PERLE-MCR-MGT-MIB
Perle Systems LimitedThe private MIB module for the Perle Managed Media Converters
snmptranslate -m PERLE-MCR-MGT-MIB -Tpsnmpwalk -v2c -c <community> -m PERLE-MCR-MGT-MIB <host> 1.3.6.1.4.1.1966.21.1.1Imports
| SNMP-FRAMEWORK-MIB | SnmpEngineID |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Counter32, Counter64, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DateAndTime, DisplayString, MacAddress, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Nperle | 1.3.6.1.4.1.1966 | |||
| NproductId | 1.3.6.1.4.1.1966.20 | |||
| NmediaConverter | 1.3.6.1.4.1.1966.20.1 | |||
| NmcrMGT | 1.3.6.1.4.1.1966.20.1.1 | |||
| NproductMIB | 1.3.6.1.4.1.1966.21 | |||
| NmediaconverterMIB | 1.3.6.1.4.1.1966.21.1 | |||
| ImcrMGTMIB | 1.3.6.1.4.1.1966.21.1.1 | |||
identity The private MIB module for the Perle Managed Media Converters | ||||
| NmcrMGTMIBNotifications | 1.3.6.1.4.1.1966.21.1.1.0 | |||
| !mcrMgtModuleInserted | 1.3.6.1.4.1.1966.21.1.1.0.1 | |||
notification · current Trap being sent indicates that a management module has been inserted int the chassis. | ||||
| !mcrMgtSystemBoot | 1.3.6.1.4.1.1966.21.1.1.0.2 | |||
notification · current Trap being sent indicates that the management module's system firmware is being booted up and has completed system initialization. In some case this alert will indicate a cold start like a user resetting the management module or warm start if the module automatically resets because of a detected crash.
| ||||
| !mcrMgtReset | 1.3.6.1.4.1.1966.21.1.1.0.3 | |||
notification · current Trap being sent indicates that the management module has been manually reset via the reset button or one of the managers.
| ||||
| !mcrMgtResetFactory | 1.3.6.1.4.1.1966.21.1.1.0.4 | |||
notification · current Trap being sent indicates that the management module has been manually reset to factory by holding the reset button for 3 or more seconds, or one of the managers. This means that any files downloaded to the management module will be erase and the management configuration file is reset back to the default configuration.
| ||||
| !mcrMgtEtheLinkUp | 1.3.6.1.4.1.1966.21.1.1.0.5 | |||
notification · current Trap being sent indicates that the current link status of the Ethernet port on the management module is up.
| ||||
| !mcrMgtEtheLinkDown | 1.3.6.1.4.1.1966.21.1.1.0.6 | |||
notification · current Trap being sent indicates that the current link status of the Ethernet port on the management module is down.
| ||||
| !mcrMgtConMonDSRSigChg | 1.3.6.1.4.1.1966.21.1.1.0.7 | |||
notification · current Trap being sent indicates that monitor console DSR is configured and the status of one of these signal has changed on the console port.
| ||||
| !mcrMgtAuthFail | 1.3.6.1.4.1.1966.21.1.1.0.8 | |||
notification · current Trap being sent indicates that a user failed authentication via Telnet, SSH, WebManager, SNMP or the serial console. | ||||
| !mcrMgtAuthSuccess | 1.3.6.1.4.1.1966.21.1.1.0.9 | |||
notification · current Trap being sent indicates that a user failed authentication via Telnet, SSH, WebManager or the serial console. | ||||
| !mcrMgtDateTimeChg | 1.3.6.1.4.1.1966.21.1.1.0.10 | |||
notification · current Trap being sent indicates that the system date and/or time has been changed. | ||||
| !mcrMgtSntpServFail | 1.3.6.1.4.1.1966.21.1.1.0.11 | |||
notification · current Trap being sent indicates that SNTP is configured and the management module can not communicate with the configured SNTP server.
| ||||
| !mcrMgtSntpServRec | 1.3.6.1.4.1.1966.21.1.1.0.12 | |||
notification · current Trap being sent indicates that the SNTP is configured and the management module has recovered communications with the configured SNTP server.
| ||||
| !mcrMgtSnmpTrapHostFail | 1.3.6.1.4.1.1966.21.1.1.0.13 | |||
notification · current Trap being sent indicates that SNMP traps is and the management module can not communicate with the configured SNMP trap host. This trap will only be sent for SNMP trap hosts configured for 'Inform' type traps. | ||||
| !mcrMgtSnmpTrapHostRec | 1.3.6.1.4.1.1966.21.1.1.0.14 | |||
notification · current Trap being sent indicates that SNMP traps is and the management module has recovered communications with the configured SNMP trap host. | ||||
| !mcrMgtEmailServFail | 1.3.6.1.4.1.1966.21.1.1.0.15 | |||
notification · current Trap being sent indicates that an alert email server is configured and the management module can not communicate with the configured email server.
| ||||
| !mcrMgtEmailServRec | 1.3.6.1.4.1.1966.21.1.1.0.16 | |||
notification · current Trap being sent indicates that an alert email server is configured and the management module has recovered communications with the configured email server.
| ||||
| !mcrMgtConfSavedFlash | 1.3.6.1.4.1.1966.21.1.1.0.17 | |||
notification · current Trap being sent indicates that the configuration has been saved to flash on the management module.
| ||||
| !mcrMgtIpAddrDynChg | 1.3.6.1.4.1.1966.21.1.1.0.18 | |||
notification · current Trap being sent indicates that the system IP address has been dynamically changed.
| ||||
| !mcrMgtTftpUploadFail | 1.3.6.1.4.1.1966.21.1.1.0.19 | |||
notification · current Trap being sent indicates that an attempt to transfer a file via TFTP, off the management module to a remote host has failed. | ||||
| !mcrMgtTftpUploadSuccess | 1.3.6.1.4.1.1966.21.1.1.0.20 | |||
notification · current Trap being sent indicates that an attempt to transfer a file via TFTP, off the management module to a remote host was successful. | ||||
| !mcrMgtTftpDownloadFail | 1.3.6.1.4.1.1966.21.1.1.0.21 | |||
notification · current Trap being sent indicates that an attempt to transfer a file via TFTP, from a remote host to the management module has failed. | ||||
| !mcrMgtTftpDownloadSuccess | 1.3.6.1.4.1.1966.21.1.1.0.22 | |||
notification · current Trap being sent indicates that an attempt to transfer a file via TFTP, from a remote host to the management module was successful. | ||||
| !mcrMgtChassisMismatch | 1.3.6.1.4.1.1966.21.1.1.0.23 | |||
notification · current Trap being sent indicates that the management module has been inserted into a chassis that does not match it's Backup media converter module configuration. Backup media module configurations will be reset to factory default.
| ||||
| !mcrChassisAdd | 1.3.6.1.4.1.1966.21.1.1.0.24 | |||
notification · current Trap being sent indicates that a new chassis as been added to the chain of chassis. | ||||
| !mcrChassisRemove | 1.3.6.1.4.1.1966.21.1.1.0.25 | |||
notification · current Trap being sent indicates that that a chassis has been removed from the chain of chassis.
| ||||
| !mcrChassisReset | 1.3.6.1.4.1.1966.21.1.1.0.26 | |||
notification · current Trap being sent indicates that the chassis back-plane has been manually reset by a user managing the unit.
| ||||
| !mcrChassisTemperatureAlarm | 1.3.6.1.4.1.1966.21.1.1.0.27 | |||
notification · current Trap being sent indicates that the chassis temperature has exceeded the configured high temperature threshold temperature. | ||||
| !mcrChassisTemperatureRecover | 1.3.6.1.4.1.1966.21.1.1.0.28 | |||
notification · current Trap being sent indicates that the chassis temperature has recovered back to normal operating temperature. | ||||
| !mcrChassisSlotPoweredOn | 1.3.6.1.4.1.1966.21.1.1.0.29 | |||
notification · current Trap being sent indicates that the chassis slot has been powered off either manually or through the configured chassis slot power schedule. | ||||
| !mcrChassisSlotPoweredOff | 1.3.6.1.4.1.1966.21.1.1.0.30 | |||
notification · current Trap being sent indicates that the chassis slot has been powered on either manually or through the configured chassis slot power schedule. | ||||
| !mcrChassisFail | 1.3.6.1.4.1.1966.21.1.1.0.31 | |||
notification · current Trap being sent indicates that the management module has detected a failure condition in the chassis.
| ||||
| !mcrChassisOk | 1.3.6.1.4.1.1966.21.1.1.0.32 | |||
notification · current Trap being sent indicates that the chassis has recovered from a failure and is now operating normally.
| ||||
| !mcrPsmuInserted | 1.3.6.1.4.1.1966.21.1.1.0.33 | |||
notification · current Trap being sent indicates that a power supply has been inserted into the chassis. | ||||
| !mcrPsmuRemoved | 1.3.6.1.4.1.1966.21.1.1.0.34 | |||
notification · current Trap being sent indicates that a power supply's has been removed from the chassis. | ||||
| !mcrPsmuPsuFail | 1.3.6.1.4.1.1966.21.1.1.0.35 | |||
notification · current Trap being sent indicates that the power supply has failed it's self-test diagnostics. | ||||
| !mcrPsmuPsuOk | 1.3.6.1.4.1.1966.21.1.1.0.36 | |||
notification · current Trap being sent indicates that the power supply has passed it's self-test diagnostics. | ||||
| !mcrPsmuPsuVoltageFail | 1.3.6.1.4.1.1966.21.1.1.0.37 | |||
notification · current Trap being sent indicates that the voltage being supplied by the indicated power supply is insufficient. | ||||
| !mcrPsmuPsuVoltageOk | 1.3.6.1.4.1.1966.21.1.1.0.38 | |||
notification · current Trap being sent indicates that the voltage being supplied by the indicated power supply is now in the normal operating range. | ||||
| !mcrPsmuFanFail | 1.3.6.1.4.1.1966.21.1.1.0.39 | |||
notification · current Trap being sent indicates that the fan has failed. | ||||
| !mcrPsmuFanOk | 1.3.6.1.4.1.1966.21.1.1.0.40 | |||
notification · current Trap being sent indicates that the fan currently operating normally. | ||||
| !mcrMediaInserted | 1.3.6.1.4.1.1966.21.1.1.0.42 | |||
notification · current Trap being sent indicates that a media converter module has been inserted into the chassis. | ||||
| !mcrMediaRemoved | 1.3.6.1.4.1.1966.21.1.1.0.43 | |||
notification · current Trap being sent indicates that a media converter module has been removed from the chassis. | ||||
| !mcrMediaReset | 1.3.6.1.4.1.1966.21.1.1.0.44 | |||
notification · current Trap being sent indicates that the media converter module has been manually reset by a user managing the unit. | ||||
| !mcrMediaLostCommunication | 1.3.6.1.4.1.1966.21.1.1.0.45 | |||
notification · current Trap being sent indicates that the management module can no longer communicate with the media converter module | ||||
| !mcrMediaRecovCommunication | 1.3.6.1.4.1.1966.21.1.1.0.46 | |||
notification · current Trap being sent indicates that the management module recovered communication with a media converter module | ||||
| !mcrMediaFail | 1.3.6.1.4.1.1966.21.1.1.0.47 | |||
notification · current Trap being sent indicates that the media converter module has failed its self-test diagnostics | ||||
| !mcrMediaOk | 1.3.6.1.4.1.1966.21.1.1.0.48 | |||
notification · current Trap being sent indicates that the media converter module has passed its self-test diagnostics | ||||
| !mcrMediaLinkUp | 1.3.6.1.4.1.1966.21.1.1.0.49 | |||
notification · current Trap being sent indicates that the current link status of the Fiber or Copper port on the media converter module is up. | ||||
| !mcrMediaLinkDown | 1.3.6.1.4.1.1966.21.1.1.0.50 | |||
notification · current Trap being sent indicates that the current link status of the Fiber or Copper port on the media converter module is down. | ||||
| !mcrMediaConfUpdateFail | 1.3.6.1.4.1.1966.21.1.1.0.51 | |||
notification · current Trap being sent indicates that the configuration update on the media converter module has failed. | ||||
| !mcrMediaConfUpdateSuccess | 1.3.6.1.4.1.1966.21.1.1.0.52 | |||
notification · current Trap being sent indicates that the configuration update on the media converter module was successful. The media converter module configuration can be updated manually or automatically. | ||||
| !mcrMediaConfMismatch | 1.3.6.1.4.1.1966.21.1.1.0.53 | |||
notification · current Trap being sent indicates that a chassis slot is configured with Backup/Restore and the media converter module type configured for the slot does not match the media converter module type inserted into the slot. | ||||
| !mcrMediaConfMismatchResolv | 1.3.6.1.4.1.1966.21.1.1.0.54 | |||
notification · current Trap being sent indicates that a user has taken action to resolved media converter module configuration mismatch | ||||
| !mcrMediaFirmwareUpdateFail | 1.3.6.1.4.1.1966.21.1.1.0.55 | |||
notification · current Trap being sent indicates that an attempt to update a media converter module's firmware has Failed. | ||||
| !mcrMediaFirmwareUpdateSuccess | 1.3.6.1.4.1.1966.21.1.1.0.56 | |||
notification · current Trap being sent indicates that an attempt to update a media converter module's firmware was successful. | ||||
| !mcrSfpInserted | 1.3.6.1.4.1.1966.21.1.1.0.57 | |||
notification · current Trap being sent indicates that a SFP module has been inserted into a media converter module | ||||
| !mcrSfpRemoved | 1.3.6.1.4.1.1966.21.1.1.0.58 | |||
notification · current Trap being sent indicates that a SFP module has been removed from a media converter module | ||||
| !mcrSfpHighTempWarn | 1.3.6.1.4.1.1966.21.1.1.0.59 | |||
notification · current Trap being sent indicates that a SFP module's temperature has exceeded the high temperature warning threshold. | ||||
| !mcrSfpHighTempWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.60 | |||
notification · current Trap being sent indicates that a SFP module's temperature has recovered to normal operating level. | ||||
| !mcrSfpHighTempAlarm | 1.3.6.1.4.1.1966.21.1.1.0.61 | |||
notification · current Trap being sent indicates that a SFP module's temperature has exceeded the high temperature alarm threshold. | ||||
| !mcrSfpHighTempAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.62 | |||
notification · current Trap being sent indicates that a SFP module's temperature has recovered to normal operating level. | ||||
| !mcrSfpLowTempWarn | 1.3.6.1.4.1.1966.21.1.1.0.63 | |||
notification · current Trap being sent indicates that a SFP module's temperature has gone below the low temperature warning threshold. | ||||
| !mcrSfpLowTempWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.64 | |||
notification · current Trap being sent indicates that a SFP module's temperature has recovered to normal operating level. | ||||
| !mcrSfpLowTempAlarm | 1.3.6.1.4.1.1966.21.1.1.0.65 | |||
notification · current Trap being sent indicates that a SFP module's temperature has gone below the low temperature alarm threshold. | ||||
| !mcrSfpLowTempAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.66 | |||
notification · current Trap being sent indicates that a SFP module's temperature has recovered to normal operating level. | ||||
| !mcrSfpHighVoltWarn | 1.3.6.1.4.1.1966.21.1.1.0.67 | |||
notification · current Trap being sent indicates that a SFP module's voltage has exceeded the high voltage warning threshold. | ||||
| !mcrSfpHighVoltWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.68 | |||
notification · current Trap being sent indicates that a SFP module's voltage has recovered to normal operating level. | ||||
| !mcrSfpHighVoltAlarm | 1.3.6.1.4.1.1966.21.1.1.0.69 | |||
notification · current Trap being sent indicates that a SFP module's voltage has exceeded the high voltage alarm threshold. | ||||
| !mcrSfpHighVoltAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.70 | |||
notification · current Trap being sent indicates that a SFP module's voltage has recovered to normal operating level. | ||||
| !mcrSfpLowVoltWarn | 1.3.6.1.4.1.1966.21.1.1.0.71 | |||
notification · current Trap being sent indicates that a SFP module's voltage has gone below the low voltage warning threshold. | ||||
| !mcrSfpLowVoltWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.72 | |||
notification · current Trap being sent indicates that a SFP module's voltage has recovered to normal operating level. | ||||
| !mcrSfpLowVoltAlarm | 1.3.6.1.4.1.1966.21.1.1.0.73 | |||
notification · current Trap being sent indicates that a SFP module's voltage has gone below the low voltage alarm threshold. | ||||
| !mcrSfpLowVoltAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.74 | |||
notification · current Trap being sent indicates that a SFP module's voltage has recovered to normal operating level. | ||||
| !mcrSfpHighTxBiasWarn | 1.3.6.1.4.1.1966.21.1.1.0.75 | |||
notification · current Trap being sent indicates that a SFP module's TX Bias current has exceeded the high TX Bias current warning threshold. | ||||
| !mcrSfpHighTxBiasWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.76 | |||
notification · current Trap being sent indicates that a SFP module's TX Bias current has recovered to normal operating level. | ||||
| !mcrSfpHighTxBiasAlarm | 1.3.6.1.4.1.1966.21.1.1.0.77 | |||
notification · current Trap being sent indicates that a SFP module's TX Bias current has exceeded the high TX Bias current alarm threshold. | ||||
| !mcrSfpHighTxBiasAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.78 | |||
notification · current Trap being sent indicates that a SFP module's TX Bias current has recovered to normal operating level. | ||||
| !mcrSfpLowTxBiasWarn | 1.3.6.1.4.1.1966.21.1.1.0.79 | |||
notification · current Trap being sent indicates that a SFP module's TX Bias current has gone below the low Tx Bias current warning threshold. | ||||
| !mcrSfpLowTxBiasWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.80 | |||
notification · current Trap being sent indicates that a SFP module's TX Bias current has recovered to normal operating level. | ||||
| !mcrSfpLowTxBiasAlarm | 1.3.6.1.4.1.1966.21.1.1.0.81 | |||
notification · current Trap being sent indicates that a SFP module's TX Bias current has gone below the low Tx Bias current alarm threshold. | ||||
| !mcrSfpLowTxBiasAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.82 | |||
notification · current Trap being sent indicates that a SFP module's TX Bias current has recovered to normal operating level. | ||||
| !mcrSfpHighTxPowerWarn | 1.3.6.1.4.1.1966.21.1.1.0.83 | |||
notification · current Trap being sent indicates that a SFP module's TX power has exceeded the high TX power warning threshold. | ||||
| !mcrSfpHighTxPowerWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.84 | |||
notification · current Trap being sent indicates that a SFP module's TX power has recovered to normal operating level. | ||||
| !mcrSfpHighTxPowerAlarm | 1.3.6.1.4.1.1966.21.1.1.0.85 | |||
notification · current Trap being sent indicates that a SFP module's TX power has exceeded the high TX power alarm threshold. | ||||
| !mcrSfpHighTxPowerAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.86 | |||
notification · current Trap being sent indicates that a SFP module's TX power has recovered to normal operating level. | ||||
| !mcrSfpLowTxPowerWarn | 1.3.6.1.4.1.1966.21.1.1.0.87 | |||
notification · current Trap being sent indicates that a SFP module's TX power has gone below the low TX power warning threshold. | ||||
| !mcrSfpLowTxPowerWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.88 | |||
notification · current Trap being sent indicates that a SFP module's TX power has recovered to normal operating level. | ||||
| !mcrSfpLowTxPowerAlarm | 1.3.6.1.4.1.1966.21.1.1.0.89 | |||
notification · current Trap being sent indicates that a SFP module's TX power has gone below the low TX power alarm threshold. | ||||
| !mcrSfpLowTxPowerAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.90 | |||
notification · current Trap being sent indicates that a SFP module's TX power has recovered to normal operating level. | ||||
| !mcrSfpHighRxPowerWarn | 1.3.6.1.4.1.1966.21.1.1.0.91 | |||
notification · current Trap being sent indicates that a SFP module's RX power has exceeded the high RX power warning threshold. | ||||
| !mcrSfpHighRxPowerWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.92 | |||
notification · current Trap being sent indicates that a SFP module's RX power has recovered to normal operating level. | ||||
| !mcrSfpHighRxPowerAlarm | 1.3.6.1.4.1.1966.21.1.1.0.93 | |||
notification · current Trap being sent indicates that a SFP module's RX power has exceeded the high RX power alarm threshold. | ||||
| !mcrSfpHighRxPowerAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.94 | |||
notification · current Trap being sent indicates that a SFP module's RX power has recovered to normal operating level. | ||||
| !mcrSfpLowRxPowerWarn | 1.3.6.1.4.1.1966.21.1.1.0.95 | |||
notification · current Trap being sent indicates that a SFP module's RX power has gone below the low RX power warning threshold. | ||||
| !mcrSfpLowRxPowerWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.96 | |||
notification · current Trap being sent indicates that a SFP module's RX power has recovered to normal operating level. | ||||
| !mcrSfpLowRxPowerAlarm | 1.3.6.1.4.1.1966.21.1.1.0.97 | |||
notification · current Trap being sent indicates that a SFP module's RX power has gone below the low RX power alarm threshold. | ||||
| !mcrSfpLowRxPowerAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.98 | |||
notification · current Trap being sent indicates that a SFP module's RX power has recovered to normal operating level. | ||||
| !mcrChassisCommTempSensorFail | 1.3.6.1.4.1.1966.21.1.1.0.99 | |||
notification · current Trap being sent indicates that communication with the chassis temperature sensor has failed. The current chassis temperature reading will be unknown
| ||||
| !mcrChassisCommTempSensorRecov | 1.3.6.1.4.1.1966.21.1.1.0.100 | |||
notification · current Trap being sent indicates that communication with the chassis temperature sensor has recovered.
| ||||
| !mcrMediaDetectFail | 1.3.6.1.4.1.1966.21.1.1.0.101 | |||
notification · current Trap being sent indicates that the indicated media card is being powered down due to the detection of a hardware failure. | ||||
| !mcrMediaBadImage | 1.3.6.1.4.1.1966.21.1.1.0.102 | |||
notification · current Trap being sent indicates that the CRC of the media converter module firmware is incorrect. This can be caused if there is no image on the module or the image is corrupt. | ||||
| !mcrSfpLostComm | 1.3.6.1.4.1.1966.21.1.1.0.103 | |||
notification · current Trap being sent indicates that the media converter module's microcode can no longer communicate with the SFP module. | ||||
| !mcrSfpRecovComm | 1.3.6.1.4.1.1966.21.1.1.0.104 | |||
notification · current Trap being sent indicates that the media converter module's microcode had previously lost communication with, but has now regained communication with the SFP module. | ||||
| !mcrModuleNotSupported | 1.3.6.1.4.1.1966.21.1.1.0.105 | |||
notification · current Trap being sent indicates that the media converter module is not fully supported by the management module. Update the management module firmware to rectify this issue. | ||||
| !mcrModuleFirmwareUpdate | 1.3.6.1.4.1.1966.21.1.1.0.106 | |||
notification · current Trap being sent indicates that the media converter module firmware is being updated. | ||||
| !mcrSfpPortShutdown | 1.3.6.1.4.1.1966.21.1.1.0.107 | |||
notification · current Trap being sent indicates that the Sfp/Xfp port has been shutdown due to high temperature. | ||||
| !mcrSfpPortShutdownRecov | 1.3.6.1.4.1.1966.21.1.1.0.108 | |||
notification · current Trap being sent indicates that the Sfp/Xfp port shutdown has recovered. | ||||
| !mcrXfpHighApdBiasWarn | 1.3.6.1.4.1.1966.21.1.1.0.109 | |||
notification · current Trap being sent indicates that an XFP module's APD Bias Current has exceeded the high APD Bias warning threshold. | ||||
| !mcrXfpHighApdBiasWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.110 | |||
notification · current Trap being sent indicates that an XFP module's APD Bias Current has recovered to normal operating level. | ||||
| !mcrXfpHighApdBiasAlarm | 1.3.6.1.4.1.1966.21.1.1.0.111 | |||
notification · current Trap being sent indicates that an XFP module's APD Bias Current has exceeded the high APD Bias alarm threshold. | ||||
| !mcrXfpHighApdBiasAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.112 | |||
notification · current Trap being sent indicates that an XFP module's APD Bias Current has recovered to normal operating level. | ||||
| !mcrXfpLowApdBiasWarn | 1.3.6.1.4.1.1966.21.1.1.0.113 | |||
notification · current Trap being sent indicates that an XFP module's APD Bias Current has gone below the low APD Bias warning threshold. | ||||
| !mcrXfpLowApdBiasWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.114 | |||
notification · current Trap being sent indicates that an XFP module's APD Bias Current has recovered to normal operating level. | ||||
| !mcrXfpLowApdBiasAlarm | 1.3.6.1.4.1.1966.21.1.1.0.115 | |||
notification · current Trap being sent indicates that an XFP module's APD Bias Current has gone below the low APD Bias alarm threshold. | ||||
| !mcrXfpLowApdBiasAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.116 | |||
notification · current Trap being sent indicates that an XFP module's APD Bias Current has recovered to normal operating level. | ||||
| !mcrXfpHighTecCurrentWarn | 1.3.6.1.4.1.1966.21.1.1.0.117 | |||
notification · current Trap being sent indicates that an XFP module's TEC Current has exceeded the high TEC Current warning threshold. | ||||
| !mcrXfpHighTecCurrentWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.118 | |||
notification · current Trap being sent indicates that an XFP module's TEC Current has recovered to normal operating level. | ||||
| !mcrXfpHighTecCurrentAlarm | 1.3.6.1.4.1.1966.21.1.1.0.119 | |||
notification · current Trap being sent indicates that an XFP module's TEC Current has exceeded the high TEC Current alarm threshold. | ||||
| !mcrXfpHighTecCurrentAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.120 | |||
notification · current Trap being sent indicates that an XFP module's TEC Current has recovered to normal operating level. | ||||
| !mcrXfpLowTecCurrentWarn | 1.3.6.1.4.1.1966.21.1.1.0.121 | |||
notification · current Trap being sent indicates that an XFP module's TEC Current has gone below the low TEC Current warning threshold. | ||||
| !mcrXfpLowTecCurrentWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.122 | |||
notification · current Trap being sent indicates that an XFP module's TEC Current has recovered to normal operating level. | ||||
| !mcrXfpLowTecCurrentAlarm | 1.3.6.1.4.1.1966.21.1.1.0.123 | |||
notification · current Trap being sent indicates that an XFP module's TEC Current has gone below the low TEC Current alarm threshold. | ||||
| !mcrXfpLowTecCurrentAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.124 | |||
notification · current Trap being sent indicates that an XFP module's TEC Current has recovered to normal operating level. | ||||
| !mcrXfpHighLaserTempWarn | 1.3.6.1.4.1.1966.21.1.1.0.125 | |||
notification · current Trap being sent indicates that an XFP module's Laser Temperature has exceeded the high Laser Temperature warning threshold. | ||||
| !mcrXfpHighLaserTempWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.126 | |||
notification · current Trap being sent indicates that an XFP module's Laser Temperature has recovered to normal operating level. | ||||
| !mcrXfpHighLaserTempAlarm | 1.3.6.1.4.1.1966.21.1.1.0.127 | |||
notification · current Trap being sent indicates that an XFP module's Laser Temperature has exceeded the high Laser Temperature alarm threshold. | ||||
| !mcrXfpHighLaserTempAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.128 | |||
notification · current Trap being sent indicates that an XFP module's Laser Temperature has recovered to normal operating level. | ||||
| !mcrXfpLowLaserTempWarn | 1.3.6.1.4.1.1966.21.1.1.0.129 | |||
notification · current Trap being sent indicates that an XFP module's Laser Temperature has gone below the low Laser Temperature warning threshold. | ||||
| !mcrXfpLowLaserTempWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.130 | |||
notification · current Trap being sent indicates that an XFP module's Laser Temperature has recovered to normal operating level. | ||||
| !mcrXfpLowLaserTempAlarm | 1.3.6.1.4.1.1966.21.1.1.0.131 | |||
notification · current Trap being sent indicates that an XFP module's Laser Temperature has gone below the low Laser Temperature alarm threshold. | ||||
| !mcrXfpLowLaserTempAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.132 | |||
notification · current Trap being sent indicates that an XFP module's Laser Temperature has recovered to normal operating level. | ||||
| !mcrXfpHighLaserWavelengthWarn | 1.3.6.1.4.1.1966.21.1.1.0.133 | |||
notification · current Trap being sent indicates that an XFP module's Laser Wavelength has exceeded the high Laser Wavelength warning threshold. | ||||
| !mcrXfpHighLaserWavelengthWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.134 | |||
notification · current Trap being sent indicates that an XFP module's Laser Wavelength has recovered to normal operating level. | ||||
| !mcrXfpHighLaserWavelengthAlarm | 1.3.6.1.4.1.1966.21.1.1.0.135 | |||
notification · current Trap being sent indicates that an XFP module's Laser Wavelength has exceeded the high Laser Wavelength alarm threshold. | ||||
| !mcrXfpHighLaserWavelengthAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.136 | |||
notification · current Trap being sent indicates that an XFP module's Laser Wavelength has recovered to normal operating level. | ||||
| !mcrXfpLowLaserWavelengthWarn | 1.3.6.1.4.1.1966.21.1.1.0.137 | |||
notification · current Trap being sent indicates that an XFP module's Laser Wavelength has gone below the low Laser Wavelength warning threshold. | ||||
| !mcrXfpLowLaserWavelengthWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.138 | |||
notification · current Trap being sent indicates that an XFP module's Laser Wavelength has recovered to normal operating level. | ||||
| !mcrXfpLowLaserWavelengthAlarm | 1.3.6.1.4.1.1966.21.1.1.0.139 | |||
notification · current Trap being sent indicates that an XFP module's Laser Wavelength has gone below the low Laser Wavelength alarm threshold. | ||||
| !mcrXfpLowLaserWavelengthAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.140 | |||
notification · current Trap being sent indicates that an XFP module's Laser Wavelength has recovered to normal operating level. | ||||
| !mcrXfpHigh5VoltWarn | 1.3.6.1.4.1.1966.21.1.1.0.141 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has exceeded the high +5v supply warning threshold. | ||||
| !mcrXfpHigh5VoltWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.142 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | ||||
| !mcrXfpHigh5VoltAlarm | 1.3.6.1.4.1.1966.21.1.1.0.143 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has exceeded the high +5v supply alarm threshold. | ||||
| !mcrXfpHigh5VoltAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.144 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | ||||
| !mcrXfpLow5VoltWarn | 1.3.6.1.4.1.1966.21.1.1.0.145 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has gone below the low +5v supply warning threshold. | ||||
| !mcrXfpLow5VoltWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.146 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | ||||
| !mcrXfpLow5VoltAlarm | 1.3.6.1.4.1.1966.21.1.1.0.147 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has gone below the low +5v supply alarm threshold. | ||||
| !mcrXfpLow5VoltAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.148 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | ||||
| !mcrXfpHigh33VoltWarn | 1.3.6.1.4.1.1966.21.1.1.0.149 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has exceeded the high +3.3v supply warning threshold. | ||||
| !mcrXfpHigh33VoltWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.150 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | ||||
| !mcrXfpHigh33VoltAlarm | 1.3.6.1.4.1.1966.21.1.1.0.151 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has exceeded the high +3.3v supply alarm threshold. | ||||
| !mcrXfpHigh33VoltAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.152 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | ||||
| !mcrXfpLow33VoltWarn | 1.3.6.1.4.1.1966.21.1.1.0.153 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has gone below the low +3.3v supply warning threshold. | ||||
| !mcrXfpLow33VoltWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.154 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | ||||
| !mcrXfpLow33VoltAlarm | 1.3.6.1.4.1.1966.21.1.1.0.155 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has gone below the low +3.3v supply alarm threshold. | ||||
| !mcrXfpLow33VoltAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.156 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | ||||
| !mcrXfpHigh18VoltWarn | 1.3.6.1.4.1.1966.21.1.1.0.157 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has exceeded the high +1.8v supply warning threshold. | ||||
| !mcrXfpHigh18VoltWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.158 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | ||||
| !mcrXfpHigh18VoltAlarm | 1.3.6.1.4.1.1966.21.1.1.0.159 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has exceeded the high +1.8v supply alarm threshold. | ||||
| !mcrXfpHigh18VoltAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.160 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | ||||
| !mcrXfpLow18VoltWarn | 1.3.6.1.4.1.1966.21.1.1.0.161 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has gone below the low +1.8v supply warning threshold. | ||||
| !mcrXfpLow18VoltWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.162 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | ||||
| !mcrXfpLow18VoltAlarm | 1.3.6.1.4.1.1966.21.1.1.0.163 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has gone below the low +1.8v supply alarm threshold. | ||||
| !mcrXfpLow18VoltAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.164 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | ||||
| !mcrXfpHighM52VoltWarn | 1.3.6.1.4.1.1966.21.1.1.0.165 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has exceeded the high -5.2v supply warning threshold. | ||||
| !mcrXfpHighM52VoltWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.166 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | ||||
| !mcrXfpHighM52VoltAlarm | 1.3.6.1.4.1.1966.21.1.1.0.167 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has exceeded the high -5.2v supply alarm threshold. | ||||
| !mcrXfpHighM52VoltAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.168 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | ||||
| !mcrXfpLowM52VoltWarn | 1.3.6.1.4.1.1966.21.1.1.0.169 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has gone below the low -5.2v supply warning threshold. | ||||
| !mcrXfpLowM52VoltWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.170 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | ||||
| !mcrXfpLowM52VoltAlarm | 1.3.6.1.4.1.1966.21.1.1.0.171 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has gone below the low -5.2v supply alarm threshold. | ||||
| !mcrXfpLowM52VoltAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.172 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | ||||
| !mcrXfpHigh5VCurrentWarn | 1.3.6.1.4.1.1966.21.1.1.0.173 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply current has exceeded the high +5v supply current warning threshold. | ||||
| !mcrXfpHigh5VCurrentWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.174 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply current has recovered to normal operating level. | ||||
| !mcrXfpHigh5VCurrentAlarm | 1.3.6.1.4.1.1966.21.1.1.0.175 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply current has exceeded the high +5v supply current alarm threshold. | ||||
| !mcrXfpHigh5VCurrentAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.176 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply current has recovered to normal operating level. | ||||
| !mcrXfpLow5VCurrentWarn | 1.3.6.1.4.1.1966.21.1.1.0.177 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply current has gone below the low +5v supply current warning threshold. | ||||
| !mcrXfpLow5VCurrentWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.178 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply current has recovered to normal operating level. | ||||
| !mcrXfpLow5VCurrentAlarm | 1.3.6.1.4.1.1966.21.1.1.0.179 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply current has gone below the low +5v supply current alarm threshold. | ||||
| !mcrXfpLow5VCurrentAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.180 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply current has recovered to normal operating level. | ||||
| !mcrXfpHigh33VCurrentWarn | 1.3.6.1.4.1.1966.21.1.1.0.181 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply current has exceeded the high +3.3v supply current warning threshold. | ||||
| !mcrXfpHigh33VCurrentWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.182 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply current has recovered to normal operating level. | ||||
| !mcrXfpHigh33VCurrentAlarm | 1.3.6.1.4.1.1966.21.1.1.0.183 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply current has exceeded the high +3.3v supply current alarm threshold. | ||||
| !mcrXfpHigh33VCurrentAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.184 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply current has recovered to normal operating level. | ||||
| !mcrXfpLow33VCurrentWarn | 1.3.6.1.4.1.1966.21.1.1.0.185 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply current has gone below the low +3.3v supply current warning threshold. | ||||
| !mcrXfpLow33VCurrentWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.186 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply current has recovered to normal operating level. | ||||
| !mcrXfpLow33VCurrentAlarm | 1.3.6.1.4.1.1966.21.1.1.0.187 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply current has gone below the low +3.3v supply current alarm threshold. | ||||
| !mcrXfpLow33VCurrentAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.188 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply current has recovered to normal operating level. | ||||
| !mcrXfpHigh18VCurrentWarn | 1.3.6.1.4.1.1966.21.1.1.0.189 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply current has exceeded the high +1.8v supply current warning threshold. | ||||
| !mcrXfpHigh18VCurrentWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.190 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply current has recovered to normal operating level. | ||||
| !mcrXfpHigh18VCurrentAlarm | 1.3.6.1.4.1.1966.21.1.1.0.191 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply current has exceeded the high +1.8v supply current alarm threshold. | ||||
| !mcrXfpHigh18VCurrentAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.192 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply current has recovered to normal operating level. | ||||
| !mcrXfpLow18VCurrentWarn | 1.3.6.1.4.1.1966.21.1.1.0.193 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply current has gone below the low +1.8v supply current warning threshold. | ||||
| !mcrXfpLow18VCurrentWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.194 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply current has recovered to normal operating level. | ||||
| !mcrXfpLow18VCurrentAlarm | 1.3.6.1.4.1.1966.21.1.1.0.195 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply current has gone below the low +1.8v supply current alarm threshold. | ||||
| !mcrXfpLow18VCurrentAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.196 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply current has recovered to normal operating level. | ||||
| !mcrXfpHighM52VCurrentWarn | 1.3.6.1.4.1.1966.21.1.1.0.197 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply current has exceeded the high -5.2v supply current warning threshold. | ||||
| !mcrXfpHighM52VCurrentWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.198 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply current has recovered to normal operating level. | ||||
| !mcrXfpHighM52VCurrentAlarm | 1.3.6.1.4.1.1966.21.1.1.0.199 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply current has exceeded the high -5.2v supply current alarm threshold. | ||||
| !mcrXfpHighM52VCurrentAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.200 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply current has recovered to normal operating level. | ||||
| !mcrXfpLowM52VCurrentWarn | 1.3.6.1.4.1.1966.21.1.1.0.201 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply current has gone below the low -5.2v supply current warning threshold. | ||||
| !mcrXfpLowM52VCurrentWarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.202 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply current has recovered to normal operating level. | ||||
| !mcrXfpLowM52VCurrentAlarm | 1.3.6.1.4.1.1966.21.1.1.0.203 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply current has gone below the low -5.2v supply current alarm threshold. | ||||
| !mcrXfpLowM52VCurrentAlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.204 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply current has recovered to normal operating level. | ||||
| !mcrXfpHighVCC5Warn | 1.3.6.1.4.1.1966.21.1.1.0.205 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has exceeded the high +5v supply warning threshold. | ||||
| !mcrXfpHighVCC5WarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.206 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | ||||
| !mcrXfpHighVCC5Alarm | 1.3.6.1.4.1.1966.21.1.1.0.207 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has exceeded the high +5v supply alarm threshold. | ||||
| !mcrXfpHighVCC5AlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.208 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | ||||
| !mcrXfpLowVCC5Warn | 1.3.6.1.4.1.1966.21.1.1.0.209 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has gone below the low +5v supply warning threshold. | ||||
| !mcrXfpLowVCC5WarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.210 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | ||||
| !mcrXfpLowVCC5Alarm | 1.3.6.1.4.1.1966.21.1.1.0.211 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has gone below the low +5v supply alarm threshold. | ||||
| !mcrXfpLowVCC5AlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.212 | |||
notification · current Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | ||||
| !mcrXfpHighVCC3Warn | 1.3.6.1.4.1.1966.21.1.1.0.213 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has exceeded the high +3.3v supply warning threshold. | ||||
| !mcrXfpHighVCC3WarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.214 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | ||||
| !mcrXfpHighVCC3Alarm | 1.3.6.1.4.1.1966.21.1.1.0.215 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has exceeded the high +3.3v supply alarm threshold. | ||||
| !mcrXfpHighVCC3AlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.216 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | ||||
| !mcrXfpLowVCC3Warn | 1.3.6.1.4.1.1966.21.1.1.0.217 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has gone below the low +3.3v supply warning threshold. | ||||
| !mcrXfpLowVCC3WarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.218 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | ||||
| !mcrXfpLowVCC3Alarm | 1.3.6.1.4.1.1966.21.1.1.0.219 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has gone below the low +3.3v supply alarm threshold. | ||||
| !mcrXfpLowVCC3AlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.220 | |||
notification · current Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | ||||
| !mcrXfpHighVCC2Warn | 1.3.6.1.4.1.1966.21.1.1.0.221 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has exceeded the high +1.8v supply warning threshold. | ||||
| !mcrXfpHighVCC2WarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.222 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | ||||
| !mcrXfpHighVCC2Alarm | 1.3.6.1.4.1.1966.21.1.1.0.223 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has exceeded the high +1.8v supply alarm threshold. | ||||
| !mcrXfpHighVCC2AlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.224 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | ||||
| !mcrXfpLowVCC2Warn | 1.3.6.1.4.1.1966.21.1.1.0.225 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has gone below the low +1.8v supply warning threshold. | ||||
| !mcrXfpLowVCC2WarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.226 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | ||||
| !mcrXfpLowVCC2Alarm | 1.3.6.1.4.1.1966.21.1.1.0.227 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has gone below the low +1.8v supply alarm threshold. | ||||
| !mcrXfpLowVCC2AlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.228 | |||
notification · current Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | ||||
| !mcrXfpHighVEE5Warn | 1.3.6.1.4.1.1966.21.1.1.0.229 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has exceeded the high -5.2v supply warning threshold. | ||||
| !mcrXfpHighVEE5WarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.230 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | ||||
| !mcrXfpHighVEE5Alarm | 1.3.6.1.4.1.1966.21.1.1.0.231 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has exceeded the high -5.2v supply alarm threshold. | ||||
| !mcrXfpHighVEE5AlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.232 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | ||||
| !mcrXfpLowVEE5Warn | 1.3.6.1.4.1.1966.21.1.1.0.233 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has gone below the low -5.2v supply warning threshold. | ||||
| !mcrXfpLowVEE5WarnRecov | 1.3.6.1.4.1.1966.21.1.1.0.234 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | ||||
| !mcrXfpLowVEE5Alarm | 1.3.6.1.4.1.1966.21.1.1.0.235 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has gone below the low -5.2v supply alarm threshold. | ||||
| !mcrXfpLowVEE5AlarmRecov | 1.3.6.1.4.1.1966.21.1.1.0.236 | |||
notification · current Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | ||||
| !mcrSfpSpeedMismatch | 1.3.6.1.4.1.1966.21.1.1.0.237 | |||
notification · current Trap being sent indicates that there is a speed mismatch between the two SFP modules installed in the media converter. | ||||
| !mcrSfpSpeedMismatchRecov | 1.3.6.1.4.1.1966.21.1.1.0.238 | |||
notification · current Trap being sent indicates that the speed mismatch between the two SFP modules has recovered. | ||||
| !mcrXfpPowerExceeded | 1.3.6.1.4.1.1966.21.1.1.0.239 | |||
notification · current Trap being sent indicates that an XFP module's power requirements has exceeded card capacity. | ||||
| !mcrXfpPowerExceededRecov | 1.3.6.1.4.1.1966.21.1.1.0.240 | |||
notification · current Trap being sent indicates that the XFP excessive power alarm has recovered. | ||||
| !mcrLinkTestError | 1.3.6.1.4.1.1966.21.1.1.0.241 | |||
notification · current Trap being sent indicates that the link test running on the media converter has detected errors. | ||||
| !mcrAlarmRelayEngaged | 1.3.6.1.4.1.1966.21.1.1.0.242 | |||
notification · current Trap being sent indicates that the chassis alarm relay has engaged
| ||||
| !mcrAlarmRelayDisengaged | 1.3.6.1.4.1.1966.21.1.1.0.243 | |||
notification · current Trap being sent indicates that the chassis alarm relay has disengaged
| ||||
| !mcrBandwidthLevelUpstreamLow | 1.3.6.1.4.1.1966.21.1.1.0.244 | |||
notification · current Trap being sent indicates the media port is in a low upstream bandwidth condition. This happens when the bandwidth is below the configured threshold. | ||||
| !mcrBandwidthLevelUpstreamRecov | 1.3.6.1.4.1.1966.21.1.1.0.245 | |||
notification · current Trap being sent indicates the media port has recovered from a low upstream bandwidth condition. | ||||
| !mcrBandwidthLevelDownstreamLow | 1.3.6.1.4.1.1966.21.1.1.0.246 | |||
notification · current Trap being sent indicates the media port is in a low downstream bandwidth condition. This happens when the bandwidth is below the configured threshold. | ||||
| !mcrBandwidthLevelDownstreamRecov | 1.3.6.1.4.1.1966.21.1.1.0.247 | |||
notification · current Trap being sent indicates the media port has recovered from a low downstream bandwidth condition. | ||||
| !mcrMediaRemoteReset | 1.3.6.1.4.1.1966.21.1.1.0.248 | |||
notification · current Trap being sent indicates that the media converter module's peer has been manually reset by a user managing the unit. | ||||
| NmcrMGTMIBObjects | 1.3.6.1.4.1.1966.21.1.1.1 | |||
| NmcrChassisGroup | 1.3.6.1.4.1.1966.21.1.1.1.1 | |||
| TmcrChassisTable | 1.3.6.1.4.1.1966.21.1.1.1.1.1 | NA | ||
table · not-accessible · current Table of chassis diagnostic type information. | ||||
| RmcrChassisEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate chassis.
| ||||
| CmcrChassisIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.1 | Unsigned32 | AN | |
column · Unsigned32 · accessible-for-notify · current This object identifies the chassis number. | ||||
| CchassisModelName | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.2 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the name of the chassis model. For the 2-slot chassis, this is the product model. | ||||
| CchassisModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the chassis. | ||||
| CchassisSerialNumber | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.4 | DisplayString (SIZE (0..16)) | RW | |
column · DisplayString (SIZE (0..16)) · read-write · current This object identifies the chassis serial number. For the 2-slot chassis, this is writeable (and user-defined). For other chassis, this is read-only (and reflects the chassis' actual serial number). | ||||
| CchassisBootloaderVersion | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.5 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the chassis bootloader version. (Not applicable to 2-slot chassis.) | ||||
| CchassisFirmwareVersion | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.6 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the chassis firmware version. (Not applicable to 2-slot chassis.) | ||||
| CchassisOutStandWarnAlarms | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.7 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the number of outstanding warnings and alarms for this chassis. If this value is not zero then user intervention is needed to resolve the outstanding warnings and alarms. (Not applicable to 2-slot chassis.) | ||||
| CchassisDiagStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.8 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the chassis self-test diagnostics result. It will return zero if it passed and non-zero error code if it failed. The following are possible non-zero error codes: 1 - Firmware download required 2 - Temperature sensor not functional (Not applicable to 2-slot chassis.) | ||||
| CchassisTemperature | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.9 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the current temperature of the chassis. The temperature returned will be either Celsius or Fahrenheit based on your current regional display settings. If the temperature returned is -1 then a problem with the temperature sensor has occurred and the current temperature is unknown. (Not applicable to 2-slot chassis.) | ||||
| CchassisCfgHighTempThreshold | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.10 | Integer32 | RW | |
column · Integer32 · read-write · current This object identifies the chassis temperature high threshold. If the chassis temperature exceeds this threshold then an alert will be generated. The value read/written will be either Celsius or Fahrenheit based on your current regional display settings. The valid range for this threshold is 0 to 70 degrees Celsius or 32 to 158 degrees Fahrenheit. (Not applicable to 2-slot chassis.) | ||||
| CchassisReset | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.11 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object allows the resetting of the chassis (all modules). Reading this object always returns 0. | ||||
| CchassisCfgMgmtSlot | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.12 | Unsigned32 (1..2) | RW | |
column · Unsigned32 (1..2) · read-write · current For the 2-slot chassis, this is the configured slot index of the management module. This value only needs to be changed if the management module is physically installed in slot 2, rather than slot 1. The management module should be restarted after changing this value. | ||||
| TmcrPsmuTable | 1.3.6.1.4.1.1966.21.1.1.1.1.2 | NA | ||
table · not-accessible · current Table of PSMU (Power Supply Monitoring Unit) diagnostic type information. (Not applicable to 2-slot chassis.) | ||||
| RmcrPsmuEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate PSMU.
| ||||
| CmcrPsmuIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.2 | INTEGER | AN | |
column · INTEGER · accessible-for-notify · current This object identifies the PSMU bay as either A or B.
| ||||
| CmcrPsmuModelName | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the PSMU model. | ||||
| CmcrPsmuModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the power supply model present in the chassis | ||||
| CmcrPsmuPsuSerialNumber | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.5 | DisplayString (SIZE (0..16)) | RO | |
column · DisplayString (SIZE (0..16)) · read-only · current This object identifies the PSU serial number. | ||||
| CmcrPsmuBootloaderVersion | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.6 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the PSMU bootloader version. | ||||
| CmcrPsmuFirmwareVersion | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.7 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the PSMU firmware version. | ||||
| CmcrPsmuOutStandWarnAlarms | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.8 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the number of outstanding warnings and alarms for this chassis. If this value is not zero then user intervention is needed to resolve the outstanding warnings and alarms | ||||
| CmcrPsmuPsuStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.9 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies if the PSMU power supply unit (PSU) status.
| ||||
| CmcrPsmuPsuVoltage | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.10 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the current PSU voltage being supplied. | ||||
| CmcrPsmuPsuPowerUsage | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.11 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies power currently being supplied to the chassis, in milliwatts. A value of 0 indicate that the power supply is not in use | ||||
| CmcrPsmuFanStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the fan status.
| ||||
| CmcrPsmuFanSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.13 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the speed of the fan in RPM. | ||||
| TmcrChassisSlotTable | 1.3.6.1.4.1.1966.21.1.1.1.1.3 | NA | ||
table · not-accessible · current Table of chassis slot configuration, status and diagnostic type information. | ||||
| RmcrChassisSlotEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate slot in a chassis. | ||||
| CmcrChassisSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.2 | SlotNumber | AN | |
column · SlotNumber · accessible-for-notify · current This object identifies the chassis slot number. | ||||
| CmcrUserDefinedModuleName | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the user defined name of the module inserted in the slot. The default name is the model name of the media converter module | ||||
| CmcrModuleModelName | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the model name of the module inserted in the slot. | ||||
| CmcrUnManagedModuleSlotName | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.5 | DisplayString | RW | |
column · DisplayString · read-write · current This object identifies the user defined name for an unmanaged module inserted in the slot. Unmanaged modules include all perle C-1000, C-100, C-1110 and c-110 type modules. | ||||
| CmcrModuleSerialNumber | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.6 | DisplayString (SIZE (0..16)) | RO | |
column · DisplayString (SIZE (0..16)) · read-only · current This object identifies the serial number of the module inserted in the slot. | ||||
| CmcrModuleBootloaderVersion | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.7 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the bootloader version of the module inserted in the slot. | ||||
| CmcrModuleFirmwareVersion | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.8 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the firmware version of the module inserted in the slot. | ||||
| CmcrModuleoOutStandWarnAlarms | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.9 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the number of outstanding warnings and alarms for this module. If this value is not zero then user intervention is needed to resolve the outstanding warnings and alarms | ||||
| CmcrModuleDiagStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.10 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the module's self-test diagnostics result. It will return zero if it passed and non-zero error code if the module has failed.The following are possible non-zero error codes: 1 - Media converter module's PHY is not functional. 2 - Firmware download required | ||||
| CmcrModuleTypeInserted | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the module type inserted for this chassis slot.
| ||||
| CmcrMediaConfigBackupRestore | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.12 | INTEGER | RW | |
column · INTEGER · read-write · current This object is applicable to media converter modules only. It identifies whether the media configuration will be automatically backed up to or restored from the management card's non-volatile memory
| ||||
| CmcrMediaBackedupModuleType | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.13 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module type of the configuration that was backed up for the slot on the management card's non-volatile memory when the mcrMediaConfigBackupRestore object was enabled.
| ||||
| CmcrChassisPwrUpSlotPwrState | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.14 | OnOffValue | RW | |
column · OnOffValue · read-write · current This object identifies the default power state of the slot when the chassis is initially powered up. The current power state of the slot can be manually changed by writing to mcrCurrentPowerState object or dynamically changed via slot power schedule configuration. (Not applicable to 2-slot chassis.) | ||||
| CmcrCurrentPowerState | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.15 | OnOffValue | RW | |
column · OnOffValue · read-write · current Writing this object allows the current power state of the slot to be turned on or off. This object is not writable for management modules or the 2-slot chassis. Reading this object will return the current slot power state. | ||||
| CmcrPowerScheduleEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.16 | INTEGER | RW | |
column · INTEGER · read-write · current This object is not applicable to management modules. It identifies if power schedule is enabled for the slot. (Not applicable to 2-slot chassis.)
| ||||
| CmcrModuleReset | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.17 | INTEGER | RW | |
column · INTEGER · read-write · current This object allows you to reset the module inserted in the slot.
| ||||
| CmcrModuleResetToFactory | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.18 | INTEGER | RW | |
column · INTEGER · read-write · current This object allows you to reset to factory the module inserted in the slot.
| ||||
| CmcrModuleModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.19 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the media converter module present in the slot. | ||||
| NmcrModuleTypes | 1.3.6.1.4.1.1966.21.1.1.1.1.4 | |||
| Ncm1000Fixed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1 | |||
| Tcm1000FixedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1 | NA | ||
table · not-accessible · current Table of CM-1000 type media converter module's status type information. | ||||
| Rcm1000FixedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1000 type media converter module. | ||||
| Ccm1000SlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1000 type module is currently inserted | ||||
| Ccm1000Modelname | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the model of media converter module present in the chassis | ||||
| Ccm1000ModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the media converter module present in the chassis | ||||
| Ccm1000HwJmp5ConfigMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers.
| ||||
| Ccm1000HwSw1FiberAutoNeg | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for fiber Auto-Negotiation.
| ||||
| Ccm1000HwSw2LinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Link Mode.
| ||||
| Ccm1000HwSw3FiberFaultAlert | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Fiber Fault Alert.
| ||||
| Ccm1000HwSw4Duplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.9 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for copper duplex.
| ||||
| Ccm1000HwSw5Pause | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.10 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for copper pause (flow control).
| ||||
| Ccm1000HwSw6Loopback | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for fiber loopback mode.
| ||||
| Ccm1000FiberLinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status.
| ||||
| Ccm1000FiberConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.13 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type.
| ||||
| Ccm1000FiberAutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.14 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber auto-negotiation state.
| ||||
| Ccm1000FiberSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.15 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port speed in megabits per second.
| ||||
| Ccm1000FiberDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.16 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm1000FiberPauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.17 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm1000FiberLPRFStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.18 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber Link Partner Remote Fault status.
| ||||
| Ccm1000FiberReceiveStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.19 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the status of whether light is being received on the fiber port
| ||||
| Ccm1000FiberLoopBack | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.20 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current Media converter module's current fiber loopback mode setting. Writing to this object will change the current settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm1000CopperLinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.21 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current copper link status.
| ||||
| Ccm1000CopperConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.22 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's copper connector type.
| ||||
| Ccm1000CopperAutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.23 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current copper auto-negotiation state.
| ||||
| Ccm1000CopperSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.24 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's copper port speed in megabits per second.
| ||||
| Ccm1000CopperDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.25 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm1000CopperCrossOver | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.26 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm1000CopperPauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.27 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm1000CopperLPRFStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.28 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's copper Link Partner Remote Fault status.
| ||||
| Tcm1000ConfigTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2 | NA | ||
table · not-accessible · current Table of CM-1000 type media converter module's configuration type information. | ||||
| Rcm1000ConfigEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1000 type media converter module. | ||||
| Ccm1000ConfigSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1000 type module is currently inserted | ||||
| Ccm1000ConfigStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.3 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| Ccm1000ConfigModuleName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.4 | DisplayString (SIZE (0..63)) | RW | |
column · DisplayString (SIZE (0..63)) · read-write · current This object identifies a user configurable name for the media converter module present in the chassis. | ||||
| Ccm1000ConfigLinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm1000ConfigFiberFaultAlert | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.6 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm1000ConfigJumboPackets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.7 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the Jumbo Packet setting for the media converter module present in the chassis. | ||||
| Ccm1000ConfigFiberPortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.8 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the fiber port. | ||||
| Ccm1000ConfigFiberPortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.9 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the fiber port is enabled. | ||||
| Ccm1000ConfigFiberAutoNeg | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.10 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the wither fiber auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm1000ConfigCopperPortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.11 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the copper port. | ||||
| Ccm1000ConfigCopperPortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.12 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the fiber port is enabled. | ||||
| Ccm1000ConfigCopperDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.13 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the duplex settings for the copper port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm1000ConfigCopperPauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.14 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the copper pause (flow control) setting that is a advertised. The settings can be disabled, advertise symmetrical, advertise asymmetrical TX or advertise symmetrical and asymmetrical RX. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm1000ConfigCopperLowPower | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.15 | OnOffValue | RW | |
column · OnOffValue · read-write · current This object identifies the copper low power setting for the media converter module present in the chassis. | ||||
| Tcm1000LedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3 | NA | ||
table · not-accessible · current Table of CM-1000 type media converter module's LED status information. | ||||
| Rcm1000LedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1000 type media converter module. | ||||
| Ccm1000LedSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1000 type module is currently inserted | ||||
| Ccm1000LedPWR | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1.3 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the power (PWR) LED on the media converter module.
Possible status values are:
off(0) - No power to the module
onGreen(1) - Power being applied to module
blinking(2) - Fiber loopback enabled
| ||||
| Ccm1000LedLKF | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link copper (LKC) LED on the
media converter module.
Possible status values are:
off(0) - No fiber link
on(1) - Fiber link present
| ||||
| Ccm1000LedLKC | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link copper (LKC) LED on the
media converter module.
Possible status values are:
off(0) - No copper link
on(1) - Copper link present
| ||||
| Ncm100Fixed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2 | |||
| Tcm100FixedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1 | NA | ||
table · not-accessible · current Table of CM-100 type media converter module's configuration and status type information. | ||||
| Rcm100FixedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1000 type media converter module. | ||||
| Ccm100SlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-100 type module is currently inserted | ||||
| Ccm100ModelName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the model of media converter module present in the chassis | ||||
| Ccm100ModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the media converter module present in the chassis | ||||
| Ccm100HwJmp5ConfigMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers.
| ||||
| Ccm100HwJmp6AutoMDI | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module's hardware Auto MDIX jumper settings.
| ||||
| Ccm100HwSw1AutoNegotiation | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for fiber Auto-Negotiation.
| ||||
| Ccm100HwSw2LinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Link Mode.
| ||||
| Ccm100HwSw3FarEndFault | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.9 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Far End Fault.
| ||||
| Ccm100HwSw5Pause | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.10 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for copper pause (flow control).
| ||||
| Ccm100HwSw6Loopback | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for fiber loopback mode.
| ||||
| Ccm100FiberLinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status.
| ||||
| Ccm100FiberConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.13 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type.
| ||||
| Ccm100FiberSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.14 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port speed in megabits per second.
| ||||
| Ccm100FiberFarEndFault | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.15 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber Far End Fault status.
| ||||
| Ccm100FiberReceiveStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.16 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the status of whether light is being received on the fiber port
| ||||
| Ccm100FiberLoopBack | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.17 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm100CopperLinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.18 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current copper link status.
| ||||
| Ccm100CopperConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.19 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's copper connector type.
| ||||
| Ccm100CopperAutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.20 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current copper auto-negotiation state.
| ||||
| Ccm100CopperSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.21 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the copper port speed in megabits per second.
| ||||
| Ccm100CopperDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.22 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm100CopperCrossOver | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.23 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm100CopperPause | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.24 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated pause (flow control) setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm100CopperLPRFStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.25 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's copper Link Partner Remote Fault status.
| ||||
| Tcm100ConfigTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2 | NA | ||
table · not-accessible · current Table of CM-100 type media converter module's configuration and status type information. | ||||
| Rcm100ConfigEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1000 type media converter module. | ||||
| Ccm100ConfigSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1000 type module is currently inserted | ||||
| Ccm100ConfigStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.3 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| Ccm100ConfigModuleName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.4 | DisplayString (SIZE (0..63)) | RW | |
column · DisplayString (SIZE (0..63)) · read-write · current This object identifies a user configurable name for the media converter module present in the chassis. | ||||
| Ccm100ConfigLinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm100ConfigFiberFarEndFault | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.6 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the fiber Far End Fault setting for the media module. This setting is always enabled if Link Mode is set to linkPassthrough. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm100ConfigFiberPortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.7 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the fiber port. | ||||
| Ccm100ConfigFiberPortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.8 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the fiber port is enabled. | ||||
| Ccm100ConfigCopperPortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.9 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the copper port. | ||||
| Ccm100ConfigCopperPortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.10 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the fiber port is enabled. | ||||
| Ccm100ConfigCopperAutoNegotiation | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.11 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the whether copper auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm100ConfigCopperCrossOver | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.12 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the copper MDI/MDI-X setting.This object is read-only if the media converter module's ConfigMode jumper is set to
| ||||
| Ccm100ConfigCopperPause | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.13 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the copper's port pause (flow control) settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Tcm100LedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3 | NA | ||
table · not-accessible · current Table of CM-100 type media converter module's LED status information. | ||||
| Rcm100LedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-100 type media converter module. | ||||
| Ccm100LedSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-100 type module is currently inserted | ||||
| Ccm100LedPWR | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1.3 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the power (PWR) LED on the media converter module.
Possible status values are:
off(0) - No power to the module
onGreen(1) - Power being applied to module
blinking(2) - Fiber loopback enabled
| ||||
| Ccm100LedLKF | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link fiber (LKF) LED on the media converter module.
Possible status values are:
off(0) - No fiber link
on(1) - Fiber link present
| ||||
| Ccm100LedLKC | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link copper (LKC) LED on the
media converter module.
Possible status values are:
off(0) - No copper link
on(1) - Copper link present
| ||||
| Ncm1110RateConv | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3 | |||
| Tcm1110RateConvTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1 | NA | ||
table · not-accessible · current Table of CM-1110 type media converter module's configuration and status type information. | ||||
| Rcm1110RateConvEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1110 type media converter module. | ||||
| Ccm1110SlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1110 type module is currently inserted | ||||
| Ccm1110ModelName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the model of media converter module present in the chassis | ||||
| Ccm1110ModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the media converter module present in the chassis | ||||
| Ccm1110HwJmp5ConfigMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers.
| ||||
| Ccm1110HwJmp6AutoMDIX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module's hardware Auto MDIX jumper settings.
| ||||
| Ccm1110HwSw1TpAutoNegotiation | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for copper Auto-Negotiation.
| ||||
| Ccm1110HwSw2LinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Link Mode.
| ||||
| Ccm1110HwSw3FiberFaultAlert | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.9 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Fiber Fault Alert.
| ||||
| Ccm1110HwSw4TpDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.10 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for copper duplex.
| ||||
| Ccm1110HwSw5TpSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Link Mode.
| ||||
| Ccm1110HwSw6FiberAutoNegotiation | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for fiber Auto-Ngotiation. This object is not applicable if there is a 100 Mbps SFP modules inserted.
| ||||
| Ccm1110HwSw6FiberSfp100Duplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.13 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for fiber duplex if a 100 Mbps SFP module is inserted. Otherwise this object is not applicable.
| ||||
| Ccm1110HwSw7Loopback | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.14 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for fiber loopback mode.
| ||||
| Ccm1110FiberLinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.15 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status.
| ||||
| Ccm1110FiberConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.16 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type.
| ||||
| Ccm1110FiberAutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.17 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber auto-negotiation state. This object is not applicable if the fiber connector type is a 100 Mbps SFP module.
| ||||
| Ccm1110FiberSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.18 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm1110FiberDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.19 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the current fiber port duplex state.
| ||||
| Ccm1110FiberPauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.20 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm1110FiberLPRFStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.21 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber Link Partner Remote Fault status. This object is not applicable if there is a 100 Mbps SFP module inserted.
| ||||
| Ccm1110FiberSfp100FarEndFault | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.22 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber Far End Fault status if a 100 Mbps SFP module is inserted. Otherwise this object is not applicable.
| ||||
| Ccm1110FiberReceiveStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.23 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the status of whether light is being received on the fiber port
| ||||
| Ccm1110FiberLoopBack | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.24 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm1110CopperLinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.25 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current copper link status.
| ||||
| Ccm1110CopperConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.26 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's copper connector type.
| ||||
| Ccm1110CopperAutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.27 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current copper auto-negotiation state.
| ||||
| Ccm1110CopperSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.28 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated speed setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm1110CopperDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.29 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm1110CopperCrossOver | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.30 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm1110CopperPauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.31 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm1110CopperLPRFStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.32 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's copper Link Partner Remote Fault status.
| ||||
| Ccm1110CopperAutoSpeedDownshift | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.33 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the copper auto speed downshift feature. noDownshift indicates that an automatic downshift of the copper speed has not occurred.
| ||||
| Tcm1110ConfigTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2 | NA | ||
table · not-accessible · current Table of CM-1110 type media converter module's configuration type information. | ||||
| Rcm1110ConfigEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1110 type media converter module. | ||||
| Ccm1110ConfigSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1110 type module is currently inserted | ||||
| Ccm1110ConfigStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.3 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| Ccm1110ConfigModuleName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.4 | DisplayString (SIZE (0..63)) | RW | |
column · DisplayString (SIZE (0..63)) · read-write · current This object identifies a user configurable name for the media converter module present in the chassis. | ||||
| Ccm1110ConfigLinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm1110ConfigFiberFaultAlert | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.6 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the Fiber Fault Alert setting for the media module. For 100 Mbps SFP modules, this setting is always effectively enabled if Link Mode is set to smartLinkPassthrough. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm1110ConfigMaxPacketsSize | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.7 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the media converter module's maximum packet size setting This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm1110ConfigFiberPortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.8 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the fiber port. | ||||
| Ccm1110ConfigFiberPortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.9 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the fiber port is enabled. | ||||
| Ccm1110ConfigFiberAutoNegotiation | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.10 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies whether fiber auto-negotiation is enabled. This object does not apply if the fiber connector type is a 100 Mbps SFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm1110ConfigFiberSfp100duplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.11 | INTEGER | RW | |
column · INTEGER · read-write · current If the fiber connector type is SFP and it is a 100 Mbps fiber module then this object identifies the duplex setting for the 100 Mbps fiber port. Duplex for 1000 Mbps has to be auto negotiated. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm1110ConfigCopperPortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.12 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the copper port. | ||||
| Ccm1110ConfigCopperPortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.13 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the fiber port is enabled. | ||||
| Ccm1110ConfigCopperAutoNegotiation | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.14 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the whether copper auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm1110ConfigCopperAutoNegAdv10HDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.15 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the copper port advertises willingness to connect at 10Mbps, half duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| Ccm1110ConfigCopperAutoNegAdv10FDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.16 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the copper port advertises willingness to connect at 10Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| Ccm1110ConfigCopperAutoNegAdv100HDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.17 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the copper port advertises willingness to connect at 100Mbps, half duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| Ccm1110ConfigCopperAutoNegAdv100FDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.18 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the copper port advertises willingness to connect at 100Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| Ccm1110ConfigCopperAutoNegAdv1000FDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.19 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the copper port advertises willingness to connect at 1000Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| Ccm1110ConfigCopperSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.20 | INTEGER | RW | |
column · INTEGER · read-write · current If copper auto-negotiation is disabled then this object identifies the configured cooper speed. 1000 Mbps speed can only be auto negotiated. If copper auto-negotiation is enabled then this object is ignored. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm1110ConfigCopperDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.21 | INTEGER | RW | |
column · INTEGER · read-write · current If copper auto-negotiation is disabled then this object identifies the duplex setting for 10 & 100 Mbps for the copper port. Duplex for 1000 Mbps has to be auto negotiated. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm1110ConfigCopperCrossOver | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.22 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the copper MDI/MDI-X setting.This object is read-only if the media converter module's ConfigMode jumper is set to
| ||||
| Ccm1110ConfigCopperPauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.23 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the copper pause (flow control) setting that is a advertised. The settings can be disabled, advertise symmetrical, advertise asymmetrical TX or advertise symmetrical and asymmetrical RX. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm1110ConfigCopperAutoSpeedDownshift | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.24 | INTEGER (0..8) | RW | |
column · INTEGER (0..8) · read-write · current This object identifies the number of times the PHY attempts to establish a Gigabit link before the PHY downshift to the next highest speed. A value of 0 indicates the auto downshift is disabled | ||||
| Ccm1110ConfigCopper10BaseTDistance | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.25 | INTEGER | RW | |
column · INTEGER · read-write · current When using cable exceeding 100 meters in 10BASE-T mode this feature should be set to extended(1).
| ||||
| Ccm1110ConfigUnidirectionalEthernet | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.26 | INTEGER | RW | |
column · INTEGER · read-write · current Restrict the flow of Ethernet traffic to a single direction. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm1110ConfigPriorityToEgressQueueMap0 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.27 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigPriorityToEgressQueueMap1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.28 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigPriorityToEgressQueueMap2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.29 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigPriorityToEgressQueueMap3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.30 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigPriorityToEgressQueueMap4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.31 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigPriorityToEgressQueueMap5 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.32 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigPriorityToEgressQueueMap6 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.33 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigPriorityToEgressQueueMap7 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.34 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopper8021pPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.35 | OnOffValue | RW | |
column · OnOffValue · read-write · current Use 802.1p tag priority. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperIpTosPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.36 | OnOffValue | RW | |
column · OnOffValue · read-write · current Use IP TOS priority. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperPriorityPrecedence | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.37 | INTEGER | RW | |
column · INTEGER · read-write · current Configure priority precedence. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm1110ConfigCopperCongestionPolicy | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.38 | INTEGER | RW | |
column · INTEGER · read-write · current Configure priority congestion policy. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm1110ConfigCopperPriorityMap0 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.39 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperPriorityMap1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.40 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperPriorityMap2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.41 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperPriorityMap3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.42 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperPriorityMap4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.43 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperPriorityMap5 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.44 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperPriorityMap6 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.45 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperPriorityMap7 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.46 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperIngressLimit | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.47 | INTEGER | RW | |
column · INTEGER · read-write · current Set a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm1110ConfigCopperEgressLimit | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.48 | INTEGER | RW | |
column · INTEGER · read-write · current Set a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm1110ConfigCopperDiscardTaggedFrames | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.49 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable discarding of tagged frames. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperDiscardUntaggedFrames | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.50 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable discarding of untagged frames. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperDefaultVlanId | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.51 | INTEGER (0..4095) | RW | |
column · INTEGER (0..4095) · read-write · current Set the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperDefaultPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.52 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Set the default frame priority. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperVlanTaggingAction | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.53 | INTEGER | RW | |
column · INTEGER · read-write · current Set the default tagging action. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm1110ConfigCopperFilterUnknownMulticast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.54 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigCopperFilterUnknownUnicast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.55 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiber8021pPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.56 | OnOffValue | RW | |
column · OnOffValue · read-write · current Use 802.1p tag priority. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberIpTosPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.57 | OnOffValue | RW | |
column · OnOffValue · read-write · current Use IP TOS priority. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberPriorityPrecedence | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.58 | INTEGER | RW | |
column · INTEGER · read-write · current Configure priority precedence. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm1110ConfigFiberCongestionPolicy | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.59 | INTEGER | RW | |
column · INTEGER · read-write · current Configure priority congestion policy. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm1110ConfigFiberPriorityMap0 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.60 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberPriorityMap1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.61 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberPriorityMap2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.62 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberPriorityMap3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.63 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberPriorityMap4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.64 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberPriorityMap5 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.65 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberPriorityMap6 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.66 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberPriorityMap7 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.67 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberIngressLimit | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.68 | INTEGER | RW | |
column · INTEGER · read-write · current Set a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm1110ConfigFiberEgressLimit | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.69 | INTEGER | RW | |
column · INTEGER · read-write · current Set a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm1110ConfigFiberDiscardTaggedFrames | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.70 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable discarding of tagged frames. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberDiscardUntaggedFrames | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.71 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable discarding of untagged frames. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberDefaultVlanId | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.72 | INTEGER (0..4095) | RW | |
column · INTEGER (0..4095) · read-write · current Set the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberDefaultPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.73 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Set the default frame priority. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberVlanTaggingAction | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.74 | INTEGER | RW | |
column · INTEGER · read-write · current Set the default tagging action. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm1110ConfigFiberFilterUnknownMulticast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.75 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberFilterUnknownUnicast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.76 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | ||||
| Ccm1110ConfigFiberSgmiiInterface | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.77 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies whether fiber SGMII interface is enabled. | ||||
| Tcm1110LedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3 | NA | ||
table · not-accessible · current Table of CM-1110 type media converter module's LED status information. | ||||
| Rcm1110LedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1110 type media converter module. | ||||
| Ccm1110LedSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1110 type module is currently inserted | ||||
| Ccm1110LedPWR | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.3 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the power (PWR) LED on the media converter module.
Possible status values are:
off(0) - No power to the module
onGreen(1) - Power being applied to module
blinking(2) - Fiber loopback enabled
| ||||
| Ccm1110LedFDF | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the Full Duplex Fiber (FDF) LED on the media converter module.
| ||||
| Ccm1110LedLKF | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link fiber (LKF) LED on the
media converter module.
Possible status values are:
off(0) - No fiber link
on(1) - Fiber link present
| ||||
| Ccm1110LedCopperSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link copper speed (100/1000) LED on the management module.
| ||||
| Ccm1110LedFDC | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the Full Duplex Copper (FDC) LED on the media converter module.
| ||||
| Ccm1110LedLKC | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link copper (LKC) LED on the
media converter module. Possible status values are:
off(0) - No copper link
on(1) - Copper link present
| ||||
| Tcm1110RateConvStatsTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4 | NA | ||
table · not-accessible · current Table of CM-1110 type media converter module's configuration and status type information. | ||||
| Rcm1110RateConvStatsEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1110 type media converter module. | ||||
| Ccm1110StatsSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1110 type module is currently inserted | ||||
| Ccm1110MediaPortIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.3 | INTEGER | NA | |
column · INTEGER · not-accessible · current Media converter module port index indicating which media port the statistical counters are associated with.
| ||||
| Ccm1110PortInDiscards | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.4 | Counter32 | RO | |
column · Counter32 · read-only · current A counter that counts the number of good, non-filtered frames that normally would have been forwarded, but could not due to lack of buffer space. | ||||
| Ccm1110PortInFiltered | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.5 | INTEGER (0..65535) | RO | |
column · INTEGER (0..65535) · read-only · current A counter that counts the number of good frames that were filtered due to ingress switch policy rules. | ||||
| Ccm1110PortInGoodOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.6 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that is the sum of lengths of all good Ethernet frames received on the media port. | ||||
| Ccm1110PortHCInGoodOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.7 | Counter64 | RO | |
column · Counter64 · read-only · current An ingress counter that is the sum of lengths of all good Ethernet frames received on the media port. This object is a 64-bit version of cm1110PortInGoodOctets. | ||||
| Ccm1110PortInBadOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.8 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that is the sum of lengths of all bad Ethernet frames received on the media port.. | ||||
| Ccm1110PortInUnicasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.9 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of good frames received that have a Unicast destination MAC address. | ||||
| Ccm1110PortInBroadcasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.10 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of good frames received that have a Broadcast destination MAC address. | ||||
| Ccm1110PortInMulticasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.11 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of good frames received that have a Multicast destination MAC address. This count does not include frames counted in the cm1110PortInPauses or the cm1110PortInBroadcasts objects. | ||||
| Ccm1110PortInPauses | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.12 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of good frames reachieved that have a Pause destination MAC address. | ||||
| Ccm1110PortInUnderSizes | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.13 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a length less that 64 octets but with a valid FCS. | ||||
| Ccm1110PortInFragments | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.14 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a length less that 64 octets and an invalid FCS. | ||||
| Ccm1110PortInOversizes | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.15 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a length more than the maximum packet size but with a valid FCS. The maximum packet size can be set using the cm1110ConfigMaxPacketsSize object. | ||||
| Ccm1110PortInJabbers | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.16 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a length more than the maximum packet size but with a invalid FCS. The maximum packet size can be set using the cm1110ConfigMaxPacketsSize object. | ||||
| Ccm1110PortInRxErrs | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.17 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with an RxErr signal from the PHY. | ||||
| Ccm1110PortInFcsErrs | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.18 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a CRC error not counted in the cm1110PortInFragments, cm1110PortInFcsErr, or the cm1110PortInRxErr objects. | ||||
| Ccm1110PortPkts64Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.19 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of exactly 64 Octets, including those with errors. | ||||
| Ccm1110PortPkts65to127Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.20 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 65 and 127 Octets inclusive, including those with errors. | ||||
| Ccm1110PortPkts128to255Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.21 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 128 and 255 Octets inclusive, including those with errors. | ||||
| Ccm1110PortPkts256to511Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.22 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 256 and 511 Octets inclusive, including those with errors. | ||||
| Ccm1110PortPkts512to1023Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.23 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 512 and 1023 Octets inclusive, including those with errors. | ||||
| Ccm1110PortPkts1024toMaxOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.24 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 1024 and maximum packet size octets inclusive, including those with errors. The maximum packet size can be set using the cm1110ConfigMaxPacketsSize object. | ||||
| Ccm1110PortOutOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.25 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port. | ||||
| Ccm1110PortHCOutOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.26 | Counter64 | RO | |
column · Counter64 · read-only · current An Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port. This object is a 64-bit version of cm1110PortOutOctets. | ||||
| Ccm1110PortOutFiltered | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.27 | INTEGER (0..65535) | RO | |
column · INTEGER (0..65535) · read-only · current A counter that counts the number of good frames that were filtered due to egress switch policy rules. | ||||
| Ccm1110PortOutUnicasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.28 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of good frames sent that have a Unicast destination MAC address. | ||||
| Ccm1110PortOutBroadcasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.29 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of good frames sent that have a Broadcast destination MAC address. | ||||
| Ccm1110PortOutMulticasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.30 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of good frames sent that have a Multicast destination MAC address. This count does not include frames counted in the cm1110PortOutPauses or the cm1110PortOutBroadcasts objects. | ||||
| Ccm1110PortOutPauses | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.31 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of good frames reachieved that have a Pause destination MAC address. | ||||
| Ccm1110PortDeferreds | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.32 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of successfully transmitted frames that experienced no collisions but are delayed because the medium was busy during the first attempt. This counter is applicable in half-duplex only. | ||||
| Ccm1110PortCollisions | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.33 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of collision events seen by the MAC not including those counted in cm1110PortSingles, cm1110PortMultiple , cm1110PortExcessives or cm1110PortLates objects. This counter is applicable in half-duplex only. | ||||
| Ccm1110PortSingles | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.34 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of successfully transmitted frames that experienced exactly one collision. This counter is applicable in half-duplex only. | ||||
| Ccm1110PortMultiples | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.35 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of successfully transmitted frames that experienced more than one collision. This counter is aplicable in half-duplex only. | ||||
| Ccm1110PortExcessives | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.36 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number frames dropped in the transmit MAC because the frame experienced 16 consecutive collisions. This counter is applicable in half-duplex only. | ||||
| Ccm1110PortLates | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.37 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number times a collision is detected later than 512 bits-times into the transmission of a frame. This counter is applicable in half-duplex only. | ||||
| Ccm1110PortOutFcsErrs | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.38 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number frames transmitted with an invalid FCS. | ||||
| Ccm1110PortResetCounters | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.39 | YesNoValue | RW | |
column · YesNoValue · read-write · current Allows the resetting of all cm1110RateConvStats statistical counters for this port. | ||||
| Tcm1110RateConvAvctTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5 | NA | ||
table · not-accessible · current Table of CM-1110 type media converter module's | ||||
| Rcm1110RateConvAvctEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate fiber or copper port on the CM-1110 type media converter module. | ||||
| Ccm1110AvctSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1110 type module is currently inserted | ||||
| Ccm1110AvctStart | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.3 | YesNoValue | RW | |
column · YesNoValue · read-write · current Set this self-clearing variable to yes initiate the Advanced Virtual Cable Test. Note: During the test, no network data will be passed. | ||||
| Ccm1110AvctStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the state of the Advanced Virtual Cable Tester.
| ||||
| Ccm1110AvctTxRxPair1Results | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current Test result code returned from Virtual Cable Test of the Tx/Rx pair one.
| ||||
| Ccm1110AvctTxRxPair1Amplitude | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.6 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Amplitude of Tx/Rx pair one in millivolts when test result codes is short or open. | ||||
| Ccm1110AvctTxRxPair1Distance | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.7 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Distance in meters to fault when test result codes for Tx/Rx pair one is short or open. | ||||
| Ccm1110AvctTxRxPair2Results | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Test result code returned from Virtual Cable Test of the Tx/Rx pair two.
| ||||
| Ccm1110AvctTxRxPair2Amplitude | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.9 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Amplitude of Tx/Rx pair two in millivolts when test result codes is short or open. | ||||
| Ccm1110AvctTxRxPair2Distance | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.10 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Distance in meters to fault when test result codes for Tx/Rx pair two is short or open. | ||||
| Ccm1110AvctTxRxPair3Results | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current Test result code returned from Virtual Cable Test of the Tx/Rx pair three.
| ||||
| Ccm1110AvctTxRxPair3Amplitude | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.12 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Amplitude of Tx/Rx pair three in millivolts when test result codes is short or open. | ||||
| Ccm1110AvctTxRxPair3Distance | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.13 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Distance in meters to fault when test result codes for Tx/Rx pair three is short or open. | ||||
| Ccm1110AvctTxRxPair4Results | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.14 | INTEGER | RO | |
column · INTEGER · read-only · current Test result code returned from Virtual Cable Test of Tx/Rx pair four.
| ||||
| Ccm1110AvctTxRxPair4Amplitude | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.15 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Amplitude of Tx/Rx pair four in millivolts when test result codes is short or open. | ||||
| Ccm1110AvctTxRxPair4Distance | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.16 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Distance in meters to fault when test result codes for Tx/Rx pair four is short or open. | ||||
| Ncm110RateConv | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4 | |||
| Tcm110RateConvTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1 | NA | ||
table · not-accessible · current Table of CM-110 type media converter module's configuration and status type information. | ||||
| Rcm110RateConvEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-110 type media converter module. | ||||
| Ccm110SlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-110 type module is currently inserted | ||||
| Ccm110Modelname | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the model of media converter module present in the chassis | ||||
| Ccm110ModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the media converter module present in the chassis | ||||
| Ccm110HwJmp5ConfigMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers.
| ||||
| Ccm110HwJmp6AutoMDIX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module's hardware Auto MDIX jumper settings.
| ||||
| Ccm110HwSw1TpAutoNegotiation | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for copper auto-negotiation.
| ||||
| Ccm110HwSw2LinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Link Mode.
| ||||
| Ccm110HwSw3FarEndFault | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.9 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Far End Fault.
| ||||
| Ccm110HwSw4TpDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.10 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for copper duplex.
| ||||
| Ccm110HwSw5TpSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Link Mode.
| ||||
| Ccm110HwSw6FiberDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for fiber duplex.
| ||||
| Ccm110HwSw7Loopback | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.13 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for fiber loopback mode.
| ||||
| Ccm110FiberLinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.14 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status.
| ||||
| Ccm110FiberConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.15 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type.
| ||||
| Ccm110FiberSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.16 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port speed in megabits per second.
| ||||
| Ccm110FiberFarEndFault | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.17 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber Far End Fault status.
| ||||
| Ccm110FiberReceiveStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.18 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the status of whether light is being received on the fiber port
| ||||
| Ccm110FiberLoopBack | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.19 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm110CopperLinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.20 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current copper link status.
| ||||
| Ccm110CopperConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.21 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's copper connector type.
| ||||
| Ccm110CopperAutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.22 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current copper auto-negotiation state.
| ||||
| Ccm110CopperSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.23 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated speed setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm110CopperDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.24 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm110CopperCrossOver | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.25 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm110CopperPause | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.26 | INTEGER | RO | |
column · INTEGER · read-only · current If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated pause (flow control) setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| Ccm110CopperLPRFStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.27 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber Link Partner Remote Fault status.
| ||||
| Tcm110ConfigTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2 | NA | ||
table · not-accessible · current Table of CM-110 type media converter module's configuration and status type information. | ||||
| Rcm110ConfigEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-110 type media converter module. | ||||
| Ccm110ConfigSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-110 type module is currently inserted | ||||
| Ccm110ConfigStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.3 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| Ccm110ConfigModuleName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.4 | DisplayString (SIZE (0..63)) | RW | |
column · DisplayString (SIZE (0..63)) · read-write · current This object identifies a user configurable name for the media converter module present in the chassis. | ||||
| Ccm110ConfigLinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm110ConfigFiberFarEndFault | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.6 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the Fiber Fault Alert setting for the media module. This setting is always enabled if Link Mode is set to linkPassthrough. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm110ConfigMaxPacketSize | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.7 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the media converter module's maximum packet size setting This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm110ConfigFiberPortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.8 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the fiber port. | ||||
| Ccm110ConfigFiberPortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.9 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the fiber port is enabled. | ||||
| Ccm110ConfigFiberDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.10 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the fiber port duplex setting.
| ||||
| Ccm110ConfigCopperPortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.11 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the copper port. | ||||
| Ccm110ConfigCopperPortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.12 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the fiber port is enabled. | ||||
| Ccm110ConfigCopperAutoNegotiation | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.13 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the whether copper auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm110ConfigCopperAutoNegAdv10HDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.14 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the copper port advertises willingness to connect at 10Mbps, half duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| Ccm110ConfigCopperAutoNegAdv10FDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.15 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the copper port advertises willingness to connect at 10Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| Ccm110ConfigCopperAutoNegAdv100HDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.16 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the copper port advertises willingness to connect at 100Mbps, half duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| Ccm110ConfigCopperAutoNegAdv100FDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.17 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the copper port advertises willingness to connect at 100Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| Ccm110ConfigCopperSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.18 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the current copper speed in megabits per second. This object is ignored if auto-negotiation is enabled. This object is ignored if auto-negotiation is enabled
| ||||
| Ccm110ConfigCopperDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.19 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the copper duplex setting. This object is ignored if auto-negotiation is enabled This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm110ConfigCopperCrossOver | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.20 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the copper MDI/MDI-X setting.This object is read-only if the media converter module's ConfigMode jumper is set to
| ||||
| Ccm110ConfigCopperPause | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.21 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the copper's pause (flow control) settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm110ConfigCopperExtendDistance | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.22 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current When using cable exceeding 100 meters, the 10BASE-T this feature should be enabled. | ||||
| Ccm110ConfigUnidirectionalEthernet | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.23 | INTEGER | RW | |
column · INTEGER · read-write · current Restrict the flow of Ethernet traffic to a single direction. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm110ConfigPriorityToEgressQueueMap0 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.24 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigPriorityToEgressQueueMap1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.25 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigPriorityToEgressQueueMap2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.26 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigPriorityToEgressQueueMap3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.27 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigPriorityToEgressQueueMap4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.28 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigPriorityToEgressQueueMap5 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.29 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigPriorityToEgressQueueMap6 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.30 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigPriorityToEgressQueueMap7 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.31 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopper8021pPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.32 | OnOffValue | RW | |
column · OnOffValue · read-write · current Use 802.1p tag priority. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperIpTosPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.33 | OnOffValue | RW | |
column · OnOffValue · read-write · current Use IP TOS priority. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperPriorityPrecedence | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.34 | INTEGER | RW | |
column · INTEGER · read-write · current Configure priority precedence. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm110ConfigCopperCongestionPolicy | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.35 | INTEGER | RW | |
column · INTEGER · read-write · current Configure priority congestion policy. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm110ConfigCopperPriorityMap0 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.36 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperPriorityMap1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.37 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperPriorityMap2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.38 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperPriorityMap3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.39 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperPriorityMap4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.40 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperPriorityMap5 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.41 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperPriorityMap6 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.42 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperPriorityMap7 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.43 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperIngressLimit | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.44 | INTEGER | RW | |
column · INTEGER · read-write · current Set a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm110ConfigCopperEgressLimit | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.45 | INTEGER | RW | |
column · INTEGER · read-write · current Set a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm110ConfigCopperDiscardTaggedFrames | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.46 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable discarding of tagged frames. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperDiscardUntaggedFrames | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.47 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable discarding of untagged frames. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperDefaultVlanId | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.48 | INTEGER (0..4095) | RW | |
column · INTEGER (0..4095) · read-write · current Set the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperDefaultPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.49 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Set the default frame priority. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperVlanTaggingAction | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.50 | INTEGER | RW | |
column · INTEGER · read-write · current Set the default tagging action. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm110ConfigCopperFilterUnknownMulticast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.51 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigCopperFilterUnknownUnicast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.52 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiber8021pPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.53 | OnOffValue | RW | |
column · OnOffValue · read-write · current Use 802.1p tag priority. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberIpTosPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.54 | OnOffValue | RW | |
column · OnOffValue · read-write · current Use IP TOS priority. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberPriorityPrecedence | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.55 | INTEGER | RW | |
column · INTEGER · read-write · current Configure priority precedence. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm110ConfigFiberCongestionPolicy | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.56 | INTEGER | RW | |
column · INTEGER · read-write · current Configure priority congestion policy. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm110ConfigFiberPriorityMap0 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.57 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberPriorityMap1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.58 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberPriorityMap2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.59 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberPriorityMap3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.60 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberPriorityMap4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.61 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberPriorityMap5 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.62 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberPriorityMap6 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.63 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberPriorityMap7 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.64 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberIngressLimit | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.65 | INTEGER | RW | |
column · INTEGER · read-write · current Set a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm110ConfigFiberEgressLimit | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.66 | INTEGER | RW | |
column · INTEGER · read-write · current Set a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm110ConfigFiberDiscardTaggedFrames | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.67 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable discarding of tagged frames. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberDiscardUntaggedFrames | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.68 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable discarding of untagged frames. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberDefaultVlanId | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.69 | INTEGER (0..4095) | RW | |
column · INTEGER (0..4095) · read-write · current Set the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberDefaultPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.70 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Set the default frame priority. (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberVlanTaggingAction | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.71 | INTEGER | RW | |
column · INTEGER · read-write · current Set the default tagging action. (This feature may require a media converter module firmware upgrade).
| ||||
| Ccm110ConfigFiberFilterUnknownMulticast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.72 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | ||||
| Ccm110ConfigFiberFilterUnknownUnicast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.73 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | ||||
| Tcm110LedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3 | NA | ||
table · not-accessible · current Table of CM-110 type media converter module's LED status information. | ||||
| Rcm110LedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-110 type media converter module. | ||||
| Ccm110LedSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-110 type module is currently inserted | ||||
| Ccm110LedPWR | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.3 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the power (PWR) LED on the media converter module.
Possible status values are:
off(0) - No power to the module
onGreen(1) - Power being applied to module
blinking(2) - Fiber loopback enabled
| ||||
| Ccm110LedFDF | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the Full Duplex Fiber (FDF) LED on the media converter module.
| ||||
| Ccm110LedLKF | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link fiber (LKF) LED on the
media converter module.
Possible status values are:
off(0) - No fiber link
on(1) - Fiber link present
| ||||
| Ccm110LedCopperSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link copper speed (100/1000) LED on the media converter module.
| ||||
| Ccm110LedFDC | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the Full Duplex Copper (FDC) LED on the media converter module.
| ||||
| Ccm110LedLKC | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link copper (LKC) LED on the
media converter module. Possible status values are:
off(0) - No copper link
on(1) - Copper link present
| ||||
| Tcm110RateConvStatsTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4 | NA | ||
table · not-accessible · current Table of CM-110 media converter module's configuration and status type information. | ||||
| Rcm110RateConvStatsEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-110 type media converter module. | ||||
| Ccm110StatsSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-110 type module is currently inserted | ||||
| Ccm110MediaPortIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.3 | INTEGER | NA | |
column · INTEGER · not-accessible · current Media converter module port index indicating which media port the statistical counters are associated with.
| ||||
| Ccm110PortRxErrors | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.4 | INTEGER (0..65535) | RO | |
column · INTEGER (0..65535) · read-only · current Total number of bad frames received. | ||||
| Ccm110PortTxCollisions | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.5 | INTEGER (0..65535) | RO | |
column · INTEGER (0..65535) · read-only · current Total number of TX collisions encountered. | ||||
| Ccm110PortInFiltered | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.6 | INTEGER (0..65535) | RO | |
column · INTEGER (0..65535) · read-only · current A counter that counts the number of good frames that were filtered due to ingress switch policy rules. | ||||
| Ccm110PortInGoodOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.7 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that is the sum of lengths of all good Ethernet frames received on the media port. | ||||
| Ccm110PortInBadOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.8 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that is the sum of lengths of all bad Ethernet frames received on the media port.. | ||||
| Ccm110PortInUnicasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.9 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of good frames received that have a Unicast destination MAC address. | ||||
| Ccm110PortInBroadcasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.10 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of good frames received that have a Broadcast destination MAC address. | ||||
| Ccm110PortInMulticasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.11 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of good frames received that have a Multicast destination MAC address. This count does not include frames counted in the cm1110PortInPauses or the cm1110PortInBroadcasts objects. | ||||
| Ccm110PortInPauses | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.12 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of good frames received that have a Pause destination MAC address. | ||||
| Ccm110PortInUnderSizes | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.13 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a length less that 64 octets but with a valid FCS. | ||||
| Ccm110PortInFragments | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.14 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a length less that 64 octets and an invalid FCS. | ||||
| Ccm110PortInOversizes | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.15 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a length more than the maximum packet size but with a valid FCS. The maximum packet size can be set using the cm110ConfigMaxPacketsSize object. | ||||
| Ccm110PortInJabbers | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.16 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a length more than the maximum packet size but with a invalid FCS. The maximum packet size can be set using the cm110ConfigMaxPacketsSize object. | ||||
| Ccm110PortInMACRcvErrs | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.17 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter of the number of Rx errors on the receive side of the MAC | ||||
| Ccm110PortInFcsErrs | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.18 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter of the number of FCS Errors. | ||||
| Ccm110PortPkts64Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.19 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of exactly 64 Octets, including those with errors. | ||||
| Ccm110PortPkts65to127Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.20 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 65 and 127 Octets inclusive, including those with errors. | ||||
| Ccm110PortPkts128to255Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.21 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 128 and 255 Octets inclusive, including those with errors. | ||||
| Ccm110PortPkts256to511Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.22 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 256 and 511 Octets inclusive, including those with errors. | ||||
| Ccm110PortPkts512to1023Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.23 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 512 and 1023 Octets inclusive, including those with errors. | ||||
| Ccm110PortPkts1024toMaxOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.24 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 1024 and maximum packet size octets inclusive, including those with errors. The maximum packet size can be set using the cm1110ConfigMaxPacketsSize object. | ||||
| Ccm110PortOutOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.25 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port. | ||||
| Ccm110PortOutUnicasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.26 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of good frames sent that have a Unicast destination MAC address. | ||||
| Ccm110PortOutBroadcasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.27 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of good frames sent that have a Broadcast destination MAC address. | ||||
| Ccm110PortOutMulticasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.28 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of good frames sent that have a Multicast destination MAC address. This count does not include frames counted in the cm1110PortOutPauses or the cm1110PortOutBroadcasts objects. | ||||
| Ccm110PortOutPauses | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.29 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of good frames received that have a Pause destination MAC address. | ||||
| Ccm110PortDeferreds | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.30 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of successfully transmitted frames that experienced no collsions but are delayed because the medium was busy during the first attempt. This counter is applicable in half-duplex only. | ||||
| Ccm110PortCollisions | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.31 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of collision events seen by the MAC not including those counted in cm110PortSingles, cm110PortMultiple , cm1110PortExcessives or cm110PortLates objects. This counter is applicable in half-duplex only. | ||||
| Ccm110PortSingles | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.32 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of successfully transmitted frames that experienced exactly one collision. This counter is applicable in half-duplex only. | ||||
| Ccm110PortMultiples | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.33 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of successfully transmitted frames that experienced more than one collision. This counter is aplicable in half-duplex only. | ||||
| Ccm110PortExcessives | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.34 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number frames dropped in the transmit MAC because the frame experienced 16 consecutive collisions. This counter is applicable in half-duplex only. | ||||
| Ccm110PortLates | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.35 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number times a collision is detected later than 512 bits-times into the transmission of a frame. This counter is applicable in half-duplex only. | ||||
| Ccm110PortOutFcsErrs | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.36 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number frames transmitted with an invalid FCS. | ||||
| Ccm110PortResetCounters | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.37 | YesNoValue | RW | |
column · YesNoValue · read-write · current Allows the resetting of all cm110RateConvStats statistical counters for this port. | ||||
| Tcm110RateConvVctTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5 | NA | ||
table · not-accessible · current Table of CM-110 type media converter module's | ||||
| Rcm110RateConvVctEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate fiber or copper port on the CM-110 type media converter module. | ||||
| Ccm110VctSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1110 type module is currently inserted | ||||
| Ccm110VctStart | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.3 | YesNoValue | RW | |
column · YesNoValue · read-write · current Set this self-clearing variable to yes initiate the Advanced Virtual Cable Test. Note: During the test, no network data will be passed. | ||||
| Ccm110VctStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the stat of the Advanced Virtual Cable Test.
| ||||
| Ccm110VctTxPairResults | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current Test result code returned from Virtual Cable Test of the Tx pair.
| ||||
| Ccm110VctTxPairAmplitude | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.6 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Amplitude of Tx pair in Volts. | ||||
| Ccm110VctTxPairDistance | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.7 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Distance in meters to fault when test result codes is short or open. | ||||
| Ccm110VctRxPairResults | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Test result code returned from Virtual Cable Test of the Rx pair.
| ||||
| Ccm110VctRxPairAmplitude | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.9 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Amplitude of Rx pair in Volts. | ||||
| Ccm110VctRxPairDistance | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.10 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Distance in meters to fault when test result codes is short or open. | ||||
| NmcrMgt | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5 | |||
| TmcrMgtTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1 | NA | ||
table · not-accessible · current Table of MCR-MGT management module status type information. | ||||
| RmcrMgtEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate MCR-MGT type management module. | ||||
| CmcrMgtSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the MCR-MGT module is currently inserted | ||||
| CmcrMgtModelName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the model name of management module present in the chassis | ||||
| CmcrMgtModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the management module present in the chassis | ||||
| CmcrMgtFailSafeBootLoaderVer | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.5 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the fail-safe bootloader version of the management module present in the chassis | ||||
| CmcrMgtUpTime | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.6 | TimeTicks | RO | |
column · TimeTicks · read-only · current This object identifies the time (in hundredths of a second) since the management module was last re-initialized. | ||||
| CmcrMgtConsoleDSR | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.7 | OnOffValue | RO | |
column · OnOffValue · read-only · current This object identifies the current status of the DSR signal, (active or inactive) | ||||
| TmcrMgtConfigTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2 | NA | ||
table · not-accessible · current Table of MCR-MGT management module Hardware configuration type information. | ||||
| RmcrMgtConfigEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate MCR-MGT type management module. | ||||
| CmcrMgtConfigSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the MCR-MGT module is currently inserted | ||||
| CmcrMgtConfigStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.3 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| CmcrMgtConfigEthSpeedDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.4 | INTEGER | RW | |
column · INTEGER · read-write · current Define the Ethernet connection speed/duplex of the twisted pair interface.
| ||||
| CmcrMgtConfigEthCrossover | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current Define the Ethernet connection crossover TX/RX Pair orientation of the twisted pair interface as auto(0), mdi(1) (straight through) or mdix(2) (crossed over).
| ||||
| CmcrMgtConfigConsolePortEnabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.6 | YesNoValue | RW | |
column · YesNoValue · read-write · current Determines whether the management module's console port is enabled. | ||||
| CmcrMgtConfigConsoleSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.7 | INTEGER | RW | |
column · INTEGER · read-write · current Specifies the baud rate of the console port; keep in mind that speed is affected by the length of the cable.
| ||||
| CmcrMgtConfigConsoleDataBits | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.8 | INTEGER | RW | |
column · INTEGER · read-write · current Specifies the number of bits in a byte.
| ||||
| CmcrMgtConfigConsoleParity | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.9 | INTEGER | RW | |
column · INTEGER · read-write · current Specifies if you are using Even, Odd, or No parity on the console.
| ||||
| CmcrMgtConfigConsoleStopBits | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.10 | INTEGER | RW | |
column · INTEGER · read-write · current Specifies the number of stop bits that follow a byte.
| ||||
| CmcrMgtConfigConsoleFlowControl | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.11 | INTEGER | RW | |
column · INTEGER · read-write · current Defines whether the data flow is handled by the software (Soft), hardware (Hard), both or None.
| ||||
| CmcrMgtConfigConsoleMonitorDSR | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.12 | OnOffValue | RW | |
column · OnOffValue · read-write · current Specifies whether the RS-232 signal DSR (Data Set Ready) should be monitored, for the console port. When DSR is monitored and the management module detects the DSR signal go inactive then the current console management session will be reset. | ||||
| TmcrMgtLedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3 | NA | ||
table · not-accessible · current Table of MCR-MGT management module LED information. | ||||
| RmcrMgtLedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate MCR-MGT type management module. | ||||
| CmcrMgtLedSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the MCR-MGT module is currently inserted | ||||
| CmcrMgtLedPWR | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.3 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the power (PWR) LED on the management module.
Possible status values are:
off(0) - No power to the module
onGreen(1) - Power being applied to module
| ||||
| CmcrMgtLedALM | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the alarm (ALM) LED on the management module.
Possible status values are:
offNoAlarms(0) - Normal operating condition
onRedAlarmsPresent(1) - System hardware or software alarms present
| ||||
| CmcrMgtLedLKC | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link copper (LKC) LED on the management module.
Possible status values are:
offLinkDown(0) - Copper link status is DOWN
onGreenLinkUp(1) - Copper link status is UP
| ||||
| CmcrMgtLedCopperSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link copper speed (100/1000) LED on the management module.
| ||||
| TmcrMgtEthStatsTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4 | NA | ||
table · not-accessible · current Table of MCR-MGT management module Ethernet status and statistics information. | ||||
| RmcrMgtEthStatsEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1 | NA | ||
row · not-accessible · current An entry in the Ethernet statistics table, each relating to an Ethernet interface. | ||||
| CmgtEthSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the MCR-MGT module is currently inserted. | ||||
| CmgtEthStatsIfIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.3 | GenericTableIndex | NA | |
column · GenericTableIndex · not-accessible · current The Ethernet interface number. | ||||
| CmgtEthStatsName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current Displays Ethernet interface name. | ||||
| CmgtEthStatsMacAddress | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.5 | MacAddress | RO | |
column · MacAddress · read-only · current Displays the MAC address. | ||||
| CmgtEthStatsStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current Displays the Ethernet link status - down(0) or up(1).
| ||||
| CmgtEthStatsSpeedDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current Current status of the Ethernet connection speed/duplex twisted pair interface. When the management module does not know the pair speed/duplex, this variable has the value unknown(0).
| ||||
| CmgtEthStatsBroadcast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.8 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet Broadcast Flags status. | ||||
| CmgtEthStatsDebug | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.9 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet Debug Flags status. | ||||
| CmgtEthStatsLoopback | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.10 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet Loopback Flags status. | ||||
| CmgtEthStatsPointtoPoint | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.11 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet Point to Point Flags status. | ||||
| CmgtEthStatsNoTrailers | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.12 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet No Trailers Flags status. | ||||
| CmgtEthStatsRunning | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.13 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet Running Flags status. | ||||
| CmgtEthStatsNoArp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.14 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet No Arp Protocol Flags status. | ||||
| CmgtEthStatsPromiscuous | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.15 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet Promiscuous Flags status. | ||||
| CmgtEthStatsRxMulticast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.16 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet Receive all Multicast Flags status. | ||||
| CmgtEthStatsMasterLoadBalancer | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.17 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet Master Load Balancer Flags status. | ||||
| CmgtEthStatsSlaveLoadBalancer | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.18 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet Slave Load Balancer Flags status. | ||||
| CmgtEthStatsMulticast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.19 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet Multicast Flags status. | ||||
| CmgtEthStatsSetMedia | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.20 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet Set Media Flags status. | ||||
| CmgtEthStatsAutoMedia | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.21 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet Auto Media Flags status. | ||||
| CmgtEthStatsDynamic | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.22 | YesNoValue | RO | |
column · YesNoValue · read-only · current The management module's Ethernet Dynamic Flags status. | ||||
| CmgtEthStatsLocalAddress | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.23 | IpAddress | RO | |
column · IpAddress · read-only · current The management module's Ethernet local IPv4 address. | ||||
| CmgtEthStatsSubnetMask | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.24 | IpAddress | RO | |
column · IpAddress · read-only · current The management module's Ethernet IPv4 subnet mask. | ||||
| CmgtEthStatsBroadcastAddress | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.25 | IpAddress | RO | |
column · IpAddress · read-only · current The management module's Ethernet Broadcast address. | ||||
| CmgtEthStatsMtu | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.26 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The management module's Ethernet MTU. | ||||
| CmgtEthStatsTxQLen | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.27 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The management module's Ethernet TX Queue Length. | ||||
| CmgtEthStatsRxBytes | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.28 | Counter32 | RO | |
column · Counter32 · read-only · current The management module's Ethernet RX Bytes count. | ||||
| CmgtEthStatsTxBytes | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.29 | Counter32 | RO | |
column · Counter32 · read-only · current The management module's Ethernet TX Bytes count. | ||||
| CmgtEthStatsRxPackets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.30 | Counter32 | RO | |
column · Counter32 · read-only · current The management module's Ethernet RX Packets count. | ||||
| CmgtEthStatsTxPackets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.31 | Counter32 | RO | |
column · Counter32 · read-only · current The management module's Ethernet TX Packets count. | ||||
| CmgtEthStatsRxErrors | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.32 | Counter32 | RO | |
column · Counter32 · read-only · current The management module's Ethernet RX Packets Errors count. | ||||
| CmgtEthStatsTxPktErrors | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.33 | Counter32 | RO | |
column · Counter32 · read-only · current The management module's Ethernet TX Packets Errors count. | ||||
| CmgtEthStatsRxDroppedPkts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.34 | Counter32 | RO | |
column · Counter32 · read-only · current The management module's Ethernet RX Dropped packets count. | ||||
| CmgtEthStatsTxDroppedPkts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.35 | Counter32 | RO | |
column · Counter32 · read-only · current The management module's Ethernet TX Dropped packets count. | ||||
| CmgtEthStatsRxOverruns | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.36 | Counter32 | RO | |
column · Counter32 · read-only · current The management module's Ethernet RX Overruns count | ||||
| CmgtEthStatsTxOverruns | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.37 | Counter32 | RO | |
column · Counter32 · read-only · current The management module's Ethernet TX Overruns count. | ||||
| CmgtEthStatsRxFrameErrs | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.38 | Counter32 | RO | |
column · Counter32 · read-only · current The management module's Ethernet RX Frame Errors count. | ||||
| CmgtEthStatsTxCarrierErrs | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.39 | Counter32 | RO | |
column · Counter32 · read-only · current The management module's Ethernet TX Carrier Errors count | ||||
| CmgtEthStatsCollisions | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.40 | Counter32 | RO | |
column · Counter32 · read-only · current The management module's Ethernet Collisions count. | ||||
| Ncm1000mmFixed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6 | |||
| Tcm1000mmFixedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1 | NA | ||
table · not-accessible · current Table of CM-1000MM type media converter module's status type information. | ||||
| Rcm1000mmFixedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1000MM type media converter module. | ||||
| Ccm1000mmSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1000MM type module is currently inserted | ||||
| Ccm1000mmModelname | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the model of media converter module present in the chassis | ||||
| Ccm1000mmModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the media converter module present in the chassis | ||||
| Ccm1000mmHwJmp5ConfigMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers.
| ||||
| Ccm1000mmHwSw1FiberAutoNeg | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for fiber Auto-Negotiation.
| ||||
| Ccm1000mmHwSw2LinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Link Mode.
| ||||
| Ccm1000mmHwSw3FiberFaultAlert | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Fiber Fault Alert.
| ||||
| Ccm1000mmHwSw4Loopback1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.9 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for loopback (fiber port 1).
| ||||
| Ccm1000mmHwSw5Loopback2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.10 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for loopback (fiber port 2).
| ||||
| Ccm1000mmFiber1LinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status (port 1).
| ||||
| Ccm1000mmFiber1ConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.13 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type (port 1).
| ||||
| Ccm1000mmFiber1AutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.14 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber auto-negotiation state (port 1).
| ||||
| Ccm1000mmFiber1Speed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.15 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port speed in megabits per second (port 1).
| ||||
| Ccm1000mmFiber1Duplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.16 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1)
| ||||
| Ccm1000mmFiber1PauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.17 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1)
| ||||
| Ccm1000mmFiber1LPRFStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.18 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber Link Partner Remote Fault status (port 1).
| ||||
| Ccm1000mmFiber1ReceiveStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.19 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the status of whether light is being received on the fiber port (port 1)
| ||||
| Ccm1000mmFiber2LinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.20 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status (port 2).
| ||||
| Ccm1000mmFiber2ConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.21 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type (port 2).
| ||||
| Ccm1000mmFiber2AutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.22 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber auto-negotiation state (port 2).
| ||||
| Ccm1000mmFiber2Speed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.23 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port speed in megabits per second (port 2).
| ||||
| Ccm1000mmFiber2Duplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.24 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2)
| ||||
| Ccm1000mmFiber2PauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.25 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2)
| ||||
| Ccm1000mmFiber2LPRFStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.26 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber Link Partner Remote Fault status (port 2).
| ||||
| Ccm1000mmFiber2ReceiveStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.27 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the status of whether light is being received on the fiber port (port 2)
| ||||
| Ccm1000mmFiberLoopBack | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.28 | INTEGER | RW | |
column · INTEGER · read-write · current Media converter module's current fiber loopback mode setting. Writing to this object will change the current settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Tcm1000mmConfigTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2 | NA | ||
table · not-accessible · current Table of CM-1000MM type media converter module's configuration type information. | ||||
| Rcm1000mmConfigEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1000MM type media converter module. | ||||
| Ccm1000mmConfigSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1000MM type module is currently inserted | ||||
| Ccm1000mmConfigStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.3 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| Ccm1000mmConfigModuleName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.4 | DisplayString (SIZE (0..63)) | RW | |
column · DisplayString (SIZE (0..63)) · read-write · current This object identifies a user configurable name for the media converter module present in the chassis. | ||||
| Ccm1000mmConfigLinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm1000mmConfigFiberFaultAlert | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.6 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm1000mmConfigJumboPackets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.7 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the Jumbo Packet setting for the media converter module present in the chassis. | ||||
| Ccm1000mmConfigFiberAutoNeg | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.8 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the wither fiber auto-negotiation is enabled for both ports. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm1000mmConfigFiber1PortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.9 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the fiber port (port 1). | ||||
| Ccm1000mmConfigFiber1PortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.10 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the fiber port is enabled (port 1). | ||||
| Ccm1000mmConfigFiber2PortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.11 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the fiber port (port 2). | ||||
| Ccm1000mmConfigFiber2PortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.12 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the fiber port is enabled (port 2). | ||||
| Tcm1000mmLedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3 | NA | ||
table · not-accessible · current Table of CM-1000MM type media converter module's LED status information. | ||||
| Rcm1000mmLedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1000MM type media converter module. | ||||
| Ccm1000mmLedsSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1000 type module is currently inserted | ||||
| Ccm1000mmLedPWR | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1.3 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the power (PWR) LED on the media converter module.
Possible status values are:
off(0) - No power to the module
onGreen(1) - Power being applied to module
blinking(2) - Fiber loopback enabled
| ||||
| Ccm1000mmLedLK1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link fiber port 1 (LK1) LED on the
media converter module.
Possible status values are:
off(0) - No fiber link
on(1) - Fiber link present
| ||||
| Ccm1000mmLedLK2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link fiber port 2 (LK2) LED on the
media converter module.
Possible status values are:
off(0) - No fiber link
on(1) - Fiber link present
| ||||
| Ncm100mmFixed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7 | |||
| Tcm100mmFixedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1 | NA | ||
table · not-accessible · current Table of CM-100MM type media converter module's configuration and status type information. | ||||
| Rcm100mmFixedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-100MM type media converter module. | ||||
| Ccm100mmSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-100MM type module is currently inserted | ||||
| Ccm100mmModelName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the model of media converter module present in the chassis | ||||
| Ccm100mmModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the media converter module present in the chassis | ||||
| Ccm100mmHwJmp5ConfigMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers.
| ||||
| Ccm100mmHwSw1LinkPassthrough | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Link Passthrough.
| ||||
| Ccm100mmHwSw2FarEndFault | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Far-End Fault.
| ||||
| Ccm100mmHwSw3Loopback1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Loopback (fiber port 1).
| ||||
| Ccm100mmHwSw4Loopback2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.9 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Loopback (fiber port 2).
| ||||
| Ccm100mmFiber1LinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status (port 1).
| ||||
| Ccm100mmFiber1ConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.13 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type (port 1).
| ||||
| Ccm100mmFiber1Speed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.14 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port speed in megabits per second (port 1).
| ||||
| Ccm100mmFiber1FarEndFault | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.15 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber Far End Fault status (port 1).
| ||||
| Ccm100mmFiber1ReceiveStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.16 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the status of whether light is being received on the fiber port (port 1)
| ||||
| Ccm100mmFiber2LinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.17 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status (port 2).
| ||||
| Ccm100mmFiber2ConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.18 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type (port 2).
| ||||
| Ccm100mmFiber2Speed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.19 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port speed in megabits per second (port 2).
| ||||
| Ccm100mmFiber2FarEndFault | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.20 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber Far End Fault status (port 2).
| ||||
| Ccm100mmFiber2ReceiveStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.21 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the status of whether light is being received on the fiber port (port 2)
| ||||
| Ccm100mmFiberLoopBack | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.22 | INTEGER | RW | |
column · INTEGER · read-write · current This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Tcm100mmConfigTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2 | NA | ||
table · not-accessible · current Table of CM-100MM type media converter module's configuration and status type information. | ||||
| Rcm100mmConfigEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-100MM type media converter module. | ||||
| Ccm100mmConfigSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-100MM type module is currently inserted | ||||
| Ccm100mmConfigStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.3 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| Ccm100mmConfigModuleName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.4 | DisplayString (SIZE (0..63)) | RW | |
column · DisplayString (SIZE (0..63)) · read-write · current This object identifies a user configurable name for the media converter module present in the chassis. | ||||
| Ccm100mmConfigLinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm100mmConfigFiberFarEndFault | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.6 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the fiber Far End Fault setting for the media module. This setting is always enabled if Link Mode is set to linkPassthrough. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm100mmConfigFiber1PortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.7 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the fiber port (port 1). | ||||
| Ccm100mmConfigFiber1PortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.8 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the fiber port is enabled (port 2). | ||||
| Ccm100mmConfigFiber2PortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.9 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the fiber port (port 2). | ||||
| Ccm100mmConfigFiber2PortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.10 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the fiber port is enabled (port 2). | ||||
| Tcm100mmLedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3 | NA | ||
table · not-accessible · current Table of CM-100MM type media converter module's LED status information. | ||||
| Rcm100mmLedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-100MM type media converter module. | ||||
| Ccm100mmLedSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-100MM type module is currently inserted | ||||
| Ccm100mmLedPWR | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1.3 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the power (PWR) LED on the media converter module.
Possible status values are:
off(0) - No power to the module
onGreen(1) - Power being applied to module
blinking(2) - Fiber loopback enabled
| ||||
| Ccm100mmLedLK1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link fiber port 1 (LK1) LED on the media converter module.
Possible status values are:
off(0) - No fiber link
on(1) - Fiber link present
| ||||
| Ccm100mmLedLK2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the link fiber port 2 (LK2) LED on the
media converter module.
Possible status values are:
off(0) - No fiber link
on(1) - Fiber link present
| ||||
| Ncm10gFixed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8 | |||
| Tcm10gFixedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1 | NA | ||
table · not-accessible · current Table of CM-10G type media converter module's status type information. | ||||
| Rcm10gFixedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-10G type media converter module. | ||||
| Ccm10gSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-10G type module is currently inserted | ||||
| Ccm10gModelname | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the model of media converter module present in the chassis | ||||
| Ccm10gModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the media converter module present in the chassis | ||||
| Ccm10gHwJmp5ConfigMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers.
| ||||
| Ccm10gHwSw1OperationMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for operation mode. Data mode is for normal data transmission.
| ||||
| Ccm10gHwSw2LinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Link Mode. If the Operation switch is set to Test, then this object indicates whether the port is in loopback or performing the build in link-test.
| ||||
| Ccm10gHwSw3FiberFaultAlert | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Fiber Fault Alert. If the Operation switch is set to Test, then this object indicates which port is in test mode
| ||||
| Ccm10gHwSw4Port1EdcMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.9 | INTEGER | RO | |
column · INTEGER · read-only · current This oject indicates the current switch setting for EDC auto mode for port 1. This object only applies to SFP moudles.
| ||||
| Ccm10gHwSw5Port2EdcMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.10 | INTEGER | RO | |
column · INTEGER · read-only · current This oject indicates the current switch setting for EDC auto mode for port 2. This object only applies to SFP moudles.
| ||||
| Ccm10gPort1LinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status (port 1).
| ||||
| Ccm10gPort1ConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type (port 1).
| ||||
| Ccm10gPort1AutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.13 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber auto-negotiation state (port 1).
| ||||
| Ccm10gPort1Speed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.14 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port speed in megabits per second (port 1).
| ||||
| Ccm10gPort1Duplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.15 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1)
| ||||
| Ccm10gPort1PauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.16 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1)
| ||||
| Ccm10gPort1ReceiveStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.17 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of whether light is being received on the fiber port (port 1)
| ||||
| Ccm10gPort2LinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.18 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status (port 2).
| ||||
| Ccm10gPort2ConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.19 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type (port 2).
| ||||
| Ccm10gPort2AutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.20 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber auto-negotiation state (port 2).
| ||||
| Ccm10gPort2Speed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.21 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port speed in megabits per second (port 2).
| ||||
| Ccm10gPort2Duplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.22 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2)
| ||||
| Ccm10gPort2PauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.23 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2)
| ||||
| Ccm10gPort2ReceiveStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.24 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of whether light is being received on the fiber port (port 2)
| ||||
| Ccm10gPortLoopBack | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.25 | INTEGER | RW | |
column · INTEGER · read-write · current Media converter module's current port loopback mode setting. Writing to this object will change the current settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm10gPortTestMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.26 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current port test mode setting.
| ||||
| Tcm10gConfigTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2 | NA | ||
table · not-accessible · current Table of CM-10G type media converter module's configuration type information. | ||||
| Rcm10gConfigEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-10G type media converter module. | ||||
| Ccm10gConfigSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-10G type module is currently inserted | ||||
| Ccm10gConfigStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.3 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| Ccm10gConfigModuleName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.4 | DisplayString (SIZE (0..63)) | RW | |
column · DisplayString (SIZE (0..63)) · read-write · current This object identifies a user configurable name for the media converter module present in the chassis. | ||||
| Ccm10gConfigLinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm10gConfigFiberFaultAlert | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.6 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigFiberAutoNeg | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.7 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the wither fiber auto-negotiation is enabled for both ports. This only applies if 1G SFP modules are in use. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort1Name | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.8 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for port 1. | ||||
| Ccm10gConfigPort1Enable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.9 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether port 1 is enabled. | ||||
| Ccm10gConfigPort1EdcMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.10 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the EDC mode for this port. This config option only applies for an SFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm10gConfigPort1FecEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.11 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies the whether FEC control is enabled for this port. This config option only applies for an XFP module. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort1FecAmplitude | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.12 | INTEGER (-128..127) | RW | |
column · INTEGER (-128..127) · read-write · current This object identifies the FEC Amplitude value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort1FecPhase | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.13 | INTEGER (-128..127) | RW | |
column · INTEGER (-128..127) · read-write · current This object identifies the FEC phase value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort1WavelengthEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.14 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether Wavelength fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort1WavelengthValue | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.15 | INTEGER (0..65535) | RW | |
column · INTEGER (0..65535) · read-write · current This object identifies Wavelength fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort1ChannelEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.16 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether channel number fine tuning is enabled for this port. This config option only applies for an XFP module. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort1ChannelNumber | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.17 | INTEGER (1..65535) | RW | |
column · INTEGER (1..65535) · read-write · current This object identifies the channel number fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort1TxDitherEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.18 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies the whether TX Dither control is enabled on this port. If not enabled the default TX Dither value will be used. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort1TxDitherValue | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.19 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the whether TX Dither is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort2Name | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.20 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for port 2. | ||||
| Ccm10gConfigPort2Enable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.21 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether port 2 is enabled. | ||||
| Ccm10gConfigPort2EdcMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.22 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the EDC mode for this port. This config option only applies for an SFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm10gConfigPort2FecEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.23 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies the whether FEC control is enabled for this port. This config option only applies for an XFP module. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort2FecAmplitude | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.24 | INTEGER (-128..127) | RW | |
column · INTEGER (-128..127) · read-write · current This object identifies the FEC Amplitude value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort2FecPhase | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.25 | INTEGER (-128..127) | RW | |
column · INTEGER (-128..127) · read-write · current This object identifies the FEC phase value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort2WavelengthEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.26 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether Wavelength fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort2WavelengthValue | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.27 | INTEGER (0..65535) | RW | |
column · INTEGER (0..65535) · read-write · current This object identifies Wavelength fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort2ChannelEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.28 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether channel number fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort2ChannelNumber | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.29 | INTEGER (1..65535) | RW | |
column · INTEGER (1..65535) · read-write · current This object identifies the channel number fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort2TxDitherEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.30 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies the whether TX Dither control is enabled on this port. If not enabled the default TX Dither value will be used. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gConfigPort2TxDitherValue | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.31 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the whether TX Dither is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Tcm10gLedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3 | NA | ||
table · not-accessible · current Table of CM-10G type media converter module's LED status information. | ||||
| Rcm10gLedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-10G type media converter module. | ||||
| Ccm10gLedsSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-10G type module is currently inserted | ||||
| Ccm10gLedPWR | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1.3 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the power (PWR) LED on the media converter module.
Possible status values are:
off(0) - No power to the module
onGreen(1) - Power being applied to module
blinking(2) - Loopback or Link-Test enabled
| ||||
| Ccm10gLedLK1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the port 1 link (LK1) LED on the
media converter module.
Possible status values are:
off(0) - No link
on(1) - Port link present
| ||||
| Ccm10gLedLK2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the port 2 link (LK2) LED on the
media converter module.
Possible status values are:
off(0) - No link
on(1) - Port link present
| ||||
| NexCM | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9 | |||
| TexCMTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1 | NA | ||
table · not-accessible · current Table of CM-1110 type media converter module's configuration and status type information. | ||||
| RexCMEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1110 type media converter module.
| ||||
| CexCMSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-1110 type module is currently inserted | ||||
| CexCMModelName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the model of media converter module present in the chassis | ||||
| CexCMModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the media converter module present in the chassis | ||||
| CexCMHwJmp5ConfigMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers.
| ||||
| CexCMHwSw1AutoLocalRemote | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for VDSL role.
| ||||
| CexCMHwSw2Rate | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for VDSL rate/reach.
| ||||
| CexCMHwSw3SymmetricAsymmetric | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for VDSL band plan.
| ||||
| CexCMHwSw4SnrRatio | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.9 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for VDSL signal-to-noise ratio.
| ||||
| CexCMHwSw5Loopback | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.10 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for VDSL loopback.
| ||||
| CexCMHwSw6EthAutoNeg | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for ethernet auto-negotiation.
| ||||
| CexCMHwSw7EthSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for ethernet speed (when auto-negotiation is disabled).
| ||||
| CexCMHwSw8EthDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.13 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for ethernet duplex (when auto-negotiation is disabled).
| ||||
| CexCMHwSw9LinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.14 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for link mode.
| ||||
| CexCMHwSw10InterlinkFaultFeedback | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.15 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for interlink fault feedback.
| ||||
| CexCMVdslLinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.16 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current VDSL link status.
| ||||
| CexCMVdslConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.17 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's VDSL port connector type.
| ||||
| CexCMVdslLoopBack | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.18 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| CexCMVdslRole | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.19 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the VDSL port's current role.
| ||||
| CexCMVdslProfile | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.20 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the VDSL port's current profile. This value has no meaning when the VDSL role is remote.
| ||||
| CexCMVdslBitswapping | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.21 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the VDSL port's current bitswapping status. This value has no meaning when the VDSL role is remote.
| ||||
| CexCMVdslStatusAttainableDataRateUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.22 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's attainable data rate (upstream) in kbps. | ||||
| CexCMVdslStatusAttainableDataRateDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.23 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's attainable data rate (downstream) in kbps. | ||||
| CexCMVdslStatusActualDataRateUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.24 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual data rate (upstream) in kbps. | ||||
| CexCMVdslStatusActualDataRateDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.25 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual data rate (downstream) in kbps. | ||||
| CexCMVdslStatusPrevDataRateUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.26 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's previous data rate (upstream) in kbps. | ||||
| CexCMVdslStatusPrevDataRateDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.27 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's previous data rate (downstream) in kbps. | ||||
| CexCMVdslStatusActualSnrUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.28 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal-to-noise ratio (upstream) in 0.1 dB. | ||||
| CexCMVdslStatusActualSnrDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.29 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal-to-noise ratio (downstream) in 0.1 dB. | ||||
| CexCMVdslStatusActualSnrUs0 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.30 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal-to-noise ratio (upstream 0) in 0.1 dB. | ||||
| CexCMVdslStatusActualSnrUs1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.31 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal-to-noise ratio (upstream 1) in 0.1 dB. | ||||
| CexCMVdslStatusActualSnrDs1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.32 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal-to-noise ratio (downstream 1) in 0.1 dB. | ||||
| CexCMVdslStatusActualSnrUs2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.33 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal-to-noise ratio (upstream 2) in 0.2 dB. | ||||
| CexCMVdslStatusActualSnrDs2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.34 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal-to-noise ratio (downstream 2) in 0.2 dB. | ||||
| CexCMVdslStatusActualSnrUs3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.35 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal-to-noise ratio (upstream 3) in 0.3 dB. | ||||
| CexCMVdslStatusActualSnrDs3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.36 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal-to-noise ratio (downstream 3) in 0.3 dB. | ||||
| CexCMVdslStatusActualSnrUs4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.37 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal-to-noise ratio (upstream 4) in 0.4 dB. | ||||
| CexCMVdslStatusActualSnrDs4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.38 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal-to-noise ratio (downstream 4) in 0.4 dB. | ||||
| CexCMVdslStatusActualSignalAttenuationUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.39 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal attenuation (upstream) in 0.1 dB. | ||||
| CexCMVdslStatusActualSignalAttenuationDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.40 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal attenuation (downstream) in 0.1 dB. | ||||
| CexCMVdslStatusActualSignalAttenuationUs0 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.41 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal attenuation (upstream 0) in 0.1 dB. | ||||
| CexCMVdslStatusActualSignalAttenuationUs1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.42 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal attenuation (upstream 1) in 0.1 dB. | ||||
| CexCMVdslStatusActualSignalAttenuationDs1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.43 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal attenuation (downstream 1) in 0.1 dB. | ||||
| CexCMVdslStatusActualSignalAttenuationUs2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.44 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal attenuation (upstream 2) in 0.2 dB. | ||||
| CexCMVdslStatusActualSignalAttenuationDs2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.45 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal attenuation (downstream 2) in 0.2 dB. | ||||
| CexCMVdslStatusActualSignalAttenuationUs3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.46 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal attenuation (upstream 3) in 0.3 dB. | ||||
| CexCMVdslStatusActualSignalAttenuationDs3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.47 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal attenuation (downstream 3) in 0.3 dB. | ||||
| CexCMVdslStatusActualSignalAttenuationUs4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.48 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal attenuation (upstream 4) in 0.4 dB. | ||||
| CexCMVdslStatusActualSignalAttenuationDs4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.49 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual signal attenuation (downstream 4) in 0.4 dB. | ||||
| CexCMVdslStatusActualLineAttenuationUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.50 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual line attenuation (upstream) in 0.1 dB. | ||||
| CexCMVdslStatusActualLineAttenuationDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.51 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual line attenuation (downstream) in 0.1 dB. | ||||
| CexCMVdslStatusActualLineAttenuationUs0 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.52 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual line attenuation (upstream 0) in 0.1 dB. | ||||
| CexCMVdslStatusActualLineAttenuationUs1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.53 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual line attenuation (upstream 1) in 0.1 dB. | ||||
| CexCMVdslStatusActualLineAttenuationDs1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.54 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual line attenuation (downstream 1) in 0.1 dB. | ||||
| CexCMVdslStatusActualLineAttenuationUs2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.55 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual line attenuation (upstream 2) in 0.2 dB. | ||||
| CexCMVdslStatusActualLineAttenuationDs2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.56 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual line attenuation (downstream 2) in 0.2 dB. | ||||
| CexCMVdslStatusActualLineAttenuationUs3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.57 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual line attenuation (upstream 3) in 0.3 dB. | ||||
| CexCMVdslStatusActualLineAttenuationDs3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.58 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual line attenuation (downstream 3) in 0.3 dB. | ||||
| CexCMVdslStatusActualLineAttenuationUs4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.59 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual line attenuation (upstream 4) in 0.4 dB. | ||||
| CexCMVdslStatusActualLineAttenuationDs4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.60 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual line attenuation (downstream 4) in 0.4 dB. | ||||
| CexCMVdslStatusActualInterleaveDelayUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.61 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual interleave delay (upstream) in ms. | ||||
| CexCMVdslStatusActualInterleaveDelayDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.62 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual interleave delay (downstream) in ms. | ||||
| CexCMVdslStatusActualInpUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.63 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual INP (impulse noise protection) (upstream). | ||||
| CexCMVdslStatusActualInpDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.64 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual INP (impulse noise protection) (downstream) in ms. | ||||
| CexCMVdslStatusActualInterleavingDepthUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.65 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual interleaving depth (upstream). | ||||
| CexCMVdslStatusActualInterleavingDepthDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.66 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual interleaving depth (impulse noise protection) (downstream) in ms. | ||||
| CexCMVdslStatusActualInterleavingBlockUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.67 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual interleaving block (upstream). | ||||
| CexCMVdslStatusActualInterleavingBlockDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.68 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual interleaving block (impulse noise protection) (downstream) in ms. | ||||
| CexCMVdslStatusActualTransmitPowerUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.69 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual transmit power (upstream) in 0.1 dBm. | ||||
| CexCMVdslStatusActualTransmitPowerDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.70 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's actual transmit power (downstream) in 0.1 dBm. | ||||
| CexCMVdslStatusMaxDataRateUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.71 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's maximum data rate (upstream) in kbps. | ||||
| CexCMVdslStatusMaxDataRateDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.72 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's maximum data rate (downstream) in kbps. | ||||
| CexCMVdslStatusMinDataRateUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.73 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's minimum data rate (upstream) in kbps. | ||||
| CexCMVdslStatusMinDataRateDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.74 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's minimum data rate (downstream) in kbps. | ||||
| CexCMVdslStatusTargetSnrUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.75 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's target signal-to-noise ratio (upstream) in 0.1 dB. | ||||
| CexCMVdslStatusTargetSnrDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.76 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's target signal-to-noise ratio (downstream) in 0.1 dB. | ||||
| CexCMVdslStatusMaxInterleaveDelayUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.77 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's maximum interleave delay (upstream) in ms. | ||||
| CexCMVdslStatusMaxInterleaveDelayDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.78 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's maximum interleave delay (downstream) in ms. | ||||
| CexCMVdslStatusMinInpUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.79 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's minimum INP (impulse noise protection) (upstream). | ||||
| CexCMVdslStatusMinInpDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.80 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the VDSL port's minimum INP (impulse noise protection) (downstream) in ms. | ||||
| CexCMVdslRemoteLoopback | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.81 | INTEGER | RW | |
column · INTEGER · read-write · current Write remoteLoopbackOff(1) or remoteLoopbackOn(2) to this object to set the loopback state of the remote VDSL peer. This object's value represents the last loopback command sent to the peer.
| ||||
| CexCMVdslRemoteReset | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.82 | INTEGER | RW | |
column · INTEGER · read-write · current Write resetRemotePeer(1) to this object to reset the remote VDSL peer. This object's value has no meaning
| ||||
| CexCMEthernetLinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.83 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current Ethernet link status.
| ||||
| CexCMEthernetConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.84 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's Ethernet connector type.
| ||||
| CexCMEthernetAutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.85 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current Ethernet auto-negotiation state.
| ||||
| CexCMEthernetSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.86 | INTEGER | RO | |
column · INTEGER · read-only · current If Ethernet auto-negotiation state is complete then this object indicates the media converter module's current Ethernet auto-negotiated speed setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| CexCMEthernetDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.87 | INTEGER | RO | |
column · INTEGER · read-only · current If Ethernet auto-negotiation state is complete then this object indicates the media converter module's current Ethernet auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| CexCMEthernetCrossOver | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.88 | INTEGER | RO | |
column · INTEGER · read-only · current If Ethernet auto-negotiation state is complete then this object indicates the media converter module's current Ethernet auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| CexCMEthernetPauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.89 | INTEGER | RO | |
column · INTEGER · read-only · current If Ethernet auto-negotiation state is complete then this object indicates the media converter module's current Ethernet auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| CexCMEthernetLPRFStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.90 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's Ethernet Link Partner Remote Fault status.
| ||||
| CexCMEthernetAutoSpeedDownshift | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.91 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the Ethernet auto speed downshift feature. noDownshift indicates that an automatic downshift of the Ethernet speed has not occurred.
| ||||
| CexCMEthernetMDI | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.92 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the Ethernet port's crossover status: MDI or MDI-X.
| ||||
| CexCMVdslFirmwareVersion | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.93 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the version of the VDSL firmware. | ||||
| CexCMVdslFirmwareDate | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.94 | DateAndTime | RO | |
column · DateAndTime · read-only · current This object identifies the date of the VDSL firmware | ||||
| CexCMVdslFirmwareDateString | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.95 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the version of the VDSL firmware, in human-readable format. | ||||
| TexCMConfigTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2 | NA | ||
table · not-accessible · current Table of CM-1110 type media converter module's configuration type information. | ||||
| RexCMConfigEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1110 type media converter module. | ||||
| CexCMConfigSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the ex-CM type module is currently inserted | ||||
| CexCMConfigStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.3 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| CexCMConfigModuleName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.4 | DisplayString (SIZE (0..63)) | RW | |
column · DisplayString (SIZE (0..63)) · read-write · current This object identifies a user configurable name for the media converter module present in the chassis. | ||||
| CexCMConfigLinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| CexCMConfigInterlinkFaultFeedback | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.6 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the interlink fault feedback setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| CexCMConfigVdslPortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.7 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the VDSL port. | ||||
| CexCMConfigVdslPortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.8 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the VDSL port is enabled. | ||||
| CexCMConfigVdslProfileMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.9 | INTEGER | RW | |
column · INTEGER · read-write · current This object specifies how the VDSL profile is selected. Auto: select through exCMConfigVdslRate and exCMConfigVdslSymmetry Manual: select through exCMConfigVdslProfile.
| ||||
| CexCMConfigVdslRole | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.10 | INTEGER | RW | |
column · INTEGER · read-write · current This object specifies the VDSL role: auto, local (CO), or remote (CPE).
| ||||
| CexCMConfigVdslRate | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.11 | INTEGER | RW | |
column · INTEGER · read-write · current This object specifies the VDSL rate/reach.
| ||||
| CexCMConfigVdslSymmetry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.12 | INTEGER | RW | |
column · INTEGER · read-write · current This object specifies the VDSL band plan or symmetry.
| ||||
| CexCMConfigVdslProfile | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.13 | INTEGER | RW | |
column · INTEGER · read-write · current This object specifies the VDSL profile.
| ||||
| CexCMConfigVdslOverrideProfile | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.14 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object specifies whether to override advanced VDSL profile settings (e.g exCMConfigVdslSignalToNoiseRatioUp). | ||||
| CexCMConfigVdslSignalToNoiseRatioUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.15 | Integer32 (30..240) | RW | |
column · Integer32 (30..240) · read-write · current This object represents the advanced VDSL profile setting signal-to-noise ratio (upstream) in 0.1 dB. | ||||
| CexCMConfigVdslMinDataRateUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.16 | Integer32 (128..101064) | RW | |
column · Integer32 (128..101064) · read-write · current This object represents the advanced VDSL profile setting minimum data rate (upstream) in kbps. | ||||
| CexCMConfigVdslMaxDataRateUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.17 | Integer32 (128..101064) | RW | |
column · Integer32 (128..101064) · read-write · current This object represents the advanced VDSL profile setting maximum data rate (upstream) in kbps. | ||||
| CexCMConfigVdslMaxInterleaveDelayUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.18 | Integer32 (0..16) | RW | |
column · Integer32 (0..16) · read-write · current This object represents the advanced VDSL profile setting maximum delay (upstream) in ms. | ||||
| CexCMConfigVdslMinInpUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.19 | Integer32 (1..18) | RW | |
column · Integer32 (1..18) · read-write · current This object represents the advanced VDSL profile setting minimum INP (impulse noise protection) (upstream). | ||||
| CexCMConfigVdslSignalToNoiseRatioDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.20 | Integer32 (30..240) | RW | |
column · Integer32 (30..240) · read-write · current This object represents the advanced VDSL profile setting signal-to-noise ratio (downstream) in 0.1 dB. | ||||
| CexCMConfigVdslMinDataRateDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.21 | Integer32 (128..101064) | RW | |
column · Integer32 (128..101064) · read-write · current This object represents the advanced VDSL profile setting minimum data rate (downstream) in kbps. | ||||
| CexCMConfigVdslMaxDataRateDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.22 | Integer32 (128..101064) | RW | |
column · Integer32 (128..101064) · read-write · current This object represents the advanced VDSL profile setting maximum data rate (downstream) in kbps. | ||||
| CexCMConfigVdslMaxInterleaveDelayDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.23 | Integer32 (0..16) | RW | |
column · Integer32 (0..16) · read-write · current This object represents the advanced VDSL profile setting maximum delay (downstream) in ms. | ||||
| CexCMConfigVdslMinInpDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.24 | Integer32 (1..18) | RW | |
column · Integer32 (1..18) · read-write · current This object represents the advanced VDSL profile setting minimum INP (impulse noise protection) (downstream). | ||||
| CexCMConfigVdslBitswapping | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.25 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object represents the advanced VDSL profile setting bitswapping. | ||||
| CexCMConfigVdslLowBandwidthAlarmUp | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.26 | Integer32 (0..90000) | RW | |
column · Integer32 (0..90000) · read-write · current This object represents the VDSL low bandwidth alarm threshold (upstream) in kbps. | ||||
| CexCMConfigVdslLowBandwidthAlarmDown | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.27 | Integer32 (0..90000) | RW | |
column · Integer32 (0..90000) · read-write · current This object represents the VDSL low bandwidth alarm threshold (downstream) in kbps. | ||||
| CexCMConfigEthernetPortName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.28 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for the ethernet port. | ||||
| CexCMConfigEthernetPortEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.29 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether the VDSL port is enabled. | ||||
| CexCMConfigEthernetAutoNegotiation | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.30 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the whether ethernet auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| CexCMConfigEthernetAutoNegAdv10HDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.31 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the ethernet port advertises willingness to connect at 10Mbps, half duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| CexCMConfigEthernetAutoNegAdv10FDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.32 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the ethernet port advertises willingness to connect at 10Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| CexCMConfigEthernetAutoNegAdv100HDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.33 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the ethernet port advertises willingness to connect at 100Mbps, half duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| CexCMConfigEthernetAutoNegAdv100FDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.34 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the ethernet port advertises willingness to connect at 100Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| CexCMConfigEthernetAutoNegAdv1000FDX | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.35 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object controls whether or the ethernet port advertises willingness to connect at 1000Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | ||||
| CexCMConfigEthernetSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.36 | INTEGER | RW | |
column · INTEGER · read-write · current If ethernet auto-negotiation is disabled then this object identifies the configured cooper speed. 1000 Mbps speed can only be auto negotiated. If ethernet auto-negotiation is enabled then this object is ignored. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| CexCMConfigEthernetDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.37 | INTEGER | RW | |
column · INTEGER · read-write · current If ethernet auto-negotiation is disabled then this object identifies the duplex setting for 10 & 100 Mbps for the ethernet port. Duplex for 1000 Mbps has to be auto negotiated. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| CexCMConfigEthernetCrossOver | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.38 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the ethernet MDI/MDI-X setting.This object is read-only if the media converter module's ConfigMode jumper is set to
| ||||
| CexCMConfigEthernetPauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.39 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the ethernet pause (flow control) setting that is a advertised. The settings can be disabled, advertise symmetrical, advertise asymmetrical TX or advertise symmetrical and asymmetrical RX. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| CexCMConfigEthernetAutoSpeedDownshift | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.40 | INTEGER (0..8) | RW | |
column · INTEGER (0..8) · read-write · current This object identifies the number of times the PHY attempts to establish a Gigabit link before the PHY downshift to the next highest speed. A value of 0 indicates the auto downshift is disabled | ||||
| CexCMConfigEthernet10BaseTDistance | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.41 | INTEGER | RW | |
column · INTEGER · read-write · current When using cable exceeding 100 meters in 10BASE-T mode this feature should be set to extended(1).
| ||||
| CexCMConfigUnidirectionalEthernet | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.42 | INTEGER | RW | |
column · INTEGER · read-write · current Restrict the flow of Ethernet traffic to a single direction. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).
| ||||
| CexCMConfigPriorityToEgressQueueMap0 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.43 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigPriorityToEgressQueueMap1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.44 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigPriorityToEgressQueueMap2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.45 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigPriorityToEgressQueueMap3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.46 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigPriorityToEgressQueueMap4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.47 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigPriorityToEgressQueueMap5 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.48 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigPriorityToEgressQueueMap6 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.49 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigPriorityToEgressQueueMap7 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.50 | INTEGER (0..3) | RW | |
column · INTEGER (0..3) · read-write · current Set the egress queue of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernet8021pPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.51 | OnOffValue | RW | |
column · OnOffValue · read-write · current Use 802.1p tag priority. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetIpTosPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.52 | OnOffValue | RW | |
column · OnOffValue · read-write · current Use IP TOS priority. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetPriorityPrecedence | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.53 | INTEGER | RW | |
column · INTEGER · read-write · current Configure priority precedence. (This feature may require a media converter module firmware upgrade).
| ||||
| CexCMConfigEthernetCongestionPolicy | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.54 | INTEGER | RW | |
column · INTEGER · read-write · current Configure priority congestion policy. (This feature may require a media converter module firmware upgrade).
| ||||
| CexCMConfigEthernetPriorityMap0 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.55 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetPriorityMap1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.56 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetPriorityMap2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.57 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetPriorityMap3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.58 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetPriorityMap4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.59 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetPriorityMap5 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.60 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetPriorityMap6 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.61 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetPriorityMap7 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.62 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetIngressLimit | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.63 | INTEGER | RW | |
column · INTEGER · read-write · current Set a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade).
| ||||
| CexCMConfigEthernetEgressLimit | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.64 | INTEGER | RW | |
column · INTEGER · read-write · current Set a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade).
| ||||
| CexCMConfigEthernetDiscardTaggedFrames | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.65 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable discarding of tagged frames. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetDiscardUntaggedFrames | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.66 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable discarding of untagged frames. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetDefaultVlanId | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.67 | INTEGER (0..4095) | RW | |
column · INTEGER (0..4095) · read-write · current Set the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetDefaultPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.68 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Set the default frame priority. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetVlanTaggingAction | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.69 | INTEGER | RW | |
column · INTEGER · read-write · current Set the default tagging action. (This feature may require a media converter module firmware upgrade).
| ||||
| CexCMConfigEthernetFilterUnknownMulticast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.70 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigEthernetFilterUnknownUnicast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.71 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdsl8021pPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.72 | OnOffValue | RW | |
column · OnOffValue · read-write · current Use 802.1p tag priority. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslIpTosPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.73 | OnOffValue | RW | |
column · OnOffValue · read-write · current Use IP TOS priority. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslPriorityPrecedence | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.74 | INTEGER | RW | |
column · INTEGER · read-write · current Configure priority precedence. (This feature may require a media converter module firmware upgrade).
| ||||
| CexCMConfigVdslCongestionPolicy | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.75 | INTEGER | RW | |
column · INTEGER · read-write · current Configure priority congestion policy. (This feature may require a media converter module firmware upgrade).
| ||||
| CexCMConfigVdslPriorityMap0 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.76 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslPriorityMap1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.77 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslPriorityMap2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.78 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslPriorityMap3 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.79 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslPriorityMap4 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.80 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslPriorityMap5 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.81 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslPriorityMap6 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.82 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslPriorityMap7 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.83 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslIngressLimit | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.84 | INTEGER | RW | |
column · INTEGER · read-write · current Set a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade).
| ||||
| CexCMConfigVdslEgressLimit | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.85 | INTEGER | RW | |
column · INTEGER · read-write · current Set a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade).
| ||||
| CexCMConfigVdslDiscardTaggedFrames | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.86 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable discarding of tagged frames. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslDiscardUntaggedFrames | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.87 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable discarding of untagged frames. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslDefaultVlanId | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.88 | INTEGER (0..4095) | RW | |
column · INTEGER (0..4095) · read-write · current Set the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslDefaultPriority | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.89 | INTEGER (0..7) | RW | |
column · INTEGER (0..7) · read-write · current Set the default frame priority. (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslVlanTaggingAction | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.90 | INTEGER | RW | |
column · INTEGER · read-write · current Set the default tagging action. (This feature may require a media converter module firmware upgrade).
| ||||
| CexCMConfigVdslFilterUnknownMulticast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.91 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslFilterUnknownUnicast | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.92 | OnOffValue | RW | |
column · OnOffValue · read-write · current Enable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | ||||
| CexCMConfigVdslFastMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.93 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object represents the VDSL fast mode setting. | ||||
| TexCMLedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3 | NA | ||
table · not-accessible · current Table of CM-1110 type media converter module's LED status information. | ||||
| RexCMLedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1110 type media converter module. | ||||
| CexCMLedSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number of the module | ||||
| CexCMLedILNK | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.3 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the ILNK (InterLink) LED on the media converter module.
Possible status values are:
slowBlinkingGreen(1) - ILNK port is idle or handshaking
fastBlinkingGreen(2) - ILNK port is training
green(3) - ILNK port is up
| ||||
| CexCMLedLOC | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the Local (LOC) LED on the media converter module. When this LED is green, it indicates that the InterLink port's VDSL role is local.
| ||||
| CexCMLedPWR | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the power (PWR) LED on the media converter module.
Possible status values are:
off(0) - No power to the module
onGreen(1) - Power being applied to module
blinking(2) - InterLink loopback enabled
| ||||
| CexCMLedETH | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the ETH (Ethernet) LED on the media converter module.
Possible status values are:
off(0) - ETH port is down
slowBlinkingGreen(1) - ETH port is down, due to the VDSL port or peer copper ethernet port being down
green(2) - ETH port is up
| ||||
| CexCMLedRMT | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the Remote (RMT) LED on the media converter module. When this LED is green, it indicates that the InterLink port's VDSL role is remote.
| ||||
| TexCMStatsTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4 | NA | ||
table · not-accessible · current Table of CM-1110 type media converter module's configuration and status type information. | ||||
| RexCMStatsEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1110 type media converter module. | ||||
| CexCMStatsSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the ex-1CM type module is currently inserted | ||||
| CexCMMediaPortIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.3 | INTEGER (1..2) | NA | |
column · INTEGER (1..2) · not-accessible · current Media converter module port index indicating which media port the statistical counters are associated with. | ||||
| CexCMPortInDiscards | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.4 | Counter32 | RO | |
column · Counter32 · read-only · current A counter that counts the number of good, non-filtered frames that normally would have been forwarded, but could not due to lack of buffer space. | ||||
| CexCMPortInFiltered | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.5 | INTEGER (0..65535) | RO | |
column · INTEGER (0..65535) · read-only · current A counter that counts the number of good frames that were filtered due to ingress switch policy rules. | ||||
| CexCMPortInGoodOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.6 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that is the sum of lengths of all good Ethernet frames received on the media port. | ||||
| CexCMPortHCInGoodOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.7 | Counter64 | RO | |
column · Counter64 · read-only · current An ingress counter that is the sum of lengths of all good Ethernet frames received on the media port. This object is a 64-bit version of exCMPortInGoodOctets. | ||||
| CexCMPortInBadOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.8 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that is the sum of lengths of all bad Ethernet frames received on the media port.. | ||||
| CexCMPortInUnicasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.9 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of good frames received that have a Unicast destination MAC address. | ||||
| CexCMPortInBroadcasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.10 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of good frames received that have a Broadcast destination MAC address. | ||||
| CexCMPortInMulticasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.11 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of good frames received that have a Multicast destination MAC address. This count does not include frames counted in the exCMPortInPauses or the exCMPortInBroadcasts objects. | ||||
| CexCMPortInPauses | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.12 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of good frames reachieved that have a Pause destination MAC address. | ||||
| CexCMPortInUnderSizes | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.13 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a length less that 64 octets but with a valid FCS. | ||||
| CexCMPortInFragments | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.14 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a length less that 64 octets and an invalid FCS. | ||||
| CexCMPortInOversizes | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.15 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a length more than the maximum packet size but with a valid FCS. The maximum packet size can be set using the exCMConfigMaxPacketsSize object. | ||||
| CexCMPortInJabbers | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.16 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a length more than the maximum packet size but with a invalid FCS. The maximum packet size can be set using the exCMConfigMaxPacketsSize object. | ||||
| CexCMPortInRxErrs | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.17 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with an RxErr signal from the PHY. | ||||
| CexCMPortInFcsErrs | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.18 | Counter32 | RO | |
column · Counter32 · read-only · current An ingress counter that counts the number of frames received with a CRC error not counted in the exCMPortInFragments, exCMPortInFcsErr, or the exCMPortInRxErr objects. | ||||
| CexCMPortPkts64Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.19 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of exactly 64 Octets, including those with errors. | ||||
| CexCMPortPkts65to127Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.20 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 65 and 127 Octets inclusive, including those with errors. | ||||
| CexCMPortPkts128to255Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.21 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 128 and 255 Octets inclusive, including those with errors. | ||||
| CexCMPortPkts256to511Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.22 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 256 and 511 Octets inclusive, including those with errors. | ||||
| CexCMPortPkts512to1023Octets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.23 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 512 and 1023 Octets inclusive, including those with errors. | ||||
| CexCMPortPkts1024toMaxOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.24 | Counter32 | RO | |
column · Counter32 · read-only · current A Histogram counter that counts the number of frames received and transmitted with a length of between 1024 and maximum packet size octets inclusive, including those with errors. The maximum packet size can be set using the exCMConfigMaxPacketsSize object. | ||||
| CexCMPortOutOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.25 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port. | ||||
| CexCMPortHCOutOctets | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.26 | Counter64 | RO | |
column · Counter64 · read-only · current An Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port. This object is a 64-bit version of exCMPortOutOctets. | ||||
| CexCMPortOutFiltered | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.27 | INTEGER (0..65535) | RO | |
column · INTEGER (0..65535) · read-only · current A counter that counts the number of good frames that were filtered due to egress switch policy rules. | ||||
| CexCMPortOutUnicasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.28 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of good frames sent that have a Unicast destination MAC address. | ||||
| CexCMPortOutBroadcasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.29 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of good frames sent that have a Broadcast destination MAC address. | ||||
| CexCMPortOutMulticasts | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.30 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of good frames sent that have a Multicast destination MAC address. This count does not include frames counted in the exCMPortOutPauses or the exCMPortOutBroadcasts objects. | ||||
| CexCMPortOutPauses | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.31 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of good frames reachieved that have a Pause destination MAC address. | ||||
| CexCMPortDeferreds | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.32 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of successfully transmitted frames that experienced no collisions but are delayed because the medium was busy during the first attempt. This counter is applicable in half-duplex only. | ||||
| CexCMPortCollisions | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.33 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of collision events seen by the MAC not including those counted in exCMPortSingles, exCMPortMultiple , exCMPortExcessives or exCMPortLates objects. This counter is applicable in half-duplex only. | ||||
| CexCMPortSingles | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.34 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of successfully transmitted frames that experienced exactly one collision. This counter is applicable in half-duplex only. | ||||
| CexCMPortMultiples | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.35 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number of successfully transmitted frames that experienced more than one collision. This counter is aplicable in half-duplex only. | ||||
| CexCMPortExcessives | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.36 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number frames dropped in the transmit MAC because the frame experienced 16 consecutive collisions. This counter is applicable in half-duplex only. | ||||
| CexCMPortLates | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.37 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number times a collision is detected later than 512 bits-times into the transmission of a frame. This counter is applicable in half-duplex only. | ||||
| CexCMPortOutFcsErrs | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.38 | Counter32 | RO | |
column · Counter32 · read-only · current An Egress counter that counts the number frames transmitted with an invalid FCS. | ||||
| CexCMPortResetCounters | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.39 | YesNoValue | RW | |
column · YesNoValue · read-write · current Allows the resetting of all exCMStats statistical counters for this port. | ||||
| TexCMVdslStatsTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5 | NA | ||
table · not-accessible · current Table of CM-1110 type media converter module's configuration and status type information. | ||||
| RexCMVdslStatsEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-1110 type media converter module. | ||||
| CexCMVdslStatsSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the ex-1CM type module is currently inserted | ||||
| CexCMVdslStatsMediaPortIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.3 | Unsigned32 | NA | |
column · Unsigned32 · not-accessible · current Media converter module port index indicating which media port the statistical counters are associated with. | ||||
| CexCMVdslStatsTimePeriod | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module port index indicating which media port the statistical counters are associated with.
| ||||
| CexCMVdslStatsFullInitLocal | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.5 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's fully initialized (local) count. | ||||
| CexCMVdslStatsCodeViolationLocal | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.6 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's code violation (local) count. | ||||
| CexCMVdslStatsCorrectedLocal | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.7 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's corrected (local) count. | ||||
| CexCMVdslStatsFecSecsLocal | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.8 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's forward error correction seconds (local) count. | ||||
| CexCMVdslStatsErroredSecsLocal | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.9 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's errored seconds (local) count. | ||||
| CexCMVdslStatsSeverelyErroredSecsLocal | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.10 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's severely errored seconds (local) count. | ||||
| CexCMVdslStatsLossOfSignalSecsLocal | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.11 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's loss of signal seconds (local) count. | ||||
| CexCMVdslStatsUnavailableSecsLocal | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.12 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's unavailable seconds (local) count. | ||||
| CexCMVdslStatsTimeElapsedLocal | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.13 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's elapsed time in seconds (local) count. | ||||
| CexCMVdslStatsFullInitRemote | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.14 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's fully initialized (remote) count. | ||||
| CexCMVdslStatsCodeViolationRemote | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.15 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's code violation (remote) count. | ||||
| CexCMVdslStatsCorrectedRemote | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.16 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's corrected (remote) count. | ||||
| CexCMVdslStatsFecSecsRemote | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.17 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's forward error correction seconds (remote) count. | ||||
| CexCMVdslStatsErroredSecsRemote | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.18 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's errored seconds (remote) count. | ||||
| CexCMVdslStatsSeverelyErroredSecsRemote | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.19 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's severely errored seconds (remote) count. | ||||
| CexCMVdslStatsLossOfSignalSecsRemote | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.20 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's loss of signal seconds (remote) count. | ||||
| CexCMVdslStatsUnavailableSecsRemote | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.21 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's unavailable seconds (remote) count. | ||||
| CexCMVdslStatsTimeElapsedRemote | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.22 | Integer32 | RO | |
column · Integer32 · read-only · current The VDSL port's elapsed time in seconds (remote) count. | ||||
| TexCMAvctTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6 | NA | ||
table · not-accessible · current Table of ex-CM media converter modules. | ||||
| RexCMAvctEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a copper Ethernet port on the eX-CM type media converter module. | ||||
| CexCMAvctSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the eX-CM type module is currently inserted | ||||
| CexCMAvctStart | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.3 | YesNoValue | RW | |
column · YesNoValue · read-write · current Set this self-clearing variable to yes initiate the Advanced Virtual Cable Test. Note: During the test, no network data will be passed. | ||||
| CexCMAvctStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the state of the Advanced Virtual Cable Tester.
| ||||
| CexCMAvctTxRxPair1Results | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current Test result code returned from Virtual Cable Test of the Tx/Rx pair one.
| ||||
| CexCMAvctTxRxPair1Amplitude | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.6 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Amplitude of Tx/Rx pair one in millivolts when test result codes is short or open. | ||||
| CexCMAvctTxRxPair1Distance | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.7 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Distance in meters to fault when test result codes for Tx/Rx pair one is short or open. | ||||
| CexCMAvctTxRxPair2Results | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Test result code returned from Virtual Cable Test of the Tx/Rx pair two.
| ||||
| CexCMAvctTxRxPair2Amplitude | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.9 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Amplitude of Tx/Rx pair two in millivolts when test result codes is short or open. | ||||
| CexCMAvctTxRxPair2Distance | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.10 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Distance in meters to fault when test result codes for Tx/Rx pair two is short or open. | ||||
| CexCMAvctTxRxPair3Results | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current Test result code returned from Virtual Cable Test of the Tx/Rx pair three.
| ||||
| CexCMAvctTxRxPair3Amplitude | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.12 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Amplitude of Tx/Rx pair three in millivolts when test result codes is short or open. | ||||
| CexCMAvctTxRxPair3Distance | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.13 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Distance in meters to fault when test result codes for Tx/Rx pair three is short or open. | ||||
| CexCMAvctTxRxPair4Results | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.14 | INTEGER | RO | |
column · INTEGER · read-only · current Test result code returned from Virtual Cable Test of Tx/Rx pair four.
| ||||
| CexCMAvctTxRxPair4Amplitude | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.15 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Amplitude of Tx/Rx pair four in millivolts when test result codes is short or open. | ||||
| CexCMAvctTxRxPair4Distance | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.16 | DisplayString (SIZE (0..20)) | RO | |
column · DisplayString (SIZE (0..20)) · read-only · current Distance in meters to fault when test result codes for Tx/Rx pair four is short or open. | ||||
| Ncm10gt | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10 | |||
| Tcm10gtTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1 | NA | ||
table · not-accessible · current Table of CM-10G type media converter module's status type information. | ||||
| Rcm10gtEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-10G type media converter module. | ||||
| Ccm10gtSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-10G type module is currently inserted | ||||
| Ccm10gtModelname | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the model of media converter module present in the chassis | ||||
| Ccm10gtModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the media converter module present in the chassis | ||||
| Ccm10gtHwJmp5ConfigMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers.
| ||||
| Ccm10gtHwSw1OperationMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for operation mode. Data mode is for normal data transmission.
| ||||
| Ccm10gtHwSw2LinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Link Mode. If the Operation switch is set to Test, then this object indicates whether the port is in loopback or performing the build in link-test.
| ||||
| Ccm10gtHwSw3FiberFaultAlert | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Fiber Fault Alert. If the Operation switch is set to Test, then this object indicates which port is in test mode
| ||||
| Ccm10gtHwSw4EnergyEfficentEthernet | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.9 | INTEGER | RO | |
column · INTEGER · read-only · current This object indicates the current switch setting for Energy Efficient Ethernet on port 2.
| ||||
| Ccm10gtHwSw5Unused | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.10 | INTEGER | RO | |
column · INTEGER · read-only · current This object indicates the current switch setting for dip switch 5, which is unused.
| ||||
| Ccm10gtPort1LinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status (port 1).
| ||||
| Ccm10gtPort1ConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type (port 1).
| ||||
| Ccm10gtPort1AutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.13 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber auto-negotiation state (port 1).
| ||||
| Ccm10gtPort1Speed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.14 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port speed in megabits per second (port 1).
| ||||
| Ccm10gtPort1Duplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.15 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1)
| ||||
| Ccm10gtPort1PauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.16 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1)
| ||||
| Ccm10gtPort1ReceiveStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.17 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of whether light is being received on the fiber port (port 1)
| ||||
| Ccm10gtPort1LPRFStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.18 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's Link Partner Remote Fault status (port 1). This object only applies to SFP modules running at 1G, with auto-negotiation enabled.
| ||||
| Ccm10gtPort2LinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.19 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status (port 2).
| ||||
| Ccm10gtPort2ConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.20 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type (port 2).
| ||||
| Ccm10gtPort2AutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.21 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber auto-negotiation state (port 2).
| ||||
| Ccm10gtPort2Speed | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.22 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port speed in megabits per second (port 2).
| ||||
| Ccm10gtPort2Duplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.23 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2)
| ||||
| Ccm10gtPort2PauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.24 | INTEGER | RO | |
column · INTEGER · read-only · current If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2)
| ||||
| Ccm10gtPort2LPRFStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.25 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's copper Link Partner Remote Fault status.
| ||||
| Ccm10gtPortLoopBack | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.26 | INTEGER | RW | |
column · INTEGER · read-write · current Media converter module's current port loopback mode setting. Writing to this object will change the current settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm10gtPortTestMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.27 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current port test mode setting.
| ||||
| Tcm10gtConfigTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2 | NA | ||
table · not-accessible · current Table of CM-10G type media converter module's configuration type information. | ||||
| Rcm10gtConfigEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-10G type media converter module. | ||||
| Ccm10gtConfigSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-10G type module is currently inserted | ||||
| Ccm10gtConfigStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.3 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| Ccm10gtConfigModuleName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.4 | DisplayString (SIZE (0..63)) | RW | |
column · DisplayString (SIZE (0..63)) · read-write · current This object identifies a user configurable name for the media converter module present in the chassis. | ||||
| Ccm10gtConfigLinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm10gtConfigFiberFaultAlert | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.6 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gtConfigFiberAutoNeg | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.7 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the wither fiber auto-negotiation is enabled for both ports. This only applies if 1G SFP modules are in use. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gtConfigPort1Name | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.8 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for port 1. | ||||
| Ccm10gtConfigPort1Enable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.9 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether port 1 is enabled. | ||||
| Ccm10gtConfigPort1FecEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.10 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies the whether FEC control is enabled for this port. This config option only applies for an XFP module. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gtConfigPort1FecAmplitude | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.11 | INTEGER (-128..127) | RW | |
column · INTEGER (-128..127) · read-write · current This object identifies the FEC Amplitude value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gtConfigPort1FecPhase | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.12 | INTEGER (-128..127) | RW | |
column · INTEGER (-128..127) · read-write · current This object identifies the FEC phase value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gtConfigPort1WavelengthEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.13 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether Wavelength fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gtConfigPort1WavelengthValue | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.14 | INTEGER (0..65535) | RW | |
column · INTEGER (0..65535) · read-write · current This object identifies Wavelength fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gtConfigPort1ChannelEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.15 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether channel number fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gtConfigPort1ChannelNumber | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.16 | INTEGER (1..65535) | RW | |
column · INTEGER (1..65535) · read-write · current This object identifies the channel number fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gtConfigPort1TxDitherEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.17 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies the whether TX Dither control is enabled on this port. If not enabled the default TX Dither value will be used. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gtConfigPort1TxDitherValue | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.18 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the whether TX Dither is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm10gtConfigPort2Name | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.19 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for port 2. | ||||
| Ccm10gtConfigPort2Enable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.20 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether port 2 is enabled. | ||||
| Ccm10gtConfigPort2CopperDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.21 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the duplex settings for the copper port.
| ||||
| Ccm10gtConfigPort2CopperPauseEnh | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.22 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the copper pause (flow control) setting that is a advertised. The settings can be disabled, advertise symmetrical, advertise asymmetrical TX or advertise symmetrical and asymmetrical RX.
| ||||
| Ccm10gtConfigPort2CopperEnergyEfficientEthernet | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.23 | OnOffValue | RW | |
column · OnOffValue · read-write · current This object identifies the copper Energy-Efficient Ethernet setting for the media converter module present in the chassis. | ||||
| Tcm10gtLedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3 | NA | ||
table · not-accessible · current Table of CM-10G type media converter module's LED status information. | ||||
| Rcm10gtLedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-10G type media converter module. | ||||
| Ccm10gtLedsSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1.2 | SlotNumber | RO | |
column · SlotNumber · read-only · current The Slot number the CM-10G type module is currently inserted | ||||
| Ccm10gtLedPWR | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1.3 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the power (PWR) LED on the media converter module.
Possible status values are:
off(0) - No power to the module
onGreen(1) - Power being applied to module
blinking(2) - Loopback or Link-Test enabled
| ||||
| Ccm10gtLedLK1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the port 1 link (LK1) LED on the
media converter module.
Possible status values are:
off(0) - No link
on(1) - Port link present
| ||||
| Ccm10gtLedLK2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the port 2 link (LK2) LED on the
media converter module.
Possible status values are:
off(0) - No link
on(1) - Port link present
| ||||
| Ncm4gpt | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11 | |||
| Tcm4gptTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1 | NA | ||
table · not-accessible · current Table of CM-4GPT type media converter module's status type information. | ||||
| Rcm4gptEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-4GPT type media converter module. | ||||
| Ccm4gptSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-4GPT type module is currently inserted | ||||
| Ccm4gptModelname | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the model of media converter module present in the chassis | ||||
| Ccm4gptModelDesc | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies a static description of the media converter module present in the chassis | ||||
| Ccm4gptHwJmp5ConfigMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers.
| ||||
| Ccm4gptHwSw1LinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Link Mode.
| ||||
| Ccm4gptHwSw2FiberFaultAlert | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Fiber Fault Alert.
| ||||
| Ccm4gptHwSw3RateSelect | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current switch setting for Rate Select.
| ||||
| Ccm4gptHwSw4Unused | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.9 | INTEGER | RO | |
column · INTEGER · read-only · current This object indicates the current switch setting for the 4th, unused switch.
| ||||
| Ccm4gptPort1LinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.10 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status (port 1).
| ||||
| Ccm4gptPort1ConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type (port 1).
| ||||
| Ccm4gptPort2LinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's current fiber link status (port 2).
| ||||
| Ccm4gptPort2ConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.13 | INTEGER | RO | |
column · INTEGER · read-only · current Media converter module's fiber port connector type (port 2).
| ||||
| Tcm4gptConfigTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2 | NA | ||
table · not-accessible · current Table of CM-4GPT type media converter module's configuration type information. | ||||
| Rcm4gptConfigEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-4GPT type media converter module. | ||||
| Ccm4gptConfigSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-4GPT type module is currently inserted | ||||
| Ccm4gptConfigStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.3 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| Ccm4gptConfigModuleName | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.4 | DisplayString (SIZE (0..63)) | RW | |
column · DisplayString (SIZE (0..63)) · read-write · current This object identifies a user configurable name for the media converter module present in the chassis. | ||||
| Ccm4gptConfigLinkMode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm4gptConfigFiberFaultAlert | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.6 | EnableDisableValue | RW | |
column · EnableDisableValue · read-write · current This object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | ||||
| Ccm4gptConfigRateSelect | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.7 | INTEGER | RW | |
column · INTEGER · read-write · current This object identifies the Rate Select setting for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).
| ||||
| Ccm4gptConfigPort1Name | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.8 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for port 1. | ||||
| Ccm4gptConfigPort1Enable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.9 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether port 1 is enabled. | ||||
| Ccm4gptConfigPort2Name | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.10 | DisplayString (SIZE (0..8)) | RW | |
column · DisplayString (SIZE (0..8)) · read-write · current This object identifies a user definable name for port 2. | ||||
| Ccm4gptConfigPort2Enable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.11 | YesNoValue | RW | |
column · YesNoValue · read-write · current This object identifies whether port 2 is enabled. | ||||
| Tcm4gptLedTable | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3 | NA | ||
table · not-accessible · current Table of CM-4GPT type media converter module's LED status information. | ||||
| Rcm4gptLedEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate CM-4GPT type media converter module. | ||||
| Ccm4gptLedsSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number the CM-4GPT type module is currently inserted | ||||
| Ccm4gptLedPWR | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1.3 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the power (PWR) LED on the media converter module.
Possible status values are:
off(0) - No power to the module
onGreen(1) - Power being applied to module
blinking(2) - Loopback or Link-Test enabled
| ||||
| Ccm4gptLedLK1 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the port 1 link (LK1) LED on the
media converter module.
Possible status values are:
off(0) - No link
on(1) - Port link present
| ||||
| Ccm4gptLedLK2 | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the status of the port 2 link (LK2) LED on the
media converter module.
Possible status values are:
off(0) - No link
on(1) - Port link present
| ||||
| TmcrSfpDmiModuleTable | 1.3.6.1.4.1.1966.21.1.1.1.1.5 | NA | ||
table · not-accessible · current Table of SFP Diagnostic Monitoring Interface information for Optical Transceivers | ||||
| RmcrSfpDmiModuleEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate SFP module. | ||||
| CsfpDmiSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current The Slot number of the media converter module containing this SFP/XFP | ||||
| CsfpDmiMediaPortIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.3 | Unsigned32 | NA | |
column · Unsigned32 · not-accessible · current Media converter module port index. | ||||
| CsfpDmiStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.4 | Bits | RO | |
column · Bits · read-only · current This object identifies the status of the SFP module. If sfpCommFailed bit is set then the rest of the data in this entry is invalid
| ||||
| CsfpDmiConnectorType | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the SFP DMI connector type.
| ||||
| CsfpDmiNominalBitRate | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.6 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the SFP DMI nominal bit rate of fiber interface, in megabits per second. | ||||
| CsfpDmiLinkReach9125 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.7 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the SFP DMI maximum length in meters of media supported by the fiber transceiver for 9 micron (125 micron jacket) single-mode fiber. | ||||
| CsfpDmiLinkReach50125 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.8 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the SFP DMI maximum length in meters of media supported by the fiber transceiver for 50 micron (125 micron jacket) multi-mode fiber. | ||||
| CsfpDmiLinkReach625125 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.9 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the SFP DMI maximum length in meters of media supported by the fiber transceiver for 62.5 micron (125 micron jacket) multi-mode fiber. | ||||
| CsfpDmiFiberWaveLength | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.10 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the wavelength of the fiber interface's optical transceiver, in nanometers. | ||||
| CsfpDmiCurrentTempState | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the current alarm status for SFP DMI internally measured temperature.
| ||||
| CsfpDmiRealTimeTemp | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.12 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI real time temperature. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings. | ||||
| CsfpDmiHighTempWarn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.13 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high temperature warning threshold. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings. | ||||
| CsfpDmiHighTempAlarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.14 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high temperature warning threshold. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings. | ||||
| CsfpDmiLowTempWarn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.15 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high temperature warning threshold. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings. | ||||
| CsfpDmiLowTempAlarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.16 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high temperature warning threshold. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings. | ||||
| CsfpDmiCurrentVoltState | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.17 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies current alarm status for SFP DMI internally measured voltage.
| ||||
| CsfpDmiRealTimeVolt | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.18 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI real time voltage in Volts. | ||||
| CsfpDmiHighVoltWarn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.19 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high voltage warning threshold in Volts | ||||
| CsfpDmiHighVoltAlarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.20 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high voltage warning threshold in Volts | ||||
| CsfpDmiLowVoltWarn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.21 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high voltage warning threshold in Volts | ||||
| CsfpDmiLowVoltAlarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.22 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high voltage warning threshold in Volts | ||||
| CsfpDmiCurrentTxBiasState | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.23 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies current alarm status for SFP DMI internally measured transmit bias current in milliamps.
| ||||
| CsfpDmiRealTimeTxBias | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.24 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high TX Bias current in milliamps. | ||||
| CsfpDmiHighTxBiasWarn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.25 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high TX Bias current warning threshold in milliamps. | ||||
| CsfpDmiHighTxBiasAlarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.26 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high TX Bias current alarm threshold in milliamps. | ||||
| CsfpDmiLowTxBiasWarn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.27 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI low TX Bias current warning threshold in milliamps. | ||||
| CsfpDmiLowTxBiasAlarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.28 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI low TX Bias current alarm threshold in milliamps. | ||||
| CsfpDmiCurrentTxPowerState | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.29 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies current alarm status for SFP DMI internally measured transmit power.
| ||||
| CsfpDmiRealTimeTxPower | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.30 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI real time TX output power. The value displayed will be either millwatts or Dbm based on your current regional display settings. | ||||
| CsfpDmiHighTxPowerWarn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.31 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high TX output power warning threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | ||||
| CsfpDmiHighTxPowerAlarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.32 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high TX output power alarm threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | ||||
| CsfpDmiLowTxPowerWarn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.33 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI low TX output power warning threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | ||||
| CsfpDmiLowTxPowerAlarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.34 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI low TX output power alarm threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | ||||
| CsfpDmiCurrentRxPowerState | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.35 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies current alarm status for SFP DMI internally measured receive power.
| ||||
| CsfpDmiRealTimeRxPower | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.36 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI real time RX received optical power. The value displayed will be either millwatts or Dbm based on your current regional display settings. | ||||
| CsfpDmiHighRxPowerWarn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.37 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high RX received optical warning threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | ||||
| CsfpDmiHighRxPowerAlarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.38 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI high RX received optical alarm threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | ||||
| CsfpDmiLowRxPowerWarn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.39 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI low RX received optical warning threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | ||||
| CsfpDmiLowRxPowerAlarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.40 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI low RX received optical alarm threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | ||||
| CsfpDmiStatus2 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.41 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the status of the SFP module. If sfpCommFailed value is set then the rest of the data in this entry is invalid 0x80 - sfpModuleInserted 0x40 - sfpCommFailed 0x20 - sfpDmiSupported | ||||
| CsfpDmiVendorSerialNumber | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.42 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI serial number. | ||||
| CsfpDmiVendorName | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.43 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI serial number. | ||||
| CsfpDmiVendorPartNumber | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.44 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI serial number. | ||||
| CxfpDmiAux1Type | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.45 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the type of value that is being measured by the Auxillary 1 registers on the XFP
| ||||
| CxfpDmiAux1State | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.46 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies current alarm status for the XFP Aux1 registers
| ||||
| CxfpDmiRealTimeAux1 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.47 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI real time values for the Aux1 registers | ||||
| CxfpDmiHighAux1Warn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.48 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI high warning threshold for Aux1 | ||||
| CxfpDmiHighAux1Alarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.49 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI alarm alarm threshold for Aux1 | ||||
| CxfpDmiLowAux1Warn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.50 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI low warning threshold for Aux1 | ||||
| CxfpDmiLowAux1Alarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.51 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI low alarm threshold for Aux1 | ||||
| CxfpDmiAux2Type | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.52 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies the type of value that is being measured by the Auxillary 1 registers on the XFP
| ||||
| CxfpDmiAux2State | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.53 | INTEGER | RO | |
column · INTEGER · read-only · current This object identifies current alarm status for the XFP Aux2 registers
| ||||
| CxfpDmiRealTimeAux2 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.54 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the SFP DMI real time values for the Aux2 registers | ||||
| CxfpDmiHighAux2Warn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.55 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI high warning threshold for Aux2 | ||||
| CxfpDmiHighAux2Alarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.56 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI alarm alarm threshold for Aux2 | ||||
| CxfpDmiLowAux2Warn | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.57 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI low warning threshold for Aux2 | ||||
| CxfpDmiLowAux2Alarm | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.58 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI low alarm threshold for Aux2 | ||||
| CxfpDmiMinBitRate | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.59 | Integer32 | RO | |
column · Integer32 · read-only · current This object specifies the XFP minimum bit rate. | ||||
| CxfpDmiMaxBitRate | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.60 | Integer32 | RO | |
column · Integer32 · read-only · current This object specifies the XFP maximum bit rate. | ||||
| CxfpDmiReachEBW50125 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.61 | Integer32 | RO | |
column · Integer32 · read-only · current This object specifies the link length that is supported by the fiber transceiver using extended bandwidth 50 micron core (125 micron jacket) multimode fiber | ||||
| CsfpDmiReachCopper | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.62 | Integer32 | RO | |
column · Integer32 · read-only · current This object identifies the maximum length in meters that is supported by the SFP/XFP interface using copper cable. | ||||
| TmcrAlarmsWarningsTable | 1.3.6.1.4.1.1966.21.1.1.1.1.6 | NA | ||
table · not-accessible · current Table of outstanding alarms and warnings. | ||||
| RmcrAlarmsWarningsEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate alarm or warning. | ||||
| CalarmWarnSequenceIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.2 | Unsigned32 | NA | |
column · Unsigned32 · not-accessible · current This object identifies the sequence in which the alarms or warnings were generated. Gaps in the sequence numbers are normal. | ||||
| CalarmWarnType | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.3 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the alert/Trap number associated with this alarm/warning. | ||||
| CalarmWarnSeverity | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.4 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the severity level of the alarm/warning. Value will be one of the top three levels. | ||||
| CalarmWarnFlags | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.5 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the flags defining the alarm/warning. 0x00000002 - chassis type alert 0x00000004 - Power Supply Monitoring Unit type alert 0x00000008 - PSMU power supply type alert 0x00000010 - PSMU fan type alert 0x00000020 - Management module type alert 0x00000040 - Media converter module type alert 0x00000080 - Media converter module SFP module type alert. | ||||
| CalarmWarnChassisNum | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.6 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the chassis number associated with this alarm/warning. | ||||
| CalarmWarnDeviceNum | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.7 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the Hardware slot/bay location of the hardware associated with this alarm or warning. - 0 indicates alarm/warning occurred on the chassis backplane. - If AlarmWarnFlags indicates a power supply then this value the power supply bay number. - Otherwise it is the chassis slot number. | ||||
| CalarmWarnTimeStamp | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.8 | TimeTicks | RO | |
column · TimeTicks · read-only · current This object identifies the time stamp of when the alarm/warning was reported. (in seconds since the Epoch, defined as 0:00:00 UTC on the morning of January 1, 1970), that the alert was reported on the MCR-MGT.) | ||||
| CalarmWarnMessage | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.9 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the alarm/warning message string which will contain any values of bound variables. | ||||
| CalarmWarnPortNum | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.10 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current This object identifies the location of the media port associated with this alarm or warning. | ||||
| TmcrMediaPortTable | 1.3.6.1.4.1.1966.21.1.1.1.1.7 | NA | ||
table · not-accessible · current Table of general port status information. | ||||
| RmcrMediaPortEntry | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate media converter module port. | ||||
| CmediaPortSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.2 | Unsigned32 | NA | |
column · Unsigned32 · not-accessible · current Slot number for the media converter module containing this port. | ||||
| CmediaPortPortIndex | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.3 | Unsigned32 | NA | |
column · Unsigned32 · not-accessible · current Port number on media card. Valid values are 1 to the highest number of ports available on a media card. There are usually two ports | ||||
| CmoduleModel | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the model name of the module containing this port. | ||||
| CportName | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.5 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the name configured for this port. | ||||
| CportEnable | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current This object indicates whether the port has been enabled.
| ||||
| CportType | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current The type of port (copper, fiber, etc.) .
| ||||
| CportLinkStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current The port's current link status.
| ||||
| CportConnType | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.9 | INTEGER | RO | |
column · INTEGER · read-only · current The port's connector type
| ||||
| CportAutoNegState | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.10 | INTEGER | RO | |
column · INTEGER · read-only · current The port's auto-negotiation state
| ||||
| CportSpeed | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current If the port auto-negotiation state is complete then this object indicates the ports current auto-negotiated speed setting. If auto-negotiation is not complete then the value returned should be ignored
| ||||
| CportDuplex | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current If port auto-negotiation state is complete then this object indicates the media converter module's current auto-negotiated duplex setting for this port. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| CportPause | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.13 | INTEGER | RO | |
column · INTEGER · read-only · current If port auto-negotiation state is complete then this object indicates the media converter module's current auto-negotiated pause setting for this port. If auto-negotiation is not complete then the value returned should be ignored.
| ||||
| CportRemoteStatus | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.14 | INTEGER | RO | |
column · INTEGER · read-only · current This port's Link Partner Remote Fault status or Far End Fault status
| ||||
| CportMediaType | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.15 | INTEGER | RO | |
column · INTEGER · read-only · current The type of port (copper, fiber, etc.) .
| ||||
| CportPhysicalProtocol | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.16 | INTEGER | RO | |
column · INTEGER · read-only · current The physical networking protocol used by the port.
| ||||
| NmcrManagementGroup | 1.3.6.1.4.1.1966.21.1.1.1.2 | |||
| NmgtNetworkGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.1 | |||
| NsystemGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1 | |||
| SsystemStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SsystemName | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.2 | DisplayString (SIZE (1..63)) | RW | |
scalar · DisplayString (SIZE (1..63)) · read-write · current The name of the system management module. | ||||
| SsystemDomainName | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.3 | DisplayString (SIZE (0..32)) | RW | |
scalar · DisplayString (SIZE (0..32)) · read-write · current The domain name of the management module. | ||||
| SsystemIpAddress | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.4 | IpAddress | RW | |
scalar · IpAddress · read-write · current The management module's unique IPv4 network IP address. If you are using the management module in an IPv6 network, this field can be left blank. | ||||
| SsystemSubnetBits | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.5 | Integer32 (0..32) | RW | |
scalar · Integer32 (0..32) · read-write · current The number of bits in the subnet mask. For example, a subnet mask of 255.255.0.0 has 16 subnet/prefix bits. Valid values are 0-32. The default is 0. When the value is 0, the correct value is determined based on the class of the IP Address. | ||||
| SsystemDHCPUpdateDNS | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.6 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current If enabled, the DNS system will be updated after the management module gets the IP address via DHCP. | ||||
| SsystemAutoObtainDNS | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.7 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current If on, the DNS server IP address will be obtained automatically automatically via DHCP. | ||||
| SsystemAutoObtainGW | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.8 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current If enabled, the default gateway IP address will be get automatically via DHCP. | ||||
| SsystemDomainPrefix | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.9 | DisplayString (SIZE (0..7)) | RW | |
scalar · DisplayString (SIZE (0..7)) · read-write · current The domain prefix for primary Ethernet interface of the management module. | ||||
| SsystemTFTPRetry | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.10 | Integer32 (0..5) | RW | |
scalar · Integer32 (0..5) · read-write · current The number of times the management module will attempt to transfer (using TFTP) a file to/from a host. Default is 5. A value of 0 (zero) means that the management module will not attempt a retry should TFTP fail. | ||||
| SsystemTFTPTimeOut | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.11 | Integer32 (3..10) | RW | |
scalar · Integer32 (3..10) · read-write · current The time, in seconds, that the management module will wait for a successful transmit or receipt of TFTP packets before retrying a TFTP transfer. Default is 3 seconds. | ||||
| TgatewayTable | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2 | NA | ||
table · not-accessible · current Table of configured gateway. | ||||
| RgatewayEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate configured gateway.
| ||||
| CgatewayIndex | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.1 | GenericTableIndex | NA | |
column · GenericTableIndex · not-accessible · current gatewayIndex | ||||
| CgatewayStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.2 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| CgatewayHost | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.3 | DisplayString (SIZE (0..14)) | RW | |
column · DisplayString (SIZE (0..14)) · read-write · current You can specify up to twenty hosts to act as gateways in your network. Each gateway host must be defined in the management module host table. | ||||
| CgatewayType | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.4 | INTEGER | RW | |
column · INTEGER · read-write · current Specify the type of gateway:
Default-A gateway which provides general access beyond
your local network.
Host-A gateway reserved for accessing a specific host
external to your local network.
Network-A gateway reserved for accessing a specific
network external to your local network.
| ||||
| CgatewayIpAddress | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.5 | Ipv4v6Address | RW | |
column · Ipv4v6Address · read-write · current When the gateway is a Host or Network gateway, you must specify the IP address of the target host machine/network. | ||||
| CgatewaySubnetBits | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.6 | Integer32 (0..128) | RW | |
column · Integer32 (0..128) · read-write · current When the gateway is a Network gateway, you must specify the subnet/prefix bits for that network. If the IP address is IPv4, then the Subnet/Prefix Bits range is 0-32. If the IP address is IPv6, then the Subnet/Prefix Bits range is 0-128. | ||||
| CgatewayInterface | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.7 | DisplayString (SIZE (0..20)) | RW | |
column · DisplayString (SIZE (0..20)) · read-write · current The interface that the management module is going to use to access the Remote Host. | ||||
| ThostTable | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3 | NA | ||
table · not-accessible · current The hosts Group table. | ||||
| RhostEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1 | NA | ||
row · not-accessible · current An entry in the host table, each relating to a separate host.
| ||||
| ChostIndex | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.1 | GenericTableIndex | NA | |
column · GenericTableIndex · not-accessible · current The table entry number for this host. | ||||
| ChostStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.2 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| ChostName | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.3 | DisplayString (SIZE (0..14)) | RW | |
column · DisplayString (SIZE (0..14)) · read-write · current The host name used for this host entry. To delete an entry, blank out this field. If blank, this entry is currently unused. | ||||
| ChostIpAddr | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.4 | Ipv4v6Address | RW | |
column · Ipv4v6Address · read-write · current The host IP address used for this entry. | ||||
| ChostFqdn | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.5 | DisplayString (SIZE (0..255)) | RW | |
column · DisplayString (SIZE (0..255)) · read-write · current The host full qualified domain name for the host entry. If blank, this entry is currently unused. | ||||
| TdnsTable | 1.3.6.1.4.1.1966.21.1.1.1.2.1.4 | NA | ||
table · not-accessible · current Table of DNS hosts | ||||
| RdnsEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate DNS host.
| ||||
| CdnsIndex | 1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1.1 | GenericTableIndex | NA | |
column · GenericTableIndex · not-accessible · current DNS host index | ||||
| CdnsStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1.2 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| CdnsIpAddress | 1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1.3 | Ipv4v6Address | RW | |
column · Ipv4v6Address · read-write · current You can specify the IP addresses for up to two DNS (Domain Name Servers) hosts in your network. The first DNS entry in the list is the primary DNS and the second DNS entry is the secondary server. | ||||
| CdnsActive | 1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1.4 | OnOffValue | RW | |
column · OnOffValue · read-write · current Activates/deactivates a DNS entry. | ||||
| NdynamicDNSGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5 | |||
| SdynamicDNSStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of
the following values will be returned:
1-Indicates that the container folder is active with no changes.
2-Indicates that the container folder is active with change(s).
Once you have completed setting the variables in a folder, you
will want to submit your changes to the management module. To do
this, set the Status variable to 4. If you want to discard the
changes, set the Status variable to 6.
4-Indicates that the changes in the container folder are to be
submitted to the management module and verified. To save the
changes to flash a write of writeToFlash(1) in the adminFunction
object is required.
6-Indicates that the changes in the container folder are to be
discarded. | ||||
| SdynamicDNS | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.2 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Enable/disable dynamic DNS. | ||||
| SdynamicDNSHostname | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.3 | DisplayString (SIZE (1..14)) | RW | |
scalar · DisplayString (SIZE (1..14)) · read-write · current Host name. | ||||
| SdynamicDNSUserName | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.4 | DisplayString (SIZE (1..16)) | RW | |
scalar · DisplayString (SIZE (1..16)) · read-write · current User name. | ||||
| SdynamicDNSPassword | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.5 | DisplayString (SIZE (1..16)) | RW | |
scalar · DisplayString (SIZE (1..16)) · read-write · current This object identifies the dynamic DNS password. Reading of this object will always return a blank string | ||||
| SdynamicDNSSystemType | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.6 | INTEGER | RW | |
scalar · INTEGER · read-write · current System type.
| ||||
| SdynamicDNSWildCard | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.7 | INTEGER | RW | |
scalar · INTEGER · read-write · current Specifies whether to add a alias such as * to your registered host name.
| ||||
| SdynamicDNSConnectionMethod | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.8 | INTEGER | RW | |
scalar · INTEGER · read-write · current Specifies how the management module is going to connection to the DynDNS.org server.
| ||||
| SdynamicDNSSSLVerifyPeerCertificate | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.9 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Enable this option when you want the Validation Criteria to match the Peer Certificate for authentication to pass. If you enable this option, you need to download an SSL/TLS certificate authority (CA) list file to the management module. Any values that are entered in the validation criteria must match the peer certificate for an SSL connection; any fields left blank will not be validated against the peer certificate. | ||||
| SdynamicDNSSSLCountry | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.10 | DisplayString (SIZE (0..2)) | RW | |
scalar · DisplayString (SIZE (0..2)) · read-write · current A two character country code; for example, US. | ||||
| SdynamicDNSSSLStateProv | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.11 | DisplayString (SIZE (0..128)) | RW | |
scalar · DisplayString (SIZE (0..128)) · read-write · current Up to a 128 character entry for the state/province; for example, IL. | ||||
| SdynamicDNSSSLLocality | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.12 | DisplayString (SIZE (0..128)) | RW | |
scalar · DisplayString (SIZE (0..128)) · read-write · current Up to a 128 character entry for the location; for example, a city. | ||||
| SdynamicDNSSSLOrganisation | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.13 | DisplayString (SIZE (0..64)) | RW | |
scalar · DisplayString (SIZE (0..64)) · read-write · current Up to a 64 character entry for the organization; for example, Accounting. | ||||
| SdynamicDNSSSLOrganisationUnit | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.14 | DisplayString (SIZE (0..64)) | RW | |
scalar · DisplayString (SIZE (0..64)) · read-write · current Up to a 64 character entry for the unit in the organization; for example, Payroll. | ||||
| SdynamicDNSSSLCommonName | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.15 | DisplayString (SIZE (0..64)) | RW | |
scalar · DisplayString (SIZE (0..64)) · read-write · current Up to a 64 character entry for common name; for example, the host name or fully qualified domain name. | ||||
| SdynamicDNSSSLEmail | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.16 | DisplayString (SIZE (0..128)) | RW | |
scalar · DisplayString (SIZE (0..128)) · read-write · current Up to a 64 character entry for an email address; for example, [email protected]. | ||||
| SdynamicDNSStatusString | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.17 | OCTET STRING (SIZE (0..1024)) | RO | |
scalar · OCTET STRING (SIZE (0..1024)) · read-only · current Dynamic DNS statistics | ||||
| TdynamicDNSSSLCipherTable | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18 | NA | ||
table · not-accessible · current SSL Cipher. | ||||
| RdynamicDNSSSLCipherEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1 | NA | ||
row · not-accessible · current An entry in the dynamicDNSSSLCipherTable, each relating to a cipher entry. | ||||
| CdynamicDNSSSLCipherPriority | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.1 | Integer32 (1..5) | NA | |
column · Integer32 (1..5) · not-accessible · current The cipher priority. 1- highest 5 - lowest. | ||||
| CdynamicDNSSSLCipherStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.2 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of
the following values will be returned:
1-Indicates that the container folder is active with no changes.
2-Indicates that the container folder is active with change(s).
Once you have completed setting the variables in a folder, you
will want to submit your changes to the management module. To do
this, set the Status variable to 4. If you want to discard the
changes, set the Status variable to 6.
4-Indicates that the changes in the container folder are to be
submitted to the management module and verified. To save the
changes to flash a write of writeToFlash(1) in the adminFunction
object is required.
6-Indicates that the changes in the container folder are to be
discarded. | ||||
| CdynamicDNSSSLCipherEncryption | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.3 | INTEGER | RW | |
column · INTEGER · read-write · current SSL Encryption. None is not allowed for priority 1. Any will use the first encryption format that can be negotiated. The default is any.
| ||||
| CdynamicDNSSSLCipherKeySizeMin | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.4 | INTEGER | RW | |
column · INTEGER · read-write · current The minimum key size value that will be used for the specified encryption type. The default is 40.
| ||||
| CdynamicDNSSSLCipherKeySizeMax | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current The maximum key size value that will be used for the specified encryption type. The default is 256.
| ||||
| CdynamicDNSSSLCipherKeyExchange | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.6 | INTEGER | RW | |
column · INTEGER · read-write · current The type of key to exchange for the encryption format:
Any-Any key exchange that is valid is used (this does
not, however, include ADH keys).
RSA-This is an RSA key exchange using an RSA key and
certificate.
EDHRSA-This is an EDH key exchange using an RSA key
and certificate.
EDHDSS-This is an EDH key exchange using a DSA key
and certificate.
ADH-This is an anonymous key exchange which does not
require a private key or certificate. Choose this
key if you do not want to authenticate the peer device,
but you want the data encrypted on the SSL/TLS connection.
The default is Any.
| ||||
| CdynamicDNSSSLCipherHMAC | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.7 | INTEGER | RW | |
column · INTEGER · read-write · current Select the key-hashing for message authentication method for your encryption type: Any, MD5, or SHA1. The default is Any.
| ||||
| Nipv6Group | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6 | |||
| Nipv6ServicesGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1 | |||
| Sipv6serviceStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of
the following values will be returned:
1-Indicates that the container folder is active with no changes.
2-Indicates that the container folder is active with change(s).
Once you have completed setting the variables in a folder, you
will want to submit your changes to the management module. To do
this, set the Status variable to 4. If you want to discard the
changes, set the Status variable to 6.
4-Indicates that the changes in the container folder are to be
submitted to the management module and verified. To save the
changes to flash a write of writeToFlash(1) in the adminFunction
object is required.
6-Indicates that the changes in the container folder are to be
discarded. | ||||
| SserviceAutoDiscovery | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.2 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current When on, the management module will send out a Router Solicitation message. If a Router Advertisement message is received, the management module will configure the IPv6 address(es) and configuration parameters based on the information contained in the advertisement. If no Router Advertisement message is received, the management module will attempt to connect to a DHCPv6 server to obtain IPv6 addresses and other configuration parameters. Default on. | ||||
| SserviceDHCPv6 | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.3 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current When on, requests IPv6 address(es) and configuration information from the DHCPv6 server. Default off. | ||||
| SserviceDHCPv6IPAddresses | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.4 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current When on, the management module will accept IPv6 address(es) from the DHCPv6 server. | ||||
| SserviceDHCPv6NetworkPrefix | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.5 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current When on, the management module will accept the network prefix from the DHCPv6 server. | ||||
| SserviceDHCPv6AutoObtainDNS | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.6 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current If on, the DNS server IP address will be obtained automatically automatically via DHCP. | ||||
| Tipv6AddressTable | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2 | NA | ||
table · not-accessible · current IPv6 custom address table. | ||||
| Ripv6AddressEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1 | NA | ||
| Cipv6AddressIndex | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.1 | GenericTableIndex | NA | |
column · GenericTableIndex · not-accessible · current Custom IPv6 address index. | ||||
| Cipv6AddressStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.2 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of
the following values will be returned:
1-Indicates that the container folder is active with no changes.
2-Indicates that the container folder is active with change(s).
Once you have completed setting the variables in a folder, you
will want to submit your changes to the management module. To do
this, set the Status variable to 4. If you want to discard the
changes, set the Status variable to 6.
4-Indicates that the changes in the container folder are to be
submitted to the management module and verified. To save the
changes to flash a write of writeToFlash(1) in the adminFunction
object is required.
6-Indicates that the changes in the container folder are to be
discarded. | ||||
| Cipv6AddressAddr | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.3 | Ipv4v6Address | RW | |
column · Ipv4v6Address · read-write · current Either enter a network prefix that the Device Server will use to derive an IPv6 address using the Device Server's MAC address (must turn ipv6AddressAuto1 on) or enter a specific IPv6 address. | ||||
| Cipv6AddressPrefixBits | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.4 | Integer32 (0..128) | RW | |
column · Integer32 (0..128) · read-write · current The IPv6 prefix bits of either the network or IPv6 address. | ||||
| Cipv6AddressAuto | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.5 | OnOffValue | RW | |
column · OnOffValue · read-write · current When on, the management module will derive an IPv6 address from the entered network prefix and the management module's MAC address. | ||||
| Cipv6AddressSendAdvertise | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.6 | OnOffValue | RW | |
column · OnOffValue · read-write · current When on, the management module will include the IPv6 address in router advertisements. | ||||
| Tinterfacev6StatsTable | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3 | NA | ||
table · not-accessible · current The interface IPv6 Group table. | ||||
| Rinterfacev6StatsEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1 | NA | ||
| Cinterfacev6Index | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.1 | GenericTableIndex | NA | |
column · GenericTableIndex · not-accessible · current The IPv6 interface index. | ||||
| Cinterfacev6Name | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.2 | DisplayString | RO | |
column · DisplayString · read-only · current The IPv6 interface name. | ||||
| Cinterfacev6Address | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current The IPv6 interface IP address. | ||||
| Cinterfacev6PrefixBits | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.4 | Integer32 (0..128) | RO | |
column · Integer32 (0..128) · read-only · current The IPv6 interface Prefix bits | ||||
| Cinterfacev6Scope | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current The IPv6 interface scope.
| ||||
| Tipv6TunnelTable | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4 | NA | ||
table · not-accessible · current IPv6 tunnel table. | ||||
| Ripv6TunnelEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1 | NA | ||
| Cipv6TunnelIndex | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.1 | GenericTableIndex | NA | |
column · GenericTableIndex · not-accessible · current The IPv6 tunnel index. | ||||
| Cipv6TunnelStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.2 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| Cipv6TunnelName | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.3 | DisplayString | RW | |
column · DisplayString · read-write · current The name of the IPv6 tunnel. Maximum 16 alphanumeric characters. | ||||
| Cipv6TunnelMode | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.4 | INTEGER | RW | |
column · INTEGER · read-write · current The method or protocol that is used to create the IPv6 tunnel.
o Manual-When specified, the management module will manually create the IPv6
tunnel to the specified Remote Host through the specified Interface.
o ip6to4-When specified, the MCR-MGT will broadcast to the multicast
address 192.88.99.1 through the specified Interface. When the
closest ip6to4 router responds, it will create the IPv6 tunnel,
encapsulating and decapsulating IPv6 traffic sent to and from
the management module.
o Teredo-When specified, the Teredo protocol encapsulates the IPv6
packet as an IPv4 UDP message, allowing it to pass through most
network address translator (NAT) boxes and create an IPv6 tunnel
to the specified Remote Host (a Teredo server) through the
specified Interface.
Default is Manual.
| ||||
| Cipv6TunnelRemoteHost | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.5 | DisplayString | RW | |
column · DisplayString · read-write · current The IPv4 host that can access the IPv6 network when the Mode is Manual. The Teredo server when the Mode is Teredo. | ||||
| NmgtAccessGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.2 | |||
| NmgtAcessServicesGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1 | |||
| SaccessServicesStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SaccessServicesSessInactTimeout | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.2 | Integer32 (0..4294967) | RW | |
scalar · Integer32 (0..4294967) · read-write · current The amount of time, in seconds, that the management session inactivity timer will run. When the timer expires, becuase no activity on the management session within the specified time, the management module will reset the management session. A value of 0 (zero), means that the inactivity timer will not expire (the session is open permanently, or until the user logs out). | ||||
| SaccessServiceHTTPD | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.3 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Turn on/off the HTTPD Service | ||||
| SaccessServiceHTTPSD | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.4 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Turn on/off the HTTPSD Service | ||||
| SaccessServiceTelnetD | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.5 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Turn on/off the TelnetD Service | ||||
| SacessServiceSSHD | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.6 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Turn on/off the SSHD Service | ||||
| SacessServiceSnmpD | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.7 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Turn on/off the SnmpD Service | ||||
| SacessServiceSetIP | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.8 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Turn on/off the SetIP Service | ||||
| SacessIncomingPings | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.9 | EnableDisableValue | RW | |
scalar · EnableDisableValue · read-write · current Allow incoming ping requests. | ||||
| NwebManagerGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.2.2 | |||
| SwebManagerStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.2.2.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| ShttpsPassphrase | 1.3.6.1.4.1.1966.21.1.1.1.2.2.2.2 | DisplayString (SIZE (1..16)) | RW | |
scalar · DisplayString (SIZE (1..16)) · read-write · current This object identifies the HTTPS SSL certificate passphrase. Reading of this object will always return a blank string | ||||
| NsshServerGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3 | |||
| SsshServerStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SsshServerAuthRSA | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.2 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current When a client SSH session requests RSA authentication, the management module's SSH server will authenticate the user via RSA. | ||||
| SsshServerAuthDSA | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.3 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current When a client SSH session requests DSA authentication, the management module's SSH server will authenticate the user via DSA | ||||
| SsshServerAuthKeyboard | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.4 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current The user types in a password for authentication. | ||||
| SsshServerAuthPassword | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.5 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current The user types in a password for authentication. | ||||
| SsshServerCipher3Des | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.6 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current The management module SSH server's 3DES encryption is enable/disabled. | ||||
| SsshServerCipherBlowfish | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.7 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current The management module SSH server's Blowfish encryption is enabled/disabled. | ||||
| SsshServerCipherCipherAES | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.8 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current The management module SSH server's AES encryption is enabled/disabled | ||||
| SsshServerCipherCAST | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.9 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current The management module SSH server's CAST encryption is enabled/disabled | ||||
| SsshServerCipherArcfour | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.10 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current The management module SSH server's Arcfour encryption is enabled/disabled. | ||||
| SsshServerVerbose | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.11 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Displays debug messages on the terminal. | ||||
| SsshServerCompression | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.12 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Requests compression of all data. Compression is desirable on slow connections, but will only slow down things on fast networks. | ||||
| SsshServerSSH1 | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.13 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Enable/Disable SSH-1 on the server. | ||||
| NsnmpAgentGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4 | |||
| SsnmpAgentStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SsnmpContact | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.2 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current The name and contract information of the person who manages this SMNP node. | ||||
| SsnmpLocation | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.3 | DisplayString (SIZE (0..32)) | RW | |
scalar · DisplayString (SIZE (0..32)) · read-write · current The physical location of the SNMP node. | ||||
| TsnmpCommunityTable | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4 | NA | ||
table · not-accessible · current Table of SNMP communities configured for the MCR-MGT agent | ||||
| RsnmpCommunityEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate SNMP community definition
| ||||
| CsnmpCommunityIndex | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.1 | GenericTableIndex | NA | |
column · GenericTableIndex · not-accessible · current The MCR-MGT agent community index | ||||
| CsnmpCommunityStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.2 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| CsnmpCommunityName | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.3 | DisplayString (SIZE (0..14)) | RW | |
column · DisplayString (SIZE (0..14)) · read-write · current A name that will be sent to the management module from an SNMP manager. This name will define the permissions of the manager. | ||||
| CsnmpCommunityIpAddress | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.4 | Ipv4v6Address | RW | |
column · Ipv4v6Address · read-write · current The IP address of the SNMP manager that will send requests to the management module. If the address is 0.0.0.0, any SNMP manager with the Community Name can access the management module. | ||||
| CsnmpCommunityPermission | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current Permits the management module to respond to SNMP requests by: None -There is no response to requests from SNMP. Readonly -Responds only to Read requests from SNMP. Readwrite -Responds to both Read and Write requests from SNMP.
| ||||
| NsnmpV3ReadOnlyUser | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5 | |||
| SsnmpV3ReadOnlyStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SsnmpV3ReadOnlyUserName | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.2 | DisplayString (SIZE (0..16)) | RW | |
scalar · DisplayString (SIZE (0..16)) · read-write · current SNMP v3 read-only user name. This SNMP v3 user will have read-only S SNMP access permissions. | ||||
| SsnmpV3ReadOnlySecurityLevel | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.3 | INTEGER | RW | |
scalar · INTEGER · read-write · current Specifies the SNMP v3 read-only user security level.
| ||||
| SsnmpV3ReadOnlyAuthAlgorithm | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.4 | INTEGER | RW | |
scalar · INTEGER · read-write · current Specifies the SNMP v3 read-only user authentication method.
| ||||
| SsnmpV3ReadOnlyAuthPasswd | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.5 | DisplayString (SIZE (0..128)) | RW | |
scalar · DisplayString (SIZE (0..128)) · read-write · current Specifies the SNMP v3 read-only user authentication password. | ||||
| SsnmpV3ReadOnlyPrivacyAlgorithm | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.6 | INTEGER | RW | |
scalar · INTEGER · read-write · current Specifies the SNMP v3 read-only user privacy algorithm.
| ||||
| SsnmpV3ReadOnlyPrivacyPasswd | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.7 | DisplayString (SIZE (0..128)) | RW | |
scalar · DisplayString (SIZE (0..128)) · read-write · current Specifies the SNMP v3 read-only user privacy password. | ||||
| NsnmpV3ReadWriteUser | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6 | |||
| SsnmpV3ReadWriteStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SsnmpV3ReadWriteUserName | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.2 | DisplayString (SIZE (0..16)) | RW | |
scalar · DisplayString (SIZE (0..16)) · read-write · current Specifies the SNMP v3 read-write user name. This SNMP v3 user will have read-write SNMP access permissions. | ||||
| SsnmpV3ReadWriteSecurityLevel | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.3 | INTEGER | RW | |
scalar · INTEGER · read-write · current Specifies the SNMP v3 read-write user security level.
| ||||
| SsnmpV3ReadWriteAuthAlgorithm | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.4 | INTEGER | RW | |
scalar · INTEGER · read-write · current Specifies the SNMP v3 read-write user authentication method.
| ||||
| SsnmpV3ReadWriteAuthPasswd | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.5 | DisplayString (SIZE (0..128)) | RW | |
scalar · DisplayString (SIZE (0..128)) · read-write · current Specifies the SNMP v3 read-write user authentication password. | ||||
| SsnmpV3ReadWritePrivacyAlgorithm | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.6 | INTEGER | RW | |
scalar · INTEGER · read-write · current Specifies the SNMP v3 read-write user privacy algorithm.
| ||||
| SsnmpV3ReadWritePrivacyPasswd | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.7 | DisplayString (SIZE (0..128)) | RW | |
scalar · DisplayString (SIZE (0..128)) · read-write · current Specifies the SNMP v3 read-write user privacy password. | ||||
| NauthorizedHostGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5 | |||
| SauthHostsStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SauthHostOnly | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.2 | YesNoValue | RW | |
scalar · YesNoValue · read-write · current Determines whether only authorized hosts are allowed to access the management module. If set to yes then the management module will only respond to, and allow access to and from, the IP or MAC addresses of hosts configured in the authorized IP and MAC hosts tables. | ||||
| TauthIpHostTable | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3 | NA | ||
table · not-accessible · current The hosts Group table. | ||||
| RauthIpHostEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1 | NA | ||
row · not-accessible · current An entry in the AuthIpHostTable, each relating to a IP host.
| ||||
| CauthHostIpIndex | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1.1 | GenericTableIndex | NA | |
column · GenericTableIndex · not-accessible · current The table entry number for this host. | ||||
| CauthHostIpStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1.2 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| CauthHostIpAddr | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1.3 | Ipv4v6Address | RW | |
column · Ipv4v6Address · read-write · current The host IP address used for this entry. | ||||
| CauthHostIpDescr | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1.4 | DisplayString (SIZE (0..21)) | RW | |
column · DisplayString (SIZE (0..21)) · read-write · current The host IP entry description. | ||||
| TauthMacHostTable | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4 | NA | ||
table · not-accessible · current The hosts Group table. | ||||
| RauthMacHostEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1 | NA | ||
row · not-accessible · current An entry in the AuthIpHostTable, each relating to a host.
| ||||
| CauthHostMacIndex | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1.1 | GenericTableIndex | NA | |
column · GenericTableIndex · not-accessible · current The table entry number for this host. | ||||
| CauthHostMacStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1.2 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| CauthHostMacAddr | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1.3 | MacAddress | RW | |
column · MacAddress · read-write · current The host MAC address used for this entry. | ||||
| CauthHostMacDescr | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1.4 | DisplayString (SIZE (0..21)) | RW | |
column · DisplayString (SIZE (0..21)) · read-write · current The host MAC address entry description. | ||||
| NmgtAlertGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.3 | |||
| NalertLocalEventGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.3.1 | |||
| SlocalEventLogStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.3.1.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SlocalEventLogEnabled | 1.3.6.1.4.1.1966.21.1.1.1.2.3.1.2 | YesNoValue | RW | |
scalar · YesNoValue · read-write · current Determines whether alert events are logged to the internal local event log. | ||||
| SlocalEventLogAlertLevel | 1.3.6.1.4.1.1966.21.1.1.1.2.3.1.3 | AlertSeverityLevel | RW | |
scalar · AlertSeverityLevel · read-write · current Choose the alert level that will trigger a local event being stored in the local event log. When you select an alert level, all alerts that appear above it in the list will also trigger a local event log message. For example, if you select oneTimeError, all oneTimeError, persistantError, moduleLevelFault, and systemLevelFault alert events will be generate a local event message. | ||||
| SlocalEventLogClear | 1.3.6.1.4.1.1966.21.1.1.1.2.3.1.4 | YesNoValue | RW | |
scalar · YesNoValue · read-write · current Writing a yes(1) to this object will clear the local event log on the management module. Reading of this object will always return 0 | ||||
| NalertSyslogGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.3.2 | |||
| SsyslogStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.3.2.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SsyslogEnabled | 1.3.6.1.4.1.1966.21.1.1.1.2.3.2.2 | YesNoValue | RW | |
scalar · YesNoValue · read-write · current Determines whether syslog is enabled. | ||||
| SsyslogSeverityLevel | 1.3.6.1.4.1.1966.21.1.1.1.2.3.2.3 | INTEGER | RW | |
scalar · INTEGER · read-write · current Choose the severity level that will trigger a syslog message:
Emergency, Alert, Critical, Error, Warning, Notice, Info, Debug
When you select a severity level, all the levels that appear above it in
the list will also trigger a syslog message. For example, if you select
Error, all Error, Critical, Alert, and Emergency events will generate a
syslog message.
NOTE: In addition to alert events, syslog message will also be generated
for several non-alert system events
| ||||
| SsyslogPrimaryHost | 1.3.6.1.4.1.1966.21.1.1.1.2.3.2.4 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current The first preconfigured host that the management module will attempt to send system log messages to; messages will be displayed on the host's monitor. | ||||
| SsyslogSecondaryHost | 1.3.6.1.4.1.1966.21.1.1.1.2.3.2.5 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current If the management module cannot communicate with the primary host, then the management module will attempt to send system log messages to this preconfigured host; messages will be displayed on the host's monitor. | ||||
| NalertSnmpTrapGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3 | |||
| SsnmpTrapStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SsnmpTrapEnabled | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.2 | YesNoValue | RW | |
scalar · YesNoValue · read-write · current Determines whether SNMP Traps are enabled. | ||||
| SsnmpTrapAlertLevel | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.3 | AlertSeverityLevel | RW | |
scalar · AlertSeverityLevel · read-write · current Choose the alert level that will trigger a SNMP trap message to be sent if SNMP traps is enabled. When you select an alert level, all alerts that appear above it in the list will also trigger a local event log message. For example, if you select oneTimeError, all oneTimeError, persistantError, moduleLevelFault, and systemLevelFault alert events will be generate a SNMP trap message. | ||||
| TsnmpTrapHostTable | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4 | NA | ||
table · not-accessible · current Table of SNMP Trap Hosts information. | ||||
| RsnmpTrapHostEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate SNMP trap host.
| ||||
| CsnmpTrapHostIndex | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.1 | GenericTableIndex | AN | |
column · GenericTableIndex · accessible-for-notify · current This object identifies the SNMP trap host index. | ||||
| CsnmpTrapHostStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.2 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of
the following values will be returned:
1-Indicates that the container folder is active with no changes.
2-Indicates that the container folder is active with change(s).
Once you have completed setting the variables in a folder, you
will want to submit your changes to the management module. To do
this, set the Status variable to 4. If you want to discard the
changes, set the Status variable to 6.
4-Indicates that the changes in the container folder are to be
submitted to the management module and verified. To save the
changes to flash a write of writeToFlash(1) in the adminFunction
object is required.
6-Indicates that the changes in the container folder are to be
discarded. | ||||
| CsnmpTrapHostIpAddress | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.3 | Ipv4v6Address | RW | |
column · Ipv4v6Address · read-write · current Defines the hosts (by IP address) that will receive trap messages generated by the management module. | ||||
| CsnmpTrapHostUdpPort | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.4 | Integer32 (1..65535) | RW | |
column · Integer32 (1..65535) · read-write · current Defines the UDP port number the SNMP trap host will listen on to receive trap messages generated by the management module. | ||||
| CsnmpTrapHostVersion | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current Defines the SNMP version of the traps sent to this host. If snmpTrapV3 is selected then the SNMP trap v3 user
| ||||
| CsnmpTrapHostType | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.6 | INTEGER | RW | |
column · INTEGER · read-write · current If set to snmpInform(1) the management module will send traps via an INFORM-PDU, expecting a response from the trap host, retransmitting if required. Otherwise it will send them via a TRAP-PDU or TRAP2-PDU. This object is ignored for for SNMP v1
| ||||
| CsnmpTrapHostCommunity | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.7 | DisplayString (SIZE (0..14)) | RW | |
column · DisplayString (SIZE (0..14)) · read-write · current An arbitrary trap community name. This object is ignored for SNMP v3 | ||||
| CsnmpTrapHostEnable | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.8 | YesNoValue | RW | |
column · YesNoValue · read-write · current If set to No, the management module will not use this table entry to send traps. | ||||
| NsnmpV3TrapUser | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5 | |||
| SsnmpV3TrapUserStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SsnmpV3TrapUserUserName | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.2 | DisplayString (SIZE (0..16)) | RW | |
scalar · DisplayString (SIZE (0..16)) · read-write · current SNMP trap v3 user name. This user will be used for every SNMP trap host that is using snmpTrapHostVersion of snmpTrapV3(2) | ||||
| SsnmpV3TrapUserSecurityLevel | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.3 | INTEGER | RW | |
scalar · INTEGER · read-write · current SNMP trap v3 user security level.
| ||||
| SsnmpV3TrapUserAuthAlgorithm | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.4 | INTEGER | RW | |
scalar · INTEGER · read-write · current SNMP trap v3 user authentication method.
| ||||
| SsnmpV3TrapUserAuthPasswd | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.5 | DisplayString (SIZE (0..128)) | RW | |
scalar · DisplayString (SIZE (0..128)) · read-write · current SNMP trap v3 user authentication password. | ||||
| SsnmpV3TrapUserPrivacyAlgorithm | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.6 | INTEGER | RW | |
scalar · INTEGER · read-write · current SNMP trap v3 user privacy algorithm.
| ||||
| SsnmpV3TrapUserPrivacyPasswd | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.7 | DisplayString (SIZE (0..128)) | RW | |
scalar · DisplayString (SIZE (0..128)) · read-write · current SNMP trap v3 user privacy password. | ||||
| SsnmpTrapGlbHostTimeout | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.6 | Integer32 (0..65535) | RW | |
scalar · Integer32 (0..65535) · read-write · current Defines the timeout in miliseconds between retries of sending the SNMP INFORM-PDU if no response is received for the trap host. | ||||
| SsnmpTapGlobHostRetries | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.7 | Integer32 (0..65535) | RW | |
scalar · Integer32 (0..65535) · read-write · current Defines the number of retries to send the SNMP INFORM-PDU trap if no response is received from the trap host. | ||||
| SsnmpV3LocalEngineID | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.8 | SnmpEngineID | RO | |
scalar · SnmpEngineID · read-only · current An SNMPv3 engine ID used by the MCR-MGT for identification when sending SNMP v3 traps. | ||||
| SsnmpV3LocalEngineIDTextSuffix | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.9 | DisplayString (SIZE (0..27)) | RW | |
scalar · DisplayString (SIZE (0..27)) · read-write · current This configured text is used to build the suffix of the SNMPv3 engine ID | ||||
| NsnmpTrapVarsGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10 | |||
| SmgtAccessMethod | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.1 | INTEGER | AN | |
scalar · INTEGER · accessible-for-notify · current Defines the management protocol used to access the management module
| ||||
| SremoteMgtIpAddress | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.2 | DisplayString | AN | |
scalar · DisplayString · accessible-for-notify · current Defines the remote IP address accessing the management module | ||||
| SremoteTftpHost | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.3 | DisplayString (SIZE (0..64)) | AN | |
scalar · DisplayString (SIZE (0..64)) · accessible-for-notify · current Defines the remote TFTP server IP address or host name performing the TFP file transfer | ||||
| SremoteTftpFileName | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.4 | DisplayString (SIZE (0..64)) | AN | |
scalar · DisplayString (SIZE (0..64)) · accessible-for-notify · current Defines the remote TFTP file name | ||||
| SnetworkIpAddress | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.5 | Ipv4v6Address | AN | |
scalar · Ipv4v6Address · accessible-for-notify · current Defines the IP address assigned to the management module | ||||
| SmcrMediaPortNum | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.6 | Unsigned32 (1..2) | AN | |
scalar · Unsigned32 (1..2) · accessible-for-notify · current This object identifies the media converter module port number. | ||||
| SmcrMediaPortDescr | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.7 | DisplayString | AN | |
scalar · DisplayString · accessible-for-notify · current A description of the media port that consists of the user defined media port name, followed by the system name for the port. | ||||
| SeventSeverityLevel | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.8 | AlertSeverityLevel | AN | |
scalar · AlertSeverityLevel · accessible-for-notify · current The severity level of the event that generated this trap. | ||||
| SxfpDmiRealTimeAux | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.9 | DisplayString (SIZE (0..32)) | RO | |
scalar · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI real time values for one of the auxillary register sets. | ||||
| SxfpDmiHighAuxWarn | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.10 | DisplayString (SIZE (0..32)) | RO | |
scalar · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI high warning threshold for one of the auxillary register sets. | ||||
| SxfpDmiHighAuxAlarm | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.11 | DisplayString (SIZE (0..32)) | RO | |
scalar · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI alarm alarm threshold for one of the auxillary register sets. | ||||
| SxfpDmiLowAuxWarn | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.12 | DisplayString (SIZE (0..32)) | RO | |
scalar · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI low warning threshold for one of the auxillary register sets. | ||||
| SxfpDmiLowAuxAlarm | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.13 | DisplayString (SIZE (0..32)) | RO | |
scalar · DisplayString (SIZE (0..32)) · read-only · current This object identifies the XFP DMI low alarm threshold for one of the auxillary register sets. | ||||
| SmcrModuleSubTypeInserted | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.14 | INTEGER | RO | |
scalar · INTEGER · read-only · current This object identifies the module sub-type inserted in the slot.
| ||||
| SmcrMediaBackedupModuleSubType | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.15 | INTEGER | RO | |
scalar · INTEGER · read-only · current This object identifies the module sub-type of the backup configuration.
| ||||
| SmcrMediaPortBandwidth | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.16 | Unsigned32 | AN | |
scalar · Unsigned32 · accessible-for-notify · current This object identifies the media converter module port's current bandwith in kbps. | ||||
| SmcrMediaPortBandwidthThreshold | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.17 | Unsigned32 | AN | |
scalar · Unsigned32 · accessible-for-notify · current This object identifies the media converter module port's bandwith threshold in kbps. | ||||
| NalertEmailGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4 | |||
| SemailStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SemailEnabled | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.2 | YesNoValue | RW | |
scalar · YesNoValue · read-write · current Determines whether or not email notification is turned on. Default is Off. | ||||
| SemailAlertLevel | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.3 | AlertSeverityLevel | RW | |
scalar · AlertSeverityLevel · read-write · current Choose the alert level that will trigger a email message to be sent if alert email is enabled. When you select an alert level, all alerts that appear above it in the list will also trigger a local event log message. For example, if you select oneTimeError, all oneTimeError, persistantError, moduleLevelFault, and systemLevelFault alert events will be generate a email message. | ||||
| SemailTo | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.4 | DisplayString (SIZE (0..64)) | RW | |
scalar · DisplayString (SIZE (0..64)) · read-write · current An email address or list of email addresses that will receive the email notification. | ||||
| SemailFrom | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.5 | DisplayString (SIZE (0..32)) | RW | |
scalar · DisplayString (SIZE (0..32)) · read-write · current This field can contain an email address that might identify the management module name or some other value. | ||||
| SemailSMTPHost | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.6 | DisplayString (SIZE (0..64)) | RW | |
scalar · DisplayString (SIZE (0..64)) · read-write · current The SMTP host (email server) that will process the email notification request. This can be either a host name defined in the management module host table or the SMTP host IP address. | ||||
| SemailReply | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.7 | DisplayString (SIZE (0..32)) | RW | |
scalar · DisplayString (SIZE (0..32)) · read-write · current The email address to whom all replies to the email notification should go. | ||||
| SemailSubject | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.8 | DisplayString (SIZE (0..48)) | RW | |
scalar · DisplayString (SIZE (0..48)) · read-write · current A text string, which can contain spaces, that will display in the Subject field of the email notification. | ||||
| SemailSMTPUsername | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.9 | DisplayString (SIZE (0..64)) | RW | |
scalar · DisplayString (SIZE (0..64)) · read-write · current The user name for the SMTP server, if the server requires authentication. | ||||
| SemailSMTPPassword | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.10 | DisplayString (SIZE (0..64)) | RW | |
scalar · DisplayString (SIZE (0..64)) · read-write · current The password for the SMTP server, if the server requires authentication. | ||||
| SemailSMTPEncryption | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.11 | INTEGER | RW | |
scalar · INTEGER · read-write · current The encryption method for the SMTP server.
| ||||
| SemailSMTPValidatePeerCertificate | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.12 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Validate peer SSL/TLS certificate, when SSL or TLS encryption is used. | ||||
| SemailSMTPTcpPort | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.13 | Integer32 (1..65535) | RW | |
scalar · Integer32 (1..65535) · read-write · current The TCP port used for communicating with the SMTP server. For no encryption or TLS encryption, use port 25. For SSL encryption, use port 465. | ||||
| SemailSMTPDomain | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.14 | DisplayString (SIZE (0..32)) | RW | |
scalar · DisplayString (SIZE (0..32)) · read-write · current The domain for NTLM authentication with the SMTP server, if applicable. | ||||
| NmgtUsersGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.4 | |||
| SmgtUsersStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.4.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SmgtUsersByPassLoginEnabled | 1.3.6.1.4.1.1966.21.1.1.1.2.4.2 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Indicates whether by pass login is enabled. When enable users will be automatically login as admin user. The will not be prompted for a user ID or password when accessing the management module. | ||||
| SmgtUsersPrimaryAuthMethod | 1.3.6.1.4.1.1966.21.1.1.1.2.4.3 | INTEGER | RW | |
scalar · INTEGER · read-write · current The first authentication method that the management module attempts. Some type of authentication must be done by the management module.
| ||||
| SmgtUsersSecondaryAuthMethod | 1.3.6.1.4.1.1966.21.1.1.1.2.4.4 | INTEGER | RW | |
scalar · INTEGER · read-write · current If the Primary Authentication Method fails, the next authentication method that the management module attempts. You can choose to use authentication methods in combination. For example, you can specify the Primary Authentication Method as Local and the Secondary Authentication Method as RADIUS. Therefore, some users can be defined in the Device Server (Local) others in RADIUS.
| ||||
| SmgtUsersAlwaysAttemptSecond | 1.3.6.1.4.1.1966.21.1.1.1.2.4.5 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current If enabled, the secondary authentication method will always be used. | ||||
| TlocalUserAccountsTable | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6 | NA | ||
table · not-accessible · current Table of locally defined user information | ||||
| RlocalUserAccountsEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to separate user defined locally.
| ||||
| CuserIndex | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.1 | GenericTableIndex | NA | |
column · GenericTableIndex · not-accessible · current The table entry number for this user. | ||||
| CuserStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.2 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| CuserName | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.3 | DisplayString (SIZE (0..16)) | RW | |
column · DisplayString (SIZE (0..16)) · read-write · current The user name. To delete a user, set this field to blank. If blank, this entry is currently unused. | ||||
| CuserPassword | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.4 | DisplayString (SIZE (0..64)) | RW | |
column · DisplayString (SIZE (0..64)) · read-write · current The password for the local user. | ||||
| CuserLevel | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current Admin: Total access to the management module. More than one admin user account can exist, but we recommend that you only have one. operator: Full read only access to configuration and limited control commands
| ||||
| TlocalUsersStatusTable | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7 | NA | ||
table · not-accessible · current Table of locally defined user information | ||||
| RlocalUsersStatusEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to separate user defined locally.
| ||||
| CuserStatusIndex | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.1 | GenericTableIndex | NA | |
column · GenericTableIndex · not-accessible · current The table entry number for this user status. | ||||
| CuserStatusName | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.2 | DisplayString (SIZE (0..16)) | RO | |
column · DisplayString (SIZE (0..16)) · read-only · current The user name. To delete a user, set this field to blank. If blank, this entry is currently unused. | ||||
| CuserStatusMgtAccessType | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.3 | INTEGER | NA | |
column · INTEGER · not-accessible · current Defines the management protocol used to access the management module
| ||||
| CuserStatusRemoteIPAddress | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.4 | Ipv4v6Address | RO | |
column · Ipv4v6Address · read-only · current This object specifies the remote IP address user management session. | ||||
| CuserStatusStartTime | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.5 | DisplayString | RO | |
column · DisplayString · read-only · current This object identifies the date and time that the current user's management session started. | ||||
| CuserStatusLevel | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current Admin: Total access to the management module. More than one admin user account can exist, but we recommend that you only have one. operator: Full read only access to configuration and limited control commands
| ||||
| NradiusGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8 | |||
| SradiusStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SradiusPrimaryAuthHost | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.2 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current Primary Radius Authentication Host | ||||
| SradiusSecondaryAuthHost | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.3 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current Secondary Radius Authentication Host | ||||
| SradiusAuthenticationPort | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.4 | Integer32 (0..65535) | RW | |
scalar · Integer32 (0..65535) · read-write · current The port that the RADIUS host listens to for authentication requests. The default port is 1812. | ||||
| SradiusAccounting | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.5 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Radius Accounting | ||||
| SradiusPrimaryAcctHost | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.6 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current Name of the primary RADIUS authentication host. | ||||
| SradiusSecondaryAcctHost | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.7 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current Name of the secondary RADIUS authentication host. | ||||
| SradiusAccountingPort | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.8 | Integer32 (0..65535) | RW | |
scalar · Integer32 (0..65535) · read-write · current The port that the RADIUS host listens to for accounting requests. The default port is 1813. | ||||
| SradiusAcctAuth | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.9 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Radius Accounting Authenticator | ||||
| SradiusRetryLimit | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.10 | Integer32 (0..255) | RW | |
scalar · Integer32 (0..255) · read-write · current The number of times the management module tries to connect to the RADIUS server before erroring out. Valid values are 0-255. The default is 5. | ||||
| SradiusTimeout | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.11 | Integer32 (1..255) | RW | |
scalar · Integer32 (1..255) · read-write · current The time, in seconds, that the management module waits to receive a reply after sending out a request to a RADIUS accounting or authentication host. If no reply is received before the timeout period expires, the management module will retry the same host up to and including the number of retry attempts. Valid values are 1-255. The default is 3 seconds. | ||||
| SradiusNasIdentifier | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.12 | DisplayString (SIZE (0..32)) | RW | |
scalar · DisplayString (SIZE (0..32)) · read-write · current The NAS identifier name. To delete this , set this field to blank. | ||||
| SradiusNasIpAddress | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.13 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current When on, the NAS Identifier obtains ipv4 address automatically. Default is on. | ||||
| SradiusNasSpecifyIpAddress | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.14 | IpAddress | RW | |
scalar · IpAddress · read-write · current Specify the unique IPv4 address that NAS Identifier will use | ||||
| SradiusNasIpv6Address | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.15 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current When on, the NAS Identifier obtains ipv6 address automatically. Default is on. | ||||
| SradiusNasSpecifyIpv6Address | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.16 | DisplayString | RW | |
scalar · DisplayString · read-write · current Specify the unique IPv6 address that NAS Identifier will use | ||||
| NkerberosGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.4.9 | |||
| SkerberosStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.4.9.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SkerberosRealm | 1.3.6.1.4.1.1966.21.1.1.1.2.4.9.2 | DisplayString (SIZE (0..32)) | RW | |
scalar · DisplayString (SIZE (0..32)) · read-write · current The Kerberos realm is the Kerberos host domain name, in upper-case letters. | ||||
| SkerberosDomain | 1.3.6.1.4.1.1966.21.1.1.1.2.4.9.3 | DisplayString (SIZE (0..32)) | RW | |
scalar · DisplayString (SIZE (0..32)) · read-write · current The name of a host running the KDC (Key Distribution Center) for the specified realm. The host name that you specify must either be defined in the management module's host Table before the last reboot or be resolved by DNS. | ||||
| SkerberosPort | 1.3.6.1.4.1.1966.21.1.1.1.2.4.9.4 | Integer32 (0..65535) | RW | |
scalar · Integer32 (0..65535) · read-write · current The port that the Kerberos server listens to for authentication requests. If no port is specified, the default port 88 is used. | ||||
| NldapGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10 | |||
| SldapStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SldapHost | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.2 | DisplayString (SIZE (0..64)) | RW | |
scalar · DisplayString (SIZE (0..64)) · read-write · current The name or IP address of the LDAP host. If you use
a host name, that host must either have been defined
in the management module's Host Table before the last
reboot or be resolved by DNS. If you are using TLS,
you must enter the same string you used to create
the LDAP certificate. | ||||
| SldapPort | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.3 | Integer32 (0..65535) | RW | |
scalar · Integer32 (0..65535) · read-write · current The port that the LDAP host listens to for authentication requests. The default port is 389. | ||||
| SldapBase | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.4 | DisplayString (SIZE (0..64)) | RW | |
scalar · DisplayString (SIZE (0..64)) · read-write · current The domain component (dc) that is the starting point for the search for user authentication. | ||||
| SldapEnableTLS | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.5 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Enables/disables the Transport Layer Security (TLS) with the LDAP host. | ||||
| SldapTLSPort | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.6 | Integer32 (0..65535) | RW | |
scalar · Integer32 (0..65535) · read-write · current Specify the port number that LDAP will use for TLS. The default is port 636. | ||||
| SldapUID | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.7 | DisplayString (SIZE (0..32)) | RW | |
scalar · DisplayString (SIZE (0..32)) · read-write · current LDAP user attribute. e.g. uid (OpenLDAP) sAMAccountName (Active Directory) The default is 'uid'. | ||||
| SldapPasswordEncryption | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.8 | INTEGER | RW | |
scalar · INTEGER · read-write · current LDAP password encryption method.
| ||||
| SldapClientAuth | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.9 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current LDAP client authentication. | ||||
| SldapClientName | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.10 | DisplayString (SIZE (0..64)) | RW | |
scalar · DisplayString (SIZE (0..64)) · read-write · current LDAP client name. Identifies the unit to the LDAP server, when client authentication is . | ||||
| SldapClientAppendBase | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.11 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Append base to LDAP client name. | ||||
| SldapClientPassword | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.12 | DisplayString (SIZE (0..64)) | RW | |
scalar · DisplayString (SIZE (0..64)) · read-write · current LDAP client password. Identifies the unit to the LDAP server, when client authentication is . | ||||
| NtacacsGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11 | |||
| StacacsStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| StacacsPrimaryHost | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.2 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current The primary TACACS+ host that is used for authentication. | ||||
| StacacsSecondaryHost | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.3 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current The secondary TACACS+ host that is used for authentication, should the primary TACACS+ host fail to respond. | ||||
| StacacsPort | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.4 | Integer32 (0..65535) | RW | |
scalar · Integer32 (0..65535) · read-write · current The port number that TACACS+ listens to for authentication requests. The default port number is 49. | ||||
| StacacsAccounting | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.5 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Enable/Disable TACACS+ accounting | ||||
| StacacsAccountingPrimaryHost | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.6 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current The primary TACACS+ accounting host that is used for. | ||||
| StacacsAccountingSecondaryHost | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.7 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current The secondary TACACS+ accounting host that is used for , should the primary TACACS+ host fail to respond. | ||||
| StacacsAccountingPort | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.8 | Integer32 (0..65535) | RW | |
scalar · Integer32 (0..65535) · read-write · current The port number that TACACS+ listens to for accounting requests. The default port number is 49. | ||||
| StacacsAuthorization | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.9 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Enable/Disable TACACS+ authorization | ||||
| StacacsAlternateServiceNames | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.10 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Enable alternate service names for TACACS+. | ||||
| NsecuridGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12 | |||
| SsecuridStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SsecuridMasterHost | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12.2 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current The first SecurID server that is tried for user authentication. | ||||
| SsecuridSlaveHost | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12.3 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current If the first SecurID server does not respond to an authentication request, this is the next SecurID server that is tried for user authentication. | ||||
| SsecuridPort | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12.4 | Integer32 (0..65535) | RW | |
scalar · Integer32 (0..65535) · read-write · current The port number that SecurID listens to for authentication requests. The default port number is 5500. | ||||
| SsecuridType | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12.5 | INTEGER | RW | |
scalar · INTEGER · read-write · current You can specify either SDI or DES encryption for SecurID server communication. The default is SDI encryption.
| ||||
| SsecuridLegacy | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12.6 | YesNoValue | RW | |
scalar · YesNoValue · read-write · current If you are running SecurID 3.x or 4.x, you need to run in Legacy Mode. If you are running SecurID 5.x or above, do not select Legacy Mode. | ||||
| NnisGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.4.13 | |||
| SnisStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.4.13.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SnisDomain | 1.3.6.1.4.1.1966.21.1.1.1.2.4.13.2 | DisplayString (SIZE (0..32)) | RW | |
scalar · DisplayString (SIZE (0..32)) · read-write · current The NIS domain name. | ||||
| SnisPrimaryHost | 1.3.6.1.4.1.1966.21.1.1.1.2.4.13.3 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current The primary NIS host that is used for authentication. | ||||
| SnisSecondaryHost | 1.3.6.1.4.1.1966.21.1.1.1.2.4.13.4 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current The secondary NIS host that is used for authentication, should the primary NIS host fail to respond. | ||||
| NmgtDateTimeGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.5 | |||
| SmgtDateTimeStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.5.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SsystemDate | 1.3.6.1.4.1.1966.21.1.1.1.2.5.2 | DisplayString | RW | |
scalar · DisplayString · read-write · current The system date. Format dd/mm/yyyy. | ||||
| SsystemTime | 1.3.6.1.4.1.1966.21.1.1.1.2.5.3 | DisplayString | RW | |
scalar · DisplayString · read-write · current The system time (local time). Format hh:mm:ss. | ||||
| SsystemDateTimeAndOffset | 1.3.6.1.4.1.1966.21.1.1.1.2.5.4 | DisplayString | RO | |
scalar · DisplayString · read-only · current This read only object identifies the current system date, time and GMT offset. The date and time will be displayed in the regional time format configured. | ||||
| StimeZoneListEnable | 1.3.6.1.4.1.1966.21.1.1.1.2.5.5 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current When the time zone list is enabled then the time zone being use is the one selected form the predefined list of time zones. If not enabled then the customTimeZoneGroup will define the time zone being used | ||||
| SselectionFromTimeZoneList | 1.3.6.1.4.1.1966.21.1.1.1.2.5.6 | INTEGER | RW | |
scalar · INTEGER · read-write · current This object identifies the predefined time zone selected. This time zone will be used if timeZoneListEnable object is set to yes. configured.
| ||||
| StimeZoneAdjustForDST | 1.3.6.1.4.1.1966.21.1.1.1.2.5.7 | YesNoValue | RW | |
scalar · YesNoValue · read-write · current This object identifies if the time will be adjusted for DST (Daylight Savings Time) or not. | ||||
| NcustomTimeZoneGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8 | |||
| ScustomTimeZoneStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of
the following values will be returned:
1-Indicates that the container folder is active with no changes.
2-Indicates that the container folder is active with change(s).
Once you have completed setting the variables in a folder, you
will want to submit your changes to the management module. To do
this, set the Status variable to 4. If you want to discard the
changes, set the Status variable to 6.
4-Indicates that the changes in the container folder are to be
submitted to the management module and verified. To save the
changes to flash a write of writeToFlash(1) in the adminFunction
object is required.
6-Indicates that the changes in the container folder are to be
discarded. | ||||
| StimeZoneName | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.2 | DisplayString (SIZE (0..4)) | RW | |
scalar · DisplayString (SIZE (0..4)) · read-write · current The name of the time zone when using standard time. | ||||
| StimeOffset | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.3 | Integer32 (-720..840) | RW | |
scalar · Integer32 (-720..840) · read-write · current The offset of summer time from standard time in minutes. | ||||
| StimeSummerName | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.4 | DisplayString (SIZE (0..4)) | RW | |
scalar · DisplayString (SIZE (0..4)) · read-write · current The name of the time zone when using summer time. | ||||
| StimeSummerOffset | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.5 | Integer32 (0..180) | RW | |
scalar · Integer32 (0..180) · read-write · current The offset of summer time from standard time in minutes. | ||||
| StimeSummerMode | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.6 | INTEGER | RW | |
scalar · INTEGER · read-write · current You can configure the summer time to take effect:
None-No summer time change.
Fixed-The summer time change goes into effect at
the specified time every year. For example,
April 15 at 1:00 pm.
Recurring-The summer time changes goes into effect
every year at same relative time. For example,
on the third week in April on a Tuesday at 1:00 pm.
| ||||
| StimeSummerRecStartMonth | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.7 | INTEGER | RW | |
scalar · INTEGER · read-write · current The recurring summer time start month.
| ||||
| StimeSummerRecStartWeek | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.8 | INTEGER | RW | |
scalar · INTEGER · read-write · current The recurring summer time start week.
| ||||
| StimeSummerRecStartDay | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.9 | INTEGER | RW | |
scalar · INTEGER · read-write · current The recurring summer time start day.
| ||||
| StimeSummerRecStartHour | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.10 | Integer32 (0..23) | RW | |
scalar · Integer32 (0..23) · read-write · current The recurring summer time start hour. | ||||
| StimeSummerRecStartMin | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.11 | Integer32 (0..59) | RW | |
scalar · Integer32 (0..59) · read-write · current The recurring summer time start minute | ||||
| StimeSummerRecEndMonth | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.12 | INTEGER | RW | |
scalar · INTEGER · read-write · current The recurring summer time end month.
| ||||
| StimeSummerRecEndWeek | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.13 | INTEGER | RW | |
scalar · INTEGER · read-write · current The recurring summer time end week.
| ||||
| StimeSummerRecEndDay | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.14 | INTEGER | RW | |
scalar · INTEGER · read-write · current The recurring summer time end day.
| ||||
| StimeSummerRecEndHour | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.15 | Integer32 (0..23) | RW | |
scalar · Integer32 (0..23) · read-write · current The recurring summer time end hour | ||||
| StimeSummerRecEndMin | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.16 | Integer32 (0..59) | RW | |
scalar · Integer32 (0..59) · read-write · current The recurring summer time end minute | ||||
| StimeSummerFixStartMonth | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.17 | INTEGER | RW | |
scalar · INTEGER · read-write · current The fixed summer time start month
| ||||
| StimeSummerFixStartDay | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.18 | Integer32 (1..31) | RW | |
scalar · Integer32 (1..31) · read-write · current The fixed summer time start day | ||||
| StimeSummerFixStartHour | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.19 | Integer32 (0..23) | RW | |
scalar · Integer32 (0..23) · read-write · current The fixed summer time start hour | ||||
| StimeSummerFixStartMinute | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.20 | Integer32 (0..59) | RW | |
scalar · Integer32 (0..59) · read-write · current The fixed summer time start minute | ||||
| StimeSummerFixEndMonth | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.21 | INTEGER | RW | |
scalar · INTEGER · read-write · current The fixed summer time End month
| ||||
| StimeSummerFixEndDay | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.22 | Integer32 (1..31) | RW | |
scalar · Integer32 (1..31) · read-write · current The fixed summer time End day | ||||
| StimeSummerFixEndHour | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.23 | Integer32 (0..23) | RW | |
scalar · Integer32 (0..23) · read-write · current The fixed summer time End hour | ||||
| StimeSummerFixEndMinute | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.24 | Integer32 (0..59) | RW | |
scalar · Integer32 (0..59) · read-write · current The fixed summer time End minute | ||||
| NnetworkTimeGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9 | |||
| StimeStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| StimeSntpMode | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.2 | INTEGER | RW | |
scalar · INTEGER · read-write · current The SNTP client mode. Valid modes are Disabled, Unicast, Multicast or Anycast
| ||||
| StimeSntpVersion | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.3 | INTEGER | RW | |
scalar · INTEGER · read-write · current The sntp client version.
| ||||
| StimeSntpHost1 | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.4 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current The first remote SNTP host name that the device server communicates with. | ||||
| StimeSntpHost2 | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.5 | DisplayString (SIZE (0..14)) | RW | |
scalar · DisplayString (SIZE (0..14)) · read-write · current The second remote SNTP host name that the device server communicates with. | ||||
| NsntpStatGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6 | |||
| SsntpStatAddress | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.1 | DisplayString | RO | |
scalar · DisplayString · read-only · current The address of the remote SNMP host that updated the time. | ||||
| SsntpStatLastUpdate | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.2 | DisplayString | RO | |
scalar · DisplayString · read-only · current The time of the last update. | ||||
| SsntpStatLeapIndicator | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.3 | INTEGER | RO | |
scalar · INTEGER · read-only · current The leap year indicator.
| ||||
| SsntpStatVersion | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.4 | INTEGER | RO | |
scalar · INTEGER · read-only · current The SNTP version.
| ||||
| SsntpStatMode | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.5 | INTEGER | RO | |
scalar · INTEGER · read-only · current The current SNTP mode
| ||||
| SsntpStatStratum | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.6 | Integer32 (0..15) | RO | |
scalar · Integer32 (0..15) · read-only · current The SNTP stratum. | ||||
| SsntpStatRefId | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.7 | Unsigned32 | RO | |
scalar · Unsigned32 · read-only · current The SNTP reference ID. | ||||
| SsntpStatOffset | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.8 | Unsigned32 | RO | |
scalar · Unsigned32 · read-only · current The SNTP offset | ||||
| StimeSntpServerAuthentication | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.7 | INTEGER | RW | |
scalar · INTEGER · read-write · current Specifies whether to authenticate with the ntp time server.
| ||||
| StimeSntpKeyID | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.8 | INTEGER | RW | |
scalar · INTEGER · read-write · current Specifies the key ID to use for host 1 during server authentication. | ||||
| StimeSntpKeyID2 | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.9 | INTEGER | RW | |
scalar · INTEGER · read-write · current Specifies the key ID to use for host 2 during server authentication. | ||||
| NmgtFilesGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.6 | |||
| NmgtBootFilesGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.6.1 | |||
| SbootFileStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.6.1.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SfileFirmwareHost | 1.3.6.1.4.1.1966.21.1.1.1.2.6.1.2 | DisplayString (SIZE (0..46)) | RW | |
scalar · DisplayString (SIZE (0..46)) · read-write · current The host name or IP address of the server that contains the firmware file. If you use a host name, it must exist in the management module's host table or be resolved by DNS. | ||||
| SfileFirmwareName | 1.3.6.1.4.1.1966.21.1.1.1.2.6.1.3 | DisplayString (SIZE (0..64)) | RW | |
scalar · DisplayString (SIZE (0..64)) · read-write · current The path and file name (do not use a drive letter), relative to the default path of your TFTP server software, of the update software for the management module that will be loaded when the management module is rebooted. | ||||
| SfileConfigurationHost | 1.3.6.1.4.1.1966.21.1.1.1.2.6.1.4 | DisplayString (SIZE (0..46)) | RW | |
scalar · DisplayString (SIZE (0..46)) · read-write · current The host name or IP address of the server that contains the configuration file. If you use a host name, it must exist in the management module's host table or be resolved by DNS. | ||||
| SfileConfigurationName | 1.3.6.1.4.1.1966.21.1.1.1.2.6.1.5 | DisplayString (SIZE (0..64)) | RW | |
scalar · DisplayString (SIZE (0..64)) · read-write · current The path and file name (do not use a drive letter), relative to the default path of your TFTP server software, of the new configuration file for the Device Server that will be loaded when the management module is rebooted. | ||||
| NmgtfirmwareUpdatesGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2 | |||
| SfirmwareUpdateStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| SfirmwareUpdateAuto | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.2 | OnOffValue | RW | |
scalar · OnOffValue · read-write · current Enable automatic updates of installed media converter modules from firmware bundle on management module.. | ||||
| SfirmwareUpdateBundleVersionCm100 | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.3 | DisplayString | RO | |
scalar · DisplayString · read-only · current This object identifies the bundled firmware version for CM-100 modules. | ||||
| SfirmwareUpdateBundleVersionCm110 | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.4 | DisplayString | RO | |
scalar · DisplayString · read-only · current This object identifies the bundled firmware version for CM-110 modules. | ||||
| SfirmwareUpdateBundleVersionCm1000OrCm1000Sfp | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.5 | DisplayString | RO | |
scalar · DisplayString · read-only · current This object identifies the bundled firmware version for CM-1000 or CM-1000-SFP modules. | ||||
| SfirmwareUpdateBundleVersionCm1110 | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.6 | DisplayString | RO | |
scalar · DisplayString · read-only · current This object identifies the bundled firmware version for CM-1110 modules. | ||||
| SfirmwareUpdateBundleVersionCm1110Sfp | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.7 | DisplayString | RO | |
scalar · DisplayString · read-only · current This object identifies the bundled firmware version for CM-1110-SFP modules. | ||||
| SfirmwareUpdateBundleVersionCm100mm | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.8 | DisplayString | RO | |
scalar · DisplayString · read-only · current This object identifies the bundled firmware version for CM-100MM modules. | ||||
| SfirmwareUpdateBundleVersionCm1000mm | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.9 | DisplayString | RO | |
scalar · DisplayString · read-only · current This object identifies the bundled firmware version for CM-1000MM modules. | ||||
| SfirmwareUpdateBundleVersionCm10g | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.10 | DisplayString | RO | |
scalar · DisplayString · read-only · current This object identifies the bundled firmware version for CM-10G modules. | ||||
| TnettxfrTable | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3 | NA | ||
table · not-accessible · current Table of snmp file transfer sessions. | ||||
| RnettxfrEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a SNMP file transfer session.
| ||||
| CnettxfrSessionID | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.1 | Unsigned32 | NA | |
column · Unsigned32 · not-accessible · current This indicates if the net transfer is to be loaded to the management module or saved from the management module. | ||||
| CnettxfrStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.2 | INTEGER | RW | |
column · INTEGER · read-write · current This field indicates the status of the nettxfr process. A value of start(1) should be written to this field to start the nettxfr process with the specified parameters in the rest of this group.
| ||||
| CnettxfrDirection | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.3 | INTEGER | RW | |
column · INTEGER · read-write · current This indicates if the net transfer is to be loaded to the management module or saved from the management module.
| ||||
| CnettxfrFileType | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.4 | INTEGER | RW | |
column · INTEGER · read-write · current This indicates the type of file to be transfered to/from the management module.
| ||||
| CnettxfrFileHost | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.5 | DisplayString (SIZE (0..46)) | RW | |
column · DisplayString (SIZE (0..46)) · read-write · current The host name or IP address of the server that contains the file to be transfered to/from the management module.. If you use a host name, it must exist in the management module's host table or be resolved by DNS. | ||||
| CnettxfrFileName | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.6 | DisplayString (SIZE (0..64)) | RW | |
column · DisplayString (SIZE (0..64)) · read-write · current The path and file name (do not use a drive letter), relative to the default path of your TFTP server software, of the file to be transfered to/from the management module. | ||||
| CnettxfrMCSlotNumber | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.7 | SlotNumber | RW | |
column · SlotNumber · read-write · current Specifies the slot number of the Media Converter Module to which the firmware will be transfered. | ||||
| CnettxfrUserName | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.8 | DisplayString (SIZE (0..64)) | RW | |
column · DisplayString (SIZE (0..64)) · read-write · current Specifies the user login name who owns the ssh public key that is to be transfered to the management module. | ||||
| CnettxfrSSHKeyType | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.9 | INTEGER | RW | |
column · INTEGER · read-write · current Specifies the authentication method used by the ssh-server public key that is to be transfered to/from the management module
| ||||
| CnettxfrSSLType | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.10 | INTEGER | RW | |
column · INTEGER · read-write · current Specifies the type of SSL file to be transfered to the management module. These files are needed if you are using the secure version of the WebManager (HTTPS), or LDAP authentication with TLS.
| ||||
| CnettxfrSessionInUse | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.11 | INTEGER | RW | |
column · INTEGER · read-write · current Specifies whether this net transfer session entry is in use. If a manager tries to write a 1 to this field and the session is already in use, then an error is returned.
| ||||
| CnettxfrTftpPort | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.12 | Unsigned32 (1..65536) | RW | |
column · Unsigned32 (1..65536) · read-write · current Specifies a UDP port number for the TFTP host server. Default is 69. | ||||
| NmgtAdminGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.7 | |||
| SadminFunction | 1.3.6.1.4.1.1966.21.1.1.1.2.7.1 | INTEGER | RW | |
scalar · INTEGER · read-write · current Perform a specific function on the management module. If you want to save all the changes that have been submitted to the management module, you need to expand the adminGroup container folder and SET the adminFunction to 1 to write to FLASH. To make the configuration changes take effect, SET the adminFunction to 3 to reboot the management module.
| ||||
| SadminLastFunction | 1.3.6.1.4.1.1966.21.1.1.1.2.7.2 | INTEGER | RO | |
scalar · INTEGER · read-only · current The last function requested
| ||||
| SadminStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.7.3 | INTEGER | RO | |
scalar · INTEGER · read-only · current The status of the last function performed.
| ||||
| SadminbootReason | 1.3.6.1.4.1.1966.21.1.1.1.2.7.4 | Bits | RO | |
scalar · Bits · read-only · current The reason(s) why the management module last rebooted.
| ||||
| SadminDiagFileAvailable | 1.3.6.1.4.1.1966.21.1.1.1.2.7.5 | YesNoValue | RO | |
scalar · YesNoValue · read-only · current This object indicates that a diagnostic file is available. | ||||
| NmgtDisplayFormatGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.8 | |||
| SdisplayFormatStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.8.1 | ContainerStatus | RW | |
scalar · ContainerStatus · read-write · current When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | ||||
| ScfgTemperatureUnits | 1.3.6.1.4.1.1966.21.1.1.1.2.8.2 | INTEGER | RW | |
scalar · INTEGER · read-write · current This object identifies the units to display any internally measured temperature. The units can be Celsius or Fahrenheit.
| ||||
| ScfgSfpPowerUnits | 1.3.6.1.4.1.1966.21.1.1.1.2.8.3 | INTEGER | RW | |
scalar · INTEGER · read-write · current This object identifies the units to display any SFP DMI internally measured transmit/receive power. The units can be milliwatts (mW) or Decibel milliwatts (dBm).
| ||||
| ScfgTimeFormat | 1.3.6.1.4.1.1966.21.1.1.1.2.8.4 | INTEGER | RW | |
scalar · INTEGER · read-write · current This object identifies the format to display the time.
| ||||
| ScfgDateFormat | 1.3.6.1.4.1.1966.21.1.1.1.2.8.5 | INTEGER | RW | |
scalar · INTEGER · read-write · current This object identifies the format to display date.
| ||||
| NmgtChassisCfgGroup | 1.3.6.1.4.1.1966.21.1.1.1.2.9 | |||
| TmgtChassisSlotPowerScheduleTable | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1 | NA | ||
table · not-accessible · current Table of power schedule configuration for chassis slots. (Not applicable to 2-slot chassis.) | ||||
| RmgtChassisSlotPowerScheduleEntry | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1 | NA | ||
row · not-accessible · current Entries of the table, each relating to a separate slot in a chassis. | ||||
| CpowerSchedSlotIndex | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.2 | SlotNumber | NA | |
column · SlotNumber · not-accessible · current This object identifies the chassis slot number. | ||||
| CpowerSchedDayOfWeek | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.3 | INTEGER | NA | |
column · INTEGER · not-accessible · current This object identifies the day of the week.
| ||||
| CpowerSchedConifgStatus | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.4 | ContainerStatus | RW | |
column · ContainerStatus · read-write · current When you perform a GET on this variable, one of
the following values will be returned:
1-Indicates that the container folder is active with no changes.
2-Indicates that the container folder is active with change(s).
Once you have completed setting the variables in a folder, you
will want to submit your changes to the management module. To do
this, set the Status variable to 4. If you want to discard the
changes, set the Status variable to 6.
4-Indicates that the changes in the container folder are to be
submitted to the management module and verified. To save the
changes to flash a write of writeToFlash(1) in the adminFunction
object is required.
6-Indicates that the changes in the container folder are to be
discarded. | ||||
| CpowerSchedOnHour | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.5 | INTEGER (0..23) | RW | |
column · INTEGER (0..23) · read-write · current This object identifies the hour (0-23) of the day to schedule a power on of the chassis slot | ||||
| CpowerSchedOnMinute | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.6 | INTEGER (0..59) | RW | |
column · INTEGER (0..59) · read-write · current This object identifies the minute (0-59) of the hour to schedule a power on of the chassis slot | ||||
| CpowerSchedOffHour | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.7 | INTEGER (0..23) | RW | |
column · INTEGER (0..23) · read-write · current This object identifies the hour (0-23) of the day to schedule a power off of the chassis slot | ||||
| CpowerSchedOffMinute | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.8 | INTEGER (0..59) | RW | |
column · INTEGER (0..59) · read-write · current This object identifies the minute (0-59) of the hour to schedule a power off of the chassis slot | ||||
| NmcrMGTMIBConformance | 1.3.6.1.4.1.1966.21.1.1.2 | |||
| NmcrMGTMIBCompliances | 1.3.6.1.4.1.1966.21.1.1.2.1 | |||
| MmcrMGTMIBCompliance | 1.3.6.1.4.1.1966.21.1.1.2.1.1 | |||
compliance · current The compliance statement for mcrMGT which implement the Perle Managed Media Converters MIB. | ||||
| NmcrMGTMIBGroups | 1.3.6.1.4.1.1966.21.1.1.2.2 | |||
| GmcrMGTMIBChassisGroup | 1.3.6.1.4.1.1966.21.1.1.2.2.1 | |||
group · current The group of objects for identifying and determining the configuration and current timeliness values of the Perle Managed Media Converters chassis.
| ||||
| GmcrMGTMIBMediaGroup | 1.3.6.1.4.1.1966.21.1.1.2.2.2 | |||
group · current The group of objects for identifying and determining the configuration and current timeliness values of the Perle Managed Media Converters media converter modules
| ||||
| GmcrMGTMIBMgtGroup | 1.3.6.1.4.1.1966.21.1.1.2.2.3 | |||
group · current The group of objects for identifying and determining the configuration and current timeliness values of the Perle Managed Media Converters media converter modules
| ||||
| GmcrMGTMIBNotificationsGroup | 1.3.6.1.4.1.1966.21.1.1.2.2.4 | |||
group · current The group of notifications (traps) which is implemented for the Perle Managed Media Converters.
| ||||
Textual conventions
AlertSeverityLevelINTEGERmoduleLevelFault(1)normalOperation(5)oneTimeError(3)persistantError(2)significantEvent(4)systemLevelFault(0)The alert severity level of an event.
ContainerStatusINTEGERactive(1)applyChanges(4)discardChanges(6)modified(2)When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module. 6-Indicates that the changes in the container folder are to be discarded.
EnableDisableValueINTEGERdisable(0)enable(1)notApplicable(-1)Represents an ON or OFF value.
GenericTableIndexUnsigned32 (1..2147483647)Display hint:
dAn arbitrary value that uniquely identifies the entity. The value should be a small, positive integer. Index values for different entities are not necessarily contiguous.
Ipv4v6AddressOCTET STRING (SIZE (0..255))Display hint:
255aAn IPv4 or IPv6 address
OnOffValueINTEGERnotApplicable(-1)off(0)on(1)Represents an ON or OFF value.
SlotNumberUnsigned32 (1..2147483647)Display hint:
dChassis slot number. Valid values are 1 to the highest slot number the chassis supports. For example a MCR-1900 chassis the valid slot numbers are 1 to 19
YesNoValueINTEGERno(0)notApplicable(-1)yes(1)Represents a YES or NO value.
Traps / Notifications
- mcrAlarmRelayDisengaged
1.3.6.1.4.1.1966.21.1.1.0.243 - mcrAlarmRelayEngaged
1.3.6.1.4.1.1966.21.1.1.0.242 - mcrBandwidthLevelDownstreamLow
1.3.6.1.4.1.1966.21.1.1.0.246 - mcrBandwidthLevelDownstreamRecov
1.3.6.1.4.1.1966.21.1.1.0.247 - mcrBandwidthLevelUpstreamLow
1.3.6.1.4.1.1966.21.1.1.0.244 - mcrBandwidthLevelUpstreamRecov
1.3.6.1.4.1.1966.21.1.1.0.245 - mcrChassisAdd
1.3.6.1.4.1.1966.21.1.1.0.24 - mcrChassisCommTempSensorFail
1.3.6.1.4.1.1966.21.1.1.0.99 - mcrChassisCommTempSensorRecov
1.3.6.1.4.1.1966.21.1.1.0.100 - mcrChassisFail
1.3.6.1.4.1.1966.21.1.1.0.31 - mcrChassisOk
1.3.6.1.4.1.1966.21.1.1.0.32 - mcrChassisRemove
1.3.6.1.4.1.1966.21.1.1.0.25 - mcrChassisReset
1.3.6.1.4.1.1966.21.1.1.0.26 - mcrChassisSlotPoweredOff
1.3.6.1.4.1.1966.21.1.1.0.30 - mcrChassisSlotPoweredOn
1.3.6.1.4.1.1966.21.1.1.0.29 - mcrChassisTemperatureAlarm
1.3.6.1.4.1.1966.21.1.1.0.27 - mcrChassisTemperatureRecover
1.3.6.1.4.1.1966.21.1.1.0.28 - mcrLinkTestError
1.3.6.1.4.1.1966.21.1.1.0.241 - mcrMediaBadImage
1.3.6.1.4.1.1966.21.1.1.0.102 - mcrMediaConfMismatch
1.3.6.1.4.1.1966.21.1.1.0.53 - mcrMediaConfMismatchResolv
1.3.6.1.4.1.1966.21.1.1.0.54 - mcrMediaConfUpdateFail
1.3.6.1.4.1.1966.21.1.1.0.51 - mcrMediaConfUpdateSuccess
1.3.6.1.4.1.1966.21.1.1.0.52 - mcrMediaDetectFail
1.3.6.1.4.1.1966.21.1.1.0.101 - mcrMediaFail
1.3.6.1.4.1.1966.21.1.1.0.47 - mcrMediaFirmwareUpdateFail
1.3.6.1.4.1.1966.21.1.1.0.55 - mcrMediaFirmwareUpdateSuccess
1.3.6.1.4.1.1966.21.1.1.0.56 - mcrMediaInserted
1.3.6.1.4.1.1966.21.1.1.0.42 - mcrMediaLinkDown
1.3.6.1.4.1.1966.21.1.1.0.50 - mcrMediaLinkUp
1.3.6.1.4.1.1966.21.1.1.0.49 - mcrMediaLostCommunication
1.3.6.1.4.1.1966.21.1.1.0.45 - mcrMediaOk
1.3.6.1.4.1.1966.21.1.1.0.48 - mcrMediaRecovCommunication
1.3.6.1.4.1.1966.21.1.1.0.46 - mcrMediaRemoteReset
1.3.6.1.4.1.1966.21.1.1.0.248 - mcrMediaRemoved
1.3.6.1.4.1.1966.21.1.1.0.43 - mcrMediaReset
1.3.6.1.4.1.1966.21.1.1.0.44 - mcrMgtAuthFail
1.3.6.1.4.1.1966.21.1.1.0.8 - mcrMgtAuthSuccess
1.3.6.1.4.1.1966.21.1.1.0.9 - mcrMgtChassisMismatch
1.3.6.1.4.1.1966.21.1.1.0.23 - mcrMgtConMonDSRSigChg
1.3.6.1.4.1.1966.21.1.1.0.7 - mcrMgtConfSavedFlash
1.3.6.1.4.1.1966.21.1.1.0.17 - mcrMgtDateTimeChg
1.3.6.1.4.1.1966.21.1.1.0.10 - mcrMgtEmailServFail
1.3.6.1.4.1.1966.21.1.1.0.15 - mcrMgtEmailServRec
1.3.6.1.4.1.1966.21.1.1.0.16 - mcrMgtEtheLinkDown
1.3.6.1.4.1.1966.21.1.1.0.6 - mcrMgtEtheLinkUp
1.3.6.1.4.1.1966.21.1.1.0.5 - mcrMgtIpAddrDynChg
1.3.6.1.4.1.1966.21.1.1.0.18 - mcrMgtModuleInserted
1.3.6.1.4.1.1966.21.1.1.0.1 - mcrMgtReset
1.3.6.1.4.1.1966.21.1.1.0.3 - mcrMgtResetFactory
1.3.6.1.4.1.1966.21.1.1.0.4 - mcrMgtSnmpTrapHostFail
1.3.6.1.4.1.1966.21.1.1.0.13 - mcrMgtSnmpTrapHostRec
1.3.6.1.4.1.1966.21.1.1.0.14 - mcrMgtSntpServFail
1.3.6.1.4.1.1966.21.1.1.0.11 - mcrMgtSntpServRec
1.3.6.1.4.1.1966.21.1.1.0.12 - mcrMgtSystemBoot
1.3.6.1.4.1.1966.21.1.1.0.2 - mcrMgtTftpDownloadFail
1.3.6.1.4.1.1966.21.1.1.0.21 - mcrMgtTftpDownloadSuccess
1.3.6.1.4.1.1966.21.1.1.0.22 - mcrMgtTftpUploadFail
1.3.6.1.4.1.1966.21.1.1.0.19 - mcrMgtTftpUploadSuccess
1.3.6.1.4.1.1966.21.1.1.0.20 - mcrModuleFirmwareUpdate
1.3.6.1.4.1.1966.21.1.1.0.106 - mcrModuleNotSupported
1.3.6.1.4.1.1966.21.1.1.0.105 - mcrPsmuFanFail
1.3.6.1.4.1.1966.21.1.1.0.39 - mcrPsmuFanOk
1.3.6.1.4.1.1966.21.1.1.0.40 - mcrPsmuInserted
1.3.6.1.4.1.1966.21.1.1.0.33 - mcrPsmuPsuFail
1.3.6.1.4.1.1966.21.1.1.0.35 - mcrPsmuPsuOk
1.3.6.1.4.1.1966.21.1.1.0.36 - mcrPsmuPsuVoltageFail
1.3.6.1.4.1.1966.21.1.1.0.37 - mcrPsmuPsuVoltageOk
1.3.6.1.4.1.1966.21.1.1.0.38 - mcrPsmuRemoved
1.3.6.1.4.1.1966.21.1.1.0.34 - mcrSfpHighRxPowerAlarm
1.3.6.1.4.1.1966.21.1.1.0.93 - mcrSfpHighRxPowerAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.94 - mcrSfpHighRxPowerWarn
1.3.6.1.4.1.1966.21.1.1.0.91 - mcrSfpHighRxPowerWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.92 - mcrSfpHighTempAlarm
1.3.6.1.4.1.1966.21.1.1.0.61 - mcrSfpHighTempAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.62 - mcrSfpHighTempWarn
1.3.6.1.4.1.1966.21.1.1.0.59 - mcrSfpHighTempWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.60 - mcrSfpHighTxBiasAlarm
1.3.6.1.4.1.1966.21.1.1.0.77 - mcrSfpHighTxBiasAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.78 - mcrSfpHighTxBiasWarn
1.3.6.1.4.1.1966.21.1.1.0.75 - mcrSfpHighTxBiasWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.76 - mcrSfpHighTxPowerAlarm
1.3.6.1.4.1.1966.21.1.1.0.85 - mcrSfpHighTxPowerAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.86 - mcrSfpHighTxPowerWarn
1.3.6.1.4.1.1966.21.1.1.0.83 - mcrSfpHighTxPowerWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.84 - mcrSfpHighVoltAlarm
1.3.6.1.4.1.1966.21.1.1.0.69 - mcrSfpHighVoltAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.70 - mcrSfpHighVoltWarn
1.3.6.1.4.1.1966.21.1.1.0.67 - mcrSfpHighVoltWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.68 - mcrSfpInserted
1.3.6.1.4.1.1966.21.1.1.0.57 - mcrSfpLostComm
1.3.6.1.4.1.1966.21.1.1.0.103 - mcrSfpLowRxPowerAlarm
1.3.6.1.4.1.1966.21.1.1.0.97 - mcrSfpLowRxPowerAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.98 - mcrSfpLowRxPowerWarn
1.3.6.1.4.1.1966.21.1.1.0.95 - mcrSfpLowRxPowerWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.96 - mcrSfpLowTempAlarm
1.3.6.1.4.1.1966.21.1.1.0.65 - mcrSfpLowTempAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.66 - mcrSfpLowTempWarn
1.3.6.1.4.1.1966.21.1.1.0.63 - mcrSfpLowTempWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.64 - mcrSfpLowTxBiasAlarm
1.3.6.1.4.1.1966.21.1.1.0.81 - mcrSfpLowTxBiasAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.82 - mcrSfpLowTxBiasWarn
1.3.6.1.4.1.1966.21.1.1.0.79 - mcrSfpLowTxBiasWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.80 - mcrSfpLowTxPowerAlarm
1.3.6.1.4.1.1966.21.1.1.0.89 - mcrSfpLowTxPowerAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.90 - mcrSfpLowTxPowerWarn
1.3.6.1.4.1.1966.21.1.1.0.87 - mcrSfpLowTxPowerWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.88 - mcrSfpLowVoltAlarm
1.3.6.1.4.1.1966.21.1.1.0.73 - mcrSfpLowVoltAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.74 - mcrSfpLowVoltWarn
1.3.6.1.4.1.1966.21.1.1.0.71 - mcrSfpLowVoltWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.72 - mcrSfpPortShutdown
1.3.6.1.4.1.1966.21.1.1.0.107 - mcrSfpPortShutdownRecov
1.3.6.1.4.1.1966.21.1.1.0.108 - mcrSfpRecovComm
1.3.6.1.4.1.1966.21.1.1.0.104 - mcrSfpRemoved
1.3.6.1.4.1.1966.21.1.1.0.58 - mcrSfpSpeedMismatch
1.3.6.1.4.1.1966.21.1.1.0.237 - mcrSfpSpeedMismatchRecov
1.3.6.1.4.1.1966.21.1.1.0.238 - mcrXfpHigh18VCurrentAlarm
1.3.6.1.4.1.1966.21.1.1.0.191 - mcrXfpHigh18VCurrentAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.192 - mcrXfpHigh18VCurrentWarn
1.3.6.1.4.1.1966.21.1.1.0.189 - mcrXfpHigh18VCurrentWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.190 - mcrXfpHigh18VoltAlarm
1.3.6.1.4.1.1966.21.1.1.0.159 - mcrXfpHigh18VoltAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.160 - mcrXfpHigh18VoltWarn
1.3.6.1.4.1.1966.21.1.1.0.157 - mcrXfpHigh18VoltWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.158 - mcrXfpHigh33VCurrentAlarm
1.3.6.1.4.1.1966.21.1.1.0.183 - mcrXfpHigh33VCurrentAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.184 - mcrXfpHigh33VCurrentWarn
1.3.6.1.4.1.1966.21.1.1.0.181 - mcrXfpHigh33VCurrentWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.182 - mcrXfpHigh33VoltAlarm
1.3.6.1.4.1.1966.21.1.1.0.151 - mcrXfpHigh33VoltAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.152 - mcrXfpHigh33VoltWarn
1.3.6.1.4.1.1966.21.1.1.0.149 - mcrXfpHigh33VoltWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.150 - mcrXfpHigh5VCurrentAlarm
1.3.6.1.4.1.1966.21.1.1.0.175 - mcrXfpHigh5VCurrentAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.176 - mcrXfpHigh5VCurrentWarn
1.3.6.1.4.1.1966.21.1.1.0.173 - mcrXfpHigh5VCurrentWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.174 - mcrXfpHigh5VoltAlarm
1.3.6.1.4.1.1966.21.1.1.0.143 - mcrXfpHigh5VoltAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.144 - mcrXfpHigh5VoltWarn
1.3.6.1.4.1.1966.21.1.1.0.141 - mcrXfpHigh5VoltWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.142 - mcrXfpHighApdBiasAlarm
1.3.6.1.4.1.1966.21.1.1.0.111 - mcrXfpHighApdBiasAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.112 - mcrXfpHighApdBiasWarn
1.3.6.1.4.1.1966.21.1.1.0.109 - mcrXfpHighApdBiasWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.110 - mcrXfpHighLaserTempAlarm
1.3.6.1.4.1.1966.21.1.1.0.127 - mcrXfpHighLaserTempAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.128 - mcrXfpHighLaserTempWarn
1.3.6.1.4.1.1966.21.1.1.0.125 - mcrXfpHighLaserTempWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.126 - mcrXfpHighLaserWavelengthAlarm
1.3.6.1.4.1.1966.21.1.1.0.135 - mcrXfpHighLaserWavelengthAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.136 - mcrXfpHighLaserWavelengthWarn
1.3.6.1.4.1.1966.21.1.1.0.133 - mcrXfpHighLaserWavelengthWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.134 - mcrXfpHighM52VCurrentAlarm
1.3.6.1.4.1.1966.21.1.1.0.199 - mcrXfpHighM52VCurrentAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.200 - mcrXfpHighM52VCurrentWarn
1.3.6.1.4.1.1966.21.1.1.0.197 - mcrXfpHighM52VCurrentWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.198 - mcrXfpHighM52VoltAlarm
1.3.6.1.4.1.1966.21.1.1.0.167 - mcrXfpHighM52VoltAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.168 - mcrXfpHighM52VoltWarn
1.3.6.1.4.1.1966.21.1.1.0.165 - mcrXfpHighM52VoltWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.166 - mcrXfpHighTecCurrentAlarm
1.3.6.1.4.1.1966.21.1.1.0.119 - mcrXfpHighTecCurrentAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.120 - mcrXfpHighTecCurrentWarn
1.3.6.1.4.1.1966.21.1.1.0.117 - mcrXfpHighTecCurrentWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.118 - mcrXfpHighVCC2Alarm
1.3.6.1.4.1.1966.21.1.1.0.223 - mcrXfpHighVCC2AlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.224 - mcrXfpHighVCC2Warn
1.3.6.1.4.1.1966.21.1.1.0.221 - mcrXfpHighVCC2WarnRecov
1.3.6.1.4.1.1966.21.1.1.0.222 - mcrXfpHighVCC3Alarm
1.3.6.1.4.1.1966.21.1.1.0.215 - mcrXfpHighVCC3AlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.216 - mcrXfpHighVCC3Warn
1.3.6.1.4.1.1966.21.1.1.0.213 - mcrXfpHighVCC3WarnRecov
1.3.6.1.4.1.1966.21.1.1.0.214 - mcrXfpHighVCC5Alarm
1.3.6.1.4.1.1966.21.1.1.0.207 - mcrXfpHighVCC5AlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.208 - mcrXfpHighVCC5Warn
1.3.6.1.4.1.1966.21.1.1.0.205 - mcrXfpHighVCC5WarnRecov
1.3.6.1.4.1.1966.21.1.1.0.206 - mcrXfpHighVEE5Alarm
1.3.6.1.4.1.1966.21.1.1.0.231 - mcrXfpHighVEE5AlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.232 - mcrXfpHighVEE5Warn
1.3.6.1.4.1.1966.21.1.1.0.229 - mcrXfpHighVEE5WarnRecov
1.3.6.1.4.1.1966.21.1.1.0.230 - mcrXfpLow18VCurrentAlarm
1.3.6.1.4.1.1966.21.1.1.0.195 - mcrXfpLow18VCurrentAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.196 - mcrXfpLow18VCurrentWarn
1.3.6.1.4.1.1966.21.1.1.0.193 - mcrXfpLow18VCurrentWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.194 - mcrXfpLow18VoltAlarm
1.3.6.1.4.1.1966.21.1.1.0.163 - mcrXfpLow18VoltAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.164 - mcrXfpLow18VoltWarn
1.3.6.1.4.1.1966.21.1.1.0.161 - mcrXfpLow18VoltWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.162 - mcrXfpLow33VCurrentAlarm
1.3.6.1.4.1.1966.21.1.1.0.187 - mcrXfpLow33VCurrentAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.188 - mcrXfpLow33VCurrentWarn
1.3.6.1.4.1.1966.21.1.1.0.185 - mcrXfpLow33VCurrentWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.186 - mcrXfpLow33VoltAlarm
1.3.6.1.4.1.1966.21.1.1.0.155 - mcrXfpLow33VoltAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.156 - mcrXfpLow33VoltWarn
1.3.6.1.4.1.1966.21.1.1.0.153 - mcrXfpLow33VoltWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.154 - mcrXfpLow5VCurrentAlarm
1.3.6.1.4.1.1966.21.1.1.0.179 - mcrXfpLow5VCurrentAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.180 - mcrXfpLow5VCurrentWarn
1.3.6.1.4.1.1966.21.1.1.0.177 - mcrXfpLow5VCurrentWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.178 - mcrXfpLow5VoltAlarm
1.3.6.1.4.1.1966.21.1.1.0.147 - mcrXfpLow5VoltAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.148 - mcrXfpLow5VoltWarn
1.3.6.1.4.1.1966.21.1.1.0.145 - mcrXfpLow5VoltWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.146 - mcrXfpLowApdBiasAlarm
1.3.6.1.4.1.1966.21.1.1.0.115 - mcrXfpLowApdBiasAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.116 - mcrXfpLowApdBiasWarn
1.3.6.1.4.1.1966.21.1.1.0.113 - mcrXfpLowApdBiasWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.114 - mcrXfpLowLaserTempAlarm
1.3.6.1.4.1.1966.21.1.1.0.131 - mcrXfpLowLaserTempAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.132 - mcrXfpLowLaserTempWarn
1.3.6.1.4.1.1966.21.1.1.0.129 - mcrXfpLowLaserTempWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.130 - mcrXfpLowLaserWavelengthAlarm
1.3.6.1.4.1.1966.21.1.1.0.139 - mcrXfpLowLaserWavelengthAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.140 - mcrXfpLowLaserWavelengthWarn
1.3.6.1.4.1.1966.21.1.1.0.137 - mcrXfpLowLaserWavelengthWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.138 - mcrXfpLowM52VCurrentAlarm
1.3.6.1.4.1.1966.21.1.1.0.203 - mcrXfpLowM52VCurrentAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.204 - mcrXfpLowM52VCurrentWarn
1.3.6.1.4.1.1966.21.1.1.0.201 - mcrXfpLowM52VCurrentWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.202 - mcrXfpLowM52VoltAlarm
1.3.6.1.4.1.1966.21.1.1.0.171 - mcrXfpLowM52VoltAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.172 - mcrXfpLowM52VoltWarn
1.3.6.1.4.1.1966.21.1.1.0.169 - mcrXfpLowM52VoltWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.170 - mcrXfpLowTecCurrentAlarm
1.3.6.1.4.1.1966.21.1.1.0.123 - mcrXfpLowTecCurrentAlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.124 - mcrXfpLowTecCurrentWarn
1.3.6.1.4.1.1966.21.1.1.0.121 - mcrXfpLowTecCurrentWarnRecov
1.3.6.1.4.1.1966.21.1.1.0.122 - mcrXfpLowVCC2Alarm
1.3.6.1.4.1.1966.21.1.1.0.227 - mcrXfpLowVCC2AlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.228 - mcrXfpLowVCC2Warn
1.3.6.1.4.1.1966.21.1.1.0.225 - mcrXfpLowVCC2WarnRecov
1.3.6.1.4.1.1966.21.1.1.0.226 - mcrXfpLowVCC3Alarm
1.3.6.1.4.1.1966.21.1.1.0.219 - mcrXfpLowVCC3AlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.220 - mcrXfpLowVCC3Warn
1.3.6.1.4.1.1966.21.1.1.0.217 - mcrXfpLowVCC3WarnRecov
1.3.6.1.4.1.1966.21.1.1.0.218 - mcrXfpLowVCC5Alarm
1.3.6.1.4.1.1966.21.1.1.0.211 - mcrXfpLowVCC5AlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.212 - mcrXfpLowVCC5Warn
1.3.6.1.4.1.1966.21.1.1.0.209 - mcrXfpLowVCC5WarnRecov
1.3.6.1.4.1.1966.21.1.1.0.210 - mcrXfpLowVEE5Alarm
1.3.6.1.4.1.1966.21.1.1.0.235 - mcrXfpLowVEE5AlarmRecov
1.3.6.1.4.1.1966.21.1.1.0.236 - mcrXfpLowVEE5Warn
1.3.6.1.4.1.1966.21.1.1.0.233 - mcrXfpLowVEE5WarnRecov
1.3.6.1.4.1.1966.21.1.1.0.234 - mcrXfpPowerExceeded
1.3.6.1.4.1.1966.21.1.1.0.239 - mcrXfpPowerExceededRecov
1.3.6.1.4.1.1966.21.1.1.0.240