ICT-PDU-MIB
Innovative Circuit Technology Ltd.snmptranslate -m ICT-PDU-MIB -Tpsnmpwalk -v2c -c <community> -m ICT-PDU-MIB <host> 1.3.6.1.4.1.39145Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| NictPower | 1.3.6.1.4.1.39145 | ||||||||||||||||||||
| NdistPanel | 1.3.6.1.4.1.39145.10 | ||||||||||||||||||||
| !sysUndervoltageAlarmTrap | 1.3.6.1.4.1.39145.10.0.101 | ||||||||||||||||||||
| !sysOvervoltageAlarmTrap | 1.3.6.1.4.1.39145.10.0.102 | ||||||||||||||||||||
| !sysOvercurrentAlarmTrap | 1.3.6.1.4.1.39145.10.0.103 | ||||||||||||||||||||
| !fuseAlarmTrap | 1.3.6.1.4.1.39145.10.0.104 | ||||||||||||||||||||
| !undercurrentAlarmTrap | 1.3.6.1.4.1.39145.10.0.105 | ||||||||||||||||||||
| !overcurrentAlarmTrap | 1.3.6.1.4.1.39145.10.0.106 | ||||||||||||||||||||
| !loadshedTrap | 1.3.6.1.4.1.39145.10.0.107 | ||||||||||||||||||||
| !alarmInputTrap | 1.3.6.1.4.1.39145.10.0.108 | ||||||||||||||||||||
| !sysUndervoltageAlarmClear | 1.3.6.1.4.1.39145.10.0.111 | ||||||||||||||||||||
| !sysOvervoltageAlarmClear | 1.3.6.1.4.1.39145.10.0.112 | ||||||||||||||||||||
| !sysOvercurrentAlarmClear | 1.3.6.1.4.1.39145.10.0.113 | ||||||||||||||||||||
| !fuseAlarmClear | 1.3.6.1.4.1.39145.10.0.114 | ||||||||||||||||||||
| !undercurrentAlarmClear | 1.3.6.1.4.1.39145.10.0.115 | ||||||||||||||||||||
| !overcurrentAlarmClear | 1.3.6.1.4.1.39145.10.0.116 | ||||||||||||||||||||
| !loadshedClear | 1.3.6.1.4.1.39145.10.0.117 | ||||||||||||||||||||
notification Trap generated when an Output has recovered from a Load-Shedding condition
| |||||||||||||||||||||
| !alarmInputClear | 1.3.6.1.4.1.39145.10.0.118 | ||||||||||||||||||||
| !scheduledPowerCycle | 1.3.6.1.4.1.39145.10.0.126 | ||||||||||||||||||||
| SdeviceModel | 1.3.6.1.4.1.39145.10.1 | DisplayString | RO | mandatory | ICT180S-12BRCP | ||||||||||||||||
scalar · DisplayString · read-only · mandatory Model Number Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdeviceName | 1.3.6.1.4.1.39145.10.2 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Site Name | |||||||||||||||||||||
| SdeviceHardware | 1.3.6.1.4.1.39145.10.3 | INTEGER (0..127) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..127) · read-only · mandatory Hardware Version | |||||||||||||||||||||
| SdeviceFirmware | 1.3.6.1.4.1.39145.10.4 | DisplayString | RO | mandatory | 2.08 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory Firmware Version Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdeviceMacAddress | 1.3.6.1.4.1.39145.10.5 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory MAC Address | |||||||||||||||||||||
| SsystemVoltage | 1.3.6.1.4.1.39145.10.6 | DisplayString | RO | mandatory | 46.0 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory System Voltage (Volts) Example values from LibreNMS test devices
| |||||||||||||||||||||
| SsystemCurrent | 1.3.6.1.4.1.39145.10.7 | DisplayString | RO | mandatory | 0.2 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory System Current (Amps) Example values from LibreNMS test devices
| |||||||||||||||||||||
| ToutputTable | 1.3.6.1.4.1.39145.10.8 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Output Table | |||||||||||||||||||||
| RoutputEntry | 1.3.6.1.4.1.39145.10.8.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory
| |||||||||||||||||||||
| CoutputNumber | 1.3.6.1.4.1.39145.10.8.1.1 | Integer32 | RO | mandatory | 0 | ||||||||||||||||
| CoutputName | 1.3.6.1.4.1.39145.10.8.1.2 | DisplayString | RO | mandatory | test | ||||||||||||||||
| CoutputCurrent | 1.3.6.1.4.1.39145.10.8.1.3 | DisplayString | RO | mandatory | 0.0 | ||||||||||||||||
column · DisplayString · read-only · mandatory Output Current (Amps) Example values from LibreNMS test devices
| |||||||||||||||||||||
| CoutputFuseStatus | 1.3.6.1.4.1.39145.10.8.1.4 | INTEGER | RO | mandatory | ok(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory Output Fuse Status ('1' indicates Fuse is OK, and '2' indicates Fuse is OPEN)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CoutputEnable | 1.3.6.1.4.1.39145.10.8.1.5 | INTEGER | RW | mandatory | enabled(1) | ||||||||||||||||
| CoutputCurrentX100 | 1.3.6.1.4.1.39145.10.8.1.6 | Integer32 | RO | mandatory | |||||||||||||||||
column · Integer32 · read-only · mandatory Output Current (Amps X 100) | |||||||||||||||||||||
| TalarmTable | 1.3.6.1.4.1.39145.10.9 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Alarm Input Table | |||||||||||||||||||||
| RalarmEntry | 1.3.6.1.4.1.39145.10.9.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory
| |||||||||||||||||||||
| CalarmNumber | 1.3.6.1.4.1.39145.10.9.1.1 | Integer32 | RO | mandatory | |||||||||||||||||
column · Integer32 · read-only · mandatory Alarm Input Number | |||||||||||||||||||||
| CalarmName | 1.3.6.1.4.1.39145.10.9.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Alarm Input Name | |||||||||||||||||||||
| CalarmStatus | 1.3.6.1.4.1.39145.10.9.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Alarm Input Status ('1' indicates Alarm is INACTIVE,'2' indicates Alarm is READY, and '3' indicates Alarm is in an ALARM condition)
| |||||||||||||||||||||
| TbusTable | 1.3.6.1.4.1.39145.10.10 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Bus Table | |||||||||||||||||||||
| RbusEntry | 1.3.6.1.4.1.39145.10.10.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory
| |||||||||||||||||||||
| CbusNumber | 1.3.6.1.4.1.39145.10.10.1.1 | Integer32 | RO | mandatory | |||||||||||||||||
column · Integer32 · read-only · mandatory Bus Number | |||||||||||||||||||||
| CbusName | 1.3.6.1.4.1.39145.10.10.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Bus Name | |||||||||||||||||||||
| CbusVoltage | 1.3.6.1.4.1.39145.10.10.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Bus Voltage (Volts) | |||||||||||||||||||||
| CbusCurrent | 1.3.6.1.4.1.39145.10.10.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Total Bus Current (Amps) | |||||||||||||||||||||
| CbusVoltageX100 | 1.3.6.1.4.1.39145.10.10.1.5 | Integer32 | RO | mandatory | |||||||||||||||||
column · Integer32 · read-only · mandatory Bus Voltage (Volts X 100) | |||||||||||||||||||||
| CbusCurrentX100 | 1.3.6.1.4.1.39145.10.10.1.6 | Integer32 | RO | mandatory | |||||||||||||||||
column · Integer32 · read-only · mandatory Total Bus Current (Amps X 100) | |||||||||||||||||||||
Traps / Notifications
- alarmInputClear
1.3.6.1.4.1.39145.10.0.118 - alarmInputTrap
1.3.6.1.4.1.39145.10.0.108 - fuseAlarmClear
1.3.6.1.4.1.39145.10.0.114 - fuseAlarmTrap
1.3.6.1.4.1.39145.10.0.104 - loadshedClear
1.3.6.1.4.1.39145.10.0.117 - loadshedTrap
1.3.6.1.4.1.39145.10.0.107 - overcurrentAlarmClear
1.3.6.1.4.1.39145.10.0.116 - overcurrentAlarmTrap
1.3.6.1.4.1.39145.10.0.106 - scheduledPowerCycle
1.3.6.1.4.1.39145.10.0.126 - sysOvercurrentAlarmClear
1.3.6.1.4.1.39145.10.0.113 - sysOvercurrentAlarmTrap
1.3.6.1.4.1.39145.10.0.103 - sysOvervoltageAlarmClear
1.3.6.1.4.1.39145.10.0.112 - sysOvervoltageAlarmTrap
1.3.6.1.4.1.39145.10.0.102 - sysUndervoltageAlarmClear
1.3.6.1.4.1.39145.10.0.111 - sysUndervoltageAlarmTrap
1.3.6.1.4.1.39145.10.0.101 - undercurrentAlarmClear
1.3.6.1.4.1.39145.10.0.115 - undercurrentAlarmTrap
1.3.6.1.4.1.39145.10.0.105