MOXA-FIBER-CHECK-MIB
Moxa Technologies Co., Ltd.The MIB module defines Moxa Fiber Check
snmptranslate -m MOXA-FIBER-CHECK-MIB -Tpsnmpwalk -v2c -c <community> -m MOXA-FIBER-CHECK-MIB <host> 1.3.6.1.4.1.8691.603.5.3Imports
| MOXA-SWITCHING-MIB | layer2Diagnosic |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, RowStatus, TEXTUAL-CONVENTION, TruthValue |
OID tree
| Name | OID | Type | Access | Status | Example |
|---|---|---|---|---|---|
| ImxFiberCheck | 1.3.6.1.4.1.8691.603.5.3 | ||||
identity The MIB module defines Moxa Fiber Check | |||||
| NfiberCheckNotification | 1.3.6.1.4.1.8691.603.5.3.0 | ||||
| !fiberCheckNotifyFiberCheckWarning | 1.3.6.1.4.1.8691.603.5.3.0.1 | ||||
| NfiberCheckConfiguration | 1.3.6.1.4.1.8691.603.5.3.1 | ||||
| NfiberCheckConfigGeneral | 1.3.6.1.4.1.8691.603.5.3.1.1 | ||||
| TfiberCheckConfigPortTable | 1.3.6.1.4.1.8691.603.5.3.1.1.1 | NA | |||
table · not-accessible · current The Fiber Check table of general config function. | |||||
| RfiberCheckConfigPortEntry | 1.3.6.1.4.1.8691.603.5.3.1.1.1.1 | NA | |||
row · not-accessible · current The Fiber Check table entry of general config function. | |||||
| CfiberCheckConfigPortIndex | 1.3.6.1.4.1.8691.603.5.3.1.1.1.1.1 | INTEGER | RO | ||
column · INTEGER · read-only · current The fiber index of config function. | |||||
| CfiberCheckConfigMode | 1.3.6.1.4.1.8691.603.5.3.1.1.1.1.2 | INTEGER | RW | ||
column · INTEGER · read-write · current Users configure mode to define threshold by user.
| |||||
| CfiberCheckConfigTemperatureWarnC | 1.3.6.1.4.1.8691.603.5.3.1.1.1.1.3 | DisplayString | RW | ||
column · DisplayString · read-write · current Users configure the high warning value of fiber temperature (Celsius) to determine which value issue the fiber check warning. | |||||
| CfiberCheckConfigTemperatureWarnF | 1.3.6.1.4.1.8691.603.5.3.1.1.1.1.4 | DisplayString | RW | ||
column · DisplayString · read-write · current Users configure the high warning value of fiber temperature (Fahrenheit) to determine which value issue the fiber check warning. | |||||
| CfiberCheckConfigTxPowerWarnHigh | 1.3.6.1.4.1.8691.603.5.3.1.1.1.1.5 | DisplayString | RW | ||
column · DisplayString · read-write · current Users configure the high warning value of fiber tx power to determine which value issue the fiber check warning. | |||||
| CfiberCheckConfigTxPowerWarnLow | 1.3.6.1.4.1.8691.603.5.3.1.1.1.1.6 | DisplayString | RW | ||
column · DisplayString · read-write · current Users configure the low warning value of fiber tx power to determine which value issue the fiber check warning. | |||||
| CfiberCheckConfigRxPowerWarnHigh | 1.3.6.1.4.1.8691.603.5.3.1.1.1.1.7 | DisplayString | RW | ||
column · DisplayString · read-write · current Users configure the high warning value of fiber rx power to determine which value issue the fiber check warning. | |||||
| CfiberCheckConfigRxPowerWarnLow | 1.3.6.1.4.1.8691.603.5.3.1.1.1.1.8 | DisplayString | RW | ||
column · DisplayString · read-write · current Users configure the low warning value of fiber rx power to determine which value issue the fiber check warning. | |||||
| CfiberCheckConfigResetToDefault | 1.3.6.1.4.1.8691.603.5.3.1.1.1.1.9 | TruthValue | RW | ||
column · TruthValue · read-write · current Writing true(1) to this object forces the system to reset this port's fiber check configuration to default. Any other operation on this object has no effect and it always returns false(2) when read. | |||||
| NfiberCheckStatus | 1.3.6.1.4.1.8691.603.5.3.2 | ||||
| NfiberCheckStatMonitor | 1.3.6.1.4.1.8691.603.5.3.2.1 | ||||
| TfiberCheckStatPortTable | 1.3.6.1.4.1.8691.603.5.3.2.1.1 | NA | |||
table · not-accessible · current The fiber check table. | |||||
| RfiberCheckStatPortEntry | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1 | NA | |||
| CfiberCheckStatPortIndex | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1.1 | INTEGER | RO | ||
column · INTEGER · read-only · current The port index fiber module. | |||||
| CfiberCheckStatModelName | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1.2 | DisplayString | RO | SFP-1G10ALC | |
| CfiberCheckStatSN | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1.3 | DisplayString | RO | VE2327001347 | |
| CfiberCheckStatWaveLength | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1.4 | INTEGER | RO | 1310 | |
| CfiberCheckStatTemperatureC | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1.5 | DisplayString | RO | 49.82 | |
| CfiberCheckStatTemperatureF | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1.6 | DisplayString | RO | 121.68 | |
| CfiberCheckStatVoltage | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1.7 | DisplayString | RO | 3.25 | |
| CfiberCheckStatTxPower | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1.8 | DisplayString | RO | -6.15 | |
| CfiberCheckStatRxPower | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1.9 | DisplayString | RO | -8.93 | |
| CfiberCheckStatTemperatureLimitC | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1.10 | DisplayString | RO | 100.00 | |
| CfiberCheckStatTemperatureLimitF | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1.11 | DisplayString | RO | 212.00 | |
| CfiberCheckStatTxPowerLimit | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1.12 | DisplayString | RO | [-12.00, 0.00] | |
| CfiberCheckStatRxPowerLimit | 1.3.6.1.4.1.8691.603.5.3.2.1.1.1.13 | DisplayString | RO | [-21.00, -2.00] | |
Traps / Notifications
- fiberCheckNotifyFiberCheckWarning
1.3.6.1.4.1.8691.603.5.3.0.1