MIB Browser

JUNIPER-DOM-MIB

Juniper Networks, Inc.
This MIB module defines objects used for Digital Optical
Monitor on  interface of Juniper products.
Organization
Juniper Networks, Inc.
Root OID
1.3.6.1.4.1.2636.3.60.1
Last updated
Objects
52
Source
Show full MIB
snmptranslate -m JUNIPER-DOM-MIB -Tp
snmpwalk -v2c -c <community> -m JUNIPER-DOM-MIB <host> 1.3.6.1.4.1.2636.3.60.1

Imports

IF-MIBifDescr, ifIndex
JUNIPER-SMIjnxDomLaneNotifications, jnxDomMibRoot, jnxDomNotifications
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDateAndTime, DisplayString, PhysAddress, TEXTUAL-CONVENTION

OID tree

NameOIDTypeAccessStatusExample
IjnxDomMib1.3.6.1.4.1.2636.3.60.1
NjnxDomDigitalMonitoring1.3.6.1.4.1.2636.3.60.1.1
TjnxDomCurrentTable1.3.6.1.4.1.2636.3.60.1.1.1NA
RjnxDomCurrentEntry1.3.6.1.4.1.2636.3.60.1.1.1.1NA
CjnxDomCurrentAlarms1.3.6.1.4.1.2636.3.60.1.1.1.1.1JnxDomAlarmIdRO00 00 00
CjnxDomCurrentAlarmDate1.3.6.1.4.1.2636.3.60.1.1.1.1.2DateAndTimeRO00:00:00:00:00:00:00:00:00:00:00
CjnxDomLastAlarms1.3.6.1.4.1.2636.3.60.1.1.1.1.3JnxDomAlarmIdRO00 00 00
CjnxDomCurrentWarnings1.3.6.1.4.1.2636.3.60.1.1.1.1.4JnxDomWarningIdRO00 00 00
CjnxDomCurrentRxLaserPower1.3.6.1.4.1.2636.3.60.1.1.1.1.5Integer32RO0
CjnxDomCurrentTxLaserBiasCurrent1.3.6.1.4.1.2636.3.60.1.1.1.1.6Integer32RO0
CjnxDomCurrentTxLaserOutputPower1.3.6.1.4.1.2636.3.60.1.1.1.1.7Integer32RO0
CjnxDomCurrentModuleTemperature1.3.6.1.4.1.2636.3.60.1.1.1.1.8Integer32RO0
CjnxDomCurrentRxLaserPowerHighAlarmThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.9Integer32RO0
CjnxDomCurrentRxLaserPowerLowAlarmThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.10Integer32RO0
CjnxDomCurrentRxLaserPowerHighWarningThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.11Integer32RO0
CjnxDomCurrentRxLaserPowerLowWarningThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.12Integer32RO0
CjnxDomCurrentTxLaserBiasCurrentHighAlarmThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.13Integer32RO0
CjnxDomCurrentTxLaserBiasCurrentLowAlarmThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.14Integer32RO0
CjnxDomCurrentTxLaserBiasCurrentHighWarningThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.15Integer32RO0
CjnxDomCurrentTxLaserBiasCurrentLowWarningThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.16Integer32RO0
CjnxDomCurrentTxLaserOutputPowerHighAlarmThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.17Integer32RO0
CjnxDomCurrentTxLaserOutputPowerLowAlarmThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.18Integer32RO0
CjnxDomCurrentTxLaserOutputPowerHighWarningThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.19Integer32RO0
CjnxDomCurrentTxLaserOutputPowerLowWarningThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.20Integer32RO0
CjnxDomCurrentModuleTemperatureHighAlarmThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.21Integer32RO0
CjnxDomCurrentModuleTemperatureLowAlarmThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.22Integer32RO0
CjnxDomCurrentModuleTemperatureHighWarningThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.23Integer32RO0
CjnxDomCurrentModuleTemperatureLowWarningThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.24Integer32RO0
CjnxDomCurrentModuleVoltage1.3.6.1.4.1.2636.3.60.1.1.1.1.25Integer32RO0
CjnxDomCurrentModuleVoltageHighAlarmThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.26Integer32RO0
CjnxDomCurrentModuleVoltageLowAlarmThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.27Integer32RO0
CjnxDomCurrentModuleVoltageHighWarningThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.28Integer32RO0
CjnxDomCurrentModuleVoltageLowWarningThreshold1.3.6.1.4.1.2636.3.60.1.1.1.1.29Integer32RO0
CjnxDomCurrentModuleLaneCount1.3.6.1.4.1.2636.3.60.1.1.1.1.30Integer32RO1
NjnxDomDigitalLaneMonitoring1.3.6.1.4.1.2636.3.60.1.2
TjnxDomModuleLaneTable1.3.6.1.4.1.2636.3.60.1.2.1NA
RjnxDomCurrentLaneEntry1.3.6.1.4.1.2636.3.60.1.2.1.1NA
CjnxDomLaneIndex1.3.6.1.4.1.2636.3.60.1.2.1.1.1Integer32 (0..1000)RO0
CjnxDomCurrentLaneAlarms1.3.6.1.4.1.2636.3.60.1.2.1.1.2JnxDomLaneAlarmIdRO00 00 00
CjnxDomCurrentLaneAlarmDate1.3.6.1.4.1.2636.3.60.1.2.1.1.3DateAndTimeRO00:00:00:00:00:00:00:00:00:00:00
CjnxDomLaneLastAlarms1.3.6.1.4.1.2636.3.60.1.2.1.1.4JnxDomLaneAlarmIdRO00 00 00
CjnxDomCurrentLaneWarnings1.3.6.1.4.1.2636.3.60.1.2.1.1.5JnxDomLaneWarningIdRO00 00 00
CjnxDomCurrentLaneRxLaserPower1.3.6.1.4.1.2636.3.60.1.2.1.1.6Integer32RO0
CjnxDomCurrentLaneTxLaserBiasCurrent1.3.6.1.4.1.2636.3.60.1.2.1.1.7Integer32RO0
CjnxDomCurrentLaneTxLaserOutputPower1.3.6.1.4.1.2636.3.60.1.2.1.1.8Integer32RO0
CjnxDomCurrentLaneLaserTemperature1.3.6.1.4.1.2636.3.60.1.2.1.1.9Integer32RO0
NjnxDomNotificationPrefix1.3.6.1.4.1.2636.4.18.0
!jnxDomAlarmSet1.3.6.1.4.1.2636.4.18.0.1
!jnxDomAlarmCleared1.3.6.1.4.1.2636.4.18.0.2
NjnxDomLaneNotificationPrefix1.3.6.1.4.1.2636.4.25.0
!jnxDomLaneAlarmSet1.3.6.1.4.1.2636.4.25.0.1
!jnxDomLaneAlarmCleared1.3.6.1.4.1.2636.4.25.0.2

Textual conventions

JnxDomAlarmId Bits

domLinkDownAlarm(17) domModuleNotReadyAlarm(15) domModulePowerDownAlarm(16) domModuleRemovedAlarm(18) domModuleTemperatureHighAlarm(13) domModuleTemperatureLowAlarm(14) domModuleVoltageHighAlarm(19) domModuleVoltageLowAlarm(20) domRxCDRLossLockAlarm(1) domRxLaserPowerHighAlarm(3) domRxLaserPowerLowAlarm(4) domRxLossSignalAlarm(0) domRxNotReadyAlarm(2) domTxCDRLossLockAlarm(12) domTxDataNotReadyAlarm(9) domTxLaserBiasCurrentHighAlarm(5) domTxLaserBiasCurrentLowAlarm(6) domTxLaserFaultAlarm(11) domTxLaserOutputPowerHighAlarm(7) domTxLaserOutputPowerLowAlarm(8) domTxNotReadyAlarm(10)

Identifies specific DOM alarms that may exist on an
interface.
JnxDomLaneAlarmId Bits

domLaneLaserTemperatureHighAlarm(6) domLaneLaserTemperatureLowAlarm(7) domLaneRxLaserPowerHighAlarm(0) domLaneRxLaserPowerLowAlarm(1) domLaneTxLaserBiasCurrentHighAlarm(2) domLaneTxLaserBiasCurrentLowAlarm(3) domLaneTxLaserOutputPowerHighAlarm(4) domLaneTxLaserOutputPowerLowAlarm(5)

Identifies specific DOM alarms that may exist on
a Lane of a SFF interface
JnxDomLaneWarningId Bits

domLaneLaserTemperatureHighWarning(6) domLaneLaserTemperatureLowWarning(7) domLaneRxLaserPowerHighWarning(0) domLaneRxLaserPowerLowWarning(1) domLaneTxLaserBiasCurrentHighWarning(2) domLaneTxLaserBiasCurrentLowWarning(3) domLaneTxLaserOutputPowerHighWarning(4) domLaneTxLaserOutputPowerLowWarning(5)

Identifies specific DOM warnings that may exist on
a Lane of a SFF interface
JnxDomWarningId Bits

domModuleTemperatureHighWarning(6) domModuleTemperatureLowWarning(7) domModuleVoltageHighWarning(8) domModuleVoltageLowWarning(9) domRxLaserPowerHighWarning(0) domRxLaserPowerLowWarning(1) domTxLaserBiasCurrentHighWarning(2) domTxLaserBiasCurrentLowWarning(3) domTxLaserOutputPowerHighWarning(4) domTxLaserOutputPowerLowWarning(5)

Identifies specific DOM warnings that may exist on an
interface.

Traps / Notifications