SL-EDFA-MIB
PacketLight Networks Ltd.This MIB module describes the EDFA Cards
snmptranslate -m SL-EDFA-MIB -Tpsnmpwalk -v2c -c <community> -m SL-EDFA-MIB <host> 1.3.6.1.4.1.4515.1.9Imports
| IF-MIB | InterfaceIndex |
|---|---|
| PerfHist-TC-MIB | PerfCurrentCount, PerfIntervalCount, PerfTotalCount |
| SL-NE-MIB | sitelight |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION, TimeStamp, TruthValue |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IslEdfa | 1.3.6.1.4.1.4515.1.9 | ||||||||||||
identity This MIB module describes the EDFA Cards | |||||||||||||
| NedfaConfig | 1.3.6.1.4.1.4515.1.9.1 | ||||||||||||
| TedfaConfigTable | 1.3.6.1.4.1.4515.1.9.1.1 | NA | |||||||||||
table · not-accessible · current The EDFA configuration table. | |||||||||||||
| RedfaConfigEntry | 1.3.6.1.4.1.4515.1.9.1.1.1 | NA | |||||||||||
row · not-accessible · current An entry in the EDFA interface configuration table. The index to this table is the same as the an ifIndex.
| |||||||||||||
| CedfaIfIndex | 1.3.6.1.4.1.4515.1.9.1.1.1.1 | InterfaceIndex | RO | 13681408 | |||||||||
column · InterfaceIndex · read-only · current The amplifier interface index. Example values from LibreNMS test devices
| |||||||||||||
| CedfaPumpTemp | 1.3.6.1.4.1.4515.1.9.1.1.1.2 | Integer32 | RO | 250 | |||||||||
column · Integer32 · read-only · current The pump temperture (in Kelvin). Example values from LibreNMS test devices
| |||||||||||||
| CedfaRxPower | 1.3.6.1.4.1.4515.1.9.1.1.1.3 | INTEGER | RO | 3 | |||||||||
column · INTEGER · read-only · current The measured Rx Power. The value is specified in ten'th of Dbm units increments, starting from -30.0 dbm (e.g. value 0 means -30.0 dbm). Example values from LibreNMS test devices
| |||||||||||||
| CedfaPumpAdminStatus | 1.3.6.1.4.1.4515.1.9.1.1.1.4 | INTEGER | RW | 0 | |||||||||
column · INTEGER · read-write · current The desired state of the laser. The restart(3) state indicates that the edfa pump should be restarted. The restart(3) is not a state, thus it is not kept in the configuration file.
Example values from LibreNMS test devices
| |||||||||||||
| CedfaPumpOperStatus | 1.3.6.1.4.1.4515.1.9.1.1.1.5 | INTEGER | RO | 3592 | |||||||||
column · INTEGER · read-only · current The current operational state of the laser. If edfaPumpAdminStatus is down(2) then edfaPumpOperStatus should be down(2). If edfaPumpAdminStatus is changed to up(1) then edfaPumpOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic; it should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state. The operational status is equal to restart(3) if the edfa pump is still in restart process.
Example values from LibreNMS test devices
| |||||||||||||
| CedfaStatus | 1.3.6.1.4.1.4515.1.9.1.1.1.6 | INTEGER (1..8191) | RO | 0 | |||||||||
column · INTEGER (1..8191) · read-only · current This variable indicates the Line Status of the
Edfa module.
The edfaStatus is a bit map represented as a
sum, therefore, it can represent multiple failures (alarms)
simultaneously.
edfaNoAlarm must be set if and only if no other
flag is set.
The various bit positions are:
1 edfaNoAlarm No alarm present
2 edfaPumpTemperuture Pump temperatur is out-of-bound
4 edfaPumpWavelength Pump wavelength is out-of-bound
8 edfaHwFail Pump HW failure
16 edfaRvcSignalDetect Loss of input signal
32 edfaPumpPower Pump power is out-of-bound
64 edfaRcvPower Rx Power is out-of-bound
128 edfaTemprature Edfa temperature is out-of-bound
256 edfaEyeSafty Eye safety alarm (available only in eye-safety mode)
512 edafGainFlatness Gain flatness alarm
1024 edfaXmtPower Tx Power is out-of-bound
2048 edfaGain Edfa Gain is out-of-bound
4096 edfaEol Pump End Of LifeExample values from LibreNMS test devices
| |||||||||||||
| CedfaVoa | 1.3.6.1.4.1.4515.1.9.1.1.1.7 | INTEGER | RO | 0 | |||||||||
column · INTEGER · read-only · current The computed VOA output attenuation specified in 0.1 dB units. From 0.0 to +15.0 dB. Example values from LibreNMS test devices
| |||||||||||||
| CedfaAutomaticMode | 1.3.6.1.4.1.4515.1.9.1.1.1.8 | TruthValue | RW | 0 | |||||||||
column · TruthValue · read-write · current Defines the Edfa automatic mode. If equals TRUE, the Edfa control mode should selected automaticaly. Otherwise it should be selected manualy. Example values from LibreNMS test devices
| |||||||||||||
| CedfaAdminControlMode | 1.3.6.1.4.1.4515.1.9.1.1.1.9 | INTEGER | RW | agc(2) | |||||||||
column · INTEGER · read-write · current Configure the Edfa control mode. This object may be set only when edfaAtomaticMode is FALSE.
Example values from LibreNMS test devices
| |||||||||||||
| CedfaOperControlMode | 1.3.6.1.4.1.4515.1.9.1.1.1.10 | INTEGER | RO | agc(2) | |||||||||
column · INTEGER · read-only · current The current Edfa control mode. Initialy the Edfa starts in APC mode. The AGC mode is used only when selected manualy or after transient input power change.
Example values from LibreNMS test devices
| |||||||||||||
| CedfaAdminGain | 1.3.6.1.4.1.4515.1.9.1.1.1.11 | INTEGER | RW | 170 | |||||||||
column · INTEGER · read-write · current The required Edfa Gain value given in 0.1 dB units. This value may be configured only when the edfa automatic mode is FALSE and the edfa control mode is Agc. Example values from LibreNMS test devices
| |||||||||||||
| CedfaOperGain | 1.3.6.1.4.1.4515.1.9.1.1.1.12 | INTEGER | RO | 170 | |||||||||
column · INTEGER · read-only · current The actual Edfa Gain value given in 0.1 dB units. Value range starts with 0.0 dbm Example values from LibreNMS test devices
| |||||||||||||
| CedfaAdminOutputPower | 1.3.6.1.4.1.4515.1.9.1.1.1.13 | INTEGER | RW | 120 | |||||||||
column · INTEGER · read-write · current The required Edfa output power value given in 0.1 dBm units. The range starts with -30.0 dBm. This value may be configured only when the edfa control mode is Apc. Example values from LibreNMS test devices
| |||||||||||||
| CedfaOperOutputPower | 1.3.6.1.4.1.4515.1.9.1.1.1.14 | INTEGER | RO | 174 | |||||||||
column · INTEGER · read-only · current The actual Edfa output power value specified in 0.1 dBm units. Valid valuse are in the range of 0.0 dBm upto +15.0 dBm. Example values from LibreNMS test devices
| |||||||||||||
| CedfaChannelsNumber | 1.3.6.1.4.1.4515.1.9.1.1.1.15 | INTEGER | RO | 44 | |||||||||
column · INTEGER · read-only · current The number of optical channels on this signal. Example values from LibreNMS test devices
| |||||||||||||
| CedfaTotalChannelsNumber | 1.3.6.1.4.1.4515.1.9.1.1.1.16 | INTEGER | RO | 0 | |||||||||
column · INTEGER · read-only · current The total number of optical channels on this fiber. Example values from LibreNMS test devices
| |||||||||||||
| CedfaEyeSafetyMode | 1.3.6.1.4.1.4515.1.9.1.1.1.17 | TruthValue | RW | 1 | |||||||||
column · TruthValue · read-write · current When in Eye-Safety mode the edfa reduces the laser power budget down to safe level upon detection of an output fiber cut. Example values from LibreNMS test devices
| |||||||||||||
| CedfaShutDownLipEnable | 1.3.6.1.4.1.4515.1.9.1.1.1.18 | TruthValue | RW | 0 | |||||||||
column · TruthValue · read-write · current EDFA shout-down on LIP (Loss of signal) - enable/disable. Example values from LibreNMS test devices
| |||||||||||||
| CedfaAutoPowerUpLipEnable | 1.3.6.1.4.1.4515.1.9.1.1.1.19 | TruthValue | RW | 0 | |||||||||
column · TruthValue · read-write · current EDFA automatic power up (after signal returns) - enable/disable. Example values from LibreNMS test devices
| |||||||||||||
| CedfaMaxGain | 1.3.6.1.4.1.4515.1.9.1.1.1.20 | INTEGER | RO | 0 | |||||||||
column · INTEGER · read-only · current The EDFA max gain is determined by the result of the VER command. Legal values: gainUnknown(1) gain14dbm(2) - Booster/Inline, (-2)-14dBm output power, gain (-5)-22dB gain17dbm(3) - Booster/Inline, (-2)-17dBm output power, gain (-5)-22dB gain20dbm(4) - Booster/Inline, (-2)-20dBm output power, gain (-5)-22dB gain23dbm(5) - Booster/Inline, 5-23dBm output power, gain (-5)-22dB, 16 channels gain18dbmPreAmp8Ch(6) - Preamp (-18)-5dBm output power, fixed gain 18dB gain18dbmPreAmp16ChRed(7) - Preamp (-18)-5dBm output power, fixed gain 18dB gain18dbmPreAmp16ChBlue(8)- Preamp (-18)-0dBm output power, fixed gain 18dB gain23dbmGain10(9) - Booster/Inline, 23dBm output power with fixed gain of 10dB, 32 channels Example values from LibreNMS test devices
| |||||||||||||
| CedfaGainInFrom | 1.3.6.1.4.1.4515.1.9.1.1.1.21 | INTEGER | RO | 8 | |||||||||
column · INTEGER · read-only · current Lower input gain range of the edfa in units of 0.1 db. Example values from LibreNMS test devices
| |||||||||||||
| CedfaGainInTo | 1.3.6.1.4.1.4515.1.9.1.1.1.22 | INTEGER | RO | 20 | |||||||||
column · INTEGER · read-only · current Upper input gain range of the edfa in units of 0.1 db. Example values from LibreNMS test devices
| |||||||||||||
| CedfaGainOutFrom | 1.3.6.1.4.1.4515.1.9.1.1.1.23 | INTEGER | RO | 7 | |||||||||
column · INTEGER · read-only · current Lower output gain range of the edfa in units of 0.1 db. Example values from LibreNMS test devices
| |||||||||||||
| CedfaGainOutTo | 1.3.6.1.4.1.4515.1.9.1.1.1.24 | INTEGER | RO | 21 | |||||||||
column · INTEGER · read-only · current Upper output gain range of the edfa in units of 0.1 db. Example values from LibreNMS test devices
| |||||||||||||
| CedfaPowerInFrom | 1.3.6.1.4.1.4515.1.9.1.1.1.25 | INTEGER | RO | -22 | |||||||||
column · INTEGER · read-only · current Lower input power range of the edfa in units of 0.1 dbm. Example values from LibreNMS test devices
| |||||||||||||
| CedfaPowerInTo | 1.3.6.1.4.1.4515.1.9.1.1.1.26 | INTEGER | RO | 14 | |||||||||
column · INTEGER · read-only · current Upper input power range of the edfa in units of 0.1 dbm. Example values from LibreNMS test devices
| |||||||||||||
| CedfaPowerOutFrom | 1.3.6.1.4.1.4515.1.9.1.1.1.27 | INTEGER | RO | -2 | |||||||||
column · INTEGER · read-only · current Lower output power range of the edfa in units of 0.1 dbm. Example values from LibreNMS test devices
| |||||||||||||
| CedfaPowerOutTo | 1.3.6.1.4.1.4515.1.9.1.1.1.28 | INTEGER | RO | 22 | |||||||||
column · INTEGER · read-only · current Upper output power range of the edfa in units of 0.1 dbm. Example values from LibreNMS test devices
| |||||||||||||
| CedfaFromChannel | 1.3.6.1.4.1.4515.1.9.1.1.1.29 | INTEGER | RO | 15 | |||||||||
column · INTEGER · read-only · current The first channel number supported by the edfa; 0 to ignore. Example values from LibreNMS test devices
| |||||||||||||
| CedfaToChannel | 1.3.6.1.4.1.4515.1.9.1.1.1.30 | INTEGER | RO | 62 | |||||||||
column · INTEGER · read-only · current The last channel number supported by the edfa; 0 to ignore. Example values from LibreNMS test devices
| |||||||||||||
| CedfaOscChannel | 1.3.6.1.4.1.4515.1.9.1.1.1.31 | INTEGER | RO | 1510 | |||||||||
column · INTEGER · read-only · current The wavelenght of the optical supervisory channel e.g. 1510, 1490. Example values from LibreNMS test devices
| |||||||||||||
| CedfaRedBlueType | 1.3.6.1.4.1.4515.1.9.1.1.1.32 | INTEGER | RO | none(3) | |||||||||
column · INTEGER · read-only · current The type of the edaf.
Example values from LibreNMS test devices
| |||||||||||||
| CedfaRole | 1.3.6.1.4.1.4515.1.9.1.1.1.33 | INTEGER | RO | boosterInline(2) | |||||||||
column · INTEGER · read-only · current The role of the edaf.
Example values from LibreNMS test devices
| |||||||||||||
| CedfaFreeDescription | 1.3.6.1.4.1.4515.1.9.1.1.1.34 | DisplayString | RO | 22dBm Output Power 44 Ch. Booster/Inline | |||||||||
column · DisplayString · read-only · current A free text with additional edfa information. Example values from LibreNMS test devices
| |||||||||||||
| CedfaConfigSafetyThreshold | 1.3.6.1.4.1.4515.1.9.1.1.1.35 | INTEGER | RW | -150 | |||||||||
column · INTEGER · read-write · current The Eye Safety threshold level specified in dBm units. The value given in 0.1 dBm units. The range starts with -50.0 dBm. Example values from LibreNMS test devices
| |||||||||||||
| NedfaTraps | 1.3.6.1.4.1.4515.1.9.2 | ||||||||||||
| NedfaTraps0 | 1.3.6.1.4.1.4515.1.9.2.0 | ||||||||||||
| !edfaStatusChange0 | 1.3.6.1.4.1.4515.1.9.2.0.1 | ||||||||||||
notification · current A edfaStatusChange trap is sent when the value of an instance edfaStatus changes. It can be utilized by an NMS to trigger polls. It is defined to support browsers that don't recognize RFC 2576.
| |||||||||||||
| !edfaControlModeChange0 | 1.3.6.1.4.1.4515.1.9.2.0.2 | ||||||||||||
notification · current A edfaControlModeChange trap is sent when the value of an instance edfaOperControlMode when going from APC to AGC (both directions) in automatic mode. It is defined to support browsers that don't recognize RFC 2576.
| |||||||||||||
| !edfaStatusChange | 1.3.6.1.4.1.4515.1.9.2.1 | ||||||||||||
notification · current A edfaStatusChange trap is sent when the value of an instance edfaStatus changes. It can be utilized by an NMS to trigger polls.
| |||||||||||||
| !edfaControlModeChange | 1.3.6.1.4.1.4515.1.9.2.2 | ||||||||||||
notification · current A edfaControlModeChange trap is sent when the value of an instance edfaOperControlMode when going from APC to AGC (both directions) in automatic mode.
| |||||||||||||
Traps / Notifications
- edfaControlModeChange
1.3.6.1.4.1.4515.1.9.2.2 - edfaControlModeChange0
1.3.6.1.4.1.4515.1.9.2.0.2 - edfaStatusChange
1.3.6.1.4.1.4515.1.9.2.1 - edfaStatusChange0
1.3.6.1.4.1.4515.1.9.2.0.1