RAISECOM-FANMONITOR-MIB
Beijing Raisecom Scientific & Technology Development Co., Ltd.Configuration of fanMonitor object.
snmptranslate -m RAISECOM-FANMONITOR-MIB -Tpsnmpwalk -v2c -c <community> -m RAISECOM-FANMONITOR-MIB <host> 1.3.6.1.4.1.8886.1.1.5Imports
| RAISECOM-SYSTEM-MIB | raisecomSystem |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Counter32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION, TruthValue |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IraisecomFanMonitor | 1.3.6.1.4.1.8886.1.1.5 | ||||||||||||
identity Configuration of fanMonitor object. | |||||||||||||
| NraisecomFanMonitorNotification | 1.3.6.1.4.1.8886.1.1.5.1 | ||||||||||||
| !raisecomFanSpeedNormal | 1.3.6.1.4.1.8886.1.1.5.1.1 | ||||||||||||
notification · current The trap notification occur when fan state translating from abnormal to normal. | |||||||||||||
| !raisecomFanSpeedAbnormal | 1.3.6.1.4.1.8886.1.1.5.1.2 | ||||||||||||
notification · current The trap notification occur when fan state translatingfrom normal to abnormal. | |||||||||||||
| !raisecomFanCardUp | 1.3.6.1.4.1.8886.1.1.5.1.3 | ||||||||||||
notification · current The trap notification occur when fan card state translating from down to up.
| |||||||||||||
| !raisecomFanCardDown | 1.3.6.1.4.1.8886.1.1.5.1.4 | ||||||||||||
notification · current The trap notification occur when fan card state translating from up to down.
| |||||||||||||
| NraisecomFanMonitorMibObjects | 1.3.6.1.4.1.8886.1.1.5.2 | ||||||||||||
| NraisecomFanMonitorGlobalGroup | 1.3.6.1.4.1.8886.1.1.5.2.1 | ||||||||||||
| SraisecomFanMonitorMode | 1.3.6.1.4.1.8886.1.1.5.2.1.1 | INTEGER | RW | ||||||||||
scalar · INTEGER · read-write · current An integer value that specify the current monitor mode. ENFORCE(1) means that the fan speed need to set manully; AUTO(2) means that the fan speed will ajusted autoly according to the temperature
| |||||||||||||
| SraisecomFanMonitorSpdLevel | 1.3.6.1.4.1.8886.1.1.5.2.1.2 | Unsigned32 (1..4) | RW | ||||||||||
scalar · Unsigned32 (1..4) · read-write · current Specify the speed level of fan in enforce mode. | |||||||||||||
| SraisecomFanMonitorNumber | 1.3.6.1.4.1.8886.1.1.5.2.1.3 | Unsigned32 | RO | ||||||||||
scalar · Unsigned32 · read-only · current Specify the number of fan being monitorred. | |||||||||||||
| SraisecomFanMonitorLevlNumber | 1.3.6.1.4.1.8886.1.1.5.2.1.4 | Unsigned32 | RO | ||||||||||
scalar · Unsigned32 · read-only · current Specify the total number of fan speed levels. | |||||||||||||
| SraisecomFanCardState | 1.3.6.1.4.1.8886.1.1.5.2.1.5 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current Specify the current state of fan cards. all_down(1) means that all fan cards are down; all_up(2) means that all fan cards are up; card1_up(3) means that fan card 1 is up, the others are down; card2_up(4) means that fan card 2 is up, the others are down.
| |||||||||||||
| SraisecomFanCardSerialNumber | 1.3.6.1.4.1.8886.1.1.5.2.1.6 | OCTET STRING | RO | ||||||||||
scalar · OCTET STRING · read-only · current specify the identical serial number of current fan card,this string number will be set when device leaving factory | |||||||||||||
| SraisecomFanMonitorTrapSendEnable | 1.3.6.1.4.1.8886.1.1.5.2.1.7 | INTEGER | RW | ||||||||||
scalar · INTEGER · read-write · current Specifies the status of sending trap
| |||||||||||||
| TraisecomFanMonitorStateTable | 1.3.6.1.4.1.8886.1.1.5.2.2 | NA | |||||||||||
table · not-accessible · current Fan monitor state table. | |||||||||||||
| RraisecomFanMonitorStateEntry | 1.3.6.1.4.1.8886.1.1.5.2.2.1 | NA | |||||||||||
| CraisecomFanIndex | 1.3.6.1.4.1.8886.1.1.5.2.2.1.1 | Unsigned32 | NA | ||||||||||
column · Unsigned32 · not-accessible · current Specify the sequence number of fan. | |||||||||||||
| CraisecomFanSpeedValue | 1.3.6.1.4.1.8886.1.1.5.2.2.1.2 | Unsigned32 | RO | 7440 | |||||||||
| CraisecomFanWorkState | 1.3.6.1.4.1.8886.1.1.5.2.2.1.3 | INTEGER | RO | normal(1) | |||||||||
column · INTEGER · read-only · current Specify the current state of fan normal(1) means the current fan operate normally; abnormal(2) means the current fan operate abnormally
Example values from LibreNMS test devices
| |||||||||||||
| CraisecomFanSpeedCurrentLevel | 1.3.6.1.4.1.8886.1.1.5.2.2.1.4 | Unsigned32 (1..4) | RO | ||||||||||
column · Unsigned32 (1..4) · read-only · current Specify the temperature scale border that match the speed levle, based on this scale border,the current fan speed will ajusted autoly according to the current temperature | |||||||||||||
| TraisecomFanSpeedLevelTable | 1.3.6.1.4.1.8886.1.1.5.2.3 | NA | |||||||||||
table · not-accessible · current fan speed level information table. | |||||||||||||
| RraisecomFanSpeedLevelEntry | 1.3.6.1.4.1.8886.1.1.5.2.3.1 | NA | |||||||||||
| CraisecomFanSpeedLevelIndex | 1.3.6.1.4.1.8886.1.1.5.2.3.1.1 | Unsigned32 | NA | ||||||||||
column · Unsigned32 · not-accessible · current Specify the fan speed level index. | |||||||||||||
| CraisecomFanSpeedDueValue | 1.3.6.1.4.1.8886.1.1.5.2.3.1.2 | Unsigned32 | RO | ||||||||||
column · Unsigned32 · read-only · current Specify the speed value that match the fan levle index. this value can ben get from a new or normal fan ,not an used fan ,because the used fan may be aged | |||||||||||||
| CraisecomFanSpeedTemperatureScale | 1.3.6.1.4.1.8886.1.1.5.2.3.1.3 | Unsigned32 (45..75) | RW | ||||||||||
column · Unsigned32 (45..75) · read-write · current Specify the temperature scale border that match the speed levle, based on this scale border,the current fan speed will ajusted autoly according to the current temperature | |||||||||||||
Traps / Notifications
- raisecomFanCardDown
1.3.6.1.4.1.8886.1.1.5.1.4 - raisecomFanCardUp
1.3.6.1.4.1.8886.1.1.5.1.3 - raisecomFanSpeedAbnormal
1.3.6.1.4.1.8886.1.1.5.1.2 - raisecomFanSpeedNormal
1.3.6.1.4.1.8886.1.1.5.1.1