SPRing. | ||||
| CmsSPRingExr | 1.3.6.1.4.1.1038.130.20.6.1.26 | Severity | RW | |
column · Severity · read-write · current Severity associed with EXeRcise failure for MS-SPRing. | ||||
| CmsSPRingSimpleFailure | 1.3.6.1.4.1.1038.130.20.6.1.27 | SagemBoolean | RW | |
column · SagemBoolean · read-write · current Indicate if simple or multi ring failure must be considerated | ||||
| CmsSPRingId | 1.3.6.1.4.1.1038.130.20.6.1.28 | MsSPRingID | RW | |
column · MsSPRingID · read-write · current Ring Identifier of the equipement | ||||
| CmsSPRingNodeState | 1.3.6.1.4.1.1038.130.20.6.1.29 | State | RO | |
| CmsSPRingSwitchingSide | 1.3.6.1.4.1.1038.130.20.6.1.30 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current Switching SideSide | ||||
| CmsSPRingWestTraffic | 1.3.6.1.4.1.1038.130.20.6.1.31 | TrafficStatus | RO | |
column · TrafficStatus · read-only · current The value of this field indicates the protection switch position. | ||||
| CmsSPRingEastTraffic | 1.3.6.1.4.1.1038.130.20.6.1.32 | TrafficStatus | RO | |
column · TrafficStatus · read-only · current The value of this field indicates the protection switch position. | ||||
| CmsSPRingWestStatus | 1.3.6.1.4.1.1038.130.20.6.1.33 | MsSPRingStatus | RO | |
column · MsSPRingStatus · read-only · current Indicates the local status: OFF (19), lockoutProtection (16), forcedSwitch-R(13),sf-R(11),sd-R(8), manualSwitch-R(6), waitToRestore(5),exer-R(3),noRequest(0) | ||||
| CmsSPRingEastStatus | 1.3.6.1.4.1.1038.130.20.6.1.34 | MsSPRingStatus | RO | |
column · MsSPRingStatus · read-only · current Indicates the local status: OFF (19), lockoutProtection (16), forcedSwitch-R(13),sf-R(11),sd-R(8), manualSwitch-R(6), waitToRestore(5),exer-R(3),noRequest(0) | ||||
| TmsSPRingTopoMapTable | 1.3.6.1.4.1.1038.130.20.11 | NA | ||
table · not-accessible · current Topology Map of the ring = West STM index + Val (1<=Val<=16). | ||||
| RmsSPRingTopoMapEntry | 1.3.6.1.4.1.1038.130.20.11.1 | NA | ||
| CmsSPRingTopoMapIndex | 1.3.6.1.4.1.1038.130.20.11.1.1 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current index | ||||
| CmsSPRingTopoMapID | 1.3.6.1.4.1.1038.130.20.11.1.2 | MsSPRingID | RW | |
column · MsSPRingID · read-write · current identifier of the node | ||||
| TmsSPRingMisconMapTable | 1.3.6.1.4.1.1038.130.20.21 | NA | ||
table · not-accessible · current Connectivity (misconnection) Map of the ring. | ||||
| RmsSPRingMisconMapEntry | 1.3.6.1.4.1.1038.130.20.21.1 | NA | ||
row · not-accessible · current A particular entry of the ring connectivity (misconnection) map. All entries are created after setting the msSPRingWestPointer. | ||||
| CmsSPRingMisconMapIndex | 1.3.6.1.4.1.1038.130.20.21.1.1 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current Index = West STM index + Val (1<=Val<=16) ADR2500c : val = 1 to 8 for West and 9 to 16 for East | ||||
| CmsSPRingMisconMapSide | 1.3.6.1.4.1.1038.130.20.21.1.2 | MsSPRingSide | RO | |
column · MsSPRingSide · read-only · current Side (WestPointer/msSPRingEast) of the interface that supports the AU4 | ||||
| CmsSPRingMisconMapIn | 1.3.6.1.4.1.1038.130.20.21.1.3 | MsSPRingID | RW | |
column · MsSPRingID · read-write · current Node of the ring where the Au4 traffic enters the ring | ||||
| CmsSPRingMisconMapOut | 1.3.6.1.4.1.1038.130.20.21.1.4 | MsSPRingID | RW | |
column · MsSPRingID · read-write · current Node of the ring where the Au4 traffic exits the ring | ||||
| CmsSPRingMisconMapTimeSlot | 1.3.6.1.4.1.1038.130.20.21.1.5 | INTEGER (0..2147483647) | RW | |
column · INTEGER (0..2147483647) · read-write · current Time Slot assignment for the AU4 | ||||
| CmsSPRingMisconMapType | 1.3.6.1.4.1.1038.130.20.21.1.6 | MisconMapType | RW | |
column · MisconMapType · read-write · current If the value is equal to terminated, the traffic in the ring is inserted or extracted at this node. If the value is equal to passedThrough the traffic only cross the node | ||||
| CmsSPRingMisconMapLOAccess | 1.3.6.1.4.1.1038.130.20.21.1.7 | SagemBoolean | RW | |
column · SagemBoolean · read-write · current True if the AU4 is accessed at LO layers somewhere in the ring | ||||
| TmsSPRingNUTTable | 1.3.6.1.4.1.1038.130.20.31 | NA | ||
table · not-accessible · current Topology Map of the ring. | ||||
| RmsSPRingNUTEntry | 1.3.6.1.4.1.1038.130.20.31.1 | NA | ||
| CmsSPRingNUTIndex | 1.3.6.1.4.1.1038.130.20.31.1.1 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current AU4 index = West STM index + Val (Val = working timeSlot; 1<=Val<=8) | ||||
| CmsSPRingNUTisNut | 1.3.6.1.4.1.1038.130.20.31.1.2 | SagemBoolean | RW | |
column · SagemBoolean · read-write · current Define if the traffic is used for NUT Traffic | ||||
| Nsncp | 1.3.6.1.4.1.1038.130.30 | |||
| SsncNumber | 1.3.6.1.4.1.1038.130.30.1 | INTEGER (0..2147483647) | RO | |
scalar · INTEGER (0..2147483647) · read-only · current Number of snc in equipment. | ||||
| TsncTable | 1.3.6.1.4.1.1038.130.30.2 | NA | ||
table · not-accessible · current List of snc protection in equipment. | ||||
| RsncEntry | 1.3.6.1.4.1.1038.130.30.2.1 | NA | ||
row · not-accessible · current A particular SNC protection which is created in using the linkTable of the Xconnection MIB.
| ||||
| CsncIndex | 1.3.6.1.4.1.1038.130.30.2.1.1 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current sncIndex = 1000*sncType + sncTTPSink = linkIndex | ||||
| CsncCTPSink | 1.3.6.1.4.1.1038.130.30.2.1.2 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current The value of this field is the index of the Output Connection to which an snc function is applied. | ||||
| CsncLinkType | 1.3.6.1.4.1.1038.130.30.2.1.3 | LinkType | RO | |
column · LinkType · read-only · current Trail level of the connection | ||||
| CsncCTPSourceW | 1.3.6.1.4.1.1038.130.30.2.1.4 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current The value of this field indicates the Working Input Connection Point which composes the protection link of the Output Connection Point (sncIndex). | ||||
| CsncCTPSourceP | 1.3.6.1.4.1.1038.130.30.2.1.5 | INTEGER (0..2147483647) | RW | |
column · INTEGER (0..2147483647) · read-write · current The value of this field indicates the Protected Input Connection Point which composes the protection link of the Output Connection Point (sncIndex). When this variable is setting, the protection is created and activated (if it's possible). | ||||
| CsncTrafficStatus | 1.3.6.1.4.1.1038.130.30.2.1.6 | TrafficStatus | RO | |
column · TrafficStatus · read-only · current This field indicates the Protection unit switch position. | ||||
| CsncWorkingTriggerType | 1.3.6.1.4.1.1038.130.30.2.1.8 | TriggerCriterion | RW | |
column · TriggerCriterion · read-write · current The value of this field is the criterion to trigger a switch for the Working Input Connection Point.SNC/I uses SF criterion for switching: TU-AIS/TU-LOP for VC12/VC3 , AU-AIS/AU-LOP for VC4 and , by extension, ppiLOS and ppiAIS for pdh inputs. SNC/N uses also SD criterion for switching: SD-V5 for VC12, SD-B3 for VC3/VC4. SNC+LAN adds MS-RDI as switching criterion for LAN connection. NONE means that just board extractions and some board failures activate switching. | ||||
| CsncProtectionTriggerType | 1.3.6.1.4.1.1038.130.30.2.1.9 | TriggerCriterion | RW | |
column · TriggerCriterion · read-write · current The value of this field is the criterion to trigger a switch for the Protection Input Connection Point. SNC/I uses SF criterion for switching: TU-AIS/TU-LOP for VC12/VC3 , AU-AIS/AU-LOP for VC4 and , by extension, ppiLOS and ppiAIS for pdh inputs. SNC/N uses also SD criterion for switching: SD-V5 for VC12, SD-B3 for VC3/VC4. SNC+LAN adds MS-RDI as switching criterion for LAN connection. NONE means that just board extractions and some board failures activate switching. | ||||
| CsncRevertive | 1.3.6.1.4.1.1038.130.30.2.1.20 | SagemBoolean | RW | |
column · SagemBoolean · read-write · current If the value is true the Protection unit function is allowed to spontaneously switch back to working chanel when it is available. If not, the snc can switch back to working chanel only if protection chanel fails. | ||||
| CsncWtr | 1.3.6.1.4.1.1038.130.30.2.1.21 | INTEGER (0..2147483647) | RW | |
column · INTEGER (0..2147483647) · read-write · current The time (in seconds) the Protection unit function waits before considering a chanel as good after a fail. | ||||
| CsncStateProcess | 1.3.6.1.4.1.1038.130.30.2.1.22 | SNCStateProcess | RO | |
column · SNCStateProcess · read-only · current The value of this field indicates the state of the snc protection process. | ||||
| CsncHoldOffTime | 1.3.6.1.4.1.1038.130.30.2.1.23 | INTEGER (0..2147483647) | RW | |
column · INTEGER (0..2147483647) · read-write · current The time in tenth of seconds during which a protection trigger criterion is ignored. | ||||
| CsncCommand | 1.3.6.1.4.1.1038.130.30.2.1.24 | SNCCommand | RW | |
column · SNCCommand · read-write · current Manual or forced commands can be apply to the protection unit. The forced and manual switch can be refused or cleared by equipment if a higher priority evenement is received or if the protection chanel is down. | ||||
| Ncardp | 1.3.6.1.4.1.1038.130.40 | |||
| ScardpNumber | 1.3.6.1.4.1.1038.130.40.1 | INTEGER (0..2147483647) | RO | |
scalar · INTEGER (0..2147483647) · read-only · current Number of card protections in equipment. | ||||
| TcardpTable | 1.3.6.1.4.1.1038.130.40.2 | NA | ||
table · not-accessible · current List of card protections in equipment. | ||||
| RcardpEntry | 1.3.6.1.4.1.1038.130.40.2.1 | NA | ||
row · not-accessible · current A particular card protection which is created in using the boardTable of the Shelf MIB.
| ||||
| CcardpIndex | 1.3.6.1.4.1.1038.130.40.2.1.1 | INTEGER (0..2147483647) | RO | |
column · INTEGER (0..2147483647) · read-only · current cardpIndex = boardIndex in the Shelf Mib. This index points to the working board. | ||||
| CcardpBoardFamily | 1.3.6.1.4.1.1038.130.40.2.1.2 | CardpFamily | RO | |
column · CardpFamily · read-only · current This field indicates the family of board concerned by the protection. | ||||
| CcardpReliefIndex | 1.3.6.1.4.1.1038.130.40.2.1.3 | INTEGER (0..2147483647) | RW | |
column · INTEGER (0..2147483647) · read-write · current A reference to the relief card. It must be an existing index in the boardTable of Shelf Mib. The relief card and the protected Card must below to the same familly. When this variable is setting, the protection is created and activated (if it's possible). | ||||
| CcardpTrafficStatus | 1.3.6.1.4.1.1038.130.40.2.1.4 | TrafficStatus | RO | |
column · TrafficStatus · read-only · current Indication of the protection switch position. | ||||
| CcardpCommand | 1.3.6.1.4.1.1038.130.40.2.1.5 | CardpCommand | RW | |
column · CardpCommand · read-write · current Manual commands can be apply to the protection unit. The manual switch can be refused or cleared by equipment if a higher priority evenement is received or if the protection chanel is down. | ||||
| CcardpStatus | 1.3.6.1.4.1.1038.130.40.2.1.6 | CardpStatus | RO | |
column · CardpStatus · read-only · current Indication of the current protection status | ||||