MIB Browser
Omnitron TC MIB for use with v5.3 iConverter Management Modules
and NetOutlook

Copyright 2017 Omnitron Systems Technology, Inc.
All rights reserved
Organization
Omnitron Systems Technology, Inc.
Root OID
1.3.6.1.4.1.7342.11
Last updated
Objects
3
Source
Show full MIB
snmptranslate -m OMNITRON-TC-MIB -Tp
snmpwalk -v2c -c <community> -m OMNITRON-TC-MIB <host> 1.3.6.1.4.1.7342.11

Imports

SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIBits, Counter64, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION

OID tree

NameOIDTypeAccessStatus
Nomnitron1.3.6.1.4.1.7342
NicAgent1.3.6.1.4.1.7342.1
IostOmnitronTcMib1.3.6.1.4.1.7342.11

Textual conventions

OstAccessibiltyType INTEGER

deny(1) permit(2)

Accessibilty type enumeration.

deny(1)       Access to the module is not allowed
permit(2)     Access to the module is allowed
OstClassOfService Unsigned32 (0..4)

Display hint: d

Class of service setting.  0=discard, 1=lowest class, 4=highest class
OstClockFreq Unsigned32

Display hint: d-2

Clock frequency in hundreths of MHz.
OstCosL2cpDstAddr Unsigned32 (1..20)

Display hint: d

L2CP destination address enumeration.

Index | Destination Address | Name
------+---------------------+----------
    1 | 01-80-C2-00-00-00   | RSTP
    2 | 01-80-C2-00-00-01   | Pause
    3 | 01-80-C2-00-00-02   | LACP
    4 | 01-80-C2-00-00-02   | Marker
    5 | 01-80-C2-00-00-02   | Link OAM
    6 | 01-80-C2-00-00-02   |
    7 | 01-80-C2-00-00-03   | 802.1x
    8 | 01-80-C2-00-00-04   | IEEE MAC
    9 | 01-80-C2-00-00-05   |
   10 | 01-80-C2-00-00-06   |
   11 | 01-80-C2-00-00-07   | E-LMI
   12 | 01-80-C2-00-00-08   | Pr Bridge
   13 | 01-80-C2-00-00-09   |
   14 | 01-80-C2-00-00-0A   |
   15 | 01-80-C2-00-00-0B   |
   16 | 01-80-C2-00-00-0C   |
   17 | 01-80-C2-00-00-0D   | GVRP
   18 | 01-80-C2-00-00-0E   | LLDP
   19 | 01-80-C2-00-00-0F   |
   20 | 01-80-C2-00-00-20   | GARP
OstCosNameString OCTET STRING (SIZE (1..45))

Display hint: 255a

A class of service name.
OstCosNameStringOrNone OCTET STRING (SIZE (0..45))

Display hint: 255a

A class of service name or an empty string.
OstCosTrustType INTEGER

cosGreenYellow(5) cosTrust(1) cosUseClass(3) cosUsePri(2) cosUsePriClass(4)

CoS trust type enumeration.

Green traffic is marked with low drop precedence and yellow
traffic is marked with high drop precedence.

cosTrust(1)        Trust frame. The frames priority
                   determines the egress class.

cosUsePri(2)       Use the priority ostCosPriority for the
                   frame. The frame will egress with ostCosPriority
                   priority and ostCosPrirority determines the
                   egress class.

cosUseClass(3)     Use the class ostCosClass for the frame.
                   The frame will egress with the frames
                   priority and the ostCosClass egress class.

cosUsePriClass(4)  Use the priority ostCosPriority and class
                   ostCosClass for the frame. The frames will
                   egress with ostCosPri and ostCosClass egress
                   class.

cosGreenYellow(5)  Use ostCosGreenPriority and ostCosGreenClass for
                   green traffic. Use ostCosYellowPriority and
                   ostCosYellowClass for yellow traffic.
OstEgressQueueIndexType Unsigned32 (1..8)

Display hint: d

A value that uniquely identifies an Egress Queue.

The valid values are 1 to X, where X is the maximum supported profile.
The maximum value for X for the GM4 is 4.
OstEgressSchedulingProfileIndexType Unsigned32 (1..8)

Display hint: d

A value that uniquely identifies an Egress Scheduling Profile.

The valid values are 1 to X, where X is the maximum supported profile.
The maximum value for X for the GM4 is 4.
OstElpsProtectType INTEGER

e1plus1BiAps(3) e1plus1UniAps(2) e1plus1UniNoAps(1) e1to1(4) notAvailable(5)

A value that represents the ELPS protection type.  The value can be one
of the following:

e1plus1UniNoAps(1)   1+1 unidirectional without APS communication
e1plus1UniAps(2)     1+1 unidirectional switching with APS communication
e1plus1BiAps(3)      1+1 bidirectional w/APS communication
e1to1(4)             1:1 bidirectional w/APS communication
notAvailable(5)      Protect Type is unknown or not available, value returned
                         for status read, not allowed to write
OstElpsRequestStates INTEGER

doNotRevert(1) exercise(4) forcedSwitch(13) lockoutProtection(15) manualSwitch(7) manualSwitchWorking(6) noRequest(0) notAvailable(16) revertRequest(2) signalDegrade(9) signalFailProtection(14) signalFailWorking(11) waitToRestore(5)

A value that represents the current request/state of either the local or
remote (partner) ELPS instance.  The value can be one of the following:

noRequest(0)             No Request (NR), lowest priority
doNotRevert(1)           Do Not Revert (DNR)
revertRequest(2)         Revert request (RR)
exercise(4)              Exercise APS protocol (EXER)
waitToRestore(5)         Wait to restore (WTR)
manualSwitchWorking(6)   Manual swtich to working (MS-W)
manualSwitch(7)          Manual switch (MS)
signalDegrade(9)         Signal degrade (SD)
signalFailWorking(11)    Signal fail for working (SF)
forcedSwitch(13)         Forced switch (FS)
signalFailProtection(14) Signal fail for protection (SF-P)
lockoutProtection(15)    Lock of protection (LO), highest priority
notAvailable(16)         Status is unknown or not available, value returned
                         for status read, not allowed to write
OstElpsSignalStates INTEGER

normalSignal(1) notAvailable(2) nullSignal(0)

A value that represents the requested or bridged signal for either
the local or remote (partner) ELPS instance.  The value can be one of
the following:

nullSignal(0)            Null signal. This indicates the signal that
                         the near-end requests be carried over the
                         protection path
normalSignal(1)          Normal traffic signal. This indicates the
                         signal that is bridged onto the protection
                         path.
notAvailable(2)          Protect Type is unknown or not available, value
                         returned for status read, not allowed to write
OstErpsLinkState INTEGER

down(2) na(0) up(1)

A value that represents the current port link state. This is a
function that indicates whether the current port is linked.
The value can be one of the following:

na(0)                    Not Applicable, port state is unknown
up(1)                    Port is linked and capable of passing traffic
down(2)                  Port is not linked and is not capable of
                         passing traffic
OstErpsPortState INTEGER

blocked(2) forward(1) na(0)

A value that represents the current forwarding state of the port.
The value can be one of the following:

na(0)                    Not Applicable, port state is unknown
forward(1)               Port is in the forwarding state
blocked(2)               Port is in the blocked state
OstErpsPortType INTEGER

rp0(1) rp1(2)

A value that represents the Ring Port type. The value can be one of the
following:

rp0(1)                   Ring Port 0
rp1(2)                   Ring Port 1
OstErpsRingStates INTEGER

clear(14) forcedSwtich(13) localClearSignalFail(10) localSignalFail(11) manualSwitch(7) noRequest(0) rapsForcedSwitch(12) rapsManualSwitch(8) rapsNr(1) rapsNrRb(2) rapsSignalFail(9) wtbExpires(4) wtbRunning(3) wtrExpires(6) wtrRunning(5)

A value that represents the current request/state of either the local or
remote (partner) ERPS instance.  The value can be one of the following:

noRequest(0)             No Request (NR), local, lowest priority
rapsNr(1)                Ring APS (R-APS) No Request (NR), remote
rapsNrRb(2)              Ring APS (R-APS) No Request (NR), RPL Blocked (RB), remote
wtbRunning(3)            Wait to Block (WTB) running, local
wtbExpires(4)            Wait to Block (WTB) expires, local
wtrRunning(5)            Wait to Restore (WTR) running, local
wtrExpires(6)            Wait to Restore (WTR) expires, local
manualSwitch(7)          Manual Switch (MS), local
rapsManualSwitch(8)      Ring APS (R-APS) Manual Switch (MS), remote
rapsSignalFail(9)        Ring APS (R-APS) Signal Fail (SF), remote
localClearSignalFail(10) Local clear Signal Fail (SF), local
localSignalFail(11)      Local Signal Fail (SF), local
rapsForcedSwitch(12)     Ring APS (R-APS) Forced Switch (FS), remote
forcedSwtich(13)         Forced Switch (FS), local
clear(14)                Clear, local
OstErpsRingStatus INTEGER

forcedSwitch(5) idle(2) initializing(1) manualSwitch(4) pending(6) protection(3)

A value that represents the current ring status. This is state machine node
state value for the ERPS instance.  The value can be one of the
following:

initializing(1)          State machine initialization
idle(2)                  Idle State (A)
protection(3)            Protection (B)
manualSwitch(4)          Manual Switch (C)
forcedSwitch(5)          Forced Switch (D)
pending(6)               Pending (E)
OstErrorString OCTET STRING (SIZE (0..255))

Display hint: 255a

The SNMP error string for further definition of a SNMP error.
OstEvcNameString OCTET STRING (SIZE (1..45))

Display hint: 255a

An EVC name.
OstEvcNameStringOrNone OCTET STRING (SIZE (0..45))

Display hint: 255a

An EVC name or an empty string.
OstFileNameString OCTET STRING (SIZE (1..45))

Display hint: 255a

A internal file name.
OstFileNameStringOrNone OCTET STRING (SIZE (0..45))

Display hint: 255a

A internal file name.
OstFingerprintString OCTET STRING (SIZE (1..64))

Display hint: 255a

The fingerprint value for SSH protocol.
OstFloatValue OCTET STRING (SIZE (0..20))

Display hint: 255a

Floating point data type as represented in an octet string.
Legal values and precision are indicated by the appropriate object.
Only numbers and the decimal place are legal digit values.

Example values:
   1000
   1500.05
   1545.25
OstFrameCount64 Counter64

Display hint: d

Frame counter value.
OstFrameSizeList OCTET STRING (SIZE (1..255))

Display hint: 255a

Denotes a list of one or more frame sizes.

1. Frame sizes have a value from 64 to 10240 bytes for the GM3, GM4,
   and GM4-PoE. Frame sizes have a value from 64 to 10240 bytes for
   the XM5.

2. Individual frame sizes are included when separated by a comma ','.

3. A range of frame sizes is included when separated by '..'.

4. A range of sizes ending in a colon and a value, i.e. start..end:value,
   is the frame increment size for the next iteration (min value is 4)

5. Ranges must be organized min size to max size, i.e. min..max

6. Individual sizes can be mixed in any order

Example values:
  64
  64..1024:64
  64,128,256,512,1024,1280,1518,10000
OstIndexIntegerNextFree Unsigned32 (0..16)

Display hint: d

An integer which may be used as a new index in a table. The special value of 0 indicates that no more new entries can be created in the relevant table. When a MIB is used for configuration, an object with this SYNTAX always contains a legal value (if non-zero) for an index that is not currently used in the relevant table. The Command Generator (Network Management Application) reads this variable and uses the (non-zero) value read when creating a new row with an SNMP SET. When the SET is performed, the Command Responder (agent) MUST determine whether the value is indeed still unused; Two Network Management Applications may attempt to create a row (configuration entry) simultaneously and use the same value. If it is currently unused, the SET succeeds and the Command Responder (agent) changes the value of this object, according to an implementation-specific algorithm. If the value is in use, however, the SET fails. The Network Management Application MUST then re-read this variable to obtain a new usable value. An OBJECT-TYPE definition using this SYNTAX MUST specify the relevant table for which the object is providing this functionality. 
OstIpAddr OCTET STRING (SIZE (0..39))

Display hint: 255a

This data type is used to model both IPv4 and IPv6 addresses. It
is a hexadecimcal octet string with separators between number groups:
either '.' for IPv4 or ':' for IPv6. The IP type is derived based upon
the format of the string. Valid IP addreses:
    '192.168.1.220'
    'fe80:0000:0:0:1234:5678:abcd:efff'
OstIpPriorityList OCTET STRING (SIZE (0..64))

Display hint: 255a

Selects IP priority values.  Valid values are from 0 to 63.
Format:
    X       selects a single PCP priority value
    X..Y    selects a range of PCP priority values, X to Y
    X,Y     selects PCP priority values seperated by a comma
Example values:
 0
 2..5
 0,2..5
OstIpv6Addr OCTET STRING (SIZE (16))

Display hint: 2x:2x:2x:2x:2x:2x:2x:2x

This data type is used to model the IPv6 address. This is a
binary string of up to 8 octets in network byte-order.
OstMhfCreation INTEGER

ostMHFdefault(1) ostMHFexplicit(2)

Indicates if the Management Entity can create MHFs.

The valid values are:
        ostMHFdefault(2) MHFs can be created on this VID on any
                Bridge port through which this VID can pass.
        ostMHFexplicit(3) MHFs can be created for this VID only on
                Bridge ports through which this VID can
                pass, and only if a MEP is created at some
                lower MD Level.
OstMipdMethodOfCreation INTEGER

ostExplicit(1) ostExplicitImplicitMa(4) ostImplicitMa(2) ostImplicitMde(3)

Indicates the method of how this Mip table entry was created
The valid values are:
        ostExplicit(1) indicates the Mip was created explicitly
                through a command.
        ostImplicitMa(2) indicates the Mip was created implicitly
                through the MA command.
        ostImplicitMde(3) indicates the Mip was created implicitly
                through the CFM default Md table.
        ostExplicitImplicitMa(4) indicates the Mip was created both
                implicitly and explicitly through the MA command.
OstModeType INTEGER

ap(2) normal(1) sp(3)

The module Mode Type as AP, SP or neither.

normal(1)   Not specifically AP or SP
ap(2)       Access Provider
sp(3)       Service Provider
OstModuleSingleIndex Unsigned32 (101..9999)

Display hint: d

A value that uniquely identifies the chassis and slot in which the module is located.
Base 10 Format: CCSS where
     CC is the chassis index, 1 to 99
     SS is the slot index, 1 to 99
OstPcpPriorityList OCTET STRING (SIZE (0..64))

Display hint: 255a

Selects PCP priority values.  Valid values are from 0 to 7.
Format:
    X       selects a single PCP priority value
    X..Y    selects a range of PCP priority values, X to Y
    X,Y     selects PCP priority values seperated by a comma
Example values:
 0
 2..5
 0,2..5
OstPortClockType INTEGER

adaptiveAcqu(2) adaptiveIdle(1) adaptiveTrk1(3) adaptiveTrk2(4) coax(6) holdOver(5) internal(7) line(8)

A value that indicates the TDM port recovery state/mode.
OstPortList OCTET STRING

Display hint: 255a

Denotes a list of one or more ports, separated by comma characters, in the
form of an ASCII string, which is case insensitive.

Port  Description
----  ------------------
 1    Port 1
 2    Port 2
 3    Port 3
 4    Port 4
 5    Port 5
 6    Port 6
 7    Port 7
 8    Port 8
 9    Port 9
 10   Port 10
 11   Port 11
 12   Port 12
 13   Port 13
 14   Port 14
 15   Port 15
 16   Port 16
 17   Port 17
 a    backplane port A
 b    backplane port B
 mgt1 management port 1
 mgt2 management port 2
 all  includes all ports

Example: '1,2,a,mgt1'
OstPortNumber Unsigned32 (0..99)

Display hint: d

This object selects the port number for the specific test
instance that is configured.

This value is dependent upon actual product accessed. The port number
for a specific port can be determined by selecting the module type
and then the port that is accessed. A value of '0' indicates that
no port is defined.

Module Type        P1   P2   P3   P4   P5   BP A  BP B  Mgt1  Mgt2
-----------------  ---  ---  ---  ---  ---  ----  ----  ----  ----
3-port plug-in     1    2    3    n/a  n/a  4     5     6     7
3-port standalone  1    2    3    n/a  n/a  n/a   n/a   6     7
2-port plug-in     1    2    n/a  n/a  n/a  3     4     5     6
2-port standalone  1    2    n/a  n/a  n/a  n/a   n/a   5     6
4-port             1    2    3    4    n/a  5     6     n/a   n/a
5-port             1    2    3    4    5    n/a   n/a   6     7

For the 7 port module: Port 1 - Port 7 are ports 1 - 7 are the front
facing ports, port 8 is the dedicated management port, port 9 is Mgt1
and port 10 is Mgt2.

For the 16 port module: Port 1 - Port 16 are the customer facing
ports, port 17 is the dedicated management port, port 18 is Mgt1 and
port 19 is Mgt2.

Other values are undefined.
OstPortSingleIndex Unsigned32 (10101..999999)

Display hint: d

A value that uniquely identifies a module port, and the chassis and slot in
which the module is located.
Base 10 Format: CCSSPP where
     CC is the chassis index, 1 to 99
     SS is the slot index, 1 to 99
     PP is the port index, 1 to 99
OstPriority Unsigned32 (0..7)

Display hint: d

Priority setting.
OstProbeNameString OCTET STRING (SIZE (1..45))

Display hint: 255a

An EVC name.
OstProfileNameString OCTET STRING (SIZE (1..45))

Display hint: 255a

A test profile name.
OstTestResultType INTEGER

fail(2) oversubscribe(3) pass(1)

A value that indicates the result of a test.  The value can be one of
the following:

pass(1)              Indicates the test has passed successfully
fail(2)              Indicates the test has failed
oversubscribe(3)     Indicates the test failed due to oversubscription
                     of a resource
OstTestStatusType INTEGER

testCompleted(4) testInProcess(2) testInitializing(5) testNotStarted(1) testStopped(3)

A value that indicates the status of the current test instance.  The
value can be one of the following:

testNotStarted(1)    Current test instance has not started yet,
                     not fully configured, or waiting for loop-up
testInProcess(2)     Current test instance is currently running
testStopped(3)       Current test instance has been stopped after running
                     for a period of time
testCompleted(4)     Current test instance has completed
testInitializing(5)  Current test is the process of starting, used to
                     restart a test in process, completed, or stopped
OstUnsigned64 Counter64

Display hint: d

A non-negative 64-bit bit integer, without counter semantics, between 0
and 2^64-1 inclusive (0 to 18446744073709551615 decimal).

It can have a MAX-ACCESS of read-only or read-write.

SYNTAX is Counter64 for the encoding rules only.
OstUserNameString OCTET STRING (SIZE (1..32))

Display hint: 255a

A string that is used to identify a specific user.
OstVlanId Integer32 (0..4095)

Display hint: d

The VLAN-ID that uniquely identifies a VLAN.  This
is the 12-bit VLAN-ID used in the VLAN Tag header.
OstVlanIdList OCTET STRING (SIZE (0..110))

Display hint: 255a

Denotes a list of one or more VLAN IDs.
VLAN IDs have a value of 0 to 4095.
Individual VLAN IDs are included when separated by a comma ','.
A range of VLAN IDs is included when separated by '..'.
An asterisk indicates untagged data.
'rest' selects remaining VLAN IDs.
'all' selects all VLAN IDs.
Example values:
  100,110
  100..110
  100,110,200..210
  100,110,200..210,500..510

Used by