MIB Browser
The common equipment configuration MIB.

- General

- Subrack status

- Board configuration and status

- Power supply status

- Fan status

- Slot
Organization
Infinera Corporation
Root OID
1.3.6.1.4.1.8708.1.1.12
Last updated
Objects
290
Source
Show full MIB
snmptranslate -m LUM-EQUIPMENT-MIB -Tp
snmpwalk -v2c -c <community> -m LUM-EQUIPMENT-MIB <host> 1.3.6.1.4.1.8708.1.1.12

Imports

LUM-ALARM-MIBAlarmPerceivedSeverity
LUM-REGlumEquipmentMIB, lumModules
LUM-TCAdminStatus, BoardOrInterfaceAdminStatus, BoardOrInterfaceOperStatus, CommandString, FaultStatus, MgmtNameString, ObjectProperty, SlotNumber, SubrackNumber, TruthValueWithNA
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDateAndTime, DisplayString, PhysAddress, RowStatus, TEXTUAL-CONVENTION, TestAndIncr

OID tree

NameOIDTypeAccessStatusExample
IlumEquipmentMIBModule1.3.6.1.4.1.8708.1.1.12
NlumEquipmentConfs1.3.6.1.4.1.8708.2.11.1
NlumEquipmentGroups1.3.6.1.4.1.8708.2.11.1.1
GequipmentGeneralGroup1.3.6.1.4.1.8708.2.11.1.1.1
GequipmentSubrackGroup1.3.6.1.4.1.8708.2.11.1.1.2deprecated
GequipmentBoardGroup1.3.6.1.4.1.8708.2.11.1.1.3deprecated
GequipmentPowerGroup1.3.6.1.4.1.8708.2.11.1.1.4deprecated
GequipmentFanGroup1.3.6.1.4.1.8708.2.11.1.1.5deprecated
GequipmentGeneralGroupV21.3.6.1.4.1.8708.2.11.1.1.6deprecated
GequipmentNotificationGroup1.3.6.1.4.1.8708.2.11.1.1.7deprecated
GequipmentSubrackGroupV21.3.6.1.4.1.8708.2.11.1.1.8deprecated
GequipmentSubrackGroupV31.3.6.1.4.1.8708.2.11.1.1.9deprecated
GequipmentBoardGroupV21.3.6.1.4.1.8708.2.11.1.1.10deprecated
GequipmentNodeGroup1.3.6.1.4.1.8708.2.11.1.1.11deprecated
GequipmentGeneralGroupV31.3.6.1.4.1.8708.2.11.1.1.12deprecated
GequipmentNodeGroupV21.3.6.1.4.1.8708.2.11.1.1.13deprecated
GequipmentNodeGroupV31.3.6.1.4.1.8708.2.11.1.1.14deprecated
GequipmentSubrackGroupV41.3.6.1.4.1.8708.2.11.1.1.15deprecated
GequipmentBoardGroupV31.3.6.1.4.1.8708.2.11.1.1.16deprecated
GequipmentNotificationGroupV21.3.6.1.4.1.8708.2.11.1.1.17deprecated
GequipmentSubrackGroupV51.3.6.1.4.1.8708.2.11.1.1.18deprecated
GequipmentFanGroupV21.3.6.1.4.1.8708.2.11.1.1.19deprecated
GequipmentGeneralGroupV41.3.6.1.4.1.8708.2.11.1.1.20deprecated
GequipmentSubrackGroupV61.3.6.1.4.1.8708.2.11.1.1.21deprecated
GequipmentBoardGroupV41.3.6.1.4.1.8708.2.11.1.1.22deprecated
GequipmentPowerGroupV21.3.6.1.4.1.8708.2.11.1.1.23deprecated
GequipmentFanGroupV31.3.6.1.4.1.8708.2.11.1.1.24deprecated
GequipmentNodeGroupV41.3.6.1.4.1.8708.2.11.1.1.25deprecated
GequipmentBoardGroupV51.3.6.1.4.1.8708.2.11.1.1.26deprecated
GequipmentBoardGroupV61.3.6.1.4.1.8708.2.11.1.1.27deprecated
GequipmentBoardGroupV71.3.6.1.4.1.8708.2.11.1.1.28deprecated
GequipmentNodeGroupV81.3.6.1.4.1.8708.2.11.1.1.29deprecated
GequipmentBoardGroupV81.3.6.1.4.1.8708.2.11.1.1.30deprecated
GequipmentNodeGroupV91.3.6.1.4.1.8708.2.11.1.1.31deprecated
GequipmentResourceGroup1.3.6.1.4.1.8708.2.11.1.1.32
GequipmentSubrackGroupV71.3.6.1.4.1.8708.2.11.1.1.33deprecated
GequipmentSubrackGroupV81.3.6.1.4.1.8708.2.11.1.1.34deprecated
GequipmentBoardGroupV91.3.6.1.4.1.8708.2.11.1.1.35deprecated
GequipmentNotificationGroupV31.3.6.1.4.1.8708.2.11.1.1.36
GequipmentBoardGroupV101.3.6.1.4.1.8708.2.11.1.1.37deprecated
GequipmentNodeGroupV101.3.6.1.4.1.8708.2.11.1.1.38deprecated
GequipmentBoardGroupV111.3.6.1.4.1.8708.2.11.1.1.40deprecated
GequipmentFanGroupV41.3.6.1.4.1.8708.2.11.1.1.41deprecated
GequipmentSlotGroup1.3.6.1.4.1.8708.2.11.1.1.42deprecated
GequipmentBoardGroupV121.3.6.1.4.1.8708.2.11.1.1.43deprecated
GequipmentNodeGroupV111.3.6.1.4.1.8708.2.11.1.1.44
GequipmentBoardGroupV131.3.6.1.4.1.8708.2.11.1.1.45deprecated
GequipmentPowerGroupV31.3.6.1.4.1.8708.2.11.1.1.46deprecated
GequipmentBoardGroupV141.3.6.1.4.1.8708.2.11.1.1.47
GequipmentSlotGroupV21.3.6.1.4.1.8708.2.11.1.1.48
GequipmentSubrackGroupV91.3.6.1.4.1.8708.2.11.1.1.49deprecated
GequipmentPowerGroupV41.3.6.1.4.1.8708.2.11.1.1.50deprecated
GequipmentFanGroupV51.3.6.1.4.1.8708.2.11.1.1.51
GequipmentGeneralGroupV51.3.6.1.4.1.8708.2.11.1.1.52deprecated
GequipmentSubrackGroupV101.3.6.1.4.1.8708.2.11.1.1.53
GequipmentGeneralGroupV61.3.6.1.4.1.8708.2.11.1.1.54
GequipmentOpticalModuleGroup1.3.6.1.4.1.8708.2.11.1.1.55
GequipmentPowerGroupV51.3.6.1.4.1.8708.2.11.1.1.56
NlumEquipmentCompl1.3.6.1.4.1.8708.2.11.1.2
MlumEquipmentBasicComplV11.3.6.1.4.1.8708.2.11.1.2.1deprecated
MlumEquipmentBasicComplV21.3.6.1.4.1.8708.2.11.1.2.2deprecated
MlumEquipmentBasicComplV31.3.6.1.4.1.8708.2.11.1.2.3deprecated
MlumEquipmentBasicComplV41.3.6.1.4.1.8708.2.11.1.2.4deprecated
MlumEquipmentBasicComplV51.3.6.1.4.1.8708.2.11.1.2.5deprecated
MlumEquipmentBasicComplV61.3.6.1.4.1.8708.2.11.1.2.6deprecated
MlumEquipmentBasicComplV71.3.6.1.4.1.8708.2.11.1.2.7deprecated
MlumEquipmentBasicComplV81.3.6.1.4.1.8708.2.11.1.2.8deprecated
MlumEquipmentBasicComplV91.3.6.1.4.1.8708.2.11.1.2.9deprecated
MlumEquipmentBasicComplV101.3.6.1.4.1.8708.2.11.1.2.10deprecated
MlumEquipmentBasicComplV111.3.6.1.4.1.8708.2.11.1.2.11deprecated
MlumEquipmentBasicComplV121.3.6.1.4.1.8708.2.11.1.2.12deprecated
MlumEquipmentBasicComplV131.3.6.1.4.1.8708.2.11.1.2.13deprecated
MlumEquipmentBasicComplV141.3.6.1.4.1.8708.2.11.1.2.14deprecated
MlumEquipmentBasicComplV151.3.6.1.4.1.8708.2.11.1.2.15deprecated
MlumEquipmentBasicComplV161.3.6.1.4.1.8708.2.11.1.2.16deprecated
MlumEquipmentBasicComplV171.3.6.1.4.1.8708.2.11.1.2.17deprecated
MlumEquipmentBasicComplV181.3.6.1.4.1.8708.2.11.1.2.18deprecated
MlumEquipmentBasicComplV191.3.6.1.4.1.8708.2.11.1.2.19deprecated
MlumEquipmentBasicComplV201.3.6.1.4.1.8708.2.11.1.2.20deprecated
MlumEquipmentBasicComplV211.3.6.1.4.1.8708.2.11.1.2.21deprecated
MlumEquipmentBasicComplV221.3.6.1.4.1.8708.2.11.1.2.22deprecated
MlumEquipmentBasicComplV231.3.6.1.4.1.8708.2.11.1.2.23deprecated
MlumEquipmentBasicComplV241.3.6.1.4.1.8708.2.11.1.2.24deprecated
MlumEquipmentBasicComplV251.3.6.1.4.1.8708.2.11.1.2.25deprecated
MlumEquipmentBasicComplV261.3.6.1.4.1.8708.2.11.1.2.26deprecated
MlumEquipmentBasicComplV271.3.6.1.4.1.8708.2.11.1.2.27deprecated
MlumEquipmentBasicComplV281.3.6.1.4.1.8708.2.11.1.2.28deprecated
MlumEquipmentBasicComplV291.3.6.1.4.1.8708.2.11.1.2.29deprecated
MlumEquipmentBasicComplV301.3.6.1.4.1.8708.2.11.1.2.30deprecated
MlumEquipmentBasicComplV311.3.6.1.4.1.8708.2.11.1.2.31deprecated
MlumEquipmentBasicComplV321.3.6.1.4.1.8708.2.11.1.2.32deprecated
MlumEquipmentBasicComplV331.3.6.1.4.1.8708.2.11.1.2.33deprecated
MlumEquipmentBasicComplV341.3.6.1.4.1.8708.2.11.1.2.34deprecated
MlumEquipmentBasicComplV351.3.6.1.4.1.8708.2.11.1.2.35deprecated
MlumEquipmentBasicComplV361.3.6.1.4.1.8708.2.11.1.2.36deprecated
MlumEquipmentBasicComplV371.3.6.1.4.1.8708.2.11.1.2.37
NlumEquipmentMinimalGroups1.3.6.1.4.1.8708.2.11.1.3
GequipmentGeneralMinimalGroupV11.3.6.1.4.1.8708.2.11.1.3.1
GequipmentBoardMinimalGroupV11.3.6.1.4.1.8708.2.11.1.3.2deprecated
GequipmentBoardMinimalGroupV21.3.6.1.4.1.8708.2.11.1.3.3
NlumEquipmentMinimalCompl1.3.6.1.4.1.8708.2.11.1.4
MlumEquipmentMinimalComplV11.3.6.1.4.1.8708.2.11.1.4.1deprecated
MlumEquipmentMinimalComplV21.3.6.1.4.1.8708.2.11.1.4.2deprecated
MlumEquipmentMinimalComplV31.3.6.1.4.1.8708.2.11.1.4.3deprecated
MlumEquipmentMinimalComplV41.3.6.1.4.1.8708.2.11.1.4.4
MlumEquipmentMinimalComplV51.3.6.1.4.1.8708.2.11.1.4.5deprecated
MlumEquipmentMinimalComplV61.3.6.1.4.1.8708.2.11.1.4.6
NlumEquipmentMIBObjects1.3.6.1.4.1.8708.2.11.2
NequipmentGeneral1.3.6.1.4.1.8708.2.11.2.1
SequipmentGeneralTestAndIncr1.3.6.1.4.1.8708.2.11.2.1.1TestAndIncrRW
SequipmentGeneralMibSpecVersion1.3.6.1.4.1.8708.2.11.2.1.2DisplayStringRW
SequipmentGeneralMibImplVersion1.3.6.1.4.1.8708.2.11.2.1.3DisplayStringRW
SequipmentGeneralLastChangeTime1.3.6.1.4.1.8708.2.11.2.1.4DateAndTimeRO
SequipmentGeneralStateLastChangeTime1.3.6.1.4.1.8708.2.11.2.1.5DateAndTimeRO
SequipmentGeneralEquipmentSubrackTableSize1.3.6.1.4.1.8708.2.11.2.1.6Unsigned32RO
SequipmentGeneralEquipmentBoardTableSize1.3.6.1.4.1.8708.2.11.2.1.7Unsigned32RO
SequipmentGeneralEquipmentPowerTableSize1.3.6.1.4.1.8708.2.11.2.1.8Unsigned32RO
SequipmentGeneralEquipmentFanTableSize1.3.6.1.4.1.8708.2.11.2.1.9Unsigned32RO
SequipmentGeneralEquipmentSlotTableSize1.3.6.1.4.1.8708.2.11.2.1.10Unsigned32RO
SequipmentGeneralEquipmentOpticalModuleTableSize1.3.6.1.4.1.8708.2.11.2.1.11Unsigned32RO
NequipmentSubrackList1.3.6.1.4.1.8708.2.11.2.2
TequipmentSubrackTable1.3.6.1.4.1.8708.2.11.2.2.1NA
RequipmentSubrackEntry1.3.6.1.4.1.8708.2.11.2.2.1.1NA
CequipmentSubrackIndex1.3.6.1.4.1.8708.2.11.2.2.1.1.1Unsigned32 (1..2147483647)RO1
CequipmentSubrackName1.3.6.1.4.1.8708.2.11.2.2.1.1.2MgmtNameStringROtm3000ii:1
CequipmentSubrackSubrack1.3.6.1.4.1.8708.2.11.2.2.1.1.3SubrackNumberRC1
CequipmentSubrackDescr1.3.6.1.4.1.8708.2.11.2.2.1.1.4DisplayStringRW
CequipmentSubrackInvPhysIndexOrZero1.3.6.1.4.1.8708.2.11.2.2.1.1.5Unsigned32 (0..2147483647)RO100000000
CequipmentSubrackAllFanUnitsFailed1.3.6.1.4.1.8708.2.11.2.2.1.1.6FaultStatusRO1
CequipmentSubrackRowStatus1.3.6.1.4.1.8708.2.11.2.2.1.1.7RowStatusRC1
CequipmentSubrackExpectedType1.3.6.1.4.1.8708.2.11.2.2.1.1.8EquipmentSubrackTypeRW13
CequipmentSubrackActualType1.3.6.1.4.1.8708.2.11.2.2.1.1.9EquipmentSubrackTypeRO13
CequipmentSubrackUnexpectedType1.3.6.1.4.1.8708.2.11.2.2.1.1.10FaultStatusRO1
CequipmentSubrackTemp1.3.6.1.4.1.8708.2.11.2.2.1.1.11Integer32 (-1000..1000)RO372
CequipmentSubrackTempHighExceeded1.3.6.1.4.1.8708.2.11.2.2.1.1.12FaultStatusRO1
CequipmentSubrackTempThreshold1.3.6.1.4.1.8708.2.11.2.2.1.1.13Integer32 (-100..800)RW550
CequipmentSubrackDataChanged1.3.6.1.4.1.8708.2.11.2.2.1.1.14FaultStatusRO1
CequipmentSubrackSystemModeSet1.3.6.1.4.1.8708.2.11.2.2.1.1.15FaultStatusRO1
CequipmentSubrackEffectiveSystemMode1.3.6.1.4.1.8708.2.11.2.2.1.1.16Unsigned32 (0..2147483647)RO0
CequipmentSubrackCurrentSystemMode1.3.6.1.4.1.8708.2.11.2.2.1.1.17Unsigned32 (0..2147483647)RO0
CequipmentSubrackAdminStatus1.3.6.1.4.1.8708.2.11.2.2.1.1.18INTEGERRWup(2)
CequipmentSubrackOperStatus1.3.6.1.4.1.8708.2.11.2.2.1.1.19INTEGERROup(3)
CequipmentSubrackObjectProperty1.3.6.1.4.1.8708.2.11.2.2.1.1.20ObjectPropertyRO0
CequipmentSubrackShelfLength1.3.6.1.4.1.8708.2.11.2.2.1.1.21Unsigned32 (0..32)RW0
CequipmentSubrackLANModuleMissing1.3.6.1.4.1.8708.2.11.2.2.1.1.22FaultStatusRO1
CequipmentSubrackExpectedFirstPbSlot1.3.6.1.4.1.8708.2.11.2.2.1.1.23FirstPbSlotRW0
CequipmentSubrackActualFirstPbSlot1.3.6.1.4.1.8708.2.11.2.2.1.1.24FirstPbSlotRO4
CequipmentSubrackFirstPbSlotMismatch1.3.6.1.4.1.8708.2.11.2.2.1.1.25FaultStatusRO1
CequipmentSubrackAid1.3.6.1.4.1.8708.2.11.2.2.1.1.26DisplayStringROSUB-1
CequipmentSubrackPhysicalLocation1.3.6.1.4.1.8708.2.11.2.2.1.1.27DisplayStringROSUB-1
CequipmentSubrackChangeExpectedType1.3.6.1.4.1.8708.2.11.2.2.1.1.28CommandStringRO
NequipmentBoardList1.3.6.1.4.1.8708.2.11.2.3
TequipmentBoardTable1.3.6.1.4.1.8708.2.11.2.3.1NA
RequipmentBoardEntry1.3.6.1.4.1.8708.2.11.2.3.1.1NA
CequipmentBoardIndex1.3.6.1.4.1.8708.2.11.2.3.1.1.1Unsigned32 (1..2147483647)RO10101
CequipmentBoardName1.3.6.1.4.1.8708.2.11.2.3.1.1.2MgmtNameStringROcusfpii:1:1
CequipmentBoardExpectedType1.3.6.1.4.1.8708.2.11.2.3.1.1.3EquipmentBoardTypeRC158
CequipmentBoardActualType1.3.6.1.4.1.8708.2.11.2.3.1.1.4EquipmentBoardTypeRO158
CequipmentBoardDescr1.3.6.1.4.1.8708.2.11.2.3.1.1.5DisplayStringRW
CequipmentBoardSubrack1.3.6.1.4.1.8708.2.11.2.3.1.1.6SubrackNumberRC1
CequipmentBoardSlot1.3.6.1.4.1.8708.2.11.2.3.1.1.7SlotNumberRC1
CequipmentBoardTemp1.3.6.1.4.1.8708.2.11.2.3.1.1.8Integer32 (-1000..1000)RO357
CequipmentBoardInvPhysIndexOrZero1.3.6.1.4.1.8708.2.11.2.3.1.1.9Unsigned32 (0..2147483647)RO101000000
CequipmentBoardLedTest1.3.6.1.4.1.8708.2.11.2.3.1.1.10INTEGERRWoff(1)
CequipmentBoardAdminStatus1.3.6.1.4.1.8708.2.11.2.3.1.1.11BoardOrInterfaceAdminStatusRW3
CequipmentBoardOperStatus1.3.6.1.4.1.8708.2.11.2.3.1.1.12BoardOrInterfaceOperStatusRO3
CequipmentBoardLastChangeTime1.3.6.1.4.1.8708.2.11.2.3.1.1.13DateAndTimeRO07:e4:02:19:00:39:33:00:2b:01:00
CequipmentBoardRowStatus1.3.6.1.4.1.8708.2.11.2.3.1.1.14RowStatusRC1
CequipmentBoardMissing1.3.6.1.4.1.8708.2.11.2.3.1.1.15FaultStatusRO1
CequipmentBoardUnexpectedType1.3.6.1.4.1.8708.2.11.2.3.1.1.16FaultStatusRO1
CequipmentBoardTempHighExceeded1.3.6.1.4.1.8708.2.11.2.3.1.1.17FaultStatusRO1
CequipmentBoardCommunicationFailure1.3.6.1.4.1.8708.2.11.2.3.1.1.18FaultStatusRO1
CequipmentBoardInterworkFailed1.3.6.1.4.1.8708.2.11.2.3.1.1.19FaultStatusRO1
CequipmentBoardSecondaryPowerFailed1.3.6.1.4.1.8708.2.11.2.3.1.1.20FaultStatusRO1
CequipmentBoardVitalDataMissing1.3.6.1.4.1.8708.2.11.2.3.1.1.21FaultStatusRO1
CequipmentBoardNonVitalDataMissing1.3.6.1.4.1.8708.2.11.2.3.1.1.22FaultStatusRO1
CequipmentBoardUnderMaintenance1.3.6.1.4.1.8708.2.11.2.3.1.1.23FaultStatusRO1
CequipmentBoardTempThreshold1.3.6.1.4.1.8708.2.11.2.3.1.1.24Integer32 (0..800)RW700
CequipmentBoardSwVersionMismatch1.3.6.1.4.1.8708.2.11.2.3.1.1.25FaultStatusRO1
CequipmentBoardObjectProperty1.3.6.1.4.1.8708.2.11.2.3.1.1.26ObjectPropertyRO568328305
CequipmentBoardTempLow1.3.6.1.4.1.8708.2.11.2.3.1.1.27FaultStatusRO1
CequipmentBoardTempVeryHigh1.3.6.1.4.1.8708.2.11.2.3.1.1.28FaultStatusRO1
CequipmentBoardReconfigure1.3.6.1.4.1.8708.2.11.2.3.1.1.29CommandStringRO
CequipmentBoardLedStatus1.3.6.1.4.1.8708.2.11.2.3.1.1.30INTEGERROclear(1)
CequipmentBoardModuleInfo1.3.6.1.4.1.8708.2.11.2.3.1.1.31DisplayStringRO
CequipmentBoardNewSwActivatedButNotRestarted1.3.6.1.4.1.8708.2.11.2.3.1.1.32FaultStatusRO1
CequipmentBoardLowTemperature1.3.6.1.4.1.8708.2.11.2.3.1.1.33FaultStatusRO1
CequipmentBoardTempLowThreshold1.3.6.1.4.1.8708.2.11.2.3.1.1.34Integer32 (-400..400)RO30
CequipmentBoardAdditionalInfo1.3.6.1.4.1.8708.2.11.2.3.1.1.35DisplayStringRO
CequipmentBoardBootError1.3.6.1.4.1.8708.2.11.2.3.1.1.36FaultStatusRO1
CequipmentBoardHardwareError1.3.6.1.4.1.8708.2.11.2.3.1.1.37FaultStatusRO1
CequipmentBoardLowDiskSpace1.3.6.1.4.1.8708.2.11.2.3.1.1.38FaultStatusRO1
CequipmentBoardClockDrift1.3.6.1.4.1.8708.2.11.2.3.1.1.39FaultStatusRO1
CequipmentBoardPostponeFwUpgrade1.3.6.1.4.1.8708.2.11.2.3.1.1.40INTEGERRWdisabled(1)
CequipmentBoardActivatePendingFwCommand1.3.6.1.4.1.8708.2.11.2.3.1.1.41CommandStringRO
CequipmentBoardFwActivationPending1.3.6.1.4.1.8708.2.11.2.3.1.1.42FaultStatusRO1
CequipmentBoardFeatureNotSupported1.3.6.1.4.1.8708.2.11.2.3.1.1.43FaultStatusRO1
CequipmentBoardFwReloadNeeded1.3.6.1.4.1.8708.2.11.2.3.1.1.44FaultStatusRO1
CequipmentBoardFwContextUnknown1.3.6.1.4.1.8708.2.11.2.3.1.1.45FaultStatusRO1
CequipmentBoardBoardVariant1.3.6.1.4.1.8708.2.11.2.3.1.1.46INTEGERRWnotApplicable(2147483647)
CequipmentBoardCabinetConnectivity1.3.6.1.4.1.8708.2.11.2.3.1.1.47INTEGERRWdisabled(1)
CequipmentBoardCabinetConnectionFailure1.3.6.1.4.1.8708.2.11.2.3.1.1.48FaultStatusRO1
CequipmentBoardOperationalVariant1.3.6.1.4.1.8708.2.11.2.3.1.1.49INTEGERRCnormal(1)
CequipmentBoardAid1.3.6.1.4.1.8708.2.11.2.3.1.1.50DisplayStringROBRD-1-1
CequipmentBoardPhysicalLocation1.3.6.1.4.1.8708.2.11.2.3.1.1.51DisplayStringROBRD-1-1
NequipmentPowerList1.3.6.1.4.1.8708.2.11.2.4
TequipmentPowerTable1.3.6.1.4.1.8708.2.11.2.4.1NA
RequipmentPowerEntry1.3.6.1.4.1.8708.2.11.2.4.1.1NA
CequipmentPowerIndex1.3.6.1.4.1.8708.2.11.2.4.1.1.1Unsigned32 (1..2147483647)RO1011
CequipmentPowerName1.3.6.1.4.1.8708.2.11.2.4.1.1.2DisplayString (SIZE (0..255))ROpow:1:1
CequipmentPowerSubrack1.3.6.1.4.1.8708.2.11.2.4.1.1.3SubrackNumberRO1
CequipmentPowerSlot1.3.6.1.4.1.8708.2.11.2.4.1.1.4Unsigned32 (1..2)RO1
CequipmentPowerType1.3.6.1.4.1.8708.2.11.2.4.1.1.5INTEGERROdc(2)
CequipmentPowerInvPhysIndexOrZero1.3.6.1.4.1.8708.2.11.2.4.1.1.9Unsigned32 (0..2147483647)RO151000000
CequipmentPowerAdminStatus1.3.6.1.4.1.8708.2.11.2.4.1.1.10INTEGERRWup(2)
CequipmentPowerOperStatus1.3.6.1.4.1.8708.2.11.2.4.1.1.11INTEGERROup(3)
CequipmentPowerRowStatus1.3.6.1.4.1.8708.2.11.2.4.1.1.12RowStatusRW
CequipmentPowerACPowerFailed1.3.6.1.4.1.8708.2.11.2.4.1.1.13FaultStatusROobsolete
CequipmentPowerDCPowerFailed1.3.6.1.4.1.8708.2.11.2.4.1.1.14FaultStatusROobsolete
CequipmentPowerTemperatureHigh1.3.6.1.4.1.8708.2.11.2.4.1.1.15FaultStatusRO1
CequipmentPowerModuleMissing1.3.6.1.4.1.8708.2.11.2.4.1.1.16FaultStatusRO1
CequipmentPowerObjectProperty1.3.6.1.4.1.8708.2.11.2.4.1.1.17ObjectPropertyRO0
CequipmentPowerDCPowerFailedSeverity1.3.6.1.4.1.8708.2.11.2.4.1.1.18AlarmPerceivedSeverityRW4
CequipmentPowerAid1.3.6.1.4.1.8708.2.11.2.4.1.1.19DisplayStringROPOW-1-1
CequipmentPowerPhysicalLocation1.3.6.1.4.1.8708.2.11.2.4.1.1.20DisplayStringROPOW-1-1
CequipmentPowerPowerFailed1.3.6.1.4.1.8708.2.11.2.4.1.1.21FaultStatusRO1
NequipmentFanList1.3.6.1.4.1.8708.2.11.2.5
TequipmentFanTable1.3.6.1.4.1.8708.2.11.2.5.1NA
RequipmentFanEntry1.3.6.1.4.1.8708.2.11.2.5.1.1NA
CequipmentFanIndex1.3.6.1.4.1.8708.2.11.2.5.1.1.1Unsigned32 (1..2147483647)RO1011
CequipmentFanName1.3.6.1.4.1.8708.2.11.2.5.1.1.2DisplayString (SIZE (0..255))ROfan:1:1
CequipmentFanSubrack1.3.6.1.4.1.8708.2.11.2.5.1.1.3SubrackNumberRO1
CequipmentFanSlot1.3.6.1.4.1.8708.2.11.2.5.1.1.4Unsigned32 (1..3)RO1
CequipmentFanInvPhysIndexOrZero1.3.6.1.4.1.8708.2.11.2.5.1.1.5Unsigned32 (0..2147483647)RO153000000
CequipmentFanAdminStatus1.3.6.1.4.1.8708.2.11.2.5.1.1.6INTEGERRWup(2)
CequipmentFanOperStatus1.3.6.1.4.1.8708.2.11.2.5.1.1.7INTEGERROup(3)
CequipmentFanRowStatus1.3.6.1.4.1.8708.2.11.2.5.1.1.8RowStatusRW
CequipmentFanUnitFailed1.3.6.1.4.1.8708.2.11.2.5.1.1.9FaultStatusRO1
CequipmentFanMainUnitFailed1.3.6.1.4.1.8708.2.11.2.5.1.1.10FaultStatusRO1
CequipmentFanObjectProperty1.3.6.1.4.1.8708.2.11.2.5.1.1.11ObjectPropertyRO0
CequipmentFanFanFault1.3.6.1.4.1.8708.2.11.2.5.1.1.12FaultStatusRO1
CequipmentFanAid1.3.6.1.4.1.8708.2.11.2.5.1.1.13DisplayStringROFAN-1-1
CequipmentFanPhysicalLocation1.3.6.1.4.1.8708.2.11.2.5.1.1.14DisplayStringROFAN-1-1
NlumentisEquipmentNotifications1.3.6.1.4.1.8708.2.11.2.6
NequipmentNotifyPrefix1.3.6.1.4.1.8708.2.11.2.6.0
!equipmentBoardRowStatusActive1.3.6.1.4.1.8708.2.11.2.6.0.1
!equipmentBoardRowStatusDestroy1.3.6.1.4.1.8708.2.11.2.6.0.2deprecated
!equipmentBoardRowStatusInserted1.3.6.1.4.1.8708.2.11.2.6.0.3
!equipmentBoardRowStatusRemoved1.3.6.1.4.1.8708.2.11.2.6.0.4
!equipmentBoardRowStatusDeleted1.3.6.1.4.1.8708.2.11.2.6.0.5
NequipmentNode1.3.6.1.4.1.8708.2.11.2.7
SequipmentNodeLedTest1.3.6.1.4.1.8708.2.11.2.7.1INTEGERRW
SequipmentNodeIcnRedundancyMode1.3.6.1.4.1.8708.2.11.2.7.2INTEGERRW
SequipmentNodeMemoryProfile1.3.6.1.4.1.8708.2.11.2.7.3INTEGERRO
SequipmentAllowDummyPassiveSlots1.3.6.1.4.1.8708.2.11.2.7.4INTEGERRW
SequipmentNodeManagementVlan1.3.6.1.4.1.8708.2.11.2.7.5INTEGERRW
SequipmentNodeMgmtVlanPrivacy1.3.6.1.4.1.8708.2.11.2.7.6INTEGERRW
SequipmentNodeDcnRedundancyMode1.3.6.1.4.1.8708.2.11.2.7.7INTEGERRW
SequipmentNodeProxyArp1.3.6.1.4.1.8708.2.11.2.7.8INTEGERRW
NequipmentResource1.3.6.1.4.1.8708.2.11.2.8
SequipmentResourceNumberOfBoards1.3.6.1.4.1.8708.2.11.2.8.1Unsigned32RO
SequipmentResourceMaxNumberOfBoards1.3.6.1.4.1.8708.2.11.2.8.2Unsigned32RO
SequipmentResourceNumberOfActiveBoards1.3.6.1.4.1.8708.2.11.2.8.3Unsigned32RO
SequipmentResourceMaxNumberOfActiveBoards1.3.6.1.4.1.8708.2.11.2.8.4Unsigned32RO
NequipmentSlot1.3.6.1.4.1.8708.2.11.2.9
TequipmentSlotTable1.3.6.1.4.1.8708.2.11.2.9.1NA
RequipmentSlotEntry1.3.6.1.4.1.8708.2.11.2.9.1.1NA
CequipmentSlotIndex1.3.6.1.4.1.8708.2.11.2.9.1.1.1Unsigned32 (1..2147483647)RO
CequipmentSlotName1.3.6.1.4.1.8708.2.11.2.9.1.1.2MgmtNameStringRO
CequipmentSlotSubrack1.3.6.1.4.1.8708.2.11.2.9.1.1.3SubrackNumberRO
CequipmentSlotSlot1.3.6.1.4.1.8708.2.11.2.9.1.1.4SlotNumberRO
CequipmentSlotAdminStatus1.3.6.1.4.1.8708.2.11.2.9.1.1.5AdminStatusRW
CequipmentSlotUsageState1.3.6.1.4.1.8708.2.11.2.9.1.1.6INTEGERRO
CequipmentSlotEmptySlot1.3.6.1.4.1.8708.2.11.2.9.1.1.7FaultStatusRO
CequipmentSlotEquipped1.3.6.1.4.1.8708.2.11.2.9.1.1.8TruthValueWithNARO
CequipmentSlotAid1.3.6.1.4.1.8708.2.11.2.9.1.1.9DisplayString (SIZE (0..255))RO
CequipmentSlotPhysicalLocation1.3.6.1.4.1.8708.2.11.2.9.1.1.10DisplayString (SIZE (0..255))RO
NequipmentOpticalModuleList1.3.6.1.4.1.8708.2.11.2.10
TequipmentOpticalModuleTable1.3.6.1.4.1.8708.2.11.2.10.1NA
RequipmentOpticalModuleEntry1.3.6.1.4.1.8708.2.11.2.10.1.1NA
CequipmentOpticalModuleIndex1.3.6.1.4.1.8708.2.11.2.10.1.1.1Unsigned32 (1..2147483647)RO
CequipmentOpticalModuleHostBoardType1.3.6.1.4.1.8708.2.11.2.10.1.1.2EquipmentBoardTypeRO
CequipmentOpticalModuleType1.3.6.1.4.1.8708.2.11.2.10.1.1.3MgmtNameStringRO
CequipmentOpticalModuleName1.3.6.1.4.1.8708.2.11.2.10.1.1.4MgmtNameStringRO
CequipmentOpticalModuleSubrack1.3.6.1.4.1.8708.2.11.2.10.1.1.5SubrackNumberRO
CequipmentOpticalModuleSlot1.3.6.1.4.1.8708.2.11.2.10.1.1.6SlotNumberRO
CequipmentOpticalModuleFirmwareVersion1.3.6.1.4.1.8708.2.11.2.10.1.1.7DisplayStringRO
CequipmentOpticalModuleSerialNumber1.3.6.1.4.1.8708.2.11.2.10.1.1.8DisplayStringRO
CequipmentOpticalModuleWarmingUpState1.3.6.1.4.1.8708.2.11.2.10.1.1.9TruthValueWithNARO
CequipmentOpticalModuleFailure1.3.6.1.4.1.8708.2.11.2.10.1.1.10FaultStatusRO

Textual conventions

EquipmentBoardType INTEGER

acd10G(10002) acd2pGbE(10000) acd5pGbE(10001) ad1AB(7) ad1BA(8) ad1c2fotdr(273) ad1cwdm(42) ad1cwdm2F(78) ad1dwdm2F(77) ad1spr(23) ad2AB(9) ad2BA(10) ad2cwdm(43) ad2oaAB(19) ad2oaBA(20) ad2x1cwdm(56) ad2x2cwdm(57) ad4AB(11) ad4BA(12) ad4Even50(140) ad4Odd50(141) ad4dwdm2F(85) adcwdm(22) bsu1x5Even(130) bsu1x5Odd(131) co10(286) co2xOTDR1611(291) co4(228) co5(229) coD40ev(159) coD40eve(160) coD40od(161) coD40ode(162) coD48ev(281) coD48od(282) coD4919(292) coD4923(293) coD4927(294) coD4931(295) coD4935(296) coD4939(297) coD4943(298) coD4947(299) coD4951(300) coD4955(301) coD919926(218) coD919926e(223) coD927934(219) coD927934e(224) coD935942(220) coD935942e(225) coD943950(221) coD943950e(226) coD951958(222) coD951958e(227) codsf20eva(230) codsf20evb(231) codsf24mpo10104(279) codsf2919(242) codsf2922(243) codsf2923(244) codsf2926(245) codsf2927(246) codsf2930(247) codsf2931(248) codsf2934(249) codsf2935(250) codsf2938(251) codsf2939(252) codsf2942(253) codsf2943(254) codsf2946(255) codsf2947(256) codsf2950(257) codsf2951(258) codsf2954(259) codsf2955(260) codsf2958(261) codsf4919(232) codsf4926(233) codsf4927(234) codsf4934(235) codsf4935(236) codsf4942(237) codsf4943(238) codsf4950(239) codsf4951(240) codsf4958(241) compo24(216) coocuD4x4(288) coocuD4x8(289) cooiuc50100(290) cu(1) cu1osc(26) cu2osc(27) cuSfp(88) cuSfpii(158) cuSfpiii(200) dQgbeMxpR(118) dcDk652km100(207) dcDk652km120(208) dcDk652km20(163) dcDk652km40(164) dcDk652km60(165) dcDk652km80(166) dcP652km100(170) dcP652km120(171) dcP652km20(209) dcP652km40(167) dcP652km60(168) dcP652km80(169) du2F8C(62) edu10GLT(10004) edu10GLTS(10005) edu12pGbE(115) edu5GT(10003) edu6pGbE(96) emxp120iie(181) emxp1u(266) emxp1us(267) emxp220iie(196) emxp240iie(201) emxp3(206) emxp40Gii(172) emxp440(269) emxp440q(283) emxp48iie(194) emxp62iie(180) emxp800xh(287) emxp80Gii(142) escon8(46) fha1u1(211) fhau1(210) fhmxp10g(198) fpu1(203) fpuOas2824(60) fpuYm235(84) fxp400gotn(215) gbe10Emxp10G(114) gbe10Emxp10Gii(132) gbe22Emxp10G(121) gbe22Emxp10Gii(129) gbe9Mxp10G(76) gbeMxp10GFEC(116) gxp10G(51) gxp2500(49) gxp2500Sfp(50) hdea1600(274) mROADM1P800(95) mba1(133) mba1SonetDeprecated(134) mba2(135) mba2E(146) mba2EptpSdh(149) mba2EptpSonet(150) mba2SonetDeprecated(136) mba2ptpSdh(147) mba2ptpSonet(148) mdu16cl50g(175) mdu40Even(104) mdu40EvenL(151) mdu40Odd(105) mdu40OddL(152) mdu4Ext2F(79) mdu4ExtAB(92) mdu4ExtBA(93) mdu4Term2F(80) mdu4TermAB(40) mdu4TermBA(41) mdu8Ee(106) mdu8Eo(107) mdu8EvenExt(69) mdu8EvenTerm(70) mdu8Ext(15) mdu8Term(16) mdu8Term2(58) msMxp(109) msMxp10G(127) msMxp10GTCEr(126) msMxp40G(178) msMxpDQgbe(112) msMxpQMS2G5(128) msMxpQMS2G5R(143) msMxpR(111) msTp40G(177) mu2F8C(61) mxp004(18) mxp028(6) mxp100gotn(199) mxp10gotn(179) mxp16(31) mxp200gotn(268) mxp4x2G5(98) mxp4x2G5Oc(124) mxp8(30) mxp8iiSdh(144) mxp8iiSonet(145) mxpmbh1Sdh(137) mxpmbh1Sonet(138) nidGE(20000) nidSfp155(20001) nidSfp2488(20004) nidSfp622(20002) nidSfpVc12(20003) oa(14) oa1x15dBm(47) oa1x17dBm(75) oa1x20dBm(82) oa1x20dBmVg(153) oa1x20dBmVg2(212) oa1x20dBmVgb(277) oa1x21dBmVgEC(284) oa1x26dBm(122) oa1xFG10dBm(101) oa1xLG20dBm(99) oa1xLG20dBmb(275) oa2(21) oa2x15dBm(48) oa2x17dBm(72) oa2x20dBm(83) oa2x20dBmVg(154) oa2x20dBmVg2(213) oa2x20dBmVgb(278) oa2x21dBmVgEC(285) oa2x21seed(189) oa2xFG10dBm(102) oa2xLG20dBm(100) oa2xLG20dBmb(276) oadm2ch(265) oapow1x17dBm(74) oapre1x17dBm(71) oar450c(87) oaraed20lghyb(270) oaraed21hghyb(204) oaraed21hgind(205) obu(28) ocm2p(108) ocm8p(272) ocu2(5) ocu4(17) ocudq(182) ocuseed2p(188) oiuc100200(73) oiuc50100(94) otdr8p(280) oxc16(4) oxc8(3) oypatchcord(190) pcu2p(123) ptio100g(264) ptio10g(214) rfu1(217) roadm1x2G100(155) roadm1x2G50(156) roadm1x4G100(117) roadm1x4f(263) roadm1x8G50(139) roadm1x9f(271) sync2Mhz(29) tgCad86XX02(1056) tgCad86XX04(1055) tgCo10(1010) tgCo11(1011) tgCo12(1012) tgCo14(1014) tgCo15(1015) tgCo16(1016) tgCo4(1001) tgCo5(1005) tgCo6(1006) tgCo7(1007) tgCo8(1008) tgCo9(1009) tgCoBSU1x5ev(1050) tgCoBSU1x5od(1051) tgCoD40ev(1041) tgCoD40eve(1042) tgCoD40od(1043) tgCoD40ode(1044) tgCoD4XXX(1070) tgCoDSF20(1080) tgCoDSF20evA(1081) tgCoDSF20evB(1082) tgCoDSF20odA(1083) tgCoDSF20odB(1084) tgCoDSF2ch9XXAB(1057) tgCoDSF2ch9XXBA(1059) tgCoDSF4ch9XXAB(1058) tgCoDSF4ch9XXBA(1060) tgCoDxxxyyy(1040) tgCoSFBSU1x5ev(1085) tgTco12(2012) tgTco14(2014) tgTcosf2x1b(1061) tgTcosf2x1d(1062) tm100mxp(185) tm100reg(187) tm100tp(186) tm206AddDrop(9870101) tm206Cu(9600201) tm206Cu2(9600202) tm206Fan(9200201) tm206MuxDemux4ch1t4(9813001) tm206MuxDemux4ch5t8(9814001) tm206MuxDemux4chBidir1(9823001) tm206MuxDemux4chBidir2(9823002) tm206MuxDemux4p1ch1t4(9813101) tm206MuxDemux4p1ch5t8(9814101) tm206OSC1(9221001) tm206OSC2(9221002) tm206TAM4xesc(9500101) tm206TAMln2xfc(9510401) tm206TAMln4xesc(9510101) tm206TAMln4xetr(9510201) tm206TAMlnFlex(9510301) tm206TAMlnp2xfc(9510501) tm206tp2x4gfc(9780001) tm4011(184) tm4700(183) tp100gotn(195) tp100gotnii(262) tp10G(24) tp10GBu(65) tp10GClBu(67) tp10GClTc(97) tp10GLAN(44) tp10GLANBu(66) tp10GLANClBu(68) tp10GOtnTc(103) tp10GRC(45) tp10GTcEr(113) tpD10GL(63) tpD10GbE(90) tpD10GbER(91) tpDDGbE(59) tpDDGbER(64) tpDFcC(35) tpDFcD(34) tpDFcDv2(54) tpDFcSfp(55) tpDGbE(13) tpDGbEC(33) tpDGbED(32) tpDGbEDv2(52) tpDGbESfp(53) tpFcGbEC(37) tpFcGbED(36) tpLMr2500(25) tpMr2500(2) tpMr25v2(89) tpQMS(119) tpQMSR(120) tpQMr(39) tpQMri(86) tpTFcD(38) tphex10gotn(193) tpmrHL16G(197) tpmrHL16GUni(202) tpq10Gfec(157) tpq10GfecReg(174) tpq10gfeci(191) tpq10gfecregi(192) tpqmp(173) ts1100AddDrop(870101) ts1100AddDropDouble(850100) ts1100AddDropSingle(870102) ts1100AttenuatorDouble(270001) ts1100Conv1250Cwdm(750000) ts1100Conv2500Cwdm(760000) ts1100DWDMMuxDemux(883101) ts1100DWDMMuxDemuxExt(883001) ts1100Duplexer(812001) ts1100DuplexerDouble(802001) ts1100EthMux4p(220401) ts1100MuxDemux4ch1t4(813001) ts1100MuxDemux4ch5t8(814001) ts1100MuxDemux4chBidir(823000) ts1100MuxDemux4chExtPizza(803100) ts1100MuxDemux4chPizza(803000) ts1100MuxDemux4p1ch1t4(813101) ts1100MuxDemux4p1ch5t8(814101) ts1100MuxDemux8ch(813200) ts1100MuxDemux8ch2(813400) ts1100MuxDemux8chExtPizza(803300) ts1100MuxDemux8chPizza(803200) ts1100MuxDemux8p1ch(813300) ts1100Muxponder10G(590000) ts1100Muxponder10G2(5900002) ts1100Nmb(600100) ts1100Nmb6003(600300) ts1100OPU(250101) ts1100OPUDouble(250201) ts1100Power9000Supply(900000) ts1100Power9048Supply(904800) ts1100Power9122Supply(912200) ts1100Power9148Supply(914800) ts1100Power9220Supply(922000) ts1100PreAmp(261001) ts1100PreAmpDouble(260401) ts1100Tp10G(790000) ts1100Tp10G7910(791000) ts1100Tp10G7910Rep(7910002) ts1100Tp2500Cwdm1(770000) ts1100Tp2x2500Cwdm1(772000) ts1100Tp2x4GFC(740001) ts1100UnivAgg(550000) ts1100UnivAgg2xDGbE(5800002) ts1100UnivAgg2xGbE2xSTM(581000) ts1100UnivAgg3x25GRep(5800004) ts1100UnivAgg3xGbERep(5800003) ts1100UnivAgg3xGbERep2(5810003) ts1100UnivAgg4xGbE(580000) ts1100UnivAgg4xGbE2(5810002) ts1100UnivAggDFC(540002) ts1100UnivAggDGbE(540001) ts1100UnivAggDGbE2(540003) undefined(0) voa2ch(125) voa8ch(81) voa8chii(110) voa8chsfp(176)

The functional type of the board.
At least one type is defined for each combination of
the following properties of the board:

1 - number of interfaces

2 - type of interfaces

3 - the functionality of the board (can usually be inferred from
the types of interfaces)

The application should be able to determine which and how many
interfaces should be instantiated from the type.

Functional types defined so far:

Note: The following type is not in use.

        cu - Control unit

tpMr2500 - Multi-rate 2500 Mb/s transponder

ocu2 - Dual optical coupler unit (2x1:2)

oxc8 - Optical cross-connect 8x8 ports

oxc16 - Optical cross-connect 16x16 ports

mxp028 - Muxponder 2xSTM-4 + 8xSTM-1

ad1AB, ad1BA - Single add-drop units, A/B- and B/A-type

ad2AB, ad2BA - Double add-drop units, A/B- and B/A-type

ad4AB, ad4BA - Quad add-drop units, A/B- and B/A-type

tpDGbE - Dual GbE transponder

oa - Optical amplifier unit

oa2 - Dual Optical amplifier unit

mdu8Ext - Optical mux/demux unit, extension, 8 ports

mdu8Term - Optical mux/demux unit, terminal, 8 ports

ocu4 - Quad optical coupler unit (4x1:2)

Note: The following type is not in use.

        mxp004 - Muxponder 4xSTM-1

ad2oaAB - 2 channel add-drop unit, type A/B  for use with
          optical amplifier

ad2oaBA - 2 channel add-drop unit, type B/A  for use with
          optical amplifier

adcwdm - Single add-drop units for OSC channels.

Note: The following type is not in use.

      ad1spr - 1 channel spur unit

tp10G - 10 Gb/s transponder

tpLMr2500 - 'Lite' version of the Multi-rate 2500 Mb/s transponder

cu1osc - CU with one OSC i/f

cu2osc - CU with two OSC i/fs

obu - Optical band unit

sync2Mhz - 2 MHz synchronization unit

mxp8 - 8 tributaries (STM-1 or STM-4) muxponder

mxp16 - 16 tributaries (STM-1 or STM-4) muxponder

tpDGbED - Dual GbE transponder for DWDM

tpDGbEC - Dual GbE transponder for CWDM

tpDFcD - Dual fiber channel transponder for DWDM

tpDFcC - Dual fiber channel transponder for CWDM

tpFcGbED - Fiber channel and GbE transponder for DWDM

tpFcGbEC - Fiber channel and GbE transponder for CWDM

tpTFcD - Triple fiber channel transponder for DWDM

tpQMr - Quad multirate transponder

mdu4TermAB - Optical mux/demux unit, terminal, type A/B, 4 ports

mdu4TermBA - Optical mux/demux unit, terminal, type B/A, 4 ports

adc1wdm - Single add-drop units for CWDM channels.

adc2wdm - Double add-drop units for CWDM channels.

tp10GLAN - 10 Gb/s LAN DWDM transponder

tp10GRC - 10 Gb/s Rate Concerving DWDM transponder

escon8 - 8 channel ESCON muxponder

tpMr25v2 - Multi-rate 2500 Mb/s transponder version 2

tpD10GbE - Double 10GbE Transponder, Basic Unit

tpD10GbER - Double 10GbE Transponder, repeater

mdu4ExtAB - Optical mux/demux unit, extension, type A/B, 4 ports

mdu4ExtBA - Optical mux/demux unit, extension, type B/A, 4 ports

oiuc50100 - Optical interleaver unit 50/100 GHz

mROADM1P800 - Reconfigurable optical add/drop multiplexer

mxp4x2G5 - 4xSTM-16/10Gb MuxPonder

tp10GOtnTc - 10Gb/s C-band Tunable OTN Transponder

mdu40Even - 40 channel Mux/Demux unit, even 50GHz DWDM

mdu40Odd - 40 channel Mux/Demux unit, odd 50GHz DWDM

mdu8Ee - 8 channel 50GHz Mux/Demux, extension port, even, 100GHz spacing

mdu8Eo - 8 channel 50GHz Mux/Demux, extension port, odd, 100GHz spacing

ocm2p - 2-port Optical Channel Monitor

msMxp - MultiService MuxPonder

voa8chii - 8ch Variable Optical Attenuator - II

msMxpR - MultiService MuxPonder, repeater

msMxpDQgbe - Double Quad MuxPonder

gbe10Emxp10G - 10xGbE/10GbE Ethernet MuxPonder

gbeMxp10GFEC - 10xGbE/10Gb MuxPonder, FEC

roadm1x4G100 - 4-port Reconfigurable optical add/drop multiplexer

dQgbeMxpR - Double Quad GbE MuxPonder, repeater

tpQMS - Quad MultiService transponder

tpQMSR - Quad MultiService transponder, repeater

gbe22Emxp10G - 22xGbE/10GbE Ethernet MuxPonder

mxp4x2G5Oc - 4x2,5G/10Gb MuxPonder in SONET mode

voa2ch - 2ch Variable Optical Attenuator

msMxp10GTCEr - Multiservice Muxponder Tunable 10G ER

msMxp10G - Multiservice Muxponder 10G

msMxpQMS2G5 - 2.5Gb Quad MultiService transponder

gbe22Emxp10Gii - 22xGbE/10GbE Ethernet MuxPonder Next Generation

bsu1x5Even - 1x5 Band Splitter Unit, Even 50 GhZ Spacing

bsu1x5Odd - 1x5 Band Splitter Unit, Odd 50 GhZ Spacing

mba1 - MS Access Collector 8xE1/T1+2xEth SDH/SONET mode

mba1Sonet - Deprecated

mba2 - MS Access Collector 16xE1/T1+4xEth SDH/SONET mode

mba2Sonet - Deprecated

mxpmbh1Sdh - MS Access Hub 4xSTM-1+16xEth SDH mode

mxpmbh1Sonet - MS Access Hub 4xOC-3+16xEth SONET mode

roadm1x8G50 - 8-port Reconfigurable optical add/drop multiplexer

emxp80Gii - 8x10GbE Ethernet MuxPonder-II

msMxpQMS2G5 - 2.5Gb Quad MultiService Repeater

mxp8iiSdh - 8p SDH 2,5G Muxponder v2

mxp8iiSonet - 8p Sonet 2,5G Muxponder v2

mba2E - MS Access Collector 16xE1/T1+4xEth SDH/SONET mode Temp hardend

mba2ptpSdh - MS Access Collector 16xE1/T1+4xEth point to point SDH mode

mba2ptpSonet - MS Access Collector 16xE1/T1+4xEth point to point SONET mode

mba2EptpSdh - MS Access Collector 16xE1/T1+4xEth point to point SDH mode Temp hardend

mba2EptpSonet - MS Access Collector 16xE1/T1+4xEth point to point SONET mode Temp hardend

tpq10Gfec - Quad MultiService 10G FEC Transponder

mstp40g   - Multiservice Transponder 40G

msmxp40G  - Multiservice Muxponder 40G

cuSfpii - CU-SFP/II: CU with 4 SFP OSC ports

coD40ev - Dual fiber DWDM Mux/Demux filter, 40 even channels, 50GHz spacing.
coD40eve - Dual fiber DWDM Mux/Demux filter with 1310 port, 40 even channels, 50 GHz spacing
coD40od - Dual fiber DWDM Mux/Demux filter, 40 odd channels, 50GHz spacing.
coD40ode - Dual fiber DWDM Mux/Demux filter with 1310 port, 40 odd channels, 50 GHz spacing

dcDk652km20 - Dispersion Compensation Module 20 km
dcDk652km40 - Dispersion Compensation Module 40 km
dcDk652km60 - Dispersion Compensation Module 60 km
dcDk652km80 - Dispersion Compensation Module 80 km
dcDk652km100 - Dispersion Compensation Module 100 km
dcDk652km120 - Dispersion Compensation Module 120 km
dcP652km20 - Dispersion Compensation Module 20 km
dcP652km40 - Dispersion Compensation Module 40 km
dcP652km60 - Dispersion Compensation Module 60 km
dcP652km80 - Dispersion Compensation Module 80 km
dcP652km100 - Dispersion Compensation Module 100 km
dcP652km120 - Dispersion Compensation Module 120 km

emxp40Gii - 4x10GbE Ethernet MuxPonder-II

tpqmp - Quad MultiProtocol Transponder

tpq10GfecReg - Quad MultiService 10G FEC Regenerator

mdu16cl50g - Colorless Mux/Demux Unit

voa8chsfp - 8ch SFP-based VOA unit

mxp10gotn - OTN Muxponder 10G

ocudq - Optical Coupler Unit, Dual Quad (2x1:4)

ocuseed2p - 2-Port Seed Light coupler Unit

tm4700 - TM2000 Shelf Controller

tm4011 - TM2000 40Gb/s Muxponder

tm100mxp - TM2000 100Gb/s Muxponder

tm100tp - TM2000 100Gb/s Transponder

tm100reg - TM2000 100Gb/s Regenerator

oypatchcord - Optical Y-patch cord

tpq10gfeci - Quad 10G FEC Transponder 1-slot

tpq10gfecregi - Quad MultiService 10G FEC Regenerator 1-slot

tphex10gotn - Hex 10G OTN Transponder

tp100gotn - 100G OTN Transponder

emxp220iie - 1x100GbE Ethernet MuxPonder-IIe

tpmrHL16G - Hex MultiRate 16G Lite Transponder

fhmxp10g - Fronthaul Muxponder 10G

mxp100gotn - 100G OTN Muxponder

fpu1 - Fiber Protection Unit

oaraed21hghyb - RAMAN/EDFA 21dBm HG hybrid board

oaraed21hgind - RAMAN/EDFA 21dBm HG individual board

emxp3 - 8xMPO Ethernet MuxPonder-III

ptio10g - PT Fabric i/O Unit 10&t

fhau1 - Fronthaul Access Unit FHAU/1

fha1u1 - Hardened Fronthaul Access Unit

tpmrHL16GUni - Hex MultiRate 16G Lite Transponder - - Unidirectional

oa1x20dBmVg2 - Variable Gain EDFA 20dBm v2

oa2x20dBmVg2 - Dual Variable Gain EDFA 20dBm v2

fxp400gotn - 400G OTN Flexponder

compo24 - CO-MPO24 CO-MPO24

tp100gotnii - 100G OTN Transponder-II

rfu1  - Remote Fronthaul Unit

roadm1x4f - 4-port Flex Reconfigurable optical add/drop multiplexer

ptio100g - PT Fabric I/O Unit 100&t

oadm2ch - 2ch DWDM OADM

emxp1u - Hardened EMXP Unit

emxp1us - Hardened EMXP with SDN

mxp200gotn - 200G OTN Muxponder

emxp440 - 440GbE Ethernet MuxPonder-III

emxp440q - 440GbE Q Ethernet MuxPonder-III

oaraed20lghyb - RAMAN/EDFA 20dBm LG hybrid board

roadm1x9f - 9-port Flex Reconfigurable optical add/drop multiplexer

ocm8p - 8-port Optical Channel Monitor

ad1c2fotdr - 1ch CWDM add/drop filter with 1610nm OTDR

hdea1600 - High Density Ethernet Aggregator

codsf24mpo10104 - Filter for HDEA1600

otdr8p - Optical Time Domain Reflectometer

oa1x21dBmVgEC - Variable Gain Extended C-band EDFA 21dBm

oa2x21dBmVgEC - Dual Variable Gain Extended C-band EDFA 21dBm

emxp800xh - Ethernet Muxponder 800 XHAUL
EquipmentSubrackType INTEGER

aux(6) mba1(8) mba2(9) mba2E(10) tm101(4) tm101p(5) tm102(7) tm102pas(11) tm102pas3(12) tm2000(14) tm206Subrack6Slots(9006) tm300(1) tm3000(2) tm3000ii(13) tm3000iie(20) tm301(3) tm301ii(15) tmEmxp1UDc(18) tmEmxpXh800Dc(21) tmFha1UDc1(16) tmHdea1600Dc(19) tmRfuAc1(17) ts1100Subrack12Slots(9013) ts1100Subrack2Slots(9002) ts1100Subrack8Slots(9011) undefined(0)

The type of subrack:

tm300 - The small subrack (old).

tm3000 - The big subrack.

tm3000ii - The big subrack, enhanced version.

tm3000iie - The big subrack, enhanced second version.

tm301 - The small subrack (new).

tm301ii - A subrack for maximum four traffic boards, enhanced version.
tm101  - Pizza box subrack.

tm101p - Passive pizza box subrack.

tm102 - An even smaller pizza box.

mba1 - Monolith for mobile access

mba2 - Monolith for mobile access

mba2E - Monolith for mobile access temp hardened

tm102pas - Passive pizza box subrack with one full-
           sized slot and one half-sized slot.

tm102pas3 - Passive pizza box subrack with three
            half-sized slots.

tm101p - Passive pizza box subrack.

tm2000 - Small subrack for 100 Gbps boards.

aux - virtual subrack for external equipment.

tmFha1UDc1 - Monolith for mobile front haul.

tmRfuAc1 - Remote mobile front haul unit.

tmEmxp1UDc - Emxp temp hardened unit.

tmHdea1600Dc - Hdea1600 subrack.

tmEmxpXh800G/DC - Emxp 800 XHAUL subrack.
FirstPbSlot INTEGER

slot13(13) slot3(3) slot4(4) undefined(0)

A value indicating the first slot where it is
possible to configure a passive board in a subrack.

undefined - indicates that no value has yet been set.

slot3 - Slot 3 is the first passive slot.

slot4 - Slot 4 is the first passive slot.

slot13 - Slot 13 is the first passive slot.

Traps / Notifications