RAISECOM-OPTICAL-MONITOR-MIB
Beijing Raisecom Scientific & Technology Development Co., Ltd.This MIB module defines objects to monitor optical characteristics on the optical interfaces in a network element.
snmptranslate -m RAISECOM-OPTICAL-MONITOR-MIB -Tpsnmpwalk -v2c -c <community> -m RAISECOM-OPTICAL-MONITOR-MIB <host> 1.3.6.1.4.1.8886.1.9Imports
| IF-MIB | ifIndex |
|---|---|
| RAISECOM-BASE-MIB | raisecomAgent |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
| SWITCH-TC | EnableVar |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| IraisecomOpticalMonitorMIB | 1.3.6.1.4.1.8886.1.9 | |||
identity This MIB module defines objects to monitor optical characteristics on the optical interfaces in a network element. | ||||
| NraisecomOpticalMonitorMIBObjects | 1.3.6.1.4.1.8886.1.9.1 | |||
| NraisecomOpticalMonGroup | 1.3.6.1.4.1.8886.1.9.1.1 | |||
| TraisecomOpticalMonTable | 1.3.6.1.4.1.8886.1.9.1.1.1 | NA | ||
table · not-accessible · current This table provides objects to monitor optical parameters in a network element. | ||||
| RraisecomOpticalMonEntry | 1.3.6.1.4.1.8886.1.9.1.1.1.1 | NA | ||
row · not-accessible · current An entry in the raisecomOpticalMonTable provides objects to monitor an optical parameter at an optical interface. | ||||
| CraisecomOpticalMonParameterType | 1.3.6.1.4.1.8886.1.9.1.1.1.1.1 | OpticalParameterType | NA | |
column · OpticalParameterType · not-accessible · current This object specifies the optical parameter that is being monitored in this entry. | ||||
| CraisecomOpticalParameterValue | 1.3.6.1.4.1.8886.1.9.1.1.1.1.2 | OpticalParameterValue | RO | |
column · OpticalParameterValue · read-only · current This object gives the value measured for the particular optical parameter specified by the raisecomOpticalMonParameterType object. | ||||
| CraisecomOpticalParamHighAlarmThresh | 1.3.6.1.4.1.8886.1.9.1.1.1.1.3 | OpticalParameterValue | RO | |
column · OpticalParameterValue · read-only · current This object gives the high alarm threshold on the optical parameter being monitored. An alarm condition will be raised if the value given by raisecomOpticalParameterValue goes from below the value of this object to above the value of this object, or if the initial value of raisecomOpticalParameterValue exceeds the value of this object. This alarm will be indicated in the raisecomOpticalParamAlarmStatus object. | ||||
| CraisecomOpticalParamHighWarningThresh | 1.3.6.1.4.1.8886.1.9.1.1.1.1.4 | OpticalParameterValue | RO | |
column · OpticalParameterValue · read-only · current This object is used to set a high warning threshold on the optical parameter being monitored. A threshold crossing condition will be indicated if the value given by raisecomOpticalParameterValue goes from below the value of this object to above the value of this object, or if the initial value of raisecomOpticalParameterValue exceeds the value of this object. This alarm will be indicated in the raisecomOpticalParamAlarmStatus object. | ||||
| CraisecomOpticalParamLowAlarmThresh | 1.3.6.1.4.1.8886.1.9.1.1.1.1.5 | OpticalParameterValue | RO | |
column · OpticalParameterValue · read-only · current This object is used to set a low alarm threshold on the optical parameter being monitored. An alarm condition will be raised if the value given by raisecomOpticalParameterValue goes from above the value of this object to below the value of this object, or if the initial value of raisecomOpticalParameterValue is lower than the value of this object. This alarm will be indicated in the raisecomOpticalParamAlarmStatus object .. | ||||
| CraisecomOpticalParamLowWarningThresh | 1.3.6.1.4.1.8886.1.9.1.1.1.1.6 | OpticalParameterValue | RO | |
column · OpticalParameterValue · read-only · current This object is used to set a low warning threshold on the optical parameter being monitored. A threshold crossing condition will be indicated if the value given by raisecomOpticalParameterValue goes from above the value of this object to below the value of this object, or if the initial value of raisecomOpticalParameterValue object is lower than the value of this object. For network elements in the status indications, this threshold violation will be indicated in the raisecomOpticalParamAlarmStatus object . | ||||
| CraisecomOpticalParamAlarmStatus | 1.3.6.1.4.1.8886.1.9.1.1.1.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current This object is used to indicate the current status of the thresholds for the monitored optical parameter on the interface. If a threshold is currently being exceeded on the interface, the object will be set. Otherwise, the object will be set to 0.
| ||||
| CraisecomOpticalParamAlarmLastValue | 1.3.6.1.4.1.8886.1.9.1.1.1.1.8 | OpticalParameterValue | RO | |
column · OpticalParameterValue · read-only · current This object indicates the optical parameter value at the last time a threshold related to a particular optical parameter was exceeded on the interface. If no threshold value is currently being exceeded, then the value '-1000000' is returned. | ||||
| CraisecomOpticalParamAlarmLastChange | 1.3.6.1.4.1.8886.1.9.1.1.1.1.9 | TimeTicks | RO | |
column · TimeTicks · read-only · current This object specifies the value of sysUpTime at the last time a threshold related to a particular optical parameter was exceeded on the interface. | ||||
| CraisecomOpticalMon15MinValidIntervals | 1.3.6.1.4.1.8886.1.9.1.1.1.1.10 | Unsigned32 (0..96) | RO | |
column · Unsigned32 (0..96) · read-only · current This object gives the number of previous 15 minute intervals for which valid performance monitoring data has been stored on the interface. The value of this object will be n (where n is the maximum number of 15 minute intervals supported at this interface), unless the measurement was (re-)started within the last (nx15) minutes, in which case the value will be the number of previous 15 minute intervals for which the agent has some data. | ||||
| CraisecomOpticalMon24HrValidIntervals | 1.3.6.1.4.1.8886.1.9.1.1.1.1.11 | Unsigned32 (0..1) | RO | |
column · Unsigned32 (0..1) · read-only · current This object gives the number of previous 24 hour intervals for which valid performance monitoring data has been stored on the interface. The value of this object will be 0 if the measurement was (re-)started within the last 24 hours, or 1 otherwise. | ||||
| CraisecomOpticalMonValidStatus | 1.3.6.1.4.1.8886.1.9.1.1.1.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current This object indicates the parameter row is valid or not.
| ||||
| SraisecomOpticalNotifyEnable | 1.3.6.1.4.1.8886.1.9.1.1.2 | EnableVar | RW | |
scalar · EnableVar · read-write · current This object specifies the generation of raisecomOpticalMonParameterStatus notifications. | ||||
| SraisecomOpticalDigitalDiagnoticEnable | 1.3.6.1.4.1.8886.1.9.1.1.3 | EnableVar | RW | |
scalar · EnableVar · read-write · current Enable or disable digitaldiagnotic on the switch. | ||||
| NraisecomOpticalPMGroup | 1.3.6.1.4.1.8886.1.9.1.2 | |||
| TraisecomOpticalPMCurrentTable | 1.3.6.1.4.1.8886.1.9.1.2.1 | NA | ||
table · not-accessible · current This table contains performance monitoring data for the various optical parameters, collected over the current 15 minute or the current 24 hour interval. | ||||
| RraisecomOpticalPMCurrentEntry | 1.3.6.1.4.1.8886.1.9.1.2.1.1 | NA | ||
row · not-accessible · current An entry in the raisecomOpticalPMCurrentTable. It contains performance monitoring data for a monitored optical parameter at an interface, collected over the current 15 minute or the current 24 hour interval. | ||||
| CraisecomOpticalPMCurrentPeriod | 1.3.6.1.4.1.8886.1.9.1.2.1.1.1 | OpticalPMPeriod | NA | |
column · OpticalPMPeriod · not-accessible · current This object indicates whether the optical parameter values given in this entry are collected over the current 15 minute or the current 24 hour interval. | ||||
| CraisecomOpticalPMCurrentParamType | 1.3.6.1.4.1.8886.1.9.1.2.1.1.2 | OpticalParameterType | NA | |
column · OpticalParameterType · not-accessible · current This object specifies the optical parameter that is being monitored, in this entry. | ||||
| CraisecomOpticalPMCurrentMaxParam | 1.3.6.1.4.1.8886.1.9.1.2.1.1.3 | OpticalParameterValue | RO | |
column · OpticalParameterValue · read-only · current This object gives the maximum value measured for the monitored optical parameter, in the current 15 minute or the current 24 hour interval. | ||||
| CraisecomOpticalPMCurrentMinParam | 1.3.6.1.4.1.8886.1.9.1.2.1.1.4 | OpticalParameterValue | RO | |
column · OpticalParameterValue · read-only · current This object gives the minimum value measured for the monitored optical parameter, in the current 15 minute or the current 24 hour interval. | ||||
| CraisecomOpticalPMCurrentMeanParam | 1.3.6.1.4.1.8886.1.9.1.2.1.1.5 | OpticalParameterValue | RO | |
column · OpticalParameterValue · read-only · current This object gives the average value of the monitored optical parameter, in the current 15 minute or the current 24 hour interval. | ||||
| TraisecomOpticalPMIntervalTable | 1.3.6.1.4.1.8886.1.9.1.2.2 | NA | ||
table · not-accessible · current This table stores performance monitoring data for the various optical parameters, collected over previous intervals. This table can have entries for one complete 24 hour interval and up to 96 complete 15 minute intervals. A system is required to store at least 4 completed 15 minute intervals. The number of valid 15 minute intervals in this table is indicated by the cOpticalMon15MinValidIntervals object and the number of valid 24 hour intervals is indicated by the cOpticalMon24HrValidIntervals object. | ||||
| RraisecomOpticalPMIntervalEntry | 1.3.6.1.4.1.8886.1.9.1.2.2.1 | NA | ||
row · not-accessible · current An entry in the raisecomOpticalPMIntervalTable. It contains performance monitoring data for an optical parameter, collected over a previous interval. | ||||
| CraisecomOpticalPMIntervalPeriod | 1.3.6.1.4.1.8886.1.9.1.2.2.1.1 | OpticalPMPeriod | NA | |
column · OpticalPMPeriod · not-accessible · current This object indicates whether the optical parameter values, given in this entry, are collected over a period of 15 minutes or 24 hours. | ||||
| CraisecomOpticalPMIntervalNumber | 1.3.6.1.4.1.8886.1.9.1.2.2.1.2 | Integer32 (1..96) | NA | |
column · Integer32 (1..96) · not-accessible · current A number between 1 and 96, which identifies the interval for which the set of optical parameter values is available. The interval identified by 1 is the most recently completed 15 minute or 24 hour interval, and the interval identified by N is the interval immediately preceding the one identified by N-1. | ||||
| CraisecomOpticalPMIntervalParamType | 1.3.6.1.4.1.8886.1.9.1.2.2.1.3 | OpticalParameterType | NA | |
column · OpticalParameterType · not-accessible · current This object specifies the optical parameter that is being monitored, in this entry. | ||||
| CraisecomOpticalPMIntervalMaxParam | 1.3.6.1.4.1.8886.1.9.1.2.2.1.4 | OpticalParameterValue | RO | |
column · OpticalParameterValue · read-only · current This object gives the maximum value measured for the optical parameter, in a particular 15 minute or 24 hour interval. | ||||
| CraisecomOpticalPMIntervalMinParam | 1.3.6.1.4.1.8886.1.9.1.2.2.1.5 | OpticalParameterValue | RO | |
column · OpticalParameterValue · read-only · current This object gives the minimum value measured for the optical parameter, in a particular 15 minute or 24 hour interval. | ||||
| CraisecomOpticalPMIntervalMeanParam | 1.3.6.1.4.1.8886.1.9.1.2.2.1.6 | OpticalParameterValue | RO | |
column · OpticalParameterValue · read-only · current This object gives the average value of the measured optical parameter, in a particular 15 minute or 24 hour interval. | ||||
| TraisecomTranceiverInfoTable | 1.3.6.1.4.1.8886.1.9.1.4 | NA | ||
table · not-accessible · current Trancetver information Table. | ||||
| RraisecomTranceiverInfoEntry | 1.3.6.1.4.1.8886.1.9.1.4.1 | NA | ||
| CraisecomTranceiverType | 1.3.6.1.4.1.8886.1.9.1.4.1.1 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current Type of the interface, such as 1000_BASE_SX_SFP | ||||
| CraisecomTranceiverConnectorType | 1.3.6.1.4.1.8886.1.9.1.4.1.2 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current ConnectorType of the interface, such as SC/LC | ||||
| CraisecomTranceiverWavelength | 1.3.6.1.4.1.8886.1.9.1.4.1.3 | Integer32 | RO | |
column · Integer32 · read-only · current Wavelength of the interface, measured in nm. | ||||
| CraisecomTranceiverVendorName | 1.3.6.1.4.1.8886.1.9.1.4.1.4 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current Vendor name of the interface. | ||||
| CraisecomTranceiverVendorPN | 1.3.6.1.4.1.8886.1.9.1.4.1.5 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current Vendor part number of the interface. | ||||
| CraisecomTranceiverVendorSN | 1.3.6.1.4.1.8886.1.9.1.4.1.6 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current Vendor serial number of the interface. | ||||
| CraisecomTransceiverFiberType | 1.3.6.1.4.1.8886.1.9.1.4.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current Types of the fiber, single_mode, multi_mode, none.
| ||||
| CraisecomTransceiverTransferDistance | 1.3.6.1.4.1.8886.1.9.1.4.1.8 | Integer32 | RO | |
column · Integer32 · read-only · current The max distance which the interface could transmit, measured in meter. | ||||
| NraisecomOpticalMonitorMIBNotifications | 1.3.6.1.4.1.8886.1.9.2 | |||
| !raisecomOpticalMonParameterStatus | 1.3.6.1.4.1.8886.1.9.2.1 | |||
notification · current This notification is sent when any threshold related to an optical parameter is exceeded on an interface. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable object. | ||||
| NraisecomOpticalMonitorMIBConformance | 1.3.6.1.4.1.8886.1.9.3 | |||
| NraisecomOpticalMonitorMIBCompliances | 1.3.6.1.4.1.8886.1.9.3.1 | |||
| MraisecomOpticalMonitorMIBCompliance | 1.3.6.1.4.1.8886.1.9.3.1.1 | |||
compliance · current The compliance statement for network elements that monitor optical characteristics and thresholds on the optical interfaces in a network element. | ||||
| NraisecomOpticalMonitorMIBGroups | 1.3.6.1.4.1.8886.1.9.3.2 | |||
| GraisecomOpticalMIBMonGroup | 1.3.6.1.4.1.8886.1.9.3.2.1 | |||
group · current A mandatory object that provides monitoring of optical characteristics. | ||||
| GraisecomOpticalMIBThresholdGroup | 1.3.6.1.4.1.8886.1.9.3.2.2 | |||
group · current A collection of objects that support thresholds on optical parameters and provide status information when the thresholds are exceeded . | ||||
| GraisecomOpticalMIBPMGroup | 1.3.6.1.4.1.8886.1.9.3.2.3 | |||
group · current A collection of objects that provide optical performance monitoring data for 15 minute and 24 hour intervals. | ||||
| GraisecomOpticalMIBNotifyEnableGroup | 1.3.6.1.4.1.8886.1.9.3.2.4 | |||
group · current An object to control the generation of notifications.
| ||||
| GraisecomOpticalMIBNotifGroup | 1.3.6.1.4.1.8886.1.9.3.2.5 | |||
group · current A notification generated when a threshold on an optical parameter is exceeded or cleared. | ||||
Textual conventions
OpticalPMPeriodINTEGERfifteenMin(1)twentyFourHour(2)This value indicates the time period over which performance monitoring data has been collected.
OpticalParameterTypeINTEGERbiasCurrent(3)receivedPower(5)supplyVoltage(2)temperature(1)txOutputPower(4)This value indicates the optical parameter that is being monitored. Valid values are - temperature(1) supplyVoltage(2) biasCurrent(3) txOutputPower(4) receivedPower(5)
OpticalParameterValueInteger32 (-1000000..65535)The value of the optical parameter that is being monitored. The range of values varies depending on the type of optical parameter being monitored, as identified by a corresponding object with syntax OpticalParameterType. When the optical parameter being monitored is 'temperature', the supported range is from -32768 to 32768, in units of 1/256 degrees centigrade. Example: A value of 6016 represents a temperature reading of 23.5 degrees C. When the optical parameter being monitored is 'supplyVoltage', the supported range is from 0 to 65535, in units of 1/10 millivolts. Example: A value of 55000 represents a supplyVoltage reading of 5.5 V. When the optical parameter being monitored is 'biasCurrent', the supported range is from 0 to 65535, in units of 1/500 microamperes. Example: A value of 500 represents a bias current reading of 1 microamperes. When the optical parameter being monitored is 'txOutputPower', the supported range is from 0 to 65535, in units of 1/10000 mW ..and express in units of dBm¡£ Example: A value of 60000 represents a txOutputPower reading of 7.78 dBm. When the optical parameter being monitored is 'receivedPower', the supported range is from 0 to 65535, in units of 1/10000 mW ..and express in units of dBm¡£ Example: A value of 60000 represents a receivedPower reading of 7.78 dBm.
Traps / Notifications
- raisecomOpticalMonParameterStatus