JUNIPER-SRX5000-SPU-MONITORING-MIB
Juniper Networks, Inc.This is Juniper Networks' implementation of enterprise specific MIB for SRX5000 SPU monitoring.
snmptranslate -m JUNIPER-SRX5000-SPU-MONITORING-MIB -Tpsnmpwalk -v2c -c <community> -m JUNIPER-SRX5000-SPU-MONITORING-MIB <host> 1.3.6.1.4.1.2636.3.39.1.12.1Imports
| HCNUM-TC | CounterBasedGauge64 |
|---|---|
| JUNIPER-JS-SMI | jnxJsSPUMonitoringRoot |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IjnxJsSPUMonitoringMIB | 1.3.6.1.4.1.2636.3.39.1.12.1 | ||||||||||||||||||||
identity This is Juniper Networks' implementation of enterprise specific MIB for SRX5000 SPU monitoring. | |||||||||||||||||||||
| TjnxJsSPUMonitoringObjectsTable | 1.3.6.1.4.1.2636.3.39.1.12.1.1 | NA | |||||||||||||||||||
table · not-accessible · current This table exposes SPUs utilization statistics. | |||||||||||||||||||||
| RjnxJsSPUMonitoringObjectsEntry | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1 | NA | |||||||||||||||||||
row · not-accessible · current Each entry collects CPU/Memory utilization for a SPU. | |||||||||||||||||||||
| CjnxJsSPUMonitoringIndex | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.1 | Unsigned32 | NA | ||||||||||||||||||
column · Unsigned32 · not-accessible · current SPU's overall index in platform. | |||||||||||||||||||||
| CjnxJsSPUMonitoringFPCIndex | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.2 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current Which FPC SPU is on. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringSPUIndex | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.3 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current SPU'Index inside the FPC. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringCPUUsage | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.4 | Unsigned32 | RO | 4 | |||||||||||||||||
column · Unsigned32 · read-only · current Current SPU(CPU) Utilization in percentage.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringMemoryUsage | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.5 | Unsigned32 | RO | 67 | |||||||||||||||||
column · Unsigned32 · read-only · current Current memory usage of SPU(CPU) in percentage.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringCurrentFlowSession | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.6 | Unsigned32 | RO | 13153 | |||||||||||||||||
column · Unsigned32 · read-only · current Current flow session number of SPU. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringMaxFlowSession | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.7 | Unsigned32 | RO | 131072 | |||||||||||||||||
column · Unsigned32 · read-only · current Max flow session number of SPU. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringCurrentCPSession | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.8 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current Current CP session number of SPU. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringMaxCPSession | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.9 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current Max CP session number of SPU. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringNodeIndex | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.10 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current This attribute is used to identify a chassis. A chassis can be configured in a single or cluster mode. When it is in a cluster mode, the chassis can be denote as a cluster node. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringNodeDescr | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.11 | DisplayString (SIZE (1..255)) | RO | single | |||||||||||||||||
column · DisplayString (SIZE (1..255)) · read-only · current This attribute is used to describe the chassis/cluster node information. Chassis can be configured as a single, or cluster node. When it is cluster mode, the chassis can be denoted as a cluster node. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringFlowSessIPv4 | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.12 | Unsigned32 | RO | 13000 | |||||||||||||||||
column · Unsigned32 · read-only · current Current IPv4 flow session number of SPU. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringFlowSessIPv6 | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.13 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current Current IPv6 flow session number of SPU. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringCPSessIPv4 | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.14 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current Current IPv4 CP session number of SPU. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringCPSessIPv6 | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.15 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current Current IPv6 CP session number of SPU. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CjnxJsSPUMonitoringSPUThreadsNumber | 1.3.6.1.4.1.2636.3.39.1.12.1.1.1.16 | Unsigned32 | RO | 0 | |||||||||||||||||
column · Unsigned32 · read-only · current Number of threads for an SPU. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SjnxJsSPUMonitoringCurrentTotalSession | 1.3.6.1.4.1.2636.3.39.1.12.1.2 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current System level total session in use. | |||||||||||||||||||||
| SjnxJsSPUMonitoringMaxTotalSession | 1.3.6.1.4.1.2636.3.39.1.12.1.3 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current System level max session possible. | |||||||||||||||||||||
| TjnxSPUClusterObjectsTable | 1.3.6.1.4.1.2636.3.39.1.12.1.4 | NA | |||||||||||||||||||
table · not-accessible · current This table exposes SPU monitoring objects in HA cluster. | |||||||||||||||||||||
| RjnxSPUClusterObjectsEntry | 1.3.6.1.4.1.2636.3.39.1.12.1.4.1 | NA | |||||||||||||||||||
row · not-accessible · current Each entry collects SPU monitoring contents in HA cluster. | |||||||||||||||||||||
| CjnxJsClusterMonitoringNodeIndex | 1.3.6.1.4.1.2636.3.39.1.12.1.4.1.1 | Unsigned32 | NA | ||||||||||||||||||
column · Unsigned32 · not-accessible · current This attribute is used to identify a chassis. A chassis can be configured in a single or cluster mode. When it is in a cluster mode, the chassis can be denote as a cluster node. | |||||||||||||||||||||
| CjnxJsClusterMonitoringNodeDescr | 1.3.6.1.4.1.2636.3.39.1.12.1.4.1.2 | DisplayString (SIZE (1..255)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..255)) · read-only · current This attribute is used to describe the chassis/cluster node information. Chassis can be configured as a single, or cluster node. When it is cluster mode, the chassis can be denoted as a cluster node. | |||||||||||||||||||||
| CjnxJsNodeCurrentTotalSession | 1.3.6.1.4.1.2636.3.39.1.12.1.4.1.3 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current Node total session in use. | |||||||||||||||||||||
| CjnxJsNodeMaxTotalSession | 1.3.6.1.4.1.2636.3.39.1.12.1.4.1.4 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current Node max session possible. | |||||||||||||||||||||
| CjnxJsNodeSessionCreationPerSecond | 1.3.6.1.4.1.2636.3.39.1.12.1.4.1.5 | CounterBasedGauge64 | RO | ||||||||||||||||||
column · CounterBasedGauge64 · read-only · current Node average session created in last 96 seconds. | |||||||||||||||||||||
| CjnxJsNodeSessCreationPerSecIPv4 | 1.3.6.1.4.1.2636.3.39.1.12.1.4.1.6 | CounterBasedGauge64 | RO | ||||||||||||||||||
column · CounterBasedGauge64 · read-only · current Node average IPv4 session created in last 96 seconds. | |||||||||||||||||||||
| CjnxJsNodeSessCreationPerSecIPv6 | 1.3.6.1.4.1.2636.3.39.1.12.1.4.1.7 | CounterBasedGauge64 | RO | ||||||||||||||||||
column · CounterBasedGauge64 · read-only · current Node average IPv6 session created in last 96 seconds. | |||||||||||||||||||||
| CjnxJsNodeCurrentTotalSessIPv4 | 1.3.6.1.4.1.2636.3.39.1.12.1.4.1.8 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current Node total IPv4 session in use. | |||||||||||||||||||||
| CjnxJsNodeCurrentTotalSessIPv6 | 1.3.6.1.4.1.2636.3.39.1.12.1.4.1.9 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current Node total IPv6 session in use. | |||||||||||||||||||||
| SjnxJsSPUMonitoringTotalSessIPv4 | 1.3.6.1.4.1.2636.3.39.1.12.1.5 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current System level total IPv4 session in use. | |||||||||||||||||||||
| SjnxJsSPUMonitoringTotalSessIPv6 | 1.3.6.1.4.1.2636.3.39.1.12.1.6 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current System level total IPv6 session in use. | |||||||||||||||||||||
| TjnxJsSPUMonitoringSPUThreadsTable | 1.3.6.1.4.1.2636.3.39.1.12.1.7 | NA | |||||||||||||||||||
table · not-accessible · current This table exposes threads utilization statistics for an SPU. | |||||||||||||||||||||
| RjnxJsSPUMonitoringSPUThreadsEntry | 1.3.6.1.4.1.2636.3.39.1.12.1.7.1 | NA | |||||||||||||||||||
row · not-accessible · current Entry collects CPU utilization statistics for a thread. | |||||||||||||||||||||
| CjnxJsSPUMonitoringSPUThreadIndex | 1.3.6.1.4.1.2636.3.39.1.12.1.7.1.1 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current Thread index on an SPU. | |||||||||||||||||||||
| CjnxJsSPUMonitoringSPUThreadLastMinUsage | 1.3.6.1.4.1.2636.3.39.1.12.1.7.1.2 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current Thread utilization of last minute. | |||||||||||||||||||||
| CjnxJsSPUMonitoringSPUThreadLastHourUsage | 1.3.6.1.4.1.2636.3.39.1.12.1.7.1.3 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current Thread utilization of last hour. | |||||||||||||||||||||
| CjnxJsSPUMonitoringSPUThreadLastDayUsage | 1.3.6.1.4.1.2636.3.39.1.12.1.7.1.4 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current Thread utilization of last day. | |||||||||||||||||||||
| NjnxJsResManTrapVars | 1.3.6.1.4.1.2636.3.39.1.12.1.8 | ||||||||||||||||||||
| SjnxJsResManCPUThreadIndex | 1.3.6.1.4.1.2636.3.39.1.12.1.8.1 | Unsigned32 (0..100) | AN | ||||||||||||||||||
scalar · Unsigned32 (0..100) · accessible-for-notify · current The CPU Thread index | |||||||||||||||||||||
| SjnxJsResManCPUUtil | 1.3.6.1.4.1.2636.3.39.1.12.1.8.2 | Unsigned32 (0..100) | AN | ||||||||||||||||||
scalar · Unsigned32 (0..100) · accessible-for-notify · current The CPU utilization in percentage. | |||||||||||||||||||||
| SjnxJsResManResourceUtil | 1.3.6.1.4.1.2636.3.39.1.12.1.8.3 | Unsigned32 (0..100) | AN | ||||||||||||||||||
scalar · Unsigned32 (0..100) · accessible-for-notify · current The Resource utilization in percentage. | |||||||||||||||||||||
| SjnxJsResManFPCIndex | 1.3.6.1.4.1.2636.3.39.1.12.1.8.4 | Unsigned32 | AN | ||||||||||||||||||
scalar · Unsigned32 · accessible-for-notify · current Which FPC SPU is on. | |||||||||||||||||||||
| SjnxJsResManSPUIndex | 1.3.6.1.4.1.2636.3.39.1.12.1.8.5 | Unsigned32 | AN | ||||||||||||||||||
scalar · Unsigned32 · accessible-for-notify · current SPU'Index inside the FPC. | |||||||||||||||||||||
| NjnxJsResManNotifications | 1.3.6.1.4.1.2636.3.39.1.12.1.9 | ||||||||||||||||||||
| !jnxJsResManCPUThresholdStatus | 1.3.6.1.4.1.2636.3.39.1.12.1.9.1 | ||||||||||||||||||||
notification · current The Resource Manager CPU untilization threshold status
trap signifies that the CPU load on system has bypassed a
certain percentage, or clear of that percentage.
jnxJsResManCPUThreadIndex: Thread index on an SPU, if thread
affinity, else 0
jnxJsResManCPUUtil is the weighted percentage of utilization
of the CPU. | |||||||||||||||||||||
| !jnxJsResManSessionThresholdStatus | 1.3.6.1.4.1.2636.3.39.1.12.1.9.2 | ||||||||||||||||||||
notification · current The Resource Manager Session untilization threshold status
trap signifies that the Session load on system has bypassed a
certain percentage
jnxJsResManFPCIndex: FPC Index
jnxJsResManSPUIndex: SPU Index
jnxJsResManResourceUtil is the weighted percentage of utilization
of the Sessions. | |||||||||||||||||||||
| !jnxJsResManServicesMemoryStatus | 1.3.6.1.4.1.2636.3.39.1.12.1.9.3 | ||||||||||||||||||||
notification · current The Resource Manager Services Data Objcache untilization threshold status
trap signifies that the Services Memory load on system has bypassed a
certain percentage
jnxJsResManFPCIndex: FPC Index
jnxJsResManSPUIndex: SPU Index
jnxJsResManResourceUtil is the weighted percentage of utilization
of the Services Memory. | |||||||||||||||||||||
| !jnxJsResManPacketMemoryStatus | 1.3.6.1.4.1.2636.3.39.1.12.1.9.4 | ||||||||||||||||||||
notification · current The Resource Manager Packet Memory untilization threshold status
trap signifies that the Packet Memory load on system has bypassed a
certain percentage
jnxJsResManFPCIndex: FPC Index
jnxJsResManSPUIndex: SPU Index
jnxJsResManResourceUtil is the weighted percentage of utilization
of the Packet Memory. | |||||||||||||||||||||
Traps / Notifications
- jnxJsResManCPUThresholdStatus
1.3.6.1.4.1.2636.3.39.1.12.1.9.1 - jnxJsResManPacketMemoryStatus
1.3.6.1.4.1.2636.3.39.1.12.1.9.4 - jnxJsResManServicesMemoryStatus
1.3.6.1.4.1.2636.3.39.1.12.1.9.3 - jnxJsResManSessionThresholdStatus
1.3.6.1.4.1.2636.3.39.1.12.1.9.2