G6-HARDWARE-MIB
MICROSENS GmbH & Co. KGMicrosens private MIB for Generation 6 Ethernet Switches
snmptranslate -m G6-HARDWARE-MIB -Tpsnmpwalk -v2c -c <community> -m G6-HARDWARE-MIB <host> 1.3.6.1.4.1.3181.10.6.1Imports
| MICROSENS-G6-MIB | g6 |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Counter32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, MacAddress, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Idevice | 1.3.6.1.4.1.3181.10.6.1 | ||||||||||||||||
identity Microsens private MIB for Generation 6 Ethernet Switches | |||||||||||||||||
| Nhardware | 1.3.6.1.4.1.3181.10.6.1.31 | ||||||||||||||||
| ShardwareLedTest | 1.3.6.1.4.1.3181.10.6.1.31.1 | DisplayString | RW | ||||||||||||||
scalar · DisplayString · read-write · current Runs a LED test whereby all LED light up in all possible colors for checking their function. The tests terminates within a few seconds. | |||||||||||||||||
| ShardwareLedMode | 1.3.6.1.4.1.3181.10.6.1.31.2 | INTEGER | RW | ||||||||||||||
scalar · INTEGER · read-write · current The LED display can be configured to be less intrusive.
| |||||||||||||||||
| ShardwarePowerSupply1Monitored | 1.3.6.1.4.1.3181.10.6.1.31.3 | INTEGER | RW | ||||||||||||||
scalar · INTEGER · read-write · current When disabled a missing power supply 1 will not turn the associated led red on failure. Do this when single power supply 2 operation is used or when the device is powered solely by PoE. This feature only applies to industrial switches.
| |||||||||||||||||
| ShardwarePowerSupply2Monitored | 1.3.6.1.4.1.3181.10.6.1.31.4 | INTEGER | RW | ||||||||||||||
scalar · INTEGER · read-write · current When disabled a missing power supply 2 will not turn the associated led red on failure. Do this when single power supply 1 operation is used or when the device is powered solely by PoE. This feature only applies to industrial switches.
| |||||||||||||||||
| ShardwareFactoryResetButton | 1.3.6.1.4.1.3181.10.6.1.31.5 | INTEGER | RW | ||||||||||||||
scalar · INTEGER · read-write · current When disabled the factory button will trigger the factory reset function when pressed for a long time. The IP discover function upon a short button click is not affected.
| |||||||||||||||||
| TcableTestConfigTable | 1.3.6.1.4.1.3181.10.6.1.31.6 | NA | |||||||||||||||
table · not-accessible · current The cable tester allows for detection of copper cable faults and can even detect where the fault is located. By using a OTDR SFP, measurements can also be done on fiber ports | |||||||||||||||||
| RcableTestConfigEntry | 1.3.6.1.4.1.3181.10.6.1.31.6.1 | NA | |||||||||||||||
row · not-accessible · current | |||||||||||||||||
| CcableTestConfigPortIndex | 1.3.6.1.4.1.3181.10.6.1.31.6.1.1 | INTEGER (0..24) | NA | ||||||||||||||
column · INTEGER (0..24) · not-accessible · current Automatically generated | |||||||||||||||||
| CcableTestConfigEnableAutoCableTest | 1.3.6.1.4.1.3181.10.6.1.31.6.1.2 | INTEGER | RW | ||||||||||||||
column · INTEGER · read-write · current When enabled a cable test is performed each time the link goes down. The test is only performed for copper ports, dual media ports in copper mode or when an OTDR SFP is detected.
| |||||||||||||||||
| CcableTestConfigEventGeneration | 1.3.6.1.4.1.3181.10.6.1.31.6.1.3 | INTEGER | RW | ||||||||||||||
column · INTEGER · read-write · current When the cable termination status changes or a change in the fiber is detected an event can be raised.
| |||||||||||||||||
| CcableTestConfigReflectionThreshold | 1.3.6.1.4.1.3181.10.6.1.31.6.1.4 | Integer32 (0..65535) | RW | ||||||||||||||
column · Integer32 (0..65535) · read-write · current Select a value up to 508 which is used to decide between a connected cable and a remotely disconnected cable. With actively terminated data ports, the detection is difficult and precise setup is required. Please refer to cable_test_status.reflection_value for further details. Applies to copper only. | |||||||||||||||||
| CcableTestConfigReflectionHysteresis | 1.3.6.1.4.1.3181.10.6.1.31.6.1.5 | Integer32 (0..65535) | RW | ||||||||||||||
column · Integer32 (0..65535) · read-write · current Choose value to prevent oscillation when reflection value is slightly shifting. For OTDR measurement, the value is interpreted as minimum meters of change in a reflection for it to be considered a different reflection. | |||||||||||||||||
| CcableTestConfigStartTestNow | 1.3.6.1.4.1.3181.10.6.1.31.6.1.6 | DisplayString | RW | ||||||||||||||
column · DisplayString · read-write · current May be used to manually start a cable test. ATTENTION: If the port is in link up status it will be forced to link down first. This will disrupt the current data traffic. Therefore, type start_test_now = CONFIRM. | |||||||||||||||||
| CcableTestConfigCreateReference | 1.3.6.1.4.1.3181.10.6.1.31.6.1.7 | DisplayString | RW | ||||||||||||||
column · DisplayString · read-write · current Is used to start a OTDR reference measurement. Only applies to optical cables with the required SFP installed. Type create_reference = CONFIRM. | |||||||||||||||||
| CcableTestConfigReferenceData | 1.3.6.1.4.1.3181.10.6.1.31.6.1.8 | DisplayString | RW | ||||||||||||||
column · DisplayString · read-write · current The content of this field is created with the create_reference action command and should not be edited manually. | |||||||||||||||||
| TioSignalConfigTable | 1.3.6.1.4.1.3181.10.6.1.31.7 | NA | |||||||||||||||
| RioSignalConfigEntry | 1.3.6.1.4.1.3181.10.6.1.31.7.1 | NA | |||||||||||||||
row · not-accessible · current
| |||||||||||||||||
| CioSignalConfigIndex | 1.3.6.1.4.1.3181.10.6.1.31.7.1.1 | INTEGER (0) | NA | ||||||||||||||
column · INTEGER (0) · not-accessible · current Automatically generated | |||||||||||||||||
| CioSignalConfigSignalMode | 1.3.6.1.4.1.3181.10.6.1.31.7.1.2 | INTEGER | RW | ||||||||||||||
column · INTEGER · read-write · current Permit setting of I/O signal LEDs and relays to static or blink mode for increased visualization.
| |||||||||||||||||
| CioSignalConfigInput1Mode | 1.3.6.1.4.1.3181.10.6.1.31.7.1.3 | INTEGER | RW | ||||||||||||||
column · INTEGER · read-write · current When this function is activated the external alarm input 1 is monitored. Note: alarm inputs are not available in all product versions.
| |||||||||||||||||
| CioSignalConfigInput1Name | 1.3.6.1.4.1.3181.10.6.1.31.7.1.4 | DisplayString | RW | ||||||||||||||
column · DisplayString · read-write · current A customer specific name can be specified for input 1. This name will appear in the associated event messages. The name (up to the first blank) determines the attribute used in SmartOffice context. | |||||||||||||||||
| CioSignalConfigInput2Mode | 1.3.6.1.4.1.3181.10.6.1.31.7.1.5 | INTEGER | RW | ||||||||||||||
column · INTEGER · read-write · current When this function is activated the external alarm input 2 is monitored. Note: alarm inputs are not available in all product versions.
| |||||||||||||||||
| CioSignalConfigInput2Name | 1.3.6.1.4.1.3181.10.6.1.31.7.1.6 | DisplayString | RW | ||||||||||||||
column · DisplayString · read-write · current A customer specific name can be specified for input 2. This name will appear in the associated event messages. The name (up to the first blank) determines the attribute used in SmartOffice context. | |||||||||||||||||
| CioSignalConfigOutput1Trigger | 1.3.6.1.4.1.3181.10.6.1.31.7.1.7 | INTEGER | RW | ||||||||||||||
column · INTEGER · read-write · current Defines on which condition the alarm relay 1 is activated. Note: alarm relays are not available in all product versions.
| |||||||||||||||||
| CioSignalConfigOutput1Name | 1.3.6.1.4.1.3181.10.6.1.31.7.1.8 | DisplayString | RW | ||||||||||||||
column · DisplayString · read-write · current A customer specific name can be specified for alarm output 1. This name will appear in the associated event messages. The name (up to the first blank) determines the attribute used in SmartOffice context. | |||||||||||||||||
| CioSignalConfigOutput2Trigger | 1.3.6.1.4.1.3181.10.6.1.31.7.1.9 | INTEGER | RW | ||||||||||||||
column · INTEGER · read-write · current Defines on which condition the alarm relay 2 is activated. Note: alarm relays are not available in all product versions.
| |||||||||||||||||
| CioSignalConfigOutput2Name | 1.3.6.1.4.1.3181.10.6.1.31.7.1.10 | DisplayString | RW | ||||||||||||||
column · DisplayString · read-write · current A customer specific name can be specified for alarm output 2. This name will appear in the associated event messages. The name (up to the first blank) determines the attribute used in SmartOffice context. | |||||||||||||||||
| ShardwarePowerSupply1Status | 1.3.6.1.4.1.3181.10.6.1.31.100 | INTEGER | RO | ok(0) | |||||||||||||
scalar · INTEGER · read-only · current Displays state of primary supply or only supply for single supply systems.
Example values from LibreNMS test devices
| |||||||||||||||||
| ShardwarePowerSupply2Status | 1.3.6.1.4.1.3181.10.6.1.31.101 | INTEGER | RO | notApplicable(4) | |||||||||||||
scalar · INTEGER · read-only · current Displays state of secondary supply if available.
Example values from LibreNMS test devices
| |||||||||||||||||
| ShardwareRunningOnPoe | 1.3.6.1.4.1.3181.10.6.1.31.102 | INTEGER | RO | ||||||||||||||
scalar · INTEGER · read-only · current When set the unit currently operates on the PD input via PoE.
| |||||||||||||||||
| ShardwareFanStatus | 1.3.6.1.4.1.3181.10.6.1.31.103 | INTEGER | RO | unused(0) | |||||||||||||
scalar · INTEGER · read-only · current Displays state of cooling fan. Indicates UNUSED in fanless devices.
Example values from LibreNMS test devices
| |||||||||||||||||
| ShardwareSdCardStatus | 1.3.6.1.4.1.3181.10.6.1.31.104 | INTEGER | RO | empty(0) | |||||||||||||
scalar · INTEGER · read-only · current Current status of SD-card.
Example values from LibreNMS test devices
| |||||||||||||||||
| ShardwareNumOfPorts | 1.3.6.1.4.1.3181.10.6.1.31.105 | Integer32 (0..255) | RO | ||||||||||||||
scalar · Integer32 (0..255) · read-only · current Total number of Ethernet ports this hardware offers. | |||||||||||||||||
| ShardwareMaskOfExistingPorts | 1.3.6.1.4.1.3181.10.6.1.31.106 | OCTET STRING (SIZE (0..4)) | RO | ||||||||||||||
scalar · OCTET STRING (SIZE (0..4)) · read-only · current Set bit for each port that physically existing and could be in use. | |||||||||||||||||
| ShardwareMaskOfSfpPorts | 1.3.6.1.4.1.3181.10.6.1.31.107 | OCTET STRING (SIZE (0..4)) | RO | ||||||||||||||
scalar · OCTET STRING (SIZE (0..4)) · read-only · current Marks which ports support SFPs. | |||||||||||||||||
| ShardwareMaskOfPoePorts | 1.3.6.1.4.1.3181.10.6.1.31.108 | OCTET STRING (SIZE (0..4)) | RO | ||||||||||||||
scalar · OCTET STRING (SIZE (0..4)) · read-only · current Marks which ports support PoE output. | |||||||||||||||||
| TmoduleInfoTable | 1.3.6.1.4.1.3181.10.6.1.31.109 | NA | |||||||||||||||
table · not-accessible · current This section indicates which modules are inserted in the optional extension slots. | |||||||||||||||||
| RmoduleInfoEntry | 1.3.6.1.4.1.3181.10.6.1.31.109.1 | NA | |||||||||||||||
row · not-accessible · current
| |||||||||||||||||
| CmoduleInfoIndex | 1.3.6.1.4.1.3181.10.6.1.31.109.1.1 | INTEGER (0..3) | NA | ||||||||||||||
column · INTEGER (0..3) · not-accessible · current Automatically generated | |||||||||||||||||
| CmoduleInfoUnitType | 1.3.6.1.4.1.3181.10.6.1.31.109.1.2 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Identifies the general type of module.
| |||||||||||||||||
| CmoduleInfoArticleNumber | 1.3.6.1.4.1.3181.10.6.1.31.109.1.3 | DisplayString | RO | ||||||||||||||
column · DisplayString · read-only · current The article number of the module in this slot. | |||||||||||||||||
| CmoduleInfoSerialNumber | 1.3.6.1.4.1.3181.10.6.1.31.109.1.4 | DisplayString | RO | ||||||||||||||
column · DisplayString · read-only · current The serial number of the module in this slot. | |||||||||||||||||
| CmoduleInfoHardwareVersion | 1.3.6.1.4.1.3181.10.6.1.31.109.1.5 | DisplayString | RO | ||||||||||||||
column · DisplayString · read-only · current This device hardware revision number. | |||||||||||||||||
| CmoduleInfoProjectNumber | 1.3.6.1.4.1.3181.10.6.1.31.109.1.6 | DisplayString | RO | ||||||||||||||
column · DisplayString · read-only · current MICROSENS project number. | |||||||||||||||||
| CmoduleInfoOccupiedSlots | 1.3.6.1.4.1.3181.10.6.1.31.109.1.7 | DisplayString | RO | ||||||||||||||
column · DisplayString · read-only · current Lists all slots contained in this module. | |||||||||||||||||
| CmoduleInfoDescription | 1.3.6.1.4.1.3181.10.6.1.31.109.1.8 | DisplayString | RO | ||||||||||||||
column · DisplayString · read-only · current Feature summary of the module. | |||||||||||||||||
| TslotInfoTable | 1.3.6.1.4.1.3181.10.6.1.31.110 | NA | |||||||||||||||
table · not-accessible · current This section indicates which modules are inserted in the optional extension slots. | |||||||||||||||||
| RslotInfoEntry | 1.3.6.1.4.1.3181.10.6.1.31.110.1 | NA | |||||||||||||||
row · not-accessible · current
| |||||||||||||||||
| CslotInfoIndex | 1.3.6.1.4.1.3181.10.6.1.31.110.1.1 | INTEGER (0..7) | NA | ||||||||||||||
column · INTEGER (0..7) · not-accessible · current Automatically generated | |||||||||||||||||
| CslotInfoBoardType | 1.3.6.1.4.1.3181.10.6.1.31.110.1.2 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current General type of board function
| |||||||||||||||||
| CslotInfoBoardId | 1.3.6.1.4.1.3181.10.6.1.31.110.1.3 | Unsigned32 | RO | ||||||||||||||
column · Unsigned32 · read-only · current This identifies the board type for internal operation. | |||||||||||||||||
| CslotInfoVersionBits | 1.3.6.1.4.1.3181.10.6.1.31.110.1.4 | Integer32 (0..255) | RO | ||||||||||||||
column · Integer32 (0..255) · read-only · current Version bits from hardware or backplane. | |||||||||||||||||
| TportInfoTable | 1.3.6.1.4.1.3181.10.6.1.31.111 | NA | |||||||||||||||
table · not-accessible · current Used to map physical to logical port ids. | |||||||||||||||||
| RportInfoEntry | 1.3.6.1.4.1.3181.10.6.1.31.111.1 | NA | |||||||||||||||
row · not-accessible · current
| |||||||||||||||||
| CportInfoPortIndex | 1.3.6.1.4.1.3181.10.6.1.31.111.1.1 | INTEGER (0..24) | NA | ||||||||||||||
column · INTEGER (0..24) · not-accessible · current Automatically generated | |||||||||||||||||
| CportInfoSystemSlot | 1.3.6.1.4.1.3181.10.6.1.31.111.1.2 | Integer32 (0..255) | RO | ||||||||||||||
column · Integer32 (0..255) · read-only · current Describes on which system slot this port index is located. | |||||||||||||||||
| CportInfoSwitchPort | 1.3.6.1.4.1.3181.10.6.1.31.111.1.3 | Integer32 (0..255) | RO | ||||||||||||||
column · Integer32 (0..255) · read-only · current Describes on which switch port this port index is located. | |||||||||||||||||
| CportInfoUserSlot | 1.3.6.1.4.1.3181.10.6.1.31.111.1.4 | Integer32 (0..255) | RO | ||||||||||||||
column · Integer32 (0..255) · read-only · current Slot number as seen by customer. | |||||||||||||||||
| CportInfoUserPort | 1.3.6.1.4.1.3181.10.6.1.31.111.1.5 | Integer32 (0..255) | RO | ||||||||||||||
column · Integer32 (0..255) · read-only · current Port number as seen by customer. | |||||||||||||||||
| CportInfoSnmpPort | 1.3.6.1.4.1.3181.10.6.1.31.111.1.6 | Integer32 (0..65535) | RO | ||||||||||||||
column · Integer32 (0..65535) · read-only · current Slot and port representation as used in SNMP. Formula is Slot*100 + Port. | |||||||||||||||||
| CportInfoSnmpInstance | 1.3.6.1.4.1.3181.10.6.1.31.111.1.7 | Integer32 (0..255) | RO | ||||||||||||||
column · Integer32 (0..255) · read-only · current Port instance counting from 0 to number of ports | |||||||||||||||||
| CportInfoHardwarePort | 1.3.6.1.4.1.3181.10.6.1.31.111.1.8 | Integer32 (0..255) | RO | ||||||||||||||
column · Integer32 (0..255) · read-only · current Port number as used internally. Ports may not be in sequential order. | |||||||||||||||||
| CportInfoInterfaceType | 1.3.6.1.4.1.3181.10.6.1.31.111.1.9 | INTEGER | RO | copper(0) | |||||||||||||
column · INTEGER · read-only · current Identifies port as copper or optical. Also used for snmp ifType definition
Example values from LibreNMS test devices
| |||||||||||||||||
| CportInfoProperties | 1.3.6.1.4.1.3181.10.6.1.31.111.1.10 | Bits | RO | ||||||||||||||
column · Bits · read-only · current Describes which functions the port can support.
| |||||||||||||||||
| TportNamesTable | 1.3.6.1.4.1.3181.10.6.1.31.112 | NA | |||||||||||||||
table · not-accessible · current This table contains additional port information names suitable for use in snmp. | |||||||||||||||||
| RportNamesEntry | 1.3.6.1.4.1.3181.10.6.1.31.112.1 | NA | |||||||||||||||
row · not-accessible · current
| |||||||||||||||||
| CportNamesPortIndex | 1.3.6.1.4.1.3181.10.6.1.31.112.1.1 | INTEGER (0..24) | NA | ||||||||||||||
column · INTEGER (0..24) · not-accessible · current Automatically generated | |||||||||||||||||
| CportNamesCliName | 1.3.6.1.4.1.3181.10.6.1.31.112.1.2 | DisplayString | RO | ||||||||||||||
column · DisplayString · read-only · current Port name as used in cli and as required for ifName (read only) | |||||||||||||||||
| CportNamesPortDescription | 1.3.6.1.4.1.3181.10.6.1.31.112.1.3 | DisplayString | RO | ||||||||||||||
column · DisplayString · read-only · current Port name as required for ifDescription (read only) | |||||||||||||||||
| TportLedsTable | 1.3.6.1.4.1.3181.10.6.1.31.113 | NA | |||||||||||||||
table · not-accessible · current This section indicates the state of all port related LEDs. | |||||||||||||||||
| RportLedsEntry | 1.3.6.1.4.1.3181.10.6.1.31.113.1 | NA | |||||||||||||||
row · not-accessible · current
| |||||||||||||||||
| CportLedsPortIndex | 1.3.6.1.4.1.3181.10.6.1.31.113.1.1 | INTEGER (0..31) | NA | ||||||||||||||
column · INTEGER (0..31) · not-accessible · current Automatically generated | |||||||||||||||||
| CportLedsEthernetColor | 1.3.6.1.4.1.3181.10.6.1.31.113.1.2 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Ethernet Link LED.
| |||||||||||||||||
| CportLedsEthernetBlinking | 1.3.6.1.4.1.3181.10.6.1.31.113.1.3 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Ethernet Link LED.
| |||||||||||||||||
| CportLedsPoeColor | 1.3.6.1.4.1.3181.10.6.1.31.113.1.4 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Power over Ethernet LED. For optical ports this indicates signal detect status.
| |||||||||||||||||
| CportLedsPoeBlinking | 1.3.6.1.4.1.3181.10.6.1.31.113.1.5 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Power over Ethernet LED. For optical ports this indicates signal detect status.
| |||||||||||||||||
| TdeviceLedsTable | 1.3.6.1.4.1.3181.10.6.1.31.114 | NA | |||||||||||||||
table · not-accessible · current This section indicates the state of all LEDs which are not port related. Please note: Not every unit offers all LEDs. | |||||||||||||||||
| RdeviceLedsEntry | 1.3.6.1.4.1.3181.10.6.1.31.114.1 | NA | |||||||||||||||
row · not-accessible · current
| |||||||||||||||||
| CdeviceLedsIndex | 1.3.6.1.4.1.3181.10.6.1.31.114.1.1 | INTEGER (0) | NA | ||||||||||||||
column · INTEGER (0) · not-accessible · current Automatically generated | |||||||||||||||||
| CdeviceLedsSystem1Color | 1.3.6.1.4.1.3181.10.6.1.31.114.1.2 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current This status corresponds to 'sys' LED on some devices.
| |||||||||||||||||
| CdeviceLedsSystem1Blinking | 1.3.6.1.4.1.3181.10.6.1.31.114.1.3 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current This status corresponds to 'sys' LED on some devices.
| |||||||||||||||||
| CdeviceLedsSystem2Color | 1.3.6.1.4.1.3181.10.6.1.31.114.1.4 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Displays external management activity.
| |||||||||||||||||
| CdeviceLedsSystem2Blinking | 1.3.6.1.4.1.3181.10.6.1.31.114.1.5 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Displays external management activity.
| |||||||||||||||||
| CdeviceLedsPowerOn1Color | 1.3.6.1.4.1.3181.10.6.1.31.114.1.6 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current This status corresponds to 'on' LED on some devices.
| |||||||||||||||||
| CdeviceLedsPowerOn1Blinking | 1.3.6.1.4.1.3181.10.6.1.31.114.1.7 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current This status corresponds to 'on' LED on some devices.
| |||||||||||||||||
| CdeviceLedsPowerOn2Color | 1.3.6.1.4.1.3181.10.6.1.31.114.1.8 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Alternative power input LED.
| |||||||||||||||||
| CdeviceLedsPowerOn2Blinking | 1.3.6.1.4.1.3181.10.6.1.31.114.1.9 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Alternative power input LED.
| |||||||||||||||||
| CdeviceLedsRing1Color | 1.3.6.1.4.1.3181.10.6.1.31.114.1.10 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current This LED is used when ring protection is enabled.
| |||||||||||||||||
| CdeviceLedsRing1Blinking | 1.3.6.1.4.1.3181.10.6.1.31.114.1.11 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current This LED is used when ring protection is enabled.
| |||||||||||||||||
| CdeviceLedsRing2Color | 1.3.6.1.4.1.3181.10.6.1.31.114.1.12 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current This LED is used when ring protection is enabled.
| |||||||||||||||||
| CdeviceLedsRing2Blinking | 1.3.6.1.4.1.3181.10.6.1.31.114.1.13 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current This LED is used when ring protection is enabled.
| |||||||||||||||||
| CdeviceLedsSignalIn1Color | 1.3.6.1.4.1.3181.10.6.1.31.114.1.14 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates status of alarm input 1.
| |||||||||||||||||
| CdeviceLedsSignalIn1Blinking | 1.3.6.1.4.1.3181.10.6.1.31.114.1.15 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates status of alarm input 1.
| |||||||||||||||||
| CdeviceLedsSignalIn2Color | 1.3.6.1.4.1.3181.10.6.1.31.114.1.16 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates status of alarm input 2.
| |||||||||||||||||
| CdeviceLedsSignalIn2Blinking | 1.3.6.1.4.1.3181.10.6.1.31.114.1.17 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates status of alarm input 2.
| |||||||||||||||||
| CdeviceLedsSignalOut1Color | 1.3.6.1.4.1.3181.10.6.1.31.114.1.18 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates status of alarm relay output 1.
| |||||||||||||||||
| CdeviceLedsSignalOut1Blinking | 1.3.6.1.4.1.3181.10.6.1.31.114.1.19 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates status of alarm relay output 1.
| |||||||||||||||||
| CdeviceLedsSignalOut2Color | 1.3.6.1.4.1.3181.10.6.1.31.114.1.20 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates status of alarm relay output 2.
| |||||||||||||||||
| CdeviceLedsSignalOut2Blinking | 1.3.6.1.4.1.3181.10.6.1.31.114.1.21 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates status of alarm relay output 2.
| |||||||||||||||||
| TcableTestStatusTable | 1.3.6.1.4.1.3181.10.6.1.31.115 | NA | |||||||||||||||
table · not-accessible · current This table display the result of the last cable test. Values are only available for copper ports while a link is down and if the cable test function is enabled or for optical ports with an OTDR SFP present | |||||||||||||||||
| RcableTestStatusEntry | 1.3.6.1.4.1.3181.10.6.1.31.115.1 | NA | |||||||||||||||
row · not-accessible · current | |||||||||||||||||
| CcableTestStatusPortIndex | 1.3.6.1.4.1.3181.10.6.1.31.115.1.1 | INTEGER (0..24) | NA | ||||||||||||||
column · INTEGER (0..24) · not-accessible · current Automatically generated | |||||||||||||||||
| CcableTestStatusUpdateTimeStamp | 1.3.6.1.4.1.3181.10.6.1.31.115.1.2 | DisplayString | RO | ||||||||||||||
column · DisplayString · read-only · current Indicates the time when this record was last updated. | |||||||||||||||||
| CcableTestStatusPair0State | 1.3.6.1.4.1.3181.10.6.1.31.115.1.3 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates line termination test results for wire pair 0 (Pins 1/2). Applies to copper only.
| |||||||||||||||||
| CcableTestStatusPair0DistanceToFault | 1.3.6.1.4.1.3181.10.6.1.31.115.1.4 | Integer32 (0..65535) | RO | ||||||||||||||
column · Integer32 (0..65535) · read-only · current Distance to fault on wire pair 0 in centimeters. Indicates 0 when no fault is detected or the function is unused. Applies to copper only. | |||||||||||||||||
| CcableTestStatusPair1State | 1.3.6.1.4.1.3181.10.6.1.31.115.1.5 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates line termination test results for wire pair 1 (Pins 3/6). Applies to copper only.
| |||||||||||||||||
| CcableTestStatusPair1DistanceToFault | 1.3.6.1.4.1.3181.10.6.1.31.115.1.6 | Integer32 (0..65535) | RO | ||||||||||||||
column · Integer32 (0..65535) · read-only · current Distance to fault on wire pair 1 in centimeters. Indicates 0 when no fault is detected or the function is unused. Applies to copper only. | |||||||||||||||||
| CcableTestStatusPair2State | 1.3.6.1.4.1.3181.10.6.1.31.115.1.7 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates line termination test results for wire pair 2 (Pins 4/5). Applies to copper only.
| |||||||||||||||||
| CcableTestStatusPair2DistanceToFault | 1.3.6.1.4.1.3181.10.6.1.31.115.1.8 | Integer32 (0..65535) | RO | ||||||||||||||
column · Integer32 (0..65535) · read-only · current Distance to fault on wire pair 2 in centimeters. Indicates 0 when no fault is detected or the function is unused. Applies to copper only. | |||||||||||||||||
| CcableTestStatusPair3State | 1.3.6.1.4.1.3181.10.6.1.31.115.1.9 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates line termination test results for wire pair 3 (Pins 7/8). Applies to copper only.
| |||||||||||||||||
| CcableTestStatusPair3DistanceToFault | 1.3.6.1.4.1.3181.10.6.1.31.115.1.10 | Integer32 (0..65535) | RO | ||||||||||||||
column · Integer32 (0..65535) · read-only · current Distance to fault on wire pair 3 in centimeters. Indicates 0 when no fault is detected or the function is unused. Applies to copper only. | |||||||||||||||||
| CcableTestStatusReflectionValue | 1.3.6.1.4.1.3181.10.6.1.31.115.1.11 | Integer32 (0..65535) | RO | ||||||||||||||
column · Integer32 (0..65535) · read-only · current A unitless value that indicates a measure of reflection level. For difficult to detect actively terminated devices perform a measurement with remotely plugged-in and then unplugged cable. Note the reflection values an choose a value in the middle as reflection_threshold configuration value. Applies to copper only. | |||||||||||||||||
| CcableTestStatusCableStatus | 1.3.6.1.4.1.3181.10.6.1.31.115.1.12 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates the concluded status summary. Applies to copper only.
| |||||||||||||||||
| CcableTestStatusCurrentOtdrReflections | 1.3.6.1.4.1.3181.10.6.1.31.115.1.13 | DisplayString | RO | ||||||||||||||
column · DisplayString · read-only · current Number and location of currently detected reflections for an active OTDR SFP on this port. | |||||||||||||||||
| TioSignalStatusTable | 1.3.6.1.4.1.3181.10.6.1.31.116 | NA | |||||||||||||||
table · not-accessible · current This section is only used for devices which offer external signal inputs and outputs. | |||||||||||||||||
| RioSignalStatusEntry | 1.3.6.1.4.1.3181.10.6.1.31.116.1 | NA | |||||||||||||||
row · not-accessible · current
| |||||||||||||||||
| CioSignalStatusIndex | 1.3.6.1.4.1.3181.10.6.1.31.116.1.1 | INTEGER (0) | NA | ||||||||||||||
column · INTEGER (0) · not-accessible · current Automatically generated | |||||||||||||||||
| CioSignalStatusInput1AlarmActive | 1.3.6.1.4.1.3181.10.6.1.31.116.1.2 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates true when the input 1 is logically active.
| |||||||||||||||||
| CioSignalStatusInput2AlarmActive | 1.3.6.1.4.1.3181.10.6.1.31.116.1.3 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates true when the input 2 is logically active.
| |||||||||||||||||
| CioSignalStatusOutput1RelayActive | 1.3.6.1.4.1.3181.10.6.1.31.116.1.4 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates true when the output 1 relay is activated.
| |||||||||||||||||
| CioSignalStatusOutput2RelayActive | 1.3.6.1.4.1.3181.10.6.1.31.116.1.5 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Indicates true when the output 2 relay is activated.
| |||||||||||||||||
| TtcamStatusTable | 1.3.6.1.4.1.3181.10.6.1.31.117 | NA | |||||||||||||||
table · not-accessible · current The TCAM is a programmable wire speed packet filter. The filter is controlled by the system automatically. This table indicates which filters have been set. | |||||||||||||||||
| RtcamStatusEntry | 1.3.6.1.4.1.3181.10.6.1.31.117.1 | NA | |||||||||||||||
row · not-accessible · current
| |||||||||||||||||
| CtcamStatusIndex | 1.3.6.1.4.1.3181.10.6.1.31.117.1.1 | INTEGER (0..255) | NA | ||||||||||||||
column · INTEGER (0..255) · not-accessible · current Automatically generated | |||||||||||||||||
| CtcamStatusControlFile | 1.3.6.1.4.1.3181.10.6.1.31.117.1.2 | DisplayString | RO | ||||||||||||||
column · DisplayString · read-only · current Reflects the name of the control file associated with this tam entry. | |||||||||||||||||
| CtcamStatusDescription | 1.3.6.1.4.1.3181.10.6.1.31.117.1.3 | DisplayString | RO | ||||||||||||||
column · DisplayString · read-only · current Descriptive text what explains what this TCAM entry will do. | |||||||||||||||||
| TmemoryUtilizationTable | 1.3.6.1.4.1.3181.10.6.1.31.118 | NA | |||||||||||||||
table · not-accessible · current The table indicates memory usage | |||||||||||||||||
| RmemoryUtilizationEntry | 1.3.6.1.4.1.3181.10.6.1.31.118.1 | NA | |||||||||||||||
row · not-accessible · current | |||||||||||||||||
| CmemoryUtilizationIndex | 1.3.6.1.4.1.3181.10.6.1.31.118.1.1 | INTEGER (0) | NA | ||||||||||||||
column · INTEGER (0) · not-accessible · current Automatically generated | |||||||||||||||||
| CmemoryUtilizationFlashFreeMegabyte | 1.3.6.1.4.1.3181.10.6.1.31.118.1.2 | Unsigned32 | RO | ||||||||||||||
column · Unsigned32 · read-only · current Amount of free flash memory in MB | |||||||||||||||||
| CmemoryUtilizationFlashUsedPercent | 1.3.6.1.4.1.3181.10.6.1.31.118.1.3 | Unsigned32 | RO | ||||||||||||||
column · Unsigned32 · read-only · current Amount of flash memory used up in percent | |||||||||||||||||
| CmemoryUtilizationRamDiskFreeMegabyte | 1.3.6.1.4.1.3181.10.6.1.31.118.1.4 | Unsigned32 | RO | ||||||||||||||
column · Unsigned32 · read-only · current Amount of free ram disk memory in MB | |||||||||||||||||
| CmemoryUtilizationRamDiskUsedPercent | 1.3.6.1.4.1.3181.10.6.1.31.118.1.5 | Unsigned32 | RO | ||||||||||||||
column · Unsigned32 · read-only · current Amount of ram disk memory used up in percent | |||||||||||||||||