MIB Browser
Textual conventions for NBS mibs.

Some informal NBS conventions used include the following:

  A DESCRIPTION specifying 'Persistent' indicates a user-
  configured attribute that can be stored in the Agent's
  non-volatile file system as a configuration file such as
  'startup-config'.

  A DESCRIPTION specifying 'Impulse' indicates a user setting
  that the Agent will immediately attempt but will not store
  persistently.

  An object name containing 'Admin' indicates a setting
  requested by the user which may be overridden by the system.
  Admin objects should be updated in the Agent immediately, so
  a GET request immediately after the SET is accepted will
  be answered with a GET-RESPONSE indicating the new value.

  An object name containing 'Oper' indicates an attribute's
  actual state.

  An object name containing 'Caps' is a bitmask which refers to
  the capabilities of an entity to support corresponding entries
  in a specified feature table.
Organization
NBS
Root OID
1.3.6.1.4.1.629.250
Last updated
Objects
2
Source
Show full MIB
snmptranslate -m NBS-MIB -Tp
snmpwalk -v2c -c <community> -m NBS-MIB <host> 1.3.6.1.4.1.629.250

Imports

SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIBits, Counter64, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION

OID tree

NameOIDTypeAccessStatus
Nnbs1.3.6.1.4.1.629
InbsMib1.3.6.1.4.1.629.250

Textual conventions

NbsTcMHz Unsigned32 (1..4294967295)
Frequency in units of MHz.  When writable, persistent.
Not supported value: 0
NbsTcMicroAmp INTEGER (-1..2147483647)
Electrical current in units of micro amperes. When writable, persistent.
Not supported value: -1
NbsTcMilliAmp INTEGER (-1..1000000)
Amperage in units of milliAmps.  When writable, persistent.
Not supported value: -1
NbsTcMilliDb INTEGER (-2147483648..100000)
Decibels in thousandths.  When writable, persistent.

The reserved value -1,000,000 indicates that the signal is
blocked from passing through.

Blocked value:       -1000000
Not supported value: 0x80000000
(decimal -2147483648)
NbsTcMilliVolt INTEGER (-1..1000000)
Voltage in units of milliVolts.  When writable, persistent.
Not supported value: -1
NbsTcMilliWatts INTEGER
Electrical Power, in milliwatts.

Not supported value: -1
NbsTcPartIndex Unsigned32
Unique ID within scope of an ifIndex
NbsTcStagingCommit INTEGER

apply(4) notSupported(1) revertToCommitted(3) supported(2)

Staging commit command
NbsTcStatusLevel INTEGER

notSupported(1) statusGood(4) statusHighError(6) statusHighWarning(5) statusLowError(2) statusLowWarning(3)

Severity level
NbsTcStatusSimple INTEGER

bad(2) good(3) notInstalled(4) notSupported(1)

Basic operating status
NbsTcTemperature INTEGER (-2147483648..1000)
Temperature in degrees Celsius.  When writable, persistent.
Not supported value: 0x80000000
(decimal -2147483648)
Unsigned16TC Unsigned32 (0..65535)
Used to represent an unsigned two-octet integer
Unsigned64TC Counter64
Used to represent an unsigned eight-octet integer
WritableU64 OCTET STRING (SIZE (8))
Used to represent an unsigned eight-octet integer which can
be SET in SNMPv1

Used by