G6-POE-MIB
MICROSENS GmbH & Co. KGMicrosens private MIB for Generation 6 Ethernet Switches
snmptranslate -m G6-POE-MIB -Tpsnmpwalk -v2c -c <community> -m G6-POE-MIB <host> 1.3.6.1.4.1.3181.10.6.1Imports
| MICROSENS-G6-MIB | g6 |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Counter32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, MacAddress, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Idevice | 1.3.6.1.4.1.3181.10.6.1 | ||||||||||||||||||||
identity Microsens private MIB for Generation 6 Ethernet Switches | |||||||||||||||||||||
| Npoe | 1.3.6.1.4.1.3181.10.6.1.33 | ||||||||||||||||||||
| SpoePoeMaxPowerAvailable | 1.3.6.1.4.1.3181.10.6.1.33.1 | Integer32 (0..65535) | RW | ||||||||||||||||||
scalar · Integer32 (0..65535) · read-write · current Defines the total power that this units power supply can support. This value is used to balance the PoE output power delivered. Please adjust according to connected power supply rating. | |||||||||||||||||||||
| SpoeRestartPoePort | 1.3.6.1.4.1.3181.10.6.1.33.2 | DisplayString | RW | ||||||||||||||||||
scalar · DisplayString · read-write · current This function may be used to briefly drop the power on a PoE port in order to reboot the attached device. Please supply port number as parameter. The shorthand port format like 1 for 1/1 may be used. Syntax examples: poe.restart_poe_port = 1/2,1/5 or poe.restart_poe_port = 1-3 or equivalent poe.restart_poe_port = 1/1-1/3. | |||||||||||||||||||||
| SpoeRestartEnergyPort | 1.3.6.1.4.1.3181.10.6.1.33.3 | DisplayString | RW | ||||||||||||||||||
scalar · DisplayString · read-write · current This function may be used to restart measurement of energy consumption per port. Please supply port number as parameter. The shorthand port format like 1 for 1/1 may be used. Syntax examples: poe.restart_energy_port = 1/2,1/5 or poe.restart_energy_port = 1-3 or equivalent poe.restart_energy_port = 1/1-1/3. | |||||||||||||||||||||
| TconfigTable | 1.3.6.1.4.1.3181.10.6.1.33.4 | NA | |||||||||||||||||||
table · not-accessible · current Power over Ethernet function permits the powering of connected units which do not use their own local power supply. | |||||||||||||||||||||
| RconfigEntry | 1.3.6.1.4.1.3181.10.6.1.33.4.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CconfigPortIndex | 1.3.6.1.4.1.3181.10.6.1.33.4.1.1 | INTEGER (0..24) | NA | ||||||||||||||||||
column · INTEGER (0..24) · not-accessible · current Automatically generated | |||||||||||||||||||||
| CconfigMode | 1.3.6.1.4.1.3181.10.6.1.33.4.1.2 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Used to enable or disable PoE function.
| |||||||||||||||||||||
| CconfigPriorityPort | 1.3.6.1.4.1.3181.10.6.1.33.4.1.3 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Ports without priority may be switched off under a power contention situation.
| |||||||||||||||||||||
| CconfigEnablePoePlus | 1.3.6.1.4.1.3181.10.6.1.33.4.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Allow between 15-30W power consumption.
| |||||||||||||||||||||
| TwatchdogTable | 1.3.6.1.4.1.3181.10.6.1.33.5 | NA | |||||||||||||||||||
| RwatchdogEntry | 1.3.6.1.4.1.3181.10.6.1.33.5.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CwatchdogPortIndex | 1.3.6.1.4.1.3181.10.6.1.33.5.1.1 | INTEGER (0..24) | NA | ||||||||||||||||||
column · INTEGER (0..24) · not-accessible · current Automatically generated | |||||||||||||||||||||
| CwatchdogTestMethod | 1.3.6.1.4.1.3181.10.6.1.33.5.1.2 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Selects the method with which the attached device is probed. Turn unused to ports, which should not affect PoE, to DISABLE.
| |||||||||||||||||||||
| CwatchdogStartDelay | 1.3.6.1.4.1.3181.10.6.1.33.5.1.3 | Unsigned32 | RW | ||||||||||||||||||
column · Unsigned32 · read-write · current Defines the time in seconds after PoE enable to the first check. This is useful when the device has a long boot time and a short check period is used. Effectively this delays the first check. | |||||||||||||||||||||
| CwatchdogCheckInterval | 1.3.6.1.4.1.3181.10.6.1.33.5.1.4 | Unsigned32 | RW | ||||||||||||||||||
column · Unsigned32 · read-write · current Defines the time in seconds between successive checks. If set to 0 only manual checks via the test_now command are executed. | |||||||||||||||||||||
| CwatchdogRecheckInterval | 1.3.6.1.4.1.3181.10.6.1.33.5.1.5 | Unsigned32 | RW | ||||||||||||||||||
column · Unsigned32 · read-write · current Defines the time in seconds between successive checks while an error has occured. This parameter permits a long check interval combined with faster checking while an error is suspected. | |||||||||||||||||||||
| CwatchdogTolerableFailures | 1.3.6.1.4.1.3181.10.6.1.33.5.1.6 | Unsigned32 | RW | ||||||||||||||||||
column · Unsigned32 · read-write · current Defines the number of tolerable successive errors before reboot action is taken by toggling PoE. | |||||||||||||||||||||
| CwatchdogMinimumRmonPackets | 1.3.6.1.4.1.3181.10.6.1.33.5.1.7 | Unsigned32 | RW | ||||||||||||||||||
column · Unsigned32 · read-write · current Defines the number of packets that must be received within check interval. Applies to RMON test method only. | |||||||||||||||||||||
| CwatchdogCheckedAddress | 1.3.6.1.4.1.3181.10.6.1.33.5.1.8 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current Defines the IP v4 or v6 address of the checked device. Also accepts hostname. Applies to PING method only. | |||||||||||||||||||||
| CwatchdogClearStatistics | 1.3.6.1.4.1.3181.10.6.1.33.5.1.9 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current Resets statistics counter for this port to 0. | |||||||||||||||||||||
| SpoeTotalPowerConsumed | 1.3.6.1.4.1.3181.10.6.1.33.100 | Unsigned32 | RO | 4537 | |||||||||||||||||
scalar · Unsigned32 · read-only · current The sum of power currently delivered to all ports. (units: mW) Example values from LibreNMS test devices
| |||||||||||||||||||||
| TstatusTable | 1.3.6.1.4.1.3181.10.6.1.33.101 | NA | |||||||||||||||||||
table · not-accessible · current This table list the current PoE port conditions. | |||||||||||||||||||||
| RstatusEntry | 1.3.6.1.4.1.3181.10.6.1.33.101.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CstatusPortIndex | 1.3.6.1.4.1.3181.10.6.1.33.101.1.1 | INTEGER (0..31) | NA | ||||||||||||||||||
column · INTEGER (0..31) · not-accessible · current Automatically generated | |||||||||||||||||||||
| CstatusCondition | 1.3.6.1.4.1.3181.10.6.1.33.101.1.2 | INTEGER | RO | powerOff(1) | |||||||||||||||||
column · INTEGER · read-only · current PoE status and conditions.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CstatusDeterminedClass | 1.3.6.1.4.1.3181.10.6.1.33.101.1.3 | INTEGER | RO | isUnknown(255) | |||||||||||||||||
column · INTEGER · read-only · current Determined and negotiated PoE class.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CstatusOutputCurrent | 1.3.6.1.4.1.3181.10.6.1.33.101.1.4 | Integer32 (0..65535) | RO | 0 | |||||||||||||||||
column · Integer32 (0..65535) · read-only · current Current delivered to the attached device. (units: mA) Example values from LibreNMS test devices
| |||||||||||||||||||||
| CstatusOutputVoltage | 1.3.6.1.4.1.3181.10.6.1.33.101.1.5 | Integer32 (0..65535) | RO | 0 | |||||||||||||||||
column · Integer32 (0..65535) · read-only · current Voltage delivered to the attached device. (units: mV) Example values from LibreNMS test devices
| |||||||||||||||||||||
| CstatusOutputPower | 1.3.6.1.4.1.3181.10.6.1.33.101.1.6 | Integer32 (0..65535) | RO | 0 | |||||||||||||||||
column · Integer32 (0..65535) · read-only · current Calculated power delivered to the attached device. (units: mW) Example values from LibreNMS test devices
| |||||||||||||||||||||
| CstatusPowerDeniedCounter | 1.3.6.1.4.1.3181.10.6.1.33.101.1.7 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current Incremented whenever a PoE request was denied regardless of reason. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CstatusOverCurrentCounter | 1.3.6.1.4.1.3181.10.6.1.33.101.1.8 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current Incremented whenever an over_current condition was detected. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CstatusShortCircuitCounter | 1.3.6.1.4.1.3181.10.6.1.33.101.1.9 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current Incremented whenever a short circuit was detected. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CstatusNumberOfChecks | 1.3.6.1.4.1.3181.10.6.1.33.101.1.10 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current Counts the number of watchdog checks. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CstatusNumberOfFailures | 1.3.6.1.4.1.3181.10.6.1.33.101.1.11 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current Counts the number of failed wachdog checks. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CstatusPoeRestartCounter | 1.3.6.1.4.1.3181.10.6.1.33.101.1.12 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current Counts the number of times PoE was toggled by watchdog to reboot the attached device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TenergySuppliedTable | 1.3.6.1.4.1.3181.10.6.1.33.102 | NA | |||||||||||||||||||
table · not-accessible · current This table list the power provided via PoE ports. The values are automatically updated in the given interval. | |||||||||||||||||||||
| RenergySuppliedEntry | 1.3.6.1.4.1.3181.10.6.1.33.102.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CenergySuppliedPortIndex | 1.3.6.1.4.1.3181.10.6.1.33.102.1.1 | INTEGER (0..31) | NA | ||||||||||||||||||
column · INTEGER (0..31) · not-accessible · current Automatically generated | |||||||||||||||||||||
| CenergySuppliedTimeOfValueRestart | 1.3.6.1.4.1.3181.10.6.1.33.102.1.2 | Counter32 | RO | ||||||||||||||||||
column · Counter32 · read-only · current Time stamp when the statistics counter had been restarted. | |||||||||||||||||||||
| CenergySuppliedTimeSinceValueRestart | 1.3.6.1.4.1.3181.10.6.1.33.102.1.3 | Counter32 | RO | ||||||||||||||||||
column · Counter32 · read-only · current How long ago have the statistics counter been restarted. | |||||||||||||||||||||
| CenergySuppliedLastSecond | 1.3.6.1.4.1.3181.10.6.1.33.102.1.4 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current Energy supplied in the last second. Value in Joule. | |||||||||||||||||||||
| CenergySuppliedAccumulated | 1.3.6.1.4.1.3181.10.6.1.33.102.1.5 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current Energy supplied since last value reset. Value in Wh. (1Wh = 3600 Joule = 3600Ws). | |||||||||||||||||||||