MIB Browser

LCOS-SX-GENERAL-MIB

LANCOM Systems
Management information base definitions
Organization
LANCOM Systems GmbH
Root OID
1.3.6.1.4.1.2356.100
Last updated
Objects
66
Source
Show full MIB
snmptranslate -m LCOS-SX-GENERAL-MIB -Tp
snmpwalk -v2c -c <community> -m LCOS-SX-GENERAL-MIB <host> 1.3.6.1.4.1.2356.100

Imports

SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIBits, Counter64, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION

OID tree

NameOIDTypeAccessStatusExample
IlcosSXGeneral1.3.6.1.4.1.2356.100
NlcsNotificationGrp1.3.6.1.4.1.2356.100.0
NlcsTraps1.3.6.1.4.1.2356.100.0.1
!lcsTrapsTemperatureStateChange1.3.6.1.4.1.2356.100.0.1.100
!lcsTrapsFanStateChange1.3.6.1.4.1.2356.100.0.1.101
!lcsTrapsPSUStateChange1.3.6.1.4.1.2356.100.0.1.102
NlcsNotificationVars1.3.6.1.4.1.2356.100.0.2
SlcsNotificationStateChangeEvent1.3.6.1.4.1.2356.100.0.2.100INTEGERAN
SlcsNotificationTemperatureStatusCurrent1.3.6.1.4.1.2356.100.0.2.101MonitoringTempSensorStatusAN
SlcsNotificationTemperatureStatusPrevious1.3.6.1.4.1.2356.100.0.2.102MonitoringTempSensorStatusAN
NlcsStatus1.3.6.1.4.1.2356.100.1
NlcsMonitoring1.3.6.1.4.1.2356.100.1.1
TlcsMonitoringTempSensorsTable1.3.6.1.4.1.2356.100.1.1.1NA
RlcsMonitoringTempSensorsTableEntry1.3.6.1.4.1.2356.100.1.1.1.1NA
ClcsMonitoringTempSensorUnitIndex1.3.6.1.4.1.2356.100.1.1.1.1.1Unsigned32 (0..12)RO1
ClcsMonitoringTempSensorIndex1.3.6.1.4.1.2356.100.1.1.1.1.2Unsigned32 (0..15)RO0
ClcsMonitoringTempSensorDescription1.3.6.1.4.1.2356.100.1.1.1.1.3DisplayStringRO43:68:69:70:73:65:74:00
ClcsMonitoringTempSensorType1.3.6.1.4.1.2356.100.1.1.1.1.4MonitoringSensorTypeRO1
ClcsMonitoringTempSensorState1.3.6.1.4.1.2356.100.1.1.1.1.5MonitoringTempSensorStatusRO1
ClcsMonitoringTempSensorTemperature1.3.6.1.4.1.2356.100.1.1.1.1.6Integer32RO48
TlcsMonitoringTempUnitTable1.3.6.1.4.1.2356.100.1.1.2NA
RlcsMonitoringTempUnitEntry1.3.6.1.4.1.2356.100.1.1.2.1NA
ClcsMonitoringTempUnitIndex1.3.6.1.4.1.2356.100.1.1.2.1.1Unsigned32 (1..12)RO
ClcsMonitoringTempUnitState1.3.6.1.4.1.2356.100.1.1.2.1.2MonitoringTempSensorStatusRO
ClcsMonitoringTempUnitTemperature1.3.6.1.4.1.2356.100.1.1.2.1.3Integer32RO
TlcsMonitoringFansTable1.3.6.1.4.1.2356.100.1.1.3NA
RlcsMonitoringFansTableEntry1.3.6.1.4.1.2356.100.1.1.3.1NA
ClcsMonitoringFanUnitIndex1.3.6.1.4.1.2356.100.1.1.3.1.1Unsigned32 (0..12)RO1
ClcsMonitoringFanIndex1.3.6.1.4.1.2356.100.1.1.3.1.2Unsigned32 (0..15)RO0
ClcsMonitoringFanDescription1.3.6.1.4.1.2356.100.1.1.3.1.3DisplayStringRO46:61:6e:20:31:00
ClcsMonitoringFanType1.3.6.1.4.1.2356.100.1.1.3.1.4MonitoringSensorTypeRO1
ClcsMonitoringFanState1.3.6.1.4.1.2356.100.1.1.3.1.5MonitoringModuleStatusRO2
SlcsMonitoringFanSpeed1.3.6.1.4.1.2356.100.1.1.3.1.6Gauge32RO3947
TlcsMonitoringPSUTable1.3.6.1.4.1.2356.100.1.1.4NA
RlcsMonitoringPSUTableEntry1.3.6.1.4.1.2356.100.1.1.4.1NA
ClcsMonitoringPSUUnitIndex1.3.6.1.4.1.2356.100.1.1.4.1.1Unsigned32 (0..12)RO1
ClcsMonitoringPSUIndex1.3.6.1.4.1.2356.100.1.1.4.1.2Unsigned32 (0..15)RO0
ClcsMonitoringPSUDescription1.3.6.1.4.1.2356.100.1.1.4.1.3DisplayStringRO50:53:2d:31:00
ClcsMonitoringPSUType1.3.6.1.4.1.2356.100.1.1.4.1.4MonitoringSensorTypeRO1
ClcsMonitoringPSUState1.3.6.1.4.1.2356.100.1.1.4.1.5MonitoringModuleStatusRO4
NlcsConfiguration1.3.6.1.4.1.2356.100.2
NlcsLMC1.3.6.1.4.1.2356.100.2.1500
SlcsLMCOperating1.3.6.1.4.1.2356.100.2.1500.1Unsigned32RW
SlcsLMCConfigViaDHCP1.3.6.1.4.1.2356.100.2.1500.2Unsigned32RW
SlcsLMCDomain1.3.6.1.4.1.2356.100.2.1500.3DisplayStringRW
SlcsLMCAutoRenew1.3.6.1.4.1.2356.100.2.1500.4Unsigned32RW
SlcsLMCRolloutProjectID1.3.6.1.4.1.2356.100.2.1500.5DisplayStringRW
SlcsLMCRolloutLocationID1.3.6.1.4.1.2356.100.2.1500.6DisplayStringRW
SlcsLMCRolloutRole1.3.6.1.4.1.2356.100.2.1500.7DisplayStringRW
SlcsLMCZeroTouchSupport1.3.6.1.4.1.2356.100.2.1500.50Unsigned32RO
SlcsLMCPairingTokenPresent1.3.6.1.4.1.2356.100.2.1500.51Unsigned32RO
SlcsLMCManagementStatus1.3.6.1.4.1.2356.100.2.1500.53LMCStatusRO
SlcsLMCControlStatus1.3.6.1.4.1.2356.100.2.1500.54LMCStatusRO
SlcsLMCMonitoringStatus1.3.6.1.4.1.2356.100.2.1500.55LMCStatusRO
SlcsLMCConfigModified1.3.6.1.4.1.2356.100.2.1500.57Unsigned32RO
SlcsLMCDeviceID1.3.6.1.4.1.2356.100.2.1500.58DisplayStringRO
SlcsLMCStackingStatus1.3.6.1.4.1.2356.100.2.1500.59Unsigned32RO
SlcsLMCStatusRTT1.3.6.1.4.1.2356.100.2.1500.100Unsigned32RO
TlcsLMCTransportStatusTable1.3.6.1.4.1.2356.100.2.1500.101NA
RlcsLMCTransportStatusTableEntry1.3.6.1.4.1.2356.100.2.1500.101.1NA
ClcsLMCTransportStatusTransportNumberIndex1.3.6.1.4.1.2356.100.2.1500.101.1.1Integer32 (0..2147483647)NA
ClcsLMCTransportStatusServiceName1.3.6.1.4.1.2356.100.2.1500.101.1.2DisplayStringRO
ClcsLMCTransportStatusHttpRequests1.3.6.1.4.1.2356.100.2.1500.101.1.3Counter64RO
ClcsLMCTransportStatusHttpRequestsErrors1.3.6.1.4.1.2356.100.2.1500.101.1.4Counter64RO
ClcsLMCTransportStatusTXBytes1.3.6.1.4.1.2356.100.2.1500.101.1.5Counter64RO
ClcsLMCTransportStatusRXBytes1.3.6.1.4.1.2356.100.2.1500.101.1.7Counter64RO

Textual conventions

LMCStatus INTEGER

authenticationError(11) certificateError(15) certificateStorageError(13) deactivatedNoActivationCode(16) disabled(2) disabledByWLC(3) dnsError(7) error(12) httpConnectionError(6) httpProtocolError(5) memoryError(8) notYet(9) operating(4) paired(1) pairedAndClaimed(14) redirect(10) unpaired(0)

Management, Monitoring and Control Status.
MonitoringModuleStatus INTEGER

failed(3) incompatible(7) nopower(5) notpowering(6) notpresent(1) operational(2) powering(4) present(9) warning(8)

Module (fan, PSU) status values.
MonitoringSensorType INTEGER

fixed(1) fixedAC(3) fixedDC(5) removable(2) removableAC(6) removableDC(4)

Sensor type values.
MonitoringTempSensorStatus INTEGER

critical(3) low(0) normal(1) notoperational(6) notpresent(5) shutdown(4) warning(2)

Temperatur sensor status values.

Traps / Notifications