IPI-CMM-IPMI-MIB
IP Infusion IncThe Structure of CMM Management Information for the IPI enterprise.
snmptranslate -m IPI-CMM-IPMI-MIB -Tpsnmpwalk -v2c -c <community> -m IPI-CMM-IPMI-MIB <host> 1.3.6.1.4.1.36673.100Imports
| IPI-CMM-CHASSIS-MIB | cmmChassisObject, cmmStackUnitIndex |
|---|---|
| IPI-MODULE-MIB | ipi |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Counter32, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DateAndTime, DisplayString, MacAddress, PhysAddress, RowStatus, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Icmm | 1.3.6.1.4.1.36673.100 | ||||||||||||||||||||
identity The Structure of CMM Management Information for the IPI enterprise. | |||||||||||||||||||||
| NcmmIpmiDeviceObjects | 1.3.6.1.4.1.36673.100.1.5 | ||||||||||||||||||||
| TcmmIpmiDeviceSensorTable | 1.3.6.1.4.1.36673.100.1.5.1 | NA | |||||||||||||||||||
table · not-accessible · current A list of entries containing sensor information for BMC controlled devices. | |||||||||||||||||||||
| RcmmIpmiDeviceSensorEntry | 1.3.6.1.4.1.36673.100.1.5.1.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of entries containing sensor information for BMC controlled devices. | |||||||||||||||||||||
| CcmmIpmiDeviceSensorIndex | 1.3.6.1.4.1.36673.100.1.5.1.1.1 | INTEGER (1..65535) | NA | ||||||||||||||||||
column · INTEGER (1..65535) · not-accessible · current The unique sensor index number. | |||||||||||||||||||||
| CcmmIpmiDeviceSensorName | 1.3.6.1.4.1.36673.100.1.5.1.1.2 | DisplayString | RO | TEMP_MAC | |||||||||||||||||
column · DisplayString · read-only · current The name of IPMI device sensor. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceSensorValue | 1.3.6.1.4.1.36673.100.1.5.1.1.3 | INTEGER | RO | 36000 | |||||||||||||||||
column · INTEGER · read-only · current The value read for IPMI device sensor. Unit: Temperature in degree C, Current in Amps, Power in Watts, Voltage in Volts, Fan-Speed in RPM. '-100002' indicates not applicable
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceSensorUnits | 1.3.6.1.4.1.36673.100.1.5.1.1.4 | DisplayString | RO | degrees C | |||||||||||||||||
column · DisplayString · read-only · current The unit of the value read for IPMI device sensor. For Temperature in degree C, Current in Amps, Power in Watts, Voltage in Volts, Fan-Speed in RPM. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceSensorState | 1.3.6.1.4.1.36673.100.1.5.1.1.5 | DisplayString | RO | ok | |||||||||||||||||
column · DisplayString · read-only · current The operating state of IPMI device sensor. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceSensorLowerNonRecover | 1.3.6.1.4.1.36673.100.1.5.1.1.6 | INTEGER | RO | -100002 | |||||||||||||||||
column · INTEGER · read-only · current The IPMI device sensor lower non recover value. Unit: Temperature in degree C, Current in Amps, Power in Watts, Voltage in Volts, Fan-Speed in RPM. '-100002' indicates not applicable
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceSensorLowerCritical | 1.3.6.1.4.1.36673.100.1.5.1.1.7 | INTEGER | RO | -100002 | |||||||||||||||||
column · INTEGER · read-only · current The IPMI device sensor lower critical value. Unit: Temperature in degree C, Current in Amps, Power in Watts, Voltage in Volts, Fan-Speed in RPM. '-100002' indicates not applicable
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceSensorLowerNonCritical | 1.3.6.1.4.1.36673.100.1.5.1.1.8 | INTEGER | RO | -100002 | |||||||||||||||||
column · INTEGER · read-only · current The IPMI device sensor lower non critical value. Unit: Temperature in degree C, Current in Amps, Power in Watts, Voltage in Volts, Fan-Speed in RPM. -100002' indicates not applicable
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceSensorUpperNonCritical | 1.3.6.1.4.1.36673.100.1.5.1.1.9 | INTEGER | RO | -100002 | |||||||||||||||||
column · INTEGER · read-only · current The IPMI device sensor upper non critical value. Unit: Temperature in degree C, Current in Amps, Power in Watts, Voltage in Volts, Fan-Speed in RPM. '-100002' indicates not applicable
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceSensorUpperCritical | 1.3.6.1.4.1.36673.100.1.5.1.1.10 | INTEGER | RO | 100000 | |||||||||||||||||
column · INTEGER · read-only · current The IPMI device sensor upper critical value. Unit: Temperature in degree C, Current in Amps, Power in Watts, Voltage in Volts, Fan-Speed in RPM. '-100002' indicates not applicable
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceSensorUpperNonRecover | 1.3.6.1.4.1.36673.100.1.5.1.1.11 | INTEGER | RO | 110000 | |||||||||||||||||
column · INTEGER · read-only · current The IPMI device sensor upper non recover value. Unit: Temperature in degree C, Current in Amps, Power in Watts, Voltage in Volts, Fan-Speed in RPM. '-100002' indicates not applicable
Example values from LibreNMS test devices
| |||||||||||||||||||||
| TcmmIpmiDeviceFRUTable | 1.3.6.1.4.1.36673.100.1.5.2 | NA | |||||||||||||||||||
table · not-accessible · current A list of entries containing FRU information for BMC controlled devices. | |||||||||||||||||||||
| RcmmIpmiDeviceFRUEntry | 1.3.6.1.4.1.36673.100.1.5.2.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of entries containing FRU information for BMC controlled devices. | |||||||||||||||||||||
| CcmmIpmiDeviceFRUIndex | 1.3.6.1.4.1.36673.100.1.5.2.1.1 | INTEGER (1..65535) | NA | ||||||||||||||||||
column · INTEGER (1..65535) · not-accessible · current The unique FRU index number. | |||||||||||||||||||||
| CcmmIpmiDeviceBoardMfgDate | 1.3.6.1.4.1.36673.100.1.5.2.1.2 | DateAndTime | RO | 00:15:e8:07:08:06:00:00 | |||||||||||||||||
column · DateAndTime · read-only · current Board manufacturing date. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceBoardMfg | 1.3.6.1.4.1.36673.100.1.5.2.1.3 | DisplayString | RO | UFISPACE | |||||||||||||||||
column · DisplayString · read-only · current Board manufacturer name. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceBoardProduct | 1.3.6.1.4.1.36673.100.1.5.2.1.4 | DisplayString | RO | S9510-28DC-B_MAINBOARD | |||||||||||||||||
column · DisplayString · read-only · current Board product name. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceBoardSerial | 1.3.6.1.4.1.36673.100.1.5.2.1.5 | DisplayString | RO | WRGVE27000N | |||||||||||||||||
column · DisplayString · read-only · current Board Serial number. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceBoardPartNum | 1.3.6.1.4.1.36673.100.1.5.2.1.6 | DisplayString | RO | T99O297T04 | |||||||||||||||||
column · DisplayString · read-only · current Board Part number. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceProductManufacturer | 1.3.6.1.4.1.36673.100.1.5.2.1.7 | DisplayString | RO | UFISPACE | |||||||||||||||||
column · DisplayString · read-only · current Product manufacturer name. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceProductName | 1.3.6.1.4.1.36673.100.1.5.2.1.8 | DisplayString | RO | S9510-28DC-B | |||||||||||||||||
column · DisplayString · read-only · current Product name. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceProductPartNum | 1.3.6.1.4.1.36673.100.1.5.2.1.9 | DisplayString | RO | S9510-28DC-BN0B | |||||||||||||||||
column · DisplayString · read-only · current Product part number. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceProductVersion | 1.3.6.1.4.1.36673.100.1.5.2.1.10 | DisplayString | RO | GA | |||||||||||||||||
column · DisplayString · read-only · current Product version number. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceProductSerial | 1.3.6.1.4.1.36673.100.1.5.2.1.11 | DisplayString | RO | AAAAAAA | |||||||||||||||||
column · DisplayString · read-only · current Product serial number. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceProductAssetTag | 1.3.6.1.4.1.36673.100.1.5.2.1.12 | DisplayString | RO | .................... | |||||||||||||||||
column · DisplayString · read-only · current Product asset tag number. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceProductExtraInfo | 1.3.6.1.4.1.36673.100.1.5.2.1.13 | DisplayString | RO | | |||||||||||||||||
column · DisplayString · read-only · current Product extra information. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceProductExtraInfo2 | 1.3.6.1.4.1.36673.100.1.5.2.1.14 | DisplayString | RO | | |||||||||||||||||
column · DisplayString · read-only · current Product extra information. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcmmIpmiDeviceDescription | 1.3.6.1.4.1.36673.100.1.5.2.1.15 | DisplayString | RO | MAINBOARD_FRU | |||||||||||||||||
column · DisplayString · read-only · current Device Description. Blank indicates unavailable Example values from LibreNMS test devices
| |||||||||||||||||||||
| NcmmIpmiDeviceAlarmObjects | 1.3.6.1.4.1.36673.100.1.6 | ||||||||||||||||||||
| NcmmIpmiDeviceAlarmNotifications | 1.3.6.1.4.1.36673.100.1.6.1 | ||||||||||||||||||||
| !cmmIpmiDeviceLNC | 1.3.6.1.4.1.36673.100.1.6.1.1 | ||||||||||||||||||||
notification · current Set when IPMI device sensor will be below lower non critical threshold for sensor | |||||||||||||||||||||
| !cmmIpmiDeviceLNCRecovery | 1.3.6.1.4.1.36673.100.1.6.1.2 | ||||||||||||||||||||
notification · current Set when IPMI device sensor will be above lower non critical threshold for sensor | |||||||||||||||||||||
| !cmmIpmiDeviceLC | 1.3.6.1.4.1.36673.100.1.6.1.3 | ||||||||||||||||||||
notification · current Set when IPMI device sensor will be below lower critical threshold for sensor | |||||||||||||||||||||
| !cmmIpmiDeviceLCRecovery | 1.3.6.1.4.1.36673.100.1.6.1.4 | ||||||||||||||||||||
notification · current Set when IPMI device sensor will be above lower critical threshold for sensor | |||||||||||||||||||||
| !cmmIpmiDeviceLNR | 1.3.6.1.4.1.36673.100.1.6.1.5 | ||||||||||||||||||||
notification · current Set when IPMI device sensor will be below lower non recovery threshold for sensor | |||||||||||||||||||||
| !cmmIpmiDeviceLNRRecovery | 1.3.6.1.4.1.36673.100.1.6.1.6 | ||||||||||||||||||||
notification · current Set when IPMI device sensor will be above lower non recovery threshold for sensor | |||||||||||||||||||||
| !cmmIpmiDeviceUNC | 1.3.6.1.4.1.36673.100.1.6.1.7 | ||||||||||||||||||||
notification · current Set when IPMI device sensor will be below upper non critical threshold for sensor | |||||||||||||||||||||
| !cmmIpmiDeviceUNCRecovery | 1.3.6.1.4.1.36673.100.1.6.1.8 | ||||||||||||||||||||
notification · current Set when IPMI device sensor will be above upper non critical threshold for sensor | |||||||||||||||||||||
| !cmmIpmiDeviceUC | 1.3.6.1.4.1.36673.100.1.6.1.9 | ||||||||||||||||||||
notification · current Set when IPMI device sensor will be below upper critical threshold for sensor | |||||||||||||||||||||
| !cmmIpmiDeviceUCRecovery | 1.3.6.1.4.1.36673.100.1.6.1.10 | ||||||||||||||||||||
notification · current Set when IPMI device sensor will be above upper critical threshold for sensor | |||||||||||||||||||||
| !cmmIpmiDeviceUNR | 1.3.6.1.4.1.36673.100.1.6.1.11 | ||||||||||||||||||||
notification · current Set when IPMI device sensor will be below upper non recovery threshold for sensor | |||||||||||||||||||||
| !cmmIpmiDeviceUNRRecovery | 1.3.6.1.4.1.36673.100.1.6.1.12 | ||||||||||||||||||||
notification · current Set when IPMI device sensor will be above upper non recovery threshold for sensor | |||||||||||||||||||||
| !cmmIpmiDevicePresence | 1.3.6.1.4.1.36673.100.1.6.1.13 | ||||||||||||||||||||
notification · current Notified when IPMI device inserted/removed | |||||||||||||||||||||
| !cmmIpmiDeviceStatus | 1.3.6.1.4.1.36673.100.1.6.1.14 | ||||||||||||||||||||
Traps / Notifications
- cmmIpmiDeviceLC
1.3.6.1.4.1.36673.100.1.6.1.3 - cmmIpmiDeviceLCRecovery
1.3.6.1.4.1.36673.100.1.6.1.4 - cmmIpmiDeviceLNC
1.3.6.1.4.1.36673.100.1.6.1.1 - cmmIpmiDeviceLNCRecovery
1.3.6.1.4.1.36673.100.1.6.1.2 - cmmIpmiDeviceLNR
1.3.6.1.4.1.36673.100.1.6.1.5 - cmmIpmiDeviceLNRRecovery
1.3.6.1.4.1.36673.100.1.6.1.6 - cmmIpmiDevicePresence
1.3.6.1.4.1.36673.100.1.6.1.13 - cmmIpmiDeviceStatus
1.3.6.1.4.1.36673.100.1.6.1.14 - cmmIpmiDeviceUC
1.3.6.1.4.1.36673.100.1.6.1.9 - cmmIpmiDeviceUCRecovery
1.3.6.1.4.1.36673.100.1.6.1.10 - cmmIpmiDeviceUNC
1.3.6.1.4.1.36673.100.1.6.1.7 - cmmIpmiDeviceUNCRecovery
1.3.6.1.4.1.36673.100.1.6.1.8 - cmmIpmiDeviceUNR
1.3.6.1.4.1.36673.100.1.6.1.11 - cmmIpmiDeviceUNRRecovery
1.3.6.1.4.1.36673.100.1.6.1.12