IFOTEC-SMI
IFOTECThe Structure of Management Information for the IFOTEC enterprise.
snmptranslate -m IFOTEC-SMI -Tpsnmpwalk -v2c -c <community> -m IFOTEC-SMI <host> 1.3.6.1.4.1.21362Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Iifotec | 1.3.6.1.4.1.21362 | ||||||||||||
identity The Structure of Management Information for the IFOTEC enterprise. | |||||||||||||
| NifotecGeneral | 1.3.6.1.4.1.21362.101 | ||||||||||||
node · current General informations about the IFOTEC product. | |||||||||||||
| NifotecSystem | 1.3.6.1.4.1.21362.101.1 | ||||||||||||
node · current IFOTEC System informations. | |||||||||||||
| SifoSysProductIndex | 1.3.6.1.4.1.21362.101.1.1 | Integer32 | RO | 1 | |||||||||
scalar · Integer32 · read-only · current The ifoSysIndex of the product. Example values from LibreNMS test devices
| |||||||||||||
| TifoSysTable | 1.3.6.1.4.1.21362.101.1.2 | NA | |||||||||||
table · not-accessible · current list of systems present. | |||||||||||||
| RifoSysEntry | 1.3.6.1.4.1.21362.101.1.2.1 | NA | |||||||||||
| CifoSysIndex | 1.3.6.1.4.1.21362.101.1.2.1.1 | Integer32 | NA | ||||||||||
column · Integer32 · not-accessible · current A unique value, greater than zero, for each product. | |||||||||||||
| CifoSysRef | 1.3.6.1.4.1.21362.101.1.2.1.2 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current Product reference | |||||||||||||
| CifoSysInfo | 1.3.6.1.4.1.21362.101.1.2.1.3 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current Product information | |||||||||||||
| CifoSysFamilly | 1.3.6.1.4.1.21362.101.1.2.1.4 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current Product familly | |||||||||||||
| CifoSysSerialNumber | 1.3.6.1.4.1.21362.101.1.2.1.5 | DisplayString | RO | 0051 | |||||||||
column · DisplayString · read-only · current Serial number Example values from LibreNMS test devices
| |||||||||||||
| CifoSysDateCode | 1.3.6.1.4.1.21362.101.1.2.1.6 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current Date code | |||||||||||||
| CifoSysFirmware | 1.3.6.1.4.1.21362.101.1.2.1.7 | DisplayString | RO | 1.0.5d | |||||||||
column · DisplayString · read-only · current Firmware version Example values from LibreNMS test devices
| |||||||||||||
| CifoSysBootloader | 1.3.6.1.4.1.21362.101.1.2.1.8 | DisplayString | RO | x.x.x | |||||||||
column · DisplayString · read-only · current Bootloader version Example values from LibreNMS test devices
| |||||||||||||
| CifoSysDescr | 1.3.6.1.4.1.21362.101.1.2.1.9 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current Administratively-assigned name (sysName) | |||||||||||||
| CifoSysLocation | 1.3.6.1.4.1.21362.101.1.2.1.10 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current Physical location (sysLocation) | |||||||||||||
| CifoSysContact | 1.3.6.1.4.1.21362.101.1.2.1.11 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current Physical location (sysContact) | |||||||||||||
| CifoSysUpTime | 1.3.6.1.4.1.21362.101.1.2.1.12 | TimeTicks | RO | ||||||||||
column · TimeTicks · read-only · current The time (in hundredths of a second) since the network management portion of the system was last re-initialized (sysUpTime). | |||||||||||||
| TifoSysMibTable | 1.3.6.1.4.1.21362.101.1.3 | NA | |||||||||||
table · not-accessible · current list of mibs presents in the system. | |||||||||||||
| RifoSysMibEntry | 1.3.6.1.4.1.21362.101.1.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing mib informations. | |||||||||||||
| CifoSysORIfoSysIndex | 1.3.6.1.4.1.21362.101.1.3.1.1 | Integer32 | NA | ||||||||||
column · Integer32 · not-accessible · current The index value which uniquely identifies the system in ifoSysMibTable. | |||||||||||||
| CifoSysORIndex | 1.3.6.1.4.1.21362.101.1.3.1.2 | Integer32 | NA | ||||||||||
column · Integer32 · not-accessible · current A unique value, greater than zero, for each mib presents in the system. | |||||||||||||
| CifoSysORID | 1.3.6.1.4.1.21362.101.1.3.1.3 | OBJECT IDENTIFIER | RO | ||||||||||
column · OBJECT IDENTIFIER · read-only · current An unique identifier to designate the mib. | |||||||||||||
| CifoSysORDescr | 1.3.6.1.4.1.21362.101.1.3.1.4 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current Description of the mib. | |||||||||||||
| NifotecTemperatures | 1.3.6.1.4.1.21362.101.2 | ||||||||||||
node · current IFOTEC Temperature Sensors. | |||||||||||||
| TifoTemperatureTable | 1.3.6.1.4.1.21362.101.2.1 | NA | |||||||||||
table · not-accessible · current A list of sensors. | |||||||||||||
| RifoTemperatureEntry | 1.3.6.1.4.1.21362.101.2.1.1 | NA | |||||||||||
row · not-accessible · current An entry containing sensor informations. | |||||||||||||
| CifoTempIfoSysIndex | 1.3.6.1.4.1.21362.101.2.1.1.1 | Integer32 | NA | ||||||||||
column · Integer32 · not-accessible · current The index value which uniquely identifies the system in ifoSysMibTable. | |||||||||||||
| CifoTempIndex | 1.3.6.1.4.1.21362.101.2.1.1.2 | Integer32 | NA | ||||||||||
column · Integer32 · not-accessible · current A unique value, greater than zero, for each temperature sensor. | |||||||||||||
| CifoTempName | 1.3.6.1.4.1.21362.101.2.1.1.3 | DisplayString | RO | INTERNAL_TEMPERATURE1 | |||||||||
column · DisplayString · read-only · current The name of the temperature sensor. Example values from LibreNMS test devices
| |||||||||||||
| CifoTempDescr | 1.3.6.1.4.1.21362.101.2.1.1.4 | DisplayString | RO | Internal Temperature 1 | |||||||||
column · DisplayString · read-only · current The description of the temeprature sensor. Example values from LibreNMS test devices
| |||||||||||||
| CifoTempValue | 1.3.6.1.4.1.21362.101.2.1.1.5 | IfotecTenthCelsius | RO | 300 | |||||||||
column · IfotecTenthCelsius · read-only · current the value of the sensor in 0.1 degree Celsius.
Example values from LibreNMS test devices
| |||||||||||||
| CifoTempAlarmStatus | 1.3.6.1.4.1.21362.101.2.1.1.6 | IfotecDataStatus | RO | 2 | |||||||||
column · IfotecDataStatus · read-only · current Indicates the sensor alarm status. Example values from LibreNMS test devices
| |||||||||||||
| CifoTempLowThldAlarm | 1.3.6.1.4.1.21362.101.2.1.1.7 | IfotecTenthCelsius | RO | -100 | |||||||||
column · IfotecTenthCelsius · read-only · current the value in 0.1 degree Celsius of the low threshold alarm.
Example values from LibreNMS test devices
| |||||||||||||
| CifoTempHighThldAlarm | 1.3.6.1.4.1.21362.101.2.1.1.8 | IfotecTenthCelsius | RO | 900 | |||||||||
column · IfotecTenthCelsius · read-only · current the value in 0.1 degree Celsius of the high threshold alarm.
Example values from LibreNMS test devices
| |||||||||||||
| CifoTempLowThldWarning | 1.3.6.1.4.1.21362.101.2.1.1.9 | IfotecTenthCelsius | RO | 0 | |||||||||
column · IfotecTenthCelsius · read-only · current the value in 0.1 degree Celsius of the low threshold warning.
Example values from LibreNMS test devices
| |||||||||||||
| CifoTempHighThldWarning | 1.3.6.1.4.1.21362.101.2.1.1.10 | IfotecTenthCelsius | RO | 850 | |||||||||
column · IfotecTenthCelsius · read-only · current the value in 0.1 degree Celsius of the high threshold warning.
Example values from LibreNMS test devices
| |||||||||||||
| NifotecIO | 1.3.6.1.4.1.21362.101.3 | ||||||||||||
node · current IFOTEC Input Output. | |||||||||||||
| NifotecIODigitalInput | 1.3.6.1.4.1.21362.101.3.1 | ||||||||||||
node · current IFOTEC Digital Input. | |||||||||||||
| TifotecIODigitalInputTable | 1.3.6.1.4.1.21362.101.3.1.1 | NA | |||||||||||
table · not-accessible · current A list of Digital Input. | |||||||||||||
| RifoIODigitalInputEntry | 1.3.6.1.4.1.21362.101.3.1.1.1 | NA | |||||||||||
row · not-accessible · current An entry containing the Digital Input informations. | |||||||||||||
| CifoDigitalInputIfoSysIndex | 1.3.6.1.4.1.21362.101.3.1.1.1.1 | Integer32 | NA | ||||||||||
column · Integer32 · not-accessible · current The index value which uniquely identifies the system in ifoSysMibTable. | |||||||||||||
| CifoDigitalInputIndex | 1.3.6.1.4.1.21362.101.3.1.1.1.2 | Integer32 | NA | ||||||||||
column · Integer32 · not-accessible · current A unique value, greater than zero, for each Digital Input. | |||||||||||||
| CifoDigitalInputName | 1.3.6.1.4.1.21362.101.3.1.1.1.3 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current The name of the Digital Input. | |||||||||||||
| CifoDigitalInputDescr | 1.3.6.1.4.1.21362.101.3.1.1.1.4 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current The description of the Digital Input. | |||||||||||||
| CifoDigitalInputType | 1.3.6.1.4.1.21362.101.3.1.1.1.5 | IfotecDigitalInputType | RO | ||||||||||
column · IfotecDigitalInputType · read-only · current The type of the Digital Input. | |||||||||||||
| CifoDigitalInputValue | 1.3.6.1.4.1.21362.101.3.1.1.1.6 | IfotecDigitalValue | RO | ||||||||||
column · IfotecDigitalValue · read-only · current The value of the Digital Input. | |||||||||||||
| CifoDigitalInputAlarmStatus | 1.3.6.1.4.1.21362.101.3.1.1.1.7 | IfotecDataStatus | RO | ||||||||||
column · IfotecDataStatus · read-only · current Indicates the Digital Input alarm status. | |||||||||||||
| NifotecIODigitalOutput | 1.3.6.1.4.1.21362.101.3.2 | ||||||||||||
node · current IFOTEC Digital Output. | |||||||||||||
| TifoIODigitalOutputTable | 1.3.6.1.4.1.21362.101.3.2.1 | NA | |||||||||||
table · not-accessible · current A list of Digital Output. | |||||||||||||
| RifoIODigitalOutputEntry | 1.3.6.1.4.1.21362.101.3.2.1.1 | NA | |||||||||||
row · not-accessible · current An entry containing the Digital Output informations. | |||||||||||||
| CifoDigitalOutputIfoSysIndex | 1.3.6.1.4.1.21362.101.3.2.1.1.1 | Integer32 | NA | ||||||||||
column · Integer32 · not-accessible · current The index value which uniquely identifies the system in ifoSysMibTable. | |||||||||||||
| CifoDigitalOutputIndex | 1.3.6.1.4.1.21362.101.3.2.1.1.2 | Integer32 | NA | ||||||||||
column · Integer32 · not-accessible · current A unique value, greater than zero, for each Digital Output. | |||||||||||||
| CifoDigitalOutputName | 1.3.6.1.4.1.21362.101.3.2.1.1.3 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current The name of the Digital Output. | |||||||||||||
| CifoDigitalOutputDescr | 1.3.6.1.4.1.21362.101.3.2.1.1.4 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current The description of the Digital Output. | |||||||||||||
| CifoDigitalOutputType | 1.3.6.1.4.1.21362.101.3.2.1.1.5 | IfotecDigitalOutputType | RO | ||||||||||
column · IfotecDigitalOutputType · read-only · current The type of the Digital Output. | |||||||||||||
| CifoDigitalOutputValue | 1.3.6.1.4.1.21362.101.3.2.1.1.6 | IfotecDigitalValue | RW | ||||||||||
column · IfotecDigitalValue · read-write · current The value of the Digital Output. | |||||||||||||
| CifoDigitalOutputAlarmStatus | 1.3.6.1.4.1.21362.101.3.2.1.1.7 | IfotecDataStatus | RO | ||||||||||
column · IfotecDataStatus · read-only · current Indicates the Digital Output alarm status. | |||||||||||||
| NifotecLog | 1.3.6.1.4.1.21362.101.4 | ||||||||||||
node · current IFOTEC Logs. | |||||||||||||
| SifoLogNotifLastIdSend | 1.3.6.1.4.1.21362.101.4.1 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current ID of the last notif send. | |||||||||||||
| NifotecLogNotif | 1.3.6.1.4.1.21362.101.4.2 | ||||||||||||
node · current IFOTEC Log Notifications. | |||||||||||||
| SifoLogNotifSysIndex | 1.3.6.1.4.1.21362.101.4.2.1 | Integer32 | AN | ||||||||||
scalar · Integer32 · accessible-for-notify · current The index value which uniquely identifies the system in ifoSysMibTable. | |||||||||||||
| SifoLogNotifId | 1.3.6.1.4.1.21362.101.4.2.2 | Integer32 | AN | ||||||||||
scalar · Integer32 · accessible-for-notify · current ID of the Notification. | |||||||||||||
| SifoLogNotifTimestamp | 1.3.6.1.4.1.21362.101.4.2.3 | Integer32 | AN | ||||||||||
scalar · Integer32 · accessible-for-notify · current Timestamp of the event. | |||||||||||||
| SifoLogNotifType | 1.3.6.1.4.1.21362.101.4.2.4 | INTEGER | AN | ||||||||||
scalar · INTEGER · accessible-for-notify · current Type of the event. One value per event, never a combination: the powers of two come from the logging filter, which uses them as a mask elsewhere. Do not convert to BITS: the agent sends a single ENUM_LOG_TYPE. Values are the same on all products. poeEvent(64) is emitted only by PoE products, ioChange(128) only by products with digital inputs.
| |||||||||||||
| SifoLogNotifSequence | 1.3.6.1.4.1.21362.101.4.2.5 | Integer32 | AN | ||||||||||
scalar · Integer32 · accessible-for-notify · current Sequence number of the event. | |||||||||||||
| SifoLogNotifDesc | 1.3.6.1.4.1.21362.101.4.2.6 | DisplayString | AN | ||||||||||
scalar · DisplayString · accessible-for-notify · current Description of the event. | |||||||||||||
| SifoLogNotifStatus | 1.3.6.1.4.1.21362.101.4.2.7 | IfotecDataStatus | AN | ||||||||||
scalar · IfotecDataStatus · accessible-for-notify · current Status of the event. | |||||||||||||
| SifoLogNotifSeverity | 1.3.6.1.4.1.21362.101.4.2.8 | INTEGER | AN | ||||||||||
scalar · INTEGER · accessible-for-notify · current Severity of the event.
| |||||||||||||
| NifotecSFP | 1.3.6.1.4.1.21362.101.5 | ||||||||||||
node · current IFOTEC SFP. | |||||||||||||
| TifoSFPTable | 1.3.6.1.4.1.21362.101.5.1 | NA | |||||||||||
table · not-accessible · current A list of SFP. | |||||||||||||
| RifoSFPEntry | 1.3.6.1.4.1.21362.101.5.1.1 | NA | |||||||||||
row · not-accessible · current An entry containing sensor informations.
| |||||||||||||
| CifoSFPIfoSysIndex | 1.3.6.1.4.1.21362.101.5.1.1.1 | Integer32 | NA | ||||||||||
column · Integer32 · not-accessible · current The index value which uniquely identifies the system in ifoSysMibTable. | |||||||||||||
| CifoSFPIndex | 1.3.6.1.4.1.21362.101.5.1.1.2 | Integer32 | NA | ||||||||||
column · Integer32 · not-accessible · current A unique value, greater than zero, for each SFP. | |||||||||||||
| CifoSFPportName | 1.3.6.1.4.1.21362.101.5.1.1.3 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current The name of the port. | |||||||||||||
| CifoSFPisPlugged | 1.3.6.1.4.1.21362.101.5.1.1.4 | IfotecYesNoType | RO | ||||||||||
column · IfotecYesNoType · read-only · current Indicates the presence of the SFP. | |||||||||||||
| CifoSFPConnectorType | 1.3.6.1.4.1.21362.101.5.1.1.5 | IfotecSFPConnectorType | RO | ||||||||||
column · IfotecSFPConnectorType · read-only · current Indicates the type of the SFP connector. | |||||||||||||
| CifoSFPmode | 1.3.6.1.4.1.21362.101.5.1.1.6 | IfotecSFPmodeType | RO | ||||||||||
column · IfotecSFPmodeType · read-only · current Indicates the operating mode of the SFP. | |||||||||||||
| CifoSFPrxSignalDetect | 1.3.6.1.4.1.21362.101.5.1.1.7 | IfotecYesNoType | RO | ||||||||||
column · IfotecYesNoType · read-only · current Indicates the presence of Rx optical signal. | |||||||||||||
| CifoSFPAlarmeOptEnb | 1.3.6.1.4.1.21362.101.5.1.1.8 | IfotecYesNoType | RO | ||||||||||
column · IfotecYesNoType · read-only · current Indicates if the optical alarm is enabled. | |||||||||||||
| CifoSFPAlarmeOptStatus | 1.3.6.1.4.1.21362.101.5.1.1.9 | IfotecDataStatus | RO | ||||||||||
column · IfotecDataStatus · read-only · current Indicates the status of the optical alarm. | |||||||||||||
| CifoSFPrxPowerVal | 1.3.6.1.4.1.21362.101.5.1.1.10 | IfotecTenthDbm | RO | ||||||||||
column · IfotecTenthDbm · read-only · current The value of RX optical value in 0.1 dBm.
| |||||||||||||
| CifoSFPrxPowerErrThsdHigh | 1.3.6.1.4.1.21362.101.5.1.1.11 | IfotecTenthDbm | RO | ||||||||||
column · IfotecTenthDbm · read-only · current The value in 0.1dBm of the RX optical high threshold alarm.
| |||||||||||||
| CifoSFPrxPowerErrThsdLow | 1.3.6.1.4.1.21362.101.5.1.1.12 | IfotecTenthDbm | RO | ||||||||||
column · IfotecTenthDbm · read-only · current The value in 0.1dBm of the RX optical low threshold alarm.
| |||||||||||||
| CifoSFPrxPowerWrngThsdHigh | 1.3.6.1.4.1.21362.101.5.1.1.13 | IfotecTenthDbm | RO | ||||||||||
column · IfotecTenthDbm · read-only · current The value in 0.1dBm of the RX optical high threshold warning.
| |||||||||||||
| CifoSFPrxPowerWrngThsdLow | 1.3.6.1.4.1.21362.101.5.1.1.14 | IfotecTenthDbm | RO | ||||||||||
column · IfotecTenthDbm · read-only · current The value in 0.1dBm of the RX optical low threshold warning.
| |||||||||||||
| CifoSFPrxPowerStatus | 1.3.6.1.4.1.21362.101.5.1.1.15 | IfotecDataStatus | RO | ||||||||||
column · IfotecDataStatus · read-only · current Indicates the status of the RX optical alarm. | |||||||||||||
| CifoSFPtxPowerVal | 1.3.6.1.4.1.21362.101.5.1.1.16 | IfotecTenthDbm | RO | ||||||||||
column · IfotecTenthDbm · read-only · current The value of TX optical value in 0.1 dBm.
| |||||||||||||
| CifoSFPtxPowerErrThsdHigh | 1.3.6.1.4.1.21362.101.5.1.1.17 | IfotecTenthDbm | RO | ||||||||||
column · IfotecTenthDbm · read-only · current The value in 0.1dBm of the TX optical high threshold alarm.
| |||||||||||||
| CifoSFPtxPowerErrThsdLow | 1.3.6.1.4.1.21362.101.5.1.1.18 | IfotecTenthDbm | RO | ||||||||||
column · IfotecTenthDbm · read-only · current The value in 0.1dBm of the TX optical low threshold alarm.
| |||||||||||||
| CifoSFPtxPowerWrngThsdHigh | 1.3.6.1.4.1.21362.101.5.1.1.19 | IfotecTenthDbm | RO | ||||||||||
column · IfotecTenthDbm · read-only · current The value in 0.1dBm of the TX optical high threshold warning.
| |||||||||||||
| CifoSFPtxPowerWrngThsdLow | 1.3.6.1.4.1.21362.101.5.1.1.20 | IfotecTenthDbm | RO | ||||||||||
column · IfotecTenthDbm · read-only · current The value in 0.1dBm of the TX optical low threshold warning.
| |||||||||||||
| CifoSFPtxPowerStatus | 1.3.6.1.4.1.21362.101.5.1.1.21 | IfotecDataStatus | RO | ||||||||||
column · IfotecDataStatus · read-only · current Indicates the status of the TX optical warning. | |||||||||||||
| NifotecModules | 1.3.6.1.4.1.21362.102 | ||||||||||||
node · current ifotecModules provides a root object identifier from which MODULE-IDENTITY values may be assigned. | |||||||||||||
Textual conventions
IfotecDataStatusINTEGERerror(6)errorHighDataOverflow(11)errorHighThreshold(8)errorLowDataOverflow(10)errorLowThreshold(7)errorWrongData(9)noData(1)ok(2)warning(3)warningHighThreshold(5)warningLowThreshold(4)Represents the data status.
IfotecDigitalInputTypeINTEGERdryContact(1)wetContact(2)Represents the type of digital input.
IfotecDigitalOutputTypeINTEGERrelayComNc(2)relayComNo(1)relayNoComNc(3)Represents the type of digital output.
IfotecDigitalValueINTEGERactive(1)inactive(2)Represents the value of digital input/output.
IfotecSFPConnectorTypeINTEGERdac(5)lc(3)rj45(4)sc(2)undefined(1)SFP Connector type enum.
IfotecSFPmodeTypeINTEGERcontactor(3)ethernet(2)undefined(1)SFP mode.
IfotecTenthCelsiusInteger32Display hint:
d-1A temperature, in tenths of degree Celsius: the value 235 is 23.5 degrees Celsius.
IfotecTenthDbmInteger32Display hint:
d-1An optical power, in tenths of dBm: the value -52 is -5.2 dBm.
IfotecYesNoTypeINTEGERno(2)yes(1)Yes,No enum.