LUM-EQUIPMENT-MIB
Nokia (formerly 'Lumentis AB')The common equipment configuration MIB. - General - Subrack status - Board configuration and status - Power supply status - Fan status - Slot
snmptranslate -m LUM-EQUIPMENT-MIB -Tpsnmpwalk -v2c -c <community> -m LUM-EQUIPMENT-MIB <host> 1.3.6.1.4.1.8708.1.1.12Imports
| LUM-ALARM-MIB | AlarmPerceivedSeverity |
|---|---|
| LUM-REG | lumEquipmentMIB, lumModules |
| LUM-TC | AdminStatus, BoardOrInterfaceAdminStatus, BoardOrInterfaceOperStatus, CommandString, FaultStatus, MgmtNameString, ObjectProperty, SlotNumber, SubrackNumber, TruthValueWithNA |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DateAndTime, DisplayString, PhysAddress, RowStatus, TEXTUAL-CONVENTION, TestAndIncr |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IlumEquipmentMIBModule | 1.3.6.1.4.1.8708.1.1.12 | ||||||||||||||||||||
identity The common equipment configuration MIB. - General - Subrack status - Board configuration and status - Power supply status - Fan status - Slot | |||||||||||||||||||||
| NlumEquipmentConfs | 1.3.6.1.4.1.8708.2.11.1 | ||||||||||||||||||||
| NlumEquipmentGroups | 1.3.6.1.4.1.8708.2.11.1.1 | ||||||||||||||||||||
| GequipmentGeneralGroup | 1.3.6.1.4.1.8708.2.11.1.1.1 | ||||||||||||||||||||
group · current The general objects. | |||||||||||||||||||||
| GequipmentSubrackGroup | 1.3.6.1.4.1.8708.2.11.1.1.2 | deprecated | |||||||||||||||||||
group · deprecated The subrack module objects. | |||||||||||||||||||||
| GequipmentBoardGroup | 1.3.6.1.4.1.8708.2.11.1.1.3 | deprecated | |||||||||||||||||||
group · deprecated The board objects.
| |||||||||||||||||||||
| GequipmentPowerGroup | 1.3.6.1.4.1.8708.2.11.1.1.4 | deprecated | |||||||||||||||||||
group · deprecated The power module objects.
| |||||||||||||||||||||
| GequipmentFanGroup | 1.3.6.1.4.1.8708.2.11.1.1.5 | deprecated | |||||||||||||||||||
group · deprecated The fan module objects. | |||||||||||||||||||||
| GequipmentGeneralGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.6 | deprecated | |||||||||||||||||||
| GequipmentNotificationGroup | 1.3.6.1.4.1.8708.2.11.1.1.7 | deprecated | |||||||||||||||||||
group · deprecated The equipment notifications. | |||||||||||||||||||||
| GequipmentSubrackGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.8 | deprecated | |||||||||||||||||||
group · deprecated The subrack module objects V2. | |||||||||||||||||||||
| GequipmentSubrackGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.9 | deprecated | |||||||||||||||||||
group · deprecated The subrack module objects V3. | |||||||||||||||||||||
| GequipmentBoardGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.10 | deprecated | |||||||||||||||||||
group · deprecated The board objects V2.
| |||||||||||||||||||||
| GequipmentNodeGroup | 1.3.6.1.4.1.8708.2.11.1.1.11 | deprecated | |||||||||||||||||||
| GequipmentGeneralGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.12 | deprecated | |||||||||||||||||||
group · deprecated The equipment general objects v3. | |||||||||||||||||||||
| GequipmentNodeGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.13 | deprecated | |||||||||||||||||||
| GequipmentNodeGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.14 | deprecated | |||||||||||||||||||
group · deprecated The node objects. | |||||||||||||||||||||
| GequipmentSubrackGroupV4 | 1.3.6.1.4.1.8708.2.11.1.1.15 | deprecated | |||||||||||||||||||
group · deprecated The subrack module objects V4.
| |||||||||||||||||||||
| GequipmentBoardGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.16 | deprecated | |||||||||||||||||||
group · deprecated The board objects V3.
| |||||||||||||||||||||
| GequipmentNotificationGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.17 | deprecated | |||||||||||||||||||
group · deprecated The equipment notifications. | |||||||||||||||||||||
| GequipmentSubrackGroupV5 | 1.3.6.1.4.1.8708.2.11.1.1.18 | deprecated | |||||||||||||||||||
group · deprecated The subrack module objects V5. (2.2)
| |||||||||||||||||||||
| GequipmentFanGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.19 | deprecated | |||||||||||||||||||
group · deprecated The fan module objects. | |||||||||||||||||||||
| GequipmentGeneralGroupV4 | 1.3.6.1.4.1.8708.2.11.1.1.20 | deprecated | |||||||||||||||||||
group · deprecated The equipment general objects v4 (3.1). | |||||||||||||||||||||
| GequipmentSubrackGroupV6 | 1.3.6.1.4.1.8708.2.11.1.1.21 | deprecated | |||||||||||||||||||
group · deprecated The subrack module objects V6. (4.0)
| |||||||||||||||||||||
| GequipmentBoardGroupV4 | 1.3.6.1.4.1.8708.2.11.1.1.22 | deprecated | |||||||||||||||||||
group · deprecated The board objects V4. (4.0)
| |||||||||||||||||||||
| GequipmentPowerGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.23 | deprecated | |||||||||||||||||||
group · deprecated The power module objects (4.0).
| |||||||||||||||||||||
| GequipmentFanGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.24 | deprecated | |||||||||||||||||||
group · deprecated The fan module objects (4.0). | |||||||||||||||||||||
| GequipmentNodeGroupV4 | 1.3.6.1.4.1.8708.2.11.1.1.25 | deprecated | |||||||||||||||||||
group · deprecated The node objects V4 (7.0) | |||||||||||||||||||||
| GequipmentBoardGroupV5 | 1.3.6.1.4.1.8708.2.11.1.1.26 | deprecated | |||||||||||||||||||
group · deprecated The board objects V5. (7.0)
| |||||||||||||||||||||
| GequipmentBoardGroupV6 | 1.3.6.1.4.1.8708.2.11.1.1.27 | deprecated | |||||||||||||||||||
group · deprecated The board objects V6. (8.0)
| |||||||||||||||||||||
| GequipmentBoardGroupV7 | 1.3.6.1.4.1.8708.2.11.1.1.28 | deprecated | |||||||||||||||||||
group · deprecated The board objects V7. (9.0)
| |||||||||||||||||||||
| GequipmentNodeGroupV8 | 1.3.6.1.4.1.8708.2.11.1.1.29 | deprecated | |||||||||||||||||||
group · deprecated The node objects V8 (11.0) | |||||||||||||||||||||
| GequipmentBoardGroupV8 | 1.3.6.1.4.1.8708.2.11.1.1.30 | deprecated | |||||||||||||||||||
group · deprecated The board objects V8. (12.0)
| |||||||||||||||||||||
| GequipmentNodeGroupV9 | 1.3.6.1.4.1.8708.2.11.1.1.31 | deprecated | |||||||||||||||||||
group · deprecated The node objects V9 (14.0) | |||||||||||||||||||||
| GequipmentResourceGroup | 1.3.6.1.4.1.8708.2.11.1.1.32 | ||||||||||||||||||||
group · current The resouce objects V1 (16.0) | |||||||||||||||||||||
| GequipmentSubrackGroupV7 | 1.3.6.1.4.1.8708.2.11.1.1.33 | deprecated | |||||||||||||||||||
group · deprecated The subrack module objects V7. (16.0)
| |||||||||||||||||||||
| GequipmentSubrackGroupV8 | 1.3.6.1.4.1.8708.2.11.1.1.34 | deprecated | |||||||||||||||||||
group · deprecated The subrack module objects V8. (17.0)
| |||||||||||||||||||||
| GequipmentBoardGroupV9 | 1.3.6.1.4.1.8708.2.11.1.1.35 | deprecated | |||||||||||||||||||
group · deprecated The board objects V9. (17.0)
| |||||||||||||||||||||
| GequipmentNotificationGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.36 | ||||||||||||||||||||
group · current The equipment notifications. | |||||||||||||||||||||
| GequipmentBoardGroupV10 | 1.3.6.1.4.1.8708.2.11.1.1.37 | deprecated | |||||||||||||||||||
group · deprecated The board objects V10. (17.0)
| |||||||||||||||||||||
| GequipmentNodeGroupV10 | 1.3.6.1.4.1.8708.2.11.1.1.38 | deprecated | |||||||||||||||||||
group · deprecated The node objects V10 (18.0) | |||||||||||||||||||||
| GequipmentBoardGroupV11 | 1.3.6.1.4.1.8708.2.11.1.1.40 | deprecated | |||||||||||||||||||
group · deprecated The board objects V11. (20.0)
| |||||||||||||||||||||
| GequipmentFanGroupV4 | 1.3.6.1.4.1.8708.2.11.1.1.41 | deprecated | |||||||||||||||||||
group · deprecated The fan module objects V4. (20.0) | |||||||||||||||||||||
| GequipmentSlotGroup | 1.3.6.1.4.1.8708.2.11.1.1.42 | deprecated | |||||||||||||||||||
group · deprecated The slot module objects. (20.0) | |||||||||||||||||||||
| GequipmentBoardGroupV12 | 1.3.6.1.4.1.8708.2.11.1.1.43 | deprecated | |||||||||||||||||||
group · deprecated The board objects V12. (21.0)
| |||||||||||||||||||||
| GequipmentNodeGroupV11 | 1.3.6.1.4.1.8708.2.11.1.1.44 | ||||||||||||||||||||
group · current The node objects V11 (21.0) | |||||||||||||||||||||
| GequipmentBoardGroupV13 | 1.3.6.1.4.1.8708.2.11.1.1.45 | deprecated | |||||||||||||||||||
group · deprecated The board objects V13. (27.0)
| |||||||||||||||||||||
| GequipmentPowerGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.46 | deprecated | |||||||||||||||||||
group · deprecated The power module objects V3 (27.0).
| |||||||||||||||||||||
| GequipmentBoardGroupV14 | 1.3.6.1.4.1.8708.2.11.1.1.47 | ||||||||||||||||||||
group · current The board objects V14. (28.0)
| |||||||||||||||||||||
| GequipmentSlotGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.48 | ||||||||||||||||||||
group · current The slot module objects V2. (28.0) | |||||||||||||||||||||
| GequipmentSubrackGroupV9 | 1.3.6.1.4.1.8708.2.11.1.1.49 | deprecated | |||||||||||||||||||
group · deprecated The subrack module objects V9. (28.0)
| |||||||||||||||||||||
| GequipmentPowerGroupV4 | 1.3.6.1.4.1.8708.2.11.1.1.50 | deprecated | |||||||||||||||||||
group · deprecated The power module objects V4 (28.0).
| |||||||||||||||||||||
| GequipmentFanGroupV5 | 1.3.6.1.4.1.8708.2.11.1.1.51 | ||||||||||||||||||||
group · current The fan module objects V5. (28.0)
| |||||||||||||||||||||
| GequipmentGeneralGroupV5 | 1.3.6.1.4.1.8708.2.11.1.1.52 | deprecated | |||||||||||||||||||
group · deprecated The equipment general objects v5 (R28.0). | |||||||||||||||||||||
| GequipmentSubrackGroupV10 | 1.3.6.1.4.1.8708.2.11.1.1.53 | ||||||||||||||||||||
group · current The subrack module objects V10. (29.0)
| |||||||||||||||||||||
| GequipmentGeneralGroupV6 | 1.3.6.1.4.1.8708.2.11.1.1.54 | ||||||||||||||||||||
group · current The equipment general objects v6 (R31.0).
| |||||||||||||||||||||
| GequipmentOpticalModuleGroup | 1.3.6.1.4.1.8708.2.11.1.1.55 | ||||||||||||||||||||
group · current The equipment optical module objects v6 (R31.0).
| |||||||||||||||||||||
| GequipmentPowerGroupV5 | 1.3.6.1.4.1.8708.2.11.1.1.56 | ||||||||||||||||||||
group · current The power module objects V5 (32.1).
| |||||||||||||||||||||
| NlumEquipmentCompl | 1.3.6.1.4.1.8708.2.11.1.2 | ||||||||||||||||||||
| MlumEquipmentBasicComplV1 | 1.3.6.1.4.1.8708.2.11.1.2.1 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB. | |||||||||||||||||||||
| MlumEquipmentBasicComplV2 | 1.3.6.1.4.1.8708.2.11.1.2.2 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V2. | |||||||||||||||||||||
| MlumEquipmentBasicComplV3 | 1.3.6.1.4.1.8708.2.11.1.2.3 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V3. | |||||||||||||||||||||
| MlumEquipmentBasicComplV4 | 1.3.6.1.4.1.8708.2.11.1.2.4 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V4. | |||||||||||||||||||||
| MlumEquipmentBasicComplV5 | 1.3.6.1.4.1.8708.2.11.1.2.5 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V5. | |||||||||||||||||||||
| MlumEquipmentBasicComplV6 | 1.3.6.1.4.1.8708.2.11.1.2.6 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V6. | |||||||||||||||||||||
| MlumEquipmentBasicComplV7 | 1.3.6.1.4.1.8708.2.11.1.2.7 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V7. | |||||||||||||||||||||
| MlumEquipmentBasicComplV8 | 1.3.6.1.4.1.8708.2.11.1.2.8 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V8. | |||||||||||||||||||||
| MlumEquipmentBasicComplV9 | 1.3.6.1.4.1.8708.2.11.1.2.9 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V9. | |||||||||||||||||||||
| MlumEquipmentBasicComplV10 | 1.3.6.1.4.1.8708.2.11.1.2.10 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V10. | |||||||||||||||||||||
| MlumEquipmentBasicComplV11 | 1.3.6.1.4.1.8708.2.11.1.2.11 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V11. Equivalent to V10, but the notifications differ... | |||||||||||||||||||||
| MlumEquipmentBasicComplV12 | 1.3.6.1.4.1.8708.2.11.1.2.12 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V12. | |||||||||||||||||||||
| MlumEquipmentBasicComplV13 | 1.3.6.1.4.1.8708.2.11.1.2.13 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V13. (2.2) | |||||||||||||||||||||
| MlumEquipmentBasicComplV14 | 1.3.6.1.4.1.8708.2.11.1.2.14 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V14. (2.3) | |||||||||||||||||||||
| MlumEquipmentBasicComplV15 | 1.3.6.1.4.1.8708.2.11.1.2.15 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V15. (2.3.2) | |||||||||||||||||||||
| MlumEquipmentBasicComplV16 | 1.3.6.1.4.1.8708.2.11.1.2.16 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V16. (3.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV17 | 1.3.6.1.4.1.8708.2.11.1.2.17 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V17. (3.1) | |||||||||||||||||||||
| MlumEquipmentBasicComplV18 | 1.3.6.1.4.1.8708.2.11.1.2.18 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V18. (4.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV19 | 1.3.6.1.4.1.8708.2.11.1.2.19 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V19. (7.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV20 | 1.3.6.1.4.1.8708.2.11.1.2.20 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V20. (8.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV21 | 1.3.6.1.4.1.8708.2.11.1.2.21 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V21. (9.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV22 | 1.3.6.1.4.1.8708.2.11.1.2.22 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V22. (10.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV23 | 1.3.6.1.4.1.8708.2.11.1.2.23 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V23. (11.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV24 | 1.3.6.1.4.1.8708.2.11.1.2.24 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V24. (12.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV25 | 1.3.6.1.4.1.8708.2.11.1.2.25 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V24. (14.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV26 | 1.3.6.1.4.1.8708.2.11.1.2.26 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V26. (16.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV27 | 1.3.6.1.4.1.8708.2.11.1.2.27 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V26. (16.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV28 | 1.3.6.1.4.1.8708.2.11.1.2.28 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V28. (17.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV29 | 1.3.6.1.4.1.8708.2.11.1.2.29 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V28. (17.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV30 | 1.3.6.1.4.1.8708.2.11.1.2.30 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V30. (18.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV31 | 1.3.6.1.4.1.8708.2.11.1.2.31 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V31. (20.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV32 | 1.3.6.1.4.1.8708.2.11.1.2.32 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V32. (21.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV33 | 1.3.6.1.4.1.8708.2.11.1.2.33 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V33. (27.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV34 | 1.3.6.1.4.1.8708.2.11.1.2.34 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V34. (28.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV35 | 1.3.6.1.4.1.8708.2.11.1.2.35 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V35. (29.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV36 | 1.3.6.1.4.1.8708.2.11.1.2.36 | deprecated | |||||||||||||||||||
compliance · deprecated Basic implementation requirements for the equipment MIB V36. (31.0) | |||||||||||||||||||||
| MlumEquipmentBasicComplV37 | 1.3.6.1.4.1.8708.2.11.1.2.37 | ||||||||||||||||||||
compliance · current Basic implementation requirements for the equipment MIB V37. (32.1) | |||||||||||||||||||||
| NlumEquipmentMinimalGroups | 1.3.6.1.4.1.8708.2.11.1.3 | ||||||||||||||||||||
| GequipmentGeneralMinimalGroupV1 | 1.3.6.1.4.1.8708.2.11.1.3.1 | ||||||||||||||||||||
group · current The minimal general equipment MIB objects. | |||||||||||||||||||||
| GequipmentBoardMinimalGroupV1 | 1.3.6.1.4.1.8708.2.11.1.3.2 | deprecated | |||||||||||||||||||
group · deprecated The minimal board objects. | |||||||||||||||||||||
| GequipmentBoardMinimalGroupV2 | 1.3.6.1.4.1.8708.2.11.1.3.3 | ||||||||||||||||||||
group · current The minimal board objects.
| |||||||||||||||||||||
| NlumEquipmentMinimalCompl | 1.3.6.1.4.1.8708.2.11.1.4 | ||||||||||||||||||||
| MlumEquipmentMinimalComplV1 | 1.3.6.1.4.1.8708.2.11.1.4.1 | deprecated | |||||||||||||||||||
compliance · deprecated Minimal implementation requirements for the equipment MIB V1. | |||||||||||||||||||||
| MlumEquipmentMinimalComplV2 | 1.3.6.1.4.1.8708.2.11.1.4.2 | deprecated | |||||||||||||||||||
compliance · deprecated Minimal implementation requirements for the equipment MIB V2. | |||||||||||||||||||||
| MlumEquipmentMinimalComplV3 | 1.3.6.1.4.1.8708.2.11.1.4.3 | deprecated | |||||||||||||||||||
compliance · deprecated Minimal implementation requirements for the equipment MIB V3. | |||||||||||||||||||||
| MlumEquipmentMinimalComplV4 | 1.3.6.1.4.1.8708.2.11.1.4.4 | ||||||||||||||||||||
compliance · current Minimal implementation requirements for the equipment MIB V4. | |||||||||||||||||||||
| MlumEquipmentMinimalComplV5 | 1.3.6.1.4.1.8708.2.11.1.4.5 | deprecated | |||||||||||||||||||
compliance · deprecated Minimal implementation requirements for the equipment MIB V5. | |||||||||||||||||||||
| MlumEquipmentMinimalComplV6 | 1.3.6.1.4.1.8708.2.11.1.4.6 | ||||||||||||||||||||
compliance · current Minimal implementation requirements for the equipment MIB V6. | |||||||||||||||||||||
| NlumEquipmentMIBObjects | 1.3.6.1.4.1.8708.2.11.2 | ||||||||||||||||||||
| NequipmentGeneral | 1.3.6.1.4.1.8708.2.11.2.1 | ||||||||||||||||||||
| SequipmentGeneralTestAndIncr | 1.3.6.1.4.1.8708.2.11.2.1.1 | TestAndIncr | RW | ||||||||||||||||||
scalar · TestAndIncr · read-write · current Protection against simultaneous access from multiple managers. See SNMPv2-TC. | |||||||||||||||||||||
| SequipmentGeneralMibSpecVersion | 1.3.6.1.4.1.8708.2.11.2.1.2 | DisplayString | RW | ||||||||||||||||||
scalar · DisplayString · read-write · current The MIB specification version. tbd: persistent? | |||||||||||||||||||||
| SequipmentGeneralMibImplVersion | 1.3.6.1.4.1.8708.2.11.2.1.3 | DisplayString | RW | ||||||||||||||||||
scalar · DisplayString · read-write · current The MIB implementation version. | |||||||||||||||||||||
| SequipmentGeneralLastChangeTime | 1.3.6.1.4.1.8708.2.11.2.1.4 | DateAndTime | RO | ||||||||||||||||||
scalar · DateAndTime · read-only · current The time when the configuration of the MIB was last changed. | |||||||||||||||||||||
| SequipmentGeneralStateLastChangeTime | 1.3.6.1.4.1.8708.2.11.2.1.5 | DateAndTime | RO | ||||||||||||||||||
scalar · DateAndTime · read-only · current The time when the state of the MIB was last changed. | |||||||||||||||||||||
| SequipmentGeneralEquipmentSubrackTableSize | 1.3.6.1.4.1.8708.2.11.2.1.6 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current Size of table | |||||||||||||||||||||
| SequipmentGeneralEquipmentBoardTableSize | 1.3.6.1.4.1.8708.2.11.2.1.7 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current Size of table | |||||||||||||||||||||
| SequipmentGeneralEquipmentPowerTableSize | 1.3.6.1.4.1.8708.2.11.2.1.8 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current Size of table | |||||||||||||||||||||
| SequipmentGeneralEquipmentFanTableSize | 1.3.6.1.4.1.8708.2.11.2.1.9 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current Size of table | |||||||||||||||||||||
| SequipmentGeneralEquipmentSlotTableSize | 1.3.6.1.4.1.8708.2.11.2.1.10 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current Size of table | |||||||||||||||||||||
| SequipmentGeneralEquipmentOpticalModuleTableSize | 1.3.6.1.4.1.8708.2.11.2.1.11 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current Size of table | |||||||||||||||||||||
| NequipmentSubrackList | 1.3.6.1.4.1.8708.2.11.2.2 | ||||||||||||||||||||
| TequipmentSubrackTable | 1.3.6.1.4.1.8708.2.11.2.2.1 | NA | |||||||||||||||||||
table · not-accessible · current The subrack list. | |||||||||||||||||||||
| RequipmentSubrackEntry | 1.3.6.1.4.1.8708.2.11.2.2.1.1 | NA | |||||||||||||||||||
| CequipmentSubrackIndex | 1.3.6.1.4.1.8708.2.11.2.2.1.1.1 | Unsigned32 (1..2147483647) | RO | 1 | |||||||||||||||||
column · Unsigned32 (1..2147483647) · read-only · current An arbitrary index assigned to each subrack entry. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackName | 1.3.6.1.4.1.8708.2.11.2.2.1.1.2 | MgmtNameString | RO | tm3000ii:1 | |||||||||||||||||
column · MgmtNameString · read-only · current The name of the subrack, for example 'sub1' where the number indicates the subrack number. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackSubrack | 1.3.6.1.4.1.8708.2.11.2.2.1.1.3 | SubrackNumber | RC | 1 | |||||||||||||||||
column · SubrackNumber · read-create · current The number of the subrack. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackDescr | 1.3.6.1.4.1.8708.2.11.2.2.1.1.4 | DisplayString | RW | | |||||||||||||||||
column · DisplayString · read-write · current User configurable label. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackInvPhysIndexOrZero | 1.3.6.1.4.1.8708.2.11.2.2.1.1.5 | Unsigned32 (0..2147483647) | RO | 100000000 | |||||||||||||||||
column · Unsigned32 (0..2147483647) · read-only · current The row in the invPhysTable for this subrack. Set to 0 if not known. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackAllFanUnitsFailed | 1.3.6.1.4.1.8708.2.11.2.2.1.1.6 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current All fan units in a subrack have failed. A(ctivation): fanUnitFailed active for all fans within a subrack. D(e-activiation): fanUnitFailed cleared for one fan unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackRowStatus | 1.3.6.1.4.1.8708.2.11.2.2.1.1.7 | RowStatus | RC | 1 | |||||||||||||||||
column · RowStatus · read-create · current SNMP administrivia. Manages creation and deletion of conceptual rows. See also SNMPv2-TC. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackExpectedType | 1.3.6.1.4.1.8708.2.11.2.2.1.1.8 | EquipmentSubrackType | RW | 13 | |||||||||||||||||
column · EquipmentSubrackType · read-write · current The expected subrack type. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackActualType | 1.3.6.1.4.1.8708.2.11.2.2.1.1.9 | EquipmentSubrackType | RO | 13 | |||||||||||||||||
column · EquipmentSubrackType · read-only · current The actual subrack type. If an unexpected subrack has been detected this variable can be used to see what type of subrack has been detected. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackUnexpectedType | 1.3.6.1.4.1.8708.2.11.2.2.1.1.10 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current A type of subrack not matching the expected type is present. A: A subrack with type different from the expected type is present (even if the subrack is not activated). D: The type matches the expected or no subrack is present. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackTemp | 1.3.6.1.4.1.8708.2.11.2.2.1.1.11 | Integer32 (-1000..1000) | RO | 372 | |||||||||||||||||
column · Integer32 (-1000..1000) · read-only · current The temperature in the subrack in 0.1 degrees centigrade. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackTempHighExceeded | 1.3.6.1.4.1.8708.2.11.2.2.1.1.12 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The threshold for environmental temperature in the subrack is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degrees centigrade below the associated threshold. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackTempThreshold | 1.3.6.1.4.1.8708.2.11.2.2.1.1.13 | Integer32 (-100..800) | RW | 550 | |||||||||||||||||
column · Integer32 (-100..800) · read-write · current The threshold for temperature alarm in the subrack in 0.1 degrees centigrade. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackDataChanged | 1.3.6.1.4.1.8708.2.11.2.2.1.1.14 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The subrack data (dipswitches for subrackId and/or system mode) has been changed. Changing this data might affect the system behaviour after the next restart. A: The subrack data has been changed since startup D: The subrack data is changed back to the value read at startup, or the system is restarted. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackSystemModeSet | 1.3.6.1.4.1.8708.2.11.2.2.1.1.15 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The value read from the system mode dipswitches at startup of the CU was diffrent from 0. This will affect the behaviour of the system. If the lowest bit is set, the backup is read from the TUs - useful at CU replacement. A: The system mode is different from 0 at startup. D: The system mode is 0 at startup. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackEffectiveSystemMode | 1.3.6.1.4.1.8708.2.11.2.2.1.1.16 | Unsigned32 (0..2147483647) | RO | 0 | |||||||||||||||||
column · Unsigned32 (0..2147483647) · read-only · current The value of the system mode dipswitches read at startup. This value determines the system behaviour. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackCurrentSystemMode | 1.3.6.1.4.1.8708.2.11.2.2.1.1.17 | Unsigned32 (0..2147483647) | RO | 0 | |||||||||||||||||
column · Unsigned32 (0..2147483647) · read-only · current The current value of the system mode dipswitches. Will be used at the next restart. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackAdminStatus | 1.3.6.1.4.1.8708.2.11.2.2.1.1.18 | INTEGER | RW | up(2) | |||||||||||||||||
column · INTEGER · read-write · current The administrative state of the subrack. down - This subrack should not be monitored. Suppresses alarms. up - The subrack should be monitored.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackOperStatus | 1.3.6.1.4.1.8708.2.11.2.2.1.1.19 | INTEGER | RO | up(3) | |||||||||||||||||
column · INTEGER · read-only · current The operational state of the subrack. notPresent - The subrack is not available. down - The subrack remains in the 'down'-state when adminStatus is set to 'down'. up - The subrack is active and monitored.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackObjectProperty | 1.3.6.1.4.1.8708.2.11.2.2.1.1.20 | ObjectProperty | RO | 0 | |||||||||||||||||
column · ObjectProperty · read-only · current Property mask. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackShelfLength | 1.3.6.1.4.1.8708.2.11.2.2.1.1.21 | Unsigned32 (0..32) | RW | 0 | |||||||||||||||||
column · Unsigned32 (0..32) · read-write · current Length of the half-height slot divider shelf. To be manually entered by the user. A value of 0 is interpreted as 'not yet defined by user'. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackLANModuleMissing | 1.3.6.1.4.1.8708.2.11.2.2.1.1.22 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The subrack LAN/DCN module is missing.
A(ctivation): LAN/DCN module disconnected from subrack
for more than 2 seconds.
D(e-activiation): LAN/DCN module connected to subrack
for more than 2 seconds.Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackExpectedFirstPbSlot | 1.3.6.1.4.1.8708.2.11.2.2.1.1.23 | FirstPbSlot | RW | 0 | |||||||||||||||||
column · FirstPbSlot · read-write · current The lowest slot number where it is possible to configure a passive board. Automatically configured to the actual value supported by hardware if the hardware is present on subrack configuration. If no hardware is present at configuration time, this value is set to 'undefined' until changed by the user. The 'undefined' value allows passive board configuration in the same slots as the highest possible firstPbSlot setting of the subrack type. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackActualFirstPbSlot | 1.3.6.1.4.1.8708.2.11.2.2.1.1.24 | FirstPbSlot | RO | 4 | |||||||||||||||||
column · FirstPbSlot · read-only · current The actual lowest slot number where it is possible to configure a passive board. When no subrack hardware is present, this value is 'undefined'. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackFirstPbSlotMismatch | 1.3.6.1.4.1.8708.2.11.2.2.1.1.25 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The expected first passive slot allows more passive
boards than the hardware supports.
A(ctivation): A subrack and control unit combination
which supports fewer passive boards
than configured is present.
D(e-activiation): A subrack and control unit
combination which supports the
current configuration is present.Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackAid | 1.3.6.1.4.1.8708.2.11.2.2.1.1.26 | DisplayString | RO | SUB-1 | |||||||||||||||||
column · DisplayString · read-only · current The access identifier (AID) of the product. The format is according to GR-833. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackPhysicalLocation | 1.3.6.1.4.1.8708.2.11.2.2.1.1.27 | DisplayString | RO | SUB-1 | |||||||||||||||||
column · DisplayString · read-only · current The Physical location of the product. The format is according to GR-833. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentSubrackChangeExpectedType | 1.3.6.1.4.1.8708.2.11.2.2.1.1.28 | CommandString | RO | ||||||||||||||||||
column · CommandString · read-only · current Command to change expected type, used when upgrading subrack to a new version, e.g TM3000 to TM3000/II | |||||||||||||||||||||
| NequipmentBoardList | 1.3.6.1.4.1.8708.2.11.2.3 | ||||||||||||||||||||
| TequipmentBoardTable | 1.3.6.1.4.1.8708.2.11.2.3.1 | NA | |||||||||||||||||||
table · not-accessible · current The board list. | |||||||||||||||||||||
| RequipmentBoardEntry | 1.3.6.1.4.1.8708.2.11.2.3.1.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the board list. One entry for each slot.
| |||||||||||||||||||||
| CequipmentBoardIndex | 1.3.6.1.4.1.8708.2.11.2.3.1.1.1 | Unsigned32 (1..2147483647) | RO | 10101 | |||||||||||||||||
column · Unsigned32 (1..2147483647) · read-only · current An arbitrary index assigned to each board entry. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardName | 1.3.6.1.4.1.8708.2.11.2.3.1.1.2 | MgmtNameString | RO | cusfpii:1:1 | |||||||||||||||||
column · MgmtNameString · read-only · current The name of the board, for example 'tpmr2500:1:2' where the first number indicates in which sub-rack the board is present and the second number in which slot. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardExpectedType | 1.3.6.1.4.1.8708.2.11.2.3.1.1.3 | EquipmentBoardType | RC | 158 | |||||||||||||||||
column · EquipmentBoardType · read-create · current The expected board type. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardActualType | 1.3.6.1.4.1.8708.2.11.2.3.1.1.4 | EquipmentBoardType | RO | 158 | |||||||||||||||||
column · EquipmentBoardType · read-only · current The actual board type. If an unexpected board has been detected this variable can be used to see what type of board has been detected. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardDescr | 1.3.6.1.4.1.8708.2.11.2.3.1.1.5 | DisplayString | RW | | |||||||||||||||||
column · DisplayString · read-write · current User configurable label. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardSubrack | 1.3.6.1.4.1.8708.2.11.2.3.1.1.6 | SubrackNumber | RC | 1 | |||||||||||||||||
column · SubrackNumber · read-create · current The number of the subrack where the board is located. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardSlot | 1.3.6.1.4.1.8708.2.11.2.3.1.1.7 | SlotNumber | RC | 1 | |||||||||||||||||
column · SlotNumber · read-create · current The slot where the board is located. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardTemp | 1.3.6.1.4.1.8708.2.11.2.3.1.1.8 | Integer32 (-1000..1000) | RO | 357 | |||||||||||||||||
column · Integer32 (-1000..1000) · read-only · current The temperature on the board in 0.1 degrees centigrade. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardInvPhysIndexOrZero | 1.3.6.1.4.1.8708.2.11.2.3.1.1.9 | Unsigned32 (0..2147483647) | RO | 101000000 | |||||||||||||||||
column · Unsigned32 (0..2147483647) · read-only · current The row in the invPhysTable for this board. Set to 0 if not known. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardLedTest | 1.3.6.1.4.1.8708.2.11.2.3.1.1.10 | INTEGER | RW | off(1) | |||||||||||||||||
column · INTEGER · read-write · current LED test for the board. off - Normal operation. on - Light all leds.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardAdminStatus | 1.3.6.1.4.1.8708.2.11.2.3.1.1.11 | BoardOrInterfaceAdminStatus | RW | 3 | |||||||||||||||||
column · BoardOrInterfaceAdminStatus · read-write · current The administrative state of the board. down - The board should be inactive. Alarms are suppressed. service - The board is activated but alarms are suppressed. Intended for use during service or re-configuration. When service is concluded adminStatus should be set to 'up' again. up - The board should be activated when it becomes available. Alarms are not suppressed. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardOperStatus | 1.3.6.1.4.1.8708.2.11.2.3.1.1.12 | BoardOrInterfaceOperStatus | RO | 3 | |||||||||||||||||
column · BoardOrInterfaceOperStatus · read-only · current The operational state of the board. notPresent - The board is not available. down - The board remains in the 'down'-state when adminStatus is set to 'down' or if there is a fault preventing it from going to the 'up'-state. up - The board is operational. The operational state becomes 'up' when adminStatus is set to 'up' unless there are faults detected. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardLastChangeTime | 1.3.6.1.4.1.8708.2.11.2.3.1.1.13 | DateAndTime | RO | 07:e4:02:19:00:39:33:00:2b:01:00 | |||||||||||||||||
column · DateAndTime · read-only · current The time when the operational state of the board entry was last changed. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardRowStatus | 1.3.6.1.4.1.8708.2.11.2.3.1.1.14 | RowStatus | RC | 1 | |||||||||||||||||
column · RowStatus · read-create · current SNMP administrivia. Manages creation and deletion of conceptual rows. See also SNMPv2-TC. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardMissing | 1.3.6.1.4.1.8708.2.11.2.3.1.1.15 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current There is no board present in a slot where the expected board type is defined. Suppressed if administrative status is down. A(ctivation): Card out of place (COP) indication active for more than 2 seconds. D(e-activation): Card out of place (COP) indication inactive for more than 2 seconds. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardUnexpectedType | 1.3.6.1.4.1.8708.2.11.2.3.1.1.16 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current A type of board not matching the expected type is present and active in the same slot. Since the default value for the type is 'undefined' this alarm is raised when inserting an unconfigured board. A: A board with type different from the expected type is present in the slot (even if the board is not activated). D: The type matches the expected or no board is present. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardTempHighExceeded | 1.3.6.1.4.1.8708.2.11.2.3.1.1.17 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degrees centigrade below the associated threshold. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardCommunicationFailure | 1.3.6.1.4.1.8708.2.11.2.3.1.1.18 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current Communication between the control unit and the the board has failed completely. A: There is a board present but there has been no communication established within 20 seconds. D: Communication is established. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardInterworkFailed | 1.3.6.1.4.1.8708.2.11.2.3.1.1.19 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current Communication between the control unit and the board has failed due to incompatible software. A: The control unit and the board have in-compatible software. D: The control unit and the board have compatible software. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardSecondaryPowerFailed | 1.3.6.1.4.1.8708.2.11.2.3.1.1.20 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current Secondary DC power (1.8 or 2.5 V) failure. A: The secondary DC power on the board has failed. D: The secondary DC power is present. Note: If primary power fails a 'communicationFailure' alarm will most likely be raised instead. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardVitalDataMissing | 1.3.6.1.4.1.8708.2.11.2.3.1.1.21 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current Product data vital for the safe operation of the equipment is missing. A: Product data missing. D: Product data present. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardNonVitalDataMissing | 1.3.6.1.4.1.8708.2.11.2.3.1.1.22 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current Administrative product data is missing. A: Product data missing. D: Product data present. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardUnderMaintenance | 1.3.6.1.4.1.8708.2.11.2.3.1.1.23 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The board is undergoing maintenance, adminStatus is set to service. A: AdminStatus is set to service. D: AdminStatus is set to another value. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardTempThreshold | 1.3.6.1.4.1.8708.2.11.2.3.1.1.24 | Integer32 (0..800) | RW | 700 | |||||||||||||||||
column · Integer32 (0..800) · read-write · current The threshold for temperature alarm on the board in 0.1 degrees centigrade. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardSwVersionMismatch | 1.3.6.1.4.1.8708.2.11.2.3.1.1.25 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The version of the board SW does not match the SW version running och the main CU. For versions to match, the release number, e.g. 'r2b', must be the same. The build number is not required to be the same. Examples: r2b-2 matches r2b-1, r2b-2, ..., r2b-<n> r2b-<n> does NOT match r2a-<m> A: The board is started with as SW version other than the main CU. D: The board, or main CU, is restarted with matching SW versions. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardObjectProperty | 1.3.6.1.4.1.8708.2.11.2.3.1.1.26 | ObjectProperty | RO | 568328305 | |||||||||||||||||
column · ObjectProperty · read-only · current Property mask. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardTempLow | 1.3.6.1.4.1.8708.2.11.2.3.1.1.27 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The low threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated low threshold. D: Temperature is 0.5 degrees centigrade above the associated threshold. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardTempVeryHigh | 1.3.6.1.4.1.8708.2.11.2.3.1.1.28 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The very high threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degrees centigrade below the associated threshold. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardReconfigure | 1.3.6.1.4.1.8708.2.11.2.3.1.1.29 | CommandString | RO | ||||||||||||||||||
column · CommandString · read-only · current Applicable for cu, cu2osc, cuSfp, cuSfpii and voa8chii. Reconfigure cu or cu2osc board to cuSfp. Reconfigure cu2osc or cuSfp board to cuSfpii. Reconfigure older CU-board to cuSfpiii. Reconfigure voa8chii to voa8chsfp. Reconfigure tpq10Gfec to tpq10gfeci or vise versa Reconfigure tpq10GfecReg to tpq10gfecregi or vise versa | |||||||||||||||||||||
| CequipmentBoardLedStatus | 1.3.6.1.4.1.8708.2.11.2.3.1.1.30 | INTEGER | RO | clear(1) | |||||||||||||||||
column · INTEGER · read-only · current LED status for the board. This is primarily intended for debugging
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardModuleInfo | 1.3.6.1.4.1.8708.2.11.2.3.1.1.31 | DisplayString | RO | | |||||||||||||||||
column · DisplayString · read-only · current Information (for example firmware and serial number) about the module. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardNewSwActivatedButNotRestarted | 1.3.6.1.4.1.8708.2.11.2.3.1.1.32 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current A new SW version on the board has been activated, but the board has not been rebooted. This means that after the next reboot, a new SW will be active. For the main CU, this also means that the backup will be read from a new directory. A: A new SW has been activated but the board has not been rebooted within 12 hours. D: The board is rebooted or the SW is reverted. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardLowTemperature | 1.3.6.1.4.1.8708.2.11.2.3.1.1.33 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The environmental temperature on the board is below startuptemperature (+3 centigrade). A: The temperature is below +3 degrees centigrade. D: Temperature has increased to +5 degrees centigrade. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardTempLowThreshold | 1.3.6.1.4.1.8708.2.11.2.3.1.1.34 | Integer32 (-400..400) | RO | 30 | |||||||||||||||||
column · Integer32 (-400..400) · read-only · current The threshold for low temperature alarm on the board in 0.1 degrees centigrade. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardAdditionalInfo | 1.3.6.1.4.1.8708.2.11.2.3.1.1.35 | DisplayString | RO | | |||||||||||||||||
column · DisplayString · read-only · current Additional information about the board, e.g. FPGA revision. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardBootError | 1.3.6.1.4.1.8708.2.11.2.3.1.1.36 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The card fails to boot. A: The card fails to boot. D: The card boot successfully. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardHardwareError | 1.3.6.1.4.1.8708.2.11.2.3.1.1.37 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current A hardware error occured. A: A hardware error occured. D: No hardware error. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardLowDiskSpace | 1.3.6.1.4.1.8708.2.11.2.3.1.1.38 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current Low disk space in the board. A: Not enough disk space. D: Disk space is enough. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardClockDrift | 1.3.6.1.4.1.8708.2.11.2.3.1.1.39 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current Clock frequency is out of range. A: Clock frequency out is out of range. D: Clock frequency is in range. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardPostponeFwUpgrade | 1.3.6.1.4.1.8708.2.11.2.3.1.1.40 | INTEGER | RW | disabled(1) | |||||||||||||||||
column · INTEGER · read-write · current Postpone activation of new traffic firmware when the board software is upgraded next time. If no firmware changes are available when upgrading this option will not have any effect.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardActivatePendingFwCommand | 1.3.6.1.4.1.8708.2.11.2.3.1.1.41 | CommandString | RO | ||||||||||||||||||
column · CommandString · read-only · current Command to activate a pending firmware upgrade. | |||||||||||||||||||||
| CequipmentBoardFwActivationPending | 1.3.6.1.4.1.8708.2.11.2.3.1.1.42 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current Firmware activation has been postponed in a previous software upgrade. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardFeatureNotSupported | 1.3.6.1.4.1.8708.2.11.2.3.1.1.43 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current A configuration request has failed since the chosen feature is not supported by the active firmware. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardFwReloadNeeded | 1.3.6.1.4.1.8708.2.11.2.3.1.1.44 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The traffic HW has been programmed by a version of the system that does not offer a supported upgrade path to the currently running version. This typically happens after a downgrade or rollback of the SW. The state of the traffic HW is formally unknown and further changes to the traffic configuration cannot be guaranteed. A reset of the traffic unit is recommended. This will cause a short traffic hit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardFwContextUnknown | 1.3.6.1.4.1.8708.2.11.2.3.1.1.45 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The running version of the SW cannot recover the settings of the traffic HW/FW. The state of the traffic HW is unknown. A reset of the traffic unit is recommended. This will cause a short traffic hit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardBoardVariant | 1.3.6.1.4.1.8708.2.11.2.3.1.1.46 | INTEGER | RW | notApplicable(2147483647) | |||||||||||||||||
column · INTEGER · read-write · current Determines board configuration. dualMuxponderProt - 2x Muxponder with protection hexTransponder - 6x Transponder tripleMuxponderProt - 3x Muxponder with protection quadTransponderProt - 4x Transponder with protection notApplicable - 2147483647 is used to indicate that the attribute is not used on the board.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardCabinetConnectivity | 1.3.6.1.4.1.8708.2.11.2.3.1.1.47 | INTEGER | RW | disabled(1) | |||||||||||||||||
column · INTEGER · read-write · current Monitor Cabinet status if enabled. Alarm is raised if connection is lost.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardCabinetConnectionFailure | 1.3.6.1.4.1.8708.2.11.2.3.1.1.48 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current Connection to the cabinet has failed. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardOperationalVariant | 1.3.6.1.4.1.8708.2.11.2.3.1.1.49 | INTEGER | RC | normal(1) | |||||||||||||||||
column · INTEGER · read-create · current Operational Variant mode of board, Normal or OpenFlow Controlled.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardAid | 1.3.6.1.4.1.8708.2.11.2.3.1.1.50 | DisplayString | RO | BRD-1-1 | |||||||||||||||||
column · DisplayString · read-only · current The access identifier (AID) of the product. The format is according to GR-833. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentBoardPhysicalLocation | 1.3.6.1.4.1.8708.2.11.2.3.1.1.51 | DisplayString | RO | BRD-1-1 | |||||||||||||||||
column · DisplayString · read-only · current The Physical location of the product. The format is according to GR-833. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NequipmentPowerList | 1.3.6.1.4.1.8708.2.11.2.4 | ||||||||||||||||||||
| TequipmentPowerTable | 1.3.6.1.4.1.8708.2.11.2.4.1 | NA | |||||||||||||||||||
table · not-accessible · current The list of power supplies. | |||||||||||||||||||||
| RequipmentPowerEntry | 1.3.6.1.4.1.8708.2.11.2.4.1.1 | NA | |||||||||||||||||||
| CequipmentPowerIndex | 1.3.6.1.4.1.8708.2.11.2.4.1.1.1 | Unsigned32 (1..2147483647) | RO | 1011 | |||||||||||||||||
column · Unsigned32 (1..2147483647) · read-only · current An arbitrary index assigned to each power module. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerName | 1.3.6.1.4.1.8708.2.11.2.4.1.1.2 | DisplayString (SIZE (0..255)) | RO | pow:1:1 | |||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-only · current The name of the power module. For example 'pow:1:2'. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerSubrack | 1.3.6.1.4.1.8708.2.11.2.4.1.1.3 | SubrackNumber | RO | 1 | |||||||||||||||||
column · SubrackNumber · read-only · current The number of the subrack in which the power module is present. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerSlot | 1.3.6.1.4.1.8708.2.11.2.4.1.1.4 | Unsigned32 (1..2) | RO | 1 | |||||||||||||||||
column · Unsigned32 (1..2) · read-only · current The number of the slot in which the power module is present. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerType | 1.3.6.1.4.1.8708.2.11.2.4.1.1.5 | INTEGER | RO | dc(2) | |||||||||||||||||
column · INTEGER · read-only · current The the type of power module. ac - AC power supply (230V). dc - DC power supply (48V).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerInvPhysIndexOrZero | 1.3.6.1.4.1.8708.2.11.2.4.1.1.9 | Unsigned32 (0..2147483647) | RO | 151000000 | |||||||||||||||||
column · Unsigned32 (0..2147483647) · read-only · current The row in the invPhysTable for this power module. Set to 0 if not known. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerAdminStatus | 1.3.6.1.4.1.8708.2.11.2.4.1.1.10 | INTEGER | RW | up(2) | |||||||||||||||||
column · INTEGER · read-write · current The administrative state of the power module. down - This power module is not monitored. Suppresses alarms. up - The power module is monitored.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerOperStatus | 1.3.6.1.4.1.8708.2.11.2.4.1.1.11 | INTEGER | RO | up(3) | |||||||||||||||||
column · INTEGER · read-only · current The operational state of the power module. notPresent - The power module is not present. down - The module is not active or there are faults preventing it from going to the 'up'-state. up - The module is operational.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerRowStatus | 1.3.6.1.4.1.8708.2.11.2.4.1.1.12 | RowStatus | RW | ||||||||||||||||||
column · RowStatus · read-write · current Manages creation and deletion of conceptual rows. See also SNMPv2-TC. | |||||||||||||||||||||
| CequipmentPowerACPowerFailed | 1.3.6.1.4.1.8708.2.11.2.4.1.1.13 | FaultStatus | RO | obsolete | |||||||||||||||||
column · FaultStatus · read-only · obsolete AC power supply failed (230 V). A(ctivation): Active HW indication. D(e-activation): Inactive HW indication. | |||||||||||||||||||||
| CequipmentPowerDCPowerFailed | 1.3.6.1.4.1.8708.2.11.2.4.1.1.14 | FaultStatus | RO | obsolete | |||||||||||||||||
column · FaultStatus · read-only · obsolete DC power supply failed (48 V). A: Active HW indication. D: Inactive HW indication. | |||||||||||||||||||||
| CequipmentPowerTemperatureHigh | 1.3.6.1.4.1.8708.2.11.2.4.1.1.15 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The built-in temperature monitoring of the power module thinks it is too hot. A: Active HW indication. D: Inactive HW indication. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerModuleMissing | 1.3.6.1.4.1.8708.2.11.2.4.1.1.16 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The power module is not available. A: Active HW indication. D: Inactive HW indication. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerObjectProperty | 1.3.6.1.4.1.8708.2.11.2.4.1.1.17 | ObjectProperty | RO | 0 | |||||||||||||||||
column · ObjectProperty · read-only · current Property mask. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerDCPowerFailedSeverity | 1.3.6.1.4.1.8708.2.11.2.4.1.1.18 | AlarmPerceivedSeverity | RW | 4 | |||||||||||||||||
column · AlarmPerceivedSeverity · read-write · current The severity of DC Power failed alarm. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerAid | 1.3.6.1.4.1.8708.2.11.2.4.1.1.19 | DisplayString | RO | POW-1-1 | |||||||||||||||||
column · DisplayString · read-only · current The access identifier (AID) of the product. The format is according to GR-833. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerPhysicalLocation | 1.3.6.1.4.1.8708.2.11.2.4.1.1.20 | DisplayString | RO | POW-1-1 | |||||||||||||||||
column · DisplayString · read-only · current The Physical location of the product. The format is according to GR-833. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentPowerPowerFailed | 1.3.6.1.4.1.8708.2.11.2.4.1.1.21 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current Power supply failed. A: Active HW indication. D: Inactive HW indication. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NequipmentFanList | 1.3.6.1.4.1.8708.2.11.2.5 | ||||||||||||||||||||
| TequipmentFanTable | 1.3.6.1.4.1.8708.2.11.2.5.1 | NA | |||||||||||||||||||
table · not-accessible · current The list of fan modules. | |||||||||||||||||||||
| RequipmentFanEntry | 1.3.6.1.4.1.8708.2.11.2.5.1.1 | NA | |||||||||||||||||||
| CequipmentFanIndex | 1.3.6.1.4.1.8708.2.11.2.5.1.1.1 | Unsigned32 (1..2147483647) | RO | 1011 | |||||||||||||||||
column · Unsigned32 (1..2147483647) · read-only · current An arbitrary index assigned to each fan module. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentFanName | 1.3.6.1.4.1.8708.2.11.2.5.1.1.2 | DisplayString (SIZE (0..255)) | RO | fan:1:1 | |||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-only · current The name of the fan module. For example 'fan:1:2', where the first number indicates the subrack and the second number the fan slot. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentFanSubrack | 1.3.6.1.4.1.8708.2.11.2.5.1.1.3 | SubrackNumber | RO | 1 | |||||||||||||||||
column · SubrackNumber · read-only · current The number of the subrack in which the fan module is present. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentFanSlot | 1.3.6.1.4.1.8708.2.11.2.5.1.1.4 | Unsigned32 (1..3) | RO | 1 | |||||||||||||||||
column · Unsigned32 (1..3) · read-only · current The number of the fan-slot in which the fan module is present. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentFanInvPhysIndexOrZero | 1.3.6.1.4.1.8708.2.11.2.5.1.1.5 | Unsigned32 (0..2147483647) | RO | 153000000 | |||||||||||||||||
column · Unsigned32 (0..2147483647) · read-only · current The row in the invPhysTable for this fan module. Set to 0 if not known. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentFanAdminStatus | 1.3.6.1.4.1.8708.2.11.2.5.1.1.6 | INTEGER | RW | up(2) | |||||||||||||||||
column · INTEGER · read-write · current The administrative state of the fan module. down - This fan module should not be monitored. Suppresses alarms. Useful if a subrack has only one fan for some reason. up - The fan module should be monitored.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentFanOperStatus | 1.3.6.1.4.1.8708.2.11.2.5.1.1.7 | INTEGER | RO | up(3) | |||||||||||||||||
column · INTEGER · read-only · current The operational state of the fan module. Note: It is not possible to distinguish between a missing fan and a failed fan. Therefore 'notPresent' is currently not used. down - The fan module is not de-activated or not present or there are faults preventing it from going to the 'up'-state. up - The fan module is active and monitored.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentFanRowStatus | 1.3.6.1.4.1.8708.2.11.2.5.1.1.8 | RowStatus | RW | ||||||||||||||||||
column · RowStatus · read-write · current Manages creation and deletion of conceptual rows. See also SNMPv2-TC. | |||||||||||||||||||||
| CequipmentFanUnitFailed | 1.3.6.1.4.1.8708.2.11.2.5.1.1.9 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The fan module has failed or is absent. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentFanMainUnitFailed | 1.3.6.1.4.1.8708.2.11.2.5.1.1.10 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The main fan module has failed or is absent. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentFanObjectProperty | 1.3.6.1.4.1.8708.2.11.2.5.1.1.11 | ObjectProperty | RO | 0 | |||||||||||||||||
column · ObjectProperty · read-only · current Property mask. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentFanFanFault | 1.3.6.1.4.1.8708.2.11.2.5.1.1.12 | FaultStatus | RO | 1 | |||||||||||||||||
column · FaultStatus · read-only · current The Fan malfunction or fan speed differs from the set speed. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentFanAid | 1.3.6.1.4.1.8708.2.11.2.5.1.1.13 | DisplayString | RO | FAN-1-1 | |||||||||||||||||
column · DisplayString · read-only · current The access identifier (AID) of the product. The format is according to GR-833. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CequipmentFanPhysicalLocation | 1.3.6.1.4.1.8708.2.11.2.5.1.1.14 | DisplayString | RO | FAN-1-1 | |||||||||||||||||
column · DisplayString · read-only · current The Physical location of the product. The format is according to GR-833. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NlumentisEquipmentNotifications | 1.3.6.1.4.1.8708.2.11.2.6 | ||||||||||||||||||||
| NequipmentNotifyPrefix | 1.3.6.1.4.1.8708.2.11.2.6.0 | ||||||||||||||||||||
| !equipmentBoardRowStatusActive | 1.3.6.1.4.1.8708.2.11.2.6.0.1 | ||||||||||||||||||||
notification · current Sent when a board is added to the configuration. | |||||||||||||||||||||
| !equipmentBoardRowStatusDestroy | 1.3.6.1.4.1.8708.2.11.2.6.0.2 | deprecated | |||||||||||||||||||
notification · deprecated Sent when a board is removed from the configuration. | |||||||||||||||||||||
| !equipmentBoardRowStatusInserted | 1.3.6.1.4.1.8708.2.11.2.6.0.3 | ||||||||||||||||||||
notification · current Sent when a board is physically inserted. | |||||||||||||||||||||
| !equipmentBoardRowStatusRemoved | 1.3.6.1.4.1.8708.2.11.2.6.0.4 | ||||||||||||||||||||
notification · current Sent when a board is physically removed. | |||||||||||||||||||||
| !equipmentBoardRowStatusDeleted | 1.3.6.1.4.1.8708.2.11.2.6.0.5 | ||||||||||||||||||||
notification · current Sent when a board is deleted from the configuration. | |||||||||||||||||||||
| NequipmentNode | 1.3.6.1.4.1.8708.2.11.2.7 | ||||||||||||||||||||
| SequipmentNodeLedTest | 1.3.6.1.4.1.8708.2.11.2.7.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current LED test for the network element. off - Normal operation. on - Light all leds.
| |||||||||||||||||||||
| SequipmentNodeIcnRedundancyMode | 1.3.6.1.4.1.8708.2.11.2.7.2 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Indicates whether the internal communication network between sub-racks, ICN3 and ICN4, can be connected in a redundant manner or not. disabled - Non-redundant ICN connection. Both ICN ports are enable for forwarding. Note: Connecting both ICN ports to the same internal switch will cause a loop. ring - Redundant ICN connection. Only one ICN port at a time is enabled for forwarding even if both are physically connected and both links are up. Note: The port that is first connected will be used for forwarding and if disconnected, the other port will be enabled automatically. disabled - Non-redundant connection. ring - Redundantly connected in a ring.
| |||||||||||||||||||||
| SequipmentNodeMemoryProfile | 1.3.6.1.4.1.8708.2.11.2.7.3 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Indicates whether memory profilation shall be done or not. disabled - No memory profile enabled - Memory profile done
| |||||||||||||||||||||
| SequipmentAllowDummyPassiveSlots | 1.3.6.1.4.1.8708.2.11.2.7.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This option is applicable for TM-3000
subracks only.
Normally passive boards can only be created in
slots 13-22. Enabling this options allows the
user to create full-size passive board objects
in slot 2-12 as well.
Note, however, that supervision of board presence
and reading of board inventory is NOT possible
in slot 2-12.
Also note that half-size boards, like ad1AB, are
not allowed in slots 2-12.
disabled - Passive boards NOT allowed in slots 2-12.
enabled - Allow full-size passive boards objects
in slot 2-12.
| |||||||||||||||||||||
| SequipmentNodeManagementVlan | 1.3.6.1.4.1.8708.2.11.2.7.5 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Indicates if VLAN is available (via DCN for nodes with cu) or not. off - No bridging of VLAN. (mgmtVlan off in node) bridge2dcn - VLAN is bridged to DCN. (mgmtVlan on in node, used for cu) on - mgmtVlan is on, used for culess
| |||||||||||||||||||||
| SequipmentNodeMgmtVlanPrivacy | 1.3.6.1.4.1.8708.2.11.2.7.6 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Set Mgmt Vlan privacy. Setting is for main subrack in node. Boards affected (in R14.0) is gbeMxp10GFEC, msMxp10G, gbe10Emxp10G and gbe22Emxp10G. isolated - privacy enabled. Not possible to communicate between boards nor ports. In slave subrack setting is only on ports, not boards community - privacy disabled. It is possible to communicate between both boards and ports.
| |||||||||||||||||||||
| SequipmentNodeDcnRedundancyMode | 1.3.6.1.4.1.8708.2.11.2.7.7 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Indicates whether the DCN ports on a CU, DCN1 and DCN2, can be connected in a redundant manner or not. disabled - Non-redundant DCN connection. Both DCN ports are enable for forwarding. Note: Connecting both DCN ports to the same ethernet switch will cause a loop. enabled - Redundant DCN connection. Only one DCN port at a time is enabled for forwarding even if both are physically connected and both links are up. Note: The port that is first connected will be used for forwarding and if disconnected, the other port will be enabled automatically. disabled - Non-redundant connection. enabled - Redundantly connected through a hub.
| |||||||||||||||||||||
| SequipmentNodeProxyArp | 1.3.6.1.4.1.8708.2.11.2.7.8 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Indicates if the Proxy ARP functionality is used. Using Proxy ARP simplifies the IP-address allocation and minimizes the use of different subnets in the network. disabled - Proxy ARP function disabled. The nodes must be in different subnets and PPP links use routing between the nodes. enabled - Proxy ARP function enabled. All nodes can be in the same IP-subnet and PPP links do not require routing between the nodes. The Gateway node/Gateway Network Element (GNE) act as router.
| |||||||||||||||||||||
| NequipmentResource | 1.3.6.1.4.1.8708.2.11.2.8 | ||||||||||||||||||||
| SequipmentResourceNumberOfBoards | 1.3.6.1.4.1.8708.2.11.2.8.1 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current The number of boards, active and passive, currently in use in this system | |||||||||||||||||||||
| SequipmentResourceMaxNumberOfBoards | 1.3.6.1.4.1.8708.2.11.2.8.2 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current The maximum number of boards, active and passive, that is supported by the embedded software of this system | |||||||||||||||||||||
| SequipmentResourceNumberOfActiveBoards | 1.3.6.1.4.1.8708.2.11.2.8.3 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current The number of active boards running on this system | |||||||||||||||||||||
| SequipmentResourceMaxNumberOfActiveBoards | 1.3.6.1.4.1.8708.2.11.2.8.4 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current The maximum number of active boards that is supported by the embedded software of this system. | |||||||||||||||||||||
| NequipmentSlot | 1.3.6.1.4.1.8708.2.11.2.9 | ||||||||||||||||||||
| TequipmentSlotTable | 1.3.6.1.4.1.8708.2.11.2.9.1 | NA | |||||||||||||||||||
table · not-accessible · current The slot list. | |||||||||||||||||||||
| RequipmentSlotEntry | 1.3.6.1.4.1.8708.2.11.2.9.1.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the slot list. One entry for each slot.
| |||||||||||||||||||||
| CequipmentSlotIndex | 1.3.6.1.4.1.8708.2.11.2.9.1.1.1 | Unsigned32 (1..2147483647) | RO | ||||||||||||||||||
column · Unsigned32 (1..2147483647) · read-only · current An arbitrary index assigned to each slot entry. | |||||||||||||||||||||
| CequipmentSlotName | 1.3.6.1.4.1.8708.2.11.2.9.1.1.2 | MgmtNameString | RO | ||||||||||||||||||
column · MgmtNameString · read-only · current The name of the slot, for example 'tpmr2500:1:2' where the first number indicates in which sub-rack the slot is present and the second number in which slot. | |||||||||||||||||||||
| CequipmentSlotSubrack | 1.3.6.1.4.1.8708.2.11.2.9.1.1.3 | SubrackNumber | RO | ||||||||||||||||||
column · SubrackNumber · read-only · current The number of the subrack in which the slot is present. | |||||||||||||||||||||
| CequipmentSlotSlot | 1.3.6.1.4.1.8708.2.11.2.9.1.1.4 | SlotNumber | RO | ||||||||||||||||||
column · SlotNumber · read-only · current The slot number. | |||||||||||||||||||||
| CequipmentSlotAdminStatus | 1.3.6.1.4.1.8708.2.11.2.9.1.1.5 | AdminStatus | RW | ||||||||||||||||||
column · AdminStatus · read-write · current The administrative state of the slot. down - The slot is not monitored. up - The interface should be activated. | |||||||||||||||||||||
| CequipmentSlotUsageState | 1.3.6.1.4.1.8708.2.11.2.9.1.1.6 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Tells if the slot is used or not. used - Slot is used. notUsed - Slot is not used.
| |||||||||||||||||||||
| CequipmentSlotEmptySlot | 1.3.6.1.4.1.8708.2.11.2.9.1.1.7 | FaultStatus | RO | ||||||||||||||||||
column · FaultStatus · read-only · current Slot is empty, alarm only applicable for systems with mendatory slot usage A: Slot is empty. D: No empty slot. | |||||||||||||||||||||
| CequipmentSlotEquipped | 1.3.6.1.4.1.8708.2.11.2.9.1.1.8 | TruthValueWithNA | RO | ||||||||||||||||||
column · TruthValueWithNA · read-only · current Is the entity equipped. | |||||||||||||||||||||
| CequipmentSlotAid | 1.3.6.1.4.1.8708.2.11.2.9.1.1.9 | DisplayString (SIZE (0..255)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-only · current The access identifier (AID) of the slot. The format is according to GR-833. | |||||||||||||||||||||
| CequipmentSlotPhysicalLocation | 1.3.6.1.4.1.8708.2.11.2.9.1.1.10 | DisplayString (SIZE (0..255)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-only · current The physical location of the slot. The format is according to GR-833. | |||||||||||||||||||||
| NequipmentOpticalModuleList | 1.3.6.1.4.1.8708.2.11.2.10 | ||||||||||||||||||||
| TequipmentOpticalModuleTable | 1.3.6.1.4.1.8708.2.11.2.10.1 | NA | |||||||||||||||||||
table · not-accessible · current The module list. | |||||||||||||||||||||
| RequipmentOpticalModuleEntry | 1.3.6.1.4.1.8708.2.11.2.10.1.1 | NA | |||||||||||||||||||
| CequipmentOpticalModuleIndex | 1.3.6.1.4.1.8708.2.11.2.10.1.1.1 | Unsigned32 (1..2147483647) | RO | ||||||||||||||||||
column · Unsigned32 (1..2147483647) · read-only · current An arbitrary index assigned to each entry. | |||||||||||||||||||||
| CequipmentOpticalModuleHostBoardType | 1.3.6.1.4.1.8708.2.11.2.10.1.1.2 | EquipmentBoardType | RO | ||||||||||||||||||
column · EquipmentBoardType · read-only · current The actual board type hosting the optical module. | |||||||||||||||||||||
| CequipmentOpticalModuleType | 1.3.6.1.4.1.8708.2.11.2.10.1.1.3 | MgmtNameString | RO | ||||||||||||||||||
column · MgmtNameString · read-only · current The type of optical module, for example monitor, switch, wss, amp etc | |||||||||||||||||||||
| CequipmentOpticalModuleName | 1.3.6.1.4.1.8708.2.11.2.10.1.1.4 | MgmtNameString | RO | ||||||||||||||||||
column · MgmtNameString · read-only · current The management name of the interface, for example 'module:[HostBoardType]:[ moduleType]:[subrack]:[slot]'. | |||||||||||||||||||||
| CequipmentOpticalModuleSubrack | 1.3.6.1.4.1.8708.2.11.2.10.1.1.5 | SubrackNumber | RO | ||||||||||||||||||
column · SubrackNumber · read-only · current The number of the subrack where the module is located. | |||||||||||||||||||||
| CequipmentOpticalModuleSlot | 1.3.6.1.4.1.8708.2.11.2.10.1.1.6 | SlotNumber | RO | ||||||||||||||||||
column · SlotNumber · read-only · current The number of the slot where the module is located. | |||||||||||||||||||||
| CequipmentOpticalModuleFirmwareVersion | 1.3.6.1.4.1.8708.2.11.2.10.1.1.7 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current Firmware version of the module. | |||||||||||||||||||||
| CequipmentOpticalModuleSerialNumber | 1.3.6.1.4.1.8708.2.11.2.10.1.1.8 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current Serial number of the module. | |||||||||||||||||||||
| CequipmentOpticalModuleWarmingUpState | 1.3.6.1.4.1.8708.2.11.2.10.1.1.9 | TruthValueWithNA | RO | ||||||||||||||||||
column · TruthValueWithNA · read-only · current Module is warming up, the optics has not reached a stable state. True: Module is warming up. False: Module is ready and optics have reached stable state. | |||||||||||||||||||||
| CequipmentOpticalModuleFailure | 1.3.6.1.4.1.8708.2.11.2.10.1.1.10 | FaultStatus | RO | ||||||||||||||||||
column · FaultStatus · read-only · current The module is experiencing a failure. A(ctivation): The module has failed D(e-activation): The module is OK again | |||||||||||||||||||||
Textual conventions
EquipmentBoardTypeINTEGERacd10G(10002)acd2pGbE(10000)acd5pGbE(10001)ad1AB(7)ad1BA(8)ad1c2fotdr(273)ad1cwdm(42)ad1cwdm2F(78)ad1dwdm2F(77)ad1spr(23)ad2AB(9)ad2BA(10)ad2cwdm(43)ad2oaAB(19)ad2oaBA(20)ad2x1cwdm(56)ad2x2cwdm(57)ad4AB(11)ad4BA(12)ad4Even50(140)ad4Odd50(141)ad4dwdm2F(85)adcwdm(22)bsu1x5Even(130)bsu1x5Odd(131)co10(286)co2xOTDR1611(291)co4(228)co5(229)coD40ev(159)coD40eve(160)coD40od(161)coD40ode(162)coD48ev(281)coD48od(282)coD4919(292)coD4923(293)coD4927(294)coD4931(295)coD4935(296)coD4939(297)coD4943(298)coD4947(299)coD4951(300)coD4955(301)coD919926(218)coD919926e(223)coD927934(219)coD927934e(224)coD935942(220)coD935942e(225)coD943950(221)coD943950e(226)coD951958(222)coD951958e(227)codsf20eva(230)codsf20evb(231)codsf24mpo10104(279)codsf2919(242)codsf2922(243)codsf2923(244)codsf2926(245)codsf2927(246)codsf2930(247)codsf2931(248)codsf2934(249)codsf2935(250)codsf2938(251)codsf2939(252)codsf2942(253)codsf2943(254)codsf2946(255)codsf2947(256)codsf2950(257)codsf2951(258)codsf2954(259)codsf2955(260)codsf2958(261)codsf4919(232)codsf4926(233)codsf4927(234)codsf4934(235)codsf4935(236)codsf4942(237)codsf4943(238)codsf4950(239)codsf4951(240)codsf4958(241)compo24(216)coocuD4x4(288)coocuD4x8(289)cooiuc50100(290)cu(1)cu1osc(26)cu2osc(27)cuSfp(88)cuSfpii(158)cuSfpiii(200)dQgbeMxpR(118)dcDk652km100(207)dcDk652km120(208)dcDk652km20(163)dcDk652km40(164)dcDk652km60(165)dcDk652km80(166)dcP652km100(170)dcP652km120(171)dcP652km20(209)dcP652km40(167)dcP652km60(168)dcP652km80(169)du2F8C(62)edu10GLT(10004)edu10GLTS(10005)edu12pGbE(115)edu5GT(10003)edu6pGbE(96)emxp120iie(181)emxp1u(266)emxp1us(267)emxp220iie(196)emxp240iie(201)emxp3(206)emxp40Gii(172)emxp440(269)emxp440q(283)emxp48iie(194)emxp62iie(180)emxp800xh(287)emxp80Gii(142)escon8(46)fha1u1(211)fhau1(210)fhmxp10g(198)fpu1(203)fpuOas2824(60)fpuYm235(84)fxp400gotn(215)gbe10Emxp10G(114)gbe10Emxp10Gii(132)gbe22Emxp10G(121)gbe22Emxp10Gii(129)gbe9Mxp10G(76)gbeMxp10GFEC(116)gxp10G(51)gxp2500(49)gxp2500Sfp(50)hdea1600(274)mROADM1P800(95)mba1(133)mba1SonetDeprecated(134)mba2(135)mba2E(146)mba2EptpSdh(149)mba2EptpSonet(150)mba2SonetDeprecated(136)mba2ptpSdh(147)mba2ptpSonet(148)mdu16cl50g(175)mdu40Even(104)mdu40EvenL(151)mdu40Odd(105)mdu40OddL(152)mdu4Ext2F(79)mdu4ExtAB(92)mdu4ExtBA(93)mdu4Term2F(80)mdu4TermAB(40)mdu4TermBA(41)mdu8Ee(106)mdu8Eo(107)mdu8EvenExt(69)mdu8EvenTerm(70)mdu8Ext(15)mdu8Term(16)mdu8Term2(58)msMxp(109)msMxp10G(127)msMxp10GTCEr(126)msMxp40G(178)msMxpDQgbe(112)msMxpQMS2G5(128)msMxpQMS2G5R(143)msMxpR(111)msTp40G(177)mu2F8C(61)mxp004(18)mxp028(6)mxp100gotn(199)mxp10gotn(179)mxp16(31)mxp200gotn(268)mxp4x2G5(98)mxp4x2G5Oc(124)mxp8(30)mxp8iiSdh(144)mxp8iiSonet(145)mxpmbh1Sdh(137)mxpmbh1Sonet(138)nidGE(20000)nidSfp155(20001)nidSfp2488(20004)nidSfp622(20002)nidSfpVc12(20003)oa(14)oa1x15dBm(47)oa1x17dBm(75)oa1x20dBm(82)oa1x20dBmVg(153)oa1x20dBmVg2(212)oa1x20dBmVgb(277)oa1x21dBmVgEC(284)oa1x26dBm(122)oa1xFG10dBm(101)oa1xLG20dBm(99)oa1xLG20dBmb(275)oa2(21)oa2x15dBm(48)oa2x17dBm(72)oa2x20dBm(83)oa2x20dBmVg(154)oa2x20dBmVg2(213)oa2x20dBmVgb(278)oa2x21dBmVgEC(285)oa2x21seed(189)oa2xFG10dBm(102)oa2xLG20dBm(100)oa2xLG20dBmb(276)oadm2ch(265)oapow1x17dBm(74)oapre1x17dBm(71)oar450c(87)oaraed20lghyb(270)oaraed21hghyb(204)oaraed21hgind(205)obu(28)ocm2p(108)ocm8p(272)ocu2(5)ocu4(17)ocudq(182)ocuseed2p(188)oiuc100200(73)oiuc50100(94)otdr8p(280)oxc16(4)oxc8(3)oypatchcord(190)pcu2p(123)ptio100g(264)ptio10g(214)rfu1(217)roadm1x2G100(155)roadm1x2G50(156)roadm1x4G100(117)roadm1x4f(263)roadm1x8G50(139)roadm1x9f(271)sync2Mhz(29)tgCad86XX02(1056)tgCad86XX04(1055)tgCo10(1010)tgCo11(1011)tgCo12(1012)tgCo14(1014)tgCo15(1015)tgCo16(1016)tgCo4(1001)tgCo5(1005)tgCo6(1006)tgCo7(1007)tgCo8(1008)tgCo9(1009)tgCoBSU1x5ev(1050)tgCoBSU1x5od(1051)tgCoD40ev(1041)tgCoD40eve(1042)tgCoD40od(1043)tgCoD40ode(1044)tgCoD4XXX(1070)tgCoDSF20(1080)tgCoDSF20evA(1081)tgCoDSF20evB(1082)tgCoDSF20odA(1083)tgCoDSF20odB(1084)tgCoDSF2ch9XXAB(1057)tgCoDSF2ch9XXBA(1059)tgCoDSF4ch9XXAB(1058)tgCoDSF4ch9XXBA(1060)tgCoDxxxyyy(1040)tgCoSFBSU1x5ev(1085)tgTco12(2012)tgTco14(2014)tgTcosf2x1b(1061)tgTcosf2x1d(1062)tm100mxp(185)tm100reg(187)tm100tp(186)tm206AddDrop(9870101)tm206Cu(9600201)tm206Cu2(9600202)tm206Fan(9200201)tm206MuxDemux4ch1t4(9813001)tm206MuxDemux4ch5t8(9814001)tm206MuxDemux4chBidir1(9823001)tm206MuxDemux4chBidir2(9823002)tm206MuxDemux4p1ch1t4(9813101)tm206MuxDemux4p1ch5t8(9814101)tm206OSC1(9221001)tm206OSC2(9221002)tm206TAM4xesc(9500101)tm206TAMln2xfc(9510401)tm206TAMln4xesc(9510101)tm206TAMln4xetr(9510201)tm206TAMlnFlex(9510301)tm206TAMlnp2xfc(9510501)tm206tp2x4gfc(9780001)tm4011(184)tm4700(183)tp100gotn(195)tp100gotnii(262)tp10G(24)tp10GBu(65)tp10GClBu(67)tp10GClTc(97)tp10GLAN(44)tp10GLANBu(66)tp10GLANClBu(68)tp10GOtnTc(103)tp10GRC(45)tp10GTcEr(113)tpD10GL(63)tpD10GbE(90)tpD10GbER(91)tpDDGbE(59)tpDDGbER(64)tpDFcC(35)tpDFcD(34)tpDFcDv2(54)tpDFcSfp(55)tpDGbE(13)tpDGbEC(33)tpDGbED(32)tpDGbEDv2(52)tpDGbESfp(53)tpFcGbEC(37)tpFcGbED(36)tpLMr2500(25)tpMr2500(2)tpMr25v2(89)tpQMS(119)tpQMSR(120)tpQMr(39)tpQMri(86)tpTFcD(38)tphex10gotn(193)tpmrHL16G(197)tpmrHL16GUni(202)tpq10Gfec(157)tpq10GfecReg(174)tpq10gfeci(191)tpq10gfecregi(192)tpqmp(173)ts1100AddDrop(870101)ts1100AddDropDouble(850100)ts1100AddDropSingle(870102)ts1100AttenuatorDouble(270001)ts1100Conv1250Cwdm(750000)ts1100Conv2500Cwdm(760000)ts1100DWDMMuxDemux(883101)ts1100DWDMMuxDemuxExt(883001)ts1100Duplexer(812001)ts1100DuplexerDouble(802001)ts1100EthMux4p(220401)ts1100MuxDemux4ch1t4(813001)ts1100MuxDemux4ch5t8(814001)ts1100MuxDemux4chBidir(823000)ts1100MuxDemux4chExtPizza(803100)ts1100MuxDemux4chPizza(803000)ts1100MuxDemux4p1ch1t4(813101)ts1100MuxDemux4p1ch5t8(814101)ts1100MuxDemux8ch(813200)ts1100MuxDemux8ch2(813400)ts1100MuxDemux8chExtPizza(803300)ts1100MuxDemux8chPizza(803200)ts1100MuxDemux8p1ch(813300)ts1100Muxponder10G(590000)ts1100Muxponder10G2(5900002)ts1100Nmb(600100)ts1100Nmb6003(600300)ts1100OPU(250101)ts1100OPUDouble(250201)ts1100Power9000Supply(900000)ts1100Power9048Supply(904800)ts1100Power9122Supply(912200)ts1100Power9148Supply(914800)ts1100Power9220Supply(922000)ts1100PreAmp(261001)ts1100PreAmpDouble(260401)ts1100Tp10G(790000)ts1100Tp10G7910(791000)ts1100Tp10G7910Rep(7910002)ts1100Tp2500Cwdm1(770000)ts1100Tp2x2500Cwdm1(772000)ts1100Tp2x4GFC(740001)ts1100UnivAgg(550000)ts1100UnivAgg2xDGbE(5800002)ts1100UnivAgg2xGbE2xSTM(581000)ts1100UnivAgg3x25GRep(5800004)ts1100UnivAgg3xGbERep(5800003)ts1100UnivAgg3xGbERep2(5810003)ts1100UnivAgg4xGbE(580000)ts1100UnivAgg4xGbE2(5810002)ts1100UnivAggDFC(540002)ts1100UnivAggDGbE(540001)ts1100UnivAggDGbE2(540003)undefined(0)voa2ch(125)voa8ch(81)voa8chii(110)voa8chsfp(176)The functional type of the board. At least one type is defined for each combination of the following properties of the board: 1 - number of interfaces 2 - type of interfaces 3 - the functionality of the board (can usually be inferred from the types of interfaces) The application should be able to determine which and how many interfaces should be instantiated from the type. Functional types defined so far: Note: The following type is not in use. cu - Control unit tpMr2500 - Multi-rate 2500 Mb/s transponder ocu2 - Dual optical coupler unit (2x1:2) oxc8 - Optical cross-connect 8x8 ports oxc16 - Optical cross-connect 16x16 ports mxp028 - Muxponder 2xSTM-4 + 8xSTM-1 ad1AB, ad1BA - Single add-drop units, A/B- and B/A-type ad2AB, ad2BA - Double add-drop units, A/B- and B/A-type ad4AB, ad4BA - Quad add-drop units, A/B- and B/A-type tpDGbE - Dual GbE transponder oa - Optical amplifier unit oa2 - Dual Optical amplifier unit mdu8Ext - Optical mux/demux unit, extension, 8 ports mdu8Term - Optical mux/demux unit, terminal, 8 ports ocu4 - Quad optical coupler unit (4x1:2) Note: The following type is not in use. mxp004 - Muxponder 4xSTM-1 ad2oaAB - 2 channel add-drop unit, type A/B for use with optical amplifier ad2oaBA - 2 channel add-drop unit, type B/A for use with optical amplifier adcwdm - Single add-drop units for OSC channels. Note: The following type is not in use. ad1spr - 1 channel spur unit tp10G - 10 Gb/s transponder tpLMr2500 - 'Lite' version of the Multi-rate 2500 Mb/s transponder cu1osc - CU with one OSC i/f cu2osc - CU with two OSC i/fs obu - Optical band unit sync2Mhz - 2 MHz synchronization unit mxp8 - 8 tributaries (STM-1 or STM-4) muxponder mxp16 - 16 tributaries (STM-1 or STM-4) muxponder tpDGbED - Dual GbE transponder for DWDM tpDGbEC - Dual GbE transponder for CWDM tpDFcD - Dual fiber channel transponder for DWDM tpDFcC - Dual fiber channel transponder for CWDM tpFcGbED - Fiber channel and GbE transponder for DWDM tpFcGbEC - Fiber channel and GbE transponder for CWDM tpTFcD - Triple fiber channel transponder for DWDM tpQMr - Quad multirate transponder mdu4TermAB - Optical mux/demux unit, terminal, type A/B, 4 ports mdu4TermBA - Optical mux/demux unit, terminal, type B/A, 4 ports adc1wdm - Single add-drop units for CWDM channels. adc2wdm - Double add-drop units for CWDM channels. tp10GLAN - 10 Gb/s LAN DWDM transponder tp10GRC - 10 Gb/s Rate Concerving DWDM transponder escon8 - 8 channel ESCON muxponder tpMr25v2 - Multi-rate 2500 Mb/s transponder version 2 tpD10GbE - Double 10GbE Transponder, Basic Unit tpD10GbER - Double 10GbE Transponder, repeater mdu4ExtAB - Optical mux/demux unit, extension, type A/B, 4 ports mdu4ExtBA - Optical mux/demux unit, extension, type B/A, 4 ports oiuc50100 - Optical interleaver unit 50/100 GHz mROADM1P800 - Reconfigurable optical add/drop multiplexer mxp4x2G5 - 4xSTM-16/10Gb MuxPonder tp10GOtnTc - 10Gb/s C-band Tunable OTN Transponder mdu40Even - 40 channel Mux/Demux unit, even 50GHz DWDM mdu40Odd - 40 channel Mux/Demux unit, odd 50GHz DWDM mdu8Ee - 8 channel 50GHz Mux/Demux, extension port, even, 100GHz spacing mdu8Eo - 8 channel 50GHz Mux/Demux, extension port, odd, 100GHz spacing ocm2p - 2-port Optical Channel Monitor msMxp - MultiService MuxPonder voa8chii - 8ch Variable Optical Attenuator - II msMxpR - MultiService MuxPonder, repeater msMxpDQgbe - Double Quad MuxPonder gbe10Emxp10G - 10xGbE/10GbE Ethernet MuxPonder gbeMxp10GFEC - 10xGbE/10Gb MuxPonder, FEC roadm1x4G100 - 4-port Reconfigurable optical add/drop multiplexer dQgbeMxpR - Double Quad GbE MuxPonder, repeater tpQMS - Quad MultiService transponder tpQMSR - Quad MultiService transponder, repeater gbe22Emxp10G - 22xGbE/10GbE Ethernet MuxPonder mxp4x2G5Oc - 4x2,5G/10Gb MuxPonder in SONET mode voa2ch - 2ch Variable Optical Attenuator msMxp10GTCEr - Multiservice Muxponder Tunable 10G ER msMxp10G - Multiservice Muxponder 10G msMxpQMS2G5 - 2.5Gb Quad MultiService transponder gbe22Emxp10Gii - 22xGbE/10GbE Ethernet MuxPonder Next Generation bsu1x5Even - 1x5 Band Splitter Unit, Even 50 GhZ Spacing bsu1x5Odd - 1x5 Band Splitter Unit, Odd 50 GhZ Spacing mba1 - MS Access Collector 8xE1/T1+2xEth SDH/SONET mode mba1Sonet - Deprecated mba2 - MS Access Collector 16xE1/T1+4xEth SDH/SONET mode mba2Sonet - Deprecated mxpmbh1Sdh - MS Access Hub 4xSTM-1+16xEth SDH mode mxpmbh1Sonet - MS Access Hub 4xOC-3+16xEth SONET mode roadm1x8G50 - 8-port Reconfigurable optical add/drop multiplexer emxp80Gii - 8x10GbE Ethernet MuxPonder-II msMxpQMS2G5 - 2.5Gb Quad MultiService Repeater mxp8iiSdh - 8p SDH 2,5G Muxponder v2 mxp8iiSonet - 8p Sonet 2,5G Muxponder v2 mba2E - MS Access Collector 16xE1/T1+4xEth SDH/SONET mode Temp hardend mba2ptpSdh - MS Access Collector 16xE1/T1+4xEth point to point SDH mode mba2ptpSonet - MS Access Collector 16xE1/T1+4xEth point to point SONET mode mba2EptpSdh - MS Access Collector 16xE1/T1+4xEth point to point SDH mode Temp hardend mba2EptpSonet - MS Access Collector 16xE1/T1+4xEth point to point SONET mode Temp hardend tpq10Gfec - Quad MultiService 10G FEC Transponder mstp40g - Multiservice Transponder 40G msmxp40G - Multiservice Muxponder 40G cuSfpii - CU-SFP/II: CU with 4 SFP OSC ports coD40ev - Dual fiber DWDM Mux/Demux filter, 40 even channels, 50GHz spacing. coD40eve - Dual fiber DWDM Mux/Demux filter with 1310 port, 40 even channels, 50 GHz spacing coD40od - Dual fiber DWDM Mux/Demux filter, 40 odd channels, 50GHz spacing. coD40ode - Dual fiber DWDM Mux/Demux filter with 1310 port, 40 odd channels, 50 GHz spacing dcDk652km20 - Dispersion Compensation Module 20 km dcDk652km40 - Dispersion Compensation Module 40 km dcDk652km60 - Dispersion Compensation Module 60 km dcDk652km80 - Dispersion Compensation Module 80 km dcDk652km100 - Dispersion Compensation Module 100 km dcDk652km120 - Dispersion Compensation Module 120 km dcP652km20 - Dispersion Compensation Module 20 km dcP652km40 - Dispersion Compensation Module 40 km dcP652km60 - Dispersion Compensation Module 60 km dcP652km80 - Dispersion Compensation Module 80 km dcP652km100 - Dispersion Compensation Module 100 km dcP652km120 - Dispersion Compensation Module 120 km emxp40Gii - 4x10GbE Ethernet MuxPonder-II tpqmp - Quad MultiProtocol Transponder tpq10GfecReg - Quad MultiService 10G FEC Regenerator mdu16cl50g - Colorless Mux/Demux Unit voa8chsfp - 8ch SFP-based VOA unit mxp10gotn - OTN Muxponder 10G ocudq - Optical Coupler Unit, Dual Quad (2x1:4) ocuseed2p - 2-Port Seed Light coupler Unit tm4700 - TM2000 Shelf Controller tm4011 - TM2000 40Gb/s Muxponder tm100mxp - TM2000 100Gb/s Muxponder tm100tp - TM2000 100Gb/s Transponder tm100reg - TM2000 100Gb/s Regenerator oypatchcord - Optical Y-patch cord tpq10gfeci - Quad 10G FEC Transponder 1-slot tpq10gfecregi - Quad MultiService 10G FEC Regenerator 1-slot tphex10gotn - Hex 10G OTN Transponder tp100gotn - 100G OTN Transponder emxp220iie - 1x100GbE Ethernet MuxPonder-IIe tpmrHL16G - Hex MultiRate 16G Lite Transponder fhmxp10g - Fronthaul Muxponder 10G mxp100gotn - 100G OTN Muxponder fpu1 - Fiber Protection Unit oaraed21hghyb - RAMAN/EDFA 21dBm HG hybrid board oaraed21hgind - RAMAN/EDFA 21dBm HG individual board emxp3 - 8xMPO Ethernet MuxPonder-III ptio10g - PT Fabric i/O Unit 10&t fhau1 - Fronthaul Access Unit FHAU/1 fha1u1 - Hardened Fronthaul Access Unit tpmrHL16GUni - Hex MultiRate 16G Lite Transponder - - Unidirectional oa1x20dBmVg2 - Variable Gain EDFA 20dBm v2 oa2x20dBmVg2 - Dual Variable Gain EDFA 20dBm v2 fxp400gotn - 400G OTN Flexponder compo24 - CO-MPO24 CO-MPO24 tp100gotnii - 100G OTN Transponder-II rfu1 - Remote Fronthaul Unit roadm1x4f - 4-port Flex Reconfigurable optical add/drop multiplexer ptio100g - PT Fabric I/O Unit 100&t oadm2ch - 2ch DWDM OADM emxp1u - Hardened EMXP Unit emxp1us - Hardened EMXP with SDN mxp200gotn - 200G OTN Muxponder emxp440 - 440GbE Ethernet MuxPonder-III emxp440q - 440GbE Q Ethernet MuxPonder-III oaraed20lghyb - RAMAN/EDFA 20dBm LG hybrid board roadm1x9f - 9-port Flex Reconfigurable optical add/drop multiplexer ocm8p - 8-port Optical Channel Monitor ad1c2fotdr - 1ch CWDM add/drop filter with 1610nm OTDR hdea1600 - High Density Ethernet Aggregator codsf24mpo10104 - Filter for HDEA1600 otdr8p - Optical Time Domain Reflectometer oa1x21dBmVgEC - Variable Gain Extended C-band EDFA 21dBm oa2x21dBmVgEC - Dual Variable Gain Extended C-band EDFA 21dBm emxp800xh - Ethernet Muxponder 800 XHAULEquipmentSubrackTypeINTEGERaux(6)mba1(8)mba2(9)mba2E(10)tm101(4)tm101p(5)tm102(7)tm102pas(11)tm102pas3(12)tm2000(14)tm206Subrack6Slots(9006)tm300(1)tm3000(2)tm3000ii(13)tm3000iie(20)tm301(3)tm301ii(15)tmEmxp1UDc(18)tmEmxpXh800Dc(21)tmFha1UDc1(16)tmHdea1600Dc(19)tmRfuAc1(17)ts1100Subrack12Slots(9013)ts1100Subrack2Slots(9002)ts1100Subrack8Slots(9011)undefined(0)The type of subrack: tm300 - The small subrack (old). tm3000 - The big subrack. tm3000ii - The big subrack, enhanced version. tm3000iie - The big subrack, enhanced second version. tm301 - The small subrack (new). tm301ii - A subrack for maximum four traffic boards, enhanced version. tm101 - Pizza box subrack. tm101p - Passive pizza box subrack. tm102 - An even smaller pizza box. mba1 - Monolith for mobile access mba2 - Monolith for mobile access mba2E - Monolith for mobile access temp hardened tm102pas - Passive pizza box subrack with one full- sized slot and one half-sized slot. tm102pas3 - Passive pizza box subrack with three half-sized slots. tm101p - Passive pizza box subrack. tm2000 - Small subrack for 100 Gbps boards. aux - virtual subrack for external equipment. tmFha1UDc1 - Monolith for mobile front haul. tmRfuAc1 - Remote mobile front haul unit. tmEmxp1UDc - Emxp temp hardened unit. tmHdea1600Dc - Hdea1600 subrack. tmEmxpXh800G/DC - Emxp 800 XHAUL subrack.FirstPbSlotINTEGERslot13(13)slot3(3)slot4(4)undefined(0)A value indicating the first slot where it is possible to configure a passive board in a subrack. undefined - indicates that no value has yet been set. slot3 - Slot 3 is the first passive slot. slot4 - Slot 4 is the first passive slot. slot13 - Slot 13 is the first passive slot.
Traps / Notifications
- equipmentBoardRowStatusActive
1.3.6.1.4.1.8708.2.11.2.6.0.1 - equipmentBoardRowStatusDeleted
1.3.6.1.4.1.8708.2.11.2.6.0.5 - equipmentBoardRowStatusDestroy
1.3.6.1.4.1.8708.2.11.2.6.0.2 - equipmentBoardRowStatusInserted
1.3.6.1.4.1.8708.2.11.2.6.0.3 - equipmentBoardRowStatusRemoved
1.3.6.1.4.1.8708.2.11.2.6.0.4
Groups and compliance
- equipmentBoardGroup
- equipmentBoardGroupV10
- equipmentBoardGroupV11
- equipmentBoardGroupV12
- equipmentBoardGroupV13
- equipmentBoardGroupV14
- equipmentBoardGroupV2
- equipmentBoardGroupV3
- equipmentBoardGroupV4
- equipmentBoardGroupV5
- equipmentBoardGroupV6
- equipmentBoardGroupV7
- equipmentBoardGroupV8
- equipmentBoardGroupV9
- equipmentBoardMinimalGroupV1
- equipmentBoardMinimalGroupV2
- equipmentFanGroup
- equipmentFanGroupV2
- equipmentFanGroupV3
- equipmentFanGroupV4
- equipmentFanGroupV5
- equipmentGeneralGroup
- equipmentGeneralGroupV2
- equipmentGeneralGroupV3
- equipmentGeneralGroupV4
- equipmentGeneralGroupV5
- equipmentGeneralGroupV6
- equipmentGeneralMinimalGroupV1
- equipmentNodeGroup
- equipmentNodeGroupV10
- equipmentNodeGroupV11
- equipmentNodeGroupV2
- equipmentNodeGroupV3
- equipmentNodeGroupV4
- equipmentNodeGroupV8
- equipmentNodeGroupV9
- equipmentNotificationGroup
- equipmentNotificationGroupV2
- equipmentNotificationGroupV3
- equipmentOpticalModuleGroup
- equipmentPowerGroup
- equipmentPowerGroupV2
- equipmentPowerGroupV3
- equipmentPowerGroupV4
- equipmentPowerGroupV5
- equipmentResourceGroup
- equipmentSlotGroup
- equipmentSlotGroupV2
- equipmentSubrackGroup
- equipmentSubrackGroupV10
- equipmentSubrackGroupV2
- equipmentSubrackGroupV3
- equipmentSubrackGroupV4
- equipmentSubrackGroupV5
- equipmentSubrackGroupV6
- equipmentSubrackGroupV7
- equipmentSubrackGroupV8
- equipmentSubrackGroupV9
- lumEquipmentBasicComplV1
- lumEquipmentBasicComplV10
- lumEquipmentBasicComplV11
- lumEquipmentBasicComplV12
- lumEquipmentBasicComplV13
- lumEquipmentBasicComplV14
- lumEquipmentBasicComplV15
- lumEquipmentBasicComplV16
- lumEquipmentBasicComplV17
- lumEquipmentBasicComplV18
- lumEquipmentBasicComplV19
- lumEquipmentBasicComplV2
- lumEquipmentBasicComplV20
- lumEquipmentBasicComplV21
- lumEquipmentBasicComplV22
- lumEquipmentBasicComplV23
- lumEquipmentBasicComplV24
- lumEquipmentBasicComplV25
- lumEquipmentBasicComplV26
- lumEquipmentBasicComplV27
- lumEquipmentBasicComplV28
- lumEquipmentBasicComplV29
- lumEquipmentBasicComplV3
- lumEquipmentBasicComplV30
- lumEquipmentBasicComplV31
- lumEquipmentBasicComplV32
- lumEquipmentBasicComplV33
- lumEquipmentBasicComplV34
- lumEquipmentBasicComplV35
- lumEquipmentBasicComplV36
- lumEquipmentBasicComplV37
- lumEquipmentBasicComplV4
- lumEquipmentBasicComplV5
- lumEquipmentBasicComplV6
- lumEquipmentBasicComplV7
- lumEquipmentBasicComplV8
- lumEquipmentBasicComplV9
- lumEquipmentMinimalComplV1
- lumEquipmentMinimalComplV2
- lumEquipmentMinimalComplV3
- lumEquipmentMinimalComplV4
- lumEquipmentMinimalComplV5
- lumEquipmentMinimalComplV6