LENOVO-XCC-MIB
Lenovo Enterprise Business GroupThis MIB is to be used to provide monitoring information support for Lenovo XClarity Controller (XCC)
snmptranslate -m LENOVO-XCC-MIB -Tpsnmpwalk -v2c -c <community> -m LENOVO-XCC-MIB <host> 1.3.6.1.4.1.19046.11.1Imports
| INET-ADDRESS-MIB | InetAddressIPv6 |
|---|---|
| LENOVO-SMI-MIB | lenovoServerMibs |
| RFC1155-SMI | Gauge32 |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IlenovoXCCMIB | 1.3.6.1.4.1.19046.11.1 | ||||||||||||||||||||
identity This MIB is to be used to provide monitoring information support for Lenovo XClarity Controller (XCC) | |||||||||||||||||||||
| Nmonitors | 1.3.6.1.4.1.19046.11.1.1 | ||||||||||||||||||||
| Ntemperature | 1.3.6.1.4.1.19046.11.1.1.1 | ||||||||||||||||||||
| StempNumber | 1.3.6.1.4.1.19046.11.1.1.1.1 | INTEGER | RO | mandatory | 4 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The present number of rows in the temperature table. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TtempTable | 1.3.6.1.4.1.19046.11.1.1.1.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory This table contains temperature measurement information. | |||||||||||||||||||||
| RtempEntry | 1.3.6.1.4.1.19046.11.1.1.1.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each row contains parameters related to a temperature measurement channel.
| |||||||||||||||||||||
| CtempIndex | 1.3.6.1.4.1.19046.11.1.1.1.2.1.1 | INTEGER (1..100) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (1..100) · read-only · mandatory This column is used to identify a particular temperature measurement channel. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtempDescr | 1.3.6.1.4.1.19046.11.1.1.1.2.1.2 | DisplayString (SIZE (0..31)) | RO | mandatory | CPU Temp | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory A description of the temperature measurement channel. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtempReading | 1.3.6.1.4.1.19046.11.1.1.1.2.1.3 | DisplayString (SIZE (0..31)) | RO | mandatory | 19 | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The measured temperature.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtempNominalReading | 1.3.6.1.4.1.19046.11.1.1.1.2.1.4 | DisplayString (SIZE (0..31)) | RO | mandatory | 22 | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The nominal temperature, if available.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtempNonRecovLimitHigh | 1.3.6.1.4.1.19046.11.1.1.1.2.1.5 | DisplayString (SIZE (0..31)) | RO | mandatory | N/A | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The non-recoverable limit for the measured temperature. If the measured value rises above this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtempCritLimitHigh | 1.3.6.1.4.1.19046.11.1.1.1.2.1.6 | DisplayString (SIZE (0..31)) | RO | mandatory | N/A | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The critical limit for the measured temperature. If the measured value rises above this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtempNonCritLimitHigh | 1.3.6.1.4.1.19046.11.1.1.1.2.1.7 | DisplayString (SIZE (0..31)) | RO | mandatory | N/A | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The non-critical limit for the measured temperature. If the measured value rises above this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtempNonRecovLimitLow | 1.3.6.1.4.1.19046.11.1.1.1.2.1.8 | DisplayString (SIZE (0..31)) | RO | mandatory | N/A | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The non-recoverable limit for the measured temperature. If the measured value falls below this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtempCritLimitLow | 1.3.6.1.4.1.19046.11.1.1.1.2.1.9 | DisplayString (SIZE (0..31)) | RO | mandatory | N/A | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The critical limit for the measured temperature. If the measured value falls below this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtempNonCritLimitLow | 1.3.6.1.4.1.19046.11.1.1.1.2.1.10 | DisplayString (SIZE (0..31)) | RO | mandatory | N/A | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The non-critical limit for the measured temperature. If the measured value falls below this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtempHealthStatus | 1.3.6.1.4.1.19046.11.1.1.1.2.1.11 | DisplayString (SIZE (0..31)) | RO | mandatory | Normal | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory A description of the temperature component status. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nvoltage | 1.3.6.1.4.1.19046.11.1.1.2 | ||||||||||||||||||||
| SvoltNumber | 1.3.6.1.4.1.19046.11.1.1.2.1 | INTEGER | RO | mandatory | 4 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The present number of rows in the voltage table. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TvoltTable | 1.3.6.1.4.1.19046.11.1.1.2.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory This table contains voltage measurement information. | |||||||||||||||||||||
| RvoltEntry | 1.3.6.1.4.1.19046.11.1.1.2.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each row contains parameters related to a voltage measurement channel.
| |||||||||||||||||||||
| CvoltIndex | 1.3.6.1.4.1.19046.11.1.1.2.2.1.1 | INTEGER (1..1000) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory This column is used to identify a particular voltage measurement channel. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltDescr | 1.3.6.1.4.1.19046.11.1.1.2.2.1.2 | DisplayString (SIZE (0..31)) | RO | mandatory | CMOS Battery | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory A description of the voltage measurement channel. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltReading | 1.3.6.1.4.1.19046.11.1.1.2.2.1.3 | DisplayString (SIZE (0..31)) | RO | mandatory | 3.1200 | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The measured voltage.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltNominalReading | 1.3.6.1.4.1.19046.11.1.1.2.2.1.4 | DisplayString (SIZE (0..31)) | RO | mandatory | 3.0160 | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The nominal voltage, if available.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltNonRecovLimitHigh | 1.3.6.1.4.1.19046.11.1.1.2.2.1.5 | DisplayString (SIZE (0..31)) | RO | mandatory | N/A | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The high non-recoverable limit for the measured voltage. If the measured value falls above this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltCritLimitHigh | 1.3.6.1.4.1.19046.11.1.1.2.2.1.6 | DisplayString (SIZE (0..31)) | RO | mandatory | N/A | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The high critical limit for the measured voltage. If the measured value rises above this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltNonCritLimitHigh | 1.3.6.1.4.1.19046.11.1.1.2.2.1.7 | DisplayString (SIZE (0..31)) | RO | mandatory | N/A | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The high non-critical limit for the measured voltage. If the measured value rises above this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltNonRecovLimitLow | 1.3.6.1.4.1.19046.11.1.1.2.2.1.8 | DisplayString (SIZE (0..31)) | RO | mandatory | N/A | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The low non-recoverable limit for the measured voltage. If the measured value falls below this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltCritLimitLow | 1.3.6.1.4.1.19046.11.1.1.2.2.1.9 | DisplayString (SIZE (0..31)) | RO | mandatory | 2.2490 | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The low critical limit for the measured voltage. If the measured value falls below this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltNonCritLimitLow | 1.3.6.1.4.1.19046.11.1.1.2.2.1.10 | DisplayString (SIZE (0..31)) | RO | mandatory | 2.3920 | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory The low non-critical limit for the measured voltage. If the measured value falls below this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltHealthStatus | 1.3.6.1.4.1.19046.11.1.1.2.2.1.11 | DisplayString (SIZE (0..31)) | RO | mandatory | Normal | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory A description of the voltage component status. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nfans | 1.3.6.1.4.1.19046.11.1.1.3 | ||||||||||||||||||||
| SfanNumber | 1.3.6.1.4.1.19046.11.1.1.3.1 | INTEGER | RO | mandatory | 4 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The present number of rows in the fan table. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TfanTable | 1.3.6.1.4.1.19046.11.1.1.3.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory This table contains fan information. | |||||||||||||||||||||
| RfanEntry | 1.3.6.1.4.1.19046.11.1.1.3.2.1 | NA | mandatory | ||||||||||||||||||
| CfanIndex | 1.3.6.1.4.1.19046.11.1.1.3.2.1.1 | INTEGER (1..100) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (1..100) · read-only · mandatory This column is used to identify a particular fan. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfanDescr | 1.3.6.1.4.1.19046.11.1.1.3.2.1.2 | DisplayString (SIZE (0..31)) | RO | mandatory | Fan 1 Tach | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory A description of the fan measurement channel. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfanSpeed | 1.3.6.1.4.1.19046.11.1.1.3.2.1.3 | OCTET STRING | RO | mandatory | 23% of maximum | ||||||||||||||||
column · OCTET STRING · read-only · mandatory Fan speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the fan is determined not to be running or the fan speed cannot be determined, the string will indicate 'Offline'. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfanNonRecovLimitHigh | 1.3.6.1.4.1.19046.11.1.1.3.2.1.4 | Gauge32 | RO | mandatory | 0 | ||||||||||||||||
column · Gauge32 · read-only · mandatory The high non-recoverable limit for the measured fan. If the measured value falls above this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfanCritLimitHigh | 1.3.6.1.4.1.19046.11.1.1.3.2.1.5 | Gauge32 | RO | mandatory | 0 | ||||||||||||||||
column · Gauge32 · read-only · mandatory The high critical limit for the measured fan. If the measured value rises above this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfanNonCritLimitHigh | 1.3.6.1.4.1.19046.11.1.1.3.2.1.6 | Gauge32 | RO | mandatory | 0 | ||||||||||||||||
column · Gauge32 · read-only · mandatory The high non-critical limit for the measured fan. If the measured value rises above this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfanNonRecovLimitLow | 1.3.6.1.4.1.19046.11.1.1.3.2.1.7 | Gauge32 | RO | mandatory | 0 | ||||||||||||||||
column · Gauge32 · read-only · mandatory The low non-recoverable limit for the measured fan. If the measured value falls below this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfanCritLimitLow | 1.3.6.1.4.1.19046.11.1.1.3.2.1.8 | Gauge32 | RO | mandatory | 1552 | ||||||||||||||||
column · Gauge32 · read-only · mandatory The low critical limit for the measured fan. If the measured value falls below this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfanNonCritLimitLow | 1.3.6.1.4.1.19046.11.1.1.3.2.1.9 | Gauge32 | RO | mandatory | 0 | ||||||||||||||||
column · Gauge32 · read-only · mandatory The low non-critical limit for the measured fan. If the measured value falls below this limit a trap is sent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfanHealthStatus | 1.3.6.1.4.1.19046.11.1.1.3.2.1.10 | DisplayString (SIZE (0..31)) | RO | mandatory | Normal | ||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory A description of the fan component status. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NsystemHealth | 1.3.6.1.4.1.19046.11.1.1.4 | ||||||||||||||||||||
| SsystemHealthStat | 1.3.6.1.4.1.19046.11.1.1.4.1 | INTEGER | RO | mandatory | normal(255) | ||||||||||||||||
scalar · INTEGER · read-only · mandatory Indicates status of system health for the
system in which the XCC resides.
Value of 'nonRecoverable' indicates a severe error has occurred
and the system may not be functioning. A value of
'critical' indicates that a error has occurred but
the system is currently functioning properly. A value of
'nonCritical' indicates that a condition has occurred
that may change the state of the system in the future but currently
the system is working properly. A value of
'normal' indicates that the system is operating normally.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| TsystemHealthSummaryTable | 1.3.6.1.4.1.19046.11.1.1.4.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of System Health summary. Contains more detailed information about the reasons for the overall system health status. | |||||||||||||||||||||
| RsystemHealthSummaryEntry | 1.3.6.1.4.1.19046.11.1.1.4.2.1 | NA | mandatory | ||||||||||||||||||
| CsystemHealthSummaryIndex | 1.3.6.1.4.1.19046.11.1.1.4.2.1.1 | INTEGER (1..1000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory System health summary index. | |||||||||||||||||||||
| CsystemHealthSummarySeverity | 1.3.6.1.4.1.19046.11.1.1.4.2.1.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory System health summary severity. | |||||||||||||||||||||
| CsystemHealthSummaryDescription | 1.3.6.1.4.1.19046.11.1.1.4.2.1.3 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory System health summary description. | |||||||||||||||||||||
| NvpdInformation | 1.3.6.1.4.1.19046.11.1.1.5 | ||||||||||||||||||||
| TxccVpdTable | 1.3.6.1.4.1.19046.11.1.1.5.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of XCC VPD. | |||||||||||||||||||||
| RxccVpdEntry | 1.3.6.1.4.1.19046.11.1.1.5.1.1 | NA | mandatory | ||||||||||||||||||
| CxccVpdIndex | 1.3.6.1.4.1.19046.11.1.1.5.1.1.1 | INTEGER (1..1000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory XCC VPD index. | |||||||||||||||||||||
| CxccVpdType | 1.3.6.1.4.1.19046.11.1.1.5.1.1.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory XCC VPD Type. Indicates either Bios or Diag or spFimware VPD | |||||||||||||||||||||
| CxccVpdVersionString | 1.3.6.1.4.1.19046.11.1.1.5.1.1.3 | OCTET STRING | RO | mandatory | ESX334M 5.50 | ||||||||||||||||
column · OCTET STRING · read-only · mandatory XCC VPD Version Number of the software(Bios/Diag/spFirmware). For XCC the string contains both the Build ID and the Version Number, for example, like '1AOO3A v1.0.1'. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CxccVpdReleaseDate | 1.3.6.1.4.1.19046.11.1.1.5.1.1.4 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory XCC VPD Release Date of when the software(Bios/Diag/spFirmware) was released. | |||||||||||||||||||||
| NmachineVpd | 1.3.6.1.4.1.19046.11.1.1.5.2 | ||||||||||||||||||||
| NmachineLevelVpd | 1.3.6.1.4.1.19046.11.1.1.5.2.1 | ||||||||||||||||||||
| SmachineLevelVpdMachineType | 1.3.6.1.4.1.19046.11.1.1.5.2.1.1 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory Machine type VPD information. | |||||||||||||||||||||
| SmachineLevelVpdMachineModel | 1.3.6.1.4.1.19046.11.1.1.5.2.1.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory Machine model VPD information. | |||||||||||||||||||||
| SmachineLevelSerialNumber | 1.3.6.1.4.1.19046.11.1.1.5.2.1.3 | OCTET STRING | RO | mandatory | J701NYHG | ||||||||||||||||
scalar · OCTET STRING · read-only · mandatory Machine serial number VPD information. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmachineLevelUUID | 1.3.6.1.4.1.19046.11.1.1.5.2.1.4 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory Machine UUID(Universal Unique ID information). | |||||||||||||||||||||
| SmachineLevelProductName | 1.3.6.1.4.1.19046.11.1.1.5.2.1.5 | OCTET STRING | RO | mandatory | ThinkSystem SR630 V3 | ||||||||||||||||
scalar · OCTET STRING · read-only · mandatory Machine Product Name (e.g. System x3650 M2). Example values from LibreNMS test devices
| |||||||||||||||||||||
| TsystemComponentLevelVpdTable | 1.3.6.1.4.1.19046.11.1.1.5.17 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of the system component hardware VPD information. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| RsystemComponentLevelVpdEntry | 1.3.6.1.4.1.19046.11.1.1.5.17.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory System component hardware VPD entry. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcomponentLevelVpdIndex | 1.3.6.1.4.1.19046.11.1.1.5.17.1.1 | INTEGER (1..1000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory System component level VPD index. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcomponentLevelVpdFruNumber | 1.3.6.1.4.1.19046.11.1.1.5.17.1.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory System component level VPD FRU number. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcomponentLevelVpdFruName | 1.3.6.1.4.1.19046.11.1.1.5.17.1.3 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory System component level VPD FRU name. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcomponentLevelVpdSerialNumber | 1.3.6.1.4.1.19046.11.1.1.5.17.1.4 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory System component level VPD serial number. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcomponentLevelVpdManufacturingId | 1.3.6.1.4.1.19046.11.1.1.5.17.1.5 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory System component level VPD manufacturing ID. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| TsystemComponentLevelVpdTrackingTable | 1.3.6.1.4.1.19046.11.1.1.5.18 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of system component hardware VPD tracking activity log. The activity log types depend on ipmifru information in the server but exclude DIMM infromation. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| RsystemComponentLevelVpdTrackingEntry | 1.3.6.1.4.1.19046.11.1.1.5.18.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory System component hardware VPD tracking activity log entry. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcomponentLevelVpdTrackingIndex | 1.3.6.1.4.1.19046.11.1.1.5.18.1.1 | INTEGER (1..1000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory System component level VPD tracking activity log index. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcomponentLevelVpdTrackingFruNumber | 1.3.6.1.4.1.19046.11.1.1.5.18.1.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory System component level VPD tracking activity log FRU number. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcomponentLevelVpdTrackingFruName | 1.3.6.1.4.1.19046.11.1.1.5.18.1.3 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory System component level VPD tracking activity log FRU name. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcomponentLevelVpdTrackingSerialNumber | 1.3.6.1.4.1.19046.11.1.1.5.18.1.4 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory System component level VPD tracking activity log serial number. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcomponentLevelVpdTrackingManufacturingId | 1.3.6.1.4.1.19046.11.1.1.5.18.1.5 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory System component level VPD tracking activity log manufacturing ID. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcomponentLevelVpdTrackingAction | 1.3.6.1.4.1.19046.11.1.1.5.18.1.6 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory System component level VPD tracking activity log action(added/removed). View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcomponentLevelVpdTrackingTimestamp | 1.3.6.1.4.1.19046.11.1.1.5.18.1.7 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory System component level VPD tracking activity log timestanp. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| ThostMACAddressTable | 1.3.6.1.4.1.19046.11.1.1.5.19 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of MAC addresses of the host NICs. For consistent results, view as a table and not as individual entries. | |||||||||||||||||||||
| RhostMACAddressEntry | 1.3.6.1.4.1.19046.11.1.1.5.19.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Host MAC address entry. For consistent results, view as a table and not as individual entries.
| |||||||||||||||||||||
| ChostMACAddressIndex | 1.3.6.1.4.1.19046.11.1.1.5.19.1.1 | INTEGER (1..1000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory Host MAC address index. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| ChostMACAddressDescription | 1.3.6.1.4.1.19046.11.1.1.5.19.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Description of the MAC Address entry. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| ChostMACAddress | 1.3.6.1.4.1.19046.11.1.1.5.19.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Host MAC address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| TsystemCPUVpdTable | 1.3.6.1.4.1.19046.11.1.1.5.20 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of the system CPU VPD information. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| RsystemCPUVpdEntry | 1.3.6.1.4.1.19046.11.1.1.5.20.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory System CPU VPD entry. View as a table and not as individual entries for consistent results.
| |||||||||||||||||||||
| CcpuVpdIndex | 1.3.6.1.4.1.19046.11.1.1.5.20.1.1 | INTEGER (1..1000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory System CPU level VPD index. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcpuVpdDescription | 1.3.6.1.4.1.19046.11.1.1.5.20.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System CPU Description. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcpuVpdSpeed | 1.3.6.1.4.1.19046.11.1.1.5.20.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System cpu speed in MHz. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcpuVpdIdentifier | 1.3.6.1.4.1.19046.11.1.1.5.20.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System CPU Identifier. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcpuVpdType | 1.3.6.1.4.1.19046.11.1.1.5.20.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System cpu Type. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcpuVpdFamily | 1.3.6.1.4.1.19046.11.1.1.5.20.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System cpu Family. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcpuVpdCores | 1.3.6.1.4.1.19046.11.1.1.5.20.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System cpu number of cores. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcpuVpdThreads | 1.3.6.1.4.1.19046.11.1.1.5.20.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System cpu number of threads. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcpuVpdVoltage | 1.3.6.1.4.1.19046.11.1.1.5.20.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System cpu voltage in millivolts (1125 = 1.125 volts). View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcpuVpdDataWidth | 1.3.6.1.4.1.19046.11.1.1.5.20.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System cpu data width in bits. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcpuVpdHealthStatus | 1.3.6.1.4.1.19046.11.1.1.5.20.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System cpu health status. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CcpuVpdCpuModel | 1.3.6.1.4.1.19046.11.1.1.5.20.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System cpu model. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| TsystemMemoryVpdTable | 1.3.6.1.4.1.19046.11.1.1.5.21 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of the system Memory VPD information. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| RsystemMemoryVpdEntry | 1.3.6.1.4.1.19046.11.1.1.5.21.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory System Memory VPD entry. View as a table and not as individual entries for consistent results.
| |||||||||||||||||||||
| CmemoryVpdIndex | 1.3.6.1.4.1.19046.11.1.1.5.21.1.1 | INTEGER (1..1000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory System Memory level VPD index. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CmemoryVpdDescription | 1.3.6.1.4.1.19046.11.1.1.5.21.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System memory Description (e.g. DIMM 1). View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CmemoryVpdPartNumber | 1.3.6.1.4.1.19046.11.1.1.5.21.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System Memory Part Number. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CmemoryVpdFRUSerialNumber | 1.3.6.1.4.1.19046.11.1.1.5.21.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System memory Serial Number. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CmemoryVpdManufactureDate | 1.3.6.1.4.1.19046.11.1.1.5.21.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System memory Manufacture Date in week/year format (e.g. 3609). View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CmemoryVpdType | 1.3.6.1.4.1.19046.11.1.1.5.21.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System memory Type (e.g. DDR III SDRAM). View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CmemoryVpdSize | 1.3.6.1.4.1.19046.11.1.1.5.21.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System memory size in GigaBytes. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CmemoryHealthStatus | 1.3.6.1.4.1.19046.11.1.1.5.21.1.8 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory A description of the memory component status. | |||||||||||||||||||||
| CmemoryConfigSpeed | 1.3.6.1.4.1.19046.11.1.1.5.21.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System configured memory clock speed in MHz. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CmemoryRatedSpeed | 1.3.6.1.4.1.19046.11.1.1.5.21.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System rated memory clock speed in MB/s. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CmemoryLenovoPartNumber | 1.3.6.1.4.1.19046.11.1.1.5.21.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System Memory Lenovo related Part Number. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CmemoryVpdAEPFlag | 1.3.6.1.4.1.19046.11.1.1.5.21.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Judge System DIMM belong to AEP DIMM. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| TsystemAepDIMMVpdTable | 1.3.6.1.4.1.19046.11.1.1.5.22 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of the system AEP DIMM VPD information. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| RsystemAepDIMMVpdEntry | 1.3.6.1.4.1.19046.11.1.1.5.22.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory System AEP DIMM VPD entry. View as a table and not as individual entries for consistent results.
| |||||||||||||||||||||
| CaepDIMMVpdIndex | 1.3.6.1.4.1.19046.11.1.1.5.22.1.1 | INTEGER (1..1000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory System AEP DIMM VPD index. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdMemory | 1.3.6.1.4.1.19046.11.1.1.5.22.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM Description (e.g. DIMM 1). View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdBankLocator | 1.3.6.1.4.1.19046.11.1.1.5.22.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Locator which manage AEP DIMM (e.g CPU 1) . View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdMaxSpeed | 1.3.6.1.4.1.19046.11.1.1.5.22.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM MAX Speed. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdClockSpeed | 1.3.6.1.4.1.19046.11.1.1.5.22.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM Clock Speed. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdManufacturer | 1.3.6.1.4.1.19046.11.1.1.5.22.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM Manufacturer. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdSerialNumber | 1.3.6.1.4.1.19046.11.1.1.5.22.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM Serial Number. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdPartNumber | 1.3.6.1.4.1.19046.11.1.1.5.22.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM Part Number. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdRawCapacity | 1.3.6.1.4.1.19046.11.1.1.5.22.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM Raw Capacity. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdMemoryCapacity | 1.3.6.1.4.1.19046.11.1.1.5.22.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM Memory Capacity. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdAppDirectCapacity | 1.3.6.1.4.1.19046.11.1.1.5.22.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM APP Direct Capacity. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdUnconfiguredCapacity | 1.3.6.1.4.1.19046.11.1.1.5.22.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM Unconfigureed Capacity. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdInaccessibleCapacity | 1.3.6.1.4.1.19046.11.1.1.5.22.1.13 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM Inaccessible Capacity. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdReservedCapacity | 1.3.6.1.4.1.19046.11.1.1.5.22.1.14 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM Reserved Capacity. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdClassification | 1.3.6.1.4.1.19046.11.1.1.5.22.1.15 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM Classification. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdFirmwareVersion | 1.3.6.1.4.1.19046.11.1.1.5.22.1.16 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM Firmware Version. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CaepDIMMVpdSoftwareID | 1.3.6.1.4.1.19046.11.1.1.5.22.1.17 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory System AEP DIMM Software ID. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| Nusers | 1.3.6.1.4.1.19046.11.1.1.6 | ||||||||||||||||||||
| NxccUsers | 1.3.6.1.4.1.19046.11.1.1.6.1 | ||||||||||||||||||||
| TcurrentlyLoggedInTable | 1.3.6.1.4.1.19046.11.1.1.6.1.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of XCC users currently logged in. | |||||||||||||||||||||
| RcurrentlyLoggedInEntry | 1.3.6.1.4.1.19046.11.1.1.6.1.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory XCC users currently logged in entries. | |||||||||||||||||||||
| CcurrentlyLoggedInEntryIndex | 1.3.6.1.4.1.19046.11.1.1.6.1.1.1.1 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Index for XCC users currently logged in. | |||||||||||||||||||||
| CcurrentlyLoggedInEntryUserId | 1.3.6.1.4.1.19046.11.1.1.6.1.1.1.2 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
column · OCTET STRING (SIZE (0..64)) · read-only · mandatory Name for XCC users currently logged in. | |||||||||||||||||||||
| CcurrentlyLoggedInEntryAccMethod | 1.3.6.1.4.1.19046.11.1.1.6.1.1.1.3 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
column · OCTET STRING (SIZE (0..64)) · read-only · mandatory Access method for XCC users currently logged in. | |||||||||||||||||||||
| Nleds | 1.3.6.1.4.1.19046.11.1.1.8 | ||||||||||||||||||||
| SidentityLED | 1.3.6.1.4.1.19046.11.1.1.8.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Indicates whether the front panel identity LED is on,off, or blinking and allows user to change it.
| |||||||||||||||||||||
| TallLEDsTable | 1.3.6.1.4.1.19046.11.1.1.8.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of LEDs detailed information. | |||||||||||||||||||||
| RallLEDsEntry | 1.3.6.1.4.1.19046.11.1.1.8.2.1 | NA | mandatory | ||||||||||||||||||
| CledIndex | 1.3.6.1.4.1.19046.11.1.1.8.2.1.1 | INTEGER (1..1000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory The LED index number. For consistent results, view as a table and not as individual entries. | |||||||||||||||||||||
| CledIdentifier | 1.3.6.1.4.1.19046.11.1.1.8.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The unique identifier for this LED For consistent results, view as a table and not as individual entries. | |||||||||||||||||||||
| CledLabel | 1.3.6.1.4.1.19046.11.1.1.8.2.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Text label for a LED. For consistent results, view as a table and not as individual entries. | |||||||||||||||||||||
| CledState | 1.3.6.1.4.1.19046.11.1.1.8.2.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Text description which denotes color or on/off/blink state for a LED. For consistent results, view as a table and not as individual entries.
| |||||||||||||||||||||
| CledColor | 1.3.6.1.4.1.19046.11.1.1.8.2.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Color of this LED. For consistent results, view as a table and not as individual entries. | |||||||||||||||||||||
| SinformationLED | 1.3.6.1.4.1.19046.11.1.1.8.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Indicates whether the front panel Information LED is on,off, or blinking and allows user to change it. The only value the user is allowed to enter is 0 for off. User may not turn this LED on or cause it to blink.
| |||||||||||||||||||||
| NfuelGauge | 1.3.6.1.4.1.19046.11.1.1.10 | ||||||||||||||||||||
| NfuelGaugeInformation | 1.3.6.1.4.1.19046.11.1.1.10.1 | ||||||||||||||||||||
| SfuelGaugePowerCappingPolicySetting | 1.3.6.1.4.1.19046.11.1.1.10.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Power Capping Policy. Rack system only. No Power Limit - The maximum power limit will be determined by the active Power Redundancy policy. Static Power Limit - Sets the overall system power limit. In a situation where powering on a component would cause the limit to be exceeded, the component would not be permitted to power on.
| |||||||||||||||||||||
| SfuelGaugeStaticPowerPcapSoftMin | 1.3.6.1.4.1.19046.11.1.1.10.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This field displays power capping soft minimum value. Rack system only. | |||||||||||||||||||||
| SfuelGaugeStaticPowerPcapMin | 1.3.6.1.4.1.19046.11.1.1.10.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This field displays power capping minimum value. Rack system only. | |||||||||||||||||||||
| SfuelGaugeStaticPowerPcapCurrentSetting | 1.3.6.1.4.1.19046.11.1.1.10.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This field is used to display or set the current power capping value. Rack system only. | |||||||||||||||||||||
| SfuelGaugeStaticPowerPcapMax | 1.3.6.1.4.1.19046.11.1.1.10.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This field displays power capping maximum value. Rack system only. | |||||||||||||||||||||
| SfuelGaugeStaticPowerPcapMode | 1.3.6.1.4.1.19046.11.1.1.10.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This field is used to display or set the all Power Cap settings to output or input. Rack system only.
| |||||||||||||||||||||
| SfuelGaugeSystemMaxPower | 1.3.6.1.4.1.19046.11.1.1.10.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This field displays the system maximum power available value. Rack system only. | |||||||||||||||||||||
| SfuelGaugePowerRemaining | 1.3.6.1.4.1.19046.11.1.1.10.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This field displays power remaining value. Rack system only. | |||||||||||||||||||||
| SfuelGaugeTotalPowerAvailable | 1.3.6.1.4.1.19046.11.1.1.10.1.9 | INTEGER | RO | mandatory | 1800 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory This field displays the calculated total remaining power available value. Rack system only. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SfuelGaugeTotalPowerInUse | 1.3.6.1.4.1.19046.11.1.1.10.1.10 | INTEGER | RO | mandatory | 99 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory This field displays total power in use value. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SfuelGaugePowerConsumptionCpu | 1.3.6.1.4.1.19046.11.1.1.10.1.11 | INTEGER | RO | mandatory | 53 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory This field displays the power consumption of the processors. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SfuelGaugePowerConsumptionMemory | 1.3.6.1.4.1.19046.11.1.1.10.1.12 | INTEGER | RO | mandatory | 6 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory This field displays the power consumption of the memory. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SfuelGaugePowerConsumptionOther | 1.3.6.1.4.1.19046.11.1.1.10.1.13 | INTEGER | RO | mandatory | 54 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory This field displays the power consumption of other entities than processors and memory. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NpowerPolicyInformation | 1.3.6.1.4.1.19046.11.1.1.10.2 | ||||||||||||||||||||
| TpowerPolicyTable | 1.3.6.1.4.1.19046.11.1.1.10.2.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Power Policy information for all power domains. Reading this table information about the available power policies that can be configured and which is currently selected. Rack system only | |||||||||||||||||||||
| RpowerPolicyEntry | 1.3.6.1.4.1.19046.11.1.1.10.2.1.1 | NA | mandatory | ||||||||||||||||||
| CpowerPolicyIndex | 1.3.6.1.4.1.19046.11.1.1.10.2.1.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The unique idenitifier of a row in the powerPolicyTable. | |||||||||||||||||||||
| CpowerPolicyName | 1.3.6.1.4.1.19046.11.1.1.10.2.1.1.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory The short name of the power policy. The following are the possible names and their detailed description:
Power Module Redundant
In redundant mode, the server is guaranteed to continue to remain operational with the loss of one power supply
Power Module Non-Redundant
In non-redundant mode, the server is not guaranteed to remain operational with the loss of a power supply. The system will throttle if a power supply fails in an attempt to stay up and running. | |||||||||||||||||||||
| CpowerPolicyPwrSupplyFailureLimit | 1.3.6.1.4.1.19046.11.1.1.10.2.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The maximum number of power supplies that can fail in a chassis while still providing redundancy. | |||||||||||||||||||||
| CpowerPolicyMaxPowerLimit | 1.3.6.1.4.1.19046.11.1.1.10.2.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The maximum power available (in watts), based on the number of power modules and the Power Management Policy setting. | |||||||||||||||||||||
| CpowerPolicyEstimatedUtilization | 1.3.6.1.4.1.19046.11.1.1.10.2.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The estimated utilization (as a percentage) based on current power usage. | |||||||||||||||||||||
| CpowerPolicyActivate | 1.3.6.1.4.1.19046.11.1.1.10.2.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This object provides the status of this power policy. If the value is enabled(1), it means this is the active power policy for the associated domain. When set to a value of enabled(1), the power policy will be made the active one for the associated domain. A set of disabled(0) is not allowed.
| |||||||||||||||||||||
| NpowerRestorePolicyControl | 1.3.6.1.4.1.19046.11.1.1.10.2.2 | ||||||||||||||||||||
| SpowerRestorePolicy | 1.3.6.1.4.1.19046.11.1.1.10.2.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Power Restore Policy determines the mode of operation if a power loss occurs. This setting can also be configured via BIOS F1 setup. Rack system only. alwaysoff: System will remain off once power is restored. restore: Restores system to the same state it was before power failed. alwayson: System will automatically power on once power is restored.
| |||||||||||||||||||||
| SpowerRestoreDelay | 1.3.6.1.4.1.19046.11.1.1.10.2.2.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Power Restore Delay is executed when power restore policy is set to alwayson or restore(if the previous state was power-on). Rack system only. disabled: Power on the server without after AC is restored. random: Provide a random delay between 1 and 15 seconds from the time when AC is restored to the time when the server is automatically powered on.
| |||||||||||||||||||||
| NpowerPowerTrending | 1.3.6.1.4.1.19046.11.1.1.10.3 | ||||||||||||||||||||
| TpowerTrendingSampleTable | 1.3.6.1.4.1.19046.11.1.1.10.3.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Power Domain 1 Power Trending Information. | |||||||||||||||||||||
| RpowerTrendingSampleEntry | 1.3.6.1.4.1.19046.11.1.1.10.3.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Power Domain 1 Power Trending Sample entry. | |||||||||||||||||||||
| CpowerTrendingSampleIndex | 1.3.6.1.4.1.19046.11.1.1.10.3.1.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Power Trending Sample Table Index. | |||||||||||||||||||||
| CpowerTrendingSampleTimeStamp | 1.3.6.1.4.1.19046.11.1.1.10.3.1.1.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory Power Trending Sample Table Timestamp. | |||||||||||||||||||||
| CpowerTrendingSampleInputAve | 1.3.6.1.4.1.19046.11.1.1.10.3.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Power Trending Table Input Average Power in the last 24 hours. | |||||||||||||||||||||
| CpowerTrendingSampleInputMin | 1.3.6.1.4.1.19046.11.1.1.10.3.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Power Trending Table Input Minimum Power in the last 24 hours. | |||||||||||||||||||||
| CpowerTrendingSampleInputMax | 1.3.6.1.4.1.19046.11.1.1.10.3.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Power Trending Table Input Maximum Power in the last 24 hours. | |||||||||||||||||||||
| CpowerTrendingSampleOutputAve | 1.3.6.1.4.1.19046.11.1.1.10.3.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Power Trending Table Output Average Power in the last 24 hours. | |||||||||||||||||||||
| CpowerTrendingSampleOutputMin | 1.3.6.1.4.1.19046.11.1.1.10.3.1.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Power Trending Table Output Minimum Power in the last 24 hours. | |||||||||||||||||||||
| CpowerTrendingSampleOutputMax | 1.3.6.1.4.1.19046.11.1.1.10.3.1.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Power Trending Table Output Maximum Power in the last 24 hours. | |||||||||||||||||||||
| NpowerModule | 1.3.6.1.4.1.19046.11.1.1.11 | ||||||||||||||||||||
| SpowerNumber | 1.3.6.1.4.1.19046.11.1.1.11.1 | Gauge32 | RO | mandatory | |||||||||||||||||
scalar · Gauge32 · read-only · mandatory The present number of rows in the power module table. Rack system only. | |||||||||||||||||||||
| TpowerTable | 1.3.6.1.4.1.19046.11.1.1.11.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory This table contains power inventory information. Rack system only. | |||||||||||||||||||||
| RpowerEntry | 1.3.6.1.4.1.19046.11.1.1.11.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each row contains parameters related to a power module inventory channel.
| |||||||||||||||||||||
| CpowerIndex | 1.3.6.1.4.1.19046.11.1.1.11.2.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory This column is used to identify a particular power module inventory channel. | |||||||||||||||||||||
| CpowerFruName | 1.3.6.1.4.1.19046.11.1.1.11.2.1.2 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory power module FRU name. | |||||||||||||||||||||
| CpowerPartNumber | 1.3.6.1.4.1.19046.11.1.1.11.2.1.3 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory power module Part Number. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CpowerFRUNumber | 1.3.6.1.4.1.19046.11.1.1.11.2.1.4 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory power module FRU Number. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CpowerFRUSerialNumber | 1.3.6.1.4.1.19046.11.1.1.11.2.1.5 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory power module Serial Number. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CpowerHealthStatus | 1.3.6.1.4.1.19046.11.1.1.11.2.1.6 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory A description of the power module status. | |||||||||||||||||||||
| Ndisks | 1.3.6.1.4.1.19046.11.1.1.12 | ||||||||||||||||||||
| SdiskNumber | 1.3.6.1.4.1.19046.11.1.1.12.1 | Gauge32 | RO | mandatory | |||||||||||||||||
scalar · Gauge32 · read-only · mandatory The present number of rows in the disk module table. | |||||||||||||||||||||
| TdiskTable | 1.3.6.1.4.1.19046.11.1.1.12.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory This table contains disk inventory information. | |||||||||||||||||||||
| RdiskEntry | 1.3.6.1.4.1.19046.11.1.1.12.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each row contains parameters related to a disk module inventory channel.
| |||||||||||||||||||||
| CdiskIndex | 1.3.6.1.4.1.19046.11.1.1.12.2.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory This column is used to identify a particular disk module inventory channel. | |||||||||||||||||||||
| CdiskFruName | 1.3.6.1.4.1.19046.11.1.1.12.2.1.2 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory disk module FRU name. | |||||||||||||||||||||
| CdiskHealthStatus | 1.3.6.1.4.1.19046.11.1.1.12.2.1.3 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..31)) · read-only · mandatory A description of the disk module status. | |||||||||||||||||||||
| NlocalStorage | 1.3.6.1.4.1.19046.11.1.1.13 | ||||||||||||||||||||
| Nraid | 1.3.6.1.4.1.19046.11.1.1.13.1 | ||||||||||||||||||||
| SraidOOBCapable | 1.3.6.1.4.1.19046.11.1.1.13.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory If raidOOBCapable is disabled, all the RAID information is not available.
| |||||||||||||||||||||
| TraidControllerTable | 1.3.6.1.4.1.19046.11.1.1.13.1.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Local Storage RAID Controller information. | |||||||||||||||||||||
| RraidControllerEntry | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1 | NA | mandatory | ||||||||||||||||||
| CraidCtrlIndex | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This column is used to identify a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlName | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory This column is used to offer a name of one RAID controller. | |||||||||||||||||||||
| CraidCtrlVPDProdName | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Product Name of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlFWPkgVersion | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Firmware Package Version of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatBCK | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Whether Battery Backup of a particular RAID controller is installed.
| |||||||||||||||||||||
| CraidCtrlVPDManufacture | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Manufacture of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlVPDUUID | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Device ID (UUID) of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlVPDMachineType | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Model Type/Model of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlVPDModel | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Model Type/Model of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlVPDSerialNo | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Serial Number of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlVPDFRUNo | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The FRU Number of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlVPDPartNo | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Part Number of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlCacheMdlStatus | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.13 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Cache Model Status of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlCacheMdlMemSize | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.14 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Cache Model Memory Size of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlCacheMdlSerialNo | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.15 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Cache Model Serial Number of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlPCISlotNo | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.16 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The PCI Slot Number of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlPCIBusNo | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.17 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The PCI Bus Number of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlPCIDevNo | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.18 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The PCI Device Number of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlPCIFuncNo | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.19 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The PCI Function Number of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlPCIDevID | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.20 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Device ID of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlPCISubDevID | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.21 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Subsystem Device ID of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatBCKProdName | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.22 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Product Name of Battery Backup of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatBCKManufacture | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.23 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Manufacture of Battery Backup of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatBCKStatus | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.24 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Status of Battery Backup of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatBCKType | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.25 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Battery Type of Battery Backup of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatBCKChem | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.26 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Chemistry of Battery Backup of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatBCKSerialNo | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.27 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Serial Number of Battery Backup of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatBCKChgCap | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.28 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Charge Capacity of Battery Backup of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatBCKFirmware | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.29 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Firmware Info of Battery Backup of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatBCKDgnVoltage | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.30 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Designed Voltage of Battery Backup of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatBCKVoltage | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.31 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Voltage of Battery Backup of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatCurrent | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.32 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Current of Battery Backup of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatBCKDgnChgCap | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.33 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Design Charge Capacity of Battery Backup of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlBatBCKCrtTemp | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.34 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Current degree Celsius temperature of Battery Backup of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlFWNames | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.35 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory All the Firmware Names of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlPortDetails | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.36 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory All the Port Details of a particular RAID controller, including Port Address and Port Controller Type. | |||||||||||||||||||||
| CraidCtrlStoragepools | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.37 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The storage pools list of a particular RAID controller. | |||||||||||||||||||||
| CraidCtrlDrives | 1.3.6.1.4.1.19046.11.1.1.13.1.2.1.38 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Physical drives list of a particular RAID controller. | |||||||||||||||||||||
| TraidDriveTable | 1.3.6.1.4.1.19046.11.1.1.13.1.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Logic Storage RAID Drive information. | |||||||||||||||||||||
| RraidDriveEntry | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1 | NA | mandatory | ||||||||||||||||||
| CraidDriveIndex | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This column is used to identify a particular RAID drive. | |||||||||||||||||||||
| CraidDriveName | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory A particular drive name. | |||||||||||||||||||||
| CraidDriveVPDProdName | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Product Name of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveState | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The State of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveSlotNo | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Slot No. of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveDeviceID | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Device ID of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveDiskType | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Disk Type of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveMediaType | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Media Type of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveSpeed | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Speed of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveCurTemp | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Current degree Celsius temperature of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveHealthStataus | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Health Status of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveCapacity | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Capacity of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveVPDManufacture | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.13 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Manufacture of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveEnclosureID | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.14 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Enclosure ID of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveVPDMachineType | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.15 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Machine type of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveVPDModel | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.16 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Model of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveVPDSerialNo | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.17 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Serial No. of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveVPDFRUNo | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.18 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The FRU No. of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveVPDPartNo | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.19 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Part No. of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveFWNames | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.20 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory All the Firmware Names of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveRotationRate | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.21 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Rotation Rate of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveMediaErrCnt | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.22 | Gauge32 | RO | mandatory | |||||||||||||||||
column · Gauge32 · read-only · mandatory The Media Error Count of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveOtherErrCnt | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.23 | Gauge32 | RO | mandatory | |||||||||||||||||
column · Gauge32 · read-only · mandatory The Other Error Count of a particular RAID drive. | |||||||||||||||||||||
| CraidDrivePredFailCnt | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.24 | Gauge32 | RO | mandatory | |||||||||||||||||
column · Gauge32 · read-only · mandatory The Predication Fail Count of a particular RAID drive. | |||||||||||||||||||||
| CraidDriveRemainingLife | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.25 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Remaining life of a particular RAID drive. It is available only for SSD Drive. | |||||||||||||||||||||
| CraidDriveFdeCapable | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.26 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates Full Disk Encryption Capable of a particular RAID drive.
| |||||||||||||||||||||
| CraidDriveSecured | 1.3.6.1.4.1.19046.11.1.1.13.1.3.1.27 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates Secured status of a particular RAID drive.
| |||||||||||||||||||||
| TraidControllerFirmwareTable | 1.3.6.1.4.1.19046.11.1.1.13.1.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Logic Storage RAID Controller Firmware information. | |||||||||||||||||||||
| RraidControllerFirmwareEntry | 1.3.6.1.4.1.19046.11.1.1.13.1.4.1 | NA | mandatory | ||||||||||||||||||
| CraidControllerFirmwareIndex | 1.3.6.1.4.1.19046.11.1.1.13.1.4.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This column is used to identify a particular RAID Controller firmware. | |||||||||||||||||||||
| CraidControllerFirmwareName | 1.3.6.1.4.1.19046.11.1.1.13.1.4.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Name of a particular RAID Controller firmware. | |||||||||||||||||||||
| CraidControllerFirmwareCtrlName | 1.3.6.1.4.1.19046.11.1.1.13.1.4.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The controller name of the firmwares. | |||||||||||||||||||||
| CraidControllerFirmwareDescription | 1.3.6.1.4.1.19046.11.1.1.13.1.4.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Description of a particular RAID Controller firmware. | |||||||||||||||||||||
| CraidControllerFirmwareManufacture | 1.3.6.1.4.1.19046.11.1.1.13.1.4.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Manufacture of a particular RAID Controller firmware. | |||||||||||||||||||||
| CraidControllerFirmwareVersion | 1.3.6.1.4.1.19046.11.1.1.13.1.4.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Version of a particular RAID Controller firmware. | |||||||||||||||||||||
| CraidControllerFirmwareReleaseDate | 1.3.6.1.4.1.19046.11.1.1.13.1.4.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Release Date of a particular RAID Controller firmware. | |||||||||||||||||||||
| TraidDriveFirmwareTable | 1.3.6.1.4.1.19046.11.1.1.13.1.5 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Logic Storage RAID Drive Firmware information. | |||||||||||||||||||||
| RraidDriveFirmwareEntry | 1.3.6.1.4.1.19046.11.1.1.13.1.5.1 | NA | mandatory | ||||||||||||||||||
| CraidDriveFirmwareIndex | 1.3.6.1.4.1.19046.11.1.1.13.1.5.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This column is used to identify a particular RAID Drive firmware. | |||||||||||||||||||||
| CraidDriveFirmwareName | 1.3.6.1.4.1.19046.11.1.1.13.1.5.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Name of a particular RAID Drive firmware. | |||||||||||||||||||||
| CraidDriveFirmwareDriveName | 1.3.6.1.4.1.19046.11.1.1.13.1.5.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The drive name of the firmwares. | |||||||||||||||||||||
| CraidDriveFirmwareDescription | 1.3.6.1.4.1.19046.11.1.1.13.1.5.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Description of a particular RAID Drive firmware. | |||||||||||||||||||||
| CraidDriveFirmwareManufacture | 1.3.6.1.4.1.19046.11.1.1.13.1.5.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Manufacture of a particular RAID Drive firmware. | |||||||||||||||||||||
| CraidDriveFirmwareVersion | 1.3.6.1.4.1.19046.11.1.1.13.1.5.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Version of a particular RAID Drive firmware. | |||||||||||||||||||||
| CraidDriveFirmwareReleaseDate | 1.3.6.1.4.1.19046.11.1.1.13.1.5.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Release Date of a particular RAID Drive firmware. | |||||||||||||||||||||
| TraidStoragepoolTable | 1.3.6.1.4.1.19046.11.1.1.13.1.6 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Logic Storage RAID Storagepool information. | |||||||||||||||||||||
| RraidStoragepoolEntry | 1.3.6.1.4.1.19046.11.1.1.13.1.6.1 | NA | mandatory | ||||||||||||||||||
| CraidStoragepoolIndex | 1.3.6.1.4.1.19046.11.1.1.13.1.6.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This column is used to identify a particular RAID storagepool. | |||||||||||||||||||||
| CraidStoragepoolName | 1.3.6.1.4.1.19046.11.1.1.13.1.6.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The name of a particular RAID storagepool. | |||||||||||||||||||||
| CraidStoragepoolControllerName | 1.3.6.1.4.1.19046.11.1.1.13.1.6.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The controller name of the storagepool. | |||||||||||||||||||||
| CraidStoragepoolState | 1.3.6.1.4.1.19046.11.1.1.13.1.6.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The RAID State of a particular RAID storagepool. | |||||||||||||||||||||
| CraidStoragepoolCapacity | 1.3.6.1.4.1.19046.11.1.1.13.1.6.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Capacity of a particular RAID storagepool, including total capacity and free capacity. | |||||||||||||||||||||
| CraidStoragepoolVols | 1.3.6.1.4.1.19046.11.1.1.13.1.6.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The volumes list of a particular RAID storagepool. | |||||||||||||||||||||
| CraidStoragepoolDrives | 1.3.6.1.4.1.19046.11.1.1.13.1.6.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The physical drives list of a particular RAID storagepool. | |||||||||||||||||||||
| TraidVolumeTable | 1.3.6.1.4.1.19046.11.1.1.13.1.7 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Logic Storage RAID Volume information. | |||||||||||||||||||||
| RraidVolumeEntry | 1.3.6.1.4.1.19046.11.1.1.13.1.7.1 | NA | mandatory | ||||||||||||||||||
| CraidVolumeIndex | 1.3.6.1.4.1.19046.11.1.1.13.1.7.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This column is used to identify a particular RAID volume. | |||||||||||||||||||||
| CraidVolumeName | 1.3.6.1.4.1.19046.11.1.1.13.1.7.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Name of a particular RAID volume. | |||||||||||||||||||||
| CraidVolumeControllerName | 1.3.6.1.4.1.19046.11.1.1.13.1.7.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The controller name of the volume. | |||||||||||||||||||||
| CraidVolumeStatus | 1.3.6.1.4.1.19046.11.1.1.13.1.7.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Status of a particular RAID volume. | |||||||||||||||||||||
| CraidVolumeCapacity | 1.3.6.1.4.1.19046.11.1.1.13.1.7.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Capacity of a particular RAID volume. | |||||||||||||||||||||
| CraidVolumeStripSize | 1.3.6.1.4.1.19046.11.1.1.13.1.7.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The strip size of the RAID volume. | |||||||||||||||||||||
| CraidVolumeBootable | 1.3.6.1.4.1.19046.11.1.1.13.1.7.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Whether the RAID volume is bootable. | |||||||||||||||||||||
| Nadapters | 1.3.6.1.4.1.19046.11.1.1.14 | ||||||||||||||||||||
| SadapterOOBCapable | 1.3.6.1.4.1.19046.11.1.1.14.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory If adapterOOBCapable is disabled, all the adapter information is not available.
| |||||||||||||||||||||
| TadapterGenericTable | 1.3.6.1.4.1.19046.11.1.1.14.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of all adapters generic information | |||||||||||||||||||||
| RadapterGenericEntry | 1.3.6.1.4.1.19046.11.1.1.14.2.1 | NA | mandatory | ||||||||||||||||||
| CadapterGenericIndex | 1.3.6.1.4.1.19046.11.1.1.14.2.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This column is used to identify a particular PCI adapter. | |||||||||||||||||||||
| CadapterGenericVPDProdName | 1.3.6.1.4.1.19046.11.1.1.14.2.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Product Name of a particular PCI adapter. And if the Product Name contains PFA, PFA is in HEX. | |||||||||||||||||||||
| CadapterGenericSlotNo | 1.3.6.1.4.1.19046.11.1.1.14.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This Slot No. of a particular PCI adapter | |||||||||||||||||||||
| CadapterGenericLocation | 1.3.6.1.4.1.19046.11.1.1.14.2.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Location of a particular PCI adapter. | |||||||||||||||||||||
| CadapterGenericCardInterface | 1.3.6.1.4.1.19046.11.1.1.14.2.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Card Interface of a particular PCI adapter. | |||||||||||||||||||||
| TadapterNetworkFunctionTable | 1.3.6.1.4.1.19046.11.1.1.14.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Network Function information. | |||||||||||||||||||||
| RadapterNetworkFunctionEntry | 1.3.6.1.4.1.19046.11.1.1.14.3.1 | NA | mandatory | ||||||||||||||||||
| CadapterNetworkFunctionIndex | 1.3.6.1.4.1.19046.11.1.1.14.3.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This column is used to identify a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionNetworkVPDProdName | 1.3.6.1.4.1.19046.11.1.1.14.3.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Product Name and PFA of a particular network function and PFA is in HEX. | |||||||||||||||||||||
| CadapterNetworkFunctionAdapterVPDProdName | 1.3.6.1.4.1.19046.11.1.1.14.3.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Product Name of a particular adapter providing this function. And if the Product Name contains PFA, PFA is in HEX. | |||||||||||||||||||||
| CadapterNetworkFunctionNetworkVPDManufacturer | 1.3.6.1.4.1.19046.11.1.1.14.3.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Manufacturer of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionNetworkVPDUUID | 1.3.6.1.4.1.19046.11.1.1.14.3.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The UUID of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionNetworkVPDModel | 1.3.6.1.4.1.19046.11.1.1.14.3.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Model of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionNetworkVPDSerialNo | 1.3.6.1.4.1.19046.11.1.1.14.3.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Serial No. of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionNetworkVPDFRUNo | 1.3.6.1.4.1.19046.11.1.1.14.3.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The FRU No. of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionNetworkVPDPartNo | 1.3.6.1.4.1.19046.11.1.1.14.3.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Part No. of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionFoDUID | 1.3.6.1.4.1.19046.11.1.1.14.3.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The FoD UID of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionSupportHotPlug | 1.3.6.1.4.1.19046.11.1.1.14.3.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether the network function supports hot plug.
| |||||||||||||||||||||
| CadapterNetworkFunctionPhysicalPortNumber | 1.3.6.1.4.1.19046.11.1.1.14.3.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Physical Port Number of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionMaxPortNumber | 1.3.6.1.4.1.19046.11.1.1.14.3.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Max Port Number of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionPortNumber | 1.3.6.1.4.1.19046.11.1.1.14.3.1.14 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Port Number of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionMaxDataWidth | 1.3.6.1.4.1.19046.11.1.1.14.3.1.15 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Maximum Data Width in Gbps of a particular network funtion. | |||||||||||||||||||||
| CadapterNetworkFunctionPackageType | 1.3.6.1.4.1.19046.11.1.1.14.3.1.16 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Package Type of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionPCIBusNo | 1.3.6.1.4.1.19046.11.1.1.14.3.1.17 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The PCI Bus No. of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionPCIDevNo | 1.3.6.1.4.1.19046.11.1.1.14.3.1.18 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The PCI Device No. of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionPCIFuncNo | 1.3.6.1.4.1.19046.11.1.1.14.3.1.19 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The PCI Function No. of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionPCIVendorId | 1.3.6.1.4.1.19046.11.1.1.14.3.1.20 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Vendor ID of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionPCIDevId | 1.3.6.1.4.1.19046.11.1.1.14.3.1.21 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Device ID of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionPCIDevType | 1.3.6.1.4.1.19046.11.1.1.14.3.1.22 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Device Type of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionPCIRevId | 1.3.6.1.4.1.19046.11.1.1.14.3.1.23 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Revision ID of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionPCISubVendorId | 1.3.6.1.4.1.19046.11.1.1.14.3.1.24 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Subsystem Vendor ID of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionPCISubDevId | 1.3.6.1.4.1.19046.11.1.1.14.3.1.25 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Subsystem Device ID of a particular network function. | |||||||||||||||||||||
| CadapterNetworkFunctionPCISlotDesignation | 1.3.6.1.4.1.19046.11.1.1.14.3.1.26 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Slot Designation of a particular network function. | |||||||||||||||||||||
| TadapterNetworkPortTable | 1.3.6.1.4.1.19046.11.1.1.14.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Ports of Network Function information. | |||||||||||||||||||||
| RadapterNetworkPortEntry | 1.3.6.1.4.1.19046.11.1.1.14.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Ports of Network Function information entry. | |||||||||||||||||||||
| CadapterNetworkPortIndex | 1.3.6.1.4.1.19046.11.1.1.14.4.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This column is used to identify a particular network port. | |||||||||||||||||||||
| CadapterNetworkPortNetworkVPDProdName | 1.3.6.1.4.1.19046.11.1.1.14.4.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Product Name and PFA of the network function for this port and PFA is in HEX. | |||||||||||||||||||||
| CadapterNetworkPortPhyPortNo | 1.3.6.1.4.1.19046.11.1.1.14.4.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Physical Port No. in the network function for this port. | |||||||||||||||||||||
| CadapterNetworkPortPhyPortConnector | 1.3.6.1.4.1.19046.11.1.1.14.4.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Physical Port Connector Layout in the network function for this port. | |||||||||||||||||||||
| CadapterNetworkPortPhyPortBurnedinAddress | 1.3.6.1.4.1.19046.11.1.1.14.4.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Physical Permanent (burned-In) Address of a particular network port. | |||||||||||||||||||||
| CadapterNetworkPortNo | 1.3.6.1.4.1.19046.11.1.1.14.4.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Port No. of this network port in the network function. | |||||||||||||||||||||
| CadapterNetworkPortMaxDataSize | 1.3.6.1.4.1.19046.11.1.1.14.4.1.7 | Gauge32 | RO | mandatory | |||||||||||||||||
column · Gauge32 · read-only · mandatory The Port Max Data Size of this network port in the network function. | |||||||||||||||||||||
| CadapterNetworkPortPermanentAddress | 1.3.6.1.4.1.19046.11.1.1.14.4.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Permanent Address of a particular network port. | |||||||||||||||||||||
| CadapterNetworkPortNetworkAddress | 1.3.6.1.4.1.19046.11.1.1.14.4.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Network Address of a particular network port. | |||||||||||||||||||||
| CadapterNetworkPortLinkTechnology | 1.3.6.1.4.1.19046.11.1.1.14.4.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Link Technology of a particular network port. | |||||||||||||||||||||
| CadapterNetworkPortvNICMode | 1.3.6.1.4.1.19046.11.1.1.14.4.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory If the logical port vNIC mode is Virtual Fabric mode, Switch Independent mode, or Unified Fabric Protocol mode, this column returns 1(enabled), otherwise, the columen returns 0(disabled) | |||||||||||||||||||||
| CadapterNetworkPortMaxSpeed | 1.3.6.1.4.1.19046.11.1.1.14.4.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Maximum Bandwidth in Gbps of a particular network port. | |||||||||||||||||||||
| CadapterNetworkPortProtocolType | 1.3.6.1.4.1.19046.11.1.1.14.4.1.13 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Protocol Type of a particular network port. | |||||||||||||||||||||
| CadapterNetworkPortCurrentProtocol | 1.3.6.1.4.1.19046.11.1.1.14.4.1.14 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Current Work Protocol of a particular network port. | |||||||||||||||||||||
| CadapterNetworkPortFCoEPermanentAddress | 1.3.6.1.4.1.19046.11.1.1.14.4.1.15 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The FCoE Permanent Address of a particular network port. | |||||||||||||||||||||
| CadapterNetworkPortFCoENetworkAddress | 1.3.6.1.4.1.19046.11.1.1.14.4.1.16 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The FCoE Network Address of a particular network port. | |||||||||||||||||||||
| CadapterNetworkPortConnectionType | 1.3.6.1.4.1.19046.11.1.1.14.4.1.17 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Connection Type of a particular network port if its current work protocol is FC or FCoE. | |||||||||||||||||||||
| CadapterNetworkPortRole | 1.3.6.1.4.1.19046.11.1.1.14.4.1.18 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Port Role of a particular network port if its current work protocol is FC or FCoE. | |||||||||||||||||||||
| CadapterNetworkPortTargetRelativePortNo | 1.3.6.1.4.1.19046.11.1.1.14.4.1.19 | Gauge32 | RO | mandatory | |||||||||||||||||
column · Gauge32 · read-only · mandatory The Target Relative Port No. of a particular network port if its current work protocol is FC or FCoE. | |||||||||||||||||||||
| CadapterNetworkPortPhyPortLinkStatus | 1.3.6.1.4.1.19046.11.1.1.14.4.1.20 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Physical Port Link Status in the network function for this port. | |||||||||||||||||||||
| CadapterNetworkPortPhyPortLinkSpeed | 1.3.6.1.4.1.19046.11.1.1.14.4.1.21 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Physical Port Link Speed in the network function for this port. | |||||||||||||||||||||
| TadapterGPUFunctionTable | 1.3.6.1.4.1.19046.11.1.1.14.5 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of GPU Function information. | |||||||||||||||||||||
| RadapterGPUFunctionEntry | 1.3.6.1.4.1.19046.11.1.1.14.5.1 | NA | mandatory | ||||||||||||||||||
| CadapterGPUFunctionIndex | 1.3.6.1.4.1.19046.11.1.1.14.5.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This column is used to identify a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionGpuVPDProdName | 1.3.6.1.4.1.19046.11.1.1.14.5.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Product Name and PFA of a particular GPU function and PFA is in HEX. | |||||||||||||||||||||
| CadapterGPUFunctionAdapterVPDProdName | 1.3.6.1.4.1.19046.11.1.1.14.5.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Product Name of a particular adapter providing this function. And if the Product Name contains PFA, PFA is in HEX. | |||||||||||||||||||||
| CadapterGPUFunctionGpuVPDManufacturer | 1.3.6.1.4.1.19046.11.1.1.14.5.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Manufacturer of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionGpuVPDUUID | 1.3.6.1.4.1.19046.11.1.1.14.5.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The UUID of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionGpuVPDModel | 1.3.6.1.4.1.19046.11.1.1.14.5.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Model of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionGpuVPDSerialNo | 1.3.6.1.4.1.19046.11.1.1.14.5.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Serial No. of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionGpuVPDFRUNo | 1.3.6.1.4.1.19046.11.1.1.14.5.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The FRU No. of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionGpuVPDPartNo | 1.3.6.1.4.1.19046.11.1.1.14.5.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Part No. of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionFoDUID | 1.3.6.1.4.1.19046.11.1.1.14.5.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The FoD UID of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionSupportHotPlug | 1.3.6.1.4.1.19046.11.1.1.14.5.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether the GPU function supports hot plug.
| |||||||||||||||||||||
| CadapterGPUFunctionVideoMemorySize | 1.3.6.1.4.1.19046.11.1.1.14.5.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Video Memory Size of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionVideoMemoryType | 1.3.6.1.4.1.19046.11.1.1.14.5.1.13 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Video Memory Type of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionChipNumber | 1.3.6.1.4.1.19046.11.1.1.14.5.1.14 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Chip Number of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionMaxDataWidth | 1.3.6.1.4.1.19046.11.1.1.14.5.1.15 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Maximum Data Width in Gbps of a particular GPU funtion. | |||||||||||||||||||||
| CadapterGPUFunctionPackageType | 1.3.6.1.4.1.19046.11.1.1.14.5.1.16 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Package Type of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionPCIBusNo | 1.3.6.1.4.1.19046.11.1.1.14.5.1.17 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The PCI Bus No. of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionPCIDevNo | 1.3.6.1.4.1.19046.11.1.1.14.5.1.18 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The PCI Device No. of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionPCIFuncNo | 1.3.6.1.4.1.19046.11.1.1.14.5.1.19 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The PCI Function No. of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionPCIVendorId | 1.3.6.1.4.1.19046.11.1.1.14.5.1.20 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Vendor ID of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionPCIDevId | 1.3.6.1.4.1.19046.11.1.1.14.5.1.21 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Device ID of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionPCIDevType | 1.3.6.1.4.1.19046.11.1.1.14.5.1.22 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Device Type of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionPCIRevId | 1.3.6.1.4.1.19046.11.1.1.14.5.1.23 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Revision ID of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionPCISubVendorId | 1.3.6.1.4.1.19046.11.1.1.14.5.1.24 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Subsystem Vendor ID of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionPCISubDevId | 1.3.6.1.4.1.19046.11.1.1.14.5.1.25 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Subsystem Device ID of a particular GPU function. | |||||||||||||||||||||
| CadapterGPUFunctionPCISlotDesignation | 1.3.6.1.4.1.19046.11.1.1.14.5.1.26 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Slot Designation of a particular GPU function. | |||||||||||||||||||||
| TadapterGPUChipTable | 1.3.6.1.4.1.19046.11.1.1.14.6 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Chips of GPU Function information. | |||||||||||||||||||||
| RadapterGPUChipEntry | 1.3.6.1.4.1.19046.11.1.1.14.6.1 | NA | mandatory | ||||||||||||||||||
| CadapterGPUChipIndex | 1.3.6.1.4.1.19046.11.1.1.14.6.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This column is used to identify a particular GPU chip | |||||||||||||||||||||
| CadapterGPUChipGpuVPDProdName | 1.3.6.1.4.1.19046.11.1.1.14.6.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Product Name and PFA of the GPU function for this chip and PFA is in HEX. | |||||||||||||||||||||
| CadapterGPUChipNo | 1.3.6.1.4.1.19046.11.1.1.14.6.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Index of the GPU chip in the GPU adapter. | |||||||||||||||||||||
| CadapterGPUChipName | 1.3.6.1.4.1.19046.11.1.1.14.6.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Name of a particular GPU chip. | |||||||||||||||||||||
| CadapterGPUChipFamily | 1.3.6.1.4.1.19046.11.1.1.14.6.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Family Name of a particular GPU chip. | |||||||||||||||||||||
| CadapterGPUChipManufacturer | 1.3.6.1.4.1.19046.11.1.1.14.6.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Manufacturer of a particular GPU chip. | |||||||||||||||||||||
| CadapterGPUChipCoresEnabled | 1.3.6.1.4.1.19046.11.1.1.14.6.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether enable cores of a particular GPU chip. | |||||||||||||||||||||
| CadapterGPUChipMaxClockSpeed | 1.3.6.1.4.1.19046.11.1.1.14.6.1.8 | Gauge32 | RO | mandatory | |||||||||||||||||
column · Gauge32 · read-only · mandatory The Maximum Clock Speed in MHz of a particular GPU chip. | |||||||||||||||||||||
| CadapterGPUChipExtBusClockSpeed | 1.3.6.1.4.1.19046.11.1.1.14.6.1.9 | Gauge32 | RO | mandatory | |||||||||||||||||
column · Gauge32 · read-only · mandatory The External Bus Clock Speed in MHz of a particular GPU chip. | |||||||||||||||||||||
| CadapterGPUChipAddressWidth | 1.3.6.1.4.1.19046.11.1.1.14.6.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Address Width of a particular GPU chip. | |||||||||||||||||||||
| CadapterGPUChipDataWidth | 1.3.6.1.4.1.19046.11.1.1.14.6.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Data Width of a particular GPU chip. | |||||||||||||||||||||
| CadapterGPUChipFormFactor | 1.3.6.1.4.1.19046.11.1.1.14.6.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Form Factor of a particular GPU chip. | |||||||||||||||||||||
| CadapterGPUChipModel | 1.3.6.1.4.1.19046.11.1.1.14.6.1.13 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Model of a particular GPU chip. | |||||||||||||||||||||
| CadapterGPUChipSerialNo | 1.3.6.1.4.1.19046.11.1.1.14.6.1.14 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Serial No. of a particular GPU chip. | |||||||||||||||||||||
| CadapterGPUChipFRUNo | 1.3.6.1.4.1.19046.11.1.1.14.6.1.15 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The FRU No. of a particular GPU chip. | |||||||||||||||||||||
| CadapterGPUChipPartNo | 1.3.6.1.4.1.19046.11.1.1.14.6.1.16 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Part No. of a particular GPU chip. | |||||||||||||||||||||
| CadapterGPUChipUniqueID | 1.3.6.1.4.1.19046.11.1.1.14.6.1.17 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Unique ID of a particular GPU chip. | |||||||||||||||||||||
| TadapterRAIDFunctionTable | 1.3.6.1.4.1.19046.11.1.1.14.7 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of RAID Function information. | |||||||||||||||||||||
| RadapterRAIDFunctionEntry | 1.3.6.1.4.1.19046.11.1.1.14.7.1 | NA | mandatory | ||||||||||||||||||
| CadapterRAIDFunctionIndex | 1.3.6.1.4.1.19046.11.1.1.14.7.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This column is used to identify a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionRaidVPDProdName | 1.3.6.1.4.1.19046.11.1.1.14.7.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Product Name and PFA of a particular RAID function and PFA is in HEX. | |||||||||||||||||||||
| CadapterRAIDFunctionAdapterVPDProdName | 1.3.6.1.4.1.19046.11.1.1.14.7.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Product Name of a particular adapter providing this function. And if the Product Name contains PFA, PFA is in HEX. | |||||||||||||||||||||
| CadapterRAIDFunctionRaidVPDManufacturer | 1.3.6.1.4.1.19046.11.1.1.14.7.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Manufacturer of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionRaidVPDUUID | 1.3.6.1.4.1.19046.11.1.1.14.7.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The UUID of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionRaidVPDModel | 1.3.6.1.4.1.19046.11.1.1.14.7.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Model of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionRaidVPDSerialNo | 1.3.6.1.4.1.19046.11.1.1.14.7.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Serial No. of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionRaidVPDFRUNo | 1.3.6.1.4.1.19046.11.1.1.14.7.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The FRU No. of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionRaidVPDPartNo | 1.3.6.1.4.1.19046.11.1.1.14.7.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Part No. of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionFoDUID | 1.3.6.1.4.1.19046.11.1.1.14.7.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The FoD UID of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionSupportHotPlug | 1.3.6.1.4.1.19046.11.1.1.14.7.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether the RAID function supports hot plug.
| |||||||||||||||||||||
| CadapterRAIDFunctionMaxDataWidth | 1.3.6.1.4.1.19046.11.1.1.14.7.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Maximum Data Width in Gbps of a particular RAID funtion. | |||||||||||||||||||||
| CadapterRAIDFunctionPackageType | 1.3.6.1.4.1.19046.11.1.1.14.7.1.13 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Package Type of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionPCIBusNo | 1.3.6.1.4.1.19046.11.1.1.14.7.1.14 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The PCI Bus No. of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionPCIDevNo | 1.3.6.1.4.1.19046.11.1.1.14.7.1.15 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The PCI Device No. of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionPCIFuncNo | 1.3.6.1.4.1.19046.11.1.1.14.7.1.16 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The PCI Function No. of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionPCIVendorId | 1.3.6.1.4.1.19046.11.1.1.14.7.1.17 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Vendor ID of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionPCIDevId | 1.3.6.1.4.1.19046.11.1.1.14.7.1.18 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Device ID of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionPCIDevType | 1.3.6.1.4.1.19046.11.1.1.14.7.1.19 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Device Type of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionPCIRevId | 1.3.6.1.4.1.19046.11.1.1.14.7.1.20 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Revision ID of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionPCISubVendorId | 1.3.6.1.4.1.19046.11.1.1.14.7.1.21 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Subsystem Vendor ID of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionPCISubDevId | 1.3.6.1.4.1.19046.11.1.1.14.7.1.22 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Subsystem Device ID of a particular RAID function. | |||||||||||||||||||||
| CadapterRAIDFunctionPCISlotDesignation | 1.3.6.1.4.1.19046.11.1.1.14.7.1.23 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PCI Slot Designation of a particular RAID function. | |||||||||||||||||||||
| TadapterFirmwareTable | 1.3.6.1.4.1.19046.11.1.1.14.8 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of PCI Function Firmware information. | |||||||||||||||||||||
| RadapterFirmwareEntry | 1.3.6.1.4.1.19046.11.1.1.14.8.1 | NA | mandatory | ||||||||||||||||||
| CadapterFwIndex | 1.3.6.1.4.1.19046.11.1.1.14.8.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This column is used to identify a particular function firmware. | |||||||||||||||||||||
| CadapterFwFunctionVPDProdName | 1.3.6.1.4.1.19046.11.1.1.14.8.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Product Name and PFA of a particular function for this firmware and PFA is in HEX. | |||||||||||||||||||||
| CadapterFwName | 1.3.6.1.4.1.19046.11.1.1.14.8.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The name of a particular PCI function firmware. | |||||||||||||||||||||
| CadapterFwClassification | 1.3.6.1.4.1.19046.11.1.1.14.8.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The classification of a particular PCI function firmware. | |||||||||||||||||||||
| CadapterFwDescription | 1.3.6.1.4.1.19046.11.1.1.14.8.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The description of a particular PCI function firmware. | |||||||||||||||||||||
| CadapterFwManufacture | 1.3.6.1.4.1.19046.11.1.1.14.8.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The manufacturer of a particular PCI function firmware. | |||||||||||||||||||||
| CadapterFwVersion | 1.3.6.1.4.1.19046.11.1.1.14.8.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The version of a particular PCI function firmware. | |||||||||||||||||||||
| CadapterFwReleaseDate | 1.3.6.1.4.1.19046.11.1.1.14.8.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The release date of a particular PCI function firmware. | |||||||||||||||||||||
| CadapterFwSoftwareID | 1.3.6.1.4.1.19046.11.1.1.14.8.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Software ID of a particular PCI function firmware. | |||||||||||||||||||||
| NerrorLogs | 1.3.6.1.4.1.19046.11.1.2 | ||||||||||||||||||||
| NeventLog | 1.3.6.1.4.1.19046.11.1.2.1 | ||||||||||||||||||||
| TeventLogTable | 1.3.6.1.4.1.19046.11.1.2.1.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of event logs. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| ReventLogEntry | 1.3.6.1.4.1.19046.11.1.2.1.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Event log entries. View as a table and not as individual entries for consistent results.
| |||||||||||||||||||||
| CeventLogIndex | 1.3.6.1.4.1.19046.11.1.2.1.1.1.1 | INTEGER (1..1000000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000000) · read-only · mandatory Event log index number. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CeventLogString | 1.3.6.1.4.1.19046.11.1.2.1.1.1.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory Contains a string of information to detail the event. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CeventLogSeverity | 1.3.6.1.4.1.19046.11.1.2.1.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Contains a information to detail the severity of the event. View as a table and not as individual entries for consistent results.
| |||||||||||||||||||||
| CeventLogDate | 1.3.6.1.4.1.19046.11.1.2.1.1.1.4 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory The Date of the Event occured. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| CeventLogTime | 1.3.6.1.4.1.19046.11.1.2.1.1.1.5 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory The Time of the Event occured. View as a table and not as individual entries for consistent results. | |||||||||||||||||||||
| NconfigureSP | 1.3.6.1.4.1.19046.11.1.3 | ||||||||||||||||||||
| NremoteAccessConfig | 1.3.6.1.4.1.19046.11.1.3.1 | ||||||||||||||||||||
| NgeneralRemoteCfg | 1.3.6.1.4.1.19046.11.1.3.1.1 | ||||||||||||||||||||
| SremoteAlertRetryDelay | 1.3.6.1.4.1.19046.11.1.3.1.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Number in seconds to delay between retries if sending a remote alert is unsuccessful.
| |||||||||||||||||||||
| SremoteAlertRetryCount | 1.3.6.1.4.1.19046.11.1.3.1.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Number of additional times a remote alert will be retried if not succesfully sent. A value of zero indicates no retries will be attempted.
| |||||||||||||||||||||
| SremoteAlertEntryDelay | 1.3.6.1.4.1.19046.11.1.3.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Number in seconds to delay between entries if sending a remote alert is unsuccessful.
| |||||||||||||||||||||
| SsnmpCriticalAlerts | 1.3.6.1.4.1.19046.11.1.3.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory If Enabled,criticalAlerts will be sent to SNMP, else critical alerts will not be sent.
| |||||||||||||||||||||
| SsnmpWarningAlerts | 1.3.6.1.4.1.19046.11.1.3.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory If Enabled,warningAlerts will be sent to SNMP , else warning alerts will not be sent.
| |||||||||||||||||||||
| SsnmpSystemAlerts | 1.3.6.1.4.1.19046.11.1.3.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory If Enabled,systemAlerts will be sent to SNMP , else system alerts will not be sent.
| |||||||||||||||||||||
| SremoteAccessTamperDelay | 1.3.6.1.4.1.19046.11.1.3.1.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Number in minutes to prohibit a remote login attempt after more than maximum login attempts have failed. The minimum value is 0 and the maximum value is 2880 minute. The default value is 60 minutes. | |||||||||||||||||||||
| SuserAuthenticationMethod | 1.3.6.1.4.1.19046.11.1.3.1.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Use this field to specify how users attempting to login should be authenticated.
There are two methods:
Local authentication. Userid and password are verified by searching the list
of users locally configured under Local Login Profiles.
LDAP based authentication. Users are authenticated via a remote LDAP server.
One or both authentication methods can be selected. If both methods should be
used, the order must be specified.
| |||||||||||||||||||||
| SwebInactivityTimeout | 1.3.6.1.4.1.19046.11.1.3.1.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The amount of time, in minutes, that a user session established with the management server can be inactive before the user is logged out. The minimum value is 0 and the maximum value is 1440 minutes. The default value is 20 minutes. If the value is 0, web session never expire. | |||||||||||||||||||||
| NsnmpAlertFilters | 1.3.6.1.4.1.19046.11.1.3.1.1.10 | ||||||||||||||||||||
| SsafSpTrapTempC | 1.3.6.1.4.1.19046.11.1.3.1.1.10.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Critical Alert: Temperature threshold exceeded.
| |||||||||||||||||||||
| SsafSpTrapVoltC | 1.3.6.1.4.1.19046.11.1.3.1.1.10.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Critical Alert: Voltage threshold exceeded.
| |||||||||||||||||||||
| SsafSpTrapPowerC | 1.3.6.1.4.1.19046.11.1.3.1.1.10.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Critical Alert: Power failure.
| |||||||||||||||||||||
| SsafSpTrapHdC | 1.3.6.1.4.1.19046.11.1.3.1.1.10.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Critical Alert: Hard disk drive failure.
| |||||||||||||||||||||
| SsafSpTrapFanC | 1.3.6.1.4.1.19046.11.1.3.1.1.10.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Critical Alert: Single Fan failure.
| |||||||||||||||||||||
| SsafSpTrapIhcC | 1.3.6.1.4.1.19046.11.1.3.1.1.10.7 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Critical Alert: Incompatible hardware configuration.
| |||||||||||||||||||||
| SsafSpTrapCPUC | 1.3.6.1.4.1.19046.11.1.3.1.1.10.8 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Critical Alert: CPU Error.
| |||||||||||||||||||||
| SsafSpTrapMemoryC | 1.3.6.1.4.1.19046.11.1.3.1.1.10.9 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Critical Alert: Memory Error.
| |||||||||||||||||||||
| SsafSpTrapRdpsC | 1.3.6.1.4.1.19046.11.1.3.1.1.10.10 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Critical Alert: Redundant Power Supply failure.
| |||||||||||||||||||||
| SsafSpTrapHardwareC | 1.3.6.1.4.1.19046.11.1.3.1.1.10.11 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Critical Alert: Other Failure - refer to Message ID for specific condition.
| |||||||||||||||||||||
| SsafSpTrapRdpsN | 1.3.6.1.4.1.19046.11.1.3.1.1.10.12 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Non-Critical Alert: Redundant Power Supply failure.
| |||||||||||||||||||||
| SsafSpTrapTempN | 1.3.6.1.4.1.19046.11.1.3.1.1.10.13 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Non-Critical Alert: Temperature threshold exceeded.
| |||||||||||||||||||||
| SsafSpTrapVoltN | 1.3.6.1.4.1.19046.11.1.3.1.1.10.14 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Non-Critical Alert: Voltage threshold exceeded.
| |||||||||||||||||||||
| SsafSpTrapPowerN | 1.3.6.1.4.1.19046.11.1.3.1.1.10.15 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Non-Critical Alert: Power.
| |||||||||||||||||||||
| SsafSpTrapFanN | 1.3.6.1.4.1.19046.11.1.3.1.1.10.16 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Non-Critical Alert: Fan Error.
| |||||||||||||||||||||
| SsafSpTrapCPUN | 1.3.6.1.4.1.19046.11.1.3.1.1.10.17 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Non-Critical Alert: Memory Error.
| |||||||||||||||||||||
| SsafSpTrapMemoryN | 1.3.6.1.4.1.19046.11.1.3.1.1.10.18 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Non-Critical Alert: Memory Error.
| |||||||||||||||||||||
| SsafSpTrapHardwareN | 1.3.6.1.4.1.19046.11.1.3.1.1.10.19 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Non-Critical Alert: Warning - refer to Message ID for specific condition.
| |||||||||||||||||||||
| SsafSpTrapRLogin | 1.3.6.1.4.1.19046.11.1.3.1.1.10.20 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Sev-Off Alert: Event Remote Login.
| |||||||||||||||||||||
| SsafSpTrapOsToS | 1.3.6.1.4.1.19046.11.1.3.1.1.10.21 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory System Alert: OS Timeout value exceeded.
| |||||||||||||||||||||
| SsafSpTrapAppS | 1.3.6.1.4.1.19046.11.1.3.1.1.10.22 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory System Alert: Application Alert. Refer to Message ID for specific condition.
| |||||||||||||||||||||
| SsafSpTrapPowerS | 1.3.6.1.4.1.19046.11.1.3.1.1.10.23 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory System Alert: Power on or off.
| |||||||||||||||||||||
| SsafSpTrapBootS | 1.3.6.1.4.1.19046.11.1.3.1.1.10.24 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory System Alert: System Boot Failure.
| |||||||||||||||||||||
| SsafSpTrapLdrToS | 1.3.6.1.4.1.19046.11.1.3.1.1.10.25 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory System Alert: OS Loader Timeout.
| |||||||||||||||||||||
| SsafSpTrapPFAS | 1.3.6.1.4.1.19046.11.1.3.1.1.10.26 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory System Alert: Predictive Failure Analysis(PFA) information.
| |||||||||||||||||||||
| SsafSpTrapSysLogS | 1.3.6.1.4.1.19046.11.1.3.1.1.10.27 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory System Alert: System Log 75% full.
| |||||||||||||||||||||
| SsafSpTrapNwChangeS | 1.3.6.1.4.1.19046.11.1.3.1.1.10.28 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory System Alert: Network change notification.
| |||||||||||||||||||||
| NcustomSecuritySettings | 1.3.6.1.4.1.19046.11.1.3.1.1.20 | ||||||||||||||||||||
| SpasswordExpirationWarningPeriod | 1.3.6.1.4.1.19046.11.1.3.1.1.20.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The amount of time, in days, before password expiration that users will begin to receive warnings about the impending expiration of the user password. The minimum value is 0 and the maximum value is the maximum password expiration period. The default value is 5 days. A value of 0 means that the users are never warned. | |||||||||||||||||||||
| SpasswordExpirationPeriod | 1.3.6.1.4.1.19046.11.1.3.1.1.20.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The amount of time, in days, that a user may use a password before it must be changed. Smaller values reduce the amount of time for attackers to guess passwords. The minimum value is 0 and the maximum value is 365 days. The default value is 90 days. A value of 0 means that the password never expire. | |||||||||||||||||||||
| SminimumPasswordReuseCycle | 1.3.6.1.4.1.19046.11.1.3.1.1.20.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The minimum number of the times that a user must enter a unique password before the user can start to reuse passwords. A higher number enhances security. The minimum value is 0 and the maximum value is 10 times. The default value is 5 times. A value of 0 means that passwords may be reused immediately. | |||||||||||||||||||||
| SminimumPasswordLength | 1.3.6.1.4.1.19046.11.1.3.1.1.20.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The minimum number of characters that can be used to specify a valid password. The minimum value is 8 characters and the maximum value is 20 characters. The default value is 8 characters. | |||||||||||||||||||||
| SdefaultAdminPasswordExpired | 1.3.6.1.4.1.19046.11.1.3.1.1.20.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory A value of 1 means that the factory default 'USERID' account password must be changed on next login. A value of 0 means that there is no such requirement. The default value is 0. | |||||||||||||||||||||
| SchangePasswordFirstAccess | 1.3.6.1.4.1.19046.11.1.3.1.1.20.8 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory A value of 1 means that a user is required to change the password when the user logs in to the management server for the first time. A value of 0 means no such requirment. The default value is 1. | |||||||||||||||||||||
| SaccountLockoutPeriod | 1.3.6.1.4.1.19046.11.1.3.1.1.20.9 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The minimum about of time, in minutes, that must pass before a user that was locked out can attempt to log back in again. The minimum value is 0 and the maximum value is 2880 minutes. The default value is 60 minutes. A value of 0 can make your system more exposed to serious denial of service attacks, where deliberate failed login attempts can leave accounts permanently locked. | |||||||||||||||||||||
| SmaxLoginFailures | 1.3.6.1.4.1.19046.11.1.3.1.1.20.10 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The maximum number of times that a user can attempt to log in with an incorrect password before the user account is locked out. The number specified for the lockout period after maximum login failures determines how long the user account is locked out. Accounts that are locked cannot be used to gain access to the system even if a valid password is provided. The maximum value is 10 times. The default value is 5 times. A value of 0 means that accounts are never locked. | |||||||||||||||||||||
| SpasswordChangeInterval | 1.3.6.1.4.1.19046.11.1.3.1.1.20.11 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The minimum about of time, in hours, that must elapse before a user may change a password again after it has been changed once. The value specified for this setting would not exceed the value specified for the password expiration period. A small value allows users to more quickly use old passwords. The range of acceptable values will be from 0 to 240 hours. The default value is 24 hours. If the value is 0, passwords may be changed immediately. | |||||||||||||||||||||
| NserialPortCfg | 1.3.6.1.4.1.19046.11.1.3.1.2 | ||||||||||||||||||||
| SportBaud | 1.3.6.1.4.1.19046.11.1.3.1.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Baud rate for the serial port.
| |||||||||||||||||||||
| SportParity | 1.3.6.1.4.1.19046.11.1.3.1.2.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Parity setting for the serial port.
| |||||||||||||||||||||
| NserialRedirect | 1.3.6.1.4.1.19046.11.1.3.1.2.3 | ||||||||||||||||||||
| SenterCLIkeySeq | 1.3.6.1.4.1.19046.11.1.3.1.2.3.1 | OCTET STRING (SIZE (0..15)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..15)) · read-only · mandatory This is the keystroke sequence used to enter the CLI.
This sequence must have at least one character. The caret symbol (^)
has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that
map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage
return). All ocurrences of ^ will be interpreted as part of a Ctrl sequence.
Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences.
The default value for this field is '^[(' i.e. ESC followed by (. | |||||||||||||||||||||
| SportStopBits | 1.3.6.1.4.1.19046.11.1.3.1.2.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Number of stop bits for the serial port.
| |||||||||||||||||||||
| SportCLImode | 1.3.6.1.4.1.19046.11.1.3.1.2.18 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Use this field to select the CLI (command line interface) mode for this port. The CLI mode disablies serial redirect, or pecifies the type of keystroke sequences to use for entering (returning to) the CLI from the system console.
| |||||||||||||||||||||
| NremoteAlertIds | 1.3.6.1.4.1.19046.11.1.3.1.3 | ||||||||||||||||||||
| TremoteAlertIdsTable | 1.3.6.1.4.1.19046.11.1.3.1.3.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of remote alert entries. This table lets you configure remote alert recipients. You can define up to 12 unique recipients. | |||||||||||||||||||||
| RremoteAlertIdsEntry | 1.3.6.1.4.1.19046.11.1.3.1.3.1.1 | NA | mandatory | ||||||||||||||||||
| CremoteAlertIdEntryIndex | 1.3.6.1.4.1.19046.11.1.3.1.3.1.1.1 | INTEGER (1..10000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10000) · read-only · mandatory Index for remote alert entry. | |||||||||||||||||||||
| CremoteAlertIdEntryStatus | 1.3.6.1.4.1.19046.11.1.3.1.3.1.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory If enabled alerts will be sent to this alert recipient else alerts will not be sent.
| |||||||||||||||||||||
| CremoteAlertIdEntryName | 1.3.6.1.4.1.19046.11.1.3.1.3.1.1.3 | OCTET STRING (SIZE (0..50)) | RO | mandatory | |||||||||||||||||
column · OCTET STRING (SIZE (0..50)) · read-only · mandatory A null terminated string that contains a text description of this entry. | |||||||||||||||||||||
| CremoteAlertIdEmailAddr | 1.3.6.1.4.1.19046.11.1.3.1.3.1.1.4 | OCTET STRING (SIZE (0..320)) | RO | mandatory | |||||||||||||||||
column · OCTET STRING (SIZE (0..320)) · read-only · mandatory A null terminated string that contains a E-Mail Address. For example '[email protected]'. Used only for a E-mail over Lan. | |||||||||||||||||||||
| CremoteAlertIdEntryCriticalAlert | 1.3.6.1.4.1.19046.11.1.3.1.3.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory If Enabled,criticalAlerts will be sent to this remote alert receipient,else critical alerts will not be sent.
| |||||||||||||||||||||
| CremoteAlertIdEntryWarningAlert | 1.3.6.1.4.1.19046.11.1.3.1.3.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory If Enabled,warningAlerts will be sent to this remote alert receipient,else warningAlerts will not be sent.
| |||||||||||||||||||||
| CremoteAlertIdEntrySystemAlert | 1.3.6.1.4.1.19046.11.1.3.1.3.1.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory If Enabled,systemAlerts will be sent to this remote alert receipient,else systemAlerts will not be sent.
| |||||||||||||||||||||
| CremoteAlertIdEntryAuditAlert | 1.3.6.1.4.1.19046.11.1.3.1.3.1.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory If Enabled,systemAlerts will be sent to this remote alert receipient,else systemAlerts will not be sent.
| |||||||||||||||||||||
| CremoteAlertIdEntryAttachmentsToEmailAlerts | 1.3.6.1.4.1.19046.11.1.3.1.3.1.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates if the event log should be attached to a email alert.
| |||||||||||||||||||||
| CremoteAlertIdEntrySyslogPortAssignment | 1.3.6.1.4.1.19046.11.1.3.1.3.1.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Syslog port number. | |||||||||||||||||||||
| CremoteAlertIdEntrySyslogHostname | 1.3.6.1.4.1.19046.11.1.3.1.3.1.1.11 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · OCTET STRING (SIZE (0..63)) · read-only · mandatory Syslog hostname or IP address. | |||||||||||||||||||||
| CremoteAlertIdEntryType | 1.3.6.1.4.1.19046.11.1.3.1.3.1.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Alert recipient type.
| |||||||||||||||||||||
| TremoteAlertFiltersTable | 1.3.6.1.4.1.19046.11.1.3.1.3.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Alert Filters. The entries (rows) in this table correspond 1-1 with the entries in the remoteAlertIdsTable. They are correlated by index. | |||||||||||||||||||||
| RremoteAlertFiltersEntry | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1 | NA | mandatory | ||||||||||||||||||
| CrafIndex | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.1 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Index for User Authority Level entry. | |||||||||||||||||||||
| CrafSpTrapTempC | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Critical Alert: Temperature threshold exceeded.
| |||||||||||||||||||||
| CrafSpTrapVoltC | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Critical Alert: Voltage threshold exceeded.
| |||||||||||||||||||||
| CrafSpTrapPowerC | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Critical Alert: Power failure.
| |||||||||||||||||||||
| CrafSpTrapHdC | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Critical Alert: Hard disk drive failure.
| |||||||||||||||||||||
| CrafSpTrapFanC | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Critical Alert: Single Fan failure.
| |||||||||||||||||||||
| CrafSpTrapIhcC | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Critical Alert: Incompatible hardware configuration.
| |||||||||||||||||||||
| CrafSpTrapCPUC | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Critical Alert: CPU Error.
| |||||||||||||||||||||
| CrafSpTrapMemoryC | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Critical Alert: Memory Error.
| |||||||||||||||||||||
| CrafSpTrapRdpsC | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Critical Alert: Redundant Power Supply failure.
| |||||||||||||||||||||
| CrafSpTrapHardwareC | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Critical Alert: Other Failure - refer to Message ID for specific condition.
| |||||||||||||||||||||
| CrafSpTrapRdpsN | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Non-Critical Alert: Redundant Power Supply failure.
| |||||||||||||||||||||
| CrafSpTrapTempN | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Non-Critical Alert: Temperature threshold exceeded.
| |||||||||||||||||||||
| CrafSpTrapVoltN | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.14 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Non-Critical Alert: Voltage threshold exceeded.
| |||||||||||||||||||||
| CrafSpTrapPowerN | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.15 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Non-Critical Alert: Power.
| |||||||||||||||||||||
| CrafSpTrapFanN | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.16 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Non-Critical Alert: Fan Error.
| |||||||||||||||||||||
| CrafSpTrapCPUN | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.17 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Non-Critical Alert: Memory Error.
| |||||||||||||||||||||
| CrafSpTrapMemoryN | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.18 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Non-Critical Alert: Memory Error.
| |||||||||||||||||||||
| CrafSpTrapHardwareN | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.19 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Non-Critical Alert: Warning - refer to Message ID for specific condition.
| |||||||||||||||||||||
| CrafSpTrapRLogin | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.20 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Sev-Off Alert: Event Remote Login.
| |||||||||||||||||||||
| CrafSpTrapOsToS | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.21 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System Alert: OS Timeout value exceeded.
| |||||||||||||||||||||
| CrafSpTrapAppS | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.22 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System Alert: Application Alert. Refer to Message ID for specific condition.
| |||||||||||||||||||||
| CrafSpTrapPowerS | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.23 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System Alert: Power On or Off.
| |||||||||||||||||||||
| CrafSpTrapBootS | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.24 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System Alert: System Boot Failure.
| |||||||||||||||||||||
| CrafSpTrapLdrToS | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.25 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System Alert: OS Loader Timeout.
| |||||||||||||||||||||
| CrafSpTrapPFAS | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.26 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System Alert: Predictive Failure Analysis(PFA) information.
| |||||||||||||||||||||
| CrafSpTrapSysLogS | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.27 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System Alert: System Log 75% full.
| |||||||||||||||||||||
| CrafSpTrapNwChangeS | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.28 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System Alert: Network change notification.
| |||||||||||||||||||||
| CrafSpTrapAllAuditS | 1.3.6.1.4.1.19046.11.1.3.1.3.2.1.29 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory System Alert: All Audit Events notification.
| |||||||||||||||||||||
| NremoteAccessIds | 1.3.6.1.4.1.19046.11.1.3.1.4 | ||||||||||||||||||||
| TremoteAccessIdsTable | 1.3.6.1.4.1.19046.11.1.3.1.4.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of remote access profiles. This table lets you to configure all login profiles. You can define up to 12 unique profiles. Note: By default, the remote supervisor adapter comes configured with one login profile that allows remote access using a login ID of 'USERID' and a password of 'PASSW0RD' (the 0 is a zero). To avoid a potential security exposure, we strongly recommend that you change this default Login Profile to values of your choice. | |||||||||||||||||||||
| RremoteAccessIdsEntry | 1.3.6.1.4.1.19046.11.1.3.1.4.1.1 | NA | mandatory | ||||||||||||||||||
| CremoteAccessIdEntryIndex | 1.3.6.1.4.1.19046.11.1.3.1.4.1.1.1 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Index for Remote access entry. | |||||||||||||||||||||
| CremoteAccessIdEntryUserId | 1.3.6.1.4.1.19046.11.1.3.1.4.1.1.2 | OCTET STRING (SIZE (0..16)) | RO | mandatory | |||||||||||||||||
column · OCTET STRING (SIZE (0..16)) · read-only · mandatory Remote access entry null terminated string that contains the user-id. This can only be modified from blank to non-blank, then back to blank. | |||||||||||||||||||||
| CremoteAccessIdEntryUserPwdLeftDays | 1.3.6.1.4.1.19046.11.1.3.1.4.1.1.3 | INTEGER (0..365) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..365) · read-only · mandatory left days before password expired for selected user | |||||||||||||||||||||
| TremoteAccessUserAuthorityLevelTable | 1.3.6.1.4.1.19046.11.1.3.1.4.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of user authority level profiles. | |||||||||||||||||||||
| RremoteAccessUserAuthorityLevelEntry | 1.3.6.1.4.1.19046.11.1.3.1.4.2.1 | NA | mandatory | ||||||||||||||||||
| CualIndex | 1.3.6.1.4.1.19046.11.1.3.1.4.2.1.1 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Index for User Authority Level entry. | |||||||||||||||||||||
| CualId | 1.3.6.1.4.1.19046.11.1.3.1.4.2.1.2 | OCTET STRING (SIZE (0..16)) | RO | mandatory | |||||||||||||||||
column · OCTET STRING (SIZE (0..16)) · read-only · mandatory User ID | |||||||||||||||||||||
| CualSupervisor | 1.3.6.1.4.1.19046.11.1.3.1.4.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory User has no restrictions.
| |||||||||||||||||||||
| CualReadOnly | 1.3.6.1.4.1.19046.11.1.3.1.4.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory User has only read-only access, and cannot perform any save, modify, clear, or state affecting operations (eg. restart XCC, restore defaults, upgrade the firmware, etc.).
| |||||||||||||||||||||
| CualAccountManagement | 1.3.6.1.4.1.19046.11.1.3.1.4.2.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory It is custom user authority level. User can add/modify/delete users and change the global login settings in the Login Profiles panel. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.
| |||||||||||||||||||||
| CualConsoleAccess | 1.3.6.1.4.1.19046.11.1.3.1.4.2.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory It is custom user authority level. User can access the remote console. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.
| |||||||||||||||||||||
| CualConsoleAndVirtualMediaAccess | 1.3.6.1.4.1.19046.11.1.3.1.4.2.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory It is custom user authority level. User can access both the remote console and the virtual media feature. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.
| |||||||||||||||||||||
| CualServerPowerAccess | 1.3.6.1.4.1.19046.11.1.3.1.4.2.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory It is custom user authority level. User can access the power on and restart functions for the remote server. These functions are available via the Power/Restart panel. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.
| |||||||||||||||||||||
| CualAllowClearLog | 1.3.6.1.4.1.19046.11.1.3.1.4.2.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory It is custom user authority level. User can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the logs. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.
| |||||||||||||||||||||
| CualAdapterBasicConfig | 1.3.6.1.4.1.19046.11.1.3.1.4.2.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory It is custom user authority level. User can modify configuration parameters in the System Settings and Alerts panels. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.
| |||||||||||||||||||||
| CualAdapterNetworkAndSecurityConfig | 1.3.6.1.4.1.19046.11.1.3.1.4.2.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory It is custom user authority level. User can modify configuration parameters in the Security, Network Protocols, Network Interface, Port Assignments, and Serial Port panels. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.
| |||||||||||||||||||||
| CualAdapterAdvancedConfig | 1.3.6.1.4.1.19046.11.1.3.1.4.2.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory It is custom user authority level. User has no restrictions when configuring the adapter. In addition, the user is said to have administrative access to the XCC, meaning that the user can also perform the following advanced functions: firmware upgrades, PXE network boot, restore adapter factory defaults, modify and restore adapter configuration from a configuration file, and restart/reset the adapter. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.
| |||||||||||||||||||||
| NgroupProfiles | 1.3.6.1.4.1.19046.11.1.3.1.5 | ||||||||||||||||||||
| TgroupIdsTable | 1.3.6.1.4.1.19046.11.1.3.1.5.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Group profiles. This table lets you to configure all group profiles. You can define up to 16 unique profiles. | |||||||||||||||||||||
| RgroupIdsEntry | 1.3.6.1.4.1.19046.11.1.3.1.5.1.1 | NA | mandatory | ||||||||||||||||||
| CgroupIndex | 1.3.6.1.4.1.19046.11.1.3.1.5.1.1.1 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Index for Group IDs entry. | |||||||||||||||||||||
| CgroupId | 1.3.6.1.4.1.19046.11.1.3.1.5.1.1.2 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · OCTET STRING (SIZE (0..63)) · read-only · mandatory Group ID. It is a null terminated string that contains the group-id. It must not be a duplicate of any previously configured ones. | |||||||||||||||||||||
| CgroupRole | 1.3.6.1.4.1.19046.11.1.3.1.5.1.1.3 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory Group Role. It indicates if the group has supervisor, operator, or custom access. | |||||||||||||||||||||
| TgroupRBSroleTable | 1.3.6.1.4.1.19046.11.1.3.1.5.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Group Role profiles. | |||||||||||||||||||||
| RgroupRBSroleEntry | 1.3.6.1.4.1.19046.11.1.3.1.5.2.1 | NA | mandatory | ||||||||||||||||||
| CgroupRBSroleIndex | 1.3.6.1.4.1.19046.11.1.3.1.5.2.1.1 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Index for Group Role entry. | |||||||||||||||||||||
| CgroupRBSroleId | 1.3.6.1.4.1.19046.11.1.3.1.5.2.1.2 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · OCTET STRING (SIZE (0..63)) · read-only · mandatory Group ID | |||||||||||||||||||||
| CgroupRBSSupervisor | 1.3.6.1.4.1.19046.11.1.3.1.5.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Group has no restrictions.
| |||||||||||||||||||||
| CgroupRBSOperator | 1.3.6.1.4.1.19046.11.1.3.1.5.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Group has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart XCC, restore defaults, upgrade the firmware, etc.).
| |||||||||||||||||||||
| CgroupRBSNetworkSecurity | 1.3.6.1.4.1.19046.11.1.3.1.5.2.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Group can modify the configuration in the Security, Network Protocols, Network Interface, Port Assignments, and Serial Port panels.
| |||||||||||||||||||||
| CgroupRBSUserAccountManagement | 1.3.6.1.4.1.19046.11.1.3.1.5.2.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Group can add/modify/delete users and change the Global Login Settings in the Login Profiles panel.
| |||||||||||||||||||||
| CgroupRBSRemoteConsoleAccess | 1.3.6.1.4.1.19046.11.1.3.1.5.2.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Group can access the remote server console.
| |||||||||||||||||||||
| CgroupRBSRemoteConsoleRemoteDiskAccess | 1.3.6.1.4.1.19046.11.1.3.1.5.2.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Group can access the remote server console and the remote disk functions for the remote server.
| |||||||||||||||||||||
| CgroupRBSServerPowerRestartAccess | 1.3.6.1.4.1.19046.11.1.3.1.5.2.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Group can access the power on, restart and server timeout functions for the remote server.
| |||||||||||||||||||||
| CgroupRBSBasicAdapterConfiguration | 1.3.6.1.4.1.19046.11.1.3.1.5.2.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Group can modify configuration parameters in the System Settings (excluding Contact, Location and Server Timeouts) and Alerts panels.
| |||||||||||||||||||||
| CgroupRBSClearEventLog | 1.3.6.1.4.1.19046.11.1.3.1.5.2.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Group can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the logs.
| |||||||||||||||||||||
| CgroupRBSAdvancedAdapterConfiguration | 1.3.6.1.4.1.19046.11.1.3.1.5.2.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Group has no restrictions when configuring the adapter. In addition the user is said to have administrative access to the XCC, meaning that the user can also perform the following advanced functions: firmware upgrades, PXE network boot, restore adapter factory defaults, modify and restore adapter configuration from a configuration file, and restart/reset the adapter. This excludes Server Power/Restart Control and timeout functions.
| |||||||||||||||||||||
| NsshClientAuth | 1.3.6.1.4.1.19046.11.1.3.1.6 | ||||||||||||||||||||
| TsshClientAuthPubKeyTable | 1.3.6.1.4.1.19046.11.1.3.1.6.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table that contains client authentication public key information. | |||||||||||||||||||||
| RsshClientAuthPubKeyEntry | 1.3.6.1.4.1.19046.11.1.3.1.6.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory A information list about a particular SSH public key used for client authentication. The primary table index is the same value as the associated remoteAccessIdEntryIndex. The secondary table index allows selection of the Nth public key for that remoteAccessIdEntryIndex. | |||||||||||||||||||||
| CsshClientAuthRemoteAccessIdIndex | 1.3.6.1.4.1.19046.11.1.3.1.6.1.1.1 | INTEGER (1..1000) | NA | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · not-accessible · mandatory The primary table index is the same value as the associated remoteAccessIdEntryIndex used as an index into the remoteAccessIdsTable. | |||||||||||||||||||||
| CsshClientAuthPubKeyIndex | 1.3.6.1.4.1.19046.11.1.3.1.6.1.1.2 | INTEGER (1..1000) | NA | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · not-accessible · mandatory The secondary table index used to select one of the client authentication public keys for a particular remote access Id. The index is an integer value from 1 to N where N is the number of keys associated with a particular remote access Id. An addition always causes the value of N to increase by one, effectively adding an entry after the existing keys for that remote access Id. The underlying SSH server implementation searches the keys in order from 1 to N when attempting public key authentication. NOTE:A maximum of 4 public keys can be installed for one remote access Id. | |||||||||||||||||||||
| CsshClientAuthPubKeyType | 1.3.6.1.4.1.19046.11.1.3.1.6.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The type of the SSH public key represented by this entry.
| |||||||||||||||||||||
| CsshClientAuthPubKeySize | 1.3.6.1.4.1.19046.11.1.3.1.6.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The size of the SSH public key represented by this entry.
| |||||||||||||||||||||
| CsshClientAuthPubKeyFingerprint | 1.3.6.1.4.1.19046.11.1.3.1.6.1.1.5 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory The RSA fingerprint of the SSH public key represented by this entry. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the managed entity. This is the fingerprint of the operational host key pair. If the key pair represented by this entry is not operational then sixteen null octets must be returned. | |||||||||||||||||||||
| CsshClientAuthPubKeyAcceptFrom | 1.3.6.1.4.1.19046.11.1.3.1.6.1.1.6 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory This is a filter that describes the set of SSH client
IP addresses and host names that can establish
SSH connections to the AMM authenticated by the public key
represented by this entry of the table. The filter is a
comma-separated list of IP addresses and/or hostnames.
A question mark may be used to match any single character.
An asterisk may be used to match multiple characters.
An exclamation point may preceed an IP address or hostname
to deny acccess from that IP address or hostname.
The format of the Accept From specification is:
from=PATTERN-LIST
PATTERN-LIST is the filter, which must be enclosed in
double quotation marks. | |||||||||||||||||||||
| SsshClientAuthPubKeyUnused | 1.3.6.1.4.1.19046.11.1.3.1.6.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of available storage locations that may be used to install additional Client Authentication Public Keys. This number decreases by one when a new key is added to the configuration. | |||||||||||||||||||||
| NspClock | 1.3.6.1.4.1.19046.11.1.3.2 | ||||||||||||||||||||
| SspClockDateAndTimeSetting | 1.3.6.1.4.1.19046.11.1.3.2.1 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory Display XCC clock date and time setting, The format of the value is month/day/year, hour:minutes:seconds. | |||||||||||||||||||||
| SspClockTimezoneSetting | 1.3.6.1.4.1.19046.11.1.3.2.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory Display XCC clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST)
settings.
The following table lists GMT offsets and associated DST
information. DST is not observed in time zones where
the 'Observe DST' value does not contain 'yes' in the table.
Also, note that in some cases additional information
is required to determine the clock adjustment when DST is
observed.
Examples
-If the GMT offset is +3:30, the value is:'+3:30,no'
-For Eastern Standard Time and observing DST, the value is:'-5:00,yes'
-For Turkey and observing DST, the value is:'+2:00,yes,3'
GMT Observe Additional
Offset DST? DST value
______ _______ __________
GMT+0 yes | no
GMT+1 yes | no
GMT+2 yes | no When 'Observe DST?' value is 'yes':
'1' Europe/Eastern Europe (ee)
'3' Turkey (tky)
'4' Asia/Beirut (bei)
'5' Asia/Amman (amm)
'6' Asia/Jerusalem (jem)
GMT+3 yes | no
GMT+3:30 yes | no
GMT+4 no
GMT+4:30 no
GMT+5 no
GMT+5:30 no
GMT+5:45 no
GMT+6 no
GMT+6:30 no
GMT+7 no
GMT+8 no
GMT+9 no
GMT+9:30 yes | no
GMT+10 yes | no
GMT+11 no
GMT+12 yes | no
GMT+13 no
GMT-12 no
GMT-11 yes | no
GMT-10 no
GMT-9 yes | no
GMT-8 yes | no
GMT-7 yes | no When 'Observe DST?' value is 'yes':
'7' US/Mountain (mtn)
'8' America/Mazatlan (maz)
GMT-6 yes | no When 'Observe DST?' value is 'yes':
'9' America/Mexico City (mex)
'10' Canada/Central (cna)
GMT-5 yes | no When 'Observe DST?' value is 'yes':
'11' Cuba (cub)
GMT-4:30 no
GMT-4 yes | no When 'Observe DST?' value is 'yes':
'13' America/Asuncion (asu)
'14' America/Cuiaba (cui)
'15' America/Santiago (san)
'16' Canada/Atlantic (cat)
GMT-3:30 yes | no
GMT-3 yes | no When 'Observe DST?' value is 'yes':
'17' America/Gothab (gtb)
'19' Brazil/East (bre)
GMT-2 no
GMT-1 yes | no | |||||||||||||||||||||
| NspIdentification | 1.3.6.1.4.1.19046.11.1.3.3 | ||||||||||||||||||||
| SspTxtId | 1.3.6.1.4.1.19046.11.1.3.3.1 | OCTET STRING (SIZE (0..256)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..256)) · read-only · mandatory XCC text ID. | |||||||||||||||||||||
| SspRoomID | 1.3.6.1.4.1.19046.11.1.3.3.2 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Room where the system is located. | |||||||||||||||||||||
| SspRackID | 1.3.6.1.4.1.19046.11.1.3.3.3 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory ID for Rack that contains this system. | |||||||||||||||||||||
| SspRackUnitPosition | 1.3.6.1.4.1.19046.11.1.3.3.4 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Position within the rack for this system. | |||||||||||||||||||||
| SspRackUnitHeight | 1.3.6.1.4.1.19046.11.1.3.3.5 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Number of rack units occupied by this system. | |||||||||||||||||||||
| SspRackBladeBay | 1.3.6.1.4.1.19046.11.1.3.3.6 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Bay number for system contained in a blade chassis. | |||||||||||||||||||||
| SspFullPostalAddress | 1.3.6.1.4.1.19046.11.1.3.3.7 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory A NULL terminated 300 byte string that contains the full postal address for this system. | |||||||||||||||||||||
| NnetworkConfiguration | 1.3.6.1.4.1.19046.11.1.3.4 | ||||||||||||||||||||
| NnetworkInterfaces | 1.3.6.1.4.1.19046.11.1.3.4.1 | ||||||||||||||||||||
| NethernetInterface | 1.3.6.1.4.1.19046.11.1.3.4.1.1 | ||||||||||||||||||||
| SethernetInterfaceType | 1.3.6.1.4.1.19046.11.1.3.4.1.1.1 | OCTET STRING (SIZE (0..16)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..16)) · read-only · mandatory The type of interface. Indicates 'Ethernet-1'. | |||||||||||||||||||||
| SethernetInterfaceEnabled | 1.3.6.1.4.1.19046.11.1.3.4.1.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Disable or enable the interface.
| |||||||||||||||||||||
| SethernetInterfaceHostName | 1.3.6.1.4.1.19046.11.1.3.4.1.1.3 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory Contains the 64 byte null terminated DNS host name for this interface. | |||||||||||||||||||||
| SethernetInterfaceIPAddress | 1.3.6.1.4.1.19046.11.1.3.4.1.1.4 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the IP address for the ethernet interface. | |||||||||||||||||||||
| SethernetInterfaceAutoNegotiate | 1.3.6.1.4.1.19046.11.1.3.4.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory If this is enabled, then we should ignore Speed/Duplex.
| |||||||||||||||||||||
| SethernetInterfaceDataRate | 1.3.6.1.4.1.19046.11.1.3.4.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Specifies the data transfer rate to be used over the ethernet interface 10Mb/100Mb/Auto. Note that the value of this variable is ignored if ethernetInterfaceAutoNegotiate is set to enabled(0).
| |||||||||||||||||||||
| SethernetInterfaceDuplexSetting | 1.3.6.1.4.1.19046.11.1.3.4.1.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Specifies the duplex settings for the data transfer rate to be used over the ethernet interface Half/Full/Auto.
| |||||||||||||||||||||
| SethernetInterfaceLAA | 1.3.6.1.4.1.19046.11.1.3.4.1.1.8 | OCTET STRING (SIZE (17)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (17)) · read-only · mandatory Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This XCC subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. | |||||||||||||||||||||
| SethernetInterfaceDhcpEnabled | 1.3.6.1.4.1.19046.11.1.3.4.1.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Disable or enable DHCP on this interface.
| |||||||||||||||||||||
| SethernetInterfaceGatewayIPAddress | 1.3.6.1.4.1.19046.11.1.3.4.1.1.10 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the IP address of the gateway/router for the ethernet interface. | |||||||||||||||||||||
| SethernetInterfaceBIA | 1.3.6.1.4.1.19046.11.1.3.4.1.1.11 | OCTET STRING (SIZE (6)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (6)) · read-only · mandatory Specifies the burned-in MAC (BIA) address. | |||||||||||||||||||||
| SethernetInterfaceMTU | 1.3.6.1.4.1.19046.11.1.3.4.1.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Contains the Maximum Transmission Unit(MTU) for the ethernet interface | |||||||||||||||||||||
| SethernetInterfaceSubnetMask | 1.3.6.1.4.1.19046.11.1.3.4.1.1.13 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the Subnet Mask for the ethernet interface | |||||||||||||||||||||
| NdhcpEthernetInterface | 1.3.6.1.4.1.19046.11.1.3.4.1.1.14 | ||||||||||||||||||||
| SdhcpHostName | 1.3.6.1.4.1.19046.11.1.3.4.1.1.14.1 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. | |||||||||||||||||||||
| SdhcpIPAddress | 1.3.6.1.4.1.19046.11.1.3.4.1.1.14.2 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the IP address for the ehternet interface, assigned by the DHCP server. | |||||||||||||||||||||
| SdhcpGatewayIPAddress | 1.3.6.1.4.1.19046.11.1.3.4.1.1.14.3 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. | |||||||||||||||||||||
| SdhcpSubnetMask | 1.3.6.1.4.1.19046.11.1.3.4.1.1.14.4 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server. | |||||||||||||||||||||
| SdhcpDomainName | 1.3.6.1.4.1.19046.11.1.3.4.1.1.14.5 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. | |||||||||||||||||||||
| SdhcpPrimaryDNSServer | 1.3.6.1.4.1.19046.11.1.3.4.1.1.14.6 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the Primary DNS server, assigned by the DHCP server. | |||||||||||||||||||||
| SdhcpSecondaryDNSServer | 1.3.6.1.4.1.19046.11.1.3.4.1.1.14.7 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the Secondary DNS server, assigned by the DHCP server. | |||||||||||||||||||||
| SdhcpTertiaryDNSServer | 1.3.6.1.4.1.19046.11.1.3.4.1.1.14.8 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the tertiary DNS server, assigned by the DHCP server. | |||||||||||||||||||||
| SethernetInterfaceVlan | 1.3.6.1.4.1.19046.11.1.3.4.1.1.15 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory If this is enabled, assign VLAN ID needs to be assigned. NOTE: This is not supported on blades.
| |||||||||||||||||||||
| SethernetInterfaceVlanID | 1.3.6.1.4.1.19046.11.1.3.4.1.1.16 | INTEGER (1..4094) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..4094) · read-only · mandatory Contains the VLAN ID for the ethernet interface. NOTE: This is not supported in blades. | |||||||||||||||||||||
| NethernetInterfaceIPv6 | 1.3.6.1.4.1.19046.11.1.3.4.1.4 | ||||||||||||||||||||
| SethernetInterfaceIPv6Enabled | 1.3.6.1.4.1.19046.11.1.3.4.1.4.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The current IPv6 enabled or disabled state of this XCC. NOTE: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this XCC, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces.
| |||||||||||||||||||||
| NethernetInterfaceIPv6Config | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5 | ||||||||||||||||||||
| NethernetInterfaceIPv6LocalAddress | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.1 | ||||||||||||||||||||
| SethernetInterfaceIPv6LinkLocalAddress | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.1.1 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory The IPv6 link local IP address for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | |||||||||||||||||||||
| NethernetInterfaceIPv6StaticIPConfig | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2 | ||||||||||||||||||||
| SethernetInterfaceIPv6StaticIPConfigEnabled | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The IPv6 static IP address enabled or disabled state for the ethernet interface.
| |||||||||||||||||||||
| SethernetInterfaceIPv6StaticIPAddress | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2.2 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory The IPv6 static IP address for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | |||||||||||||||||||||
| SethernetInterfaceIPv6StaticIPAddressPrefixLen | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2.3 | INTEGER (1..128) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..128) · read-only · mandatory The IPv6 static IP address prefix length for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value 0. | |||||||||||||||||||||
| SethernetInterfaceIPv6StaticIPDefaultRoute | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2.4 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory The IPv6 static IP address default route for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | |||||||||||||||||||||
| NethernetInterfaceIPv6AutoIPConfig | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3 | ||||||||||||||||||||
| NethernetInterfaceDHCPv6Config | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2 | ||||||||||||||||||||
| SethernetInterfaceDHCPv6Enabled | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The DHCPv6 enabled or disabled state for the ethernet interface.
| |||||||||||||||||||||
| SethernetInterfaceDHCPv6IPAddress | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.2 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory The IPv6 address for the ethernet interface, assigned by DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | |||||||||||||||||||||
| SethernetInterfaceDHCPv6DomainName | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.4 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory The 64 byte Domain Name for the ethernet interface, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '(Not available)'. | |||||||||||||||||||||
| SethernetInterfaceDHCPv6PrimaryDNSServer | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.5 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory The primary DNS server, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | |||||||||||||||||||||
| SethernetInterfaceDHCPv6SecondaryDNSServer | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.6 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory The secondary DNS server, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | |||||||||||||||||||||
| SethernetInterfaceDHCPv6TertiaryDNSServer | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.7 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory The tertiary DNS server, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | |||||||||||||||||||||
| SethernetInterfaceDHCPv6Server | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.8 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory The DHCPv6 server IPv6 address used to acquire the DHCP settings. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | |||||||||||||||||||||
| NethernetInterfaceIPv6StatelessAutoConfig | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3 | ||||||||||||||||||||
| SethernetInterfaceIPv6StatelessAutoConfigEnabled | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface.
| |||||||||||||||||||||
| TethernetInterfaceStatelessAutoConfigAddressesTable | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of stateless Auto-Config addresses entries | |||||||||||||||||||||
| RethernetInterfaceStatelessAutoConfigAddressesEntry | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Stateless Auto-Config address entries | |||||||||||||||||||||
| CethernetInterfaceStatelessAutoConfigAddressesIndex | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2.1.1 | INTEGER (1..1000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory Index for stateless Auto-Config addresses. NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or ethernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. | |||||||||||||||||||||
| CethernetInterfaceStatelessAutoConfigAddresses | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2.1.2 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
column · InetAddressIPv6 · read-only · mandatory The stateless Auto-Configuration IPv6 address. NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or ethernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. | |||||||||||||||||||||
| CethernetInterfaceStatelessAutoConfigAddressesPrefixLen | 1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2.1.3 | INTEGER (1..128) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..128) · read-only · mandatory The stateless Auto-Configration address prefix length. NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or ethernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. | |||||||||||||||||||||
| NvlansSM | 1.3.6.1.4.1.19046.11.1.3.4.1.5 | ||||||||||||||||||||
| NvlansSMvlan1config | 1.3.6.1.4.1.19046.11.1.3.4.1.5.1 | ||||||||||||||||||||
| SvlansSMvlan1Name | 1.3.6.1.4.1.19046.11.1.3.4.1.5.1.1 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The name of VLAN1, 1-64 characters. | |||||||||||||||||||||
| SvlansSMvlan1vlanId | 1.3.6.1.4.1.19046.11.1.3.4.1.5.1.2 | INTEGER (1..4094) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..4094) · read-only · mandatory The VLAN ID for VLAN1. | |||||||||||||||||||||
| SvlansSMvlan1State | 1.3.6.1.4.1.19046.11.1.3.4.1.5.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The state of VLAN1
| |||||||||||||||||||||
| SvlansSMvlan1RemoteControl | 1.3.6.1.4.1.19046.11.1.3.4.1.5.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The state of the Remote Control feature for VLAN1. Note that Remote Control can only be enabled on one VLAN.
| |||||||||||||||||||||
| SvlansSMvlan1SSerialOverLan | 1.3.6.1.4.1.19046.11.1.3.4.1.5.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The state of the Serail Over LAN feature for VLAN1. Note that Serial Over LAN can only be enabled on one VLAN.
| |||||||||||||||||||||
| NvlansSMvlan2config | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2 | ||||||||||||||||||||
| SvlansSMvlan2Name | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.1 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The name of VLAN1, 1-64 characters. | |||||||||||||||||||||
| SvlansSMvlan2vlanId | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.2 | INTEGER (1..4094) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..4094) · read-only · mandatory The VLAN ID for VLAN2. | |||||||||||||||||||||
| SvlansSMvlan2State | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The state of VLAN2
| |||||||||||||||||||||
| SvlansSMvlan2RemoteControl | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The state of the Remote Control feature for VLAN2. Note that Remote Control can only be enabled on one VLAN.
| |||||||||||||||||||||
| SvlansSMvlan2SerialOverLan | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The state of the Serail Over LAN feature for VLAN2. Note that Serial Over LAN can only be enabled on one VLAN.
| |||||||||||||||||||||
| NvlansSMvlan2ipv4Config | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.6 | ||||||||||||||||||||
| SvlansSMvlan2IPv4Address | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.6.1 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the IPv4 address for the VLAN2 interface. | |||||||||||||||||||||
| SvlansSMvlan2IPv4Gateway | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.6.2 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the Gateway IPv4 address for the VLAN2 interface. | |||||||||||||||||||||
| SvlansSMvlan2IPv4SubnetMask | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.6.3 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the Subnet Mask for the IPv4 address for the VLAN2 interface. | |||||||||||||||||||||
| NvlansSMvlan2ipv6Config | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.7 | ||||||||||||||||||||
| SvlansSMvlan2IPv6Address | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.7.1 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory Contains the IPv6 address for the VLAN2 interface. | |||||||||||||||||||||
| SvlansSMvlan2IPv6Gateway | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.7.2 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory Contains the Gateway IPv6 address for the VLAN2 interface. | |||||||||||||||||||||
| SvlansSMvlan2IPv6PrefixLength | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.7.3 | INTEGER (1..128) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..128) · read-only · mandatory Contains the Prefix Length for the IPv6 address for the VLAN2 interface. | |||||||||||||||||||||
| NvlansSMvlan2ipv4StatusRoutes | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8 | ||||||||||||||||||||
| SvlansSMvlan2IPv4StaticRouteIP1 | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.1 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the IPv4 address for the first IPv4 static route. | |||||||||||||||||||||
| SvlansSMvlan2IPv4StaticRouteSM1 | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.2 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the Subnet Mask for the first IPv4 static route. | |||||||||||||||||||||
| SvlansSMvlan2IPv4StaticRouteIP2 | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.3 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the IPv4 address for the second IPv4 static route. | |||||||||||||||||||||
| SvlansSMvlan2IPv4StaticRouteSM2 | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.4 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the Subnet Mask for the second IPv4 static route. | |||||||||||||||||||||
| SvlansSMvlan2IPv4StaticRouteIP3 | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.5 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the IPv4 address for the third IPv4 static route. | |||||||||||||||||||||
| SvlansSMvlan2IPv4StaticRouteSM3 | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.6 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the Subnet Mask for the third IPv4 static route. | |||||||||||||||||||||
| NvlansSMvlan2ipv6StatusRoutes | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9 | ||||||||||||||||||||
| SvlansSMvlan2IPv6StaticRouteIP1 | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.1 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory Contains the IPv6 address for the first IPv6 static route. | |||||||||||||||||||||
| SvlansSMvlan2IPv6StaticRoutePL1 | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.2 | INTEGER (1..128) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..128) · read-only · mandatory Contains the Prefix Length for the first IPv6 static route. | |||||||||||||||||||||
| SvlansSMvlan2IPv6StaticRouteIP2 | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.3 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory Contains the IPv6 address for the second IPv6 static route. | |||||||||||||||||||||
| SvlansSMvlan2IPv6StaticRoutePL2 | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.4 | INTEGER (1..128) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..128) · read-only · mandatory Contains the Prefix Length for the second IPv6 static route. | |||||||||||||||||||||
| SvlansSMvlan2IPv6StaticRouteIP3 | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.5 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory Contains the IPv6 address for the third IPv6 static route. | |||||||||||||||||||||
| SvlansSMvlan2IPv6StaticRoutePL3 | 1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.6 | INTEGER (1..128) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..128) · read-only · mandatory Contains the Prefix Length for the third IPv6 static route. | |||||||||||||||||||||
| NvlansSMvlanControl | 1.3.6.1.4.1.19046.11.1.3.4.1.5.3 | ||||||||||||||||||||
| SvlansSMvlanConfigRevertTimout | 1.3.6.1.4.1.19046.11.1.3.4.1.5.3.1 | INTEGER (1..60) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..60) · read-only · mandatory Contains the VLAN Config Revert Timeout value. | |||||||||||||||||||||
| SddnsStatus | 1.3.6.1.4.1.19046.11.1.3.4.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Dynamic DNS provides the capability for a networked device to notify a domain name server to change, in real time, the active DNS configuration of its configured hostnames, addresses or other information stored in DNS. With Dynamic DNS, host computers gain the capability to notify their respective DNS server of the IP address they have received from a DHCP server or through self-configuration.
| |||||||||||||||||||||
| ShostName | 1.3.6.1.4.1.19046.11.1.3.4.1.11 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory Contains the DNS host name for this system. This object provides the exact same function as ethernetInterfaceHostName | |||||||||||||||||||||
| SddnsDomainToUse | 1.3.6.1.4.1.19046.11.1.3.4.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The domain name to be used with Dynamic DNS.
| |||||||||||||||||||||
| SdomainName | 1.3.6.1.4.1.19046.11.1.3.4.1.13 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The user assigned DNS domain name. | |||||||||||||||||||||
| NlanOverUSBInterface | 1.3.6.1.4.1.19046.11.1.3.4.1.14 | ||||||||||||||||||||
| SxccUSBIPAddress | 1.3.6.1.4.1.19046.11.1.3.4.1.14.1 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the IP address for the LAN over USB of XCC. | |||||||||||||||||||||
| SxccUSBSubnetMask | 1.3.6.1.4.1.19046.11.1.3.4.1.14.2 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the Subnet Mask for the LAN over USB of XCC. | |||||||||||||||||||||
| SosUSBIPAddress | 1.3.6.1.4.1.19046.11.1.3.4.1.14.3 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the IP address for the LAN over USB of OS. | |||||||||||||||||||||
| NtcpProtocols | 1.3.6.1.4.1.19046.11.1.3.4.2 | ||||||||||||||||||||
| NsnmpAgentConfig | 1.3.6.1.4.1.19046.11.1.3.4.2.1 | ||||||||||||||||||||
| SsnmpSystemName | 1.3.6.1.4.1.19046.11.1.3.4.2.1.1 | OCTET STRING (SIZE (0..48)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..48)) · read-only · mandatory A NULL terminated 48 byte string that contains the SNMP agent name. | |||||||||||||||||||||
| SsnmpSystemContact | 1.3.6.1.4.1.19046.11.1.3.4.2.1.2 | OCTET STRING (SIZE (0..48)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..48)) · read-only · mandatory A NULL terminated 48 byte string that contains the SNMP agent contact name. | |||||||||||||||||||||
| SsnmpSystemLocation | 1.3.6.1.4.1.19046.11.1.3.4.2.1.3 | OCTET STRING (SIZE (0..48)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..48)) · read-only · mandatory A NULL terminated 48 byte string that contains the SNMP agent location name. | |||||||||||||||||||||
| SsnmpSystemAgentTrapsDisable | 1.3.6.1.4.1.19046.11.1.3.4.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Disable or enable SNMP V1 and V3 traps.
| |||||||||||||||||||||
| NsnmpAgentCommunityConfig | 1.3.6.1.4.1.19046.11.1.3.4.2.1.5 | ||||||||||||||||||||
| SsnmpCommunityEntryCommunityName | 1.3.6.1.4.1.19046.11.1.3.4.2.1.5.1 | DisplayString (SIZE (0..15)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..15)) · read-only · mandatory SNMP Community entry name. | |||||||||||||||||||||
| SsnmpCommunityEntryCommunityIpAddress | 1.3.6.1.4.1.19046.11.1.3.4.2.1.5.2 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory SNMP Community IP address or host name. | |||||||||||||||||||||
| Ssnmpv3SystemAgentEnable | 1.3.6.1.4.1.19046.11.1.3.4.2.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Disable or enable the SNMPv3 agent.
| |||||||||||||||||||||
| NsnmpAgentUserProfileConfig | 1.3.6.1.4.1.19046.11.1.3.4.2.1.8 | ||||||||||||||||||||
| TsnmpUserProfileTable | 1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of SNMPv3 User Profile entries | |||||||||||||||||||||
| RsnmpUserProfileEntry | 1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1 | NA | mandatory | ||||||||||||||||||
| CsnmpUserProfileEntryIndex | 1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.1 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Index for SNMPv3 Agent User Profile entry. | |||||||||||||||||||||
| CsnmpUserProfileEntryAuthProt | 1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory SNMPv3 User Profile entry - Authentication Protocol supported by the user.
| |||||||||||||||||||||
| CsnmpUserProfileEntryPrivProt | 1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory SNMPv3 User Profile entry - Privacy Protocol supported by the user.
| |||||||||||||||||||||
| CsnmpUserProfileEntryViewType | 1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory SNMPv3 User Profile entry - Access level (Get) of the user.
| |||||||||||||||||||||
| CsnmpUserProfileEntryIpAddress | 1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.6 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · OCTET STRING (SIZE (0..63)) · read-only · mandatory SNMPv3 User Profile entry - IP address or host name. | |||||||||||||||||||||
| NdnsConfig | 1.3.6.1.4.1.19046.11.1.3.4.2.2 | ||||||||||||||||||||
| SdnsEnabled | 1.3.6.1.4.1.19046.11.1.3.4.2.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Disable or enable the DNS agent.
| |||||||||||||||||||||
| SdnsServerIPAddress1 | 1.3.6.1.4.1.19046.11.1.3.4.2.2.2 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the primary DNS server IP address. | |||||||||||||||||||||
| SdnsServerIPAddress2 | 1.3.6.1.4.1.19046.11.1.3.4.2.2.3 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the secondary DNS server IP address. | |||||||||||||||||||||
| SdnsServerIPAddress3 | 1.3.6.1.4.1.19046.11.1.3.4.2.2.4 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Contains the tertiary DNS server IP address. | |||||||||||||||||||||
| SdnsServerIPv6Address1 | 1.3.6.1.4.1.19046.11.1.3.4.2.2.12 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory Contains the primary IPv6 DNS server address. | |||||||||||||||||||||
| SdnsServerIPv6Address2 | 1.3.6.1.4.1.19046.11.1.3.4.2.2.13 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory Contains the secondary IPv6 DNS server address. | |||||||||||||||||||||
| SdnsServerIPv6Address3 | 1.3.6.1.4.1.19046.11.1.3.4.2.2.14 | InetAddressIPv6 | RO | mandatory | |||||||||||||||||
scalar · InetAddressIPv6 · read-only · mandatory Contains the tertiary IPv6 DNS server address. | |||||||||||||||||||||
| SdnsPriority | 1.3.6.1.4.1.19046.11.1.3.4.2.2.20 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Tells the order host names are resolved. The options are to either first resolve with an IPv6 DNS server or to first resolve with an IPv6 DNS server.
| |||||||||||||||||||||
| SdnsLXCADiscovery | 1.3.6.1.4.1.19046.11.1.3.4.2.2.21 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Disable or enable LXCA discovery using DNS SRV records.
| |||||||||||||||||||||
| NsmtpConfig | 1.3.6.1.4.1.19046.11.1.3.4.2.3 | ||||||||||||||||||||
| SsmtpServerNameOrIPAddress | 1.3.6.1.4.1.19046.11.1.3.4.2.3.1 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory A NULL terminated 64 byte string that contains the SMTP server Host name or IP address(a.b.c.d). | |||||||||||||||||||||
| SsmtpServerPort | 1.3.6.1.4.1.19046.11.1.3.4.2.3.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory SMTP server port number. | |||||||||||||||||||||
| SsmtpServerAuthentication | 1.3.6.1.4.1.19046.11.1.3.4.2.3.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Enable/disable SMTP-AUTH function.
| |||||||||||||||||||||
| SsmtpServerAuthenticationUser | 1.3.6.1.4.1.19046.11.1.3.4.2.3.4 | OCTET STRING (SIZE (0..256)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..256)) · read-only · mandatory SMTP authentication user name | |||||||||||||||||||||
| SsmtpServerAuthenticationMethod | 1.3.6.1.4.1.19046.11.1.3.4.2.3.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory SMTP authentication method , support CRAM-MD5 and PLAIN only
| |||||||||||||||||||||
| SsmtpServerReversePath | 1.3.6.1.4.1.19046.11.1.3.4.2.3.7 | OCTET STRING (SIZE (0..256)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..256)) · read-only · mandatory A NULL terminated 256 byte string that contains the SMTP Reverse Path. The user can substitute their own sender information in place of the XCC default sender information. For example [email protected] in place of the default [email protected]. | |||||||||||||||||||||
| NtcpApplicationConfig | 1.3.6.1.4.1.19046.11.1.3.4.2.4 | ||||||||||||||||||||
| SslpAddrType | 1.3.6.1.4.1.19046.11.1.3.4.2.4.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get SLP address type. Note that when slpAddrType is broadast then the multicast address in slpMulticastAddt will be ignored.
| |||||||||||||||||||||
| SslpMulticastAddr | 1.3.6.1.4.1.19046.11.1.3.4.2.4.3 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Service Locator Protocol Multicast address | |||||||||||||||||||||
| NsshServerConfig | 1.3.6.1.4.1.19046.11.1.3.4.2.4.5 | ||||||||||||||||||||
| SsshServerHostKeySize | 1.3.6.1.4.1.19046.11.1.3.4.2.4.5.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the public/private host key pair. NOTE: The XCC supports only the bits1048 value.
| |||||||||||||||||||||
| SsshServerHostKeyFingerprint | 1.3.6.1.4.1.19046.11.1.3.4.2.4.5.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The RSA fingerprint of the public part of the host key pair. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the XCC. Null Empty string if no RSA key exists. | |||||||||||||||||||||
| SsshEnable | 1.3.6.1.4.1.19046.11.1.3.4.2.4.5.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Disable/Enable SSH.
| |||||||||||||||||||||
| NsslConfig | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6 | ||||||||||||||||||||
| SsslEnableHTTPSforWeb | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get the status for web HTTPS service. To use SSL, a client web browser must be configured to use SSL3 and/or TLS. Older export-grade browsers with only SSL2 support cannot be used.
| |||||||||||||||||||||
| SsslEnableHTTPSforCIMXML | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get the status for CIM over HTTPS service.
| |||||||||||||||||||||
| SsslEnableSecureClientLDAP | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get the status of the Secure LDAP Client.
| |||||||||||||||||||||
| NsslServerCertificate | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.4 | ||||||||||||||||||||
| SsslServerCertificateStatus | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.4.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get the status of the installed HTTPS certificate. 1 = Private Key and Cert/CSR not available. 2 = Private Key and Self-signed cert installed. 3 = Private Key and CA-signed cert installed. 4 = Private Key stored, CSR available for download. 5 = Private Key and Self-signed cert installed, Private Key stored, CSR available for download. 6 = Private Key and CA-signed cert installed, Private Key stored, CSR available for download.
| |||||||||||||||||||||
| SsslServerCertificateExpirationDate | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.4.2 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory Expiration date of the installed HTTPS certificate. | |||||||||||||||||||||
| NsslLDAPTrustedCertificate | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5 | ||||||||||||||||||||
| SsslLDAPTrustedCertificate1Status | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get the status of the LDAP trusted certificate #1. 0 = certificate not installed 1 = certificate installed.
| |||||||||||||||||||||
| SsslLDAPTrustedCertificate1ExpirationDate | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.2 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory Expiration date of the LDAP trusted certificate #1 if it is installed. | |||||||||||||||||||||
| SsslLDAPTrustedCertificate2Status | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get the status of the LDAP trusted certificate #2. 0 = certificate not installed 1 = certificate installed.
| |||||||||||||||||||||
| SsslLDAPTrustedCertificate2ExpirationDate | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.4 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory Expiration date of the LDAP trusted certificate #2 if it is installed.. | |||||||||||||||||||||
| SsslLDAPTrustedCertificate3Status | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get the status of the LDAP trusted certificate #3. 0 = certificate not installed 1 = certificate installed.
| |||||||||||||||||||||
| SsslLDAPTrustedCertificate3ExpirationDate | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.6 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory Expiration date of the LDAP trusted certificate #3 if it is installed. | |||||||||||||||||||||
| SsslLDAPTrustedCertificate4Status | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.7 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get the status of the LDAP trusted certificate #4. 0 = certificate not installed 1 = certificate installed.
| |||||||||||||||||||||
| SsslLDAPTrustedCertificate4ExpirationDate | 1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.8 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory Expiration date of the LDAP trusted certificate #4 if it is installed. | |||||||||||||||||||||
| NcertDomainNames | 1.3.6.1.4.1.19046.11.1.3.4.2.4.8 | ||||||||||||||||||||
| TcertDomainNameTable | 1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory This table contains certificate domain names and status. | |||||||||||||||||||||
| RcertDomainNameEntry | 1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each row contains a certificate domain name and status.
| |||||||||||||||||||||
| CcertDomainNameIndex | 1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1.1.1 | INTEGER (1..1000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory The index number of one certificate domain name entry. | |||||||||||||||||||||
| CcertDomainName | 1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1.1.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory The Certificate Domain Name of one certificate domain name entry. | |||||||||||||||||||||
| CcertDomainNameStatus | 1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1.1.3 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory The status of the Certificate Domain Name entry. | |||||||||||||||||||||
| NskrServers | 1.3.6.1.4.1.19046.11.1.3.4.2.4.9 | ||||||||||||||||||||
| TskrServerTable | 1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory This table contains Storage Key Repository Server hostnames and ports. | |||||||||||||||||||||
| RskrServerEntry | 1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each row contains a Storage Key Repository Server hostname and port.
| |||||||||||||||||||||
| CskrServerIndex | 1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1.1.1 | INTEGER (1..1000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory The index number of one Storage Key Repository Server entry. | |||||||||||||||||||||
| CskrServerHostname | 1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1.1.2 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · OCTET STRING (SIZE (0..63)) · read-only · mandatory Storage Key Repository Server hostname or IP address. | |||||||||||||||||||||
| CskrServerPort | 1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Storage Key Repository Server port number. | |||||||||||||||||||||
| SskrDeviceGroup | 1.3.6.1.4.1.19046.11.1.3.4.2.4.9.3 | OCTET STRING (SIZE (0..17)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..17)) · read-only · mandatory An optional NULL terminated 16 character string that contains the Device Group that the server drives belong to. | |||||||||||||||||||||
| NskrClientConfigCertficate | 1.3.6.1.4.1.19046.11.1.3.4.2.4.9.4 | ||||||||||||||||||||
| SskrClientCertificateStatus | 1.3.6.1.4.1.19046.11.1.3.4.2.4.9.4.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get the status of the installed Web certificates.
1 = Private Key and Cert/CSR not available.
2 = Private Key and Self-signed cert installed.
3 = Private Key and CA-signed cert installed.
4 = Private Key stored, CSR available for download.
5 = Private Key and Self-signed cert installed, Private Key stored, CSR available for download.
6 = Private Key and CA-signed cert installed, Private Key stored, CSR available for download.
| |||||||||||||||||||||
| SskrClientCertificateExpirationDate | 1.3.6.1.4.1.19046.11.1.3.4.2.4.9.4.4 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory Expiration date of the SKR client certificate. | |||||||||||||||||||||
| SskrServerCertificateExpirationDate | 1.3.6.1.4.1.19046.11.1.3.4.2.4.9.12 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory Expiration date of the SKR Server certificate. | |||||||||||||||||||||
| NtcpPortAssignmentCfg | 1.3.6.1.4.1.19046.11.1.3.4.2.5 | ||||||||||||||||||||
| ShttpPortAssignment | 1.3.6.1.4.1.19046.11.1.3.4.2.5.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory HTTP port number. Default value is 80. Once changed, the url's have to include :port at the end. | |||||||||||||||||||||
| ShttpsPortAssignment | 1.3.6.1.4.1.19046.11.1.3.4.2.5.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory SSL port number. Default value is 443. Once changed, the url's have to include :port at the end. | |||||||||||||||||||||
| SsshLegacyCLIPortAssignment | 1.3.6.1.4.1.19046.11.1.3.4.2.5.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory SSH port number. Default value is 22. | |||||||||||||||||||||
| SsnmpAgentPortAssignment | 1.3.6.1.4.1.19046.11.1.3.4.2.5.8 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory SNMP Agent port number. Default value is 161. | |||||||||||||||||||||
| SsnmpTrapsPortAssignment | 1.3.6.1.4.1.19046.11.1.3.4.2.5.9 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory SNMP Traps port number. Default value is 162. | |||||||||||||||||||||
| SremvidPortAssignment | 1.3.6.1.4.1.19046.11.1.3.4.2.5.10 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Remote Console port number. Default value is 3900. | |||||||||||||||||||||
| ScimOverHttpsPortAssignment | 1.3.6.1.4.1.19046.11.1.3.4.2.5.12 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory CIM over Https port number. | |||||||||||||||||||||
| NldapClientCfg | 1.3.6.1.4.1.19046.11.1.3.4.2.6 | ||||||||||||||||||||
| SldapServer1NameOrIPAddress | 1.3.6.1.4.1.19046.11.1.3.4.2.6.1 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory A NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d). | |||||||||||||||||||||
| SldapServer1PortNumber | 1.3.6.1.4.1.19046.11.1.3.4.2.6.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory LDAP server port number. | |||||||||||||||||||||
| SldapServer2NameOrIPAddress | 1.3.6.1.4.1.19046.11.1.3.4.2.6.3 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory A NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d). | |||||||||||||||||||||
| SldapServer2PortNumber | 1.3.6.1.4.1.19046.11.1.3.4.2.6.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory LDAP server port number. | |||||||||||||||||||||
| SldapServer3NameOrIPAddress | 1.3.6.1.4.1.19046.11.1.3.4.2.6.5 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory A NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d). | |||||||||||||||||||||
| SldapServer3PortNumber | 1.3.6.1.4.1.19046.11.1.3.4.2.6.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory LDAP server port number. | |||||||||||||||||||||
| SldapServer4NameOrIPAddress | 1.3.6.1.4.1.19046.11.1.3.4.2.6.7 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory A NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d). | |||||||||||||||||||||
| SldapServer4PortNumber | 1.3.6.1.4.1.19046.11.1.3.4.2.6.8 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory LDAP server port number. | |||||||||||||||||||||
| SldapRootDN | 1.3.6.1.4.1.19046.11.1.3.4.2.6.9 | OCTET STRING (SIZE (0..300)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..300)) · read-only · mandatory Distinguished Name for root entry of directory tree. An example might look like dn=foobar,dn=com. | |||||||||||||||||||||
| SldapGroupFilter | 1.3.6.1.4.1.19046.11.1.3.4.2.6.11 | OCTET STRING (SIZE (0..511)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..511)) · read-only · mandatory This filter is used for group authentication. It specifies what group or groups that this MM belongs to. If left blank, group authentication is disabled. Otherwise, group authentication will be performed against the filter. The filter can be a specific group name (eg. IMMWest), a wildcard (*) which matches everything, or a wildcard with a prefix (eg. XCC*). The default filter is XCC*. After user authentication, group authentication will take place, whereby an attempt will be made to match the group or groups (that the user belongs to) to the group filter defined here. If there is no match, the user will not pass authentication and will be blocked. If there is a match, the login permissions for the user will be retrieved from the matched group(s), unless the user already has login permissions assigned directly from the user record retrieved from the LDAP server. | |||||||||||||||||||||
| SldapBindingMethod | 1.3.6.1.4.1.19046.11.1.3.4.2.6.12 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory On initial binds to the LDAP server during user authentication, there are three options: Anonymous authentication: Bind attempt is made without a client DN or password. If the bind is successful, a search will be requested in order to find an entry on the LDAP server for the user attempting to login. If an entry is found, a second attempt to bind will be attempted, this time with the user's DN and password. If this succeeds, the user is deemed to have passed the user authentication phase. Group authentication is then attempted if it is enabled. Client authentication: Bind attempt is made with client DN and password specified by this configuration parameter. If the bind is successful, we proceed as above. User Principal Name (UPN): Bind attempt is made directly with the credentials used during the login process. If this succeeds, the user is deemed to have passed the user authentication phase. Note that for Active Directory servers, the userid can have the form someuser@somedomain or simply someuser.
| |||||||||||||||||||||
| SldapClientAuthenticationDN | 1.3.6.1.4.1.19046.11.1.3.4.2.6.13 | OCTET STRING (SIZE (0..300)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..300)) · read-only · mandatory The initial bind to the LDAP server during user authentication can be performed with anonymous authentication, client based authentication, or UPN. The client based option requires a client DN and password as parameters to the bind request. These parameters are configured here. Note that the password can be left blank. | |||||||||||||||||||||
| SldapRoleBasedSecurityEnabled | 1.3.6.1.4.1.19046.11.1.3.4.2.6.15 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory A value of true for RoleBasedSecurityEnabled indicates enhanced will be used by the service processor. A value of false for RoleBasedSecurityEnabled indicates the legacy bit mask based security is being used.
| |||||||||||||||||||||
| SldapServerTargetName | 1.3.6.1.4.1.19046.11.1.3.4.2.6.16 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory When administrator chooses Enhanced Role Based Security authentication model, he can associate one XCC with one managed target object in Snap-in (one tool to configure LDAP users permission) via one target name. The XCC target name can be looked as alias of XCC, administrator can change it according to his configuration requirements. This is a string of up to 63 characters (plus the null character) | |||||||||||||||||||||
| SldapUIDsearchAttribute | 1.3.6.1.4.1.19046.11.1.3.4.2.6.17 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory When the binding method selected is Anonymous authentication or Client authentication, the initial bind to the LDAP server is followed by a search request aimed at retrieving specific information about the user, including the user's DN, login permissions, and group ownerships. In order to retrieve this information, the search request must specify the attribute name used to represent userids on that server. Specifically, this name is used as a search filter against the login id entered by the user. This attribute name is configured here. If this field is left blank, a default of uid is used during user authentication. For example, on Active Directory servers, the attribute name used for userids is often sAMAccoutName. When the binding method selected is UPN or Strict UPN, this field defaults automatically to userPrincipalName during user authentication if the userid entered has the form userid@somedomain. | |||||||||||||||||||||
| SldapGroupSearchAttribute | 1.3.6.1.4.1.19046.11.1.3.4.2.6.18 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory When the MM Group Filter name is configured, it is necessary to retrieve from the LDAP server the list of groups that a particular user belongs to. This is required to do group authentication. In order to retrieve this list, the search filter sent to the server must specify the attribute name associated with groups. This field specifies this attribute name. If this field is left blank, the attribute name in the filter will default to memberOf. | |||||||||||||||||||||
| SldapLoginPermissionAttribute | 1.3.6.1.4.1.19046.11.1.3.4.2.6.19 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory When a user successfully authenticates via a LDAP server, it is necessary to retrieve the login permissions for this user. In order to retrieve these permissions, the search filter sent to the server must specify the attribute name associated with login permissions. This field specifies this attribute name. | |||||||||||||||||||||
| SldapUseDNSOrPreConfiguredServers | 1.3.6.1.4.1.19046.11.1.3.4.2.6.20 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The MM contains a Version 2.0 LDAP Client that may be configured to provide user authentication through one or more LDAP servers. The LDAP server(s) to be used for authentication can be discovered dynamically or manually pre-configured. If the usePreConfiguredLDAPServers option is selected, up to 3 LDAP servers can be configured. Simply enter the server's IP address or hostname (assuming DNS is enabled). The port number for each server is optional. If left blank, the default value of 389 is used for non-secured LDAP connections. For secured connections, the default is 636. At least one server must be configured. If the useDNSToFindLDAPServers is selected, the mechanisms described by RFC2782 (A DNS RR for specifying the location of services) are applied to find the server(s). This is known as DNS SRV.
| |||||||||||||||||||||
| SldapDomainSource | 1.3.6.1.4.1.19046.11.1.3.4.2.6.21 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The DNS SRV request sent to the DNS server must specify a domain name. The LDAP client will determine where to get this domain name based on one of the following three options: - extractSearchDomainFromLoginID: With this option, the LDAP client will use the domain name in the login id. For example, if the login id is [email protected], the domain name equals mycompany.com. If the domain name cannot be extracted, the DNS SRV will fail, causing the user authentication to fail automatically. - useOnlyConfiguredSearchDomainBelow: With this option, the LDAP client will use the domain name configured in the Search Domain parameter. - tryLoginFirstThenConfiguredValue: With this option, the LDAP client will first attempt to extract the domain name from the login id. If this succeeds, this domain name will be used in the DNS SRV request. If there is no domain name present in the login id, the LDAP client will instead use the configured Search Domain parameter as the domain name in the DNS SRV request. If nothing is configured, user authentication will fail immediately.
| |||||||||||||||||||||
| SldapForestName | 1.3.6.1.4.1.19046.11.1.3.4.2.6.22 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory In order to discover Global Catalogs (GC), the forest name must be configured in the ForestName property. The Global Catalogs are required for users who belong to universal groups in cross-domains. In environments where cross-domain group membership does not apply, this field can be left blank. | |||||||||||||||||||||
| SldapAuthCfg | 1.3.6.1.4.1.19046.11.1.3.4.2.6.23 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory If ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize users. If it is set to 1, LDAP server is only used to authenticate users. Note:LDAP Authentication Only mode is currently supported only in an Active Directory environment.
| |||||||||||||||||||||
| SldapSearchDomain | 1.3.6.1.4.1.19046.11.1.3.4.2.6.24 | OCTET STRING (SIZE (0..64)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory This parameter may be used as the domain name in the DNS SRV request, depending on how the Domain Source parameter is configured. | |||||||||||||||||||||
| SldapServiceName | 1.3.6.1.4.1.19046.11.1.3.4.2.6.25 | OCTET STRING (SIZE (0..16)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..16)) · read-only · mandatory The DNS SRV request sent to the DNS server must also specify a service name. The configured value will be used for this purpose. If left blank, the default value used is 'ldap'. Note that the DNS SRV request must also specify a protocol name. This defaults to 'tcp' and is not configurable. | |||||||||||||||||||||
| NntpConfig | 1.3.6.1.4.1.19046.11.1.3.4.2.8 | ||||||||||||||||||||
| SntpEnable | 1.3.6.1.4.1.19046.11.1.3.4.2.8.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Disable/Enable the NTP client. The client will update the XCC system clock at the frequency specified.
| |||||||||||||||||||||
| SntpIpAddressHostname1 | 1.3.6.1.4.1.19046.11.1.3.4.2.8.2 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory First NTP server's IP address or hostname if DNS is enabled and configured. | |||||||||||||||||||||
| SntpUpdateFrequency | 1.3.6.1.4.1.19046.11.1.3.4.2.8.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The frequency in minutes that the NTP service runs. The value range is 3 to 1440. | |||||||||||||||||||||
| SntpIpAddressHostname2 | 1.3.6.1.4.1.19046.11.1.3.4.2.8.4 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory Second NTP server's IP address or hostname if DNS is enabled and configured. | |||||||||||||||||||||
| SntpIpAddressHostname3 | 1.3.6.1.4.1.19046.11.1.3.4.2.8.6 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory Third NTP server's IP address or hostname if DNS is enabled and configured. | |||||||||||||||||||||
| SntpIpAddressHostname4 | 1.3.6.1.4.1.19046.11.1.3.4.2.8.7 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory Fourth NTP server's IP address or hostname if DNS is enabled and configured. | |||||||||||||||||||||
| NipmiConfig | 1.3.6.1.4.1.19046.11.1.3.4.2.10 | ||||||||||||||||||||
| SipmiStatus | 1.3.6.1.4.1.19046.11.1.3.4.2.10.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get the status of IPMI service
| |||||||||||||||||||||
| NcimxmlConfig | 1.3.6.1.4.1.19046.11.1.3.4.2.11 | ||||||||||||||||||||
| ScimxmlStatus | 1.3.6.1.4.1.19046.11.1.3.4.2.11.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get the status of CIM service.
| |||||||||||||||||||||
| NrestConfig | 1.3.6.1.4.1.19046.11.1.3.4.2.12 | ||||||||||||||||||||
| SrestStatus | 1.3.6.1.4.1.19046.11.1.3.4.2.12.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get the status of the REST over HTTPS.
| |||||||||||||||||||||
| SxccVersionCheck | 1.3.6.1.4.1.19046.11.1.3.7 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get the XCC version type.
| |||||||||||||||||||||
| NgeneralSystemSettings | 1.3.6.1.4.1.19046.11.1.4 | ||||||||||||||||||||
| NserverTimers | 1.3.6.1.4.1.19046.11.1.4.1 | ||||||||||||||||||||
| SoSHang | 1.3.6.1.4.1.19046.11.1.4.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Number, in 1 second intervals, the XCC will check to insure the OS is operating properly. If the operating system fails to respond within 6 seconds to one of these checks, the remote supervisor adapter will generate an O/S Timeout alert(if enabled) and automatically restart the system one time. Once the system is restarted, the O/S Watchdog is automatically disabled until the operating system is shutdown and the server is power cycled.
| |||||||||||||||||||||
| SoSLoader | 1.3.6.1.4.1.19046.11.1.4.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Number in 30 second intervals the remote XCC will wait between completion of POST and the end of loading the OS. If this interval is exceeded, the XCC will generate a Loader Timeout alert(if enabled) and automatically restart the system one time. Once the system is restarted, the Loader Timeout is automatically disabled until the operating system is shutdown and the server is power cycled.
| |||||||||||||||||||||
| SnetworkPXEboot | 1.3.6.1.4.1.19046.11.1.4.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Modify the system's boot sequence for the next system restart in order to attempt a PXE/DHCP network boot. The system's boot sequence(set via the BIOS settings) will be altered only if the system is not under PAP (Privileged Access Protection).
| |||||||||||||||||||||
| NsystemPower | 1.3.6.1.4.1.19046.11.1.5 | ||||||||||||||||||||
| NpowerStatistics | 1.3.6.1.4.1.19046.11.1.5.1 | ||||||||||||||||||||
| ScurrentSysPowerStatus | 1.3.6.1.4.1.19046.11.1.5.1.1 | INTEGER | RO | mandatory | poweredOn(255) | ||||||||||||||||
scalar · INTEGER · read-only · mandatory Indicates if the system is currently powered on, off, or in sleep state.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerOnHours | 1.3.6.1.4.1.19046.11.1.5.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Number of hours the system has been powered on. | |||||||||||||||||||||
| SrestartCount | 1.3.6.1.4.1.19046.11.1.5.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Number of times the system has been restarted. | |||||||||||||||||||||
| SsystemState | 1.3.6.1.4.1.19046.11.1.5.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Shows the current operational state of the system.
| |||||||||||||||||||||
| NpowerSysConfig | 1.3.6.1.4.1.19046.11.1.5.2 | ||||||||||||||||||||
| SpowerSysOffDelay | 1.3.6.1.4.1.19046.11.1.5.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of 1 second interval the XCC will wait before powering off the system.
| |||||||||||||||||||||
| SpowerSysOnClockSetting | 1.3.6.1.4.1.19046.11.1.5.2.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The clock setting used to determine when the XCC will power on the system. For example the value '03/04/2001,06:00' means that the system will power on March 4, 2001 at 06:00AM. | |||||||||||||||||||||
| NpowerCyclingSchedule | 1.3.6.1.4.1.19046.11.1.5.5 | ||||||||||||||||||||
| SschedulePowerOffWithOsShutdown | 1.3.6.1.4.1.19046.11.1.5.5.1 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory Power Off the system after performing a OS shutdown at specified time and day of the week. Example: Monday,09:00, To reset, the value as Never,00:00. | |||||||||||||||||||||
| SschedulePowerOnSystem | 1.3.6.1.4.1.19046.11.1.5.5.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory Power On the system at specified time and day of the week. Example: Monday,09:00. To reset, the value as Never,00:00. | |||||||||||||||||||||
| NserviceAdvisor | 1.3.6.1.4.1.19046.11.1.8 | ||||||||||||||||||||
| NautoCallHomeSetup | 1.3.6.1.4.1.19046.11.1.8.1 | ||||||||||||||||||||
| SacceptLicenseAgreement | 1.3.6.1.4.1.19046.11.1.8.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Accept Terms and Conditions of Service Advisor. The user will have to accept the terms and conditions before Service Advisor can send diagnostic data to support personnel. If XCC configuration is reset to defaults, the user will have to accept the terms and conditions again before they can enable Service Advisor. For more information, please refer to the BladeCenter User's Guide. It will return disabled(0) or enabled(1), depending upon the current state.
| |||||||||||||||||||||
| SserviceAdvisorEnable | 1.3.6.1.4.1.19046.11.1.8.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Disable/Enable Call Home Support. The User Agreement must be accepted and the contact information must be set before the Call Home Support function of Service Advisor can be enabled.
| |||||||||||||||||||||
| NserviceSupportCenter | 1.3.6.1.4.1.19046.11.1.8.2 | ||||||||||||||||||||
| SlenovoSupportCenter | 1.3.6.1.4.1.19046.11.1.8.2.1 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The country code for the Support Center. 2 character ISO country code. | |||||||||||||||||||||
| NcontactInformation | 1.3.6.1.4.1.19046.11.1.8.3 | ||||||||||||||||||||
| ScompanyName | 1.3.6.1.4.1.19046.11.1.8.3.1 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The organization/company name of the contact person. 1-30 characters. | |||||||||||||||||||||
| ScontactName | 1.3.6.1.4.1.19046.11.1.8.3.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The name of the contact person.1-30 characters. | |||||||||||||||||||||
| SphoneNumber | 1.3.6.1.4.1.19046.11.1.8.3.3 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The phone of the contact person. 5-30 characters. | |||||||||||||||||||||
| SemailAddress | 1.3.6.1.4.1.19046.11.1.8.3.4 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The email of the contact person. It must contain '@' and dot '.' in form userid@hostname (30 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters. | |||||||||||||||||||||
| Saddress | 1.3.6.1.4.1.19046.11.1.8.3.5 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The address of the machine location. The information in this field should be of sufficient detail to allow someone to quickly find the chassis when necessary. 1-30 characters. | |||||||||||||||||||||
| Scity | 1.3.6.1.4.1.19046.11.1.8.3.6 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The city of the machine location. 1-30 characters. | |||||||||||||||||||||
| Sstate | 1.3.6.1.4.1.19046.11.1.8.3.7 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The state of the machine location. 2-3 characters. | |||||||||||||||||||||
| SpostalCode | 1.3.6.1.4.1.19046.11.1.8.3.8 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid. | |||||||||||||||||||||
| SphoneExtension | 1.3.6.1.4.1.19046.11.1.8.3.9 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The phone extension of the contact person. 30 characters maximum. | |||||||||||||||||||||
| SaltContactName | 1.3.6.1.4.1.19046.11.1.8.3.10 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The name of the alternate contact person. 1-30 characters. | |||||||||||||||||||||
| SaltPhoneNumber | 1.3.6.1.4.1.19046.11.1.8.3.11 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The phone of the alternate contact person. 5-30 characters. | |||||||||||||||||||||
| SaltPhoneExtension | 1.3.6.1.4.1.19046.11.1.8.3.12 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The phone extension of the alternate contact person. 30 characters maximum. | |||||||||||||||||||||
| SaltEmailAddress | 1.3.6.1.4.1.19046.11.1.8.3.13 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (30 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters. | |||||||||||||||||||||
| SmachineLocationPhoneNumber | 1.3.6.1.4.1.19046.11.1.8.3.14 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory The phone of the physical location where the compuer system resides. 5-30 characters. | |||||||||||||||||||||
| NhttpProxyConfig | 1.3.6.1.4.1.19046.11.1.8.4 | ||||||||||||||||||||
| ShttpProxyEnable | 1.3.6.1.4.1.19046.11.1.8.4.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Disable/Enable of the HTTP Proxy. HTTP Proxy is used by the XCC when it is not connected to the internet directly.
| |||||||||||||||||||||
| ShttpProxyLocation | 1.3.6.1.4.1.19046.11.1.8.4.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory Fully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters. | |||||||||||||||||||||
| ShttpProxyPort | 1.3.6.1.4.1.19046.11.1.8.4.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The port number of the HTTP Proxy. An integer value from 1 to 65535. | |||||||||||||||||||||
| ShttpProxyUserName | 1.3.6.1.4.1.19046.11.1.8.4.4 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory User Name of the HTTP Proxy. A maximum of 30 characters string without spaces. | |||||||||||||||||||||
| ShttpProxyPassword | 1.3.6.1.4.1.19046.11.1.8.4.5 | OCTET STRING | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING · read-only · mandatory Password of the HTTP Proxy. A maximum of 15 characters string without spaces. | |||||||||||||||||||||
| NactivityLogs | 1.3.6.1.4.1.19046.11.1.8.5 | ||||||||||||||||||||
| TactivityLogTable | 1.3.6.1.4.1.19046.11.1.8.5.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Service Advisor Activity Log entries information. This table displays events that were generated by the system or user that are called home. The entries are displayed in reverse chronological order (most recent call home entry first). For any events that happen with same Date/Time, only one event will be called home. If a call home event that is already in the activity log is triggered again on the same event source, it will not be called home again unless the prior entry has been acknowledged as corrected or, in the case of XCC, 120 hours (5 days) have passed since it initially occurred and was called home. | |||||||||||||||||||||
| RactivityLogEntry | 1.3.6.1.4.1.19046.11.1.8.5.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Activity Log table entry. Each entry has the result of the call-home attempt, the service number assigned for the issue by the Support Center, the event ID, event source, date and time that event occured, and a text message.
| |||||||||||||||||||||
| CactivityLogIndex | 1.3.6.1.4.1.19046.11.1.8.5.1.1.1 | INTEGER (1..1000000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000000) · read-only · mandatory The Activity Log index number. For consistent results, view as a table and not as individual entries. | |||||||||||||||||||||
| CactivityLogString | 1.3.6.1.4.1.19046.11.1.8.5.1.1.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory A string of data detailing one Activity Log entry. The text message is from the original entry in the event log. For consistent results, view as a table and not as individual entries. | |||||||||||||||||||||
| CactivityLogAcknowledge | 1.3.6.1.4.1.19046.11.1.8.5.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to certain events to indicate their awareness of the issue. Checking the acknowledge flag will not cause the event to be removed from the log or close the ticket at the Support Center. This log is not cleared, so the acknowledge flag can be used to indicate a problem can be ignored. This field can be also used to override the 120 hour (5 day) filtering of reports via the Support Center or FTP/TFTP Server of Service Data. For consistent results, view as a table and not as individual entries.
| |||||||||||||||||||||
| CactivityLogAttribute | 1.3.6.1.4.1.19046.11.1.8.5.1.1.4 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory A string of data detailing one Activity Log entry's attribute. It contains states of both calling the Support Center and FTP/TFTP Server. A PENDING indicates that the system is preparing for the event to be called home by collecting data about the systems state. A SUCCESS state indicates that the problem was successfully transmitted to the Support Center or FTP/TFTP Server. A DISABLED state indicates that Service Advisor has disabled calling the Support Center or FTP/TFTP Server while the hardware event is detected. A NOT SENT state indicates that the serviceable event was not sent to prevent the same event from being sent repeatedly. The FAILED state indicates that the attempt to transmit the event information was not successful. Additional information may be found in the Event Log. The service number is similar to a ticket number that can be used as a reference to the issue reported by the machine when contacting the Support Center. The event ID, event source, date and time are all information from the original entry in the event log. The acknowledged as corrected field is a reminder to certain events to indicate their awareness of the issue. For consistent results, view as a table and not as individual entries. | |||||||||||||||||||||
| NautoFTPSetup | 1.3.6.1.4.1.19046.11.1.8.6 | ||||||||||||||||||||
| SautoFTPCallMode | 1.3.6.1.4.1.19046.11.1.8.6.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This field specifies the automated problem reporting mode. Automated problem reporting mode allows the XCC to automatically put service data to a specified server when a call home event is detected. For any call home events that happen with same Date/Time, only one event will be reported. The system will also wait for an interval of 120 hours (5 days) before another identical event can be sent for the same failed component.
| |||||||||||||||||||||
| SautoFTPCallAddr | 1.3.6.1.4.1.19046.11.1.8.6.2 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory This field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address. | |||||||||||||||||||||
| SautoFTPCallPort | 1.3.6.1.4.1.19046.11.1.8.6.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This field specifies the port on remote FTP/TFTP server for data transmission. | |||||||||||||||||||||
| SautoFTPCallUserID | 1.3.6.1.4.1.19046.11.1.8.6.4 | OCTET STRING (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..63)) · read-only · mandatory This field specifies the user account to login remote FTP server. | |||||||||||||||||||||
| NcallHomeExclusionEvents | 1.3.6.1.4.1.19046.11.1.8.7 | ||||||||||||||||||||
| TreadCallHomeExclusionEventTable | 1.3.6.1.4.1.19046.11.1.8.7.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table of Call Home Exclusion Event entries information. | |||||||||||||||||||||
| RreadCallHomeExclusionEventEntry | 1.3.6.1.4.1.19046.11.1.8.7.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Call Home Exclusion Event table entry | |||||||||||||||||||||
| CreadCallHomeExclusionEventIndex | 1.3.6.1.4.1.19046.11.1.8.7.1.1.1 | INTEGER (1..1000) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1000) · read-only · mandatory The index number of one Call Home Exclusion Event. For consistent results, view as a table and not as individual entries. | |||||||||||||||||||||
| CreadCallHomeExclusionEventID | 1.3.6.1.4.1.19046.11.1.8.7.1.1.2 | OCTET STRING | RO | mandatory | |||||||||||||||||
column · OCTET STRING · read-only · mandatory The Event ID of one Call Home Exclusion Event entry. For consistent results, view as a table and not as individual entries. | |||||||||||||||||||||
| NsupportProcessor | 1.3.6.1.4.1.19046.11.1.158 | ||||||||||||||||||||