LINKSYS-POE-MIB
LinksysAdd a new field in the PoE MIB to indicate Max power allocation allowed
snmptranslate -m LINKSYS-POE-MIB -Tpsnmpwalk -v2c -c <community> -m LINKSYS-POE-MIB <host> 1.3.6.1.4.1.3955.1000.201.108Imports
| LINKSYS-MIB | rnd |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION, TruthValue |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IrlPoe | 1.3.6.1.4.1.3955.1000.201.108 | ||||||||||||||||||||
identity Add a new field in the PoE MIB to indicate Max power allocation allowed | |||||||||||||||||||||
| TrlPethPsePortTable | 1.3.6.1.4.1.3955.1000.201.108.1 | NA | |||||||||||||||||||
table · not-accessible · current The table listing additional information for Power Over Ethernet ports. | |||||||||||||||||||||
| RrlPethPsePortEntry | 1.3.6.1.4.1.3955.1000.201.108.1.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the rlPethPsePortTable. | |||||||||||||||||||||
| CrlPethPsePortGroupIndex | 1.3.6.1.4.1.3955.1000.201.108.1.1.1 | INTEGER (1..2147483647) | NA | ||||||||||||||||||
column · INTEGER (1..2147483647) · not-accessible · current This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethMainPseGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in the rack. | |||||||||||||||||||||
| CrlPethPsePortIndex | 1.3.6.1.4.1.3955.1000.201.108.1.1.2 | INTEGER (1..2147483647) | NA | ||||||||||||||||||
column · INTEGER (1..2147483647) · not-accessible · current This variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE entry is connected. | |||||||||||||||||||||
| CrlPethPsePortOutputVoltage | 1.3.6.1.4.1.3955.1000.201.108.1.1.3 | INTEGER (0..2147483647) | RO | ||||||||||||||||||
column · INTEGER (0..2147483647) · read-only · current This variable indicates on the output voltage level in milli volts from rlPethPsePortIndex. | |||||||||||||||||||||
| CrlPethPsePortOutputCurrent | 1.3.6.1.4.1.3955.1000.201.108.1.1.4 | INTEGER (0..2147483647) | RO | ||||||||||||||||||
column · INTEGER (0..2147483647) · read-only · current This variable indicates on the output current level in milli amper from rlPethPsePortIndex. | |||||||||||||||||||||
| CrlPethPsePortOutputPower | 1.3.6.1.4.1.3955.1000.201.108.1.1.5 | INTEGER (0..2147483647) | RO | 0 | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · current This variable indicates on the output power level in milli watts from rlPethPsePortIndex. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CrlPethPsePortPowerLimit | 1.3.6.1.4.1.3955.1000.201.108.1.1.6 | INTEGER (0..2147483647) | RW | 30000 | |||||||||||||||||
column · INTEGER (0..2147483647) · read-write · current This variable indicates on the user configured power level in milli watts which is available from rlPethPsePortIndex. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CrlPethPsePortStatus | 1.3.6.1.4.1.3955.1000.201.108.1.1.7 | INTEGER (0..2147483647) | RO | ||||||||||||||||||
column · INTEGER (0..2147483647) · read-only · current This variable indicates on the hardware status of rlPethPsePortIndex. | |||||||||||||||||||||
| CrlPethPsePortStatusDescription | 1.3.6.1.4.1.3955.1000.201.108.1.1.8 | DisplayString (SIZE (0..80)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..80)) · read-only · current This variable indicates the description of the hardware status of rlPethPsePortIndex. | |||||||||||||||||||||
| CrlPethPsePortOperPowerLimit | 1.3.6.1.4.1.3955.1000.201.108.1.1.9 | INTEGER (0..2147483647) | RO | ||||||||||||||||||
column · INTEGER (0..2147483647) · read-only · current This variable indicates the maximum power level in milli watts which is available from rlPethPsePortIndex. | |||||||||||||||||||||
| CrlPethPsePortSupportPoePlus | 1.3.6.1.4.1.3955.1000.201.108.1.1.10 | TruthValue | RO | ||||||||||||||||||
column · TruthValue · read-only · current This variable indicates if the port supports poe plus. | |||||||||||||||||||||
| CrlPethPsePortTimeRangeName | 1.3.6.1.4.1.3955.1000.201.108.1.1.11 | DisplayString (SIZE (0..32)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-write · current This variable is used to bind PoE port to time range. | |||||||||||||||||||||
| CrlPethPsePortOperStatus | 1.3.6.1.4.1.3955.1000.201.108.1.1.12 | TruthValue | RO | ||||||||||||||||||
column · TruthValue · read-only · current This Read-Only variable indicates PoE port current status affected by time range active/inactive and admin status. | |||||||||||||||||||||
| CrlPethPsePortMaxPowerAllocAllowed | 1.3.6.1.4.1.3955.1000.201.108.1.1.13 | INTEGER (0..2147483647) | RO | ||||||||||||||||||
column · INTEGER (0..2147483647) · read-only · current This variable indicates the maximum power allocation allowed per port (including wire power loses) in milli-watts which is available from rlPethPsePortIndex. | |||||||||||||||||||||
| CrlPethPsePortSupportPoe | 1.3.6.1.4.1.3955.1000.201.108.1.1.14 | TruthValue | RO | ||||||||||||||||||
column · TruthValue · read-only · current This variable indicates if the port is a poe port | |||||||||||||||||||||
| TrlPethMainPseTable | 1.3.6.1.4.1.3955.1000.201.108.2 | NA | |||||||||||||||||||
table · not-accessible · current The table listing additional read - only information for Power Over Ethernet. | |||||||||||||||||||||
| RrlPethMainPseEntry | 1.3.6.1.4.1.3955.1000.201.108.2.1 | NA | |||||||||||||||||||
| CrlPethMainPseGroupIndex | 1.3.6.1.4.1.3955.1000.201.108.2.1.1 | INTEGER (1..2147483647) | NA | ||||||||||||||||||
column · INTEGER (1..2147483647) · not-accessible · current This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethMainPseGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in the rack. | |||||||||||||||||||||
| CrlPethMainPseSwVersion | 1.3.6.1.4.1.3955.1000.201.108.2.1.2 | DisplayString (SIZE (0..20)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..20)) · read-only · current This variable identifies the MCU SW version. | |||||||||||||||||||||
| CrlPethMainPseHwVersion | 1.3.6.1.4.1.3955.1000.201.108.2.1.3 | DisplayString (SIZE (0..20)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..20)) · read-only · current This variable identifies the MCU HW version. | |||||||||||||||||||||
| CrlPethMainPseHwType | 1.3.6.1.4.1.3955.1000.201.108.2.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This variable identifies the MCU HW type (enhanced, plus, none).
| |||||||||||||||||||||
| CrlPethMainPsePowerGuardBand | 1.3.6.1.4.1.3955.1000.201.108.2.1.5 | INTEGER (0..2147483647) | RO | ||||||||||||||||||
column · INTEGER (0..2147483647) · read-only · current This variable identifies the guard band in [W] for not connecting additional ports. | |||||||||||||||||||||
| TrlPethPowerPseTable | 1.3.6.1.4.1.3955.1000.201.108.3 | NA | |||||||||||||||||||
table · not-accessible · current The table listing additional read-write information for Power Over Ethernet. | |||||||||||||||||||||
| RrlPethPowerPseEntry | 1.3.6.1.4.1.3955.1000.201.108.3.1 | NA | |||||||||||||||||||
| CrlPethPowerPseGroupIndex | 1.3.6.1.4.1.3955.1000.201.108.3.1.1 | INTEGER (1..8) | NA | ||||||||||||||||||
column · INTEGER (1..8) · not-accessible · current This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, PethPowerPseGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in the rack. | |||||||||||||||||||||
| CrlPethPowerPsePower | 1.3.6.1.4.1.3955.1000.201.108.3.1.2 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This variable identifies the maximum power in [W] supplied by PSE.
| |||||||||||||||||||||
| CrlPethPowerPseRpsPower | 1.3.6.1.4.1.3955.1000.201.108.3.1.3 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This variable identifies the maximum power in [W] supplied by PSE + RPS.
| |||||||||||||||||||||
| CrlPethPowerPsePowerManagementMode | 1.3.6.1.4.1.3955.1000.201.108.3.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This variable identifies power management mode.
| |||||||||||||||||||||
| CrlPethPowerPsedisconnectMethod | 1.3.6.1.4.1.3955.1000.201.108.3.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This variable identifies disconnect method.
| |||||||||||||||||||||
| CrlPethPowerPseTemperatureSensor | 1.3.6.1.4.1.3955.1000.201.108.3.1.6 | INTEGER (-200..200) | RO | ||||||||||||||||||
column · INTEGER (-200..200) · read-only · current This variable identifies the pd temperature sensor. | |||||||||||||||||||||
| CrlPethPowerPseInrushTestEnabled | 1.3.6.1.4.1.3955.1000.201.108.3.1.7 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This variable identifies if HW inrush test will be disabled. by default HW inrush test is enabled.
| |||||||||||||||||||||