This module defines ruijie fiber module information mibs.
snmptranslate -m RUIJIE-FIBER-MIB -Tpsnmpwalk -v2c -c <community> -m RUIJIE-FIBER-MIB <host> 1.3.6.1.4.1.4881.1.1.10.2.105Imports
| IF-MIB | ifDescr, ifIndex |
|---|---|
| RUIJIE-SMI | ruijieMgmt |
| RUIJIE-TC | IfIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION, TruthValue |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IruijieFiberMIB | 1.3.6.1.4.1.4881.1.1.10.2.105 | ||||||||||||||||||||
identity This module defines ruijie fiber module information mibs. | |||||||||||||||||||||
| NruijieFiberMIBObjects | 1.3.6.1.4.1.4881.1.1.10.2.105.1 | ||||||||||||||||||||
| TruijieFiberTable | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table for getting Fiber Module information | |||||||||||||||||||||
| RruijieFiberEntry | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1 | NA | |||||||||||||||||||
| CruijieFiberPortIndex | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.1 | IfIndex | RO | ||||||||||||||||||
column · IfIndex · read-only · current Port index of the port. | |||||||||||||||||||||
| CruijieFiberPortDescr | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.2 | DisplayString (SIZE (1..32)) | RO | TFGigabitEthernet 0/1 | |||||||||||||||||
column · DisplayString (SIZE (1..32)) · read-only · current Discription of the port. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransceiverType | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.3 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current Transceiver type of the Fiber module insered into the port.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberConnectorType | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.4 | INTEGER | RO | unknownorunspecified(1) | |||||||||||||||||
column · INTEGER · read-only · current Connector type of the Fiber module insered into the port.
If the transceiver type of Fiber module is unknown(1), then this
object contains a zero value.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberWavelength | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.5 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of wavelength of the Fiber module insered into the port.
If the transceiver type of Fiber module is either fiber100CopperSFP(7)
or fiber1000CopperSFP(13) (or fiber10GCopperSFPPlus(14),
or fiber10GCopperXFP(19), or fiber40GCopperQSFPPlus(26), or fiber2500CopperSFP(28), or unknown(1)), then this
object contains a zero value.Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransferDistanceSMF | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.6 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using single mode fiber for. The value is in units of kilometers. A value of zero means that the transceiver does not support single mode fiber. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransferDistance62point5umOM1 | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.7 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using 62.5 micron multimode (200 MHz*Km at 850 nm, 500 MHz*Km at 1310 nm) fiber. The value is in units of meters. A value of zero means that the transceiver does not support 62.5 micron multimode fiber or the Fiber module type is neither SFP/SFP+ nor QSFP+. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransferDistance62point5um | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.8 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using 62.5 micron core multimode (200 MHz*Km at 850 nm, 500 MHz*Km at 1310 nm) fiber. The value is in units of meters. A value of zero means that the transceiver does not support 62.5 micron multimode fiber or the Fiber module type is not XFP. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransferDistance50umOM2 | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.9 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using 50 micron multimode (500 MHz*Km at 850 nm for SFP module or at 850 nm and 1310 nm for QSFP+ module) fiber. The value is in units of meters. A value of zero means that the transceiver does not support 50 micron multimode fiber or the Fiber module type is neither SFP/SFP+ nor QSFP+. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransferDistance50um | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.10 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using 50 micron core multimode (500 MHz*Km at 850 nm and 1310 nm) fiber. The value is in units of meters. A value of zero means that the transceiver does not support 50 micron core multimode fiber or the Fiber module type is not XFP. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransferDistance50umOM3 | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.11 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using 50 micron multimode OM3(2000 MHz*Km) fiber. The value is in units of meters. A value of zero means that the transceiver does not support 50 micron multimode fiber or the Fiber module type is neither SFP/SFP+ nor QSFP+. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransferDistanceEBW50um | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.12 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using 2000 MHz*Km (850nm) extended bandwidth 50 micron core multimode fiber. The value is in units of meters. A value of zero means that the transceiver does not support extended bandwidth 50 micron multimode fiber or the Fiber module type is not XFP. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransferDistanceCopper | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.13 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using copper cables. The value is in units of meters. A value of zero means that the transceiver does not support copper cables or the Fiber module type is neither SFP/SFP+ nor XFP. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransferDistanceCableAssembly | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.14 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of transfer distance of the Fiber module insered into the port. This value specifies the link length of the Cable assembly passive. The value is in units of meters. A value of zero means that the transceiver is not a cable assemblyor or the Fiber module type is not QSFP+. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberDDMSupportStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.15 | TruthValue | RO | 2 | |||||||||||||||||
column · TruthValue · read-only · current This object indicates that whether the Digital Diagnostic Monitors is implemeted. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberSerialNumber | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.16 | DisplayString (SIZE (1..32)) | RO | | |||||||||||||||||
column · DisplayString (SIZE (1..32)) · read-only · current The serial number of the Fiber module insered into the port. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTemp | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.17 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The temperature of the Fiber module insered into the port. The value is in units of degrees Celsius. If the ruijieFiberDDMSupportStatus is false, the temperature value is 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTempStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.18 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the temperature of the Fiber module is in
the normal level. The status warning(3) indicates that the temperature of
the Fiber module exceeds high warning level or is below low warning level.
The status alarm(4) indicates that the temperature of
the Fiber module exceeds high alarm level or is below low alarm level.
If the ruijieFiberDDMSupportStatus is false or the Fiber module type is
neither SFP/SFP+ nor XFP(or not QSFP+), the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberVoltage | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.19 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The voltage of the Fiber module insered into the port. The value is in units of mVolts. If the ruijieFiberDDMSupportStatus is false, the voltage value is 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberVoltageStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.20 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the voltage of the Fiber module is in
the normal level. The status warning(3) indicates that the voltage of
the Fiber module exceeds high warning level or is below low warning level.
The status alarm(4) indicates that the voltage of
the Fiber module exceeds high alarm level or is below low alarm level.
If the ruijieFiberDDMSupportStatus is false or the Fiber module type is
neither SFP/SFP+ nor XFP(or not QSFP+), the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberBias | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.21 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The bias of the Fiber module insered into the port. The value is in units of uA. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the bias value is 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberBiasStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.22 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the bias of the Fiber module is in
the normal level. The status warning(3) indicates that the bias of
the Fiber module exceeds high warning level or is below low warning level.
The status alarm(4) indicates that the bias of
the Fiber module exceeds high alarm level or is below low alarm level.
If the ruijieFiberDDMSupportStatus is false or the Fiber module type is
neither SFP/SFP+ nor XFP, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel1Bias | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.23 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The bias in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of uA. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the bias value in Channel 1 is 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel1BiasStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.24 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the bias in the Channel 1 of QSFP+ is in the normal level. The status warning(3) indicates that the bias in the Channel 1 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the bias in the Channel 1 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel2Bias | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.25 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The bias in Channel 2 of the QSFP+ Fiber module insered into the port. The value is in units of uA. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the bias value in Channel 2 is 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel2BiasStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.26 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the bias in the Channel 2 of QSFP+ is in the normal level. The status warning(3) indicates that the bias in the Channel 2 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the bias in the Channel 2 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel3Bias | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.27 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The bias in Channel 3 of the QSFP+ Fiber module insered into the port. The value is in units of uA. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the bias value in Channel 3 is 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel3BiasStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.28 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the bias in the Channel 3 of QSFP+ is in the normal level. The status warning(3) indicates that the bias in the Channel 3 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the bias in the Channel 3 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel4Bias | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.29 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The bias in Channel 4 of the QSFP+ Fiber module insered into the port. The value is in units of uA. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the bias value in Channel 4 is 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel4BiasStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.30 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the bias in the Channel 4 of QSFP+ is in the normal level. The status warning(3) indicates that the bias in the Channel 4 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the bias in the Channel 4 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberRXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.31 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Rx power of the Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the integer part of Rx power value is -100(means that the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberRXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.32 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Rx power of the Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the decimal part of Rx power value is -100(means that the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberRXpowertype | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.33 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The value indicates whether the received power measurement represents average input optical power(2) or oma(3). If the ruijieFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP (or not QSFP+), the value is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberRXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.34 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Rx power of the Fiber module is in
the normal level. The status warning(3) indicates that the Rx power of
the Fiber module exceeds high warning level or is below low warning level.
The status alarm(4) indicates that the Rx power of
the Fiber module exceeds high alarm level or is below low alarm level.
If the ruijieFiberDDMSupportStatus is false or the Fiber module type is
neither SFP/SFP+ nor XFP, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel1RXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.35 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Rx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Rx power value in Channel 1 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel1RXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.36 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Rx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the decimal part of Rx power value in Channel 1 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel1RXpowertype | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.37 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The value indicates whether the received power measurement represents average input optical power(2) or oma(3) in Channel 1 of QSFP+. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the value is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel1RXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.38 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Rx power in the Channel 1 of QSFP+ is in the normal level. The status warning(3) indicates that the Rx power in the Channel 1 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Rx power in the Channel 1 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel2RXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.39 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Rx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Rx power value in Channel 1 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel2RXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.40 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Rx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the decimal part of Rx power value in Channel 2 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel2RXpowertype | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.41 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The value indicates whether the received power measurement represents average input optical power(2) or oma(3) in Channel 2 of QSFP+. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the value is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel2RXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.42 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Rx power in the Channel 2 of QSFP+ is in the normal level. The status warning(3) indicates that the Rx power in the Channel 2 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Rx power in the Channel 2 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel3RXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.43 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Rx power in Channel 3 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Rx power value in Channel 3 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel3RXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.44 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Rx power in Channel 3 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the decimal part of Rx power value in Channel 3 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel3RXpowertype | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.45 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The value indicates whether the received power measurement represents average input optical power(2) or oma(3) in Channel 3 of QSFP+. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the value is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel3RXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.46 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Rx power in the Channel 3 of QSFP+ is in the normal level. The status warning(3) indicates that the Rx power in the Channel 3 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Rx power in the Channel 3 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel4RXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.47 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Rx power in Channel 4 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Rx power value in Channel 4 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel4RXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.48 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Rx power in Channel 4 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the decimal part of Rx power value in Channel 4 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel4RXpowertype | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.49 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The value indicates whether the received power measurement represents average input optical power(2) or oma(3) in Channel 4 of QSFP+. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the value is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel4RXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.50 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Rx power in the Channel 4 of QSFP+ is in the normal level. The status warning(3) indicates that the Rx power in the Channel 4 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Rx power in the Channel 4 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.51 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Tx power of the Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the integer part of Tx power value is -100(means that the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.52 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Tx power of the Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the decimal part of Tx power value is -100(means that the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.53 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Tx power of the Fiber module is in
the normal level. The status warning(3) indicates that the Tx power of
the Fiber module exceeds high warning level or is below low warning level.
The status alarm(4) indicates that the Tx power of
the Fiber module exceeds high alarm level or is below low alarm level.
If the ruijieFiberDDMSupportStatus is false or the Fiber module type is
neither SFP/SFP+ nor XFP, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel1TXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.54 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Tx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Tx power value in Channel 1 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel1TXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.55 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Tx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the decimal part of Tx power value in Channel 1 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel1TXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.56 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Tx power in the Channel 1 of QSFP+ is in the normal level. The status warning(3) indicates that the Tx power in the Channel 1 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Tx power in the Channel 1 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel2TXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.57 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Tx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Tx power value in Channel 1 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel2TXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.58 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Tx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the decimal part of Tx power value in Channel 2 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel2TXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.59 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Tx power in the Channel 2 of QSFP+ is in the normal level. The status warning(3) indicates that the Tx power in the Channel 2 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Tx power in the Channel 2 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel3TXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.60 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Tx power in Channel 3 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Tx power value in Channel 3 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel3TXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.61 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Tx power in Channel 3 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the decimal part of Tx power value in Channel 3 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel3TXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.62 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Tx power in the Channel 3 of QSFP+ is in the normal level. The status warning(3) indicates that the Tx power in the Channel 3 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Tx power in the Channel 3 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel4TXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.63 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Tx power in Channel 4 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the integer part of Tx power value in Channel 4 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel4TXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.64 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Tx power in Channel 4 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the decimal part of Tx power value in Channel 4 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel4TXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.65 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Tx power in the Channel 4 of QSFP+ is in the normal level. The status warning(3) indicates that the Tx power in the Channel 4 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Tx power in the Channel 4 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP+, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberRXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.66 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel1RXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.67 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel2RXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.68 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel3RXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.69 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel4RXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.70 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.71 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel1TXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.72 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel2TXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.73 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel3TXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.74 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel4TXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.75 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberRXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.76 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Rx power of the Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel1RXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.77 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Rx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel2RXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.78 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Rx power in Channel 2 of the QSFP+ Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel3RXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.79 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Rx power in Channel 3 of the QSFP+ Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel4RXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.80 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Rx power in Channel 4 of the QSFP+ Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.81 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Tx power of the Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel1TXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.82 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Tx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel2TXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.83 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Tx power in Channel 2 of the QSFP+ Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel3TXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.84 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Tx power in Channel 3 of the QSFP+ Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel4TXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.85 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Tx power in Channel 4 of the QSFP+ Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberWavelengthExact | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.86 | DisplayString (SIZE (1..32)) | RO | | |||||||||||||||||
column · DisplayString (SIZE (1..32)) · read-only · current The value of wavelength of the Fiber module insered into the port.
If the transceiver type of Fiber module is either fiber100CopperSFP(7)
or fiber1000CopperSFP(13) (or fiber10GCopperSFPPlus(14),
or fiber10GCopperXFP(19), or fiber40GCopperQSFPPlus(26), or fiber2500CopperSFP(28), or unknown(1)), then this
object contains a NA value.Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransferDistance50umOM4 | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.87 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using 50 micron multimode OM4(4700 MHz*Km) fiber. The value is in units of meters. A value of zero means that the transceiver does not support 50 micron multimode fiber or the Fiber module type is neither SFP/SFP+ nor QSFP+. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransferDistanceSMFExt | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.88 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using single mode fiber for. The value is in units of meters. A value of zero means that the transceiver does not support single mode fiber. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberBandWidth | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.89 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of transfer maximum available bandwidth of the Fiber module insered into the port. The value is in units of Mbit/s. A value of zero means that the transceiver does not insert or unknown type. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberFormFactor | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.90 | INTEGER | RO | unknown(0) | |||||||||||||||||
column · INTEGER · read-only · current Indicates the form factor of the Fiber module insered into the port.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberRXpowerLowWarnThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.91 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Rx power low warning threshold of the Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberRXpowerHighWarnThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.92 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Rx power high warning threshold of the Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberRXpowerLowAlarmThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.93 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Rx power low alarm threshold of the Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberRXpowerHighAlarmThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.94 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Rx power high alarm threshold of the Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTXpowerLowWarnThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.95 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Tx power low warning threshold of the Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTXpowerHighWarnThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.96 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Tx power high warning threshold of the Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTXpowerLowAlarmThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.97 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Tx power low alarm threshold of the Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTXpowerHighAlarmThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.98 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Tx power high alarm threshold of the Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel5Bias | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.99 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The bias in Channel 5 of the QSFP CMIS Fiber module insered into the port. The value is in units of uA. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the bias value in Channel 5 is 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel5BiasStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.100 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the bias in the Channel 5 of QSFP CMIS is in the normal level. The status warning(3) indicates that the bias in the Channel 5 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the bias in the Channel 5 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel6Bias | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.101 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The bias in Channel 6 of the QSFP CMIS Fiber module insered into the port. The value is in units of uA. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the bias value in Channel 6 is 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel6BiasStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.102 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the bias in the Channel 6 of QSFP CMIS is in the normal level. The status warning(3) indicates that the bias in the Channel 6 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the bias in the Channel 6 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel7Bias | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.103 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The bias in Channel 7 of the QSFP CMIS Fiber module insered into the port. The value is in units of uA. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the bias value in Channel 7 is 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel7BiasStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.104 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the bias in the Channel 7 of QSFP CMIS is in the normal level. The status warning(3) indicates that the bias in the Channel 7 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the bias in the Channel 7 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel8Bias | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.105 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The bias in Channel 8 of the QSFP CMIS Fiber module insered into the port. The value is in units of uA. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the bias value in Channel 8 is 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel8BiasStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.106 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the bias in the Channel 8 of QSFP CMIS is in the normal level. The status warning(3) indicates that the bias in the Channel 8 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the bias in the Channel 8 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel5RXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.107 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Rx power in Channel 5 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the integer part of Rx power value in Channel 5 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel5RXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.108 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Rx power in Channel 5 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the decimal part of Rx power value in Channel 5 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel5RXpowertype | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.109 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The value indicates whether the received power measurement represents average input optical power(2) or oma(3) in Channel 5 of QSFP CMIS. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the value is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel5RXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.110 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Rx power in the Channel 5 of QSFP CMIS is in the normal level. The status warning(3) indicates that the Rx power in the Channel 5 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Rx power in the Channel 5 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel6RXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.111 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Rx power in Channel 6 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the integer part of Rx power value in Channel 6 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel6RXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.112 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Rx power in Channel 6 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the decimal part of Rx power value in Channel 6 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel6RXpowertype | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.113 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The value indicates whether the received power measurement represents average input optical power(2) or oma(3) in Channel 6 of QSFP CMIS. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the value is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel6RXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.114 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Rx power in the Channel 6 of QSFP CMIS is in the normal level. The status warning(3) indicates that the Rx power in the Channel 6 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Rx power in the Channel 6 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel7RXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.115 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Rx power in Channel 7 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the integer part of Rx power value in Channel 7 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel7RXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.116 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Rx power in Channel 7 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the decimal part of Rx power value in Channel 7 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel7RXpowertype | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.117 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The value indicates whether the received power measurement represents average input optical power(2) or oma(3) in Channel 7 of QSFP CMIS. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the value is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel7RXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.118 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Rx power in the Channel 7 of QSFP CMIS is in the normal level. The status warning(3) indicates that the Rx power in the Channel 7 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Rx power in the Channel 7 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel8RXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.119 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Rx power in Channel 8 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the integer part of Rx power value in Channel 8 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel8RXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.120 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Rx power in Channel 8 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the decimal part of Rx power value in Channel 8 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel8RXpowertype | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.121 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The value indicates whether the received power measurement represents average input optical power(2) or oma(3) in Channel 8 of QSFP CMIS. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the value is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel8RXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.122 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Rx power in the Channel 8 of QSFP CMIS is in the normal level. The status warning(3) indicates that the Rx power in the Channel 8 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Rx power in the Channel 8 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel5TXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.123 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Tx power in Channel 5 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the integer part of Tx power value in Channel 5 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel5TXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.124 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Tx power in Channel 5 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the decimal part of Tx power value in Channel 5 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel5TXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.125 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Tx power in the Channel 5 of QSFP CMIS is in the normal level. The status warning(3) indicates that the Tx power in the Channel 5 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Tx power in the Channel 5 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel6TXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.126 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Tx power in Channel 6 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the integer part of Tx power value in Channel 6 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel6TXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.127 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Tx power in Channel 6 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the decimal part of Tx power value in Channel 6 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel6TXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.128 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Tx power in the Channel 6 of QSFP CMIS is in the normal level. The status warning(3) indicates that the Tx power in the Channel 6 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Tx power in the Channel 6 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel7TXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.129 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Tx power in Channel 7 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the integer part of Tx power value in Channel 7 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel7TXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.130 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Tx power in Channel 7 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the decimal part of Tx power value in Channel 7 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel7TXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.131 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Tx power in the Channel 7 of QSFP CMIS is in the normal level. The status warning(3) indicates that the Tx power in the Channel 7 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Tx power in the Channel 7 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel8TXpowerIntegerpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.132 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The integer part of Tx power in Channel 8 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the integer part of Tx power value in Channel 8 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel8TXpowerDecimalpart | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.133 | INTEGER | RO | -100 | |||||||||||||||||
column · INTEGER · read-only · current The decimal part of Tx power in Channel 8 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the decimal part of Tx power value in Channel 8 is -100(means the value is invalid). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel8TXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.134 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Tx power in the Channel 8 of QSFP CMIS is in the normal level. The status warning(3) indicates that the Tx power in the Channel 8 exceeds high warning level or is below low warning level. The status alarm(4) indicates that the Tx power in the Channel 8 exceeds high alarm level or is below low alarm level. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is not QSFP CMIS, the status is unknown(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel5RXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.135 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel6RXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.136 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel7RXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.137 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel8RXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.138 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel5TXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.139 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel6TXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.140 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel7TXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.141 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel8TXpowerSign | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.142 | INTEGER | RO | 1 | |||||||||||||||||
column · INTEGER · read-only · current The sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel5RXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.143 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Rx power in Channel 5 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel6RXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.144 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Rx power in Channel 6 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel7RXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.145 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Rx power in Channel 7 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel8RXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.146 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Rx power in Channel 8 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel5TXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.147 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Tx power in Channel 5 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel6TXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.148 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Tx power in Channel 6 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel7TXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.149 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Tx power in Channel 7 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberChannel8TXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.150 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The Tx power in Channel 8 of the QSFP CMIS Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransferDistance50umOM5 | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.151 | INTEGER | RO | 0 | |||||||||||||||||
column · INTEGER · read-only · current The value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using 50 micron multimode OM5(4700 MHz*Km at 850nm, 2470 MHz*km at 953nm) fiber. The value is in units of meters. A value of zero means that the transceiver does not support 50 micron multimode fiber or the Fiber module type is neither SFP/SFP+ nor QSFP+. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberMode | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.152 | INTEGER | RO | unknown(0) | |||||||||||||||||
column · INTEGER · read-only · current This object indicates the fiber type.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTempLowWarnThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.153 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The temperature low warning threshold of the Fiber module insered into the port. The value is in units of degrees Celsius. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTempHighWarnThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.154 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The temperature high warning threshold of the Fiber module insered into the port. The value is in units of degrees Celsius. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTempLowAlarmThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.155 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The temperature low alarm threshold of the Fiber module insered into the port. The value is in units of degrees Celsius. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTempHighAlarmThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.156 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The temperature high alarm threshold of the Fiber module insered into the port. The value is in units of degrees Celsius. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberVoltageLowWarnThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.157 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The voltage low warning threshold of the Fiber module insered into the port. The value is in units of mVolts. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberVoltageHighWarnThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.158 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The voltage high warning threshold of the Fiber module insered into the port. The value is in units of mVolts. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberVoltageLowAlarmThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.159 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The voltage low alarm threshold of the Fiber module insered into the port. The value is in units of mVolts. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberVoltageHighAlarmThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.160 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The voltage high alarm threshold of the Fiber module insered into the port. The value is in units of mVolts. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberBiasLowWarnThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.161 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The bias low warning threshold of the Fiber module insered into the port. The value is in units of uA. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberBiasHighWarnThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.162 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The bias high warning threshold of the Fiber module insered into the port. The value is in units of uA. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberBiasLowAlarmThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.163 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The bias low alarm threshold of the Fiber module insered into the port. The value is in units of uA. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberBiasHighAlarmThreshold | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.164 | INTEGER | RO | -10000 | |||||||||||||||||
column · INTEGER · read-only · current The bias high alarm threshold of the Fiber module insered into the port. The value is in units of uA. The value of -10000 means the value is invalid. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CruijieFiberTransceiverTypeStr | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.165 | DisplayString (SIZE (1..64)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..64)) · read-only · current Transceiver type of the Fiber module inserted into the port. | |||||||||||||||||||||
| CruijieFiberConnectorTypeStr | 1.3.6.1.4.1.4881.1.1.10.2.105.1.1.1.166 | DisplayString (SIZE (1..64)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..64)) · read-only · current Connector type of the Fiber module inserted into the port. | |||||||||||||||||||||
| TruijieFiberVendorTable | 1.3.6.1.4.1.4881.1.1.10.2.105.1.2 | NA | |||||||||||||||||||
table · not-accessible · current A table of Vendor info entries. | |||||||||||||||||||||
| RruijieFiberVendorEntry | 1.3.6.1.4.1.4881.1.1.10.2.105.1.2.1 | NA | |||||||||||||||||||
| CruijieFiberVendorPortIndex | 1.3.6.1.4.1.4881.1.1.10.2.105.1.2.1.1 | IfIndex | RO | ||||||||||||||||||
column · IfIndex · read-only · current The port index of Vendor info . | |||||||||||||||||||||
| CruijieFiberVendorName | 1.3.6.1.4.1.4881.1.1.10.2.105.1.2.1.2 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The description of vendor name. | |||||||||||||||||||||
| CruijieFiberVendorOUI | 1.3.6.1.4.1.4881.1.1.10.2.105.1.2.1.3 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The description of vendor oui. | |||||||||||||||||||||
| CruijieFiberVendorPartNumber | 1.3.6.1.4.1.4881.1.1.10.2.105.1.2.1.4 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The description of vendor part number. | |||||||||||||||||||||
| CruijieFiberVendorRev | 1.3.6.1.4.1.4881.1.1.10.2.105.1.2.1.5 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The description of vendor revision. | |||||||||||||||||||||
| CruijieFiberManufacturingDate | 1.3.6.1.4.1.4881.1.1.10.2.105.1.2.1.6 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The description of vendor's manufacturing date. | |||||||||||||||||||||
| CruijieFiberEncoding | 1.3.6.1.4.1.4881.1.1.10.2.105.1.2.1.7 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The description of vendor's encoding type. | |||||||||||||||||||||
| TruijieFiberOMCTable | 1.3.6.1.4.1.4881.1.1.10.2.105.1.3 | NA | |||||||||||||||||||
table · not-accessible · current A table of OMC fiber info entries. | |||||||||||||||||||||
| RruijieFiberOMCEntry | 1.3.6.1.4.1.4881.1.1.10.2.105.1.3.1 | NA | |||||||||||||||||||
| CruijieFiberOMCPortIndex | 1.3.6.1.4.1.4881.1.1.10.2.105.1.3.1.1 | IfIndex | RO | ||||||||||||||||||
column · IfIndex · read-only · current Port index of the port. | |||||||||||||||||||||
| CruijieFiberOMCRxpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.3.1.2 | DisplayString (SIZE (0..255)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-only · current The Rx power of the Fiber module insered into the port. Use a comma to separate multiple optical power values for multiple channels, fill in key-value pairs, connect the key and value with an equal sign, the key is the channel name, and the value is the optical power. The unit of the optical power value is dbw. | |||||||||||||||||||||
| CruijieFiberOMCTxpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.3.1.3 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The Tx power of the Fiber module insered into the port. Use a comma to separate multiple optical power values for multiple channels, fill in key-value pairs, connect the key and value with an equal sign, the key is the channel name, and the value is the optical power. The unit of the optical power value is dbw. | |||||||||||||||||||||
| CruijieFiberOMCWavelength | 1.3.6.1.4.1.4881.1.1.10.2.105.1.3.1.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-only · current The value of wavelength of the Fiber module insered into the port. The unit is nm. If it is a single wavelength, report a single value, for example: 1310. If it is a wavelength range, report the wavelength range, for example: 1310-1312. The reported string does not include the unit. | |||||||||||||||||||||
| CruijieFiberOMCTranslength | 1.3.6.1.4.1.4881.1.1.10.2.105.1.3.1.5 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The value of transfer distance of the Fiber module insered into the port. The unit is km. If it is a single distance, report a single value, for example: 20 If there are multiple distances in fiber mode, report multiple sets of data separated by commas. The format of each group of data is a key-value pair, the key and value are connected with =, the key is the fiber grade, and the value is the corresponding distance, such as 'OM1=20, OM2=30' | |||||||||||||||||||||
| CruijieFiberOMCPortType | 1.3.6.1.4.1.4881.1.1.10.2.105.1.3.1.6 | DisplayString (SIZE (0..255)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-only · current Port type of the Fiber module insered into the port. | |||||||||||||||||||||
| TruijieFiberChannelTable | 1.3.6.1.4.1.4881.1.1.10.2.105.1.4 | NA | |||||||||||||||||||
table · not-accessible · current A table of fiber channel information entries. | |||||||||||||||||||||
| RruijieFiberChannelEntry | 1.3.6.1.4.1.4881.1.1.10.2.105.1.4.1 | NA | |||||||||||||||||||
row · not-accessible · current Entry contains fiber channel information. | |||||||||||||||||||||
| CruijieFiberChannelPortIndex | 1.3.6.1.4.1.4881.1.1.10.2.105.1.4.1.1 | IfIndex | RO | ||||||||||||||||||
column · IfIndex · read-only · current The port index of fiber channel information. | |||||||||||||||||||||
| CruijieFiberChannelIndex | 1.3.6.1.4.1.4881.1.1.10.2.105.1.4.1.2 | INTEGER (1..32) | RO | ||||||||||||||||||
column · INTEGER (1..32) · read-only · current The channel index of fiber channel. | |||||||||||||||||||||
| CruijieFiberChannelBias | 1.3.6.1.4.1.4881.1.1.10.2.105.1.4.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The bias of the Fiber module insered into the port. The value is in units of uA. If the ruijieFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP, the bias value is 0. | |||||||||||||||||||||
| CruijieFiberChannelBiasStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.4.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the bias of the Fiber module is in
the normal level. The status warning(3) indicates that the bias of
the Fiber module exceeds high warning level or is below low warning level.
The status alarm(4) indicates that the bias of
the Fiber module exceeds high alarm level or is below low alarm level.
If the ruijieFiberDDMSupportStatus is false or the Fiber module type is
neither SFP/SFP+ nor XFP, the status is unknown(1). | |||||||||||||||||||||
| CruijieFiberChannelRXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.4.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The Rx power of the Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. | |||||||||||||||||||||
| CruijieFiberChannelRXpowertype | 1.3.6.1.4.1.4881.1.1.10.2.105.1.4.1.6 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The value indicates whether the received power measurement represents average input optical power(2) or oma(3). If the ruijieFiberDDMSupportStatus is false or the Fiber module type is neither SFP/SFP+ nor XFP (or not QSFP+), the value is unknown(1). | |||||||||||||||||||||
| CruijieFiberChannelRXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.4.1.7 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Rx power of the Fiber module is in
the normal level. The status warning(3) indicates that the Rx power of
the Fiber module exceeds high warning level or is below low warning level.
The status alarm(4) indicates that the Rx power of
the Fiber module exceeds high alarm level or is below low alarm level.
If the ruijieFiberDDMSupportStatus is false or the Fiber module type is
neither SFP/SFP+ nor XFP, the status is unknown(1). | |||||||||||||||||||||
| CruijieFiberChannelTXpower | 1.3.6.1.4.1.4881.1.1.10.2.105.1.4.1.8 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The Tx power of the Fiber module insered into the port. The value is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. | |||||||||||||||||||||
| CruijieFiberChannelTXpowerStatus | 1.3.6.1.4.1.4881.1.1.10.2.105.1.4.1.9 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status ok(2) indicates that the Tx power of the Fiber module is in
the normal level. The status warning(3) indicates that the Tx power of
the Fiber module exceeds high warning level or is below low warning level.
The status alarm(4) indicates that the Tx power of
the Fiber module exceeds high alarm level or is below low alarm level.
If the ruijieFiberDDMSupportStatus is false or the Fiber module type is
neither SFP/SFP+ nor XFP, the status is unknown(1). | |||||||||||||||||||||
| CruijieFiberChannelAPR | 1.3.6.1.4.1.4881.1.1.10.2.105.1.4.1.10 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The transceiver automatic power reduction state. The status on(2) indicates that the transceiver is in automatic power reduction state. The status off(1) indicates that the transceiver is not in automatic power reduction state.
| |||||||||||||||||||||
| NruijieFiberAntifakeMIBTraps | 1.3.6.1.4.1.4881.1.1.10.2.105.2 | ||||||||||||||||||||
| SruijieFiberAntifakeIntfNameDesc | 1.3.6.1.4.1.4881.1.1.10.2.105.2.1 | DisplayString (SIZE (0..255)) | AN | ||||||||||||||||||
scalar · DisplayString (SIZE (0..255)) · accessible-for-notify · current The description of the interface. | |||||||||||||||||||||
| SruijieFiberAntifakeSerialNumberDesc | 1.3.6.1.4.1.4881.1.1.10.2.105.2.2 | DisplayString (SIZE (0..255)) | AN | ||||||||||||||||||
scalar · DisplayString (SIZE (0..255)) · accessible-for-notify · current The description of the serial number of the fiber module. | |||||||||||||||||||||
| !ruijieFiberAntifakeTrap | 1.3.6.1.4.1.4881.1.1.10.2.105.2.3 | ||||||||||||||||||||
notification · current When detect the fiber module is not original ruijie fiber module, then this trap will be sent. | |||||||||||||||||||||
| NruijieFiberMIBConformance | 1.3.6.1.4.1.4881.1.1.10.2.105.3 | ||||||||||||||||||||
| NruijieFiberMIBCompliances | 1.3.6.1.4.1.4881.1.1.10.2.105.3.1 | ||||||||||||||||||||
| MruijieFiberMIBConpliance | 1.3.6.1.4.1.4881.1.1.10.2.105.3.1.1 | ||||||||||||||||||||
compliance · current The compliance statement for entities which implement the Ruijie Fiber MIB | |||||||||||||||||||||
| NruijieFiberMIBGroups | 1.3.6.1.4.1.4881.1.1.10.2.105.3.2 | ||||||||||||||||||||
| GruijieFiberMIBGroup | 1.3.6.1.4.1.4881.1.1.10.2.105.3.2.1 | ||||||||||||||||||||
group · current A collection of objects providing Fiber managment.
| |||||||||||||||||||||
| GruijieFiberAntifakeIntfNameDescGroup | 1.3.6.1.4.1.4881.1.1.10.2.105.3.2.2 | ||||||||||||||||||||
group · current Objects that providing a literal description of the interface. | |||||||||||||||||||||
| GruijieFiberAntifakeSerialNumberDescGroup | 1.3.6.1.4.1.4881.1.1.10.2.105.3.2.3 | ||||||||||||||||||||
group · current Objects that providing a literal description of the fiber module serial number. | |||||||||||||||||||||
| NruijieFiberEventMIBTraps | 1.3.6.1.4.1.4881.1.1.10.2.105.4 | ||||||||||||||||||||
| SruijieFiberEventReason | 1.3.6.1.4.1.4881.1.1.10.2.105.4.1 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current The reason of the fiber invalid event.
| |||||||||||||||||||||
| SruijieFiberEventDesc | 1.3.6.1.4.1.4881.1.1.10.2.105.4.2 | DisplayString (SIZE (0..255)) | AN | ||||||||||||||||||
scalar · DisplayString (SIZE (0..255)) · accessible-for-notify · current The description of the fiber invalid event. | |||||||||||||||||||||
| !ruijieFiberRemoveEventTrap | 1.3.6.1.4.1.4881.1.1.10.2.105.4.3 | ||||||||||||||||||||
| !ruijieFiberInsertEventTrap | 1.3.6.1.4.1.4881.1.1.10.2.105.4.4 | ||||||||||||||||||||
| !ruijieFiberInvalidTrap | 1.3.6.1.4.1.4881.1.1.10.2.105.4.5 | ||||||||||||||||||||
notification · current Detect the fiber invalid event. | |||||||||||||||||||||
| !ruijieFiberInvalidResumeTrap | 1.3.6.1.4.1.4881.1.1.10.2.105.4.6 | ||||||||||||||||||||
notification · current The fiber resume from invalid event. | |||||||||||||||||||||
| SruijieFiberAlarmValue | 1.3.6.1.4.1.4881.1.1.10.2.105.4.7 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current The realtime value of the fiber invalid event. The value of power is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. | |||||||||||||||||||||
| SruijieFiberAlarmThresholdValue | 1.3.6.1.4.1.4881.1.1.10.2.105.4.8 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current The threshold value of the fiber invalid event. The value of power is in units of dbm, which needs to be divided by 100. The value of -10000 means the value is invalid. | |||||||||||||||||||||
| !ruijieFiberSpeedMismatch | 1.3.6.1.4.1.4881.1.1.10.2.105.4.9 | ||||||||||||||||||||
| !ruijieFiberUnCertified | 1.3.6.1.4.1.4881.1.1.10.2.105.4.10 | ||||||||||||||||||||
| !ruijieFiberUnCertifiedClear | 1.3.6.1.4.1.4881.1.1.10.2.105.4.11 | ||||||||||||||||||||
Traps / Notifications
- ruijieFiberAntifakeTrap
1.3.6.1.4.1.4881.1.1.10.2.105.2.3 - ruijieFiberInsertEventTrap
1.3.6.1.4.1.4881.1.1.10.2.105.4.4 - ruijieFiberInvalidResumeTrap
1.3.6.1.4.1.4881.1.1.10.2.105.4.6 - ruijieFiberInvalidTrap
1.3.6.1.4.1.4881.1.1.10.2.105.4.5 - ruijieFiberRemoveEventTrap
1.3.6.1.4.1.4881.1.1.10.2.105.4.3 - ruijieFiberSpeedMismatch
1.3.6.1.4.1.4881.1.1.10.2.105.4.9 - ruijieFiberUnCertified
1.3.6.1.4.1.4881.1.1.10.2.105.4.10 - ruijieFiberUnCertifiedClear
1.3.6.1.4.1.4881.1.1.10.2.105.4.11