EPPC-MIB
Phoenixtec Power Co., Ltd.snmptranslate -m EPPC-MIB -Tpsnmpwalk -v2c -c <community> -m EPPC-MIB <host> 1.3.6.1.4.1.935Imports
| RFC1155-SMI | Counter32 |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
| UPS-MIB | NonNegativeInteger, PositiveInteger |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Nppc | 1.3.6.1.4.1.935 | ||||||||||||
| Ndevice | 1.3.6.1.4.1.935.10 | ||||||||||||
| NupsAgent | 1.3.6.1.4.1.935.10.1 | ||||||||||||
| NupsE | 1.3.6.1.4.1.935.10.1.1 | ||||||||||||
| NupsEIdentity | 1.3.6.1.4.1.935.10.1.1.1 | ||||||||||||
| SupsEIdentityManufacturer | 1.3.6.1.4.1.935.10.1.1.1.1 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · mandatory The name of the UPS manufacturer. | |||||||||||||
| SupsEIdentityModel | 1.3.6.1.4.1.935.10.1.1.1.2 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory The UPS Model designation. | |||||||||||||
| SupsEIdentityUPSFirmwareVerison | 1.3.6.1.4.1.935.10.1.1.1.3 | DisplayString (SIZE (0..31)) | RO | mandatory | 05616-0600 | ||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · mandatory The UPS firmware/software version(s). Example values from LibreNMS test devices
| |||||||||||||
| SupsEIndentityUPSSerialNumber | 1.3.6.1.4.1.935.10.1.1.1.4 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · mandatory optional. Most UPS don't supply the value of UPS serial No. | |||||||||||||
| SupsEIdentityDescription | 1.3.6.1.4.1.935.10.1.1.1.5 | DisplayString (SIZE (0..63)) | RW | mandatory | |||||||||
scalar · DisplayString (SIZE (0..63)) · read-write · mandatory A string to identify the UPS. This object should be set by the administrator. | |||||||||||||
| SupsEIdentityAgentSoftwareVerison | 1.3.6.1.4.1.935.10.1.1.1.6 | DisplayString (SIZE (0..31)) | RO | mandatory | 3.1.0.0 | ||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · mandatory The Network Management Card software/firmware version. This variable may or may not have the same value as upsEIdentGroupUPSSoftwareVersion in some implementations. Example values from LibreNMS test devices
| |||||||||||||
| SupsEIdentityAttachedDevices | 1.3.6.1.4.1.935.10.1.1.1.7 | DisplayString (SIZE (0..63)) | RW | mandatory | |||||||||
scalar · DisplayString (SIZE (0..63)) · read-write · mandatory A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator | |||||||||||||
| NupsESystemSummary | 1.3.6.1.4.1.935.10.1.1.2 | ||||||||||||
| SupsESystemStatus | 1.3.6.1.4.1.935.10.1.1.2.1 | INTEGER | RO | mandatory | line(4) | ||||||||
scalar · INTEGER · read-only · mandatory The indication of UPS system status.
Example values from LibreNMS test devices
| |||||||||||||
| SupsESystemTemperature | 1.3.6.1.4.1.935.10.1.1.2.2 | INTEGER | RO | mandatory | 308 | ||||||||
scalar · INTEGER · read-only · mandatory The temperature of UPS presented in 0.1 degree. Example values from LibreNMS test devices
| |||||||||||||
| SupsESystemWarningCode | 1.3.6.1.4.1.935.10.1.1.2.3 | DisplayString (SIZE (0..15)) | RO | mandatory | |||||||||
scalar · DisplayString (SIZE (0..15)) · read-only · mandatory The warning code of UPS. Please refer the warning table of 'Q6' for details. | |||||||||||||
| SupsESystemFaultCode | 1.3.6.1.4.1.935.10.1.1.2.4 | DisplayString (SIZE (0..15)) | RO | mandatory | |||||||||
scalar · DisplayString (SIZE (0..15)) · read-only · mandatory The fault code of UPS.Please refer the fault code of 'Q6' for details. | |||||||||||||
| SupsESystemConfigInputVoltage | 1.3.6.1.4.1.935.10.1.1.2.5 | NonNegativeInteger | RO | mandatory | |||||||||
scalar · NonNegativeInteger · read-only · mandatory The magnitude of the nominal input voltage presented in 0.1 V. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2. | |||||||||||||
| SupsESystemConfigInputFrequence | 1.3.6.1.4.1.935.10.1.1.2.6 | NonNegativeInteger | RO | mandatory | |||||||||
scalar · NonNegativeInteger · read-only · mandatory The nominal input frequency presented in 0.1 Hz. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2. | |||||||||||||
| SupsESystemConfigOutputVoltage | 1.3.6.1.4.1.935.10.1.1.2.7 | NonNegativeInteger | RO | mandatory | |||||||||
scalar · NonNegativeInteger · read-only · mandatory The magnitude of the nominal output voltage presented in 0.1V. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2 | |||||||||||||
| SupsESystemConfigOutputFrequency | 1.3.6.1.4.1.935.10.1.1.2.8 | NonNegativeInteger | RO | mandatory | |||||||||
scalar · NonNegativeInteger · read-only · mandatory The nominal output frequency presented in 0.1Hz. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2. | |||||||||||||
| SupsESystemConfigOutputVA | 1.3.6.1.4.1.935.10.1.1.2.9 | NonNegativeInteger | RO | mandatory | |||||||||
scalar · NonNegativeInteger · read-only · mandatory The magnitude of the nominal Volt-Amp rating presented in VA. | |||||||||||||
| SupsESystemConfigOutputPower | 1.3.6.1.4.1.935.10.1.1.2.10 | NonNegativeInteger | RO | mandatory | |||||||||
scalar · NonNegativeInteger · read-only · mandatory The magnitude of the nominal true power rating presented in W . | |||||||||||||
| SupsESystemConfigOutputLoadHighSetPoint | 1.3.6.1.4.1.935.10.1.1.2.11 | NonNegativeInteger | RW | mandatory | |||||||||
scalar · NonNegativeInteger · read-write · mandatory The maximum output load allowed before the load is too high for UPS operation | |||||||||||||
| SupsESystemConfigOverTemperatureSetPoint | 1.3.6.1.4.1.935.10.1.1.2.12 | NonNegativeInteger | RW | mandatory | |||||||||
scalar · NonNegativeInteger · read-write · mandatory The maximum temperature allowed before the UPS operation temperature is too high, presented in 0.1 degree. | |||||||||||||
| SupsESystemInputSourceNum | 1.3.6.1.4.1.935.10.1.1.2.13 | INTEGER | RO | mandatory | |||||||||
scalar · INTEGER · read-only · mandatory The present external source of input power. | |||||||||||||
| SupsESystemInputLineBads | 1.3.6.1.4.1.935.10.1.1.2.14 | Counter32 | RO | mandatory | |||||||||
scalar · Counter32 · read-only · mandatory The number of times the Input was out of tolerance in voltage or frequency. Its value should be initialized 0 after agent restarting. | |||||||||||||
| SupsESystemInputNumPhases | 1.3.6.1.4.1.935.10.1.1.2.15 | PositiveInteger (1..3) | RO | mandatory | |||||||||
scalar · PositiveInteger (1..3) · read-only · mandatory The number of input phase utilized is this device, serves as the table index. This value indicate the device initialized feature. | |||||||||||||
| TupsESystemInputTable | 1.3.6.1.4.1.935.10.1.1.2.16 | NA | mandatory | ||||||||||
table · not-accessible · mandatory A list of input table entries. The number of entries is given by the value of upsESystemInputNumPhase. | |||||||||||||
| RupsESystemInputEntry | 1.3.6.1.4.1.935.10.1.1.2.16.1 | NA | mandatory | ||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular input line.
| |||||||||||||
| CupsESystemInputPhase | 1.3.6.1.4.1.935.10.1.1.2.16.1.1 | PositiveInteger (1..3) | NA | mandatory | |||||||||
column · PositiveInteger (1..3) · not-accessible · mandatory The number of the phase. Serves as index for input table | |||||||||||||
| CupsESystemInputFrequency | 1.3.6.1.4.1.935.10.1.1.2.16.1.2 | NonNegativeInteger | RO | mandatory | 499 | ||||||||
column · NonNegativeInteger · read-only · mandatory The measured input frquency from the UPS meters in 0.1Hz. Example values from LibreNMS test devices
| |||||||||||||
| CupsESystemInputVoltage | 1.3.6.1.4.1.935.10.1.1.2.16.1.3 | NonNegativeInteger | RO | mandatory | 2382 | ||||||||
column · NonNegativeInteger · read-only · mandatory The measured input voltage from the UPS meters in 0.1 volts Example values from LibreNMS test devices
| |||||||||||||
| CupsESystemInputCurrent | 1.3.6.1.4.1.935.10.1.1.2.16.1.4 | NonNegativeInteger | RO | mandatory | -1 | ||||||||
column · NonNegativeInteger · read-only · mandatory The measured input mandatory from the UPS meters in 0.1 amps. Example values from LibreNMS test devices
| |||||||||||||
| CupsESystemInputWatts | 1.3.6.1.4.1.935.10.1.1.2.16.1.5 | NonNegativeInteger | RO | mandatory | -1 | ||||||||
column · NonNegativeInteger · read-only · mandatory The measured input real power in watts. Example values from LibreNMS test devices
| |||||||||||||
| SupsESystemOutputNumPhase | 1.3.6.1.4.1.935.10.1.1.2.17 | PositiveInteger (1..3) | RO | mandatory | |||||||||
scalar · PositiveInteger (1..3) · read-only · mandatory The number of metered output phases, serves as the table index. This value indicate the device initialized feature. | |||||||||||||
| TupsESystemOutputTable | 1.3.6.1.4.1.935.10.1.1.2.18 | NA | mandatory | ||||||||||
table · not-accessible · mandatory A list of output table entries. The number of entries is given by the value of upsESystemOutputNumPhase. | |||||||||||||
| RupsESystemOutputEntry | 1.3.6.1.4.1.935.10.1.1.2.18.1 | NA | mandatory | ||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular line. | |||||||||||||
| CupsESystemOutputPhase | 1.3.6.1.4.1.935.10.1.1.2.18.1.1 | PositiveInteger (1..3) | NA | mandatory | |||||||||
column · PositiveInteger (1..3) · not-accessible · mandatory The number of the phase. Serves as index for output table | |||||||||||||
| CupsESystemOutputFrequency | 1.3.6.1.4.1.935.10.1.1.2.18.1.2 | NonNegativeInteger | RO | mandatory | 499 | ||||||||
column · NonNegativeInteger · read-only · mandatory The measured output frequency from the UPS meters in 0.1Hz. Example values from LibreNMS test devices
| |||||||||||||
| CupsESystemOutputVoltage | 1.3.6.1.4.1.935.10.1.1.2.18.1.3 | NonNegativeInteger | RO | mandatory | 2300 | ||||||||
column · NonNegativeInteger · read-only · mandatory The measured output voltage from the UPS meters in 0.1 volts Example values from LibreNMS test devices
| |||||||||||||
| CupsESystemOutputCurrent | 1.3.6.1.4.1.935.10.1.1.2.18.1.4 | NonNegativeInteger | RO | mandatory | -1 | ||||||||
column · NonNegativeInteger · read-only · mandatory The measured output mandatory from the UPS meters in 0.1 amps. Example values from LibreNMS test devices
| |||||||||||||
| CupsESystemOutputWatts | 1.3.6.1.4.1.935.10.1.1.2.18.1.5 | NonNegativeInteger | RO | mandatory | -1 | ||||||||
column · NonNegativeInteger · read-only · mandatory The measured output real power in watts. Example values from LibreNMS test devices
| |||||||||||||
| CupsESystemOutputVA | 1.3.6.1.4.1.935.10.1.1.2.18.1.6 | NonNegativeInteger | RO | mandatory | -1 | ||||||||
column · NonNegativeInteger · read-only · mandatory The measured output real complex power in VA. Example values from LibreNMS test devices
| |||||||||||||
| CupsESystemOutputLoad | 1.3.6.1.4.1.935.10.1.1.2.18.1.7 | NonNegativeInteger | RO | mandatory | 27 | ||||||||
column · NonNegativeInteger · read-only · mandatory The UPS output load in percent of rated capacity. Example values from LibreNMS test devices
| |||||||||||||
| SupsESystemBypassNumPhase | 1.3.6.1.4.1.935.10.1.1.2.19 | PositiveInteger (1..3) | RO | mandatory | |||||||||
scalar · PositiveInteger (1..3) · read-only · mandatory The number of bypass phases, serves as the table index. This value indicate the device initialized feature | |||||||||||||
| TupsESystemBypassTable | 1.3.6.1.4.1.935.10.1.1.2.20 | NA | mandatory | ||||||||||
table · not-accessible · mandatory A list of bypass table entries. The number of entries is given by the value of upsESystemBypassNumPhase. | |||||||||||||
| RupsESystemBypassEntry | 1.3.6.1.4.1.935.10.1.1.2.20.1 | NA | mandatory | ||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular line. | |||||||||||||
| CupsESystemBypassPhase | 1.3.6.1.4.1.935.10.1.1.2.20.1.1 | PositiveInteger (1..3) | NA | mandatory | |||||||||
column · PositiveInteger (1..3) · not-accessible · mandatory The number of the phase. Serves as index for bypass table | |||||||||||||
| CupsESystemBypassFrequency | 1.3.6.1.4.1.935.10.1.1.2.20.1.2 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured bypass frequency from the UPS meters in 0.1 Hz. | |||||||||||||
| CupsESystemBypassVoltage | 1.3.6.1.4.1.935.10.1.1.2.20.1.3 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured bypass voltage from the UPS meters in 0.1 volts | |||||||||||||
| CupsESystemBypassCurrent | 1.3.6.1.4.1.935.10.1.1.2.20.1.4 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured bypass mandatory from the UPS meters in 0.1 amps | |||||||||||||
| CupsESystemBypassWatts | 1.3.6.1.4.1.935.10.1.1.2.20.1.5 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured input real power in watts. | |||||||||||||
| SupsESystemConfigBelowCapacityLimit | 1.3.6.1.4.1.935.10.1.1.2.21 | NonNegativeInteger | RW | mandatory | |||||||||
scalar · NonNegativeInteger · read-write · mandatory The UPS batteries capacity(%) limit for shutdown | |||||||||||||
| SupsESystemConfigBelowRemainTimeLimit | 1.3.6.1.4.1.935.10.1.1.2.22 | NonNegativeInteger | RW | mandatory | |||||||||
scalar · NonNegativeInteger · read-write · mandatory The UPS batteries backup time(minute) limit for shutdown | |||||||||||||
| NupsEBatterySystem | 1.3.6.1.4.1.935.10.1.1.3 | ||||||||||||
| SupsEBatteryStatus | 1.3.6.1.4.1.935.10.1.1.3.1 | INTEGER | RO | mandatory | batteryNormal(2) | ||||||||
scalar · INTEGER · read-only · mandatory The status of UPS battery, a value of batteryLow indicates that the battery-low status bit has been set from device. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is mandatoryly absent and the UPS is unable to sustain the output)
Example values from LibreNMS test devices
| |||||||||||||
| SupsESecondsOnBattery | 1.3.6.1.4.1.935.10.1.1.3.2 | NonNegativeInteger | RO | mandatory | |||||||||
scalar · NonNegativeInteger · read-only · mandatory If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. 0 shall be returned if the unit is not on battery power | |||||||||||||
| SupsEBatteryEstimatedMinutesRemaining | 1.3.6.1.4.1.935.10.1.1.3.3 | PositiveInteger | RO | mandatory | 600 | ||||||||
scalar · PositiveInteger · read-only · mandatory An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off. Example values from LibreNMS test devices
| |||||||||||||
| SupsEBatteryEstimatedChargeRemaining | 1.3.6.1.4.1.935.10.1.1.3.4 | Integer32 (0..100) | RO | mandatory | 100 | ||||||||
scalar · Integer32 (0..100) · read-only · mandatory An estimate of the battery charge remaining expressed as a percent of full charge Example values from LibreNMS test devices
| |||||||||||||
| SupsEPositiveBatteryVoltage | 1.3.6.1.4.1.935.10.1.1.3.5 | NonNegativeInteger | RO | mandatory | 1089 | ||||||||
scalar · NonNegativeInteger · read-only · mandatory The magnitude of the present positive battery voltage in 0.1 Volt DC Example values from LibreNMS test devices
| |||||||||||||
| SupsENegativeBatteryVoltage | 1.3.6.1.4.1.935.10.1.1.3.6 | NonNegativeInteger | RO | mandatory | -1 | ||||||||
scalar · NonNegativeInteger · read-only · mandatory The magnitude of the present negative battery voltage in 0.1 Volt DC Example values from LibreNMS test devices
| |||||||||||||
| SupsEBatteryCellNumber | 1.3.6.1.4.1.935.10.1.1.3.7 | NonNegativeInteger | RO | mandatory | |||||||||
scalar · NonNegativeInteger · read-only · mandatory This object indicate the cell number of each set. | |||||||||||||
| SupsEBatteryTemperature | 1.3.6.1.4.1.935.10.1.1.3.8 | INTEGER | RO | mandatory | -1 | ||||||||
scalar · INTEGER · read-only · mandatory The ambient temperature at or near the UPS Battery casing in 0.1 degree. Example values from LibreNMS test devices
| |||||||||||||
| SupsEBatteryLastReplacedDate | 1.3.6.1.4.1.935.10.1.1.3.9 | DisplayString (SIZE (10)) | RO | mandatory | |||||||||
scalar · DisplayString (SIZE (10)) · read-only · mandatory The date when the Batteries in this UPS were last replaced. The format should be DD/MM/YYYY. | |||||||||||||
| SupsEBatteryABMStatus | 1.3.6.1.4.1.935.10.1.1.3.10 | INTEGER | RO | mandatory | |||||||||
scalar · INTEGER · read-only · mandatory The status of ABM.
| |||||||||||||
| SupsEChargerModulesNum | 1.3.6.1.4.1.935.10.1.1.3.11 | NonNegativeInteger (0..32) | RO | mandatory | |||||||||
scalar · NonNegativeInteger (0..32) · read-only · mandatory The number of charger modules inserted to UPS systems. served as the index of the upsEChargerModulesTable. The default value 0 indicate that the UPS system don't have separate charger module. | |||||||||||||
| TupsEChargerModulesTable | 1.3.6.1.4.1.935.10.1.1.3.12 | NA | mandatory | ||||||||||
table · not-accessible · mandatory A list of charger modules entries. The number of entries is given by the value of upsEchargerModulesNum. | |||||||||||||
| RupsEChargerModulesEntry | 1.3.6.1.4.1.935.10.1.1.3.12.1 | NA | mandatory | ||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular charger module.
| |||||||||||||
| CchargerModulesNum | 1.3.6.1.4.1.935.10.1.1.3.12.1.1 | PositiveInteger (1..32) | NA | mandatory | |||||||||
column · PositiveInteger (1..32) · not-accessible · mandatory The number of charger modules. Serves as index for charger module table | |||||||||||||
| CchargerModulesAddress | 1.3.6.1.4.1.935.10.1.1.3.12.1.2 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory Charger Modules' address. | |||||||||||||
| CpositiveChargeVotlage | 1.3.6.1.4.1.935.10.1.1.3.12.1.3 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured positive charger voltage from the UPS meters in 0.1 volts | |||||||||||||
| CnegativeChargeVoltage | 1.3.6.1.4.1.935.10.1.1.3.12.1.4 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured nepositive charger voltage from the UPS meters in 0.1 volts | |||||||||||||
| CpositiveChargeCurrent | 1.3.6.1.4.1.935.10.1.1.3.12.1.5 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured positive charger mandatory from the UPS meters in in 0.1 amps. | |||||||||||||
| CnegativeChargeCurrent | 1.3.6.1.4.1.935.10.1.1.3.12.1.6 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured nepositive charger mandatory from the UPS meters in 0.1 amps. | |||||||||||||
| CchargerModulesTemperature | 1.3.6.1.4.1.935.10.1.1.3.12.1.7 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory The measured charger temperature from the UPS meters in 0.1 degree. | |||||||||||||
| CchargerModulesMode | 1.3.6.1.4.1.935.10.1.1.3.12.1.8 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory The working mode of charger modules.
| |||||||||||||
| NupsEPowerConverterSystem | 1.3.6.1.4.1.935.10.1.1.4 | ||||||||||||
| SupsEUPSModulesNum | 1.3.6.1.4.1.935.10.1.1.4.1 | NonNegativeInteger (0..32) | RO | mandatory | |||||||||
scalar · NonNegativeInteger (0..32) · read-only · mandatory The number of UPS modules inserted to UPS systems. served as the index of the upsEModulesTable. the default value 0 indicate that the UPS system do not have separate UPS module. | |||||||||||||
| TupsEModulesTable | 1.3.6.1.4.1.935.10.1.1.4.2 | NA | mandatory | ||||||||||
table · not-accessible · mandatory A list of UPS modules entries. The number of entries is given by the value of upsEModulesNum. | |||||||||||||
| RupsEModulesEntry | 1.3.6.1.4.1.935.10.1.1.4.2.1 | NA | mandatory | ||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular upsE module.
| |||||||||||||
| CupsEModulesNum | 1.3.6.1.4.1.935.10.1.1.4.2.1.1 | PositiveInteger (1..32) | NA | mandatory | |||||||||
column · PositiveInteger (1..32) · not-accessible · mandatory The number of UPS modules. Serves as index for UPS module table | |||||||||||||
| CupsEModuleAddress | 1.3.6.1.4.1.935.10.1.1.4.2.1.2 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory the address of UPS modules. | |||||||||||||
| CupsEModulePositiveBusVolt | 1.3.6.1.4.1.935.10.1.1.4.2.1.3 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured positive upsE module voltage from the UPS meters in 0.1 volts | |||||||||||||
| CupsEModuleNegativeBusVolt | 1.3.6.1.4.1.935.10.1.1.4.2.1.4 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured nepositive upsE module voltage from the UPS meters in 0.1 volts | |||||||||||||
| CupsEModuleTemperature | 1.3.6.1.4.1.935.10.1.1.4.2.1.5 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory The measured upsE module temperature from the UPS meters in 0.1 degree. | |||||||||||||
| CupsEModuleWorkingMode | 1.3.6.1.4.1.935.10.1.1.4.2.1.6 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory The working mode of UPS modules.
| |||||||||||||
| CupsEModuleOutputCurrentR | 1.3.6.1.4.1.935.10.1.1.4.2.1.7 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured upsE module output mandatory from the UPS meters in 0.1 A. | |||||||||||||
| CupsEModuleOutputWattR | 1.3.6.1.4.1.935.10.1.1.4.2.1.8 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured upsE module output watts from the UPS meters in watts. | |||||||||||||
| CupsEModuleOutputLoadR | 1.3.6.1.4.1.935.10.1.1.4.2.1.9 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory The output load of UPS modules in %. | |||||||||||||
| CupsEModuleWarningCode | 1.3.6.1.4.1.935.10.1.1.4.2.1.10 | DisplayString (SIZE (0..15)) | RO | mandatory | |||||||||
column · DisplayString (SIZE (0..15)) · read-only · mandatory The warning code of ups modules.Please refer the warning table of 'QU,XX' for details. | |||||||||||||
| CupsEModuleFaultCode | 1.3.6.1.4.1.935.10.1.1.4.2.1.11 | DisplayString (SIZE (0..15)) | RO | mandatory | |||||||||
column · DisplayString (SIZE (0..15)) · read-only · mandatory The fault code of ups modules.Please refer command 'QU,XX' for details. | |||||||||||||
| CupsEModuleTrapState | 1.3.6.1.4.1.935.10.1.1.4.2.1.12 | DisplayString (SIZE (0..127)) | RO | mandatory | |||||||||
column · DisplayString (SIZE (0..127)) · read-only · mandatory the values indicate the unrestored traps. For example, after AC fail, so the value of upsETrapState should be '1'. And then the AC restore, the value of upsEModuleTrapState should change to empty. | |||||||||||||
| CupsEModuleConfigOutputVA | 1.3.6.1.4.1.935.10.1.1.4.2.1.13 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The magnitude of the nominal Volt-Amp rating presented in VA. | |||||||||||||
| CupsEModuleOutputCurrentS | 1.3.6.1.4.1.935.10.1.1.4.2.1.14 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured upsE module output mandatory from the UPS meters in 0.1 A. | |||||||||||||
| CupsEModuleOutputCurrentT | 1.3.6.1.4.1.935.10.1.1.4.2.1.15 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured upsE module output mandatory from the UPS meters in 0.1 A. | |||||||||||||
| CupsEModuleOutputWattS | 1.3.6.1.4.1.935.10.1.1.4.2.1.16 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured upsE module output watts from the UPS meters in watts. | |||||||||||||
| CupsEModuleOutputWattT | 1.3.6.1.4.1.935.10.1.1.4.2.1.17 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The measured upsE module output watts from the UPS meters in watts. | |||||||||||||
| CupsEModuleOutputLoadS | 1.3.6.1.4.1.935.10.1.1.4.2.1.18 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory The output load of UPS modules in %. | |||||||||||||
| CupsEModuleOutputLoadT | 1.3.6.1.4.1.935.10.1.1.4.2.1.19 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory The output load of UPS modules in %. | |||||||||||||
| CupsEModuleOutputVAR | 1.3.6.1.4.1.935.10.1.1.4.2.1.20 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The magnitude of the nominal Volt-Amp rating presented in VA. | |||||||||||||
| CupsEModuleOutputVAS | 1.3.6.1.4.1.935.10.1.1.4.2.1.21 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The magnitude of the nominal Volt-Amp rating presented in VA. | |||||||||||||
| CupsEModuleOutputVAT | 1.3.6.1.4.1.935.10.1.1.4.2.1.22 | NonNegativeInteger | RO | mandatory | |||||||||
column · NonNegativeInteger · read-only · mandatory The magnitude of the nominal Volt-Amp rating presented in VA. | |||||||||||||
| NupsELoadSegment | 1.3.6.1.4.1.935.10.1.1.5 | ||||||||||||
| SupsELoadSegment1OffDelay | 1.3.6.1.4.1.935.10.1.1.5.1 | INTEGER | RW | mandatory | |||||||||
scalar · INTEGER · read-write · mandatory Setting this object will shutdown the UPS Load Segment output after the indicated number of seconds, or less. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. Read this object will get countdown value of the Load Segment. | |||||||||||||
| SupsELoadSegment1OnDelay | 1.3.6.1.4.1.935.10.1.1.5.2 | INTEGER | RW | mandatory | |||||||||
scalar · INTEGER · read-write · mandatory Setting this object will start the Load segment output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. | |||||||||||||
| SupsELoadSegment1AutoOffTimer | 1.3.6.1.4.1.935.10.1.1.5.3 | INTEGER | RW | mandatory | |||||||||
scalar · INTEGER · read-write · mandatory The load segment turns automatically off after the delay while the unit operates on battery, but the shutdown is cancelled if the utility return before the delay has expired. | |||||||||||||
| SupsELoadSegment1AutoOnTimer | 1.3.6.1.4.1.935.10.1.1.5.4 | INTEGER | RW | mandatory | |||||||||
scalar · INTEGER · read-write · mandatory The load segment is automatically turned on after a selected delay if it has been shutdown due to on battery. | |||||||||||||
| SupsELoadSegment1State | 1.3.6.1.4.1.935.10.1.1.5.5 | INTEGER | RO | mandatory | |||||||||
scalar · INTEGER · read-only · mandatory Load segment output state.
| |||||||||||||
| SupsELoadSegment2OffDelay | 1.3.6.1.4.1.935.10.1.1.5.6 | INTEGER | RW | mandatory | |||||||||
scalar · INTEGER · read-write · mandatory Setting this object will shutdown the UPS Load Segment output after the indicated number of seconds, or less. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. Read this object will get countdown value of the Load Segment. | |||||||||||||
| SupsELoadSegment2OnDelay | 1.3.6.1.4.1.935.10.1.1.5.7 | INTEGER | RW | mandatory | |||||||||
scalar · INTEGER · read-write · mandatory Setting this object will start the Load segment output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. | |||||||||||||
| SupsELoadSegment2AutoOffTimer | 1.3.6.1.4.1.935.10.1.1.5.8 | INTEGER | RW | mandatory | |||||||||
scalar · INTEGER · read-write · mandatory The load segment turns automatically off after the delay while the unit operates on battery, but the shutdown is cancelled if the utility return before the delay has expired. | |||||||||||||
| SupsELoadSegment2AutoOnTimer | 1.3.6.1.4.1.935.10.1.1.5.9 | INTEGER | RW | mandatory | |||||||||
scalar · INTEGER · read-write · mandatory The load segment is automatically turned on after a selected delay if it has been shutdown due to on battery. | |||||||||||||
| SupsELoadSegment2State | 1.3.6.1.4.1.935.10.1.1.5.10 | INTEGER | RO | mandatory | |||||||||
scalar · INTEGER · read-only · mandatory Load segment output state.
| |||||||||||||
| NupsEEnvironment | 1.3.6.1.4.1.935.10.1.1.6 | ||||||||||||
| NupsEEnvironmentTemperature | 1.3.6.1.4.1.935.10.1.1.6.1 | ||||||||||||
| SupsEEnvironmentCurrentTemperature | 1.3.6.1.4.1.935.10.1.1.6.1.1 | INTEGER | RO | mandatory | -1 | ||||||||
scalar · INTEGER · read-only · mandatory The measurement of temperature sensor, in 0.1 degree Example values from LibreNMS test devices
| |||||||||||||
| SupsEEnvironmentTemperatureHighSetPoint | 1.3.6.1.4.1.935.10.1.1.6.1.2 | INTEGER | RW | mandatory | 500 | ||||||||
scalar · INTEGER · read-write · mandatory The set point for high temperature warning, in 0.1 degrees. This value must be greater than upsEEnvironmentTemperatureLowSetPoint, and the least significant digit must be zero. Example values from LibreNMS test devices
| |||||||||||||
| SupsEEnvironmentTemperatureHighStatus | 1.3.6.1.4.1.935.10.1.1.6.1.3 | INTEGER | RW | mandatory | disable(2) | ||||||||
scalar · INTEGER · read-write · mandatory To enable/disable high set point check with sensor temperature.
Example values from LibreNMS test devices
| |||||||||||||
| SupsEEnvironmentTemperatureLowSetPoint | 1.3.6.1.4.1.935.10.1.1.6.1.4 | INTEGER | RW | mandatory | 150 | ||||||||
scalar · INTEGER · read-write · mandatory The set point for low temperature warning, in 0.1 degrees. This value must be less than upsEEnvironmentTemperatureHighSetPoint, and the least significant digit must be zero. Example values from LibreNMS test devices
| |||||||||||||
| SupsEEnvironmentTemperatureLowStatus | 1.3.6.1.4.1.935.10.1.1.6.1.5 | INTEGER | RW | mandatory | disable(2) | ||||||||
scalar · INTEGER · read-write · mandatory To enable/disable low set point check with sensor temperature.
Example values from LibreNMS test devices
| |||||||||||||
| SupsEEnvironmentTemperatureOffset | 1.3.6.1.4.1.935.10.1.1.6.1.6 | INTEGER | RW | mandatory | 0 | ||||||||
scalar · INTEGER · read-write · mandatory The offset to calibrate temperature of EMD, in 0.1 degrees Example values from LibreNMS test devices
| |||||||||||||
| NupsEEnvironmentHumidity | 1.3.6.1.4.1.935.10.1.1.6.2 | ||||||||||||
| SupsEEnvironmentCurrentHumidity | 1.3.6.1.4.1.935.10.1.1.6.2.1 | INTEGER | RO | mandatory | -1 | ||||||||
scalar · INTEGER · read-only · mandatory The measurement of sensor humidity present in %. Example values from LibreNMS test devices
| |||||||||||||
| SupsEEnvironmentHumidityHighSetPoint | 1.3.6.1.4.1.935.10.1.1.6.2.2 | INTEGER | RW | mandatory | 90 | ||||||||
scalar · INTEGER · read-write · mandatory The set point for high humidity warning, in %. This value must be greater than upsEEnvironmentHumidityLowSetPoint. Example values from LibreNMS test devices
| |||||||||||||
| SupsEEnvironmentHumidityHighStatus | 1.3.6.1.4.1.935.10.1.1.6.2.3 | INTEGER | RW | mandatory | disable(2) | ||||||||
scalar · INTEGER · read-write · mandatory To enable/disable high set point check with emd humidity.
Example values from LibreNMS test devices
| |||||||||||||
| SupsEEnvironmentHumidityLowSetPoint | 1.3.6.1.4.1.935.10.1.1.6.2.4 | INTEGER | RW | mandatory | 50 | ||||||||
scalar · INTEGER · read-write · mandatory The set point for low humidity warning, in %. This value must be less than upsEEnvironmentHumidityHighSetPoint. Example values from LibreNMS test devices
| |||||||||||||
| SupsEEnvironmentHumidityLowStatus | 1.3.6.1.4.1.935.10.1.1.6.2.5 | INTEGER | RW | mandatory | disable(2) | ||||||||
scalar · INTEGER · read-write · mandatory To enable/disable high set point check with emd humidity.
Example values from LibreNMS test devices
| |||||||||||||
| SupsEEnvironmentHumidityOffset | 1.3.6.1.4.1.935.10.1.1.6.2.6 | INTEGER | RW | mandatory | 0 | ||||||||
scalar · INTEGER · read-write · mandatory The offset to calibrate humidity of EMD, in %. Example values from LibreNMS test devices
| |||||||||||||
| SupsEEnvironmentContactsNum | 1.3.6.1.4.1.935.10.1.1.6.3 | NonNegativeInteger | RO | mandatory | |||||||||
scalar · NonNegativeInteger · read-only · mandatory The number of environment contacts, serves as the table index. | |||||||||||||
| TupsEEnvironmentContactTable | 1.3.6.1.4.1.935.10.1.1.6.4 | NA | mandatory | ||||||||||
table · not-accessible · mandatory A list of contacts table entries. The number of entries is given by the value of upsEEnvironmentContactsNum | |||||||||||||
| RupsEEnvironmentContactEntry | 1.3.6.1.4.1.935.10.1.1.6.4.1 | NA | mandatory | ||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular contact | |||||||||||||
| CupsEEnvironmentContactIndex | 1.3.6.1.4.1.935.10.1.1.6.4.1.1 | PositiveInteger | NA | mandatory | |||||||||
column · PositiveInteger · not-accessible · mandatory The number of environment contacts. Serves as index for environment contact table | |||||||||||||
| CupsEEnvironmentContactType | 1.3.6.1.4.1.935.10.1.1.6.4.1.2 | INTEGER | RW | mandatory | |||||||||
column · INTEGER · read-write · mandatory operation type
| |||||||||||||
| CupsEEnvironmentContactState | 1.3.6.1.4.1.935.10.1.1.6.4.1.3 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory The mandatory status.
| |||||||||||||
| CupsEEnvironmentContactDescription | 1.3.6.1.4.1.935.10.1.1.6.4.1.4 | DisplayString (SIZE (0..31)) | RW | mandatory | |||||||||
column · DisplayString (SIZE (0..31)) · read-write · mandatory Description of environment contact. | |||||||||||||
| NupsEBatteryTest | 1.3.6.1.4.1.935.10.1.1.7 | ||||||||||||
| SupsEBatteryTestStart | 1.3.6.1.4.1.935.10.1.1.7.1 | INTEGER | RW | mandatory | |||||||||
scalar · INTEGER · read-write · mandatory This object specify the battery test type and initiate battery test. If battTestWithTime selected, the test time is refer to upsEBatteryTestSettingTime.
| |||||||||||||
| SupsEBatteryTestSettingTime | 1.3.6.1.4.1.935.10.1.1.7.2 | NonNegativeInteger | RW | mandatory | |||||||||
scalar · NonNegativeInteger · read-write · mandatory The object specify the test time for battery test in seconds. | |||||||||||||
| SupsEBatteryTestResult | 1.3.6.1.4.1.935.10.1.1.7.3 | INTEGER | RO | mandatory | |||||||||
scalar · INTEGER · read-only · mandatory This object indicate the test result of battery.
| |||||||||||||
| SupsEBatteryTestStartTime | 1.3.6.1.4.1.935.10.1.1.7.4 | DisplayString (SIZE (19)) | RO | mandatory | |||||||||
scalar · DisplayString (SIZE (19)) · read-only · mandatory The value of the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsETestBatteryTestResult is noTestsInitiated(6), upsETestStartTime has the value 01/01/1970 00:00:00. | |||||||||||||
| SupsEBatteryTestElapsedTime | 1.3.6.1.4.1.935.10.1.1.7.5 | DisplayString (SIZE (11)) | RO | mandatory | |||||||||
scalar · DisplayString (SIZE (11)) · read-only · mandatory The amount of time in format hh:mm:ss, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is idle(1), upsTestElapsedTime has the value 00:00:00. | |||||||||||||
| TupsEBatteryTestScheduleTable | 1.3.6.1.4.1.935.10.1.1.7.6 | NA | mandatory | ||||||||||
table · not-accessible · mandatory This table describes the schedule for automatically battery test. | |||||||||||||
| RupsEBatteryTestScheduleEntry | 1.3.6.1.4.1.935.10.1.1.7.6.1 | NA | mandatory | ||||||||||
row · not-accessible · mandatory An entry containing information applicable to schedule test. | |||||||||||||
| CupsEBatteryTestScheduleIndex | 1.3.6.1.4.1.935.10.1.1.7.6.1.1 | PositiveInteger | NA | mandatory | |||||||||
column · PositiveInteger · not-accessible · mandatory The index of battery test scheduled. | |||||||||||||
| CupsEBatteryTestScheduleDay | 1.3.6.1.4.1.935.10.1.1.7.6.1.2 | INTEGER | RW | mandatory | |||||||||
column · INTEGER · read-write · mandatory The weekday or specaial day on which the UPS should start battery test.
| |||||||||||||
| CupsEBatteryTestScheduleTime | 1.3.6.1.4.1.935.10.1.1.7.6.1.3 | DisplayString (SIZE (5)) | RW | mandatory | |||||||||
column · DisplayString (SIZE (5)) · read-write · mandatory The time that the battery test will be initiated in hh:mm format. | |||||||||||||
| CupsEBatteryTestScheduleType | 1.3.6.1.4.1.935.10.1.1.7.6.1.5 | INTEGER | RW | mandatory | |||||||||
column · INTEGER · read-write · mandatory The type of battery test.
| |||||||||||||
| CupsEBatteryTestScheduleTestWithTime | 1.3.6.1.4.1.935.10.1.1.7.6.1.6 | NonNegativeInteger | RW | mandatory | |||||||||
column · NonNegativeInteger · read-write · mandatory The battery time of setting time test in seconds. | |||||||||||||
| CupsEBatteryTestScheduleSpecialDay | 1.3.6.1.4.1.935.10.1.1.7.6.1.7 | DisplayString (SIZE (10)) | RW | mandatory | |||||||||
column · DisplayString (SIZE (10)) · read-write · mandatory The special day that the battery test will be initiated in dd/mm/yyyy format. | |||||||||||||
| NupsEControl | 1.3.6.1.4.1.935.10.1.1.8 | ||||||||||||
| SupsEControlOutputOffDelay | 1.3.6.1.4.1.935.10.1.1.8.1 | NonNegativeInteger | RW | mandatory | |||||||||
scalar · NonNegativeInteger · read-write · mandatory Setting this value to other than zero will cause the UPS output to turn off after the number of seconds. | |||||||||||||
| SupsEControlOutputOnDelay | 1.3.6.1.4.1.935.10.1.1.8.2 | NonNegativeInteger | RW | mandatory | |||||||||
scalar · NonNegativeInteger · read-write · mandatory Setting this value to other than zero will cause the UPS output to turn on after the number of seconds. | |||||||||||||
| SupsEControlOutputOnOffControl | 1.3.6.1.4.1.935.10.1.1.8.3 | INTEGER | RW | mandatory | |||||||||
scalar · INTEGER · read-write · mandatory upsEOutputOff ( 1 ) indicates the shutdown sequence, upsEOutputOffCancel ( 2 ) indicates cancel the shutdown sequence, upsESleep( 3 ) indicates shutdown UPS first, then switch on.
| |||||||||||||
| TupsEShutdownEventsTable | 1.3.6.1.4.1.935.10.1.1.8.4 | NA | mandatory | ||||||||||
table · not-accessible · mandatory This table describes the parametes for shutdown process when shutdown event occurs | |||||||||||||
| RupsEShutdownEventsEntry | 1.3.6.1.4.1.935.10.1.1.8.4.1 | NA | mandatory | ||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular shutdown event line
| |||||||||||||
| CupsEShutdownEvent | 1.3.6.1.4.1.935.10.1.1.8.4.1.1 | INTEGER | NA | mandatory | |||||||||
column · INTEGER · not-accessible · mandatory The shutdown event identification
| |||||||||||||
| CupsEShutdownEventAction | 1.3.6.1.4.1.935.10.1.1.8.4.1.2 | INTEGER | RW | mandatory | |||||||||
column · INTEGER · read-write · mandatory Status of the corresponding shutdown Event.
When set to disable(), shutdown process will not start when
corresponding event occured.
| |||||||||||||
| CupsEShutdownwarningPeriodTime | 1.3.6.1.4.1.935.10.1.1.8.4.1.3 | NonNegativeInteger | RW | mandatory | |||||||||
column · NonNegativeInteger · read-write · mandatory The Delay in seconds after the occurance of the curresponding shutdown event, and warning message should be popped in this period. | |||||||||||||
| CupsEShutdownWarningPeriodInterval | 1.3.6.1.4.1.935.10.1.1.8.4.1.4 | NonNegativeInteger | RW | mandatory | |||||||||
column · NonNegativeInteger · read-write · mandatory The frequency of sending warning messages to the connected clients when the curresponding shutdown event occurs. The value is in units of seconds. | |||||||||||||
| TupsEControlWeeklyScheduleTable | 1.3.6.1.4.1.935.10.1.1.8.5 | NA | mandatory | ||||||||||
table · not-accessible · mandatory The table to schedule shutting down the ups by weekly | |||||||||||||
| RupsEControlWeeklyScheduleEntry | 1.3.6.1.4.1.935.10.1.1.8.5.1 | NA | mandatory | ||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular line | |||||||||||||
| CupsEControlWeeklyScheduleIndex | 1.3.6.1.4.1.935.10.1.1.8.5.1.1 | PositiveInteger | NA | mandatory | |||||||||
column · PositiveInteger · not-accessible · mandatory the index of schedule events. | |||||||||||||
| CupsEWeeklyScheduleShutdownDay | 1.3.6.1.4.1.935.10.1.1.8.5.1.2 | INTEGER | RW | mandatory | |||||||||
column · INTEGER · read-write · mandatory the weekday on which upsE shoud shutdown
| |||||||||||||
| CupsEWeeklyScheduleShutdownTime | 1.3.6.1.4.1.935.10.1.1.8.5.1.3 | DisplayString (SIZE (5)) | RW | mandatory | |||||||||
column · DisplayString (SIZE (5)) · read-write · mandatory The time that the process of shutting down the UPS will be initiated in hh:mm format. | |||||||||||||
| CupsEWeeklyScheduleRestartDay | 1.3.6.1.4.1.935.10.1.1.8.5.1.4 | INTEGER | RW | mandatory | |||||||||
column · INTEGER · read-write · mandatory the weekday on which the UPS should restart.
| |||||||||||||
| CupsEWeeklyScheduleRestartTime | 1.3.6.1.4.1.935.10.1.1.8.5.1.5 | DisplayString (SIZE (5)) | RW | mandatory | |||||||||
column · DisplayString (SIZE (5)) · read-write · mandatory The time the UPS will restart in hh:mm format. | |||||||||||||
| TupsEControlSpecialDayScheduleTable | 1.3.6.1.4.1.935.10.1.1.8.6 | NA | mandatory | ||||||||||
table · not-accessible · mandatory The table to schedule shutting down the ups. | |||||||||||||
| RupsEControlSpecialDayScheduleEntry | 1.3.6.1.4.1.935.10.1.1.8.6.1 | NA | mandatory | ||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular line. | |||||||||||||
| CupsEControlSpecialDayScheduleIndex | 1.3.6.1.4.1.935.10.1.1.8.6.1.1 | PositiveInteger | NA | mandatory | |||||||||
column · PositiveInteger · not-accessible · mandatory The index of special day schedule. | |||||||||||||
| CupsESpecialDayScheduleShutdownDay | 1.3.6.1.4.1.935.10.1.1.8.6.1.2 | DisplayString (SIZE (10)) | RW | mandatory | |||||||||
column · DisplayString (SIZE (10)) · read-write · mandatory The special day on which UPS should shutdown with the format of DD/MM/YYYY. | |||||||||||||
| CupsESpecialDayScheduleShutdownTime | 1.3.6.1.4.1.935.10.1.1.8.6.1.3 | DisplayString (SIZE (5)) | RW | mandatory | |||||||||
column · DisplayString (SIZE (5)) · read-write · mandatory The time that the process of shutting down the UPS will be initiated in hh:mm format. | |||||||||||||
| CupsESpecialDayScheduleRestartDay | 1.3.6.1.4.1.935.10.1.1.8.6.1.4 | DisplayString (SIZE (10)) | RW | mandatory | |||||||||
column · DisplayString (SIZE (10)) · read-write · mandatory The special day on which the UPS should restart with the format of DD/MM/YYYY. | |||||||||||||
| CupsESpecialDayScheduleRestartTime | 1.3.6.1.4.1.935.10.1.1.8.6.1.5 | DisplayString (SIZE (5)) | RW | mandatory | |||||||||
column · DisplayString (SIZE (5)) · read-write · mandatory The time the UPS will restart in hh:mm format. | |||||||||||||
| SupsESystemMasterOffDelay | 1.3.6.1.4.1.935.10.1.1.8.7 | INTEGER | RO | mandatory | |||||||||
scalar · INTEGER · read-only · mandatory The UPS output will shutdown after the indicated number of seconds, -1 indicate no action. | |||||||||||||
| SupsESystemMasterOnDelay | 1.3.6.1.4.1.935.10.1.1.8.8 | INTEGER | RO | mandatory | |||||||||
scalar · INTEGER · read-only · mandatory The UPS output will start on after the indicated number of seconds, -1 indicate no action. | |||||||||||||
| NupsETrapControl | 1.3.6.1.4.1.935.10.1.1.9 | ||||||||||||
| TupsETrapsReceiversTable | 1.3.6.1.4.1.935.10.1.1.9.1 | NA | mandatory | ||||||||||
table · not-accessible · mandatory This table list the managers'IP to send traps to. | |||||||||||||
| RupsETrapsReceiversEntry | 1.3.6.1.4.1.935.10.1.1.9.1.1 | NA | mandatory | ||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular input line. | |||||||||||||
| CupsETrapsReceiversIndex | 1.3.6.1.4.1.935.10.1.1.9.1.1.1 | PositiveInteger | NA | mandatory | |||||||||
column · PositiveInteger · not-accessible · mandatory The index to a trap receiver entry | |||||||||||||
| CupsETrapsReceiverAddress | 1.3.6.1.4.1.935.10.1.1.9.1.1.2 | DisplayString (SIZE (0..45)) | RW | mandatory | |||||||||
column · DisplayString (SIZE (0..45)) · read-write · mandatory The IP address of the manager to send a trap to. | |||||||||||||
| CupsETrapReceiverCommunityString | 1.3.6.1.4.1.935.10.1.1.9.1.1.3 | DisplayString (SIZE (0..32)) | RW | mandatory | |||||||||
column · DisplayString (SIZE (0..32)) · read-write · mandatory The community name to use in the trap when sent to the manager. | |||||||||||||
| CupsETrapType | 1.3.6.1.4.1.935.10.1.1.9.1.1.4 | INTEGER | RW | mandatory | |||||||||
column · INTEGER · read-write · mandatory The type of trap to be received by the manager.
| |||||||||||||
| CupsETrapsSeverityLevel | 1.3.6.1.4.1.935.10.1.1.9.1.1.5 | INTEGER | RW | mandatory | |||||||||
column · INTEGER · read-write · mandatory The severity level of traps to be received by this manager.
| |||||||||||||
| CupsETrapReceiverDescription | 1.3.6.1.4.1.935.10.1.1.9.1.1.6 | DisplayString (SIZE (0..63)) | RW | mandatory | |||||||||
column · DisplayString (SIZE (0..63)) · read-write · mandatory Description of trap receivers | |||||||||||||
| SupsETrapState | 1.3.6.1.4.1.935.10.1.1.9.2 | DisplayString (SIZE (0..127)) | RO | mandatory | |||||||||
scalar · DisplayString (SIZE (0..127)) · read-only · mandatory the values indicate the unrestored traps. For example, after AC fail, the agent send the trap 1(AC Fail) and trap 7(battery on) to NMS. so the value of upsETrapState should be '1,7'. And then the AC restore, the value of upsETrapState should change to empty. | |||||||||||||
| NupsETraps | 1.3.6.1.4.1.935.10.1.2 | ||||||||||||
| !upsEPowerFail | 1.3.6.1.4.1.935.10.1.2.0.1 | ||||||||||||
notification WARNING: Utility power not available. | |||||||||||||
| !upsEPowerRestored | 1.3.6.1.4.1.935.10.1.2.0.2 | ||||||||||||
notification INFORMATION: Utility power has restored. | |||||||||||||
| !upsELowBattery | 1.3.6.1.4.1.935.10.1.2.0.3 | ||||||||||||
notification SEVERE: The UPS batteries are low and will soon be exhausted. | |||||||||||||
| !upsEReturnFromLowBattery | 1.3.6.1.4.1.935.10.1.2.0.4 | ||||||||||||
notification INFORMATION: The UPS has return from a low battery condition. | |||||||||||||
| !upsEFailed | 1.3.6.1.4.1.935.10.1.2.0.5 | ||||||||||||
notification SEVERE: The UPS is not working fine. | |||||||||||||
| !upsEOk | 1.3.6.1.4.1.935.10.1.2.0.6 | ||||||||||||
notification INFORMATION: The UPS is working fine. | |||||||||||||
| !upsEOnBattery | 1.3.6.1.4.1.935.10.1.2.0.7 | ||||||||||||
notification WARNING: The UPS has switched to battery backup power. | |||||||||||||
| !upsENotOnBattery | 1.3.6.1.4.1.935.10.1.2.0.8 | ||||||||||||
notification INFORMATION: The UPS is not on battery power. | |||||||||||||
| !upsETestInProgress | 1.3.6.1.4.1.935.10.1.2.0.9 | ||||||||||||
notification INFORMATION: The testing is going on ups. | |||||||||||||
| !upsETestOver | 1.3.6.1.4.1.935.10.1.2.0.10 | ||||||||||||
notification INFORMATION: The testing of UPS is completed. | |||||||||||||
| !upsEBypassOn | 1.3.6.1.4.1.935.10.1.2.0.11 | ||||||||||||
notification INFORMATION: The UPS has enabled bypass. | |||||||||||||
| !upsEOnline | 1.3.6.1.4.1.935.10.1.2.0.12 | ||||||||||||
notification INFORMATION: The UPS is not on Bypass and return to normal status. | |||||||||||||
| !upsECommunicationLost | 1.3.6.1.4.1.935.10.1.2.0.13 | ||||||||||||
notification SEVERE: Communication to the UPS has been lost. | |||||||||||||
| !upsECommunicationEstablished | 1.3.6.1.4.1.935.10.1.2.0.14 | ||||||||||||
notification INFORMATION: Communication with the UPS has been established. | |||||||||||||
| !upsEGoingShutdown | 1.3.6.1.4.1.935.10.1.2.0.15 | ||||||||||||
notification WARNING: The UPS is going to shutdown output. | |||||||||||||
| !upsEShutdownCancelled | 1.3.6.1.4.1.935.10.1.2.0.16 | ||||||||||||
notification INFORMATION: The UPS is not going to shutdown output. | |||||||||||||
| !upsEOutlet1GoingShutdown | 1.3.6.1.4.1.935.10.1.2.0.17 | ||||||||||||
notification WARNING: The UPS is going to shutdown outlet1. | |||||||||||||
| !upsEOutlet1ShutdownCancelled | 1.3.6.1.4.1.935.10.1.2.0.18 | ||||||||||||
notification INFORMATION: The UPS is not going to shutdown outlet1. | |||||||||||||
| !upsEOutlet2GoingShutdown | 1.3.6.1.4.1.935.10.1.2.0.19 | ||||||||||||
notification WARNING: The UPS is going to shutdown outlet2. | |||||||||||||
| !upsEOutlet2ShutdownCancelled | 1.3.6.1.4.1.935.10.1.2.0.20 | ||||||||||||
notification INFORMATION: The UPS is not going to shutdown outlet2. | |||||||||||||
| !upsESleeping | 1.3.6.1.4.1.935.10.1.2.0.21 | ||||||||||||
notification INFORMATION: UPS has entered sleep mode and power to load has been cut off.
| |||||||||||||
| !upsEWokeUp | 1.3.6.1.4.1.935.10.1.2.0.22 | ||||||||||||
notification INFORMATION: The UPS woke up from sleep mode and power to load has been restored. | |||||||||||||
| !upsEOverTemperature | 1.3.6.1.4.1.935.10.1.2.0.23 | ||||||||||||
notification WARNING: The UPS temperature is over the setting limit. | |||||||||||||
| !upsENotOverTemperature | 1.3.6.1.4.1.935.10.1.2.0.24 | ||||||||||||
notification INFORMATION: The UPS temperature is not over the setting limit. | |||||||||||||
| !upsEOverLoad | 1.3.6.1.4.1.935.10.1.2.0.25 | ||||||||||||
notification WARNING: The UPS load is over the setting limit. | |||||||||||||
| !upsENotOverLoad | 1.3.6.1.4.1.935.10.1.2.0.26 | ||||||||||||
notification INFORMATION: The UPS load is not over the setting limit. | |||||||||||||
| !upsEModuleInserted | 1.3.6.1.4.1.935.10.1.2.0.27 | ||||||||||||
notification WARNING: UPS module or charger module plug-in. | |||||||||||||
| !upsEModuleRemoved | 1.3.6.1.4.1.935.10.1.2.0.28 | ||||||||||||
notification WARNING: UPS module or charger module unplugs. | |||||||||||||
| !sensorTemperatureTooHigh | 1.3.6.1.4.1.935.10.1.2.0.29 | ||||||||||||
notification WARNING: Sensor Temperature over high Set point. | |||||||||||||
| !sensorTemperatureNotHigh | 1.3.6.1.4.1.935.10.1.2.0.30 | ||||||||||||
notification INFORMATION: Sensor Temperature not over high Set point. | |||||||||||||
| !sensorTemperatureTooLow | 1.3.6.1.4.1.935.10.1.2.0.31 | ||||||||||||
notification WARNING: Sensor Temperature under low Set point. | |||||||||||||
| !sensorTemperatureNotLow | 1.3.6.1.4.1.935.10.1.2.0.32 | ||||||||||||
notification INFORMATION: Sensor Temperature not under low Set point. | |||||||||||||
| !sensorHumidityTooHigh | 1.3.6.1.4.1.935.10.1.2.0.33 | ||||||||||||
notification WARNING: Sensor Humidity over high Set point. | |||||||||||||
| !sensorHumidityNotHigh | 1.3.6.1.4.1.935.10.1.2.0.34 | ||||||||||||
notification INFORMATION: Sensor Humidity not over high Set point. | |||||||||||||
| !sensorHumidityTooLow | 1.3.6.1.4.1.935.10.1.2.0.35 | ||||||||||||
notification WARNING: Sensor Humidity under low Set point. | |||||||||||||
| !sensorHumidityNotLow | 1.3.6.1.4.1.935.10.1.2.0.36 | ||||||||||||
notification INFORMATION: Sensor Humidity not under low Set point. | |||||||||||||
| !contactAlarm1Active | 1.3.6.1.4.1.935.10.1.2.0.37 | ||||||||||||
notification WARNING: Contact Alarm-1 activated. | |||||||||||||
| !concactAlarm1Normal | 1.3.6.1.4.1.935.10.1.2.0.38 | ||||||||||||
notification INFORMATION: Contact Alarm-1 not active. | |||||||||||||
| !contactAlarm2Active | 1.3.6.1.4.1.935.10.1.2.0.39 | ||||||||||||
notification WARNING: Contact Alarm-2 activated. | |||||||||||||
| !contactAlarm2Normal | 1.3.6.1.4.1.935.10.1.2.0.40 | ||||||||||||
notification INFORMATION: Contact Alarm-2 not active. | |||||||||||||
| !upsEInternalwarning | 1.3.6.1.4.1.935.10.1.2.0.41 | ||||||||||||
notification WARNING: Internal warning. | |||||||||||||
| !upsEReturnFromInternalwarning | 1.3.6.1.4.1.935.10.1.2.0.42 | ||||||||||||
notification INFORMATION: Return from Internal warning. | |||||||||||||
| !upsEEPOActive | 1.3.6.1.4.1.935.10.1.2.0.43 | ||||||||||||
notification WARNING: EPO Active. | |||||||||||||
| !upsEReturnFromEPOActive | 1.3.6.1.4.1.935.10.1.2.0.44 | ||||||||||||
notification INFORMATION: Return from EPO Active. | |||||||||||||
| !upsEModuleUnlock | 1.3.6.1.4.1.935.10.1.2.0.45 | ||||||||||||
notification WARNING: Module Unlock. | |||||||||||||
| !upsEReturnFromModuleUnlock | 1.3.6.1.4.1.935.10.1.2.0.46 | ||||||||||||
notification INFORMATION: Return from Module Unlock. | |||||||||||||
| !upsEMain1Neutralloss | 1.3.6.1.4.1.935.10.1.2.0.47 | ||||||||||||
notification WARNING: Main 1 Neutral loss. | |||||||||||||
| !upsEReturnFromMain1Neutralloss | 1.3.6.1.4.1.935.10.1.2.0.48 | ||||||||||||
notification INFORMATION: Return from Main 1 Neutral loss. | |||||||||||||
| !upsEMain1phaseerror | 1.3.6.1.4.1.935.10.1.2.0.49 | ||||||||||||
notification WARNING: Main 1 phase error. | |||||||||||||
| !upsEReturnFromMain1phaseerror | 1.3.6.1.4.1.935.10.1.2.0.50 | ||||||||||||
notification INFORMATION: Return from Main 1 phase error. | |||||||||||||
| !upsESitefault | 1.3.6.1.4.1.935.10.1.2.0.51 | ||||||||||||
notification WARNING: Site fault. | |||||||||||||
| !upsEReturnFromSitefault | 1.3.6.1.4.1.935.10.1.2.0.52 | ||||||||||||
notification INFORMATION: Return from Site fault. | |||||||||||||
| !upsEBypassAbnormal | 1.3.6.1.4.1.935.10.1.2.0.53 | ||||||||||||
notification WARNING: Bypass Abnormal. | |||||||||||||
| !upsEReturnFromBypassAbnormal | 1.3.6.1.4.1.935.10.1.2.0.54 | ||||||||||||
notification INFORMATION: Return from Bypass Abnormal. | |||||||||||||
| !upsEBypassPhaseError | 1.3.6.1.4.1.935.10.1.2.0.55 | ||||||||||||
notification WARNING: Bypass Phase Error. | |||||||||||||
| !upsEReturnFromBypassPhaseError | 1.3.6.1.4.1.935.10.1.2.0.56 | ||||||||||||
notification INFORMATION: Return from Bypass Phase Error. | |||||||||||||
| !upsEBatteryOpen | 1.3.6.1.4.1.935.10.1.2.0.57 | ||||||||||||
notification WARNING: Battery Open. | |||||||||||||
| !upsEReturnFromBatteryOpen | 1.3.6.1.4.1.935.10.1.2.0.58 | ||||||||||||
notification INFORMATION: Return from Battery Open. | |||||||||||||
| !upsEBatteryOverCharge | 1.3.6.1.4.1.935.10.1.2.0.59 | ||||||||||||
notification WARNING: Battery Over Charge. | |||||||||||||
| !upsEReturnFromBatteryOverCharge | 1.3.6.1.4.1.935.10.1.2.0.60 | ||||||||||||
notification INFORMATION: Return from Battery Over Charge. | |||||||||||||
| !upsEBatteryReverse | 1.3.6.1.4.1.935.10.1.2.0.61 | ||||||||||||
notification WARNING: Battery Reverse. | |||||||||||||
| !upsEReturnFromBatteryReverse | 1.3.6.1.4.1.935.10.1.2.0.62 | ||||||||||||
notification INFORMATION: Return from Battery Reverse. | |||||||||||||
| !upsEOverloadforewarning | 1.3.6.1.4.1.935.10.1.2.0.63 | ||||||||||||
notification WARNING: Overload forewarning. | |||||||||||||
| !upsEReturnFromOverloadforewarning | 1.3.6.1.4.1.935.10.1.2.0.64 | ||||||||||||
notification INFORMATION: Return from Overload forewarning. | |||||||||||||
| !upsEOverloadWarning | 1.3.6.1.4.1.935.10.1.2.0.65 | ||||||||||||
notification WARNING: Overload Warning. | |||||||||||||
| !upsEReturnFromOverloadWarning | 1.3.6.1.4.1.935.10.1.2.0.66 | ||||||||||||
notification INFORMATION: Return from Overload Warning. | |||||||||||||
| !upsEFanLock | 1.3.6.1.4.1.935.10.1.2.0.67 | ||||||||||||
notification WARNING: Fan Lock. | |||||||||||||
| !upsEReturnFromFanLock | 1.3.6.1.4.1.935.10.1.2.0.68 | ||||||||||||
notification INFORMATION: Return from Fan Lock. | |||||||||||||
| !upsEMaintaincoverisopen | 1.3.6.1.4.1.935.10.1.2.0.69 | ||||||||||||
notification WARNING: Maintain cover is open. | |||||||||||||
| !upsEReturnFromMaintaincoverisopen | 1.3.6.1.4.1.935.10.1.2.0.70 | ||||||||||||
notification INFORMATION: Return from Maintain cover is open. | |||||||||||||
| !upsEChargerfault | 1.3.6.1.4.1.935.10.1.2.0.71 | ||||||||||||
notification WARNING: Charger fault. | |||||||||||||
| !upsEReturnFromChargerfault | 1.3.6.1.4.1.935.10.1.2.0.72 | ||||||||||||
notification INFORMATION: Return from Charger fault. | |||||||||||||
| !upsEModulelocationerror | 1.3.6.1.4.1.935.10.1.2.0.73 | ||||||||||||
notification WARNING: Module location error. | |||||||||||||
| !upsEReturnFromModulelocationerror | 1.3.6.1.4.1.935.10.1.2.0.74 | ||||||||||||
notification INFORMATION: Return from Module location error. | |||||||||||||
| !upsETurnonabnormal | 1.3.6.1.4.1.935.10.1.2.0.75 | ||||||||||||
notification WARNING: Turn on abnormal. | |||||||||||||
| !upsEReturnFromTurnonabnormal | 1.3.6.1.4.1.935.10.1.2.0.76 | ||||||||||||
notification INFORMATION: Return from Turn on abnormal. | |||||||||||||
| !upsERedundancyloss | 1.3.6.1.4.1.935.10.1.2.0.77 | ||||||||||||
notification WARNING: Redundancy loss. | |||||||||||||
| !upsEReturnFromRedundancyloss | 1.3.6.1.4.1.935.10.1.2.0.78 | ||||||||||||
notification INFORMATION: Return from Redundancy loss. | |||||||||||||
| !upsEHotSwapActived | 1.3.6.1.4.1.935.10.1.2.0.79 | ||||||||||||
notification WARNING: Hot Swap Active. | |||||||||||||
| !upsEReturnFromHotSwapActived | 1.3.6.1.4.1.935.10.1.2.0.80 | ||||||||||||
notification INFORMATION: Return from Hot Swap Active. | |||||||||||||
| !upsEBatteryInform | 1.3.6.1.4.1.935.10.1.2.0.81 | ||||||||||||
notification WARNING: Battery Inform. | |||||||||||||
| !upsEReturnFromBatteryInform | 1.3.6.1.4.1.935.10.1.2.0.82 | ||||||||||||
notification INFORMATION: Return from Battery Inform. | |||||||||||||
| !upsEInspectionInform | 1.3.6.1.4.1.935.10.1.2.0.83 | ||||||||||||
notification WARNING: Inspection Inform. | |||||||||||||
| !upsEReturnFromInspectionInform | 1.3.6.1.4.1.935.10.1.2.0.84 | ||||||||||||
notification INFORMATION: Return from Inspection Inform. | |||||||||||||
| !upsEGuaranteeInform | 1.3.6.1.4.1.935.10.1.2.0.85 | ||||||||||||
notification WARNING: Guarantee Inform. | |||||||||||||
| !upsEReturnFromGuaranteeInform | 1.3.6.1.4.1.935.10.1.2.0.86 | ||||||||||||
notification INFORMATION: Return from Guarantee Inform. | |||||||||||||
| !upsETemperatureLow | 1.3.6.1.4.1.935.10.1.2.0.87 | ||||||||||||
notification WARNING: Temperature Low. | |||||||||||||
| !upsEReturnFromTemperatureLow | 1.3.6.1.4.1.935.10.1.2.0.88 | ||||||||||||
notification INFORMATION: Return from Temperature Low. | |||||||||||||
| !upsETemperatureHigh | 1.3.6.1.4.1.935.10.1.2.0.89 | ||||||||||||
notification WARNING: Temperature High. | |||||||||||||
| !upsEReturnFromTemperatureHigh | 1.3.6.1.4.1.935.10.1.2.0.90 | ||||||||||||
notification INFORMATION: Return from Temperature High. | |||||||||||||
| !upsEBatteryOverTemperature | 1.3.6.1.4.1.935.10.1.2.0.91 | ||||||||||||
notification WARNING: Battery Over Temperature. | |||||||||||||
| !upsEReturnFromBatteryOverTemperature | 1.3.6.1.4.1.935.10.1.2.0.92 | ||||||||||||
notification INFORMATION: Return from Battery Over Temperature. | |||||||||||||
| !upsEFanMaintainInform | 1.3.6.1.4.1.935.10.1.2.0.93 | ||||||||||||
notification WARNING: Fan Maintain Inform. | |||||||||||||
| !upsEReturnFromFanMaintainInform | 1.3.6.1.4.1.935.10.1.2.0.94 | ||||||||||||
notification INFORMATION: Return from Fan Maintain Inform. | |||||||||||||
| !upsEBusCapacitanceMaintainInform | 1.3.6.1.4.1.935.10.1.2.0.95 | ||||||||||||
notification WARNING: Bus Capacitance Maintain Inform. | |||||||||||||
| !upsEReturnFromBusCapacitanceMaintainInform | 1.3.6.1.4.1.935.10.1.2.0.96 | ||||||||||||
notification INFORMATION: Return from Bus Capacitance Maintain Inform. | |||||||||||||
| !upsESystemOverCapacity | 1.3.6.1.4.1.935.10.1.2.0.97 | ||||||||||||
notification WARNING: System Over Capacity. | |||||||||||||
| !upsEReturnFromSystemOverCapacity | 1.3.6.1.4.1.935.10.1.2.0.98 | ||||||||||||
notification INFORMATION: Return from System Over Capacity. | |||||||||||||
| !upsEBelowCapacityLimit | 1.3.6.1.4.1.935.10.1.2.0.123 | ||||||||||||
notification SEVERE: The UPS batteries capacity is lower than setting limit. | |||||||||||||
| !upsENotBelowCapacityLimit | 1.3.6.1.4.1.935.10.1.2.0.124 | ||||||||||||
notification INFORMATION: The UPS batteries capacity is not lower than setting limit. | |||||||||||||
| !upsEBelowRemainTimeLimit | 1.3.6.1.4.1.935.10.1.2.0.125 | ||||||||||||
notification SEVERE: The UPS batteries backup time is below the setting limit. | |||||||||||||
| !upsENotBelowRemainTimeLimit | 1.3.6.1.4.1.935.10.1.2.0.126 | ||||||||||||
notification INFORMATION: The UPS batteries backup time is not below the setting limit. | |||||||||||||
| !upsELoadSegment1Off | 1.3.6.1.4.1.935.10.1.2.0.127 | ||||||||||||
notification WARNING: Load segment 1 is off. | |||||||||||||
| !upsELoadSegment1On | 1.3.6.1.4.1.935.10.1.2.0.128 | ||||||||||||
notification INFORMATION: Load segment 1 is on. | |||||||||||||
| !upsELoadSegment2Off | 1.3.6.1.4.1.935.10.1.2.0.129 | ||||||||||||
notification WARNING: Load segment 2 is off. | |||||||||||||
| !upsELoadSegment2On | 1.3.6.1.4.1.935.10.1.2.0.130 | ||||||||||||
notification INFORMATION: Load segment 2 is on. | |||||||||||||
Traps / Notifications
- concactAlarm1Normal
1.3.6.1.4.1.935.10.1.2.0.38 - contactAlarm1Active
1.3.6.1.4.1.935.10.1.2.0.37 - contactAlarm2Active
1.3.6.1.4.1.935.10.1.2.0.39 - contactAlarm2Normal
1.3.6.1.4.1.935.10.1.2.0.40 - sensorHumidityNotHigh
1.3.6.1.4.1.935.10.1.2.0.34 - sensorHumidityNotLow
1.3.6.1.4.1.935.10.1.2.0.36 - sensorHumidityTooHigh
1.3.6.1.4.1.935.10.1.2.0.33 - sensorHumidityTooLow
1.3.6.1.4.1.935.10.1.2.0.35 - sensorTemperatureNotHigh
1.3.6.1.4.1.935.10.1.2.0.30 - sensorTemperatureNotLow
1.3.6.1.4.1.935.10.1.2.0.32 - sensorTemperatureTooHigh
1.3.6.1.4.1.935.10.1.2.0.29 - sensorTemperatureTooLow
1.3.6.1.4.1.935.10.1.2.0.31 - upsEBatteryInform
1.3.6.1.4.1.935.10.1.2.0.81 - upsEBatteryOpen
1.3.6.1.4.1.935.10.1.2.0.57 - upsEBatteryOverCharge
1.3.6.1.4.1.935.10.1.2.0.59 - upsEBatteryOverTemperature
1.3.6.1.4.1.935.10.1.2.0.91 - upsEBatteryReverse
1.3.6.1.4.1.935.10.1.2.0.61 - upsEBelowCapacityLimit
1.3.6.1.4.1.935.10.1.2.0.123 - upsEBelowRemainTimeLimit
1.3.6.1.4.1.935.10.1.2.0.125 - upsEBusCapacitanceMaintainInform
1.3.6.1.4.1.935.10.1.2.0.95 - upsEBypassAbnormal
1.3.6.1.4.1.935.10.1.2.0.53 - upsEBypassOn
1.3.6.1.4.1.935.10.1.2.0.11 - upsEBypassPhaseError
1.3.6.1.4.1.935.10.1.2.0.55 - upsEChargerfault
1.3.6.1.4.1.935.10.1.2.0.71 - upsECommunicationEstablished
1.3.6.1.4.1.935.10.1.2.0.14 - upsECommunicationLost
1.3.6.1.4.1.935.10.1.2.0.13 - upsEEPOActive
1.3.6.1.4.1.935.10.1.2.0.43 - upsEFailed
1.3.6.1.4.1.935.10.1.2.0.5 - upsEFanLock
1.3.6.1.4.1.935.10.1.2.0.67 - upsEFanMaintainInform
1.3.6.1.4.1.935.10.1.2.0.93 - upsEGoingShutdown
1.3.6.1.4.1.935.10.1.2.0.15 - upsEGuaranteeInform
1.3.6.1.4.1.935.10.1.2.0.85 - upsEHotSwapActived
1.3.6.1.4.1.935.10.1.2.0.79 - upsEInspectionInform
1.3.6.1.4.1.935.10.1.2.0.83 - upsEInternalwarning
1.3.6.1.4.1.935.10.1.2.0.41 - upsELoadSegment1Off
1.3.6.1.4.1.935.10.1.2.0.127 - upsELoadSegment1On
1.3.6.1.4.1.935.10.1.2.0.128 - upsELoadSegment2Off
1.3.6.1.4.1.935.10.1.2.0.129 - upsELoadSegment2On
1.3.6.1.4.1.935.10.1.2.0.130 - upsELowBattery
1.3.6.1.4.1.935.10.1.2.0.3 - upsEMain1Neutralloss
1.3.6.1.4.1.935.10.1.2.0.47 - upsEMain1phaseerror
1.3.6.1.4.1.935.10.1.2.0.49 - upsEMaintaincoverisopen
1.3.6.1.4.1.935.10.1.2.0.69 - upsEModuleInserted
1.3.6.1.4.1.935.10.1.2.0.27 - upsEModuleRemoved
1.3.6.1.4.1.935.10.1.2.0.28 - upsEModuleUnlock
1.3.6.1.4.1.935.10.1.2.0.45 - upsEModulelocationerror
1.3.6.1.4.1.935.10.1.2.0.73 - upsENotBelowCapacityLimit
1.3.6.1.4.1.935.10.1.2.0.124 - upsENotBelowRemainTimeLimit
1.3.6.1.4.1.935.10.1.2.0.126 - upsENotOnBattery
1.3.6.1.4.1.935.10.1.2.0.8 - upsENotOverLoad
1.3.6.1.4.1.935.10.1.2.0.26 - upsENotOverTemperature
1.3.6.1.4.1.935.10.1.2.0.24 - upsEOk
1.3.6.1.4.1.935.10.1.2.0.6 - upsEOnBattery
1.3.6.1.4.1.935.10.1.2.0.7 - upsEOnline
1.3.6.1.4.1.935.10.1.2.0.12 - upsEOutlet1GoingShutdown
1.3.6.1.4.1.935.10.1.2.0.17 - upsEOutlet1ShutdownCancelled
1.3.6.1.4.1.935.10.1.2.0.18 - upsEOutlet2GoingShutdown
1.3.6.1.4.1.935.10.1.2.0.19 - upsEOutlet2ShutdownCancelled
1.3.6.1.4.1.935.10.1.2.0.20 - upsEOverLoad
1.3.6.1.4.1.935.10.1.2.0.25 - upsEOverTemperature
1.3.6.1.4.1.935.10.1.2.0.23 - upsEOverloadWarning
1.3.6.1.4.1.935.10.1.2.0.65 - upsEOverloadforewarning
1.3.6.1.4.1.935.10.1.2.0.63 - upsEPowerFail
1.3.6.1.4.1.935.10.1.2.0.1 - upsEPowerRestored
1.3.6.1.4.1.935.10.1.2.0.2 - upsERedundancyloss
1.3.6.1.4.1.935.10.1.2.0.77 - upsEReturnFromBatteryInform
1.3.6.1.4.1.935.10.1.2.0.82 - upsEReturnFromBatteryOpen
1.3.6.1.4.1.935.10.1.2.0.58 - upsEReturnFromBatteryOverCharge
1.3.6.1.4.1.935.10.1.2.0.60 - upsEReturnFromBatteryOverTemperature
1.3.6.1.4.1.935.10.1.2.0.92 - upsEReturnFromBatteryReverse
1.3.6.1.4.1.935.10.1.2.0.62 - upsEReturnFromBusCapacitanceMaintainInform
1.3.6.1.4.1.935.10.1.2.0.96 - upsEReturnFromBypassAbnormal
1.3.6.1.4.1.935.10.1.2.0.54 - upsEReturnFromBypassPhaseError
1.3.6.1.4.1.935.10.1.2.0.56 - upsEReturnFromChargerfault
1.3.6.1.4.1.935.10.1.2.0.72 - upsEReturnFromEPOActive
1.3.6.1.4.1.935.10.1.2.0.44 - upsEReturnFromFanLock
1.3.6.1.4.1.935.10.1.2.0.68 - upsEReturnFromFanMaintainInform
1.3.6.1.4.1.935.10.1.2.0.94 - upsEReturnFromGuaranteeInform
1.3.6.1.4.1.935.10.1.2.0.86 - upsEReturnFromHotSwapActived
1.3.6.1.4.1.935.10.1.2.0.80 - upsEReturnFromInspectionInform
1.3.6.1.4.1.935.10.1.2.0.84 - upsEReturnFromInternalwarning
1.3.6.1.4.1.935.10.1.2.0.42 - upsEReturnFromLowBattery
1.3.6.1.4.1.935.10.1.2.0.4 - upsEReturnFromMain1Neutralloss
1.3.6.1.4.1.935.10.1.2.0.48 - upsEReturnFromMain1phaseerror
1.3.6.1.4.1.935.10.1.2.0.50 - upsEReturnFromMaintaincoverisopen
1.3.6.1.4.1.935.10.1.2.0.70 - upsEReturnFromModuleUnlock
1.3.6.1.4.1.935.10.1.2.0.46 - upsEReturnFromModulelocationerror
1.3.6.1.4.1.935.10.1.2.0.74 - upsEReturnFromOverloadWarning
1.3.6.1.4.1.935.10.1.2.0.66 - upsEReturnFromOverloadforewarning
1.3.6.1.4.1.935.10.1.2.0.64 - upsEReturnFromRedundancyloss
1.3.6.1.4.1.935.10.1.2.0.78 - upsEReturnFromSitefault
1.3.6.1.4.1.935.10.1.2.0.52 - upsEReturnFromSystemOverCapacity
1.3.6.1.4.1.935.10.1.2.0.98 - upsEReturnFromTemperatureHigh
1.3.6.1.4.1.935.10.1.2.0.90 - upsEReturnFromTemperatureLow
1.3.6.1.4.1.935.10.1.2.0.88 - upsEReturnFromTurnonabnormal
1.3.6.1.4.1.935.10.1.2.0.76 - upsEShutdownCancelled
1.3.6.1.4.1.935.10.1.2.0.16 - upsESitefault
1.3.6.1.4.1.935.10.1.2.0.51 - upsESleeping
1.3.6.1.4.1.935.10.1.2.0.21 - upsESystemOverCapacity
1.3.6.1.4.1.935.10.1.2.0.97 - upsETemperatureHigh
1.3.6.1.4.1.935.10.1.2.0.89 - upsETemperatureLow
1.3.6.1.4.1.935.10.1.2.0.87 - upsETestInProgress
1.3.6.1.4.1.935.10.1.2.0.9 - upsETestOver
1.3.6.1.4.1.935.10.1.2.0.10 - upsETurnonabnormal
1.3.6.1.4.1.935.10.1.2.0.75 - upsEWokeUp
1.3.6.1.4.1.935.10.1.2.0.22