MIB Browser
The MIB module defines Moxa PoE
Organization
Moxa Inc.
Root OID
1.3.6.1.4.1.8691.608
Last updated
Objects
70
Source
Show full MIB
snmptranslate -m MOXA-POE-BT-MIB -Tp
snmpwalk -v2c -c <community> -m MOXA-POE-BT-MIB <host> 1.3.6.1.4.1.8691.608

Imports

SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso
SNMPv2-TCDisplayString, PhysAddress, RowStatus, TEXTUAL-CONVENTION, TruthValue

OID tree

NameOIDTypeAccessStatusExample
Nmoxa1.3.6.1.4.1.8691
Ipoe1.3.6.1.4.1.8691.608
NmxPoeBt1.3.6.1.4.1.8691.608.2
NpoeBtNotification1.3.6.1.4.1.8691.608.2.0
!poeBtNotifyPdPowerOn1.3.6.1.4.1.8691.608.2.0.1
!poeBtNotifyPdPowerOff1.3.6.1.4.1.8691.608.2.0.2
!poeBtNotifyLowInputVoltage1.3.6.1.4.1.8691.608.2.0.3
!poeBtNotifyPdOverCurrent1.3.6.1.4.1.8691.608.2.0.4
!poeBtNotifyPdNoResponse1.3.6.1.4.1.8691.608.2.0.5
!poeBtNotifyOverBudgetLimit1.3.6.1.4.1.8691.608.2.0.6
!poeBtNotifyPdDetectionFailure1.3.6.1.4.1.8691.608.2.0.7
!poeBtNotifyNonPdOrPdShortCircuit1.3.6.1.4.1.8691.608.2.0.8
NpoeBtConfiguration1.3.6.1.4.1.8691.608.2.1
NpoeBtConfigGeneral1.3.6.1.4.1.8691.608.2.1.1
SpoeBtConfigPowerOutput1.3.6.1.4.1.8691.608.2.1.1.1TruthValueRW
SpoeBtConfigAutoPowerCutting1.3.6.1.4.1.8691.608.2.1.1.2TruthValueRW
SpoeBtConfigSystemPowerBudget1.3.6.1.4.1.8691.608.2.1.1.3Integer32 (30..300)RW
TpoeBtConfigPortTable1.3.6.1.4.1.8691.608.2.1.1.4NA
RpoeBtConfigPortEntry1.3.6.1.4.1.8691.608.2.1.1.4.1NA
CpoeBtConfigPortIndex1.3.6.1.4.1.8691.608.2.1.1.4.1.1INTEGERRO
CpoeBtConfigPortPowerOutput1.3.6.1.4.1.8691.608.2.1.1.4.1.2TruthValueRW
CpoeBtConfigOutputMode1.3.6.1.4.1.8691.608.2.1.1.4.1.3INTEGERRW
CpoeBtConfigPowerAllocation1.3.6.1.4.1.8691.608.2.1.1.4.1.4Integer32 (0..90)RW
CpoeBtConfigLegacyPdDetection1.3.6.1.4.1.8691.608.2.1.1.4.1.5TruthValueRW
CpoeBtConfigPriority1.3.6.1.4.1.8691.608.2.1.1.4.1.6INTEGERRW
SpoeBtConfigPowerManagementMode1.3.6.1.4.1.8691.608.2.1.1.5INTEGERRW
NpoeBtConfigFailureCheck1.3.6.1.4.1.8691.608.2.1.2
TpoeBtConfigFcPortTable1.3.6.1.4.1.8691.608.2.1.2.1NA
RpoeBtConfigFcPortEntry1.3.6.1.4.1.8691.608.2.1.2.1.1NA
CpoeBtConfigFcPortIndex1.3.6.1.4.1.8691.608.2.1.2.1.1.1INTEGERRO
CpoeBtConfigFcEnable1.3.6.1.4.1.8691.608.2.1.2.1.1.2TruthValueRW
CpoeBtConfigFcDeviceIp1.3.6.1.4.1.8691.608.2.1.2.1.1.3IpAddressRW
CpoeBtConfigFcNoResponseTimes1.3.6.1.4.1.8691.608.2.1.2.1.1.4Integer32 (1..10)RW
CpoeBtConfigFcCheckFrequency1.3.6.1.4.1.8691.608.2.1.2.1.1.5Integer32 (5..300)RW
CpoeBtConfigFcAction1.3.6.1.4.1.8691.608.2.1.2.1.1.6INTEGERRW
NpoeBtConfigScheduling1.3.6.1.4.1.8691.608.2.1.3
TpoeBtConfigScheRuleTable1.3.6.1.4.1.8691.608.2.1.3.1NA
RpoeBtConfigScheRuleEntry1.3.6.1.4.1.8691.608.2.1.3.1.1NA
CpoeBtConfigRuleIndex1.3.6.1.4.1.8691.608.2.1.3.1.1.1INTEGERRO
CpoeBtConfigScheName1.3.6.1.4.1.8691.608.2.1.3.1.1.2DisplayString (SIZE (0..63))RC
CpoeBtConfigScheEnable1.3.6.1.4.1.8691.608.2.1.3.1.1.3TruthValueRC
CpoeBtConfigScheStartDateYear1.3.6.1.4.1.8691.608.2.1.3.1.1.4Integer32 (1970..2038)RC
CpoeBtConfigScheStartDateMonth1.3.6.1.4.1.8691.608.2.1.3.1.1.5Integer32 (1..12)RC
CpoeBtConfigScheStartDateDay1.3.6.1.4.1.8691.608.2.1.3.1.1.6Integer32 (1..31)RC
CpoeBtConfigScheStartTimeHour1.3.6.1.4.1.8691.608.2.1.3.1.1.7Integer32 (0..24)RC
CpoeBtConfigScheStartTimeMin1.3.6.1.4.1.8691.608.2.1.3.1.1.8Integer32 (0..59)RC
CpoeBtConfigScheEndTimeHour1.3.6.1.4.1.8691.608.2.1.3.1.1.9Integer32 (0..24)RC
CpoeBtConfigScheEndTimeMin1.3.6.1.4.1.8691.608.2.1.3.1.1.10Integer32 (0..59)RC
CpoeBtConfigScheRepeatOn1.3.6.1.4.1.8691.608.2.1.3.1.1.11OCTET STRINGRC
CpoeBtConfigScheAppliedPorts1.3.6.1.4.1.8691.608.2.1.3.1.1.12OCTET STRINGRC
CpoeBtConfigScheRowStatus1.3.6.1.4.1.8691.608.2.1.3.1.1.13RowStatusRC
NpoeBtStatus1.3.6.1.4.1.8691.608.2.2
NpoeBtStatMonitor1.3.6.1.4.1.8691.608.2.2.1
SpoeBtStatMaxInputPower1.3.6.1.4.1.8691.608.2.2.1.1Integer32RO
SpoeBtStatActualPower1.3.6.1.4.1.8691.608.2.2.1.2Integer32RO
SpoeBtStatBudgetLimit1.3.6.1.4.1.8691.608.2.2.1.3Integer32RO150
SpoeBtStatConsumedPower1.3.6.1.4.1.8691.608.2.2.1.4Integer32RO0
SpoeBtStatRemainingAvailablePower1.3.6.1.4.1.8691.608.2.2.1.5Integer32RO
TpoeBtStatPortTable1.3.6.1.4.1.8691.608.2.2.1.6NA
RpoeBtStatPortEntry1.3.6.1.4.1.8691.608.2.2.1.6.1NA
CpoeBtStatPortIndex1.3.6.1.4.1.8691.608.2.2.1.6.1.1INTEGERRO
CpoeBtStatPowerOutput1.3.6.1.4.1.8691.608.2.2.1.6.1.2TruthValueRO1
CpoeBtStatClassification1.3.6.1.4.1.8691.608.2.2.1.6.1.3OCTET STRINGRO55:6e:6b:6e:6f:77:6e:00:00:00:00:00:00:00:00:00…
CpoeBtStatCurrent1.3.6.1.4.1.8691.608.2.2.1.6.1.4DisplayStringRO5.12
CpoeBtStatVoltage1.3.6.1.4.1.8691.608.2.2.1.6.1.5DisplayStringRO41.20
CpoeBtStatConsumption1.3.6.1.4.1.8691.608.2.2.1.6.1.6DisplayStringRO10.00
CpoeBtStatDeviceType1.3.6.1.4.1.8691.608.2.2.1.6.1.7INTEGERROdot3af(2)
CpoeBtStatConfigSuggestion1.3.6.1.4.1.8691.608.2.2.1.6.1.8INTEGERROnoSuggestion(0)
CpoeBtStatPdFailureCheckStatus1.3.6.1.4.1.8691.608.2.2.1.6.1.9INTEGERROalive(1)
SpoeBtStatAllocatedPower1.3.6.1.4.1.8691.608.2.2.1.7INTEGERRO131

Traps / Notifications