PANDUIT-MIB
Panduit Corp.Panduit iPDU
snmptranslate -m PANDUIT-MIB -Tpsnmpwalk -v2c -c <community> -m PANDUIT-MIB <host> 1.3.6.1.4.1.19536.10Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
|---|---|
| SNMPv2-MIB | sysDescr |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Npanduit | 1.3.6.1.4.1.19536 | ||||||||||||||||||||
| Ig5 | 1.3.6.1.4.1.19536.10 | ||||||||||||||||||||
identity Panduit iPDU | |||||||||||||||||||||
| Npdug5 | 1.3.6.1.4.1.19536.10.1 | ||||||||||||||||||||
| Npdug5Ident | 1.3.6.1.4.1.19536.10.1.1 | ||||||||||||||||||||
| Spdug5NumberPDU | 1.3.6.1.4.1.19536.10.1.1.1 | Integer32 (1..4) | RO | ||||||||||||||||||
scalar · Integer32 (1..4) · read-only · current The number of PDUs detected (in its daisy chain). | |||||||||||||||||||||
| Tpdug5IdentTable | 1.3.6.1.4.1.19536.10.1.1.2 | NA | |||||||||||||||||||
table · not-accessible · current Aggregate Object with number of entries equal to pdug5NumberPDU . | |||||||||||||||||||||
| Rpdug5IdentEntry | 1.3.6.1.4.1.19536.10.1.1.2.1 | NA | |||||||||||||||||||
row · not-accessible · current The Identity table entry containing the name, model, manufacturer, firmware version, part number, etc.
| |||||||||||||||||||||
| Cpdug5IdentIndex | 1.3.6.1.4.1.19536.10.1.1.2.1.1 | Integer32 (1..6) | NA | ||||||||||||||||||
column · Integer32 (1..6) · not-accessible · current Index for the pdug5IdentEntry table. | |||||||||||||||||||||
| Cpdug5Name | 1.3.6.1.4.1.19536.10.1.1.2.1.2 | DisplayString (SIZE (0..63)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-write · current The string identify the device in daisy chain. Example PDU A. | |||||||||||||||||||||
| Cpdug5Model | 1.3.6.1.4.1.19536.10.1.1.2.1.3 | DisplayString (SIZE (0..63)) | RO | 346-415V, 32A, 22.0kVA, 50/60Hz | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · current The Device Model. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5Manufacturer | 1.3.6.1.4.1.19536.10.1.1.2.1.4 | DisplayString (SIZE (0..63)) | RO | PANDUIT | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · current The Device Manufacturer Name. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5FirmwareVersion | 1.3.6.1.4.1.19536.10.1.1.2.1.5 | DisplayString (SIZE (0..63)) | RO | 2.3.21 | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · current The firmware revision level of the device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5FirmwareVersionTimeStamp | 1.3.6.1.4.1.19536.10.1.1.2.1.6 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current Timestamp of when the PDU firmware was last updated | |||||||||||||||||||||
| Cpdug5PartNumber | 1.3.6.1.4.1.19536.10.1.1.2.1.7 | DisplayString (SIZE (0..63)) | RO | P42D04M | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · current The device part number. Example P36E09M. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5SerialNumber | 1.3.6.1.4.1.19536.10.1.1.2.1.8 | DisplayString (SIZE (0..63)) | RO | CN187D6053 | |||||||||||||||||
| Cpdug5Status | 1.3.6.1.4.1.19536.10.1.1.2.1.9 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The overall status of the device. A value of OK(2) indicates the device is operating normally. A value of degraded(3) indicates the device is operating with warning indicators. A value of failed(4) indicates the device is operating with critical indicators.
| |||||||||||||||||||||
| Cpdug5Controllable | 1.3.6.1.4.1.19536.10.1.1.2.1.10 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object indicates whether or not the device is controllable.
| |||||||||||||||||||||
| Cpdug5InputPhaseCount | 1.3.6.1.4.1.19536.10.1.1.2.1.11 | Integer32 (1..3) | RO | ||||||||||||||||||
column · Integer32 (1..3) · read-only · current The number of input phase on this pdu 1 or 3. | |||||||||||||||||||||
| Cpdug5GroupCount | 1.3.6.1.4.1.19536.10.1.1.2.1.12 | Integer32 (0..12) | RO | ||||||||||||||||||
column · Integer32 (0..12) · read-only · current The number of groups (breakers) on this pdu. | |||||||||||||||||||||
| Cpdug5OutletCount | 1.3.6.1.4.1.19536.10.1.1.2.1.13 | Integer32 (1..48) | RO | ||||||||||||||||||
column · Integer32 (1..48) · read-only · current The number of outlets in this PDU. | |||||||||||||||||||||
| Cpdug5MACAddress | 1.3.6.1.4.1.19536.10.1.1.2.1.14 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The assigned MAC address for this PDU. | |||||||||||||||||||||
| Cpdug5IPv4Address | 1.3.6.1.4.1.19536.10.1.1.2.1.15 | IpAddress | RO | ||||||||||||||||||
column · IpAddress · read-only · current The current IPv4 Address. A value of 0.0.0.0 indicates an error or an unset option. | |||||||||||||||||||||
| Cpdug5IPv6Address | 1.3.6.1.4.1.19536.10.1.1.2.1.16 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The current IPv6 Address. A value of 0.0.0.0.0.0 indicates an error or an unset option. | |||||||||||||||||||||
| Cpdug5HWVersion | 1.3.6.1.4.1.19536.10.1.1.2.1.17 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The current Hardware Version. 1.0 - G5 (STM) No Powershare, 1.5 - G5 (STM) with Powershare, 2.0 - G6 Processor | |||||||||||||||||||||
| Tpdug5ConfigTable | 1.3.6.1.4.1.19536.10.1.1.3 | NA | |||||||||||||||||||
table · not-accessible · current Aggregate Object with number of entries equal to pdug5NumberPDU. | |||||||||||||||||||||
| Rpdug5ConfigEntry | 1.3.6.1.4.1.19536.10.1.1.3.1 | NA | |||||||||||||||||||
row · not-accessible · current Read Configuration data from the PDU being queried.
| |||||||||||||||||||||
| Cpdug5ConfigIndex | 1.3.6.1.4.1.19536.10.1.1.3.1.1 | Integer32 (1..4) | NA | ||||||||||||||||||
column · Integer32 (1..4) · not-accessible · current The index of PDU configuration entry. | |||||||||||||||||||||
| Cpdug5ConfigSsh | 1.3.6.1.4.1.19536.10.1.1.3.1.2 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Setting this OID to off(0) will disable the SSH connection. Setting this OID to on(1) will enable the SSH connection. iNC reboot will be required for the settings to take effect.
| |||||||||||||||||||||
| Cpdug5ConfigFtps | 1.3.6.1.4.1.19536.10.1.1.3.1.3 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Setting this OID to off(0) will disable the FTPS connection. Setting this OID to on(1) will enable the FTPS connection. iNC reboot will be required for the settings to take effect
| |||||||||||||||||||||
| Cpdug5ConfigHttp | 1.3.6.1.4.1.19536.10.1.1.3.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Setting this OID to off(0) will disable the HTTP connection. Setting this OID to on(1) will enable the HTTP connection.iNC reboot will be required for the settings to take effect
| |||||||||||||||||||||
| Cpdug5ConfigHttps | 1.3.6.1.4.1.19536.10.1.1.3.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Setting this OID to off(0) will disable the HTTPS connection. Setting this OID to on(1) will enable the HTTPS connection.iNC reboot will be required for the settings to take effect
| |||||||||||||||||||||
| Cpdug5ConfigIPv4IPv6Switch | 1.3.6.1.4.1.19536.10.1.1.3.1.6 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Setting this OID to IPv4(1) will enable the IPv4 configuration. Setting this OID to IPv6(2) will enable the IPv6 configuration. Setting this OID to IPv4&IPv6(3) will enable both IPv4 and IPv6 configuration.iNC reboot will be required for the settings to take effect
| |||||||||||||||||||||
| Cpdug5ConfigRedfishAPI | 1.3.6.1.4.1.19536.10.1.1.3.1.7 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Setting this OID to off(0) will disable the Redfish API. Setting this OID to on(1) will enable the Redfish API.iNC reboot will be required for the settings to take effect
| |||||||||||||||||||||
| Cpdug5ConfigOledDispalyOrientation | 1.3.6.1.4.1.19536.10.1.1.3.1.8 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Indicates the intended physical orientation of OLED display. displayNormal(1) indicates normal orientation. displayReverse(2) indicates upside down orientation.
| |||||||||||||||||||||
| Cpdug5ConfigEnergyReset | 1.3.6.1.4.1.19536.10.1.1.3.1.9 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Setting this OID to reset(2) will cause the device energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not supported this feature will respond to this OID with a value of notSupported(3). Attempts to set this OID in these models will fail.
| |||||||||||||||||||||
| Cpdug5ConfigNetworkManagementCardReset | 1.3.6.1.4.1.19536.10.1.1.3.1.10 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Getting this OID will return noOperation(0). Getting this OID to reset(1) will reset iNC.
| |||||||||||||||||||||
| Cpdug5ConfigDaisyChainStatus | 1.3.6.1.4.1.19536.10.1.1.3.1.11 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Setting this OID will change daisychain mode. 0:QNA,1:DNA.
| |||||||||||||||||||||
| Cpdug5ConfigTelnet | 1.3.6.1.4.1.19536.10.1.1.3.1.12 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Setting this OID to off(0) will disable the Telnet connection. Setting this OID to on(1) will enable the Telnet connection. iNC reboot will be required for the settings to take effect.
| |||||||||||||||||||||
| Tpdug5PowershareTable | 1.3.6.1.4.1.19536.10.1.1.4 | NA | |||||||||||||||||||
table · not-accessible · current Aggregate Object with number of entries equal to number of PDUs and Power share | |||||||||||||||||||||
| Rpdug5PowershareEntry | 1.3.6.1.4.1.19536.10.1.1.4.1 | NA | |||||||||||||||||||
row · not-accessible · current The Power share entry containing the available, input, output etc.
| |||||||||||||||||||||
| Cpdug5PowershareIndex | 1.3.6.1.4.1.19536.10.1.1.4.1.1 | Integer32 (1..4) | NA | ||||||||||||||||||
column · Integer32 (1..4) · not-accessible · current The index of the PDU Power share table entry | |||||||||||||||||||||
| Cpdug5PowershareFunctionStatus | 1.3.6.1.4.1.19536.10.1.1.4.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Power share function status on PDU.
| |||||||||||||||||||||
| Cpdug5PowershareFunctionUpstreamStatus | 1.3.6.1.4.1.19536.10.1.1.4.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Power share function status on upstream PDU
| |||||||||||||||||||||
| Cpdug5PowershareOutput | 1.3.6.1.4.1.19536.10.1.1.4.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Power share output status.
| |||||||||||||||||||||
| Cpdug5PowershareInput | 1.3.6.1.4.1.19536.10.1.1.4.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Power share input status.
| |||||||||||||||||||||
| Cpdug5PowershareOptMode | 1.3.6.1.4.1.19536.10.1.1.4.1.6 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Power share operation status of PDU. 0 meaning pdu is using powershare to power the NMC, 1 meaning pdu is using mains power to power the NMC
| |||||||||||||||||||||
| Cpdug5PowershareFunc | 1.3.6.1.4.1.19536.10.1.1.4.1.7 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Enable/Disable Powershare function of PDU. Set 1 to enable powershare. Set 0 to disable powershare
| |||||||||||||||||||||
| Npdug5Input | 1.3.6.1.4.1.19536.10.1.2 | ||||||||||||||||||||
| Tpdug5InputTable | 1.3.6.1.4.1.19536.10.1.2.1 | NA | |||||||||||||||||||
table · not-accessible · current Aggregate Object with number of entries equal to pdug5NumberPDU . | |||||||||||||||||||||
| Rpdug5InputEntry | 1.3.6.1.4.1.19536.10.1.2.1.1 | NA | |||||||||||||||||||
row · not-accessible · current The ident table entry containing the VA, Watts, WH, etc.
| |||||||||||||||||||||
| Cpdug5InputType | 1.3.6.1.4.1.19536.10.1.2.1.1.1 | INTEGER | RO | threePhaseWye(4) | |||||||||||||||||
column · INTEGER · read-only · current Type of input - single phase, split phase, three phase delta, or three phase wye.
| |||||||||||||||||||||
| Cpdug5InputFrequency | 1.3.6.1.4.1.19536.10.1.2.1.1.2 | Integer32 (0..2147483647) | RO | 500 | |||||||||||||||||
column · Integer32 (0..2147483647) · read-only · current The measured input frequency from the PDU meters in tenths of Hz. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5InputFrequencyStatus | 1.3.6.1.4.1.19536.10.1.2.1.1.3 | INTEGER | RO | good(1) | |||||||||||||||||
column · INTEGER · read-only · current Status of the measured input frequency relative to the nominal frequency and the admitted tolerance.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5InputPowerVA | 1.3.6.1.4.1.19536.10.1.2.1.1.4 | Integer32 | RO | 1022 | |||||||||||||||||
| Cpdug5InputPowerWatts | 1.3.6.1.4.1.19536.10.1.2.1.1.5 | Integer32 | RO | 956 | |||||||||||||||||
| Cpdug5InputTotalEnergy | 1.3.6.1.4.1.19536.10.1.2.1.1.6 | Integer32 | RO | 7405 | |||||||||||||||||
column · Integer32 · read-only · current A total input Watt-Hour value for all phases. Units are KWh. This value is accumulated since PDU in service. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPowerWattHourTimer | 1.3.6.1.4.1.19536.10.1.2.1.1.7 | DisplayString (SIZE (0..22)) | RO | 2018/07/16 16:26
3A 30 30 00 | |||||||||||||||||
| Cpdug5InputResettableEnergy | 1.3.6.1.4.1.19536.10.1.2.1.1.8 | Integer32 | RO | 7405276 | |||||||||||||||||
column · Integer32 · read-only · current A total input Watt-Hour value for all phases. Units are Wh. This value can be reset to 0 using GUI. In that case, the pdug5InputPowerWattHourTimer will be reset as well A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPowerFactor | 1.3.6.1.4.1.19536.10.1.2.1.1.9 | Integer32 | RO | 93 | |||||||||||||||||
column · Integer32 · read-only · current An input PF value. Units are in hundredths, for example a power factor of 0.95 would be returned as 95, and 0.92 would be returned as 92. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPowerVAR | 1.3.6.1.4.1.19536.10.1.2.1.1.10 | Integer32 | RO | 331 | |||||||||||||||||
| Cpdug5InputTotalCurrent | 1.3.6.1.4.1.19536.10.1.2.1.1.11 | Integer32 | RO | 448 | |||||||||||||||||
| Tpdug5InputPhaseTable | 1.3.6.1.4.1.19536.10.1.2.2 | NA | |||||||||||||||||||
table · not-accessible · current Aggregate Object with number of entries equal to number of PDUs (pdug5NumberPDU) and number of input phase (pdug5InputPhaseCount). | |||||||||||||||||||||
| Rpdug5InputPhaseEntry | 1.3.6.1.4.1.19536.10.1.2.2.1 | NA | |||||||||||||||||||
row · not-accessible · current The input table entry containing the voltage, current, frequency, power for each phase. Entries are given with number of pdu and number of input phase 1, 2, or 3. | |||||||||||||||||||||
| Cpdug5InputPhaseIndex | 1.3.6.1.4.1.19536.10.1.2.2.1.1 | Integer32 (1..3) | NA | ||||||||||||||||||
column · Integer32 (1..3) · not-accessible · current Index for the pdug5InputEntry table. | |||||||||||||||||||||
| Cpdug5InputPhaseVoltageMeasType | 1.3.6.1.4.1.19536.10.1.2.2.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Value indicates what input voltage is being measured in this table row - single phase voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2, phase 2 to phase 3, or phase 3 to phase 1.
| |||||||||||||||||||||
| Cpdug5InputPhaseVoltage | 1.3.6.1.4.1.19536.10.1.2.2.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current An input voltage measurement value. Values is in 0.1 V. | |||||||||||||||||||||
| Cpdug5InputPhaseVoltageThStatus | 1.3.6.1.4.1.19536.10.1.2.2.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Status of the measured input voltage relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdug5InputPhaseVoltageThLowerWarning | 1.3.6.1.4.1.19536.10.1.2.2.1.5 | Integer32 (-1..500000) | RW | ||||||||||||||||||
column · Integer32 (-1..500000) · read-write · current Lower warning threshold. Units are 0.1 volts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhaseVoltageThLowerCritical | 1.3.6.1.4.1.19536.10.1.2.2.1.6 | Integer32 (-1..500000) | RW | ||||||||||||||||||
column · Integer32 (-1..500000) · read-write · current Lower critical threshold. Units are 0.1 volts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhaseVoltageThUpperWarning | 1.3.6.1.4.1.19536.10.1.2.2.1.7 | Integer32 (-1..500000) | RW | ||||||||||||||||||
column · Integer32 (-1..500000) · read-write · current Upper warning threshold. Units are 0.1 volts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhaseVoltageThUpperCritical | 1.3.6.1.4.1.19536.10.1.2.2.1.8 | Integer32 (-1..500000) | RW | ||||||||||||||||||
column · Integer32 (-1..500000) · read-write · current Upper critical threshold. Units are 0.1 volts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhaseCurrentMeasType | 1.3.6.1.4.1.19536.10.1.2.2.1.9 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Which input wire is being measured in this table row - single phase, neutral, phase 1, phase 2, or phase 3.
| |||||||||||||||||||||
| Cpdug5InputPhaseCurrentRating | 1.3.6.1.4.1.19536.10.1.2.2.1.10 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Rated current capacity of the input. A negative value indicates that the hardware current capacity is unknown. Units are 0.01 amps. | |||||||||||||||||||||
| Cpdug5InputPhaseCurrent | 1.3.6.1.4.1.19536.10.1.2.2.1.11 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current An input current measurement value. Units are 0.01 amps. | |||||||||||||||||||||
| Cpdug5InputPhaseCurrentThStatus | 1.3.6.1.4.1.19536.10.1.2.2.1.12 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Status of the measured input current relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdug5InputPhaseCurrentThLowerWarning | 1.3.6.1.4.1.19536.10.1.2.2.1.13 | Integer32 (-1..100000) | RW | ||||||||||||||||||
column · Integer32 (-1..100000) · read-write · current Lower warning threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhaseCurrentThLowerCritical | 1.3.6.1.4.1.19536.10.1.2.2.1.14 | Integer32 (-1..100000) | RW | ||||||||||||||||||
column · Integer32 (-1..100000) · read-write · current Lower critical threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhaseCurrentThUpperWarning | 1.3.6.1.4.1.19536.10.1.2.2.1.15 | Integer32 (-1..100000) | RW | ||||||||||||||||||
column · Integer32 (-1..100000) · read-write · current Upper warning threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhaseCurrentThUpperCritical | 1.3.6.1.4.1.19536.10.1.2.2.1.16 | Integer32 (-1..100000) | RW | ||||||||||||||||||
column · Integer32 (-1..100000) · read-write · current Upper critical threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhaseCurrentPercentLoad | 1.3.6.1.4.1.19536.10.1.2.2.1.17 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Current percent load, based on the rated current capacity. Units are percentage, for example 80% will be returned as 80. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhasePowerMeasType | 1.3.6.1.4.1.19536.10.1.2.2.1.18 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Which input wire is being measured in this table row - single phase, neutral, phase 1, phase 2, or phase 3.
| |||||||||||||||||||||
| Cpdug5InputPhasePowerVA | 1.3.6.1.4.1.19536.10.1.2.2.1.19 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current An input VA value. Units are VA. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhasePowerWatts | 1.3.6.1.4.1.19536.10.1.2.2.1.20 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current An input Watts value. Units are Watts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhasePowerWattHour | 1.3.6.1.4.1.19536.10.1.2.2.1.21 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current A Watt-Hour value for each Input phase. Units are WH. This value can be reset to 0 using GUI. In that case, the pdug5InputPhasePowerWattHourTimer will be reset as well A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhasePowerWattHourTimer | 1.3.6.1.4.1.19536.10.1.2.2.1.22 | DisplayString (SIZE (0..22)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..22)) · read-only · current Timestamp of when input Watt-hours (inputWh) was last reset. | |||||||||||||||||||||
| Cpdug5InputPhasePowerFactor | 1.3.6.1.4.1.19536.10.1.2.2.1.23 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current An input PF value. Units are in hundredths, for example a power factor of 0.95 would be returned as 95, and 0.92 would be returned as 92. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhasePowerVAR | 1.3.6.1.4.1.19536.10.1.2.2.1.24 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current An input VAR value. Units are VAR. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPhaseVoltageThResetThld | 1.3.6.1.4.1.19536.10.1.2.2.1.25 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The Reset threshold is the number of volts the reading needs to fall below the threshold setting for the condition to be cleared. Units are 0.1 volts. | |||||||||||||||||||||
| Cpdug5InputPhaseVoltageThChangeDelay | 1.3.6.1.4.1.19536.10.1.2.2.1.26 | Integer32 (0..100) | RW | ||||||||||||||||||
column · Integer32 (0..100) · read-write · current The number of consecutive sample that the condition is present before an alarm is raised. | |||||||||||||||||||||
| Cpdug5InputPhaseVoltageThCtrl | 1.3.6.1.4.1.19536.10.1.2.2.1.27 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Input phase voltage alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | |||||||||||||||||||||
| Cpdug5InputPhaseCurrentThResetThld | 1.3.6.1.4.1.19536.10.1.2.2.1.28 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The Reset threshold is the number of amps the reading needs to fall below the threshold setting for the condition to be cleared. Units are 0.01 amps. | |||||||||||||||||||||
| Cpdug5InputPhaseCurrentThChangeDelay | 1.3.6.1.4.1.19536.10.1.2.2.1.29 | Integer32 (0..100) | RW | ||||||||||||||||||
column · Integer32 (0..100) · read-write · current The number of consecutive sample that the condition is present before an alarm is raised. | |||||||||||||||||||||
| Cpdug5InputPhaseCurrentThCtrl | 1.3.6.1.4.1.19536.10.1.2.2.1.30 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Input phase current alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | |||||||||||||||||||||
| Cpdug5InputPowerThresholdThLowerWarning | 1.3.6.1.4.1.19536.10.1.2.2.1.31 | Integer32 (-1..500000) | RW | ||||||||||||||||||
column · Integer32 (-1..500000) · read-write · current Lower warning Power threshold. Units are in Watts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPowerThresholdThLowerCritical | 1.3.6.1.4.1.19536.10.1.2.2.1.32 | Integer32 (-1..500000) | RW | ||||||||||||||||||
column · Integer32 (-1..500000) · read-write · current Lower critical Power threshold. Units are in Watts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPowerThresholdThUpperWarning | 1.3.6.1.4.1.19536.10.1.2.2.1.33 | Integer32 (-1..500000) | RW | ||||||||||||||||||
column · Integer32 (-1..500000) · read-write · current Upper warning Power threshold. Units are in Watts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPowerThresholdThUpperCritical | 1.3.6.1.4.1.19536.10.1.2.2.1.34 | Integer32 (-1..500000) | RW | ||||||||||||||||||
column · Integer32 (-1..500000) · read-write · current Upper critical Power threshold. Units are in Watts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputPowerThresholdThResetThld | 1.3.6.1.4.1.19536.10.1.2.2.1.35 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The Reset threshold is the number of watts the reading needs to fall below the threshold setting for the condition to be cleared. Units are watts. | |||||||||||||||||||||
| Cpdug5InputPowerThresholdThChangeDelay | 1.3.6.1.4.1.19536.10.1.2.2.1.36 | Integer32 (0..100) | RW | ||||||||||||||||||
column · Integer32 (0..100) · read-write · current The number of consecutive sample that the condition is present before an alarm is raised. | |||||||||||||||||||||
| Cpdug5InputPowerThresholdThCtrl | 1.3.6.1.4.1.19536.10.1.2.2.1.37 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Power alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | |||||||||||||||||||||
| Cpdug5InputEnergyThresholdThUpperWarning | 1.3.6.1.4.1.19536.10.1.2.2.1.38 | Integer32 (-1..500000) | RW | ||||||||||||||||||
column · Integer32 (-1..500000) · read-write · current Upper warning Energy threshold. Units are in Watts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputEnergyThresholdThUpperCritical | 1.3.6.1.4.1.19536.10.1.2.2.1.39 | Integer32 (-1..500000) | RW | ||||||||||||||||||
column · Integer32 (-1..500000) · read-write · current Upper critical Energy threshold. Units are in Watts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputEnergyThresholdThResetThld | 1.3.6.1.4.1.19536.10.1.2.2.1.40 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The Reset threshold is the number of watts the reading needs to fall below the threshold setting for the condition to be cleared. Units are watts. | |||||||||||||||||||||
| Cpdug5InputEnergyThresholdThChangeDelay | 1.3.6.1.4.1.19536.10.1.2.2.1.41 | Integer32 (0..100) | RW | ||||||||||||||||||
column · Integer32 (0..100) · read-write · current The number of consecutive sample that the condition is present before an alarm is raised. | |||||||||||||||||||||
| Cpdug5InputEnergyThresholdThCtrl | 1.3.6.1.4.1.19536.10.1.2.2.1.42 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Energy alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | |||||||||||||||||||||
| Cpdug5InputPhasePowerThStatus | 1.3.6.1.4.1.19536.10.1.2.2.1.43 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Status of the measured input current relative to the configured thresholds.
| |||||||||||||||||||||
| Tpdug5InputRcmTable | 1.3.6.1.4.1.19536.10.1.2.3 | NA | |||||||||||||||||||
table · not-accessible · current Aggregate Object with number of entries equal to number of PDUs (pdug5NumberPDU) and number of RCM modules per PDU. | |||||||||||||||||||||
| Rpdug5InputRcmEntry | 1.3.6.1.4.1.19536.10.1.2.3.1 | NA | |||||||||||||||||||
row · not-accessible · current The ident table entry containing the RCM Module status, RCM current, RCM module threshold settings, etc.
| |||||||||||||||||||||
| Cpdug5InputRcmEnabled | 1.3.6.1.4.1.19536.10.1.2.3.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current RCM configuration value off(0) if the PDU doesn't have RCM, on(1) if the PDU has RCM.
| |||||||||||||||||||||
| Cpdug5InputRcmModStatus | 1.3.6.1.4.1.19536.10.1.2.3.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current RCM module status ok(2) if the PDU can communicate with the RCM module, failed(4) if the PDU cannot communicate with the RCM module, degraded(3) if the PDU can communicate with the RCM module and the last self-test failed.
| |||||||||||||||||||||
| Cpdug5InputRcmThUpperWarning | 1.3.6.1.4.1.19536.10.1.2.3.1.3 | Integer32 (15..300) | RW | ||||||||||||||||||
column · Integer32 (15..300) · read-write · current RCM Current Upper warning threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputRcmThUpperCritical | 1.3.6.1.4.1.19536.10.1.2.3.1.4 | Integer32 (15..300) | RW | ||||||||||||||||||
column · Integer32 (15..300) · read-write · current RCM Current Upper critical threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5InputRcmThResetThld | 1.3.6.1.4.1.19536.10.1.2.3.1.5 | Integer32 (1..16) | RW | ||||||||||||||||||
column · Integer32 (1..16) · read-write · current The Reset threshold is the number of amps the reading needs to fall below the threshold setting for the condition to be cleared. Units are 0.01 amps. | |||||||||||||||||||||
| Cpdug5InputRcmThChangeDelay | 1.3.6.1.4.1.19536.10.1.2.3.1.6 | Integer32 (0..100) | RW | ||||||||||||||||||
column · Integer32 (0..100) · read-write · current The number of consecutive sample that the condition is present before an alarm is raised. | |||||||||||||||||||||
| Cpdug5InputRcmThCtrl | 1.3.6.1.4.1.19536.10.1.2.3.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Rcm current alarm threshold control:
0 - Enable UC and UW
1 - Disable UC and Enable UW
2 - Enable UC and Disable UW
3 - Disable UC and UW
4 and above - Bad input | |||||||||||||||||||||
| Cpdug5InputRcmThStatus | 1.3.6.1.4.1.19536.10.1.2.3.1.8 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Status of the measured Rcm current relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdug5InputRcmCurrent | 1.3.6.1.4.1.19536.10.1.2.3.1.9 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Rcm module current reading. Units are milliAmps. | |||||||||||||||||||||
| Tpdug5InputRcmSelfTestTable | 1.3.6.1.4.1.19536.10.1.2.4 | NA | |||||||||||||||||||
table · not-accessible · current Aggregate Object with number of entries equal to number of PDUs (pdug5NumberPDU) and number of Rcm modules per PDU. | |||||||||||||||||||||
| Rpdug5InputRcmSelfTestEntry | 1.3.6.1.4.1.19536.10.1.2.4.1 | NA | |||||||||||||||||||
row · not-accessible · current The ident table entry containing the Rcm Module Self Test Enable, Schedule, LastRunTime,LastRunStatus etc.
| |||||||||||||||||||||
| Cpdug5InputRcmSelfTestEnable | 1.3.6.1.4.1.19536.10.1.2.4.1.1 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Rcm Self Test configuration value Disable(0) if the self test is disabled on the PDU, Enable(1) if self test is enabled on the PDU .
| |||||||||||||||||||||
| Cpdug5InputRcmSelfTestFreq | 1.3.6.1.4.1.19536.10.1.2.4.1.2 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Rcm module self test run frequency , the time for the test is set from Pdug5RcmSelfTestNextRunTime, the self test will be repeated based on the setting as Daily(1),Weekly(2),First Day Of Month(3),Yearly(4)
| |||||||||||||||||||||
| Cpdug5InputRcmSelfTestHour | 1.3.6.1.4.1.19536.10.1.2.4.1.3 | Integer32 (0..23) | RW | ||||||||||||||||||
column · Integer32 (0..23) · read-write · current Rcm module self test schedule hour setting (0 to 23 hour),-1 means feature not available | |||||||||||||||||||||
| Cpdug5InputRcmSelfTestMinute | 1.3.6.1.4.1.19536.10.1.2.4.1.4 | Integer32 (0..59) | RW | ||||||||||||||||||
column · Integer32 (0..59) · read-write · current Rcm module self test schedule minute setting (0 to 59 minute),-1 means feature not available | |||||||||||||||||||||
| Cpdug5InputRcmSelfTestDay | 1.3.6.1.4.1.19536.10.1.2.4.1.5 | Integer32 (1..31) | RW | ||||||||||||||||||
column · Integer32 (1..31) · read-write · current Rcm module self test schedule day setting - Can be 0 to 6 when pduInputRcmSelfTestFreq is weekly(2), - Can be 1 to 31 when pduInputRcmSelfTestFreq is monthly(3) or yearly(4), - (-1) means feature not available | |||||||||||||||||||||
| Cpdug5InputRcmSelfTestMonth | 1.3.6.1.4.1.19536.10.1.2.4.1.6 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Rcm module self test schedule month setting,-1 means feature not available
| |||||||||||||||||||||
| Cpdug5InputRcmSelfTestNextRunTime | 1.3.6.1.4.1.19536.10.1.2.4.1.7 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current next run date and Time for self test. | |||||||||||||||||||||
| Cpdug5InputRcmSelfTestLastRunTime | 1.3.6.1.4.1.19536.10.1.2.4.1.8 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current Date and Time when the self test run previously | |||||||||||||||||||||
| Cpdug5InputRcmSelfTestLastRunStatus | 1.3.6.1.4.1.19536.10.1.2.4.1.9 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Status of the lastest self test run
| |||||||||||||||||||||
| Cpdug5InputRcmSelfTest | 1.3.6.1.4.1.19536.10.1.2.4.1.10 | Integer32 (0..1) | RW | ||||||||||||||||||
column · Integer32 (0..1) · read-write · current Rcm module on demand self test, 1 to start the on demand self test | |||||||||||||||||||||
| Npdug5Group | 1.3.6.1.4.1.19536.10.1.3 | ||||||||||||||||||||
| Tpdug5GroupTable | 1.3.6.1.4.1.19536.10.1.3.1 | NA | |||||||||||||||||||
table · not-accessible · current Aggregate Object with number of entries equal to number of PDUs and number of breakers (pdug5GroupCount). | |||||||||||||||||||||
| Rpdug5GroupEntry | 1.3.6.1.4.1.19536.10.1.3.1.1 | NA | |||||||||||||||||||
row · not-accessible · current The input table entry containing the name, voltages, currents, power, etc. | |||||||||||||||||||||
| Cpdug5GroupIndex | 1.3.6.1.4.1.19536.10.1.3.1.1.1 | Integer32 (0..12) | NA | 1 | |||||||||||||||||
| Cpdug5GroupName | 1.3.6.1.4.1.19536.10.1.3.1.1.2 | DisplayString (SIZE (1..31)) | RW | 42:33:00 | |||||||||||||||||
| Cpdug5GroupType | 1.3.6.1.4.1.19536.10.1.3.1.1.3 | INTEGER | RO | breaker1pole(2) | |||||||||||||||||
column · INTEGER · read-only · current The type of the group. (5) has no breaker
| |||||||||||||||||||||
| Cpdug5GroupVoltageMeasType | 1.3.6.1.4.1.19536.10.1.3.1.1.4 | INTEGER | RO | phase1toN(2) | |||||||||||||||||
column · INTEGER · read-only · current Value indicates what input voltage is being measured in this table row - single phase voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2, phase 2 to phase 3, or phase 3 to phase 1.
| |||||||||||||||||||||
| Cpdug5GroupVoltage | 1.3.6.1.4.1.19536.10.1.3.1.1.5 | Integer32 | RO | 2297 | |||||||||||||||||
| Cpdug5GroupVoltageThStatus | 1.3.6.1.4.1.19536.10.1.3.1.1.6 | INTEGER | RO | good(1) | |||||||||||||||||
| Cpdug5GroupVoltageThLowerWarning | 1.3.6.1.4.1.19536.10.1.3.1.1.7 | Integer32 (-1..500000) | RO | 0 | |||||||||||||||||
column · Integer32 (-1..500000) · read-only · current Lower warning threshold. Units are 0.1 volts. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5GroupVoltageThLowerCritical | 1.3.6.1.4.1.19536.10.1.3.1.1.8 | Integer32 (-1..500000) | RO | 0 | |||||||||||||||||
column · Integer32 (-1..500000) · read-only · current Lower critical threshold. Units are 0.1 volts. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5GroupVoltageThUpperWarning | 1.3.6.1.4.1.19536.10.1.3.1.1.9 | Integer32 (-1..500000) | RO | 0 | |||||||||||||||||
column · Integer32 (-1..500000) · read-only · current Upper warning threshold. Units are 0.1 volts. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5GroupVoltageThUpperCritical | 1.3.6.1.4.1.19536.10.1.3.1.1.10 | Integer32 (-1..500000) | RO | 0 | |||||||||||||||||
column · Integer32 (-1..500000) · read-only · current Upper critical threshold. Units are 0.1 volts. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5groupCurrentRating | 1.3.6.1.4.1.19536.10.1.3.1.1.11 | Integer32 | RO | 1600 | |||||||||||||||||
column · Integer32 · read-only · current Rated current capacity of the group. Units are 0.01 amps. A negative value indicates that the hardware current capacity is unknown (it will always be unknown for custom groups). | |||||||||||||||||||||
| Cpdug5GroupCurrent | 1.3.6.1.4.1.19536.10.1.3.1.1.12 | Integer32 | RO | 193 | |||||||||||||||||
| Cpdug5GroupCurrentThStatus | 1.3.6.1.4.1.19536.10.1.3.1.1.13 | INTEGER | RO | good(1) | |||||||||||||||||
column · INTEGER · read-only · current Status of the measured group current relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdug5GroupCurrentThLowerWarning | 1.3.6.1.4.1.19536.10.1.3.1.1.14 | Integer32 (-1..100000) | RW | 0 | |||||||||||||||||
column · Integer32 (-1..100000) · read-write · current Lower warning threshold. Units are 0.01 amps. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5GroupCurrentThLowerCritical | 1.3.6.1.4.1.19536.10.1.3.1.1.15 | Integer32 (-1..100000) | RW | 0 | |||||||||||||||||
column · Integer32 (-1..100000) · read-write · current Lower critical threshold. Units are 0.01 amps. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5GroupCurrentThUpperWarning | 1.3.6.1.4.1.19536.10.1.3.1.1.16 | Integer32 (-1..100000) | RW | 1100 | |||||||||||||||||
| Cpdug5GroupCurrentThUpperCritical | 1.3.6.1.4.1.19536.10.1.3.1.1.17 | Integer32 (-1..100000) | RW | 1400 | |||||||||||||||||
| Cpdug5GroupCurrentPercentLoad | 1.3.6.1.4.1.19536.10.1.3.1.1.18 | Integer32 | RO | 12 | |||||||||||||||||
column · Integer32 · read-only · current Current percent load, based on the rated current capacity. Units are percentage, for example 80% will be returned as 80. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5GroupPowerVA | 1.3.6.1.4.1.19536.10.1.3.1.1.19 | Integer32 | RO | 454 | |||||||||||||||||
| Cpdug5GroupPowerWatts | 1.3.6.1.4.1.19536.10.1.3.1.1.20 | Integer32 | RO | 427 | |||||||||||||||||
| Cpdug5GroupPowerWattHour | 1.3.6.1.4.1.19536.10.1.3.1.1.21 | Integer32 | RO | 77384 | |||||||||||||||||
column · Integer32 · read-only · current A Watt-Hour value for each section. Units are WH. This value can be reset to 0 using GUI. In that case, the pdug5GroupPowerWattHourTimer will be reset as well. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5GroupPowerWattHourTimer | 1.3.6.1.4.1.19536.10.1.3.1.1.22 | DisplayString (SIZE (0..22)) | RO | 2018/07/16 16:26
3A 30 30 00 | |||||||||||||||||
| Cpdug5GroupPowerFactor | 1.3.6.1.4.1.19536.10.1.3.1.1.23 | Integer32 | RO | 94 | |||||||||||||||||
column · Integer32 · read-only · current A group PF value. Units are in hundredths, for example a power factor of 0.95 would be returned as 95, and 0.92 would be returned as 92. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5GroupPowerVAR | 1.3.6.1.4.1.19536.10.1.3.1.1.24 | Integer32 | RO | 156 | |||||||||||||||||
| Cpdug5GroupOutletCount | 1.3.6.1.4.1.19536.10.1.3.1.1.25 | Integer32 (0..48) | RO | 0 | |||||||||||||||||
column · Integer32 (0..48) · read-only · current The number of outlets in each group (breaker). Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5GroupBreakerStatus | 1.3.6.1.4.1.19536.10.1.3.1.1.26 | INTEGER | RO | breakerOn(2) | |||||||||||||||||
| Cpdug5GroupVoltageThCtrl | 1.3.6.1.4.1.19536.10.1.3.1.1.27 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Circuit Breaker voltage alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5GroupCurrentThCtrl | 1.3.6.1.4.1.19536.10.1.3.1.1.28 | Integer32 | RW | 12 | |||||||||||||||||
column · Integer32 · read-write · current Circuit Breaker current alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | |||||||||||||||||||||
| Npdug5Environment | 1.3.6.1.4.1.19536.10.1.4 | ||||||||||||||||||||
| Tpdug5EnvProbeTable | 1.3.6.1.4.1.19536.10.1.4.1 | NA | |||||||||||||||||||
table · not-accessible · current A list of environment probe (1 per PDU) for temperature, humidity, and contacts. The number of entries is given by number of PDUs in daisy chain. | |||||||||||||||||||||
| Rpdug5EnvProbeEntry | 1.3.6.1.4.1.19536.10.1.4.1.1 | NA | |||||||||||||||||||
| Cpdug5TemperatureScale | 1.3.6.1.4.1.19536.10.1.4.1.1.1 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Scale used to return temperature objects.
| |||||||||||||||||||||
| Cpdug5TemperatureCount | 1.3.6.1.4.1.19536.10.1.4.1.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of temperature measurements.The MAX is 6 (1 per probe). | |||||||||||||||||||||
| Cpdug5HumidityCount | 1.3.6.1.4.1.19536.10.1.4.1.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of humidity measurements.The MAX is 6(1 per probe). | |||||||||||||||||||||
| Cpdug5DoorCount | 1.3.6.1.4.1.19536.10.1.4.1.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of door sensors.The MAX is 6(1 per probe). | |||||||||||||||||||||
| Cpdug5DryCount | 1.3.6.1.4.1.19536.10.1.4.1.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of dry sensors.The MAX is 2(1 per probe). | |||||||||||||||||||||
| Cpdug5SpotCount | 1.3.6.1.4.1.19536.10.1.4.1.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of spot sensors.The MAX is 2(1 per probe). | |||||||||||||||||||||
| Cpdug5RopeCount | 1.3.6.1.4.1.19536.10.1.4.1.1.7 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of rope sensors.The MAX is 2(1 per probe). | |||||||||||||||||||||
| Cpdug5HidCount | 1.3.6.1.4.1.19536.10.1.4.1.1.10 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of hid sensors. The MAX is 2(1 per probe). | |||||||||||||||||||||
| Tpdug5TemperatureTable | 1.3.6.1.4.1.19536.10.1.4.2 | NA | |||||||||||||||||||
table · not-accessible · current A list of temperature probe measurements. The number of entries are given by number of pdu and pdug5TemperatureCount. | |||||||||||||||||||||
| Rpdug5TemperatureEntry | 1.3.6.1.4.1.19536.10.1.4.2.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry for a temperature measurement. | |||||||||||||||||||||
| Cpdug5TemperatureIndex | 1.3.6.1.4.1.19536.10.1.4.2.1.1 | Integer32 (1..6) | NA | ||||||||||||||||||
column · Integer32 (1..6) · not-accessible · current A unique value for each temperature probe measurement. Its value ranges from 1 to temperatureCount. | |||||||||||||||||||||
| Cpdug5TemperatureName | 1.3.6.1.4.1.19536.10.1.4.2.1.2 | DisplayString (SIZE (1..15)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (1..15)) · read-write · current A descriptive name for the temperature probe. | |||||||||||||||||||||
| Cpdug5TemperatureProbeStatus | 1.3.6.1.4.1.19536.10.1.4.2.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Indicates whether a probe is connected or not.
| |||||||||||||||||||||
| Cpdug5TemperatureValue | 1.3.6.1.4.1.19536.10.1.4.2.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Units are degree(either Fahrenheit or Celsius). | |||||||||||||||||||||
| Cpdug5TemperatureThStatus | 1.3.6.1.4.1.19536.10.1.4.2.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Status of the measured temperature relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdug5TemperatureThLowerWarning | 1.3.6.1.4.1.19536.10.1.4.2.1.6 | Integer32 (-1..150000) | RW | ||||||||||||||||||
column · Integer32 (-1..150000) · read-write · current Lower warning threshold. Units are degrees. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5TemperatureThLowerCritical | 1.3.6.1.4.1.19536.10.1.4.2.1.7 | Integer32 (-1..150000) | RW | ||||||||||||||||||
column · Integer32 (-1..150000) · read-write · current Lower critical threshold. Units are degrees. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5TemperatureThUpperWarning | 1.3.6.1.4.1.19536.10.1.4.2.1.8 | Integer32 (-1..150000) | RW | ||||||||||||||||||
column · Integer32 (-1..150000) · read-write · current Upper warning threshold. Units are degrees. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5TemperatureThUpperCritical | 1.3.6.1.4.1.19536.10.1.4.2.1.9 | Integer32 (-1..150000) | RW | ||||||||||||||||||
column · Integer32 (-1..150000) · read-write · current Upper critical threshold. Units are degrees. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5TemperatureThCtrl | 1.3.6.1.4.1.19536.10.1.4.2.1.10 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Temperature alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | |||||||||||||||||||||
| Tpdug5HumidityTable | 1.3.6.1.4.1.19536.10.1.4.3 | NA | |||||||||||||||||||
table · not-accessible · current A list of humidity probe measurements. The number of entries are given by number of pdu and pdug5HumidityCount. | |||||||||||||||||||||
| Rpdug5HumidityEntry | 1.3.6.1.4.1.19536.10.1.4.3.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry for a humidity measurement. | |||||||||||||||||||||
| Cpdug5HumidityIndex | 1.3.6.1.4.1.19536.10.1.4.3.1.1 | Integer32 (1..6) | NA | ||||||||||||||||||
column · Integer32 (1..6) · not-accessible · current A unique value for each humidity probe measurement. Its value ranges from 1 to pdug5HumidityCount per PDU. | |||||||||||||||||||||
| Cpdug5HumidityName | 1.3.6.1.4.1.19536.10.1.4.3.1.2 | DisplayString (SIZE (1..15)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (1..15)) · read-write · current A descriptive name for the humidity probe. | |||||||||||||||||||||
| Cpdug5HumidityProbeStatus | 1.3.6.1.4.1.19536.10.1.4.3.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Indicates whether a probe is connected or not.
| |||||||||||||||||||||
| Cpdug5HumidityValue | 1.3.6.1.4.1.19536.10.1.4.3.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Units are %RH. | |||||||||||||||||||||
| Cpdug5HumidityThStatus | 1.3.6.1.4.1.19536.10.1.4.3.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Status of the measured humidity relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdug5HumidityThLowerWarning | 1.3.6.1.4.1.19536.10.1.4.3.1.6 | Integer32 (-1..1000) | RW | ||||||||||||||||||
column · Integer32 (-1..1000) · read-write · current Lower warning threshold. Units are %RH. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5HumidityThLowerCritical | 1.3.6.1.4.1.19536.10.1.4.3.1.7 | Integer32 (-1..1000) | RW | ||||||||||||||||||
column · Integer32 (-1..1000) · read-write · current Lower critical threshold. Units are %RH. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5HumidityThUpperWarning | 1.3.6.1.4.1.19536.10.1.4.3.1.8 | Integer32 (-1..1000) | RW | ||||||||||||||||||
column · Integer32 (-1..1000) · read-write · current Upper warning threshold. Units are %RH. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5HumidityThUpperCritical | 1.3.6.1.4.1.19536.10.1.4.3.1.9 | Integer32 (-1..1000) | RW | ||||||||||||||||||
column · Integer32 (-1..1000) · read-write · current Upper critical threshold. Units are %RH. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdug5HumidityThCtrl | 1.3.6.1.4.1.19536.10.1.4.3.1.10 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Humidity alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | |||||||||||||||||||||
| Tpdug5DoorTable | 1.3.6.1.4.1.19536.10.1.4.4 | NA | |||||||||||||||||||
table · not-accessible · current A list of door sensors. The number of entries are given by number of PDU and pdug5DoorCount. | |||||||||||||||||||||
| Rpdug5DoorEntry | 1.3.6.1.4.1.19536.10.1.4.4.1 | NA | |||||||||||||||||||
| Cpdug5DoorIndex | 1.3.6.1.4.1.19536.10.1.4.4.1.1 | Integer32 (1..2) | NA | ||||||||||||||||||
column · Integer32 (1..2) · not-accessible · current A unique value for each door sensor. Its value ranges from 1 to doorCount. | |||||||||||||||||||||
| Cpdug5DoorName | 1.3.6.1.4.1.19536.10.1.4.4.1.2 | DisplayString (SIZE (1..15)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (1..15)) · read-write · current A descriptive name for the door sensor. | |||||||||||||||||||||
| Cpdug5DoorProbeStatus | 1.3.6.1.4.1.19536.10.1.4.4.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Indicates whether a probe is connected or not. Will not be returned if the door sensor is internal to the ePDU, in that case only doorState should be read.
| |||||||||||||||||||||
| Cpdug5DoorState | 1.3.6.1.4.1.19536.10.1.4.4.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The state of the door sensor.
| |||||||||||||||||||||
| Tpdug5DryTable | 1.3.6.1.4.1.19536.10.1.4.5 | NA | |||||||||||||||||||
table · not-accessible · current A list of dry sensors. The number of entries are given by number of pdu and pdug5DryCount. | |||||||||||||||||||||
| Rpdug5DryEntry | 1.3.6.1.4.1.19536.10.1.4.5.1 | NA | |||||||||||||||||||
| Cpdug5DryIndex | 1.3.6.1.4.1.19536.10.1.4.5.1.1 | Integer32 (1..2) | NA | ||||||||||||||||||
column · Integer32 (1..2) · not-accessible · current A unique value for each dry sensor. Its value ranges from 1 to dryCount. | |||||||||||||||||||||
| Cpdug5DryName | 1.3.6.1.4.1.19536.10.1.4.5.1.2 | DisplayString (SIZE (1..15)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (1..15)) · read-write · current A descriptive name for the dry sensor. | |||||||||||||||||||||
| Cpdug5DryProbeStatus | 1.3.6.1.4.1.19536.10.1.4.5.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Indicates whether a probe is connected or not.
| |||||||||||||||||||||
| Cpdug5DryState | 1.3.6.1.4.1.19536.10.1.4.5.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The state of the dry sensor.
| |||||||||||||||||||||
| Tpdug5SpotTable | 1.3.6.1.4.1.19536.10.1.4.6 | NA | |||||||||||||||||||
table · not-accessible · current A list of contact sensors. The number of entries are given by number of pdu and pdug5SpotCount. | |||||||||||||||||||||
| Rpdug5SpotEntry | 1.3.6.1.4.1.19536.10.1.4.6.1 | NA | |||||||||||||||||||
| Cpdug5SpotIndex | 1.3.6.1.4.1.19536.10.1.4.6.1.1 | Integer32 (1..3) | NA | ||||||||||||||||||
column · Integer32 (1..3) · not-accessible · current A unique value for each spot sensor. Its value ranges from 1 to spotCount. | |||||||||||||||||||||
| Cpdug5SpotName | 1.3.6.1.4.1.19536.10.1.4.6.1.2 | DisplayString (SIZE (1..15)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (1..15)) · read-write · current A descriptive name for the spot sensor. | |||||||||||||||||||||
| Cpdug5SpotProbeStatus | 1.3.6.1.4.1.19536.10.1.4.6.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Indicates whether a probe is connected or not.
| |||||||||||||||||||||
| Cpdug5SpotState | 1.3.6.1.4.1.19536.10.1.4.6.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The state of the spot sensor.
| |||||||||||||||||||||
| Tpdug5RopeTable | 1.3.6.1.4.1.19536.10.1.4.7 | NA | |||||||||||||||||||
table · not-accessible · current A list of rope sensors. The number of entries are given by number of pdu and pdug5RopeCount. | |||||||||||||||||||||
| Rpdug5RopeEntry | 1.3.6.1.4.1.19536.10.1.4.7.1 | NA | |||||||||||||||||||
| Cpdug5RopeIndex | 1.3.6.1.4.1.19536.10.1.4.7.1.1 | Integer32 (1..3) | NA | ||||||||||||||||||
column · Integer32 (1..3) · not-accessible · current A unique value for each rope sensor. Its value ranges from 1 to ropeCount. | |||||||||||||||||||||
| Cpdug5RopeName | 1.3.6.1.4.1.19536.10.1.4.7.1.2 | DisplayString (SIZE (1..15)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (1..15)) · read-write · current A descriptive name for the rope sensor. | |||||||||||||||||||||
| Cpdug5RopeProbeStatus | 1.3.6.1.4.1.19536.10.1.4.7.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Indicates whether a probe is connected or not.
| |||||||||||||||||||||
| Cpdug5RopeState | 1.3.6.1.4.1.19536.10.1.4.7.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The state of the rope sensor.
| |||||||||||||||||||||
| Npdug5EnvHID | 1.3.6.1.4.1.19536.10.1.4.10 | ||||||||||||||||||||
| Tpdug5EnvHidTable | 1.3.6.1.4.1.19536.10.1.4.10.1 | NA | |||||||||||||||||||
table · not-accessible · current A list of contact sensors. The number of entries are given by number of pdu and pdug5HidCount. | |||||||||||||||||||||
| Rpdug5EnvHidEntry | 1.3.6.1.4.1.19536.10.1.4.10.1.1 | NA | |||||||||||||||||||
| Cpdug5HIDIndex | 1.3.6.1.4.1.19536.10.1.4.10.1.1.1 | Integer32 (1..2) | NA | ||||||||||||||||||
column · Integer32 (1..2) · not-accessible · current The index of the PDU HID table entry | |||||||||||||||||||||
| Cpdug5HidAisle | 1.3.6.1.4.1.19536.10.1.4.10.1.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Aisle of HID handle.
| |||||||||||||||||||||
| Cpdug5HidHandleOperation | 1.3.6.1.4.1.19536.10.1.4.10.1.1.3 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current HID handle control operations
| |||||||||||||||||||||
| CpduHIDVer | 1.3.6.1.4.1.19536.10.1.4.10.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · current The firmware revision level of the HID | |||||||||||||||||||||
| Cpdug5MechanicalLock | 1.3.6.1.4.1.19536.10.1.4.10.1.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current HID Mechanical operations
| |||||||||||||||||||||
| CpduHIDSerial | 1.3.6.1.4.1.19536.10.1.4.10.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · current The Serial Number of the HID | |||||||||||||||||||||
| CpduHIDHwVer | 1.3.6.1.4.1.19536.10.1.4.10.1.1.7 | DisplayString (SIZE (0..63)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · current The hardware revision level of the HID | |||||||||||||||||||||
| Cpdug5HIDAutoLockTime | 1.3.6.1.4.1.19536.10.1.4.10.1.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current HID Electronic Latch Autolock Time in seconds, Value ranges (0-999) | |||||||||||||||||||||
| Cpdug5HIDDoorOpenTime | 1.3.6.1.4.1.19536.10.1.4.10.1.1.9 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current HID Door Open Time in seconds, Value ranges (0-999) | |||||||||||||||||||||
| Cpdug5HIDMaxDoorOpenTime | 1.3.6.1.4.1.19536.10.1.4.10.1.1.10 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current HID Max Door Open Time in seconds, Value ranges (0-32400), critical alarm will be raised if door is left open past this time | |||||||||||||||||||||
| Cpdug5HIDUserPinLength | 1.3.6.1.4.1.19536.10.1.4.10.1.1.11 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Rack Access User minimum PIN Length, value ranges(0-16) | |||||||||||||||||||||
| Cpdug5HIDUserPinMode | 1.3.6.1.4.1.19536.10.1.4.10.1.1.12 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Rack Access User PIN mode setting
| |||||||||||||||||||||
| Cpdug5HIDAisleControl | 1.3.6.1.4.1.19536.10.1.4.10.1.1.13 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Rack Access Aisle Control setting, when set to standalone each aisle will controlled separately, when set to combined opposite aisle can be controlled with authenticated control action on either aisle
| |||||||||||||||||||||
| Cpdug5HIDBeaconFuncControl | 1.3.6.1.4.1.19536.10.1.4.10.1.1.14 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Beacon Function Control
| |||||||||||||||||||||
| Cpdug5HidBeaconColorControl | 1.3.6.1.4.1.19536.10.1.4.10.1.1.15 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Beacon Color Control
| |||||||||||||||||||||
| Tpdug5EnvHidControlTable | 1.3.6.1.4.1.19536.10.1.4.10.2 | NA | |||||||||||||||||||
table · not-accessible · current A list of smartcard. The number of entries are given by number of pdu and pdug5HidCount. | |||||||||||||||||||||
| Rpdug5EnvHidControlEntry | 1.3.6.1.4.1.19536.10.1.4.10.2.1 | NA | |||||||||||||||||||
row · not-accessible · current The smart card table entry containing the username, cardid, cardaisle etc. | |||||||||||||||||||||
| Cpdug5HidControlIndex | 1.3.6.1.4.1.19536.10.1.4.10.2.1.1 | Integer32 (1..200) | NA | ||||||||||||||||||
column · Integer32 (1..200) · not-accessible · current The index of the PDU smartcard table entry | |||||||||||||||||||||
| Cpdug5HidControlUserName | 1.3.6.1.4.1.19536.10.1.4.10.2.1.2 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current User name of smartcard. Use #delete# to delete the HID user | |||||||||||||||||||||
| Cpdug5HidControlCardID | 1.3.6.1.4.1.19536.10.1.4.10.2.1.3 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current HID smartcard ID. | |||||||||||||||||||||
| Cpdug5HidControlTimestamp | 1.3.6.1.4.1.19536.10.1.4.10.2.1.4 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current Indicates the date and time of accessing | |||||||||||||||||||||
| Cpdug5HidControlCardAisle | 1.3.6.1.4.1.19536.10.1.4.10.2.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Aisle of authorized card
| |||||||||||||||||||||
| Cpdug5HidControlStartTime | 1.3.6.1.4.1.19536.10.1.4.10.2.1.6 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current Indicates the start date and time Rack access user is given access | |||||||||||||||||||||
| Cpdug5HidControlExpireTime | 1.3.6.1.4.1.19536.10.1.4.10.2.1.7 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current Indicates the date and time when the access of user card will expire, To set expire time first set user as temporary user | |||||||||||||||||||||
| Cpdug5HidControlTempUser | 1.3.6.1.4.1.19536.10.1.4.10.2.1.8 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Indicates if the card user has temporary access
| |||||||||||||||||||||
| Cpdug5HidControlPin | 1.3.6.1.4.1.19536.10.1.4.10.2.1.9 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current Rack access control entry keypad PIN | |||||||||||||||||||||
| Cpdug5HidControlCardIdStr | 1.3.6.1.4.1.19536.10.1.4.10.2.1.10 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current Smartrack Access Card ID String | |||||||||||||||||||||
| Npdug5Outlet | 1.3.6.1.4.1.19536.10.1.5 | ||||||||||||||||||||
| Tpdug5OutletTable | 1.3.6.1.4.1.19536.10.1.5.1 | NA | |||||||||||||||||||
table · not-accessible · current Aggregate Object with number of entries equal to Number of PDU (pdug5IdentIndex) and Number of outlet per PDU (pdug5OutletIndex). | |||||||||||||||||||||
| Rpdug5OutletEntry | 1.3.6.1.4.1.19536.10.1.5.1.1 | NA | |||||||||||||||||||
row · not-accessible · current The Outlet table entry containing the type, voltage, current etc. | |||||||||||||||||||||
| Cpdug5OutletIndex | 1.3.6.1.4.1.19536.10.1.5.1.1.1 | Integer32 (0..48) | NA | 1 | |||||||||||||||||
column · Integer32 (0..48) · not-accessible · current Index for each outlet, value from 1 to the number of outlets per PDU. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletName | 1.3.6.1.4.1.19536.10.1.5.1.1.2 | DisplayString (SIZE (1..31)) | RW | OUTLET 1 | |||||||||||||||||
column · DisplayString (SIZE (1..31)) · read-write · current A descriptive name for the outlet. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletType | 1.3.6.1.4.1.19536.10.1.5.1.1.3 | INTEGER | RO | iecC19(2) | |||||||||||||||||
column · INTEGER · read-only · current Type of this outlet - C13, C19, 5-20R, iecC13/C15 COMBO, iecC13/C15/C19 COMBO...
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletCurrentRating | 1.3.6.1.4.1.19536.10.1.5.1.1.4 | Integer32 | RO | 1600 | |||||||||||||||||
column · Integer32 · read-only · current Rated current capacity of this outlet. Units are 0.01 amps. A negative value indicates that the hardware current capacity is unknown. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletCurrent | 1.3.6.1.4.1.19536.10.1.5.1.1.5 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current A outlet current measurement value. Units are 0.01 amps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletActivePowerThStatus | 1.3.6.1.4.1.19536.10.1.5.1.1.6 | INTEGER | RO | good(1) | |||||||||||||||||
column · INTEGER · read-only · current Status of the measured outlet active power relative to the configured thresholds.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletActivePowerThLowerWarning | 1.3.6.1.4.1.19536.10.1.5.1.1.7 | Integer32 (-1..10000) | RW | 0 | |||||||||||||||||
column · Integer32 (-1..10000) · read-write · current Lower warning threshold. Units are Watts(W). A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletActivePowerThLowerCritical | 1.3.6.1.4.1.19536.10.1.5.1.1.8 | Integer32 (-1..10000) | RW | 0 | |||||||||||||||||
column · Integer32 (-1..10000) · read-write · current Lower critical threshold. Units are Watts(W). A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletActivePowerThUpperWarning | 1.3.6.1.4.1.19536.10.1.5.1.1.9 | Integer32 (-1..10000) | RW | 0 | |||||||||||||||||
column · Integer32 (-1..10000) · read-write · current Upper warning threshold. Units are Watts(W). A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletActivePowerThUpperCritical | 1.3.6.1.4.1.19536.10.1.5.1.1.10 | Integer32 (-1..10000) | RW | 0 | |||||||||||||||||
column · Integer32 (-1..10000) · read-write · current Upper critical threshold. Units are Watts(W). A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletCurrentPercentLoad | 1.3.6.1.4.1.19536.10.1.5.1.1.11 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Current percent load, based on the rated current capacity. Units are percentage, for example 80% will be returned as 80. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletVA | 1.3.6.1.4.1.19536.10.1.5.1.1.12 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current A outlet VA value. Units are VA. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletWatts | 1.3.6.1.4.1.19536.10.1.5.1.1.13 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current A outlet Watts value. Units are Watts. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletWh | 1.3.6.1.4.1.19536.10.1.5.1.1.14 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current A Watt-Hour value for each outlet. Units are WH. This object is writable so that it can be reset to 0. When it is written to, the pdug5OutletWhTimer will be reset updated as well A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletWhTimer | 1.3.6.1.4.1.19536.10.1.5.1.1.15 | DisplayString (SIZE (0..22)) | RO | 2024/03/29 15:20:03 | |||||||||||||||||
column · DisplayString (SIZE (0..22)) · read-only · current Timestamp (date and time) of outlet Watt-hours was last reset. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletPowerFactor | 1.3.6.1.4.1.19536.10.1.5.1.1.16 | Integer32 | RO | 100 | |||||||||||||||||
column · Integer32 · read-only · current An outlet PF value. Units are in hundredths, for example a power factor of 0.95 would be returned as 95, and 0.92 would be returned as 92. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletVAR | 1.3.6.1.4.1.19536.10.1.5.1.1.17 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current An outlet VAR value. Units are VAR. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletBranch | 1.3.6.1.4.1.19536.10.1.5.1.1.18 | Integer32 | RO | 1 | |||||||||||||||||
column · Integer32 · read-only · current The branch number outlet located. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletActivePowerThResetThld | 1.3.6.1.4.1.19536.10.1.5.1.1.19 | Integer32 (-1..10000) | RW | 0 | |||||||||||||||||
column · Integer32 (-1..10000) · read-write · current The Reset threshold is the number of watss the reading needs to fall below the threshold setting for the condition to be cleared. Units are watts. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletActivePowerThChangeDelay | 1.3.6.1.4.1.19536.10.1.5.1.1.20 | Integer32 (0..100) | RW | 0 | |||||||||||||||||
column · Integer32 (0..100) · read-write · current The number of consecutive sample that the condition is present before an alarm is raised. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdug5OutletActivePowerThCtrl | 1.3.6.1.4.1.19536.10.1.5.1.1.21 | Integer32 | RW | 15 | |||||||||||||||||
column · Integer32 · read-write · current Outlet Active Power alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tpdug5OutletControlTable | 1.3.6.1.4.1.19536.10.1.5.2 | NA | |||||||||||||||||||
table · not-accessible · current Aggregate Object with number of entries equal to Number of PDU (pdug5IdentIndex) and Number of outlets per PDU (pdug5OutletIndex). | |||||||||||||||||||||
| Rpdug5OutletControlEntry | 1.3.6.1.4.1.19536.10.1.5.2.1 | NA | |||||||||||||||||||
row · not-accessible · current The Outlet table entry containing the type, voltage, current etc. | |||||||||||||||||||||
| Cpdug5OutletControlStatus | 1.3.6.1.4.1.19536.10.1.5.2.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current current state of a control outlet.
| |||||||||||||||||||||
| Cpdug5OutletControlOffCmd | 1.3.6.1.4.1.19536.10.1.5.2.1.2 | Integer32 (-1..99999) | RW | ||||||||||||||||||
column · Integer32 (-1..99999) · read-write · current When write, once issued, the outlet will turn Off immediately. 0-n: Time in seconds until the outlet command is issued -1: Cancel a pending outlet Off command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. | |||||||||||||||||||||
| Cpdug5OutletControlOnCmd | 1.3.6.1.4.1.19536.10.1.5.2.1.3 | Integer32 (-1..99999) | RW | ||||||||||||||||||
column · Integer32 (-1..99999) · read-write · current When write, once issued, the outlet will turn On immediately. 0-n: Time in seconds until the outlet command is issued -1: Cancel a pending outlet On command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. | |||||||||||||||||||||
| Cpdug5OutletControlRebootCmd | 1.3.6.1.4.1.19536.10.1.5.2.1.4 | Integer32 (-1..99999) | RW | ||||||||||||||||||
column · Integer32 (-1..99999) · read-write · current When write, for outlets that are On prior to this Reboot command, they will switch Off immediately when the command is issued, remain Off for outletControlRebootOffTime seconds, and then turn back On. For outlets that are Off prior to the Reboot command, they will turn On after a delay of outletControlRebootOffTime seconds from when the command is issued. 0-n : Time in seconds until the Reboot command is issued -1 : Cancel a pending outlet Reboot command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. | |||||||||||||||||||||
| Cpdug5OutletControlPowerOnState | 1.3.6.1.4.1.19536.10.1.5.2.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Determines the outlet state when power is applied to the unit. 1 : not restart at device startup 2 : should sequence back ON in line with outletControlSequenceTime 3 : should take the state the outlet had when power was lost. If the state was ON, should sequence back ON in line with outletControlSequenceTime.
| |||||||||||||||||||||
| Cpdug5OutletControlSequenceDelay | 1.3.6.1.4.1.19536.10.1.5.2.1.6 | Integer32 (-1..7200) | RW | ||||||||||||||||||
column · Integer32 (-1..7200) · read-write · current Time delay in seconds from when a Global Sequence On command is issued to when the command is executed on this outlet. This delay is also used as a power-on delay. | |||||||||||||||||||||
| Cpdug5OutletControlRebootOffTime | 1.3.6.1.4.1.19536.10.1.5.2.1.7 | Integer32 (5..60) | RW | ||||||||||||||||||
column · Integer32 (5..60) · read-write · current Time delay in seconds that the outlet should remain in the Off state when executing a Reboot command. | |||||||||||||||||||||
| Cpdug5OutletControlSwitchable | 1.3.6.1.4.1.19536.10.1.5.2.1.8 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Determines the outlet capability to be controlled On/Off from the communication channels. 1 : control On/Off enabled 2 : control On/Off disabled.
| |||||||||||||||||||||
| Cpdug5OutletControlShutoffDelay | 1.3.6.1.4.1.19536.10.1.5.2.1.9 | Integer32 (-1..7200) | RW | ||||||||||||||||||
column · Integer32 (-1..7200) · read-write · current Time delay in seconds that could be taken in account before shutting of the outlet. An application which need to shutoff properly an outlet will read this parameter first then write it to the command pdug5OutletControlOffCmd. | |||||||||||||||||||||
| Cpdug5OutletControlCommand | 1.3.6.1.4.1.19536.10.1.5.2.1.10 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Getting this variable will return the outlet state. If the outlet is on, the immediateOn (2) value will be returned. If the outlet is off, the immediateOff (1) value will be returned. If the state of the outlet cannot be determined, the outletUnknown (7) value will be returned. If the outletUnknown condition should occur, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition. Setting this variable to immediateOn (2) will immediately turn the outlet on. Setting this variable to immediateOff (1) will immediately turn the outlet off. Setting this variable to immediateReboot (5) will cause the Switched PDU to perform an immediateOff command, wait the pdug5OutletControlRebootOffTime OID time, and then perform an immediateOn command. Setting this variable to delayedOn (4) will turn the outlet on after the pdug5OutletControlSequenceDelay OID time has elapsed. Setting this variable to delayedOff (3) will turn the outlet off after the pdug5OutletControlShutoffDelay OID time has elapsed. Setting this variable to delayedReboot (6) will cause the Switched PDU to perform a delayedOff command, wait the pdug5OutletControlRebootOffTime OID time, and then perform a delayedOn command.
| |||||||||||||||||||||
| Tpdug5OutletGroupTable | 1.3.6.1.4.1.19536.10.1.5.3 | NA | |||||||||||||||||||
table · not-accessible · current Aggregate Object with Number of outlets per Group (pdug5OutletGroupsIndex). | |||||||||||||||||||||
| Rpdug5OutletGroupEntry | 1.3.6.1.4.1.19536.10.1.5.3.1 | NA | |||||||||||||||||||
row · not-accessible · current The Outlet Group table entry containing the count, name, member etc. | |||||||||||||||||||||
| Cpdug5OutletGroupCount | 1.3.6.1.4.1.19536.10.1.5.3.1.1 | Integer32 (0..256) | RO | ||||||||||||||||||
column · Integer32 (0..256) · read-only · current The numeric Switched Outlet Groups Count | |||||||||||||||||||||
| Cpdug5OutletGroupName | 1.3.6.1.4.1.19536.10.1.5.3.1.2 | DisplayString (SIZE (1..64)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (1..64)) · read-write · current The user-defined switched outlet Groups Name string | |||||||||||||||||||||
| Cpdug5OutletGroupMemberID | 1.3.6.1.4.1.19536.10.1.5.3.1.3 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current The user-defined switched outlet Group Members string | |||||||||||||||||||||
| Cpdug5OutletGroupControl | 1.3.6.1.4.1.19536.10.1.5.3.1.4 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current Getting this variable will return the group state. If the group is on, the immediateOn (2) value will be returned. If the group is off, the immediateOff (1) value will be returned. If the state of the group cannot be determined, the outletUnknown (7) value will be returned. If the outletUnknown condition should occur, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition. Setting this variable to immediateOn (2) will immediately turn the group on. Setting this variable to immediateOff (1) will immediately turn the group off. Setting this variable to immediateReboot (5) will cause the Switched PDU to perform an immediateOff command, wait the pdug5OutletControlRebootOffTime OID time, and then perform an immediateOn command. Setting this variable to delayedOn (4) will turn the group on after the pdug5OutletControlSequenceDelay OID time has elapsed. Setting this variable to delayedOff (3) will turn the group off after the pdug5OutletControlShutoffDelay OID time has elapsed. Setting this variable to delayedReboot (6) will cause the Switched PDU to perform a delayedOff command, wait the pdug5OutletControlRebootOffTime OID time, and then perform a delayedOn command. | |||||||||||||||||||||
| Cpdug5OutletGroupActivePower | 1.3.6.1.4.1.19536.10.1.5.3.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The Sum of Active power of all Grouped Outlet. | |||||||||||||||||||||
| Cpdug5OutletGroupApparentPower | 1.3.6.1.4.1.19536.10.1.5.3.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The Sum of Apparent power of all Grouped Outlet. | |||||||||||||||||||||
| Npdug5Traps | 1.3.6.1.4.1.19536.10.1.6 | ||||||||||||||||||||
| !trapCritical | 1.3.6.1.4.1.19536.10.1.6.1 | ||||||||||||||||||||
notification · current A critical alarm has occurred. | |||||||||||||||||||||
| !trapWarning | 1.3.6.1.4.1.19536.10.1.6.2 | ||||||||||||||||||||
notification · current A warning alarm has occurred. | |||||||||||||||||||||
| !trapInformation | 1.3.6.1.4.1.19536.10.1.6.3 | ||||||||||||||||||||
notification · current An informational alarm has occurred. | |||||||||||||||||||||
| !trapCleared | 1.3.6.1.4.1.19536.10.1.6.4 | ||||||||||||||||||||
notification · current An alarm has cleared. | |||||||||||||||||||||
| !trapTest | 1.3.6.1.4.1.19536.10.1.6.5 | ||||||||||||||||||||
notification · current Test trap sent to a trap receiver to check proper reception of traps | |||||||||||||||||||||
| Npdug5TrapInfo | 1.3.6.1.4.1.19536.10.1.7 | ||||||||||||||||||||
| Npdug5TrapInfoEntry | 1.3.6.1.4.1.19536.10.1.7.1 | ||||||||||||||||||||
| StrapCode | 1.3.6.1.4.1.19536.10.1.7.1.1 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current A number identifying the event for the trap that was sent. | |||||||||||||||||||||
| StrapDescription | 1.3.6.1.4.1.19536.10.1.7.1.2 | DisplayString (SIZE (0..255)) | RO | ||||||||||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current A string identifying the event for that last trap that was sent. | |||||||||||||||||||||
| Npdug5Conformance | 1.3.6.1.4.1.19536.10.1.8 | ||||||||||||||||||||
| Npdug5Compliances | 1.3.6.1.4.1.19536.10.1.8.1 | ||||||||||||||||||||
| Mpdug5FullCompliance | 1.3.6.1.4.1.19536.10.1.8.1.1 | ||||||||||||||||||||
compliance · current Compliance statement | |||||||||||||||||||||
| Npdug5Groups | 1.3.6.1.4.1.19536.10.1.8.2 | ||||||||||||||||||||
| Gpdug5IdentGroup | 1.3.6.1.4.1.19536.10.1.8.2.1 | ||||||||||||||||||||
group · current the pdug5Identity defines objects which aid PDU system level configuration
| |||||||||||||||||||||
| Gpdug5InputGroup | 1.3.6.1.4.1.19536.10.1.8.2.2 | ||||||||||||||||||||
group · current the pdug5InputGroup defines objects which aid Input level configuration and monitoring
| |||||||||||||||||||||
| Gpdug5GroupGroup | 1.3.6.1.4.1.19536.10.1.8.2.3 | ||||||||||||||||||||
group · current the pdug5GroupGroup defines objects which aid Breaker level configuration and monitoring
| |||||||||||||||||||||
| Gpdug5EnvironmentGroup | 1.3.6.1.4.1.19536.10.1.8.2.4 | ||||||||||||||||||||
group · current the pdug5Environmental defines objects which aid Environmental level configuration and monitoring
| |||||||||||||||||||||
| Gpdug5OutletGroup | 1.3.6.1.4.1.19536.10.1.8.2.5 | ||||||||||||||||||||
group · current the pdug5OutletGroup defines objects which aid Outlet level configuration and monitoring
| |||||||||||||||||||||
| Gpdug5TrapGroup | 1.3.6.1.4.1.19536.10.1.8.2.6 | ||||||||||||||||||||
group · current the pdug5TrapGroup defines Traps.
| |||||||||||||||||||||
| Gpdug5TrapInfoGroup | 1.3.6.1.4.1.19536.10.1.8.2.7 | ||||||||||||||||||||
Traps / Notifications
- trapCleared
1.3.6.1.4.1.19536.10.1.6.4 - trapCritical
1.3.6.1.4.1.19536.10.1.6.1 - trapInformation
1.3.6.1.4.1.19536.10.1.6.3 - trapTest
1.3.6.1.4.1.19536.10.1.6.5 - trapWarning
1.3.6.1.4.1.19536.10.1.6.2