RAISECOM-OPTICAL-TRANSCEIVER-MIB
Beijing Raisecom Scientific & Technology Development Co., Ltd.This MIB module defines objects to monitor optical characteristics on the optical interfaces in a network element.
snmptranslate -m RAISECOM-OPTICAL-TRANSCEIVER-MIB -Tpsnmpwalk -v2c -c <community> -m RAISECOM-OPTICAL-TRANSCEIVER-MIB <host> 1.3.6.1.4.1.8886.1.18Imports
| IF-MIB | ifIndex |
|---|---|
| RAISECOM-BASE-MIB | raisecomAgent |
| RAISECOM-COMMON-MANAGEMENT-MIB | raisecomNotificationLocation |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
| SWITCH-TC | ClearVar |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IraisecomOpticalTransceiver | 1.3.6.1.4.1.8886.1.18 | ||||||||||||||||||||
identity This MIB module defines objects to monitor optical characteristics on the optical interfaces in a network element. | |||||||||||||||||||||
| NraisecomOpticalTransceiverGlobalEnable | 1.3.6.1.4.1.8886.1.18.1 | ||||||||||||||||||||
| SraisecomOpticalTransceiverNotifyEnable | 1.3.6.1.4.1.8886.1.18.1.1 | EnableVar | RW | ||||||||||||||||||
scalar · EnableVar · read-write · current This object specifies the generation of device notifications, enable or disable. this object belongs to xfp and sfp. | |||||||||||||||||||||
| SraisecomOpticalTransceiverDDMEnable | 1.3.6.1.4.1.8886.1.18.1.2 | EnableVar | RW | ||||||||||||||||||
scalar · EnableVar · read-write · current Enable or disable digitaldiagnotic on the device. this object belongs to xfp and sfp. | |||||||||||||||||||||
| SraisecomOpticalTransceiverCheckPwdEnable | 1.3.6.1.4.1.8886.1.18.1.3 | EnableVar | RW | ||||||||||||||||||
scalar · EnableVar · read-write · current This object specifies the status of password checking on the device, enable or disable. this object belongs to xfp. | |||||||||||||||||||||
| SraisecomOpticalTransceiverPollInterval | 1.3.6.1.4.1.8886.1.18.1.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This object specifies the value of poll-interval on the device. this object belongs to xfp and sfp. | |||||||||||||||||||||
| NraisecomOpticalTransceiverObjects | 1.3.6.1.4.1.8886.1.18.2 | ||||||||||||||||||||
| NraisecomOpticalTransceiverInfoGroup | 1.3.6.1.4.1.8886.1.18.2.1 | ||||||||||||||||||||
| TraisecomOpticalTransceiverInfoTable | 1.3.6.1.4.1.8886.1.18.2.1.1 | NA | |||||||||||||||||||
table · not-accessible · current Trancetver information Table. | |||||||||||||||||||||
| RraisecomOpticalTransceiverInfoEntry | 1.3.6.1.4.1.8886.1.18.2.1.1.1 | NA | |||||||||||||||||||
| CraisecomOpticalTransceiverType | 1.3.6.1.4.1.8886.1.18.2.1.1.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object specifies the physical type of the transceiver, such as xfp or sfp , and so on. this object belongs to xfp and sfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverConnectorType | 1.3.6.1.4.1.8886.1.18.2.1.1.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object specifies the connector type of the transceiver£¬ unknown, sc, db9, hssdc, bnc_tnc, fiber_coaxial_head, fiber_outlet, lc, mt_rj, mu, sg, fiber_pigtail, mpo_parallel_optic , hssdcII, copper, rj45. this object belongs to xfp and sfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverVendorName | 1.3.6.1.4.1.8886.1.18.2.1.1.1.3 | OCTET STRING | RO | ||||||||||||||||||
column · OCTET STRING · read-only · current Vendor name of the interface. this object belongs to xfp and sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverVendorPN | 1.3.6.1.4.1.8886.1.18.2.1.1.1.4 | OCTET STRING | RO | ||||||||||||||||||
column · OCTET STRING · read-only · current Vendor part number of the interface. this object belongs to xfp and sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverVendorSN | 1.3.6.1.4.1.8886.1.18.2.1.1.1.5 | OCTET STRING | RO | ||||||||||||||||||
column · OCTET STRING · read-only · current Vendor serial number of the interface. this object belongs to xfp and sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverMediaType | 1.3.6.1.4.1.8886.1.18.2.1.1.1.6 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Types of the fiber, single_mode, multi_modeE50, multi_mode50,multi_mode625,copper. single_modeKm,multi_modeOM3 this object belongs to xfp and sfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverTransmissionDistance | 1.3.6.1.4.1.8886.1.18.2.1.1.1.7 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The max distance which the interface could transmit, measured in meter. The object will be shown in unit of Km, and the precision is 0.001. this object belongs to xfp and sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverAbility | 1.3.6.1.4.1.8886.1.18.2.1.1.1.8 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current This object specifies the ability of optical module digitaldiagnotic
funtion. Currently, the digitaldiagnotic objects of our optical module
inculde 16 parameters.
this object has 32 bits, each bit represents a digital diagnotic parameter.
if the bit value is 0, it means that the optical module does not provide
digital diagnotic funtion for relative parameter.if the bit value is 1,it
means that the optical module provides digital diagnotic funtion for
relative parameter.
this object belongs to xfp and sfp.
The relation between parameters and bits is following:
32¡¡16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1:
The relation between parameters and bits is following:
32¡¡16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1:
| 1bit | 2bit | 3bit | 4bit
| APDÆ«Öõçѹ | 0£¨±£Áô£© | TECµçÁ÷ | ¼¤¹âÆ÷ζÈ
| 5bit | 6bit |7bit | 8bit
| ¼¤¹âÆ÷²¨³¤ | +5V¹©µçµçѹ | +3.3V¹©µçµçѹ | +1.8V¹©µçµçѹ
| 9bit | 10bit |11bit | 12bit
| -5.2V¹©µçµçѹ | +5V¹©µçµçÁ÷ | 0£¨ÎÞ£© | 0£¨ÎÞ£©
| 13bit | 14bit | 15bit | 16bit
| +3.3V¹©µçµçÁ÷ | +1.8V¹©µçµçÁ÷ | -5.2V¹©µçµçÁ÷ | Ä£¿éζÈ
| 17bit | 18bit | 19bit | 20bit ~ 32bit
| ¼¤¹âÆ÷Æ«ÖõçÁ÷ | ·¢Ë͹⹦ÂÊ |½ÓÊչ⹦ÂÊ | 0
But when the optical module is sfp, the 6 bit will represents
the supplyVoltage of sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverDDM | 1.3.6.1.4.1.8886.1.18.2.1.1.1.9 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object specifies if the transceiver supports on digital diagnostic function, support or not support.To the xfp, the default value of this object is support. this object belongs to xfp and sfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverCalibrationType | 1.3.6.1.4.1.8886.1.18.2.1.1.1.10 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object specifies the calibration type of the transceiver, internal, external, unknown. this object belongs to xfp and sfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverRSSI | 1.3.6.1.4.1.8886.1.18.2.1.1.1.11 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object specifies the calibration type of the transceiver, support or not support. this object belongs to xfp and sfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverVendorRev | 1.3.6.1.4.1.8886.1.18.2.1.1.1.12 | OCTET STRING | RO | ||||||||||||||||||
column · OCTET STRING · read-only · current the version number of the transceiver. this object belongs to xfp and sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverBRMax | 1.3.6.1.4.1.8886.1.18.2.1.1.1.13 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current the min data rate of the transceiver,mesured in Mbps . this object belongs to xfp and sfp. The object will be shown in unit of Gbps, and the precision is 0.1. | |||||||||||||||||||||
| CraisecomOpticalTransceiverBRMin | 1.3.6.1.4.1.8886.1.18.2.1.1.1.14 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current the min data rate of the transceiver,mesured in Mbps. this object belongs to xfp and sfp.To the sfp, the min data rate value is equal to the max data rate value. The object will be shown in unit of Gbps, and the precision is 0.1. | |||||||||||||||||||||
| CraisecomOpticalTransceiverWavelengthContrl | 1.3.6.1.4.1.8886.1.18.2.1.1.1.15 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current if the transceiver supports on wavelength control support,notsupport. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverWavelength | 1.3.6.1.4.1.8886.1.18.2.1.1.1.16 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Wavelength of the interface, measured in pm(0.001nm). this object belongs to xfp. The object will be shown in unit of nm, and the precision is 0.01. | |||||||||||||||||||||
| CraisecomOpticalTransceiverWaveTolerance | 1.3.6.1.4.1.8886.1.18.2.1.1.1.17 | OCTET STRING | RO | ||||||||||||||||||
column · OCTET STRING · read-only · current the range of laser wavelength from nominal wavelength,mesured in pm(0.001*nm). this object belongs to xfp. The object will be shown in unit of nm, and the precision is 0.01. | |||||||||||||||||||||
| CraisecomOpticalTransceiverCompatibility | 1.3.6.1.4.1.8886.1.18.2.1.1.1.18 | OCTET STRING | RO | ||||||||||||||||||
column · OCTET STRING · read-only · current the compatibility type that the transceiver supports,such as 10GBASE-SR. this object belongs to xfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPowerDissipation | 1.3.6.1.4.1.8886.1.18.2.1.1.1.19 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current the max power dissipation of the transceiver, p1W5,p2W5,p3W5,exceed3W5. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverCDR | 1.3.6.1.4.1.8886.1.18.2.1.1.1.20 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current the optical module supports on CDR fundtion. support,notsupport. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverRefClock | 1.3.6.1.4.1.8886.1.18.2.1.1.1.21 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current if the transceiver requires outside reference clock required,notrequired. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverTransmitterType | 1.3.6.1.4.1.8886.1.18.2.1.1.1.22 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The transmitter type of the transceiver,such as 850 nm VCSEL. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverCooled | 1.3.6.1.4.1.8886.1.18.2.1.1.1.24 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The transmitter cooled type of the transceiver cooled,uncooled. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverTunalbe | 1.3.6.1.4.1.8886.1.18.2.1.1.1.25 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The transmitter tunable type of the transceiver tunable,untunable. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverDetectorType | 1.3.6.1.4.1.8886.1.18.2.1.1.1.26 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The detector type of the transceiver pin, apd. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverLineLoopBack | 1.3.6.1.4.1.8886.1.18.2.1.1.1.27 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The transceiver support status of sideline loop-back control support,notsupport. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverXFILoopBack | 1.3.6.1.4.1.8886.1.18.2.1.1.1.28 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The transceiver support status of XFI loop-back control support,notsupport. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverVps | 1.3.6.1.4.1.8886.1.18.2.1.1.1.29 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object specifies if the optical module supports on VPS support,notsupport. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverTxDis | 1.3.6.1.4.1.8886.1.18.2.1.1.1.30 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The transceiver support status of software control the transmitter status support,notsupport. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverStandby | 1.3.6.1.4.1.8886.1.18.2.1.1.1.31 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The transceiver support status of software control the standby mode. support,notsupport. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverInVpsLowPower | 1.3.6.1.4.1.8886.1.18.2.1.1.1.32 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The VPS in low power support status of the transceiver support,notsupport. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverOutVpsLowPower | 1.3.6.1.4.1.8886.1.18.2.1.1.1.33 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The VPS out low power support status of the transceiver support,notsupport. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverFEC | 1.3.6.1.4.1.8886.1.18.2.1.1.1.34 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The FEC support status of transceiver support,notsupport. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverCMU | 1.3.6.1.4.1.8886.1.18.2.1.1.1.35 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The CMU support status of transceiver support,notsupport. this object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverBR | 1.3.6.1.4.1.8886.1.18.2.1.1.1.36 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object specifies the Nominal bitrate of the transceiver£¬ 125Mbps, 155Mbps, 622Mbps, 1.25Gbps, 2.5Gbps. this object belongs to xfp and sfp.
| |||||||||||||||||||||
| NraisecomOpticalTransceiverDDMGroup | 1.3.6.1.4.1.8886.1.18.2.2 | ||||||||||||||||||||
| TraisecomOpticalTransceiverDDMTable | 1.3.6.1.4.1.8886.1.18.2.2.1 | NA | |||||||||||||||||||
table · not-accessible · current This table provides objects to monitor optical parameters in a network element. | |||||||||||||||||||||
| RraisecomOpticalTransceiverDDMEntry | 1.3.6.1.4.1.8886.1.18.2.2.1.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the raisecomOpticalTransceiverMonTable provides objects to monitor an optical parameter at an optical interface. | |||||||||||||||||||||
| CraisecomOpticalTransceiverParameterType | 1.3.6.1.4.1.8886.1.18.2.2.1.1.1 | OpticalParameterType | NA | ||||||||||||||||||
column · OpticalParameterType · not-accessible · current This object specifies the optical parameter that is being monitored in this entry. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverParameterValue | 1.3.6.1.4.1.8886.1.18.2.2.1.1.2 | OpticalParameterValue | RO | -3316 | |||||||||||||||||
column · OpticalParameterValue · read-only · current This object gives the value measured for the particular optical parameter specified by the raisecomOpticalMonParameterType object. This object belongs to xfp/sfp. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CraisecomOpticalTransceiverParamHighAlarmThresh | 1.3.6.1.4.1.8886.1.18.2.2.1.1.3 | OpticalParameterValue | RO | ||||||||||||||||||
column · OpticalParameterValue · read-only · current This object gives the high alarm threshold on the optical parameter being monitored. An alarm condition will be raised if the value given by raisecomOpticalParameterValue goes from below the value of this object to above the value of this object, or if the initial value of raisecomOpticalParameterValue exceeds the value of this object. This alarm will be indicated in the raisecomOpticalParamAlarmStatus object. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverParamHighWarningThresh | 1.3.6.1.4.1.8886.1.18.2.2.1.1.4 | OpticalParameterValue | RO | ||||||||||||||||||
column · OpticalParameterValue · read-only · current This object is used to set a high warning threshold on the optical parameter being monitored. A threshold crossing condition will be indicated if the value given by raisecomOpticalParameterValue goes from below the value of this object to above the value of this object, or if the initial value of raisecomOpticalParameterValue exceeds the value of this object. This alarm will be indicated in the raisecomOpticalParamAlarmStatus object. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverParamLowAlarmThresh | 1.3.6.1.4.1.8886.1.18.2.2.1.1.5 | OpticalParameterValue | RO | ||||||||||||||||||
column · OpticalParameterValue · read-only · current This object is used to set a low alarm threshold on the optical parameter being monitored. An alarm condition will be raised if the value given by raisecomOpticalParameterValue goes from above the value of this object to below the value of this object, or if the initial value of raisecomOpticalParameterValue is lower than the value of this object. This alarm will be indicated in the raisecomOpticalParamAlarmStatus object .. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverParamLowWarningThresh | 1.3.6.1.4.1.8886.1.18.2.2.1.1.6 | OpticalParameterValue | RO | ||||||||||||||||||
column · OpticalParameterValue · read-only · current This object is used to set a low warning threshold on the optical parameter being monitored. A threshold crossing condition will be indicated if the value given by raisecomOpticalParameterValue goes from above the value of this object to below the value of this object, or if the initial value of raisecomOpticalParameterValue object is lower than the value of this object. For network elements in the status indications, this threshold violation will be indicated in the raisecomOpticalParamAlarmStatus object . This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverParamAlarmStatus | 1.3.6.1.4.1.8886.1.18.2.2.1.1.7 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object is used to indicate the current status of the thresholds for the monitored optical parameter on the interface. If a threshold is currently being exceeded on the interface, the object will be set. Otherwise, the object will be set to 1. This object belongs to xfp/sfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverParamAlarmLastValue | 1.3.6.1.4.1.8886.1.18.2.2.1.1.8 | OpticalParameterValue | RO | ||||||||||||||||||
column · OpticalParameterValue · read-only · current This object indicates the optical parameter value at the last time a threshold related to a particular optical parameter was exceeded on the interface. If no threshold value is currently being exceeded, then the value '-1000000' is returned. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverParamAlarmLastChange | 1.3.6.1.4.1.8886.1.18.2.2.1.1.9 | TimeTicks | RO | ||||||||||||||||||
column · TimeTicks · read-only · current This object specifies the value of sysUpTime at the last time a threshold related to a particular optical parameter was exceeded on the interface. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverDDM15MinValidIntervals | 1.3.6.1.4.1.8886.1.18.2.2.1.1.10 | Unsigned32 (0..96) | RO | ||||||||||||||||||
column · Unsigned32 (0..96) · read-only · current This object gives the number of previous 15 minute intervals for which valid performance monitoring data has been stored on the interface. The value of this object will be n (where n is the maximum number of 15 minute intervals supported at this interface), unless the measurement was (re-)started within the last (nx15) minutes, in which case the value will be the number of previous 15 minute intervals for which the agent has some data. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverDDM24HrValidIntervals | 1.3.6.1.4.1.8886.1.18.2.2.1.1.11 | Unsigned32 (0..7) | RO | ||||||||||||||||||
column · Unsigned32 (0..7) · read-only · current This object gives the number of previous 24 hour intervals for which valid performance monitoring data has been stored on the interface. The max value of this object is 7, it means that the user can look up 7days history information. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverDDMValidStatus | 1.3.6.1.4.1.8886.1.18.2.2.1.1.12 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object indicates the parameter row is valid or invalid. The object value is 'valide' when the module is present and supporting digitaldiagnotic. The object value is 'invalid' when the module is absent, or when the module is present and not supporting digitaldiagnotic. This object belongs to xfp/sfp.
| |||||||||||||||||||||
| NraisecomOpticalTransceiverPMGroup | 1.3.6.1.4.1.8886.1.18.2.3 | ||||||||||||||||||||
| TraisecomOpticalTransceiverPMCurrentTable | 1.3.6.1.4.1.8886.1.18.2.3.1 | NA | |||||||||||||||||||
table · not-accessible · current This table contains performance monitoring data for the various optical parameters, collected over the current 15 minute or the current 24 hour interval. | |||||||||||||||||||||
| RraisecomOpticalTransceiverPMCurrentEntry | 1.3.6.1.4.1.8886.1.18.2.3.1.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the raisecomOpticalTransceiverPMCurrentTable. It contains performance monitoring data for a monitored optical parameter at an interface, collected over the current 15 minute or the current 24 hour interval. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPMCurrentPeriod | 1.3.6.1.4.1.8886.1.18.2.3.1.1.1 | OpticalPMPeriod | NA | ||||||||||||||||||
column · OpticalPMPeriod · not-accessible · current This object indicates whether the optical parameter values given in this entry are collected over the current 15 minute or the current 24 hour interval. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPMCurrentParamType | 1.3.6.1.4.1.8886.1.18.2.3.1.1.2 | OpticalParameterType | NA | ||||||||||||||||||
column · OpticalParameterType · not-accessible · current This object specifies the optical parameter that is being monitored, in this entry. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPMCurrentMaxParam | 1.3.6.1.4.1.8886.1.18.2.3.1.1.3 | OpticalParameterValue | RO | ||||||||||||||||||
column · OpticalParameterValue · read-only · current This object gives the maximum value measured for the monitored optical parameter, in the current 15 minute or the current 24 hour interval. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPMCurrentMinParam | 1.3.6.1.4.1.8886.1.18.2.3.1.1.4 | OpticalParameterValue | RO | ||||||||||||||||||
column · OpticalParameterValue · read-only · current This object gives the minimum value measured for the monitored optical parameter, in the current 15 minute or the current 24 hour interval. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPMCurrentMeanParam | 1.3.6.1.4.1.8886.1.18.2.3.1.1.5 | OpticalParameterValue | RO | ||||||||||||||||||
column · OpticalParameterValue · read-only · current This object gives the average value of the monitored optical parameter, in the current 15 minute or the current 24 hour interval. This object belongs to xfp/sfp. | |||||||||||||||||||||
| TraisecomOpticalTransceiverPMIntervalTable | 1.3.6.1.4.1.8886.1.18.2.3.2 | NA | |||||||||||||||||||
table · not-accessible · current This table stores performance monitoring data for the various optical parameters, collected over previous intervals. This table can have entries for one complete 24 hour interval and up to 96 complete 15 minute intervals. A system is required to store at least 4 completed 15 minute intervals. The number of valid 15 minute intervals in this table is indicated by the raisecomOpticalTransceiverDDM15MinValidIntervals object and the number of valid 24 hour intervals is indicated by the raisecomOpticalTransceiverDDM24HrValidIntervals object. when the optical module is removed from the device, the relative history records will be cleaned. | |||||||||||||||||||||
| RraisecomOpticalTransceiverPMIntervalEntry | 1.3.6.1.4.1.8886.1.18.2.3.2.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the raisecomOpticalTransceiverPMIntervalTable. It contains performance monitoring data for an optical parameter, collected over a previous interval. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPMIntervalPeriod | 1.3.6.1.4.1.8886.1.18.2.3.2.1.1 | OpticalPMPeriod | NA | ||||||||||||||||||
column · OpticalPMPeriod · not-accessible · current This object indicates whether the optical parameter values, given in this entry, are collected over a period of 15 minutes or 24 hours. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPMIntervalNumber | 1.3.6.1.4.1.8886.1.18.2.3.2.1.2 | Integer32 (1..96) | NA | ||||||||||||||||||
column · Integer32 (1..96) · not-accessible · current A number between 1 and 96, which identifies the interval for which the set of optical parameter values is available. The interval identified by 1 is the most recently completed 15 minute or 24 hour interval, and the interval identified by N is the interval immediately preceding the one identified by N-1. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPMIntervalParamType | 1.3.6.1.4.1.8886.1.18.2.3.2.1.3 | OpticalParameterType | NA | ||||||||||||||||||
column · OpticalParameterType · not-accessible · current This object specifies the optical parameter that is being monitored, in this entry. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPMIntervalMaxParam | 1.3.6.1.4.1.8886.1.18.2.3.2.1.4 | OpticalParameterValue | RO | ||||||||||||||||||
column · OpticalParameterValue · read-only · current This object gives the maximum value measured for the optical parameter, in a particular 15 minute or 24 hour interval. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPMIntervalMinParam | 1.3.6.1.4.1.8886.1.18.2.3.2.1.5 | OpticalParameterValue | RO | ||||||||||||||||||
column · OpticalParameterValue · read-only · current This object gives the minimum value measured for the optical parameter, in a particular 15 minute or 24 hour interval. This object belongs to xfp/sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPMIntervalMeanParam | 1.3.6.1.4.1.8886.1.18.2.3.2.1.6 | OpticalParameterValue | RO | ||||||||||||||||||
column · OpticalParameterValue · read-only · current This object gives the average value of the measured optical parameter, in a particular 15 minute or 24 hour interval. This object belongs to xfp/sfp. | |||||||||||||||||||||
| NraisecomOpticalTransceiverStatusGroup | 1.3.6.1.4.1.8886.1.18.2.4 | ||||||||||||||||||||
| TraisecomOpticalTransceiverCurrentStatusTable | 1.3.6.1.4.1.8886.1.18.2.4.1 | NA | |||||||||||||||||||
table · not-accessible · current This table stores the hard ware information and the information set by user of the transceiver. This object belongs to xfp/sfp. | |||||||||||||||||||||
| RraisecomOpticalTransceiverCurrentStatusEntry | 1.3.6.1.4.1.8886.1.18.2.4.1.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the raisecomOpticalTransceiverCurrentStatusTable. It contains performance monitoring data for an optical parameter, collected over a previous interval. This object belongs to xfp/sfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverHwInfoAbsStatus | 1.3.6.1.4.1.8886.1.18.2.4.1.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object specifies if the optical module is absent present,absent. This object belongs to xfp and sfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverHwInfoNRStatus | 1.3.6.1.4.1.8886.1.18.2.4.1.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object specifies if the optical module is ready for operation. ready,notready. This object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverHwInfoRxLosStatus | 1.3.6.1.4.1.8886.1.18.2.4.1.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object specifies if the optical module operation losses the receiving signal normal,loss. This object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverHwInfoStandby | 1.3.6.1.4.1.8886.1.18.2.4.1.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object specifies if the optical module works under standby mode. normal,standby. This object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverHwInfoLaser | 1.3.6.1.4.1.8886.1.18.2.4.1.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object specifies if the optical module laser is turned on on,off. This object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverWaveLengthError | 1.3.6.1.4.1.8886.1.18.2.4.1.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This object specifies error between the actual wavelength and the wavelength set by the user,measured in pm. This object belongs to xfp. The object will be shown in unit of nm, and the precision is 0.001. | |||||||||||||||||||||
| CraisecomOpticalTransceiverUserWaveLength | 1.3.6.1.4.1.8886.1.18.2.4.1.1.7 | Integer32 (0..3276800) | RW | ||||||||||||||||||
column · Integer32 (0..3276800) · read-write · current This object specifies the wavelength value of the optical module set by user,measured in pm. This object belongs to xfp. The object will be shown in unit of nm, and the precision is 0.01. | |||||||||||||||||||||
| CraisecomOpticalTransceiverUserDataRate | 1.3.6.1.4.1.8886.1.18.2.4.1.1.8 | INTEGER (9500..12500) | RW | ||||||||||||||||||
column · INTEGER (9500..12500) · read-write · current This object specifies the data rate of the optical module set by user,measured in Mbps. This object belongs to xfp. The object will be shown in unit of Gbps, and the precision is 0.1. | |||||||||||||||||||||
| CraisecomOpticalTransceiverUserLineLoopBack | 1.3.6.1.4.1.8886.1.18.2.4.1.1.9 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object specifies if the sideline loop-back is tuned on , user can change the loop back mode through the object. normal,lineLoopback. This object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverUserXFILoopBack | 1.3.6.1.4.1.8886.1.18.2.4.1.1.10 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object specifies if the XFI loop-back is tuned on user can change the loop back mode through the object. normal,xfiLoopback. This object belongs to xfp.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverPortNotifyEnable | 1.3.6.1.4.1.8886.1.18.2.4.1.1.11 | EnableVar | RW | ||||||||||||||||||
column · EnableVar · read-write · current This object specifies the generation of a port notifications, enable or disable. This object belongs to xfp and sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPortDDMEnable | 1.3.6.1.4.1.8886.1.18.2.4.1.1.12 | EnableVar | RW | ||||||||||||||||||
column · EnableVar · read-write · current This object specifies the status of digitaldiagnotic on a port, enable or disable. This object belongs to xfp and sfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverPortCheckPwdEnable | 1.3.6.1.4.1.8886.1.18.2.4.1.1.13 | EnableVar | RW | ||||||||||||||||||
column · EnableVar · read-write · current This object specifies the status of password checking on a port, enable or disable. This object belongs to xfp. | |||||||||||||||||||||
| CraisecomOpticalTransceiverTxFaultCount | 1.3.6.1.4.1.8886.1.18.2.4.1.1.14 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This object specifies the number of tx-fault signals. | |||||||||||||||||||||
| CraisecomOpticalTransceiverTxFaultCountClear | 1.3.6.1.4.1.8886.1.18.2.4.1.1.15 | ClearVar | RW | ||||||||||||||||||
column · ClearVar · read-write · current This object specifies clear the statistcs of tx-fault signals. | |||||||||||||||||||||
| CraisecomOpticalTransceiverSpecificationCheckStatus | 1.3.6.1.4.1.8886.1.18.2.4.1.1.16 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object specifies the check status, accord(0)specifies the optical module accord with industrial. not-accord(2) specifies the optical module not accord with industrial.
| |||||||||||||||||||||
| CraisecomOpticalTransceiverTxFaultStatus | 1.3.6.1.4.1.8886.1.18.2.4.1.1.17 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object specifies the tx-fault status.
| |||||||||||||||||||||
| NraisecomOpticalTransceiverNotifications | 1.3.6.1.4.1.8886.1.18.3 | ||||||||||||||||||||
| !raisecomOpticalTransceiverAbsentTrap | 1.3.6.1.4.1.8886.1.18.3.1 | ||||||||||||||||||||
notification · current This notification is sent when the optical module is removed from the device. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverPresentTrap | 1.3.6.1.4.1.8886.1.18.3.2 | ||||||||||||||||||||
notification · current This notification is sent when the optical module is plugged into the device. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverNRAlarmTrap | 1.3.6.1.4.1.8886.1.18.3.3 | ||||||||||||||||||||
notification · current This notification is sent when the transmitted or received data of optical module is invalid. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverNRNormalTrap | 1.3.6.1.4.1.8886.1.18.3.4 | ||||||||||||||||||||
notification · current This notification is sent when the transmitted or received data of optical module is valid. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverRxLosAlarmTrap | 1.3.6.1.4.1.8886.1.18.3.5 | ||||||||||||||||||||
notification · current This notification is sent when the optical module receiving signal is lost. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverRxLosNormaTrap | 1.3.6.1.4.1.8886.1.18.3.6 | ||||||||||||||||||||
notification · current This notification is sent when the optical module receiving signal is back to normal. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverCheckPwdFailureTrap | 1.3.6.1.4.1.8886.1.18.3.7 | ||||||||||||||||||||
notification · current This notification is sent when the optical module password checking is failed. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverCheckPwdSucceedTrap | 1.3.6.1.4.1.8886.1.18.3.8 | ||||||||||||||||||||
notification · current This notification is sent when the optical module password cheching is successful. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverParamAlarmTrap | 1.3.6.1.4.1.8886.1.18.3.9 | ||||||||||||||||||||
notification · current This notification is sent when the optical module parameter value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverParamAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.3.10 | ||||||||||||||||||||
notification · current This notification is sent when the optical module parameter value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverParamWarningTrap | 1.3.6.1.4.1.8886.1.18.3.11 | ||||||||||||||||||||
notification · current This notification is sent when the optical module parameter value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverParamWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.3.12 | ||||||||||||||||||||
notification · current This notification is sent when the optical module parameter value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverLaserBackLightAlarmTrap | 1.3.6.1.4.1.8886.1.18.3.13 | ||||||||||||||||||||
notification · current This notification is sent when the optical module password cheching is successful. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverLaserBackLightAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.3.14 | ||||||||||||||||||||
notification · current This notification is sent when the optical module password cheching is successful. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverLaserLifeAlarmTrap | 1.3.6.1.4.1.8886.1.18.3.15 | ||||||||||||||||||||
notification · current This notification is sent when the optical module password cheching is successful. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverLaserLifeAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.3.16 | ||||||||||||||||||||
notification · current This notification is sent when the optical module password cheching is successful. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverParamLowAlarmTrap | 1.3.6.1.4.1.8886.1.18.3.17 | ||||||||||||||||||||
notification · current This notification is sent when the optical module parameter value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverParamLowAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.3.18 | ||||||||||||||||||||
notification · current This notification is sent when the optical module parameter value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverParamLowWarningTrap | 1.3.6.1.4.1.8886.1.18.3.19 | ||||||||||||||||||||
notification · current This notification is sent when the optical module parameter value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverParamLowWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.3.20 | ||||||||||||||||||||
notification · current This notification is sent when the optical module parameter value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| NraisecomOpticalTransceiverParamNotifications | 1.3.6.1.4.1.8886.1.18.4 | ||||||||||||||||||||
| !raisecomOpticalTransceiverTemperatureAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.1 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Temperature value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTemperatureAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.2 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Temperature value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTemperatureWarningTrap | 1.3.6.1.4.1.8886.1.18.4.3 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Temperature value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTemperatureWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.4 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Temperature value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTxbiasCurrentAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.5 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Tx bias Current value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTxbiasCurrentAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.6 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Tx bias Current value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTxbiasCurrentWarningTrap | 1.3.6.1.4.1.8886.1.18.4.7 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Tx bias Current value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTxbiasCurrentWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.8 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Tx bias Current value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTxPowerAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.9 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Tx Power value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTxPowerAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.10 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Tx Power value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTxPowerWarningTrap | 1.3.6.1.4.1.8886.1.18.4.11 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Tx Power value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTxPowerWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.12 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Tx Power value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverRxPowerAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.13 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Rx Power value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverRxPowerWarningTrap | 1.3.6.1.4.1.8886.1.18.4.14 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Rx Power value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverRxPowerWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.15 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Rx Power value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverRxPowerAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.16 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Rx Power value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverLaserTemperatureAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.17 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Laser Temperature value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverLaserTemperatureWarningTrap | 1.3.6.1.4.1.8886.1.18.4.18 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Laser Temperature value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverLaserTemperatureWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.19 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Laser Temperature value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverLaserTemperatureAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.20 | ||||||||||||||||||||
notification · current This notification is sent when the optical module Laser Temperature value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP5V0supplyVoltageAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.21 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +5.0V supply Voltage value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP5V0supplyVoltageWarningTrap | 1.3.6.1.4.1.8886.1.18.4.22 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +5.0V supply Voltage value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP5V0supplyVoltageWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.23 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +5.0V supply Voltage value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP5V0supplyVoltageAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.24 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +5.0V supply Voltage value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP3V3supplyVoltageAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.25 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +3.3V supply Voltage value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP3V3supplyVoltageWarningTrap | 1.3.6.1.4.1.8886.1.18.4.26 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +3.3V supply Voltage value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP3V3supplyVoltageWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.27 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +3.3V supply Voltage value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP3V3supplyVoltageAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.28 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +3.3V supply Voltage value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP1V8supplyVoltageAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.29 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +1.8v supply Voltage value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP1V8supplyVoltageWarningTrap | 1.3.6.1.4.1.8886.1.18.4.30 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +1.8v supply Voltage value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP1V8supplyVoltageWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.31 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +1.8v supply Voltage value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP1V8supplyVoltageAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.32 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +1.8v supply Voltage value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverN5V2supplyVoltageAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.33 | ||||||||||||||||||||
notification · current This notification is sent when the optical module -5.2v supply Voltage value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverN5V2supplyVoltageWarningTrap | 1.3.6.1.4.1.8886.1.18.4.34 | ||||||||||||||||||||
notification · current This notification is sent when the optical module -5.2v supply Voltage value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverN5V2supplyVoltageWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.35 | ||||||||||||||||||||
notification · current This notification is sent when the optical module -5.2v supply Voltage value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverN5V2supplyVoltageAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.36 | ||||||||||||||||||||
notification · current This notification is sent when the optical module -5.2v supply Voltage value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverApdBiasVoltageAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.37 | ||||||||||||||||||||
notification · current This notification is sent when the optical module APD Bias Voltage value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverApdBiasVoltageWarningTrap | 1.3.6.1.4.1.8886.1.18.4.38 | ||||||||||||||||||||
notification · current This notification is sent when the optical module APD Bias Voltage value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverApdBiasVoltageWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.39 | ||||||||||||||||||||
notification · current This notification is sent when the optical module APD Bias Voltage value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverApdBiasVoltageAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.40 | ||||||||||||||||||||
notification · current This notification is sent when the optical module APD Bias Voltage value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP5V0supplyCurrentAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.41 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +5.0V supply Current value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP5V0supplyCurrentWarningTrap | 1.3.6.1.4.1.8886.1.18.4.42 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +5.0V supply Current value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP5V0supplyCurrentWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.43 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +5.0V supply Current value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP5V0supplyCurrentAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.44 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +5.0V supply Current value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP3V3supplyCurrentAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.45 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +3.3V supply Current value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP3V3supplyCurrentWarningTrap | 1.3.6.1.4.1.8886.1.18.4.46 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +3.3V supply Current value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP3V3supplyCurrentWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.47 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +3.3V supply Current value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP3V3supplyCurrentAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.48 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +3.3V supply Current value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP1V8supplyCurrentAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.49 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +1.8V supply Current value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP1V8supplyCurrentWarningTrap | 1.3.6.1.4.1.8886.1.18.4.50 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +1.8V supply Current value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP1V8supplyCurrentWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.51 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +1.8V supply Current value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverP1V8supplyCurrentAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.52 | ||||||||||||||||||||
notification · current This notification is sent when the optical module +1.8V supply Current value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverN5V2supplyCurrentAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.53 | ||||||||||||||||||||
notification · current This notification is sent when the optical module -5.2V supply Current value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverN5V2supplyCurrentWarningTrap | 1.3.6.1.4.1.8886.1.18.4.54 | ||||||||||||||||||||
notification · current This notification is sent when the optical module -5.2V supply Current value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverN5V2supplyCurrentWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.55 | ||||||||||||||||||||
notification · current This notification is sent when the optical module -5.2V supply Current value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverN5V2supplyCurrentAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.56 | ||||||||||||||||||||
notification · current This notification is sent when the optical module -5.2V supply Current value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTecCurrentAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.57 | ||||||||||||||||||||
notification · current This notification is sent when the optical module TecCurrent value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTecCurrentWarningTrap | 1.3.6.1.4.1.8886.1.18.4.58 | ||||||||||||||||||||
notification · current This notification is sent when the optical module TecCurrent value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTecCurrentWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.59 | ||||||||||||||||||||
notification · current This notification is sent when the optical module TecCurrent value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTecCurrentAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.60 | ||||||||||||||||||||
notification · current This notification is sent when the optical module TecCurrent value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverLaserWavelengthAlarmTrap | 1.3.6.1.4.1.8886.1.18.4.61 | ||||||||||||||||||||
notification · current This notification is sent when the optical module laserWavelength value increase to above the high alarm threshold or dicrease to under the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverLaserWavelengthWarningTrap | 1.3.6.1.4.1.8886.1.18.4.62 | ||||||||||||||||||||
notification · current This notification is sent when the optical module laserWavelength value increase to above the high warning threshold or dicrease to under the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverLaserWavelengthWarningNormalTrap | 1.3.6.1.4.1.8886.1.18.4.63 | ||||||||||||||||||||
notification · current This notification is sent when the optical module laserWavelength value dicrease to under the high warning threshold or increase to above the low warning threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverLaserWavelengthAlarmNormalTrap | 1.3.6.1.4.1.8886.1.18.4.64 | ||||||||||||||||||||
notification · current This notification is sent when the optical module laserWavelength value dicrease to under the high alarm threshold or increase to above the low alarm threshold. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTxFaultTrap | 1.3.6.1.4.1.8886.1.18.4.65 | ||||||||||||||||||||
notification · current This notification is sent when the SFP optical module occures Tx-fault signal. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
| !raisecomOpticalTransceiverTxNormalTrap | 1.3.6.1.4.1.8886.1.18.4.66 | ||||||||||||||||||||
notification · current This notification is sent when the SFP optical module cancels the Tx-fault signal. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. | |||||||||||||||||||||
Textual conventions
EnableVarINTEGERdisable(2)enable(1)enable or disable a function.
OpticalPMPeriodINTEGERfifteenMin(1)twentyFourHour(2)This value indicates the time period over which performance monitoring data has been collected.
OpticalParameterTypeINTEGERapdBiasVoltage(10)laserTemperature(5)laserWavelength(16)n5V2supplyCurrent(14)n5V2supplyVoltage(9)p1V8supplyCurrent(13)p1V8supplyVoltage(8)p3V3supplyCurrent(12)p3V3supplyVoltage(7)p5V0supplyCurrent(11)p5V0supplyVoltage(6)rxPower(4)tecCurrent(15)transceiverTemperature(1)txPower(3)txbiasCurrent(2)This value indicates the optical parameter that is being monitored. Valid values are -OpticalParameterType transceiverTemperature(1) :transceiver temperature txbiasCurrent(2) :TX bias current txPower(3) :TX output power rxPower(4) :RX received optical power laserTemperature(5) :laser temperature p5V0supplyVoltage(6) :+5V supply voltage p3V3supplyVoltage(7) :+3.3V supply voltage p1V8supplyVoltage(8) :+1.8V supply voltage n5V2supplyVoltage(9) :-5.2V supply voltage apdBiasVoltage(10) :APD bias voltage p5V0supplyCurrent(11) :+5V supply currnet p3V3supplyCurrent(12) :+3.3V supply currnet p1V8supplyCurrent(13) :+1.8V supply currnet n5V2supplyCurrent(14) :-5.2V supply currnet tecCurrent(15) :TEC currnet laserWavelength(16) :laser wavelength
OpticalParameterValueInteger32 (-1000000 | -40000..6553600)The value of the optical parameter that is being monitored. The range of values varies depending on the type of optical parameter being monitored, as identified by a corresponding object with syntax OpticalParameterType. When the optical parameter being monitored is 'XXTemperature',the supported range is from -40000 to 125000, in units of 1/1000 degrees centigrade. Example: A value of 23500 represents a temperature reading of 23.5 degrees C. The temperature is shown in unit of degrees centigrade, and the precision is 0.1. When the optical parameter being monitored is 'txbiasCurrent',the supported range is from 0 to 131000, in units of 1/1000 mA. Example: A value of 1000 represents a TX bias current reading of 1.0mA. The 'txbiasCurrent'is shown in unit of mA, and the precision is 0.1. When the optical parameter being monitored is 'txPower',the supported range is from -40000 to 8200, in units of 1/1000 dbm. Example: A value of 77800 represents a TX output power reading of 7.78 dBm. The 'txPower' is shown in unit of dBm, and the precision is 0.1. When the optical parameter being monitored is 'rxPower',the supported range is from -40000 to 8200, in units of 1/1000 dbm. Example: A value of 7780 represents a RX received optical power reading of 7.78 dBm. The 'rxPower' is shown in unit of dBm, and the precision is 0.1. When the optical parameter being monitored is 'XXsupplyVoltage',the supported range is from 0 to 6550, in units of 1/1000 V. Example: A value of 6000 represents a XX supply Voltage eading of 6.00V. The 'XXsupplyVoltage'is shown in unit of V, and the precision is 0.01. When the optical parameter being monitored is 'apdBiasVoltage,the supported range is from 0 to 655300 , in units of 1/1000 V . Example: A value of 600000 represents a APD BiasVoltage reading of 600.0V. The 'apdBiasVoltage' is shown in unit of V, and the precision is 0.1. When the optical parameter being monitored is 'XXsupplyCurrent',the supported range is from 0 to 6553600, in units of 1/1000 mA . Example: A value of 6000000 represents a XX supply current reading of 6000.0mA. The 'XXsupplyCurrent' is shown in unit of mA, and the precision is 0.1. When the optical parameter being monitored is 'tecCurrent',the supported range is from 0 to 6553600, in units of 1/1000 mA . Example: A value of 6000000 represents a TEC Current reading of 6000.0mA. The 'tecCurrent' is shown in unit of mA, and the precision is 0.1. When the optical parameter being monitored is 'laserWavelength,the supported range is from 0 to 3276750, in units of 1/1000 nm . Example: A value of 3000000 represents a laser wavelength reading of 3000.0nm. The 'laserWavelength'is shown in unit of nm, and the precision is 0.01.
Traps / Notifications
- raisecomOpticalTransceiverAbsentTrap
1.3.6.1.4.1.8886.1.18.3.1 - raisecomOpticalTransceiverApdBiasVoltageAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.40 - raisecomOpticalTransceiverApdBiasVoltageAlarmTrap
1.3.6.1.4.1.8886.1.18.4.37 - raisecomOpticalTransceiverApdBiasVoltageWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.39 - raisecomOpticalTransceiverApdBiasVoltageWarningTrap
1.3.6.1.4.1.8886.1.18.4.38 - raisecomOpticalTransceiverCheckPwdFailureTrap
1.3.6.1.4.1.8886.1.18.3.7 - raisecomOpticalTransceiverCheckPwdSucceedTrap
1.3.6.1.4.1.8886.1.18.3.8 - raisecomOpticalTransceiverLaserBackLightAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.3.14 - raisecomOpticalTransceiverLaserBackLightAlarmTrap
1.3.6.1.4.1.8886.1.18.3.13 - raisecomOpticalTransceiverLaserLifeAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.3.16 - raisecomOpticalTransceiverLaserLifeAlarmTrap
1.3.6.1.4.1.8886.1.18.3.15 - raisecomOpticalTransceiverLaserTemperatureAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.20 - raisecomOpticalTransceiverLaserTemperatureAlarmTrap
1.3.6.1.4.1.8886.1.18.4.17 - raisecomOpticalTransceiverLaserTemperatureWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.19 - raisecomOpticalTransceiverLaserTemperatureWarningTrap
1.3.6.1.4.1.8886.1.18.4.18 - raisecomOpticalTransceiverLaserWavelengthAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.64 - raisecomOpticalTransceiverLaserWavelengthAlarmTrap
1.3.6.1.4.1.8886.1.18.4.61 - raisecomOpticalTransceiverLaserWavelengthWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.63 - raisecomOpticalTransceiverLaserWavelengthWarningTrap
1.3.6.1.4.1.8886.1.18.4.62 - raisecomOpticalTransceiverN5V2supplyCurrentAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.56 - raisecomOpticalTransceiverN5V2supplyCurrentAlarmTrap
1.3.6.1.4.1.8886.1.18.4.53 - raisecomOpticalTransceiverN5V2supplyCurrentWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.55 - raisecomOpticalTransceiverN5V2supplyCurrentWarningTrap
1.3.6.1.4.1.8886.1.18.4.54 - raisecomOpticalTransceiverN5V2supplyVoltageAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.36 - raisecomOpticalTransceiverN5V2supplyVoltageAlarmTrap
1.3.6.1.4.1.8886.1.18.4.33 - raisecomOpticalTransceiverN5V2supplyVoltageWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.35 - raisecomOpticalTransceiverN5V2supplyVoltageWarningTrap
1.3.6.1.4.1.8886.1.18.4.34 - raisecomOpticalTransceiverNRAlarmTrap
1.3.6.1.4.1.8886.1.18.3.3 - raisecomOpticalTransceiverNRNormalTrap
1.3.6.1.4.1.8886.1.18.3.4 - raisecomOpticalTransceiverP1V8supplyCurrentAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.52 - raisecomOpticalTransceiverP1V8supplyCurrentAlarmTrap
1.3.6.1.4.1.8886.1.18.4.49 - raisecomOpticalTransceiverP1V8supplyCurrentWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.51 - raisecomOpticalTransceiverP1V8supplyCurrentWarningTrap
1.3.6.1.4.1.8886.1.18.4.50 - raisecomOpticalTransceiverP1V8supplyVoltageAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.32 - raisecomOpticalTransceiverP1V8supplyVoltageAlarmTrap
1.3.6.1.4.1.8886.1.18.4.29 - raisecomOpticalTransceiverP1V8supplyVoltageWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.31 - raisecomOpticalTransceiverP1V8supplyVoltageWarningTrap
1.3.6.1.4.1.8886.1.18.4.30 - raisecomOpticalTransceiverP3V3supplyCurrentAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.48 - raisecomOpticalTransceiverP3V3supplyCurrentAlarmTrap
1.3.6.1.4.1.8886.1.18.4.45 - raisecomOpticalTransceiverP3V3supplyCurrentWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.47 - raisecomOpticalTransceiverP3V3supplyCurrentWarningTrap
1.3.6.1.4.1.8886.1.18.4.46 - raisecomOpticalTransceiverP3V3supplyVoltageAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.28 - raisecomOpticalTransceiverP3V3supplyVoltageAlarmTrap
1.3.6.1.4.1.8886.1.18.4.25 - raisecomOpticalTransceiverP3V3supplyVoltageWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.27 - raisecomOpticalTransceiverP3V3supplyVoltageWarningTrap
1.3.6.1.4.1.8886.1.18.4.26 - raisecomOpticalTransceiverP5V0supplyCurrentAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.44 - raisecomOpticalTransceiverP5V0supplyCurrentAlarmTrap
1.3.6.1.4.1.8886.1.18.4.41 - raisecomOpticalTransceiverP5V0supplyCurrentWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.43 - raisecomOpticalTransceiverP5V0supplyCurrentWarningTrap
1.3.6.1.4.1.8886.1.18.4.42 - raisecomOpticalTransceiverP5V0supplyVoltageAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.24 - raisecomOpticalTransceiverP5V0supplyVoltageAlarmTrap
1.3.6.1.4.1.8886.1.18.4.21 - raisecomOpticalTransceiverP5V0supplyVoltageWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.23 - raisecomOpticalTransceiverP5V0supplyVoltageWarningTrap
1.3.6.1.4.1.8886.1.18.4.22 - raisecomOpticalTransceiverParamAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.3.10 - raisecomOpticalTransceiverParamAlarmTrap
1.3.6.1.4.1.8886.1.18.3.9 - raisecomOpticalTransceiverParamLowAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.3.18 - raisecomOpticalTransceiverParamLowAlarmTrap
1.3.6.1.4.1.8886.1.18.3.17 - raisecomOpticalTransceiverParamLowWarningNormalTrap
1.3.6.1.4.1.8886.1.18.3.20 - raisecomOpticalTransceiverParamLowWarningTrap
1.3.6.1.4.1.8886.1.18.3.19 - raisecomOpticalTransceiverParamWarningNormalTrap
1.3.6.1.4.1.8886.1.18.3.12 - raisecomOpticalTransceiverParamWarningTrap
1.3.6.1.4.1.8886.1.18.3.11 - raisecomOpticalTransceiverPresentTrap
1.3.6.1.4.1.8886.1.18.3.2 - raisecomOpticalTransceiverRxLosAlarmTrap
1.3.6.1.4.1.8886.1.18.3.5 - raisecomOpticalTransceiverRxLosNormaTrap
1.3.6.1.4.1.8886.1.18.3.6 - raisecomOpticalTransceiverRxPowerAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.16 - raisecomOpticalTransceiverRxPowerAlarmTrap
1.3.6.1.4.1.8886.1.18.4.13 - raisecomOpticalTransceiverRxPowerWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.15 - raisecomOpticalTransceiverRxPowerWarningTrap
1.3.6.1.4.1.8886.1.18.4.14 - raisecomOpticalTransceiverTecCurrentAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.60 - raisecomOpticalTransceiverTecCurrentAlarmTrap
1.3.6.1.4.1.8886.1.18.4.57 - raisecomOpticalTransceiverTecCurrentWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.59 - raisecomOpticalTransceiverTecCurrentWarningTrap
1.3.6.1.4.1.8886.1.18.4.58 - raisecomOpticalTransceiverTemperatureAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.2 - raisecomOpticalTransceiverTemperatureAlarmTrap
1.3.6.1.4.1.8886.1.18.4.1 - raisecomOpticalTransceiverTemperatureWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.4 - raisecomOpticalTransceiverTemperatureWarningTrap
1.3.6.1.4.1.8886.1.18.4.3 - raisecomOpticalTransceiverTxFaultTrap
1.3.6.1.4.1.8886.1.18.4.65 - raisecomOpticalTransceiverTxNormalTrap
1.3.6.1.4.1.8886.1.18.4.66 - raisecomOpticalTransceiverTxPowerAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.10 - raisecomOpticalTransceiverTxPowerAlarmTrap
1.3.6.1.4.1.8886.1.18.4.9 - raisecomOpticalTransceiverTxPowerWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.12 - raisecomOpticalTransceiverTxPowerWarningTrap
1.3.6.1.4.1.8886.1.18.4.11 - raisecomOpticalTransceiverTxbiasCurrentAlarmNormalTrap
1.3.6.1.4.1.8886.1.18.4.6 - raisecomOpticalTransceiverTxbiasCurrentAlarmTrap
1.3.6.1.4.1.8886.1.18.4.5 - raisecomOpticalTransceiverTxbiasCurrentWarningNormalTrap
1.3.6.1.4.1.8886.1.18.4.8 - raisecomOpticalTransceiverTxbiasCurrentWarningTrap
1.3.6.1.4.1.8886.1.18.4.7