BLADE-MIB
IBM (https://w3.ibm.com/standards )snmptranslate -m BLADE-MIB -Tpsnmpwalk -v2c -c <community> -m BLADE-MIB <host> 1.3.6.1.4.1.2Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, Unsigned32, enterprises, iso, private |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Nibm | 1.3.6.1.4.1.2 | |||
| NibmAgents | 1.3.6.1.4.1.2.3 | |||
| NnetfinitySupportProcessorAgent | 1.3.6.1.4.1.2.3.51 | |||
| NbladeCenterSnmpMIB | 1.3.6.1.4.1.2.3.51.2 | |||
| Nmonitors | 1.3.6.1.4.1.2.3.51.2.2 | |||
| Ntemperature | 1.3.6.1.4.1.2.3.51.2.2.1 | |||
| NplanarTemp | 1.3.6.1.4.1.2.3.51.2.2.1.1 | |||
| SmmTemp | 1.3.6.1.4.1.2.3.51.2.2.1.1.2 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Management module temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system. | ||||
| NambientTemp | 1.3.6.1.4.1.2.3.51.2.2.1.5 | |||
| SfrontPanelTemp | 1.3.6.1.4.1.2.3.51.2.2.1.5.1 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The front panel temperature in degrees centigrade(C).
This is surrounding temperature where the system is installed.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system. | ||||
| SfrontPanel2Temp | 1.3.6.1.4.1.2.3.51.2.2.1.5.2 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The front panel 2 temperature in degrees centigrade(C).
This is surrounding temperature where the system is installed.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
NOTE: This MIB object is for BladeCenter HT only | ||||
| Nvoltage | 1.3.6.1.4.1.2.3.51.2.2.2 | |||
| NplanarVolt | 1.3.6.1.4.1.2.3.51.2.2.2.1 | |||
| Splus5Volt | 1.3.6.1.4.1.2.3.51.2.2.2.1.1 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory +5 Volt power supply voltage reading expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system. | ||||
| Splus3Pt3Volt | 1.3.6.1.4.1.2.3.51.2.2.2.1.2 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory +3.3 Volt power supply voltage reading expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system. | ||||
| Splus12Volt | 1.3.6.1.4.1.2.3.51.2.2.2.1.3 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory +12 Volt power supply voltage reading expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system. | ||||
| Sminus5Volt | 1.3.6.1.4.1.2.3.51.2.2.2.1.5 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory -5 Volt power supply voltage reading expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system. | ||||
| Splus2Pt5Volt | 1.3.6.1.4.1.2.3.51.2.2.2.1.6 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory +2.5 Volt power supply voltage reading expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system. | ||||
| Splus1Pt8Volt | 1.3.6.1.4.1.2.3.51.2.2.2.1.8 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory +1.8 Volt power supply voltage reading expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system. | ||||
| Nblowers | 1.3.6.1.4.1.2.3.51.2.2.3 | |||
| Sblower1speed | 1.3.6.1.4.1.2.3.51.2.2.3.1 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Blower 1 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Sblower2speed | 1.3.6.1.4.1.2.3.51.2.2.3.2 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Blower 2 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Sblower3speed | 1.3.6.1.4.1.2.3.51.2.2.3.3 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Blower 3 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for BladeCenter T, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Sblower4speed | 1.3.6.1.4.1.2.3.51.2.2.3.4 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Blower 4 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for BladeCenter T, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Sblower1State | 1.3.6.1.4.1.2.3.51.2.2.3.10 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The health state for blower 1. NOTE: Blowers are also referred to as Chassis Cooling Devices.
| ||||
| Sblower2State | 1.3.6.1.4.1.2.3.51.2.2.3.11 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The health state for blower 2. NOTE: Blowers are also referred to as Chassis Cooling Devices.
| ||||
| Sblower3State | 1.3.6.1.4.1.2.3.51.2.2.3.12 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The health state for blower 3. NOTE: This MIB object is for BladeCenter T and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
| ||||
| Sblower4State | 1.3.6.1.4.1.2.3.51.2.2.3.13 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The health state for blower 4. NOTE: This MIB object is for BladeCenter T and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
| ||||
| Sblower1speedRPM | 1.3.6.1.4.1.2.3.51.2.2.3.20 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Blower 1 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Sblower2speedRPM | 1.3.6.1.4.1.2.3.51.2.2.3.21 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Blower 2 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Sblower3speedRPM | 1.3.6.1.4.1.2.3.51.2.2.3.22 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Blower 3 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Sblower4speedRPM | 1.3.6.1.4.1.2.3.51.2.2.3.23 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Blower 4 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Sblower1ControllerState | 1.3.6.1.4.1.2.3.51.2.2.3.30 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The health state for the controller for blower 1. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
| ||||
| Sblower2ControllerState | 1.3.6.1.4.1.2.3.51.2.2.3.31 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The health state for the controller for blower 2. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
| ||||
| Sblower3ControllerState | 1.3.6.1.4.1.2.3.51.2.2.3.32 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The health state for the controller for blower 3. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
| ||||
| Sblower4ControllerState | 1.3.6.1.4.1.2.3.51.2.2.3.33 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The health state for the controller for blower 4. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
| ||||
| Sblower1ExhaustTemp | 1.3.6.1.4.1.2.3.51.2.2.3.40 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The exhaust temperature in degrees Celsius for blower 1. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Sblower2ExhaustTemp | 1.3.6.1.4.1.2.3.51.2.2.3.41 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The exhaust temperature in degrees Celsius for blower 2. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Sblower3ExhaustTemp | 1.3.6.1.4.1.2.3.51.2.2.3.42 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The exhaust temperature in degrees Celsius for blower 3. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Sblower4ExhaustTemp | 1.3.6.1.4.1.2.3.51.2.2.3.43 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The exhaust temperature in degrees Celsius for blower 4. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| NpowerModuleHealth | 1.3.6.1.4.1.2.3.51.2.2.4 | |||
| TpowerModuleHealthTable | 1.3.6.1.4.1.2.3.51.2.2.4.1 | NA | mandatory | |
table · not-accessible · mandatory Table of power module health information. Contains the power health information for each power module. | ||||
| RpowerModuleHealthEntry | 1.3.6.1.4.1.2.3.51.2.2.4.1.1 | NA | mandatory | |
| CpowerModuleIndex | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power module sequence index. | ||||
| CpowerModuleExists | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the power module specified exists or not.
| ||||
| CpowerModuleState | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The health state for the power module.
| ||||
| CpowerModuleDetails | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The details for this power module. | ||||
| NspStatus | 1.3.6.1.4.1.2.3.51.2.2.5 | |||
| NmmBistAndChassisStatus | 1.3.6.1.4.1.2.3.51.2.2.5.2 | |||
| SbistSdram | 1.3.6.1.4.1.2.3.51.2.2.5.2.1 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated MM BIST DRAM test result. NOTE: This Mib object is deprecated and no longer supported.
| ||||
| SbistRs485Port1 | 1.3.6.1.4.1.2.3.51.2.2.5.2.2 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST RS 485 legacy test result.
| ||||
| SbistRs485Port2 | 1.3.6.1.4.1.2.3.51.2.2.5.2.3 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST RS 485 local bus test result.
| ||||
| SbistNvram | 1.3.6.1.4.1.2.3.51.2.2.5.2.4 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated MM BIST NVRAM test result. NOTE: This Mib object is deprecated and no longer supported.
| ||||
| SbistRtc | 1.3.6.1.4.1.2.3.51.2.2.5.2.5 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST Real Time Clock test result.
| ||||
| SbistLocalI2CBus | 1.3.6.1.4.1.2.3.51.2.2.5.2.7 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST Local I2C bus test result.
| ||||
| SbistPrimaryMainAppFlashImage | 1.3.6.1.4.1.2.3.51.2.2.5.2.8 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST Primary Main Application Firmware test result.
| ||||
| SbistSecondaryMainAppFlashImage | 1.3.6.1.4.1.2.3.51.2.2.5.2.9 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST Secondary Main Application test result.
| ||||
| SbistBootRomFlashImage | 1.3.6.1.4.1.2.3.51.2.2.5.2.10 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST Boot Firmware test result.
| ||||
| SbistEthernetPort1 | 1.3.6.1.4.1.2.3.51.2.2.5.2.11 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST external ethernet port test result.
| ||||
| SbistEthernetPort2 | 1.3.6.1.4.1.2.3.51.2.2.5.2.12 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated MM BIST internal ethernet port test result. NOTE: This Mib object is deprecated and no longer supported.
| ||||
| SbistInternalPCIBus | 1.3.6.1.4.1.2.3.51.2.2.5.2.13 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated MM BIST PCI bus test result. NOTE: This Mib object is deprecated and no longer supported.
| ||||
| SbistExternalI2CDevices | 1.3.6.1.4.1.2.3.51.2.2.5.2.14 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST external I2C devices test result.
| ||||
| SbistUSBController | 1.3.6.1.4.1.2.3.51.2.2.5.2.15 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated MM BIST USB controller test result. NOTE: This Mib object is deprecated and no longer supported.
| ||||
| SbistVideoCompressorBoard | 1.3.6.1.4.1.2.3.51.2.2.5.2.16 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated MM BIST Video Compressor Board test result. NOTE: This Mib object is deprecated and no longer supported.
| ||||
| SbistRemoteVideo | 1.3.6.1.4.1.2.3.51.2.2.5.2.17 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated MM BIST Remote Video test result. NOTE: This Mib object is deprecated and no longer supported.
| ||||
| SbistPrimaryBus | 1.3.6.1.4.1.2.3.51.2.2.5.2.18 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST primary mid-plane bus test result.
| ||||
| SbistInternalEthernetSwitch | 1.3.6.1.4.1.2.3.51.2.2.5.2.19 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST internal external switch test result.
| ||||
| SbistVideoCapture | 1.3.6.1.4.1.2.3.51.2.2.5.2.20 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST video capture test result.
| ||||
| SbistUSBKeyboardMouseEmulation | 1.3.6.1.4.1.2.3.51.2.2.5.2.21 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST USB keyboard and mouse test result.
| ||||
| SbistUSBMassStorageEmulation | 1.3.6.1.4.1.2.3.51.2.2.5.2.22 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST mass storage emulation test result.
| ||||
| SbistUSBKeyboardMouseFirmware | 1.3.6.1.4.1.2.3.51.2.2.5.2.23 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST USB keyboard and mouse firmware test result.
| ||||
| SbistUSBMassStorageFirmware | 1.3.6.1.4.1.2.3.51.2.2.5.2.24 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST USB keyboard mouse firmware test result.
| ||||
| SbistPrimaryCore | 1.3.6.1.4.1.2.3.51.2.2.5.2.25 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST primary core test result.
| ||||
| SbistSecondaryCore | 1.3.6.1.4.1.2.3.51.2.2.5.2.26 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST secondary core test result.
| ||||
| SbistInternalIOExpander | 1.3.6.1.4.1.2.3.51.2.2.5.2.27 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST internal IO expander test result.
| ||||
| SbistRemoteControlFirmware | 1.3.6.1.4.1.2.3.51.2.2.5.2.28 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST Remote Control firmware test result.
| ||||
| SbistPhysicalNetworkLink | 1.3.6.1.4.1.2.3.51.2.2.5.2.29 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST Physical Network Link test result.
| ||||
| SbistLogicalNetworkLink | 1.3.6.1.4.1.2.3.51.2.2.5.2.30 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory MM BIST Logical Network Link test result.
| ||||
| SbistBladesInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.33 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | ||||
| SbistBladesCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.2.49 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The blades that are communicating on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | ||||
| SbistBlowersInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.65 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The blowers that are installed on the chassis. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| SbistBlowersFunctional | 1.3.6.1.4.1.2.3.51.2.2.5.2.73 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The blowers installed on the chassis that are functional. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed and functional in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed and functional only in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| SbistMediaTrayInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.74 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether a media tray is installed on the chassis.
| ||||
| SbistMediaTrayCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.2.75 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether a media tray is communicating.
| ||||
| SbistOtherMMInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.76 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether a redundant MM is installed.
| ||||
| SbistOtherMMCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.2.77 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether a redundant MM is communicating.
| ||||
| SbistPowerModulesInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.81 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'. | ||||
| SbistPowerModulesFunctional | 1.3.6.1.4.1.2.3.51.2.2.5.2.89 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The power modules that are functional on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed and functioning in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'. | ||||
| SbistSwitchModulesInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.2.97 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011' for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT. | ||||
| SbistSwitchModulesCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.2.113 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The switch modules that are communicating on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed and functioning in bays 1 and 3, and 4 switch modules are supported, the string would look like for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT. | ||||
| SbistLastUpdate | 1.3.6.1.4.1.2.3.51.2.2.5.2.200 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory It is the time when the primary MM updated the last BIST results. | ||||
| NrmmBistAndChassisStatus | 1.3.6.1.4.1.2.3.51.2.2.5.3 | |||
| SrbistRs485Port1 | 1.3.6.1.4.1.2.3.51.2.2.5.3.2 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST RS 485 legacy test result. The time of the last update can be obtained by querying rbistUpdateTime object.
| ||||
| SrbistRs485Port2 | 1.3.6.1.4.1.2.3.51.2.2.5.3.3 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST RS 485 local bus test result. The time of the last update can be obtained by querying rbistUpdateTime object.
| ||||
| SrbistRtc | 1.3.6.1.4.1.2.3.51.2.2.5.3.5 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST Real Time Clock test result. The time of the last update can be obtained by querying rbistUpdateTime object.
| ||||
| SrbistLocalI2CBus | 1.3.6.1.4.1.2.3.51.2.2.5.3.7 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST Local I2C bus test result. The time of the last update can be obtained by querying rbistUpdateTime object.
| ||||
| SrbistPrimaryMainAppFlashImage | 1.3.6.1.4.1.2.3.51.2.2.5.3.8 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST Primary Main Application Firmware test result. The time of the last update can be obtained by querying rbistUpdateTime object.
| ||||
| SrbistSecondaryMainAppFlashImage | 1.3.6.1.4.1.2.3.51.2.2.5.3.9 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST Secondary Main Application test result. The time of the last update can be obtained by querying rbistUpdateTime object.
| ||||
| SrbistBootRomFlashImage | 1.3.6.1.4.1.2.3.51.2.2.5.3.10 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST Boot Firmware test result. The time of the last update can be obtained by querying rbistUpdateTime object.
| ||||
| SrbistEthernetPort1 | 1.3.6.1.4.1.2.3.51.2.2.5.3.11 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST external ethernet port test result. The time of the last update can be obtained by querying rbistUpdateTime object.
| ||||
| SrbistExternalI2CDevices | 1.3.6.1.4.1.2.3.51.2.2.5.3.14 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST external I2C devices test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
| ||||
| SrbistInternalEthernetSwitch | 1.3.6.1.4.1.2.3.51.2.2.5.3.19 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST internal external switch test result. The time of the last update can be obtained by querying rbistUpdateTime object.
| ||||
| SrbistVideoCapture | 1.3.6.1.4.1.2.3.51.2.2.5.3.20 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST video capture test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
| ||||
| SrbistUSBKeyboardMouseEmulation | 1.3.6.1.4.1.2.3.51.2.2.5.3.21 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST USB keyboard and mouse test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
| ||||
| SrbistUSBMassStorageEmulation | 1.3.6.1.4.1.2.3.51.2.2.5.3.22 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST mass storage emulation test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
| ||||
| SrbistUSBKeyboardMouseFirmware | 1.3.6.1.4.1.2.3.51.2.2.5.3.23 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST USB keyboard and mouse firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
| ||||
| SrbistUSBMassStorageFirmware | 1.3.6.1.4.1.2.3.51.2.2.5.3.24 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST USB keyboard mouse firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
| ||||
| SrbistPrimaryCore | 1.3.6.1.4.1.2.3.51.2.2.5.3.25 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST primary core test result. The time of the last update can be obtained by querying rbistUpdateTime object.
| ||||
| SrbistSecondaryCore | 1.3.6.1.4.1.2.3.51.2.2.5.3.26 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST secondary core test result. The time of the last update can be obtained by querying rbistUpdateTime object.
| ||||
| SrbistInternalIOExpander | 1.3.6.1.4.1.2.3.51.2.2.5.3.27 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST internal IO expander test result. The time of the last update can be obtained by querying rbistUpdateTime object.
| ||||
| SrbistRemoteControlFirmware | 1.3.6.1.4.1.2.3.51.2.2.5.3.28 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST Remote Control firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
| ||||
| SrbistPhysicalNetworkLink | 1.3.6.1.4.1.2.3.51.2.2.5.3.29 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST Physical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
| ||||
| SrbistLogicalNetworkLink | 1.3.6.1.4.1.2.3.51.2.2.5.3.30 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Standby MM BIST Logical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
| ||||
| SrbistBladesInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.33 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The blades that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | ||||
| SrbistBladesCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.3.49 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The blades that were communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | ||||
| SrbistBlowersInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.65 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The blowers that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| SrbistBlowersFunctional | 1.3.6.1.4.1.2.3.51.2.2.5.3.73 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The blowers installed on the chassis that were functional when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed and functional in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed and functional only in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| SrbistMediaTrayInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.74 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether a media tray was installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
| ||||
| SrbistMediaTrayCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.3.75 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether a media tray was communicating when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
| ||||
| SrbistOtherMMInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.76 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether a standby MM was installed when the standby MM was once primary.The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
| ||||
| SrbistOtherMMCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.3.77 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether a standby MM was communicating when the standby MM was once primary. The time of the last update can be gotten from the object 'rbistUpdateTimePrimary'.
| ||||
| SrbistPowerModulesInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.81 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The power modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'. | ||||
| SrbistPowerModulesFunctional | 1.3.6.1.4.1.2.3.51.2.2.5.3.89 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The power modules that were functional on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed and functioning in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'. | ||||
| SrbistSwitchModulesInstalled | 1.3.6.1.4.1.2.3.51.2.2.5.3.97 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The switch modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed in bays 1 and 3, and 4 switch modules were supported, the string would look like '1011' for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT. | ||||
| SrbistSwitchModulesCommunicating | 1.3.6.1.4.1.2.3.51.2.2.5.3.113 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The switch modules that are communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed and functioning in bays 1 and 3, and 4 switch modules were supported, the string would look like for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT. | ||||
| SrbistUpdateTime | 1.3.6.1.4.1.2.3.51.2.2.5.3.200 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory It is the time when the standby MM updated the last BIST results. | ||||
| SrbistLastUpdatePrimary | 1.3.6.1.4.1.2.3.51.2.2.5.3.201 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory It is the time when the standby MM updated the last BIST results when it was still primary. | ||||
| NfanPack | 1.3.6.1.4.1.2.3.51.2.2.6 | |||
| TfanPackTable | 1.3.6.1.4.1.2.3.51.2.2.6.1 | NA | mandatory | |
table · not-accessible · mandatory Table of fan pack information. Contains the information for each fan pack. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | ||||
| RfanPackEntry | 1.3.6.1.4.1.2.3.51.2.2.6.1.1 | NA | mandatory | |
| CfanPackIndex | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Fan Pack sequence index. | ||||
| CfanPackExists | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the fan pack specified exists or not.
| ||||
| CfanPackState | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The health state for the fan pack. 0 = unknown, 1 = good, 2 = warning, 3 = bad.
| ||||
| CfanPackFanCount | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The number of fans in the fan pack.
| ||||
| CfanPackAverageSpeed | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The average speed of all fans in the fan pack expressed in percent(%) of maximum RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | ||||
| CfanPackAverageSpeedRPM | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The average speed of all fans in the fan pack expressed in RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | ||||
| CfanPackControllerState | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The health state for the controller for the fan pack. 0 = operational, 1 = flashing in progress, 2 = not present, 3 = communication error, 255 = unknown
| ||||
| NsystemHealth | 1.3.6.1.4.1.2.3.51.2.2.7 | |||
| SsystemHealthStat | 1.3.6.1.4.1.2.3.51.2.2.7.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates status of system health for the system in which the MM resides. Value of 'critical' indicates a severe error has occurred and the system may not be functioning. A value of 'nonCritical' indicates that a error has occurred but the system is currently functioning properly. A value of 'systemLevel' indicates that a condition has occurred that may change the state of the system in the future but currently the system is working properly. A value of 'normal' indicates that the system is operating normally.
| ||||
| TsystemHealthSummaryTable | 1.3.6.1.4.1.2.3.51.2.2.7.2 | NA | mandatory | |
table · not-accessible · mandatory Table of System Health summary. Contains more detailed information about the reasons for the overall system health status. NOTE: This MIB object is for BladeCenter only. | ||||
| RsystemHealthSummaryEntry | 1.3.6.1.4.1.2.3.51.2.2.7.2.1 | NA | mandatory | |
row · not-accessible · mandatory System Health Summary entry NOTE: This MIB object is for BladeCenter only. | ||||
| CsystemHealthSummaryIndex | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory System health summary index. NOTE: This MIB object is for BladeCenter only. | ||||
| CsystemHealthSummarySeverity | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory System health summary severity. NOTE: This MIB object is for BladeCenter only. | ||||
| CsystemHealthSummaryDescription | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory System health summary description. NOTE: This MIB object is for BladeCenter only. | ||||
| CsystemHealthSummaryDateTime | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory System health summary date time. NOTE: This MIB object is for BladeCenter only. | ||||
| Nleds | 1.3.6.1.4.1.2.3.51.2.2.8 | |||
| NfrontPanelLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.1 | |||
| SsystemErrorLED | 1.3.6.1.4.1.2.3.51.2.2.8.1.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether the front panel system error LED is on or off. NOTE: This MIB object is for BladeCenter only.
| ||||
| SinformationLED | 1.3.6.1.4.1.2.3.51.2.2.8.1.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Indicates whether the front panel system information LED is on or off. For Write access, the LED can be turned off only. NOTE: This MIB object is for BladeCenter only.
| ||||
| StemperatureLED | 1.3.6.1.4.1.2.3.51.2.2.8.1.3 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether the front panel temperature LED is on or off. NOTE: This MIB object is for BladeCenter only.
| ||||
| SidentityLED | 1.3.6.1.4.1.2.3.51.2.2.8.1.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Indicates whether the front panel identity LED is on or off. NOTE: This MIB object is for BladeCenter only.
| ||||
| NbladeLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.2 | |||
| TbladeLEDsTable | 1.3.6.1.4.1.2.3.51.2.2.8.2.1 | NA | mandatory | |
table · not-accessible · mandatory Table of blade status information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more. | ||||
| RbladeLEDsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1 | NA | mandatory | |
| CledBladeIndex | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade LED table index. | ||||
| CledBladeId | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CledBladeExists | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CledBladePowerState | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified.
| ||||
| CledBladeHealthState | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
| ||||
| CledBladeName | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CledBladeSystemError | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blade system error LED is on or off.
| ||||
| CledBladeInformation | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Indicates whether the blade information LED is on or off. For Write access, the LED can be turned off only.
| ||||
| CledBladeKVM | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blade KVM LED is on, off, or blinking.
| ||||
| CledBladeMediaTray | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blade media tray LED is on, off, or blinking.
| ||||
| CledBladeIdentity | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.11 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Indicates whether the blade identify LED is on, off, or blinking.
| ||||
| TbladeLEDsDetailsTable | 1.3.6.1.4.1.2.3.51.2.2.8.2.2 | NA | mandatory | |
table · not-accessible · mandatory Table of blade LEDs detailed information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more. | ||||
| RbladeLEDsDetailsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1 | NA | mandatory | |
| CledIndex | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The LED index number. For consistent results, view as a table and not as individual entries. | ||||
| CledBladeBayNumber | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The bay number of the main server blade that the LED is grouped into. For consistent results, view as a table and not as individual entries. | ||||
| CledBladeComponentType | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Type of the component/subcomponent grouping for this LED. For consistent results, view as a table and not as individual entries. | ||||
| CledBladeLabel | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Text label for a LED. For consistent results, view as a table and not as individual entries. | ||||
| CledBladeState | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Text description which denotes color or on/off/blink state for a LED. For consistent results, view as a table and not as individual entries.
| ||||
| CledBladeLocation | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Location of this LED. For consistent results, view as a table and not as individual entries. | ||||
| NtelcoPanelLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.3 | |||
| ScriticalLED | 1.3.6.1.4.1.2.3.51.2.2.8.3.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether the BladeCenter T Panel CRT (Critical) LED is on or off. NOTE: This MIB object is for BladeCenter T only.
| ||||
| SmajorLED | 1.3.6.1.4.1.2.3.51.2.2.8.3.2 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether the BladeCenter T Panel MJR (Major) LED is on or off. NOTE: This MIB object is for BladeCenter T only.
| ||||
| SminorLED | 1.3.6.1.4.1.2.3.51.2.2.8.3.3 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether the BladeCenter T Panel MNR (Minor) LED is on or off. NOTE: This MIB object is for BladeCenter T only.
| ||||
| StelcoIdentityLED | 1.3.6.1.4.1.2.3.51.2.2.8.3.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Indicates whether the BladeCenter T Panel identity LED is on or off. NOTE: This MIB object is for BladeCenter T only.
| ||||
| StelcoColorSel | 1.3.6.1.4.1.2.3.51.2.2.8.3.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Indicates whether the BladeCenter T Critical and Major LEDs are displayed in amber or red color. NOTE: This MIB object is for BladeCenter T only.
| ||||
| ScriticalityAssertionMode | 1.3.6.1.4.1.2.3.51.2.2.8.3.6 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Indicates whether the BladeCenter T Criticality Assertion Mode is enabled or disabled. NOTE: This MIB object is for BladeCenter T only.
| ||||
| NsmLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.4 | |||
| TsmLEDsTable | 1.3.6.1.4.1.2.3.51.2.2.8.4.1 | NA | mandatory | |
table · not-accessible · mandatory Table of switch module LEDs information. | ||||
| RsmLEDsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.4.1.1 | NA | mandatory | |
| CledSMIndex | 1.3.6.1.4.1.2.3.51.2.2.8.4.1.1.1 | INTEGER (0..128) | RO | mandatory |
column · INTEGER (0..128) · read-only · mandatory Switch module LEDs table index. | ||||
| CledSMLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.4.1.1.2 | OCTET STRING (SIZE (256)) | RO | mandatory |
column · OCTET STRING (SIZE (256)) · read-only · mandatory A bitmap of LEDs information on the selected switch module. The bitmap is a string containing a list of 1's and 0's. Every 4 bytes are used to represent a led state. The first 64 bytes represent the status of the external LEDs while the last 64 bytes represent the status of the internal port connections from the switch module to blades. Each nibble of data is presented in the bitmap format (0000) and is encoded as followed - 0000: LED is not present - 0001: LED is off - 0010: LED is on NOTE: The data is read from left to right, starting out with blade server 1 and so on. | ||||
| NblowerLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.5 | |||
| TblowerLEDsTable | 1.3.6.1.4.1.2.3.51.2.2.8.5.1 | NA | mandatory | |
table · not-accessible · mandatory Table of blower LEDs information. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| RblowerLEDsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1 | NA | mandatory | |
| CledBlowerIndex | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.1 | INTEGER (0..128) | RO | mandatory |
column · INTEGER (0..128) · read-only · mandatory Blower LEDs table index. | ||||
| CledBlowerId | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CledBlowerExists | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blower specified exists or not.
| ||||
| CledBlowerError | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blower error LED is on, off, or not available.
| ||||
| NfanPackLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.6 | |||
| TfanPackLEDsTable | 1.3.6.1.4.1.2.3.51.2.2.8.6.1 | NA | mandatory | |
table · not-accessible · mandatory Table of fan pack LEDs information. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | ||||
| RfanPackLEDsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1 | NA | mandatory | |
| CledFanPackIndex | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.1 | INTEGER (0..128) | RO | mandatory |
column · INTEGER (0..128) · read-only · mandatory Fan Pack LEDs table index. | ||||
| CledFanPackId | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric fan pack ID.
| ||||
| CledFanPackExists | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.3 | INTEGER (0..128) | RO | mandatory |
column · INTEGER (0..128) · read-only · mandatory Indicates whether the fan pack specified exists or not. | ||||
| CledFanPackError | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.4 | INTEGER (0..128) | RO | mandatory |
column · INTEGER (0..128) · read-only · mandatory Indicates whether the fan pack error LED is on or off. | ||||
| NmtStatusLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.7 | |||
| TmtStatusLEDsTable | 1.3.6.1.4.1.2.3.51.2.2.8.7.1 | NA | mandatory | |
table · not-accessible · mandatory Table of Media Tray Status LEDs information. NOTE: This MIB object is for BladeCenter HT only. | ||||
| RmtStatusLEDsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.7.1.1 | NA | mandatory | |
row · not-accessible · mandatory Media Tray Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CledMediaTrayIndex | 1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.1 | INTEGER (0..128) | RO | mandatory |
column · INTEGER (0..128) · read-only · mandatory Media Tray Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CledMediaTrayId | 1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric Media Tray ID. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CledMediaTrayExists | 1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the Media Tray exists or not. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CledMediaTrayFault | 1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the Media Tray Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| NtapStatusLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.8 | |||
| StapExists | 1.3.6.1.4.1.2.3.51.2.2.8.8.3 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether the Alarm Panel exists or not. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| StapFRRLED | 1.3.6.1.4.1.2.3.51.2.2.8.8.4 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether the Alarm Panel Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| StapFaultLED | 1.3.6.1.4.1.2.3.51.2.2.8.8.5 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether the Alarm Panel Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| NncStatusLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.9 | |||
| TncStatusLEDsTable | 1.3.6.1.4.1.2.3.51.2.2.8.9.1 | NA | deprecated | |
table · not-accessible · deprecated Table of Network Clock Status LEDs information. NOTE: This MIB object is for BladeCenter HT only. | ||||
| RncStatusLEDsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.9.1.1 | NA | deprecated | |
row · not-accessible · deprecated Network Clock Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CledNetworkClockIndex | 1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.1 | INTEGER (0..128) | RO | deprecated |
column · INTEGER (0..128) · read-only · deprecated Network Clock Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CledNetworkClockId | 1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.2 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated The numeric Network Clock ID. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CledNetworkClockExists | 1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.3 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Indicates whether the Network Clock exists or not. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CledNetworkClockFRR | 1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.4 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Indicates whether the Network Clock Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CledNetworkClockFault | 1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.5 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Indicates whether the Network Clock Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| NmxStatusLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.10 | |||
| TmxStatusLEDsTable | 1.3.6.1.4.1.2.3.51.2.2.8.10.1 | NA | mandatory | |
table · not-accessible · mandatory Table of Multiplexer Expansion Module Status LEDs information. NOTE: This MIB object is for BladeCenter HT only. | ||||
| RmxStatusLEDsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.10.1.1 | NA | mandatory | |
row · not-accessible · mandatory Multiplexer Expansion Module Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CledMuxIndex | 1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.1 | INTEGER (0..128) | RO | mandatory |
column · INTEGER (0..128) · read-only · mandatory Multiplexer Expansion Module Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CledMuxId | 1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric Multiplexer Expansion Module ID. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CledMuxExists | 1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the Multiplexer Expansion Module exists or not. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CledMuxFRR | 1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the Multiplexer Expansion Module Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CledMuxFault | 1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the Multiplexer Expansion Module Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| NstorageLEDs | 1.3.6.1.4.1.2.3.51.2.2.8.11 | |||
| TstorageLEDsTable | 1.3.6.1.4.1.2.3.51.2.2.8.11.1 | NA | mandatory | |
table · not-accessible · mandatory Table of storage module LEDs information. NOTE: This MIB object is for BladeCenter S only. | ||||
| RstorageLEDsEntry | 1.3.6.1.4.1.2.3.51.2.2.8.11.1.1 | NA | mandatory | |
row · not-accessible · mandatory Storage Module LEDs information entry NOTE: This MIB object is for BladeCenter S only.
| ||||
| CledStorageIndex | 1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Storage Module LEDs table index. NOTE: This MIB object is for BladeCenter S only. | ||||
| CledStorageId | 1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric storage module ID. NOTE: This MIB object is for BladeCenter S only.
| ||||
| CledStorageExists | 1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the storage module specified exists or not. NOTE: This MIB object is for BladeCenter S only.
| ||||
| CledStorageError | 1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the status of the storage module error LED. NOTE: This MIB object is for BladeCenter S only.
| ||||
| NtelcoSystemHealth | 1.3.6.1.4.1.2.3.51.2.2.9 | |||
| StelcoSystemHealthStat | 1.3.6.1.4.1.2.3.51.2.2.9.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates status of system health for the system in which the MM resides. Value of 'critical' indicates a non-recoverable service affecting condition has occurred that requires an immediate action. A value of 'major' indicates a critical service affecting condition has occurred that requires an urgent action. A value of 'minor' indicates a non-service affecting condition has occurred. Corrective action should be taken in order to prevent a more serious fault. A value of 'normal' indicates that the system is operating normally. Severity level with '-power' indicates the failure relates to the power resource. NOTE: This MIB object is for BladeCenter T only.
| ||||
| TtelcoSystemHealthSummaryTable | 1.3.6.1.4.1.2.3.51.2.2.9.2 | NA | mandatory | |
table · not-accessible · mandatory Table of System Health summary. Contains more detailed
information about the reasons for the overall system
health status.
NOTE: This MIB object is for BladeCenter T only.
NOTE: This table may contain one entry if no alarms are in progress. That one entry,
if present, contains no alarms but a message of 'Good' in the severity object. | ||||
| RtelcoSystemHealthSummaryEntry | 1.3.6.1.4.1.2.3.51.2.2.9.2.1 | NA | mandatory | |
row · not-accessible · mandatory BladeCenter T System Health Summary entry. NOTE: This MIB object is for BladeCenter T only. | ||||
| CtelcoSystemHealthSummaryIndex | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory BladeCenter T System Health Summary Index. NOTE: This MIB object is for BladeCenter T only. | ||||
| CtelcoSystemHealthSummarySeverity | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory BladeCenter T System Health Summary Severity. The values and meanings are as follows: 0x06 Critical-Power 0x05 Critical 0x04 Major-Power 0x03 Major 0x02 Minor-Power 0x01 Minor 0xFF Normal NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'Good'. | ||||
| CtelcoSystemHealthSummaryDescription | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory BladeCenter T System Health Summary Description. NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'No alarm events'. | ||||
| CtelcoSystemHealthSummaryEventName | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory BladeCenter T System Health Summary Event Name. NOTE: This MIB object is for BladeCenter T only. | ||||
| CtelcoSystemHealthSummaryEventKeyID | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory BladeCenter T System Health Summary Event Key ID. An octet string
expressed as 'mmm:ggg:iii:aaa:sss' where:
m : Module ID value of decimal digits(1-255) or
blank space(s) for leading zero(s)
g : Gen ID value of decimal digits(1-255) or
blank space(s) for leading zero(s)
i : GenInfo ID value of decimal digits(1-255) or
blank space(s) for leading zero(s)
a : Alarm ID value of decimal digits(1-255) or
blank space(s) for leading zero(s)
s : Alarm severity value of decimal digits(1-255) or
blank space(s) for leading zero(s)
NOTE: This MIB object is for BladeCenter T only.
NOTE: If no alarms are in progress, this object contains 'No alarm events'. | ||||
| CtelcoSystemHealthSummaryAcknowledge | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.6 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory BladeCenter T System Health Summary Acknowledge. Indicates whether the alarm event is acknowledged or unacknowledged. NOTE: This MIB object is for BladeCenter T only.
| ||||
| CtelcoSystemHealthSummaryAssertTime | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory BladeCenter T System Health Summary Assert Time. NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'No alarm events'. | ||||
| NfuelGauge | 1.3.6.1.4.1.2.3.51.2.2.10 | |||
| NfuelGaugeInformation | 1.3.6.1.4.1.2.3.51.2.2.10.1 | |||
| TfuelGaugeTable | 1.3.6.1.4.1.2.3.51.2.2.10.1.1 | NA | mandatory | |
table · not-accessible · mandatory Table of Fuel Gauge information. | ||||
| RfuelGaugeEntry | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1 | NA | mandatory | |
| CfuelGaugeIndex | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Fuel Gauge Table Index. | ||||
| CfuelGaugePowerDomainNumber | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Fuel Gauge Table Power Domain Number.
| ||||
| CfuelGaugeStatus | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Fuel Gauge Table Status for the power domain. The response will start out with a numeric value (0 = unknown, 1 = good, 2 = warning, and 3: bad), followed by a text message. | ||||
| CfuelGaugeFirstPowerModule | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Fuel Gauge Table First Power Module capacity in Watts in the power domain. NOTE: First power module in power domain 1 and 2 is in bay 1 and 3 respectively. | ||||
| CfuelGaugeSecondPowerModule | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Fuel Gauge Table Second Power Module capacity in Watts in the power domain. NOTE: Second power module in power domain 1 and 2 is in bay 2 and 4 respectively. | ||||
| CfuelGaugePowerManagementPolicySetting | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.6 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Fuel Gauge Table for the Power Management Policy Setting for each power domain.
When a 1200W or 1400W power module is installed in the domain
the power management policy will not be applicable.
In addition the power consumption in this domain will not be monitored.
A new powerPolicyTable has been added which provides more detailed
information regarding a domains power policy information. This table
also has the capability to SET the power policy for a given domain.
In addition, note that the first three enumerated choices above are
referred to with updated nomenclature, as follows:
redundantWithoutPerformanceImpact(0) equals Redundant Power Modules
redundantWithPerformanceImpact(1) equals Power Modules with Blade
Throttling Allowed
nonRedundant(2) equals Basic Power Management
| ||||
| CfuelGaugeTotalPower | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory This field displays the total available power for each power domain based on installed power modules and the current Power Management Policy Setting. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. | ||||
| CfuelGaugeAllocatedPower | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory This field displays the power that has been reserved in each power domain. NOTE: 1) Power is always reserved in domain 1 for two management modules and two I/O modules. 2) Power is reserved for I/O modules installed in bay 3 and 4 (Powered on or standby). 3) Power is reserved for each installed Blade. Blades in a standby state (not powered on) will reserve a certain amount power. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. | ||||
| CfuelGaugeRemainingPower | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory This field displays the remaining power available in each domain. Remaining Power = Total Power minus Power In Use When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. | ||||
| CfuelGaugePowerInUsed | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory This field displays the total power being used in each power domain. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. | ||||
| NpowerDomain1 | 1.3.6.1.4.1.2.3.51.2.2.10.2 | |||
| TpowerDomain1Table | 1.3.6.1.4.1.2.3.51.2.2.10.2.1 | NA | mandatory | |
table · not-accessible · mandatory Table of Power Domain 1. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | ||||
| RpowerDomain1Entry | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1 | NA | mandatory | |
| Cpd1Index | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 1 Table Index. | ||||
| Cpd1BayNumber | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 1 Table Bay Number. The following Bay Number IDs are used in the BladeCenter: notApplicable(1), notApplicable(2), blowerBay1(3), blowerBay2(4), managementModuleBay1(5), managementModuleBay2(6), switchModuleBay1(7), switchModuleBay2(8), switchModuleBay3(9), switchModuleBay4(10), serverBladeBay1(11), serverBladeBay2(12), serverBladeBay3(13), serverBladeBay4(14), serverBladeBay5(15), serverBladeBay6(16), notApplicable(17) The following Bay Number IDs are used in the BladeCenter H: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), managementModuleBay1(7), managementModuleBay2(8), ioModuleBay1(9), ioModuleBay2(10), ioModuleBay3(11), ioModuleBay4(12), ioModuleBay7(13), ioModuleBay8(14), ioModuleBay9(15), ioModuleBay10(16), serverBladeBay1(17), serverBladeBay2(18), serverBladeBay3(19), serverBladeBay4(20), serverBladeBay5(21), serverBladeBay6(22), serverBladeBay7(23), notApplicable(24) The following Bay Number IDs are used in the BladeCenter T: notApplicable(1), notApplicable(2), blowerBay1(3), blowerBay2(4), blowerBay3(5) (if Power Domain 2 is not available), blowerBay4(6) (if Power Domain 2 is not available), managementModuleBay1(7), managementModuleBay2(8), switchModuleBay1(9), switchModuleBay2(10), switchModuleBay3(11), switchModuleBay4(12), serverBladeBay1(13), serverBladeBay2(14), serverBladeBay3(15), serverBladeBay4(16), notApplicable(17) The following Bay Number IDs are used in the BladeCenter HT: notApplicable(1), mediatrayBay1(2), mediatrayBay2(3), fanPackBay1(4), fanPackBay2(5), fanPackBay3(6), fanPackBay4(7), blowerBay1(8), blowerBay2(9), blowerBay3(10), blowerBay4(11), networkclockBay1(12), networkclockBay2(13), midplaneelectroBay1(14), midplaneelectroBay2(15), notApplicable(16), managementModuleBay1(17), managementModuleBay2(18), ioModuleBay1(19), ioModuleBay2(20), ioModuleBay3(21), ioModuleBay4(22), serverBladeBay1(23), serverBladeBay2(24), serverBladeBay3(25), serverBladeBay4(26), serverBladeBay5(27), serverBladeBay6(28), notApplicable(29) The following Bay Number IDs are used in the BladeCenter S: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), blowerBay1(7), blowerBay2(8), blowerBay3(9), blowerBay4(10), storageModuleBay1(11), storageModuleBay2(12), managementModuleBay(13), ioModuleBay1(14), ioModuleBay2(15), ioModuleBay3(16), ioModuleBay4(17), serverBladeBay1(18), serverBladeBay2(19), serverBladeBay3(20), serverBladeBay4(21), serverBladeBay5(22), serverBladeBay6(23), notApplicable(24) | ||||
| Cpd1BladePrimarySlot | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 1 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not.
| ||||
| Cpd1ModuleStatus | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 1 Table Module Throttle Status.
| ||||
| Cpd1ModuleName | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 1 Table Module Name. | ||||
| Cpd1ModuleState | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.6 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 1 Table Module State.
| ||||
| Cpd1ModuleAllocatedPowerCurrent | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 1 Table Allocated Power Current indicates the current power allocation for the module in Watts. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the current power allocation for the module is equally divided among the slots. | ||||
| Cpd1ModuleAllocatedPowerMax | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 1 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the module will consume in the domain when it is fully populated with memory chips, expansion cards, etc. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the maximum power allocation for the module is equally divided among the slots. | ||||
| Cpd1ModuleAllocatedPowerMin | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 1 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of the component in the domain based on its maximum throttle limit. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the minimum power allocation for the module is equally divided among the slots. | ||||
| Cpd1ModuleCPUDutyCycles | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 1 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that some blades do not report the CPU duty cycles. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The CPU duty cycles are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The CPU duty cycles are reported on slot 3 while 'notApplicable' is displayed for slot 4. | ||||
| Cpd1ModuleThrottle | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 1 Table Module Throttle indicates whether the server blade may be allowed to throttle or not. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored.
| ||||
| Cpd1ModulePowerCapabilities | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 1 Table Module Power Capabilities.
staticPowerManagement: the module with the static worst
case power values.
fixedPowermanagement: the module with the static power values but
ability to throttle.
dynamicPowerManagement: the module with power meter capability,
measurement enabled, but capping disabled.
dynamicPowerMeasurement1: the module with power meter capability,
measurement enabled, phase 1 only
dynamicPowerMeasurement2: the module with power meter capability,
measurement enabled, phase 2 or higher
dynamicPowerMeasurementWithPowerCapping: the module with power
meter capability, both measurement and capping enabled,
phase 2 or higher
| ||||
| Cpd1ModuleMeasuredOrStatic | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.13 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 1 Table Module Measured Or Static.
| ||||
| NpowerDomain1PowerTrending | 1.3.6.1.4.1.2.3.51.2.2.10.2.3 | |||
| Spd1PowerTrendingPeriod | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Specify time period for power domain 1 power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Power Domain.
| ||||
| Tpd1PowerTrendingSampleTable | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10 | NA | mandatory | |
table · not-accessible · mandatory Table of Power Domain 1 Power Trending Information. | ||||
| Rpd1PowerTrendingSampleEntry | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1 | NA | mandatory | |
row · not-accessible · mandatory Power Domain 1 Power Trending Sample entry. | ||||
| Cpd1PowerTrendingSampleIndex | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 1 Power Trending Sample Table Index. | ||||
| Cpd1PowerTrendingSampleTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 1 Power Trending Sample Table Timestamp. | ||||
| Cpd1PowerTrendingSampleAve | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 1 Power Trending Table Average Power. | ||||
| NpowerDomain2 | 1.3.6.1.4.1.2.3.51.2.2.10.3 | |||
| TpowerDomain2Table | 1.3.6.1.4.1.2.3.51.2.2.10.3.1 | NA | mandatory | |
table · not-accessible · mandatory Table of Power Domain 2. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | ||||
| RpowerDomain2Entry | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1 | NA | mandatory | |
| Cpd2Index | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 2 Table Index. | ||||
| Cpd2BayNumber | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 2 Table Bay Number. The following Bay Number IDs are used in the BladeCenter: serverBladeBay7(1), serverBladeBay8(2), serverBladeBay9(3), serverBladeBay10(4), serverBladeBay11(5), serverBladeBay12(6), serverBladeBay13(7), serverBladeBay14(8), notApplicable(9) The following Bay Number IDs are used in the BladeCenter H: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), managementModuleBay1(7), managementModuleBay2(8), ioModuleBay1(9), ioModuleBay2(10), ioModuleBay3(11), ioModuleBay4(12), ioModuleBay7(13), ioModuleBay8(14), ioModuleBay9(15), ioModuleBay10(16), serverBladeBay8(17), serverBladeBay9(18), serverBladeBay10(19), serverBladeBay11(20), serverBladeBay12(21), serverBladeBay13(22), serverBladeBay14(23), notApplicable(24) The following Bay Number IDs are used in the BladeCenter T: blowerBay3(1), blowerBay4(2), serverBladeBay5(3), serverBladeBay6(4), serverBladeBay7(5), serverBladeBay8(6), notApplicable(7), notApplicable(8), notApplicable(9) The following Bay Number IDs are used in the BladeCenter HT: fanPackBay1(1), fanPackBay2(2), fanPackBay3(3), fanPackBay4(4), blowerBay1(5), blowerBay2(6), blowerBay3(7), blowerBay4(8), ioModuleBay7(9), ioModuleBay8(10), ioModuleBay9(11), ioModuleBay10(12), serverBladeBay7(13), serverBladeBay8(14), serverBladeBay9(15), serverBladeBay10(16), serverBladeBay11(17), serverBladeBay12(18), notApplicable(19) | ||||
| Cpd2BladePrimarySlot | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 2 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not.
| ||||
| Cpd2ModuleStatus | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 2 Table Module throttle status.
| ||||
| Cpd2ModuleName | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 2 Table Module Name. | ||||
| Cpd2ModuleState | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.6 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 2 Table Power State.
| ||||
| Cpd2ModuleAllocatedPowerCurrent | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 2 Table Allocated Power Current indicates the current power allocation for the module. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the current power allocation for the module is equally divided among the slots. | ||||
| Cpd2ModuleAllocatedPowerMax | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 2 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the module will consume in the domain when it is fully populated with memory chips, expansion cards, etc. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the maximum power allocation for the module is equally divided among the slots. | ||||
| Cpd2ModuleAllocatedPowerMin | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 2 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of the component in the domain based on its maximum throttle limit. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the minimum power allocation for the module is equally divided among the slots. | ||||
| Cpd2ModuleCPUDutyCycles | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 2 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that some blades do not report the CPU duty cycles. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The CPU duty cycles are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The CPU duty cycles are reported on slot 3 while 'notApplicable' is displayed for slot 4. | ||||
| Cpd2ModuleThrottle | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 2 Table Module Throttle indicates whether the server blade may be allowed to throttle or not. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored.
| ||||
| Cpd2ModulePowerCapabilities | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 2 Table Module Power Capabilities.
staticPowerManagement: the module with the static worst
case power values.
fixedPowermanagement: the module with the static power values but
ability to throttle.
dynamicPowerManagement: the module with power meter capability,
measurement enabled, but capping disabled.
dynamicPowerMeasurement1: the module with power meter capability,
measurement enabled, phase 1 only
dynamicPowerMeasurement2: the module with power meter capability,
measurement enabled, phase 2 or higher
dynamicPowerMeasurementWithPowerCapping: the module with power
meter capability, both measurement and capping enabled,
phase 2 or higher
| ||||
| Cpd2ModuleMeasuredOrStatic | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.13 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 2 Table Module Measured Or Static.
| ||||
| NpowerDomain2PowerTrending | 1.3.6.1.4.1.2.3.51.2.2.10.3.3 | |||
| Spd2PowerTrendingPeriod | 1.3.6.1.4.1.2.3.51.2.2.10.3.3.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Specify time period for power domain 2 power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Power Domain.
| ||||
| Tpd2PowerTrendingSampleTable | 1.3.6.1.4.1.2.3.51.2.2.10.3.3.10 | NA | mandatory | |
table · not-accessible · mandatory Table of Power Domain 2 Power Trending Sample Information. | ||||
| Rpd2PowerTrendingSampleEntry | 1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1 | NA | mandatory | |
row · not-accessible · mandatory Power Domain 2 Power Trending Sample entry. | ||||
| Cpd2PowerTrendingSampleIndex | 1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power Domain 2 Power Trending Sample Table Index. | ||||
| Cpd2PowerTrendingSampleTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 2 Power Trending Sample Table Timestamp. | ||||
| Cpd2PowerTrendingSampleAve | 1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power Domain 2 Power Trending Sample Table Average Power. | ||||
| NmoduleInformation | 1.3.6.1.4.1.2.3.51.2.2.10.4 | |||
| NbladeDetails | 1.3.6.1.4.1.2.3.51.2.2.10.4.1 | |||
| TbladeDetailsTable | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1 | NA | mandatory | |
table · not-accessible · mandatory Table of Blade Module Details. | ||||
| RbladeDetailsEntry | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1 | NA | mandatory | |
| CbladeDetailsIndex | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade Module Details Table Index. | ||||
| CbladeDetailsId | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade Module Details Table Blade Id.
| ||||
| CbladeDetailsMaxPowerConfig | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Blade Module Details Table Maximum Power Configuration. Allow the user to set the maximum power that can be used by the blade. This function is also known as power capping. If the value of maximum power config is zero, it means the blade doesn't support the power capping feature | ||||
| CbladeDetailsEffectiveClockRate | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade Module Details Table Effective CPU Clock Rate applies to DPM blades only. It displays processor's effective clock rate based on sample interval. Note that some blades do not effective clock rate. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The effective clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The effective clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4. | ||||
| CbladeDetailsMaximumClockRate | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade Module Details Table Maximum CPU Clock Rate applies to DPM blades only. It displays processor's maximum clock rate based on sample interval. Note that some blades do not maximum clock rate. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The maximum clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The maximum clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4. | ||||
| CbladeDetailsPowerSaverMode | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory When enabled, the static low power saver mode allows the blade to selectively alter its operating voltage and frequency to reduce power consumption. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the static low power saver mode, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the static low power saver mode may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsDynamicPowerSaver if its not already disabled.
| ||||
| CbladeDetailsDynamicPowerSaver | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory When enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the blade to be controlled based on how busy the CPU is. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power saver may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsPowerSaverMode if its not already disabled.
| ||||
| CbladeDetailsDynamicPowerFavorPerformanceOverPower | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory When enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the system past its nominal CPU frequency when CPU and memory utilization implies it would help and the system allows it. Dynamic Power Performance Over Power can be active on the blade only after Dynamic Power Saver is enabled. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power favor performance over power may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation.
| ||||
| CbladeDetailsPowerControl | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory This object is used to get or set the power control setting on a blade. If dynamic power mgmt is not supported on a blade, notApplicable(255) will be returned. This will set the power control setting on all slots of the multiwide blade. The same can be used if the blade is single wide.
| ||||
| NbladePowerTrending | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3 | |||
| SbladePowerTrendingPeriod | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Specify time period for blade module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Blade Module.
| ||||
| SbladePowerTrendingBladeId | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Blade Module Power Trending Blade Id. NOTE: The Blade Id should be configured before displaying the bladePowerTrendingTable.
| ||||
| TbladePowerTrendingSampleTable | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10 | NA | mandatory | |
table · not-accessible · mandatory Table of Blade Module Power Trending Information. | ||||
| RbladePowerTrendingSampleEntry | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1 | NA | mandatory | |
row · not-accessible · mandatory Blade Module Power Trending Sample entry. | ||||
| CbladePowerTrendingSampleIndex | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade Module Power Trending Sample Table Index. | ||||
| CbladePowerTrendingSampleId | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade Module Power Trending Sample Table Blade Id.
| ||||
| CbladePowerTrendingSampleTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade Module Power Trending Sample Table Timestamp. | ||||
| CbladePowerTrendingSampleMax | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade Module Power Trending Sample Table Maximum Power. | ||||
| CbladePowerTrendingSampleMin | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade Module Power Trending Sample Table Minimum Power. | ||||
| CbladePowerTrendingSampleAve | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade Module Power Trending Sample Table Average Power. | ||||
| NswitchDetails | 1.3.6.1.4.1.2.3.51.2.2.10.4.2 | |||
| NswitchPowerTrending | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3 | |||
| SswitchPowerTrendingPeriod | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Specify time period for switch module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Switch Module.
| ||||
| SswitchPowerTrendingSwitchId | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Switch Module Power Trending Switch Id. NOTE: The Switch Id should be configured before displaying the switchPowerTrendingTable.
| ||||
| TswitchPowerTrendingSampleTable | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10 | NA | mandatory | |
table · not-accessible · mandatory Table of Switch Module Power Trending Information. | ||||
| RswitchPowerTrendingSampleEntry | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Module Power Trending Sample entry. | ||||
| CswitchPowerTrendingSampleIndex | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module Power Trending Sample Table Index. | ||||
| CswitchPowerTrendingSampleId | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module Power Trending Sample Table Switch Id.
| ||||
| CswitchPowerTrendingSampleTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module Power Trending Sample Table Timestamp. | ||||
| CswitchPowerTrendingSampleMax | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module Power Trending Sample Table Maximum Power. | ||||
| CswitchPowerTrendingSampleMin | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module Power Trending Sample Table Minimum Power. | ||||
| CswitchPowerTrendingSampleAve | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module Power Trending Sample Table Average Power. | ||||
| NblowerDetails | 1.3.6.1.4.1.2.3.51.2.2.10.4.3 | |||
| NblowerPowerTrending | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3 | |||
| SblowerPowerTrendingPeriod | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Specify time period for blower module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Blower Module. NOTE: Blowers are also referred to as Chassis Cooling Devices.
| ||||
| SblowerPowerTrendingBlowerId | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Blower Module Power Trending Blower Id. NOTE: The Blower Id should be configured before displaying the blowerPowerTrendingTable. NOTE: Blowers are also referred to as Chassis Cooling Devices.
| ||||
| TblowerPowerTrendingSampleTable | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10 | NA | mandatory | |
table · not-accessible · mandatory Table of Blower Module Power Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| RblowerPowerTrendingSampleEntry | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1 | NA | mandatory | |
row · not-accessible · mandatory Blower Module Power Trending Sample entry. | ||||
| CblowerPowerTrendingSampleIndex | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blower Module Power Trending Sample Table Index. | ||||
| CblowerPowerTrendingSampleId | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blower Module Power Trending Sample Table Blower Id.
| ||||
| CblowerPowerTrendingSampleTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower Module Power Trending Sample Table Timestamp. | ||||
| CblowerPowerTrendingSampleMax | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower Module Power Trending Sample Table Maximum Power. | ||||
| CblowerPowerTrendingSampleMin | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower Module Power Trending Sample Table Minimum Power. | ||||
| CblowerPowerTrendingSampleAve | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower Module Power Trending Sample Table Average Power. | ||||
| NchassisInformation | 1.3.6.1.4.1.2.3.51.2.2.10.5 | |||
| NchassisConfiguration | 1.3.6.1.4.1.2.3.51.2.2.10.5.1 | |||
| SchassisTotalDCPowerAvailable | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.1 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Chassis total DC power available, which displays the total DC power available for the entire chassis. It is the sum of the two power domains. | ||||
| SchassisTotalACPowerInUsed | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.2 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Chassis total AC power being used, which displays the total AC power being consumed by all modules in the chassis. It also includes power consumed by the blowers (chassis oooling devices) for the chassis. | ||||
| SchassisTotalThermalOutput | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.3 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Chassis total thermal output, which displays the thermal output (load) in BTUs per hour. It is calculated based on the total AC power in use. (1 Watt = 3.412 BTU/hour). | ||||
| SchassisTrendingSampleInterval | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Chassis Power and Thermal Trending Sample Interval. 0 means no trending. the minimum interval is 10 minutes and the maximum is 60 minutes, in 5 minute increments. | ||||
| SchassisPowerService | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.5 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The chassis power service mode. NOTE: This MIB object is for BCS only.
| ||||
| NchassisPowerTrending | 1.3.6.1.4.1.2.3.51.2.2.10.5.3 | |||
| SchassisPowerTrendingPeriod | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Specify time period of power trending information. NOTE: This time period should be configured before displaying the following Power Trending Information table for Chassis.
| ||||
| TchassisPowerTrendingSampleTable | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10 | NA | mandatory | |
table · not-accessible · mandatory Table of Chassis Power Trending Sample Information in specified time period. | ||||
| RchassisPowerTrendingSampleEntry | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1 | NA | mandatory | |
row · not-accessible · mandatory Chassis Power Trending Sample entry in specified time period. | ||||
| CchassisPowerTrendingSampleIndex | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Chassis Power Trending Sample Index in specified time period. | ||||
| CchassisPowerTrendingSampleTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Chassis Power Trending Sample Timestamp in specified time period. | ||||
| CchassisPowerTrendingSampleAve | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Chassis Power Trending Sample Average Power in specified time period. | ||||
| NchassisThermalTrending | 1.3.6.1.4.1.2.3.51.2.2.10.5.5 | |||
| SchassisThermalTrendingPeriod | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Specify time period of thermal trending information. NOTE: This time period should be configured before displaying the following Thermal Trending Information table for Chassis.
| ||||
| Tmt1ThermalTrendingTable | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10 | NA | mandatory | |
table · not-accessible · mandatory Table of Media Tray 1 Thermal Trending Information. | ||||
| Rmt1ThermalTrendingEntry | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1 | NA | mandatory | |
| Cmt1ThermalTrendingIndex | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Media Tray 1 Thermal Trending Table Index. | ||||
| Cmt1ThermalTrendingTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Media Tray 1 Thermal Trending Table Sample Timestamp. | ||||
| Cmt1ThermalTrendingTemperature | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Media Tray 1 Thermal Trending Table Temperature. | ||||
| Tmt2ThermalTrendingTable | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.15 | NA | mandatory | |
table · not-accessible · mandatory Table of Media Tray 2 Thermal Trending Information. NOTE: This MIB object is for BladeCenter HT only. | ||||
| Rmt2ThermalTrendingEntry | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1 | NA | mandatory | |
row · not-accessible · mandatory Media Tray 2 Thermal Trending entry. NOTE: This MIB object is for BladeCenter HT only. | ||||
| Cmt2ThermalTrendingIndex | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Media Tray 2 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter HT only. | ||||
| Cmt2ThermalTrendingTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Media Tray 2 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter HT only. | ||||
| Cmt2ThermalTrendingTemperature | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Media Tray 2 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter HT only. | ||||
| Tblower1ThermalTrendingTable | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.20 | NA | mandatory | |
table · not-accessible · mandatory Table of Blower 1 Thermal Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Rblower1ThermalTrendingEntry | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1 | NA | mandatory | |
| Cblower1ThermalTrendingIndex | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blower 1 Thermal Trending Table Index. | ||||
| Cblower1ThermalTrendingTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower 1 Thermal Trending Table Sample Timestamp. | ||||
| Cblower1ThermalTrendingTemperature | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower 1 Thermal Trending Table Temperature. | ||||
| Tblower2ThermalTrendingTable | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.30 | NA | mandatory | |
table · not-accessible · mandatory Table of Blower 2 Thermal Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Rblower2ThermalTrendingEntry | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1 | NA | mandatory | |
| Cblower2ThermalTrendingIndex | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blower 2 Thermal Trending Table Index. | ||||
| Cblower2ThermalTrendingTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower 2 Thermal Trending Table Sample Timestamp. | ||||
| Cblower2ThermalTrendingTemperature | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower 2 Thermal Trending Table Temperature. | ||||
| Tblower3ThermalTrendingTable | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.40 | NA | mandatory | |
table · not-accessible · mandatory Table of Blower 3 Thermal Trending Information. NOTE: This MIB object is for BladeCenter T only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Rblower3ThermalTrendingEntry | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1 | NA | mandatory | |
row · not-accessible · mandatory Blower 3 Thermal Trending entry. NOTE: This MIB object is for BladeCenter T only. | ||||
| Cblower3ThermalTrendingIndex | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blower 3 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter T only. | ||||
| Cblower3ThermalTrendingTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower 3 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter T only. | ||||
| Cblower3ThermalTrendingTemperature | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower 3 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter T only. | ||||
| Tblower4ThermalTrendingTable | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.50 | NA | mandatory | |
table · not-accessible · mandatory Table of Blower 4 Thermal Trending Information. NOTE: This MIB object is for BladeCenter T only. | ||||
| Rblower4ThermalTrendingEntry | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1 | NA | mandatory | |
row · not-accessible · mandatory Blower 4 Thermal Trending entry. NOTE: This MIB object is for BladeCenter T only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| Cblower4ThermalTrendingIndex | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blower 4 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter T only. | ||||
| Cblower4ThermalTrendingTimeStamp | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower 4 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter T only. | ||||
| Cblower4ThermalTrendingTemperature | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower 4 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter T only. | ||||
| NpowerPolicyInformation | 1.3.6.1.4.1.2.3.51.2.2.10.6 | |||
| TpowerPolicyTable | 1.3.6.1.4.1.2.3.51.2.2.10.6.1 | NA | mandatory | |
table · not-accessible · mandatory Table of Power Policy information for all power domains. Reading this table can tell you about the available power policies that can be configured for a domain and also which is currently selected. The powerPolicyActivate object can also be SET to select which policy should be active for a given power domain. | ||||
| RpowerPolicyEntry | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1 | NA | mandatory | |
| CpowerPolicyIndex | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The unique idenitifier of a row in the powerPolicyTable. | ||||
| CpowerPolicyPowerDomainNumber | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The power domain number which this row is associated with.
| ||||
| CpowerPolicyName | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The short name of the power policy. The following are the possible
names and their detailed description:
Power Module Redundancy
Intended for a single AC power source into the chassis
where each Power Module is on its own dedicated circuit.
Total allowed power draw is limited to one less than the
number of Power Modules when more than one Power Module is
present. One Power Module can fail without affecting blade
operation. Multiple Power Module failures can cause
the chassis to power off. Note that some blades may not be
allowed to power on if doing so would exceed the policy power
limit.
Power Module Redundancy with Blade Throttling Allowed
Very similar to the Power Module Redundancy policy. This
policy allows you to draw more total power; however, capable
blades may be allowed to throttle down if one Power Module fails.
Basic Power Management
Total allowed power is higher than other policies and is limited only
by the total power capacity of all the Power Modules up to the maximum
of chassis power rating. This is the least conservative approach, since
it does not provide any protection for AC power source or Power Module
failure. If any single power supply fails, blade and/or chassis
operation may be affected.
AC Power Source Redundancy
Intended for dual AC power sources into the chassis. Total
allowed power draw is limited to the capacity of two Power
Modules. This is the most conservative approach and is
recommended when all four Power Modules are installed.
When the chassis is correctly wired with dual AC power
sources, one AC power source can fail without affecting
blade operation. Note that some blades may not be
allowed to power on if doing so would exceed the policy
power limit.
AC Power Source Redundancy with Blade Throttling Allowed
Very similar to the AC Power Source Redundancy policy. This policy
allows you to draw more total power; however, capable blades
may be allowed to throttle down if one AC power source fails. | ||||
| CpowerPolicyPwrSupplyFailureLimit | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The maximum number of power supplies that can fail in a chassis while still providing redundancy. | ||||
| CpowerPolicyMaxPowerLimit | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The maximum power available (in watts), based on the number of power modules and the Power Management Policy setting. | ||||
| CpowerPolicyEstimatedUtilization | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.6 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The estimated utilization (as a percentage) based on current power usage. | ||||
| CpowerPolicyActivate | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory When read, this object provides the status of this power policy. If the value is enabled(1), it means this is the active power policy for the associated domain. When set to a value of enabled(1), the power policy will be made the active one for the associated domain. A set of disabled(0) is not allowed. The SET may fail when the user goes from a less restrictive policy to a more restrictive policy, e.g. no power management to redundant power modules. This happens because the AMM might have allocated more power for components in the less restrictive policy. Then if a user wants to go to a more restrictive policy, the power available may be lower than what was already allocated. The SET should always succeed if a user goes from a more restrictive to a less restrictive policy.
| ||||
| Nfrontbezel | 1.3.6.1.4.1.2.3.51.2.2.12 | |||
| SfrontbezelExists | 1.3.6.1.4.1.2.3.51.2.2.12.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether the front bezel is installed or not. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| Nusers | 1.3.6.1.4.1.2.3.51.2.2.17 | |||
| NmmUsers | 1.3.6.1.4.1.2.3.51.2.2.17.1 | |||
| TcurrentlyLoggedInTable | 1.3.6.1.4.1.2.3.51.2.2.17.1.1 | NA | mandatory | |
table · not-accessible · mandatory Table of MM users currently logged in. NOTE: This MIB object is for AMM only. | ||||
| RcurrentlyLoggedInEntry | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1 | NA | mandatory | |
row · not-accessible · mandatory MM users currently logged in entries. NOTE: This MIB object is for AMM only. | ||||
| CcurrentlyLoggedInEntryIndex | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.1 | INTEGER (0..255) | RO | mandatory |
column · INTEGER (0..255) · read-only · mandatory Index for MM users currently logged in. | ||||
| CcurrentlyLoggedInEntryUserId | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.2 | OCTET STRING (SIZE (0..64)) | RO | mandatory |
column · OCTET STRING (SIZE (0..64)) · read-only · mandatory Name for MM users currently logged in. NOTE: 'Default SNMPv1 user' indicates an internal user used by SNMPv1 agent. | ||||
| CcurrentlyLoggedInEntryAccMethod | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.3 | OCTET STRING (SIZE (0..32)) | RO | mandatory |
column · OCTET STRING (SIZE (0..32)) · read-only · mandatory Access method for MM users currently logged in. | ||||
| NmonitorThresholds | 1.3.6.1.4.1.2.3.51.2.2.20 | |||
| NvoltageThresholds | 1.3.6.1.4.1.2.3.51.2.2.20.2 | |||
| TvoltageThresholdsTable | 1.3.6.1.4.1.2.3.51.2.2.20.2.1 | NA | mandatory | |
table · not-accessible · mandatory Table of voltage threshold entries. NOTE: This MIB object is for BladeCenter only. | ||||
| RvoltageThresholdsEntry | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1 | NA | mandatory | |
row · not-accessible · mandatory Voltage threshold entries. NOTE: This MIB object is for BladeCenter only. | ||||
| CvoltageThresholdEntryIndex | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.1 | INTEGER (0..255) | RO | mandatory |
column · INTEGER (0..255) · read-only · mandatory Index for voltage threshold entry. | ||||
| CvoltageThresholdEntryName | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.2 | OCTET STRING (SIZE (0..16)) | RO | mandatory |
column · OCTET STRING (SIZE (0..16)) · read-only · mandatory Voltage threshold entry null terminated string that contains the power supply's name, for example '+5V'. | ||||
| CvoltageThresholdEntryCurrentValue | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system. | ||||
| CvoltageThresholdEntryWarningHighValue | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage threshold reading expressed in Volts(V).
If the voltage rises above this value, a warning
alert/event, if enabled, will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system. | ||||
| CvoltageThresholdEntryWarningResetHighValue | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage threshold reading expressed in Volts(V).
If the voltage rises above this value and
if a warning alert/event had previously been
created, then the alert/event will be reset.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system. | ||||
| CvoltageThresholdEntryWarningLowValue | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage threshold reading expressed in Volts(V).
If the voltage drops below this value, a warning
alert/event, if enabled, will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system. | ||||
| CvoltageThresholdEntryWarningResetLowValue | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage threshold reading expressed in Volts(V).
If the voltage drops below this value and
if a warning alert/event had previously been
created, then the alert/event will be reset.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system. | ||||
| NvpdInformation | 1.3.6.1.4.1.2.3.51.2.2.21 | |||
| NchassisVpd | 1.3.6.1.4.1.2.3.51.2.2.21.1 | |||
| NbladeCenterVpd | 1.3.6.1.4.1.2.3.51.2.2.21.1.1 | |||
| SbladeCenterVpdMachineType | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.1 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Machine type VPD information (from System BIOS). This field must be four alpha numeric characters. | ||||
| SbladeCenterVpdMachineModel | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.2 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Machine model VPD information (from System BIOS). This field must be three alpha numeric characters. | ||||
| SbladeCenterSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.3 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Machine serial number VPD information (from System BIOS). This field must be seven alpha numeric characters. | ||||
| SbladeCenterUUID | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.4 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Machine UUID (Universal Unique ID information) (from System BIOS). This field must be 32 alpha numeric characters. | ||||
| SbladeCenterManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.5 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Machine chassis manufacturing ID. | ||||
| SbladeCenterHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.6 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Machine chassis hardware revision. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| SbladeCenterFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.7 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Machine chassis FRU number. | ||||
| SbladeCenterManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.8 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Machine chassis manufacture date. | ||||
| SbladeCenterPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.9 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Machine chassis part number. | ||||
| SbladeCenterFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.10 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Machine chassis FRU serial number. | ||||
| SbladeCenterManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.11 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Machine chassis manufacturer ID Number. | ||||
| SbladeCenterProductId | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.12 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Machine chassis product ID. | ||||
| SbladeCenterSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.13 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Machine chassis subsystem manufacturer. | ||||
| SbladeCenterClei | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.14 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Machine chassis Common Language Equipment Identification (CLEI). | ||||
| SbladeCenterDirectSerialAttach | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.15 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Presence of the Direct Serial Attach Module. NOTE: This MIB object is for BCS only.
| ||||
| SbladeCenterHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.16 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Machine chassis hardware revision in string format. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| NmmHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.2 | |||
| TmmHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.2.1 | NA | mandatory | |
table · not-accessible · mandatory Table of the management module hardware components. For consistent results, view as a table and not as individual entries. | ||||
| RmmHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1 | NA | mandatory | |
row · not-accessible · mandatory Management module hardware VPD entry. For consistent results, view as a table and not as individual entries.
| ||||
| CmmHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Management module hardware VPD index. For consistent results, view as a table and not as individual entries. | ||||
| CmmHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | ||||
| CmmHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| CmmHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | ||||
| CmmHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Management module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CmmHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module hardware VPD UUID. For consistent results, view as a table and not as individual entries. | ||||
| CmmHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries. | ||||
| CmmHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module hardware VPD Part number. For consistent results, view as a table and not as individual entries. | ||||
| CmmHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. | ||||
| CmmHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. | ||||
| CmmHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module hardware VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| CmmHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries. | ||||
| CmmHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CmmHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| TmmInpHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.2.2 | NA | mandatory | |
table · not-accessible · mandatory Table of the management module interposer hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| RmmInpHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1 | NA | mandatory | |
row · not-accessible · mandatory Management module Interposer hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmmInpHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Management module Interposer hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmmInpHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module Interposer hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmmInpHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module Interposer hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmmInpHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module Interposer hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmmInpHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Management module Interposer hardware VPD hardware revision.
For consistent results, view as a table and not as individual entries.
NOTE: This MIB object is for BladeCenter HT only.
If a hardware revision is programmed in the OEM VPD area for this component,
then the HardwareRevisionString version of this MIB object should be used. | ||||
| CmmInpHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module Interposer hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmmInpHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module Interposer hardware VPD manufacture date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmmInpHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module Interposer hardware VPD Part number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmmInpHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module Interposer hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmmInpHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module Interposer hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. | ||||
| CmmInpHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module Interposer hardware VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| CmmInpHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module Interposer hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries. | ||||
| CmmInpHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module Interposer hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CmmInpHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module Interposer hardware VPD hardware revision in string format.
For consistent results, view as a table and not as individual entries.
NOTE: This MIB object is for BladeCenter HT only.
If a hardware revision is programmed in the OEM VPD area for this component,
then this version of this MIB object should be used. | ||||
| NmmFirmwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.3 | |||
| TmmMainApplVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.3.1 | NA | mandatory | |
table · not-accessible · mandatory Table of MM Firmware VPD. | ||||
| RmmMainApplVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1 | NA | mandatory | |
| CmmMainApplVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Firmware VPD index. | ||||
| CmmMainApplVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Firmware VPD name description. 'AMM firmware' indicates the running firmware of the MM. 'AMM firmware (pending restart)' indicates the flashed firmware of the MM which will become active after the next restart. | ||||
| CmmMainApplVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Firmware VPD build identification. | ||||
| CmmMainApplVpdRevisonNumber | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Firmware VPD revision number. | ||||
| CmmMainApplVpdFilename | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Firmware VPD file name. | ||||
| CmmMainApplVpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Firmware VPD build date. | ||||
| TmmBootROMVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.3.2 | NA | deprecated | |
table · not-accessible · deprecated Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported. | ||||
| RmmBootROMVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1 | NA | deprecated | |
row · not-accessible · deprecated MM Firmware VPD entry. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported.
| ||||
| CmmBootROMVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.1 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Firmware VPD index. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmBootROMVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.2 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD name description. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmBootROMVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.3 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD build identification. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmBootROMVpdRevisonNumber | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.4 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD revision number. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmBootROMVpdFilename | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.5 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD file name. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmBootROMVpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.6 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD build date. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | ||||
| TmmRemoteControlVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.3.3 | NA | deprecated | |
table · not-accessible · deprecated Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported. | ||||
| RmmRemoteControlVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1 | NA | deprecated | |
row · not-accessible · deprecated MM Firmware VPD entry. NOTE: This table is deprecated and no longer supported. | ||||
| CmmRemoteControlVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.1 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Firmware VPD index. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmRemoteControlVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.2 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD name description. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmRemoteControlVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.3 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmRemoteControlVpdRevisonNumber | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.4 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmRemoteControlVpdFilename | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.5 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD file name. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmRemoteControlVpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.6 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD build date. NOTE: This Mib object is deprecated and no longer supported. | ||||
| TmmPS2toUSBConvVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.3.4 | NA | deprecated | |
table · not-accessible · deprecated Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported. | ||||
| RmmPS2toUSBConvVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1 | NA | deprecated | |
row · not-accessible · deprecated MM Firmware VPD entry. NOTE: This table is deprecated and no longer supported. | ||||
| CmmPS2toUSBConvVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.1 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Firmware VPD index. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmPS2toUSBConvVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.2 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD name description. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmPS2toUSBConvVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.3 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmPS2toUSBConvVpdRevisonNumber | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.4 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmPS2toUSBConvVpdFilename | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.5 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD file name. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmPS2toUSBConvVpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.6 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD build date. NOTE: This Mib object is deprecated and no longer supported. | ||||
| TmmToUSBIntfVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.3.5 | NA | deprecated | |
table · not-accessible · deprecated Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported. | ||||
| RmmToUSBIntfVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1 | NA | deprecated | |
row · not-accessible · deprecated MM Firmware VPD entry. NOTE: This table is deprecated and no longer supported.
| ||||
| CmmToUSBIntfVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.1 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Firmware VPD index. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmToUSBIntfVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.2 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD name description. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmToUSBIntfVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.3 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmToUSBIntfVpdRevisonNumber | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.4 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmToUSBIntfVpdFilename | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.5 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD file name. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CmmToUSBIntfVpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.6 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Firmware VPD build date. NOTE: This Mib object is deprecated and no longer supported. | ||||
| NbladeHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.4 | |||
| TbladeHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.4.1 | NA | mandatory | |
table · not-accessible · mandatory Table of VPD information for the blade hardware components. For consistent results, view as a table and not as individual entries. | ||||
| RbladeHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1 | NA | mandatory | |
row · not-accessible · mandatory Blade hardware VPD entry. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade hardware VPD index. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CbladeHardwareVpdSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD serial number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdMachineType | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD machine type. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD UUID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD Part number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdMachineModel | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD machine model. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CbladeHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.17 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| CbladeDaughterVpdCardType | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.20 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade expansion card (daughter card) VPD type. For consistent results, view as a table and not as individual entries.
| ||||
| CbladeDaughterVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.21 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.22 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) VPD FRU number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.23 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade expansion card (daughter card) VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CbladeDaughterVpdSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.24 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) VPD Serial number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterVpdMachineType | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.25 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) VPD Machine type. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.26 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) VPD UUID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.27 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) VPD Manufacture date. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.28 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) VPD Part number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.29 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) VPD FRU Serial. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.30 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.31 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.32 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) VPD subsystem manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.33 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.34 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| TbladeMACAddressVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.4.2 | NA | mandatory | |
table · not-accessible · mandatory Table of MAC addresses of the blade and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries. | ||||
| RbladeMACAddressVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1 | NA | mandatory | |
row · not-accessible · mandatory Blade MAC address entry. For consistent results, view as a table and not as individual entries. | ||||
| CbladeMACAddressVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade index. For consistent results, view as a table and not as individual entries. | ||||
| CbladeMACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade MAC address 1. For consistent results, view as a table and not as individual entries. | ||||
| CbladeMACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade MAC address 2. For consistent results, view as a table and not as individual entries. | ||||
| CbladeMACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade MAC address 3. For consistent results, view as a table and not as individual entries. | ||||
| CbladeMACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade MAC address 4. For consistent results, view as a table and not as individual entries. | ||||
| CbladeMACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade MAC address 5. For consistent results, view as a table and not as individual entries. | ||||
| CbladeMACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade MAC address 6. For consistent results, view as a table and not as individual entries. | ||||
| CbladeMACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade MAC address 7. For consistent results, view as a table and not as individual entries. | ||||
| CbladeMACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade MAC address 8. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard1MACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard1MACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard1MACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard1MACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard1MACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard1MACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard1MACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard1MACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.17 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard2MACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.18 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 2 MAC address 1. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard2MACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.19 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 2 MAC address 2. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard2MACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.20 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 2 MAC address 3. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard2MACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.21 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 2 MAC address 4. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard2MACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.22 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 2 MAC address 5. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard2MACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.23 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 2 MAC address 6. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard2MACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.24 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 2 MAC address 7. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard2MACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.25 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 2 MAC address 8. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard3MACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.26 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 3 MAC address 1. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard3MACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.27 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 3 MAC address 2. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard3MACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.28 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 3 MAC address 3. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard3MACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.29 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 3 MAC address 4. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard3MACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.30 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 3 MAC address 5. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard3MACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.31 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 3 MAC address 6. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard3MACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.32 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 3 MAC address 7. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard3MACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.33 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 3 MAC address 8. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard4MACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.34 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 4 MAC address 1. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard4MACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.35 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 4 MAC address 2. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard4MACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.36 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 4 MAC address 3. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard4MACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.37 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 4 MAC address 4. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard4MACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.38 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 4 MAC address 5. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard4MACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.39 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 4 MAC address 6. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard4MACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.40 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 4 MAC address 7. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard4MACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.41 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 4 MAC address 8. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard5MACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.42 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 5 MAC address 1. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard5MACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.43 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 5 MAC address 2. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard5MACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.44 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 5 MAC address 3. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard5MACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.45 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 5 MAC address 4. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard5MACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.46 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 5 MAC address 5. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard5MACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.47 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 5 MAC address 6. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard5MACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.48 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 5 MAC address 7. For consistent results, view as a table and not as individual entries. | ||||
| CbladeDaughterCard5MACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.49 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card (daughter card) 5 MAC address 8. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.100 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.101 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.102 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.103 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.104 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.105 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.106 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.107 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress9Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.108 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 9. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress10Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.109 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 10. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress11Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.110 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 11. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress12Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.111 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 12. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress13Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.112 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 13. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress14Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.113 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 14. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress15Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.114 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 15. For consistent results, view as a table and not as individual entries. | ||||
| CbladeHSDaughterCard1MACAddress16Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.115 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade high speed expansion card (daughter card) 1 MAC address 16. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardMACAddress1Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.164 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card MAC address 1. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardMACAddress2Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.165 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card MAC address 2. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardMACAddress3Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.166 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card MAC address 3. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardMACAddress4Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.167 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card MAC address 4. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardMACAddress5Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.168 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card MAC address 5. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardMACAddress6Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.169 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card MAC address 6. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardMACAddress7Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.170 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card MAC address 7. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardMACAddress8Vpd | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.171 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card MAC address 8. For consistent results, view as a table and not as individual entries. | ||||
| TbladeExpBoardVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.4.3 | NA | mandatory | |
table · not-accessible · mandatory Table of VPD information for the blade expansion board components. For consistent results, view as a table and not as individual entries. | ||||
| RbladeExpBoardVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1 | NA | mandatory | |
row · not-accessible · mandatory Blade expansion board VPD entry. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade expansion board VPD index. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD Bay number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD FRU number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade expansion board VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CbladeExpBoardVpdSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD serial number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdMachineType | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD machine type. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD UUID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD Part number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD FRU serial number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdMachineModel | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD machine model. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD Product ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdBladeBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.19 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade bay number of the blade expansion board. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpBoardVpdCardType | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.20 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade expansion board VPD type. For consistent results, view as a table and not as individual entries.
| ||||
| CbladeExpBoardVpdCardSubType | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.21 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade expansion board VPD subtype. Describes the expansion board type with more granularity. bse1,bse2,bse3 = Blade Storage Expansion (1st, 2nd, and 3rd Generations), peu1 = PCI Expansion (1st Generation), peu2 = PCI Expansion Unit II, peu3 = bpe3 = PCI Express Expansion Unit, bie= Blade I/O Expansion For consistent results, view as a table and not as individual entries.
| ||||
| CbladeExpBoardVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.22 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion board VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| TbladeSideCardVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.4.4 | NA | mandatory | |
table · not-accessible · mandatory Table of VPD information for the blade side card components. For consistent results, view as a table and not as individual entries. | ||||
| RbladeSideCardVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1 | NA | mandatory | |
row · not-accessible · mandatory Blade side card VPD entry. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade side card VPD index. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD Bay number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD FRU number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade side card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CbladeSideCardVpdSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD serial number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdMachineType | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD machine type. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD UUID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD Part number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD FRU serial number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdMachineModel | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD machine model. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD Product ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdBladeBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.19 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade bay number of the blade side card. For consistent results, view as a table and not as individual entries. | ||||
| CbladeSideCardVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.20 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade side card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| TbladeExpCardVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.4.5 | NA | mandatory | |
table · not-accessible · mandatory Table of VPD information for the blade expansion card components. For consistent results, view as a table and not as individual entries. | ||||
| RbladeExpCardVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1 | NA | mandatory | |
row · not-accessible · mandatory Blade expansion card VPD entry. For consistent results, view as a table and not as individual entries.
| ||||
| CbladeExpCardVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade expansion card VPD index. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD Bay number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD FRU number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade expansion card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CbladeExpCardVpdSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD serial number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdMachineType | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD machine type. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD UUID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD Part number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD FRU serial number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdMachineModel | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD machine model. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD Product ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdBladeBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.19 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade bay number of the blade expansion card. For consistent results, view as a table and not as individual entries. | ||||
| CbladeExpCardVpdCardTypeInfo | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.21 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade expansion card (daughter card) VPD type code that describes the expansion card. For consistent results, view as a table and not as individual entries. NOTE: The CFFe expansion card is also referred to as a CFFh expansion card.
| ||||
| CbladeExpCardVpdHighSpeed | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.22 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade expansion card (daughter card) VPD high speed that indicates whether the expansion card is high speed or not. For consistent results, view as a table and not as individual entries.
| ||||
| CbladeExpCardVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.23 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade expansion card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| TbladecKVMCardVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.4.6 | NA | mandatory | |
table · not-accessible · mandatory Table of VPD information for the blade concurrent keyboard, video, and mouse (cKVM) card components. For consistent results, view as a table and not as individual entries. | ||||
| RbladecKVMCardVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1 | NA | mandatory | |
row · not-accessible · mandatory Blade concurrent keyboard, video, and mouse (cKVM) card VPD entry. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade concurrent keyboard mouse video (cKVM) card VPD index. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD Bay number. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD FRU number. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CbladecKVMCardVpdSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD serial number. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdMachineType | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD machine type. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD UUID. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD Part number. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD FRU serial number. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdMachineModel | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD machine model. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD Product ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CbladecKVMCardVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.17 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade concurrent keyboard video mouse (cKVM) card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| TbladeAndExpCardWwnGuidVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.4.7 | NA | mandatory | |
table · not-accessible · mandatory Table of World Wide Names (WWN), Global Unique IDs (GUID) and Serial Attach SCSI IDs (SAS) of the blade server and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries. | ||||
| RbladeAndExpCardWwnGuidVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1 | NA | mandatory | |
row · not-accessible · mandatory Blade WWN/GUID entries. For consistent results, view as a table and not as individual entries. | ||||
| CbladeAndExpCardWwnGuidVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade or expansion card index. For consistent results, view as a table and not as individual entries. | ||||
| CbladeAndExpCardWwnGuidVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade or expansion card VPD bay number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeAndExpCardWwnGuidVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade or expansion card. For consistent results, view as a table and not as individual entries. | ||||
| CbladeAndExpCardWwnGuidVpdBladeBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory For expansion cards, it's the blade bay number of the blade expansion card. For blades, it's the bay number of the blade. For consistent results, view as a table and not as individual entries. | ||||
| CbladeAndExpCardWwnGuidVpdType | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade or expansion card WWN/GUID/SAS Type. For consistent results, view as a table and not as individual entries.
| ||||
| CbladeAndExpCardWwnGuidVpd1 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade or expansion card WWN/GUID 1. For consistent results, view as a table and not as individual entries. | ||||
| CbladeAndExpCardWwnGuidVpd2 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade or expansion card WWN/GUID 2. For consistent results, view as a table and not as individual entries. | ||||
| CbladeAndExpCardWwnGuidVpd3 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade or expansion card WWN/GUID 3. For consistent results, view as a table and not as individual entries. | ||||
| CbladeAndExpCardWwnGuidVpd4 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade or expansion card WWN/GUID 4. For consistent results, view as a table and not as individual entries. | ||||
| CbladeAndExpCardWwnGuidVpd5 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade or expansion card WWN/GUID 5. For consistent results, view as a table and not as individual entries. | ||||
| CbladeAndExpCardWwnGuidVpd6 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade or expansion card WWN/GUID 6. For consistent results, view as a table and not as individual entries. | ||||
| CbladeAndExpCardWwnGuidVpd7 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade or expansion card WWN/GUID 7. For consistent results, view as a table and not as individual entries. | ||||
| CbladeAndExpCardWwnGuidVpd8 | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade or expansion card WWN/GUID 8. For consistent results, view as a table and not as individual entries. | ||||
| TbladeManagementCardVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.4.8 | NA | mandatory | |
table · not-accessible · mandatory Table of VPD information for the blade management card component. For consistent results, view as a table and not as individual entries. | ||||
| RbladeManagementCardVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1 | NA | mandatory | |
row · not-accessible · mandatory Blade management card VPD entry. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade management card VPD index. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD Bay number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD FRU number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade management card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CbladeManagementCardVpdSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD serial number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdMachineType | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD machine type. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD UUID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD Part number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD FRU serial number. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdMachineModel | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD machine model. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD Product ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CbladeManagementCardVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.17 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blade management card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| NbladeFirmwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.5 | |||
| TbladeBiosVPDTable | 1.3.6.1.4.1.2.3.51.2.2.21.5.1 | NA | mandatory | |
table · not-accessible · mandatory Table of blade firmware vital product data (VPD) information. | ||||
| RbladeBiosVPDEntry | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1 | NA | mandatory | |
| CbladeBiosVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade firmware VPD table index. | ||||
| CbladeBiosVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CbladeBiosVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CbladeBiosVpdPowerState | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified.
| ||||
| CbladeBiosVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CbladeBiosVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The build ID for the blade firmware. | ||||
| CbladeBiosVpdRevision | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The revision of the blade firmware. | ||||
| CbladeBiosVpdDate | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The date of the blade firmware. | ||||
| CbladeBiosVpdLevelStatus | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The level status of the blade bios firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). | ||||
| TbladeDiagsVPDTable | 1.3.6.1.4.1.2.3.51.2.2.21.5.2 | NA | mandatory | |
table · not-accessible · mandatory Table of blade firmware vital product data (VPD) information. | ||||
| RbladeDiagsVPDEntry | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1 | NA | mandatory | |
| CbladeDiagsVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade firmware VPD table index. | ||||
| CbladeDiagsVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CbladeDiagsVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CbladeDiagsVpdPowerState | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified.
| ||||
| CbladeDiagsVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CbladeDiagsVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The build ID for the blade firmware. | ||||
| CbladeDiagsVpdRevision | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The revision of the blade firmware. | ||||
| CbladeDiagsVpdDate | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The date of the blade firmware. | ||||
| CbladeDiagsVpdLevelStatus | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The level status of the blade diagnostics firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). | ||||
| TbladeSysMgmtProcVPDTable | 1.3.6.1.4.1.2.3.51.2.2.21.5.3 | NA | mandatory | |
table · not-accessible · mandatory Table of blade firmware vital product data (VPD) information. | ||||
| RbladeSysMgmtProcVPDEntry | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1 | NA | mandatory | |
| CbladeSysMgmtProcVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade firmware VPD table index. | ||||
| CbladeSysMgmtProcVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CbladeSysMgmtProcVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CbladeSysMgmtProcVpdPowerState | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified.
| ||||
| CbladeSysMgmtProcVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CbladeSysMgmtProcVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The build ID for the blade firmware. | ||||
| CbladeSysMgmtProcVpdRevision | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The revision of the blade firmware. | ||||
| CbladeSysMgmtProcVpdLevelStatus | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The level status of the blade system management processor firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). | ||||
| TbladecKVMVPDTable | 1.3.6.1.4.1.2.3.51.2.2.21.5.4 | NA | mandatory | |
table · not-accessible · mandatory Table of blade firmware vital product data (VPD) information. | ||||
| RbladecKVMVPDEntry | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1 | NA | mandatory | |
| CbladecKVMVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade firmware VPD table index. | ||||
| CbladecKVMVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CbladecKVMVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blade specified exists or not.
| ||||
| CbladecKVMVpdPowerState | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified.
| ||||
| CbladecKVMVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CbladecKVMVpdRevision | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The revision of the blade firmware. | ||||
| NbladeFWBuildIDs | 1.3.6.1.4.1.2.3.51.2.2.21.5.5 | |||
| TbladeFWBuildIDTable | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1 | NA | mandatory | |
table · not-accessible · mandatory Table of Blade Firmware Build ID entries information. | ||||
| RbladeFWBuildIDEntry | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1 | NA | mandatory | |
| CbladeFWBuildIDIndex | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The index number of one Build ID entry. For consistent results, view as a table and not as individual entries. | ||||
| CbladeFWBuildMfg | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.2 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory The Manufacturer property of one Build ID entry. For consistent results, view as a table and not as individual entries. | ||||
| CbladeFWBuildMT | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.3 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory The Machine Type property of one Build ID entry. For consistent results, view as a table and not as individual entries. | ||||
| CbladeFWBuildFWType | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.4 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory The Firmware Type property of one Build ID entry. For consistent results, view as a table and not as individual entries. | ||||
| CbladeFWBuildID | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory The Build ID property of one Build ID entry. For consistent results, view as a table and not as individual entries. | ||||
| CbladeFWBuildRev | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.6 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory The Build Revision property of one Build ID entry. For consistent results, view as a table and not as individual entries. | ||||
| ScreateBladeFWBuildIDs | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.2 | INTEGER | WO | mandatory |
scalar · INTEGER · write-only · mandatory Create one new Build ID List from current installed blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NaddBladeFWBuildID | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3 | |||
| SaddBladeMfg | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.1 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Add one Build ID entry into the Build ID List. This is to set Manufacturer property. | ||||
| SaddBladeMt | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.2 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Add one Build ID entry into the Build ID List. This is to set Machine Type property. | ||||
| SaddBladeFt | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.3 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Add one Build ID entry into the Build ID List. This is to set Firmware Type property. | ||||
| SaddBladeBuildID | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.4 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Add one Build ID entry into the Build ID List. This is to set Build ID property. | ||||
| SaddBladeBuildRev | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.5 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Add one Build ID entry into the Build ID List. This is to set Build Revision property. | ||||
| SexeBladeAdding | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.6 | INTEGER | WO | mandatory |
scalar · INTEGER · write-only · mandatory Add one Build ID entry into the Build ID List. This is to perform the adding action. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SrmBladeFWBuildID | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.4 | INTEGER | WO | mandatory |
scalar · INTEGER · write-only · mandatory Remove one Build ID entry from the Build ID List. The index of the Build ID entry in the list is required. NOTE: Value returned for the GET command is meaningless for this MIB object. | ||||
| SrmAllBladeFWBuildIDs | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.5 | INTEGER | WO | mandatory |
scalar · INTEGER · write-only · mandatory Remove all Build ID entries from the Build ID List. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SbuildIDFileName | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.6 | OCTET STRING (SIZE (0..254)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..254)) · read-write · mandatory File name of the Build ID list that will be used in import function. | ||||
| SbuildIDURIName | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.7 | OCTET STRING (SIZE (0..254)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..254)) · read-write · mandatory Contains the fully qualified remote location of the build ID list. Use buildIDFileName to specify the filename. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the build ID list resides, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The AMM currently supports the following protocols: TFTP, FTP, FTPS, HTTP and HTTPS. The complete format of a fully qualified remote location is: <protocol>://<userid:password>@<hostname:port>/<pathname> An example of a fully qualified remote location can be: ftp://USERID:[email protected]:30045/tmp where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the build ID list is /tmp. Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be: <protocol>://<hostname>/<pathname>. | ||||
| SbuildIDtftpIP | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.8 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..63)) · read-write · mandatory If importing/exporting via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2). | ||||
| SimportBladeFWBuildIDs | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.9 | INTEGER | WO | mandatory |
scalar · INTEGER · write-only · mandatory Import one Build ID List set by the buildIDFilename from a specific location set by buildIDServer.
| ||||
| SexportBladeFWBuildIDs | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.10 | INTEGER | WO | mandatory |
scalar · INTEGER · write-only · mandatory Export the current Build ID List from the active AMM to a specific location set by buildIDServer. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SstatusBladeFWBuildIDs | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.11 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Gives the status message from the last import or export operation. | ||||
| NsmHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.6 | |||
| TsmHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.6.1 | NA | mandatory | |
table · not-accessible · mandatory Table of the switch module hardware components. For consistent results, view as a table and not as individual entries. | ||||
| RsmHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module hardware VPD entry. For consistent results, view as a table and not as individual entries.
| ||||
| CsmHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module hardware VPD index. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CsmHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD UUID. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdWwnGuid | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdWwnGuidType | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.17 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdWidth | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.18 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The width of the switch module hardware. For consistent results, view as a table and not as individual entries. | ||||
| CsmHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.20 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| TsmInpHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.6.2 | NA | mandatory | |
table · not-accessible · mandatory Table of the switch interposer hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| RsmInpHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Interposer hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Interposer hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Interposer hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Interposer hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Interposer hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Interposer hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CsmInpHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Interposer hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Interposer hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Interposer hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Interposer module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Interposer module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Interposer module hardware VPD product ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Interposer module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Interposer module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdWwnGuid | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Interposer module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdWwnGuidType | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.17 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The Switch Interposer WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdWidth | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.18 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The width of the switch Interposer module hardware. For consistent results, view as a table and not as individual entries. | ||||
| CsmInpHardwareVpdName | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.19 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The Switch Interposer Name. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | ||||
| CsmInpHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.20 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Interposer hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| NsmFirmwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.7 | |||
| TsmMainAppVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.7.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module main application VPD information table. | ||||
| RsmMainAppVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module main application VPD table entry
| ||||
| CsmMainAppVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module main application VPD entry index. | ||||
| CsmMainAppVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module numeric identifier.
| ||||
| CsmMainAppVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module specified exists or not.
| ||||
| CsmMainAppVpdSwitchType | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the type of switch module installed.
| ||||
| CsmMainApp1VpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module firmware build id. | ||||
| CsmMainApp1VpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module firmware build date. | ||||
| CsmMainApp1VpdRevisionNumber | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module firmware revision number. | ||||
| CsmMainApp2VpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module firmware build id. | ||||
| CsmMainApp2VpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module firmware build date. | ||||
| CsmMainApp2VpdRevisionNumber | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module firmware revision number. | ||||
| CsmMainApp3VpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory I/O Module firmware build id. | ||||
| CsmMainApp3VpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory I/O Module firmware build date. | ||||
| CsmMainApp3VpdRevisionNumber | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory I/O Module firmware revision number. | ||||
| CsmMainAppVpdSwitchSubType | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.20 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the subtype of switch module installed.
| ||||
| TsmBootRomVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.7.2 | NA | mandatory | |
table · not-accessible · mandatory Switch module boot ROM VPD information table. | ||||
| RsmBootRomVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1 | NA | mandatory | |
| CsmBootRomVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module boot ROM VPD entry index. | ||||
| CsmBootRomVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module numeric identifier.
| ||||
| CsmBootRomVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module specified exists or not.
| ||||
| CsmBootRomVpdSwitchType | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the type of switch module installed.
| ||||
| CsmBootRomVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module firmware build ID. | ||||
| CsmBootRomVpdBuildDate | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module firmware build date. | ||||
| CsmBootRomVpdRevisionNumber | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module firmware revision number. | ||||
| CsmBootRomVpdSwitchSubType | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.8 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the subtype of switch module installed.
| ||||
| NpmHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.8 | |||
| TpmHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.8.1 | NA | mandatory | |
table · not-accessible · mandatory Table of the power module hardware components. For consistent results, view as a table and not as individual entries. | ||||
| RpmHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1 | NA | mandatory | |
row · not-accessible · mandatory Power module hardware VPD entry. For consistent results, view as a table and not as individual entries.
| ||||
| CpmHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power module hardware VPD index. For consistent results, view as a table and not as individual entries. | ||||
| CpmHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | ||||
| CpmHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| CpmHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | ||||
| CpmHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Power module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CpmHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power module hardware VPD UUID. For consistent results, view as a table and not as individual entries. | ||||
| CpmHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power module hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | ||||
| CpmHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. | ||||
| CpmHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. | ||||
| CpmHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CpmHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power module hardware VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| CpmHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CpmHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CpmHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Power module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| NmtHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.9 | |||
| SmtHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.9.3 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 1 hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| SmtHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.9.4 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 1 hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | ||||
| SmtHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.9.5 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Media tray 1 hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| SmtHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.9.8 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 1 hardware VPD UUID. For consistent results, view as a table and not as individual entries. | ||||
| SmtHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.9.9 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 1 hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| SmtHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.9.10 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 1 hardware VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| SmtHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.9.11 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 1 hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| SmtHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.9.12 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 1 hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| SmtHardwareVpdCF1Capacity | 1.3.6.1.4.1.2.3.51.2.2.21.9.13 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 1 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries. | ||||
| SmtHardwareVpdCF2Capacity | 1.3.6.1.4.1.2.3.51.2.2.21.9.14 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 1 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries. | ||||
| SmtHardwareVpdBBU1 | 1.3.6.1.4.1.2.3.51.2.2.21.9.15 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates the presence of Battery Backup Unit 1. NOTE: This MIB object is for BCS only.
| ||||
| SmtHardwareVpdBBU2 | 1.3.6.1.4.1.2.3.51.2.2.21.9.16 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates the presence of Battery Backup Unit 2. NOTE: This MIB object is for BCS only.
| ||||
| SmtHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.9.17 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 1 hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| SmtHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.9.18 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 1 hardware VPD Manufacture Date. | ||||
| SmtHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.9.19 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 1 hardware VPD Part Number. | ||||
| SmtHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.9.20 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 1 hardware VPD FRU Serial. | ||||
| Nmt2HardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.10 | |||
| Smt2HardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.10.3 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 2 hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| Smt2HardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.10.4 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 2 hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | ||||
| Smt2HardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.10.5 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Media tray 2 hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| Smt2HardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.10.8 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 2 hardware VPD UUID. For consistent results, view as a table and not as individual entries. | ||||
| Smt2HardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.10.9 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 2 hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| Smt2HardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.10.10 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 2 hardware VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| Smt2HardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.10.11 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 2 hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| Smt2HardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.10.12 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 2 hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| Smt2HardwareVpdCF1Capacity | 1.3.6.1.4.1.2.3.51.2.2.21.10.13 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 2 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries. | ||||
| Smt2HardwareVpdCF2Capacity | 1.3.6.1.4.1.2.3.51.2.2.21.10.14 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 2 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries. | ||||
| Smt2HardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.10.17 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 2 hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| Smt2HardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.10.18 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 2 hardware VPD Manufacture Date. | ||||
| Smt2HardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.10.19 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 2 hardware VPD Part Number. | ||||
| Smt2HardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.10.20 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Media tray 2 hardware VPD FRU Serial. | ||||
| NblowerFirmwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.12 | |||
| TblowerControllerVPDTable | 1.3.6.1.4.1.2.3.51.2.2.21.12.1 | NA | mandatory | |
table · not-accessible · mandatory Table of blower controller firmware vital product data (VPD) information. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| RblowerControllerVPDEntry | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1 | NA | mandatory | |
row · not-accessible · mandatory Blower controller firmware VPD table entry | ||||
| CblowerControllerVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blower controller firmware VPD table index. | ||||
| CblowerControllerVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blower ID.
| ||||
| CblowerControllerVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blower specified exists or not.
| ||||
| CblowerControllerVpdRevision | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The revision of the blower controller firmware. | ||||
| NblowerHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.13 | |||
| TblowerHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.13.1 | NA | mandatory | |
table · not-accessible · mandatory Table of the blower hardware components. For consistent results, view as a table and not as individual entries. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| RblowerHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1 | NA | mandatory | |
row · not-accessible · mandatory Blower hardware VPD entry. For consistent results, view as a table and not as individual entries. | ||||
| CblowerHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blower hardware VPD index. For consistent results, view as a table and not as individual entries. | ||||
| CblowerHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | ||||
| CblowerHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| CblowerHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | ||||
| CblowerHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blower hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CblowerHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower hardware VPD UUID. For consistent results, view as a table and not as individual entries. | ||||
| CblowerHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. | ||||
| CblowerHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower hardware VPD Part Number. For consistent results, view as a table and not as individual entries. | ||||
| CblowerHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. | ||||
| CblowerHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CblowerHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower hardware VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| CblowerHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CblowerHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CblowerHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Blower hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| NfanPackFirmwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.14 | |||
| TfanPackControllerVPDTable | 1.3.6.1.4.1.2.3.51.2.2.21.14.1 | NA | mandatory | |
table · not-accessible · mandatory Table of fan pack controller firmware vital product data (VPD) information. NOTE: Fan packs are also referred to as Power Module Chassis Cooling Devices. | ||||
| RfanPackControllerVPDEntry | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1 | NA | mandatory | |
row · not-accessible · mandatory Fan Pack controller firmware VPD table entry | ||||
| CfanPackControllerVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Fan Pack controller firmware VPD table index. | ||||
| CfanPackControllerVpdId | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric fan pack ID.
| ||||
| CfanPackControllerVpdExists | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the fan pack specified exists or not.
| ||||
| CfanPackControllerVpdRevision | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The revision of the fan pack controller firmware. | ||||
| NtapHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.15 | |||
| StapHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.15.3 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Telco Alarm Panel hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| StapHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.15.4 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Telco Alarm Panel hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| StapHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.15.5 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Telco Alarm Panel hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| StapHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.15.8 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Telco Alarm Panel hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| StapHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.15.9 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Telco Alarm Panel hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| StapHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.15.10 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Telco Alarm Panel hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| StapHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.15.11 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Telco Alarm Panel hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| StapHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.15.12 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Telco Alarm Panel hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| StapHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.15.13 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Telco Alarm Panel hardware VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| StapHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.15.14 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Telco Alarm Panel hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| StapHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.15.15 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Telco Alarm Panel hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| StapHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.15.16 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Telco Alarm Panel hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| NncHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.16 | |||
| TncHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.16.1 | NA | deprecated | |
table · not-accessible · deprecated Table of the Network Clock hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| RncHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1 | NA | deprecated | |
row · not-accessible · deprecated Network Clock hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CncHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.1 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Network Clock hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CncHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.2 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Network Clock hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CncHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.3 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Network Clock hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CncHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.4 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Network Clock hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CncHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.5 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Network Clock hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CncHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.8 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Network Clock hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CncHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.9 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Network Clock hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CncHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.10 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Network Clock hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CncHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.11 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Network Clock hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CncHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.12 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Network Clock hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CncHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.13 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Network Clock hardware VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| CncHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.14 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Network Clock hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CncHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.15 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Network Clock hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CncHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.16 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated Network Clock hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| NmxHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.17 | |||
| TmxHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.17.1 | NA | mandatory | |
table · not-accessible · mandatory Table of the Multiplexer Expansion Module hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| RmxHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1 | NA | mandatory | |
row · not-accessible · mandatory Multiplexer Expansion Module hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CmxHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Multiplexer Expansion Module hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmxHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Multiplexer Expansion Module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmxHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Multiplexer Expansion Module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmxHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Multiplexer Expansion Module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmxHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Multiplexer Expansion Module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CmxHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Multiplexer Expansion Module hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmxHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Multiplexer Expansion Module hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmxHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Multiplexer Expansion Module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmxHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Multiplexer Expansion Module hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CmxHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Multiplexer Expansion Module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CmxHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Multiplexer Expansion Module hardware VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| CmxHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Multiplexer Expansion Module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CmxHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Multiplexer Expansion Module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CmxHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Multiplexer Expansion Module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| NstmHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.18 | |||
| TstmHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.18.1 | NA | mandatory | |
table · not-accessible · mandatory Table of the Storage Module hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| RstmHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1 | NA | mandatory | |
row · not-accessible · mandatory Storage Module hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
| ||||
| CstmHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Storage Module hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CstmHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CstmHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CstmHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CstmHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Storage Module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | ||||
| CstmHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CstmHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CstmHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CstmHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CstmHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CstmHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module hardware VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| CstmHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CstmHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| CstmHardwareVpdHardwareRevisionString | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | ||||
| NstmFirmwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.19 | |||
| TstmFirmwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.19.1 | NA | mandatory | |
table · not-accessible · mandatory Table of the Storage Module firmware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| RstmFirmwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.19.1.1 | NA | mandatory | |
row · not-accessible · mandatory Storage Module firmware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
| ||||
| CstmFirmwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Storage Module firmware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CstmFirmwareVpdType | 1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module firmware VPD type. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CstmFirmwareVpdBuildId | 1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module firmware VPD build ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CstmFirmwareVpdReleaseDate | 1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module firmware VPD release date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CstmFirmwareVpdRevision | 1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Storage Module firmware VPD revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| NbbuHardwareVpd | 1.3.6.1.4.1.2.3.51.2.2.21.21 | |||
| TbbuHardwareVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.21.1 | NA | mandatory | |
table · not-accessible · mandatory Table of the Battery Backup Unit hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| RbbuHardwareVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1 | NA | mandatory | |
row · not-accessible · mandatory Battery Backup Unit hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
| ||||
| CbbuHardwareVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Battery Backup Unit hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CbbuHardwareVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Battery Backup Unit hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CbbuHardwareVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Battery Backup Unit hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CbbuHardwareVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Battery Backup Unit hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CbbuHardwareVpdHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Battery Backup Unit hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CbbuHardwareVpdUuid | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Battery Backup Unit hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CbbuHardwareVpdManufDate | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Battery Backup Unit hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CbbuHardwareVpdPartNumber | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Battery Backup Unit hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CbbuHardwareVpdFruSerial | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Battery Backup Unit hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| CbbuHardwareVpdManufacturingIDNumber | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Battery Backup Unit hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CbbuHardwareVpdProductId | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Battery Backup Unit hardware VPD product ID. For consistent results, view as a table and not as individual entries. | ||||
| CbbuHardwareVpdSubManufacturerId | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Battery Backup Unit hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | ||||
| CbbuHardwareVpdClei | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Battery Backup Unit hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | ||||
| TinventoryManagementActivityVpdTable | 1.3.6.1.4.1.2.3.51.2.2.21.22 | NA | mandatory | |
table · not-accessible · mandatory Table of system component hardware VPD activity log. For consistent results, view as a table and not as individual entries. | ||||
| RinventoryManagementActivityVpdEntry | 1.3.6.1.4.1.2.3.51.2.2.21.22.1 | NA | mandatory | |
row · not-accessible · mandatory System component hardware VPD activity log entry. For consistent results, view as a table and not as individual entries. | ||||
| CcomponentLevelActivityVpdIndex | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory System component level VPD activity log index. For consistent results, view as a table and not as individual entries. | ||||
| CcomponentLevelActivityVpdFruNumber | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory System component level VPD activity log FRU number. For consistent results, view as a table and not as individual entries. | ||||
| CcomponentLevelActivityVpdSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory System component level VPD activity log serial number. For consistent results, view as a table and not as individual entries. | ||||
| CcomponentLevelActivityVpdManufacturingId | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory System component level VPD activity log manufacturing ID. For consistent results, view as a table and not as individual entries. | ||||
| CcomponentLevelActivityVpdBayNumber | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory System component level VPD activity log Bay number. For consistent results, view as a table and not as individual entries. | ||||
| CcomponentLevelActivityVpdAction | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory System component level VPD activity log action (added/removed). For consistent results, view as a table and not as individual entries. | ||||
| CcomponentLevelActivityVpdTimestamp | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory System component level VPD activity log timestamp. For consistent results, view as a table and not as individual entries. | ||||
| CcomponentLevelActivityVpdModuleName | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The module name which this row is associated with. For consistent results, view as a table and not as individual entries. | ||||
| NreloadVpdData | 1.3.6.1.4.1.2.3.51.2.2.21.23 | |||
| SreloadAllVpdData | 1.3.6.1.4.1.2.3.51.2.2.21.23.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reload all VPD data (firmware, hardware, MAC address, WWN/GUID and other Unique ID). NOTE: The value returned for the GET command is meaningless.
| ||||
| SreloadFwVpdData | 1.3.6.1.4.1.2.3.51.2.2.21.23.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reload firmware VPD data. NOTE: The value returned for the GET command is meaningless.
| ||||
| SreloadHwVpdData | 1.3.6.1.4.1.2.3.51.2.2.21.23.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reload hardware VPD data. NOTE: The value returned for the GET command is meaningless.
| ||||
| SreloadMACAddress | 1.3.6.1.4.1.2.3.51.2.2.21.23.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reload blade MAC addresses. NOTE: The value returned for the GET command is meaningless.
| ||||
| SreloadWwnGuidVpdData | 1.3.6.1.4.1.2.3.51.2.2.21.23.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reload blade and I/O module WWN/GUID and other VPD data. NOTE: The value returned for the GET command is meaningless.
| ||||
| NairFilter | 1.3.6.1.4.1.2.3.51.2.2.22 | |||
| NpassiveAirFilter | 1.3.6.1.4.1.2.3.51.2.2.22.1 | |||
| SpassiveAirFilterStatus | 1.3.6.1.4.1.2.3.51.2.2.22.1.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable/Reset the passive air filter. When enabled, sending an enable or reset will reset the replace date.
The reset command is only applicable in BladeCenter Telco Refresh and it will restart the Fouled Filter Detection settings.
NOTE: This MIB object is only applicable for BladeCenter S, BladeCenter E Refresh, and BladeCenter Telco Refresh.
| ||||
| SpassiveAirFilterMonthFreq | 1.3.6.1.4.1.2.3.51.2.2.22.1.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The chassis environment. 1 month indicates high dust, 3 months indicates moderate dust and, 6 months indicates low dust. NOTE: This MIB object is for BladeCenter S and BladeCenter E Refresh only.
| ||||
| SpassiveAirFilterReplaceDate | 1.3.6.1.4.1.2.3.51.2.2.22.1.3 | OCTET STRING (SIZE (0..30)) | RO | mandatory |
scalar · OCTET STRING (SIZE (0..30)) · read-only · mandatory The scheduled replacement date of the air filter. NOTE: This MIB object is for BladeCenter S and BladeCenter E Refresh only. | ||||
| NcomponentInformation | 1.3.6.1.4.1.2.3.51.2.2.23 | |||
| NcomponentInventory | 1.3.6.1.4.1.2.3.51.2.2.23.1 | |||
| TcomponentInventoryTable | 1.3.6.1.4.1.2.3.51.2.2.23.1.1 | NA | mandatory | |
table · not-accessible · mandatory Table of component inventory information. Not all components will provide every object defined in the ComponentInventoryEntry. | ||||
| RcomponentInventoryEntry | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1 | NA | mandatory | |
| CcomponentInventoryTopologyPath | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.1 | OCTET STRING (SIZE (0..100)) | RO | mandatory |
column · OCTET STRING (SIZE (0..100)) · read-only · mandatory The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component inventory table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card | ||||
| CcomponentInventoryInstance | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentInventoryTopologyPath object, but this componentInventoryInstance object is provided as a convenience to the user. | ||||
| CcomponentInventoryDescription | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A short text string describing the particular component. For the AMM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object. | ||||
| CcomponentInventoryMachineTypeModel | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The machine type and model number of this component. Typically, the format is XXXXYYY, where XXXX reprsents the machine type and YYY represents the model number. | ||||
| CcomponentInventoryMachineSerial | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The machine serial number of this component. | ||||
| CcomponentInventoryAssetID | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The asset identifier of this component, typically set by some other authority than the manufacturer. | ||||
| CcomponentInventoryPartNumber | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The part number of this component. | ||||
| CcomponentInventoryFRUNumber | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The Field Replaceable Unit (FRU) number of this component. | ||||
| CcomponentInventoryFRUSerialNumber | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The Field Replaceable Unit (FRU) serial number of this component. | ||||
| CcomponentInventoryManufactureID | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The text description of the manufacturer of this component. | ||||
| CcomponentInventoryHardwareRevision | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The hardware revision number of the this component. | ||||
| CcomponentInventoryManufactureDate | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The date when the manufacturer created this component. The format is XXYY, where XX is the week number of the year 20YY. | ||||
| CcomponentInventoryUUID | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The Universally Unique IDentifier (UUID) of this component, represented as a 16 byte hex number. | ||||
| CcomponentInventoryProductID | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The product identifier of the component assigned by the manufacturer. | ||||
| CcomponentInventorySubManufactureID | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The text sub-description of the manufacturer of this component, often used to identify a supplier for a component which has multiple suppliers. | ||||
| CcomponentInventoryCLEI | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The Common Language Equipment Identifier (CLEI) of this component. | ||||
| CcomponentInventoryAssetTag | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.17 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The asset tag of this component. | ||||
| CcomponentInventorySpeed | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.18 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A speed designation for the component, for example, processor speed. | ||||
| CcomponentInventoryIdentifier | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.19 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A unique identifier assigned by the manufacturer to the component, for example, a processor ID. | ||||
| CcomponentInventorySize | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.20 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory A size designation for the component, for example, a memory DIMM size or hard drive capacity. | ||||
| CcomponentInventoryMemoryType | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.21 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The architecture specification of a memory device.
| ||||
| CcomponentInventoryProductName | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.22 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The product name assigned by the manufacturer for this component. For more detail, also refer to the componentInventoryDescription object. | ||||
| CcomponentInventoryProductVersion | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.23 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The product version assigned by the manufacturer for this component. | ||||
| CcomponentInventoryProcessorType | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.24 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The type designation for processor components.
| ||||
| CcomponentInventoryProcessorFamily | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.25 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The family designation for processor components. | ||||
| CcomponentInventoryProcessorCores | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.26 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The number of cores present on a processor component. | ||||
| CcomponentInventoryProcessorThreads | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.27 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The number of threads present on a processor component. | ||||
| CcomponentInventoryProcessorL1DCache | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.28 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The level 1 data cache size of a processor component. | ||||
| CcomponentInventoryProcessorL1ICache | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.29 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The level 1 instruction cache size of a processor component. | ||||
| CcomponentInventoryProcessorL2Cache | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.30 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The level 2 cache size of a processor component. | ||||
| CcomponentInventoryProcessorL3Cache | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.31 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The level 3 cache size of a processor component. | ||||
| CcomponentInventoryProcessorVoltage | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.32 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The voltage rating for a processor component. | ||||
| CcomponentInventoryProcessorExtClock | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.33 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The external clock speed of a processor component. | ||||
| CcomponentInventoryProcessorDataWidth | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.34 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The maximum data bus width capability of a processor component, expressed typically in bits. | ||||
| CcomponentInventoryManufactureIDNum | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.35 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The identification number assigned for the component by the manufacturer. | ||||
| NcomponentFirmware | 1.3.6.1.4.1.2.3.51.2.2.23.2 | |||
| TcomponentFirmwareTable | 1.3.6.1.4.1.2.3.51.2.2.23.2.1 | NA | mandatory | |
table · not-accessible · mandatory Table of component firmware information. Not all components will provide every object defined in the ComponentFirmwareEntry. | ||||
| RcomponentFirmwareEntry | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1 | NA | mandatory | |
row · not-accessible · mandatory Component firmware information. | ||||
| CcomponentFirmwareTopologyPath | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.1 | OCTET STRING (SIZE (0..100)) | RO | mandatory |
column · OCTET STRING (SIZE (0..100)) · read-only · mandatory The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card | ||||
| CcomponentFirmwareIndex | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Each component may have one or more types of firmware associated with it, and this index object identifies the particular instance. | ||||
| CcomponentFirmwareComponentInstance | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentFirmwareTopologyPath object, but this componentFirmwareComponentInstance object is provided as a convenience to the user. | ||||
| CcomponentFirmwareComponentDescription | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A short text string describing the particular component. For the AMM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object. | ||||
| CcomponentFirmwareType | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A text description of the type of firmware load. | ||||
| CcomponentFirmwareBuildID | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A text description of the build identifier for this firmware load. | ||||
| CcomponentFirmwareReleaseDate | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A text description of the release date for this firmware load. | ||||
| CcomponentFirmwareFilename | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A text description of the filename of this firmware load. | ||||
| CcomponentFirmwareRevision | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A text description of the revision level of this firmware load. | ||||
| CcomponentFirmwareRevisionMajor | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory A numeric identifier of the revision major number for this firmware load. | ||||
| CcomponentFirmwareRevisionMinor | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory A numeric identifier of the revision minor number for this firmware load. | ||||
| CcomponentFirmwareLevelStatus | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The level status of the firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). | ||||
| CcomponentFirmwarePendingBuildID | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A text description of the build identifier for this pending firmware load. | ||||
| CcomponentFirmwarePendingReleaseDate | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A text description of the release date for this pending firmware load. | ||||
| CcomponentFirmwarePendingRevision | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A text description of the revision level of this pending firmware load. | ||||
| CcomponentFirmwareTypeID | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.20 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the type of firmware load with a numeric identifier.
| ||||
| ScomponentInventoryReady | 1.3.6.1.4.1.2.3.51.2.2.23.3 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory When a blade management controller or the AMM is reset, the blade inventory data is refreshed in the AMM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the AMM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication when all blades have completed initialization and the inventory information has been provided to the AMM. Note that due to blades that may be experiencing a 'communication failure' or 'initialization failure' condition, this object may continue to show notReady. Therefore, any application that polls this object should also incorporate a timeout period. As of AMM release v5.3, a 10 minute timeout seems to be a minimum suggested polling period. A more granular, per-blade status is available via the bladeSystemStatusTable
| ||||
| TcomponentDriveTable | 1.3.6.1.4.1.2.3.51.2.2.23.10 | NA | mandatory | |
table · not-accessible · mandatory Table of information indicating presence of a disk drive on a component. The management module does not receive any inventory VPD from the component, so only the presence of a drive can be indicated by this table. | ||||
| RcomponentDriveEntry | 1.3.6.1.4.1.2.3.51.2.2.23.10.1 | NA | mandatory | |
| CcomponentDriveTopologyPath | 1.3.6.1.4.1.2.3.51.2.2.23.10.1.1 | OCTET STRING (SIZE (0..100)) | RO | mandatory |
column · OCTET STRING (SIZE (0..100)) · read-only · mandatory The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card | ||||
| CcomponentDriveDescription | 1.3.6.1.4.1.2.3.51.2.2.23.10.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A short text string describing the particular drive on the component. | ||||
| NerrorLogs | 1.3.6.1.4.1.2.3.51.2.3 | |||
| NeventLog | 1.3.6.1.4.1.2.3.51.2.3.4 | |||
| TreadEventLogTable | 1.3.6.1.4.1.2.3.51.2.3.4.2 | NA | mandatory | |
table · not-accessible · mandatory Table of event log entry information. | ||||
| RreadEventLogEntry | 1.3.6.1.4.1.2.3.51.2.3.4.2.1 | NA | mandatory | |
| CreadEventLogIndex | 1.3.6.1.4.1.2.3.51.2.3.4.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The event log index number. For consistent results, view as a table and not as individual entries. | ||||
| CreadEventLogString | 1.3.6.1.4.1.2.3.51.2.3.4.2.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A string of data detailing an event. For consistent results, view as a table and not as individual entries. | ||||
| SclearEventLog | 1.3.6.1.4.1.2.3.51.2.3.4.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Clear the event log. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SmonitorLogStateEvents | 1.3.6.1.4.1.2.3.51.2.3.4.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory If disabled, it means the info LED will not turn on when the log gets full and no alerts will be sent out. If enabled, the LED will turn on when the log gets full and alerts will be sent out.
| ||||
| TreadEnhancedEventLogTable | 1.3.6.1.4.1.2.3.51.2.3.4.6 | NA | mandatory | |
table · not-accessible · mandatory Table of enhanced event log entry information. | ||||
| RreadEnhancedEventLogEntry | 1.3.6.1.4.1.2.3.51.2.3.4.6.1 | NA | mandatory | |
row · not-accessible · mandatory Enhaced Event log table entry, new entries could be added for new items. | ||||
| CreadEnhancedEventLogNumber | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The event log number for the enhanced event log. For consistent results, view as a table and not as individual entries. | ||||
| CreadEnhancedEventLogAttribute | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A string of data detailing an event log's attribute, such as the Event ID and Call Home Flag. The Event ID is a hexadecimal number representing an specific or class of events. The call home flag indicates that the corresponding problem may result in a call home. For consistent results, view as a table and not as individual entries. | ||||
| CreadEnhancedEventLogMessage | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A string of data detailing an event log message. For consistent results, view as a table and not as individual entries. | ||||
| TreadAuditLogTable | 1.3.6.1.4.1.2.3.51.2.3.4.10 | NA | mandatory | |
table · not-accessible · mandatory Table of audit log entry information. Audit log includes the logs whose source is 'Audit' | ||||
| RreadAuditLogEntry | 1.3.6.1.4.1.2.3.51.2.3.4.10.1 | NA | mandatory | |
row · not-accessible · mandatory Audit log table entry, new entries could be added for new items.
| ||||
| CreadAuditLogNumber | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The audit log number. For consistent results, view as a table and not as individual entries. | ||||
| CreadAuditLogAttribute | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A string of data detailing an audit eventlog's attribute. For consistent results, view as a table and not as individual entries. | ||||
| CreadAuditLogMessage | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A string of data detailing an audit event log message. For consistent results, view as a table and not as individual entries. | ||||
| SclearAuditLog | 1.3.6.1.4.1.2.3.51.2.3.4.11 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Clear the audit log. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| TreadSystemLogTable | 1.3.6.1.4.1.2.3.51.2.3.4.12 | NA | mandatory | |
table · not-accessible · mandatory Table of system log entry information. System log includes the logs whose source is other than 'Audit' | ||||
| RreadSystemLogEntry | 1.3.6.1.4.1.2.3.51.2.3.4.12.1 | NA | mandatory | |
row · not-accessible · mandatory System log table entry, new entries could be added for new items.
| ||||
| CreadSystemLogNumber | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The system log index number. For consistent results, view as a table and not as individual entries. | ||||
| CreadSystemLogAttribute | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A string of data detailing an system event log's attribute. For consistent results, view as a table and not as individual entries. | ||||
| CreadSystemLogMessage | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A string of data detailing an system event log message. For consistent results, view as a table and not as individual entries. | ||||
| SclearSystemLog | 1.3.6.1.4.1.2.3.51.2.3.4.13 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Clear the system log. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NconfigureSP | 1.3.6.1.4.1.2.3.51.2.4 | |||
| NremoteAccessConfig | 1.3.6.1.4.1.2.3.51.2.4.1 | |||
| NgeneralRemoteCfg | 1.3.6.1.4.1.2.3.51.2.4.1.1 | |||
| SremoteAlertRetryDelay | 1.3.6.1.4.1.2.3.51.2.4.1.1.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Number in seconds to delay between retries if sending a remote alert is unsuccessful.
| ||||
| SremoteAlertRetryCount | 1.3.6.1.4.1.2.3.51.2.4.1.1.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Number of additional times a remote alert will be retried if not successfully sent. A value of zero indicates no retries will be attempted.
| ||||
| SremoteAlertEntryDelay | 1.3.6.1.4.1.2.3.51.2.4.1.1.5 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Number in seconds to delay between entries if sending a remote alert is unsuccessful. NOTE: This object is no longer supported. However, for compatibilities sake, a value of (255) is returned when read. Also, write access has been removed.
| ||||
| SremoteAccessTamperDelay | 1.3.6.1.4.1.2.3.51.2.4.1.1.6 | INTEGER | RW | deprecated |
scalar · INTEGER · read-write · deprecated This value is no longer supported and has been replaced by 'lockoutPeriod'.
| ||||
| SuserAuthenticationMethod | 1.3.6.1.4.1.2.3.51.2.4.1.1.7 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Use this field to specify how users attempting to login should be authenticated.
There are two methods:
Local authentication. Userid and password are verified by searching the list
of users locally configured under Local Login Profiles.
LDAP based authentication. Users are authenticated via a remote LDAP server.
One or both authentication methods can be selected. If both methods should be
used, the order must be specified.
| ||||
| SmaxSessionsPerLDAPUser | 1.3.6.1.4.1.2.3.51.2.4.1.1.9 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The maximum number of simultaneous active sessions allowed for each LDAP user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20. | ||||
| SauthenticationLoggingTimeout | 1.3.6.1.4.1.2.3.51.2.4.1.1.10 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Use this option to set how long, in seconds, AMM will not log the authentication events for the same user. The default setting is 5 minutes. 0 indicates log all authentication events, 255 indicates don't log any new authentication events.
| ||||
| StrackingIP | 1.3.6.1.4.1.2.3.51.2.4.1.1.11 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory This option indicates tracking different IP addresses for the same user is enabled or not. If it is enabled then an access every second from alternating IP addresses will result in multiple log entries, regardless of the time duration set in the 'authenticaionLoggingTimeout'field. If this flag is disabled, multiple accesses by varying IP addresses will only be logged as 'new' accesses if they are out of the 'authenticationLoggingTimeout'.
| ||||
| NaccountSecurityManagement | 1.3.6.1.4.1.2.3.51.2.4.1.1.20 | |||
| SaccountSecurityLevel | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The level of security needed for local user login passwords.
The legacy level:
- no password required
- no password expiration
- no password re-use restrictions
- no frequency of password change restrictions
- account is locked for 2 minutes after 5 login failures
- simple password rules
- no account inactivity monitoring
The high level:
- password required
- factory default 'USERID' account password must be changed on next login
- force user to change password on first login
- password expires in 90 days
- password re-use checking enabled (last 5 passwords kept in history)
- minimum 24 hours interval between password changes
- account is locked for 60 minutes after 5 login failures
- complex password rules with 2 degrees of difference from previous password
- alert on account inactivity after 120 days
- accounts disabled after 180 days of inactivity
The custom level:
- set the password settings individually under customSecuritySettings
The default value is legacy.
| ||||
| NcustomSecuritySettings | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2 | |||
| SloginPasswordRequired | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory If enabled, all users require a login password to access the AMM. If disabled, empty password is allowed and complex password rules will be disabled automatically. The default value is disabled.
| ||||
| SpasswordExpirationPeriod | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The number of days before login passwords expire. The minimum value is 1 day and the maximum value is 365 days. The default value is 90 days. A value of 0 disables this option. | ||||
| SdefaultAdminPasswordExpired | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory If enabled, the factory default 'USERID' account password must be changed on next login. The default value is disabled.
| ||||
| SminimumPasswordReuseCycle | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The number of unique passwords a user must choose before reusing a password. The default value is none.
| ||||
| ScomplexPasswordRules | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory If enabled, the minimum complexity rules will be enforced for all
local login passwords and 'User login password required' rule will be enabled.
The rules are as follows:
Passwords must be a minimum of eight characters.
Passwords must not be a repeat or reverse of the associated login id.
Passwords must be no more than three of the same characters used consecutively.
Passwords must contain at least three of the following combinations:
At least one lower case alphanumeric character.
At least one upper case alphanumeric character.
At least one numeric character.
At least one special character.
The default value is disabled.
| ||||
| SminimumDiffCharsPassword | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.6 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The required minimum number of characters in the new password different from the previous password. The default value is 2. A SET of this object is ignored until the complexPasswordRules option is enabled and the minimumPasswordReuseCycle is not none(0)
| ||||
| SchangePasswordFirstAccess | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.7 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory If enabled, the login user will be forced to change their password on the first access after the account has been established or on the first access after an administrator has changed the password for the user, except for the administrator password for USERID. The default value is disabled.
| ||||
| SinactivityAlertPeriod | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.8 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The period of time in days before generating an alert for a dormant account. This value applies to all login accounts, including the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be less than the inactivityAlertDisablePeriod. | ||||
| SinactivityAlertDisablePeriod | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.9 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The period of time in days before generating an alert and disabling a dormant account. This value applies to all login accounts, excluding the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be greater than the inactivityAlertPeriod. | ||||
| SlockoutPeriod | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.10 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The period of time in minutes that a user is locked out after the maximum number of login failures was reached. The minimum value is is 1 minute and the maximum value is 2880 minutes. The default value is 2 minutes for the Legacy security level and 60 minutes for the High security level. A value of 0 disables this option. | ||||
| SmaxLoginFailures | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.11 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The maximum number of login failures before a user account is locked. A value of 0 disables this option. The default value is 5.
| ||||
| SpasswordChangeInterval | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.12 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory A minimum period of time that user is not able to change their own password. The range of acceptable values will be from 0 to 1440 (or 60 days). A value of 0 disables this option. If the password expiration period is set, it must be greater than the minimum password change interval. | ||||
| NserialPortCfg | 1.3.6.1.4.1.2.3.51.2.4.1.2 | |||
| SportBaud | 1.3.6.1.4.1.2.3.51.2.4.1.2.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Baud rate for the serial port.
| ||||
| SportParity | 1.3.6.1.4.1.2.3.51.2.4.1.2.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Parity setting for the serial port.
| ||||
| SportStopBits | 1.3.6.1.4.1.2.3.51.2.4.1.2.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Number of stop bits for the serial port.
| ||||
| NremoteAlertIds | 1.3.6.1.4.1.2.3.51.2.4.1.3 | |||
| TremoteAlertIdsTable | 1.3.6.1.4.1.2.3.51.2.4.1.3.1 | NA | mandatory | |
table · not-accessible · mandatory Table of remote alert entries. This table lets you configure remote alert recipients. You can define up to 12 unique recipients. NOTE: All selected alert events will be sent to all enabled alert recipients. | ||||
| RremoteAlertIdsEntry | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1 | NA | mandatory | |
| CremoteAlertIdEntryIndex | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Index for remote alert entry. | ||||
| CremoteAlertIdEntryStatus | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.2 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Remote alert entry status, invalid means entry not defined yet, disabledAndValid means entry defined but not enabled to send an alert, enabledAndValid means entry defined and enabled to send an alert.
| ||||
| CremoteAlertIdEntryIpOrHostAddress | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.3 | OCTET STRING (SIZE (0..50)) | RW | mandatory |
column · OCTET STRING (SIZE (0..50)) · read-write · mandatory A null terminated string that either contains an IP address of the form '1.2.3.4' or a host name (if DNS is enabled) for the alert entry. | ||||
| CremoteAlertIdEntryTextDescription | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.4 | OCTET STRING (SIZE (0..50)) | RW | mandatory |
column · OCTET STRING (SIZE (0..50)) · read-write · mandatory A null terminated string that contains a text description of this entry. | ||||
| CremoteAlertIdEntryNotificationType | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.5 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Remote alert entry notification method. Types include unknown when the type can't be determined (read-only), ibmDirectorOverLAN for a LAN alert sent over ethernet to IBM director, snmpOverLan for an SNMP alert over ethernet, and emailOverLan for a E-Mail alert over ethernet.
| ||||
| CremoteAlertIdEmailAddr | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.9 | OCTET STRING (SIZE (0..64)) | RW | mandatory |
column · OCTET STRING (SIZE (0..64)) · read-write · mandatory A null terminated string that contains an E-Mail Address. For example, '[email protected]'. Used only for an E-mail over LAN or E-Mail over PPP notification type. | ||||
| CremoteAlertIdEntrySelectiveAlert | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.13 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Remote alert entry selective alert setting. A value of critOnlyAlerts will only send critical alerts to this remote alert recipient, a value of allAlerts will send all alerts to this remote alert recipient.
| ||||
| SgenerateTestAlert | 1.3.6.1.4.1.2.3.51.2.4.1.3.30 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate a Test Alert. This will send a test alert to all configured and enabled remote alert recipients. The text portion of the alert will contain 'Application Posted Alert to MM'. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NremoteAccessIds | 1.3.6.1.4.1.2.3.51.2.4.1.4 | |||
| TremoteAccessIdsTable | 1.3.6.1.4.1.2.3.51.2.4.1.4.1 | NA | mandatory | |
table · not-accessible · mandatory Table of remote access profiles. This table lets you to configure all login profiles. You can define up to 12 unique profiles. NOTE: By default, the management module comes configured with one login profile that allows remote access using a login ID of 'USERID' and a password of 'PASSW0RD' (the 0 is a zero). To avoid a potential security exposure, we strongly recommend that you change this default Login Profile to values of your choice. | ||||
| RremoteAccessIdsEntry | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1 | NA | mandatory | |
| CremoteAccessIdEntryIndex | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.1 | INTEGER (0..255) | RO | mandatory |
column · INTEGER (0..255) · read-only · mandatory Index for Remote access entry. | ||||
| CremoteAccessIdEntryUserId | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.2 | OCTET STRING (SIZE (0..15)) | RW | mandatory |
column · OCTET STRING (SIZE (0..15)) · read-write · mandatory Remote access entry null terminated string that contains the user-id. It must not be a duplicate of any previously configured ones. | ||||
| CremoteAccessIdEntryPassword | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.3 | OCTET STRING (SIZE (0..15)) | RW | mandatory |
column · OCTET STRING (SIZE (0..15)) · read-write · mandatory Remote access password. The password must contain at least one alphabetic and one non-alphabetic character and be at least 5 characters long, or you can leave the password field blank to set an empty password. NOTE: Value returned by the GET command is meaningless for this MIB object. | ||||
| CremoteAccessIdEntryEncodedLoginPw | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.7 | OCTET STRING (SIZE (0..36)) | RW | deprecated |
column · OCTET STRING (SIZE (0..36)) · read-write · deprecated Used only for configuration save/restore. A null terminated string containing an encoded concatenation of the login ID and password separated by an ':'. This object is no longer supported and will return a string of asterisks | ||||
| CremoteAccessIdEntryRole | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates if user has supervisor, operator, or custom access. | ||||
| CremoteAccessIdEntryLoggedIn | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if user is currently logged in or not.
| ||||
| CremoteAccessIdEntryLastLogin | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Timestamp for the last successful login by the user. | ||||
| CremoteAccessIdEntryPwdCompliant | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.13 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if user complies with all of the password rules currently in effect.
| ||||
| CremoteAccessIdEntryPwdExp | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The number of days until the user's current password expires. | ||||
| CremoteAccessIdEntryDormant | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if the user account has been inactive for a specified amount of time based on inactivityAlertDisablePeriod in the customSecuritySettings section.
| ||||
| CremoteAccessIdEntryState | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the state of the user:
Active - normal state
Disabled - user cannot use account until enabled by a
supervisor or chassis user account manager. An account
can get disabled after being dormant for a specified
amount of time OR as a result of a supervisor or chassis
user account manager disabling it.
Locked - account is temporarily locked due to repeated
unsuccessful login attempts as specified by lockoutPeriod
in the customSecuritySettings section. Account can be
unlocked by a supervisor or chassis user account manager
OR can be automatically unlocked after the lockoutPeriod expires.
NOTE: The disable action does not apply to supervisor or chassis
user account manager accounts.
| ||||
| CremoteAccessIdEntryAction | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.17 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Actions that only a supervisor or chassis user account manager
can perform for each user id:
Enable - enables an account in the Disabled state
Disable - disables an account in the Active or Locked state
Unlock - unlock an account in the Locked state
NOTE: The disable action does not apply to supervisor or chassis
user account manager accounts.
NOTE: Value returned for the GET command is meaningless for this
MIB object.
| ||||
| CremoteAccessIdEntrySessionCount | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.18 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The number of sessions the user is currently logged in to. | ||||
| CremoteAccessIdEntryMaxSessions | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.19 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The maximum number of simultaneous active sessions allowed for the user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20. | ||||
| TremoteAccessUserAuthorityLevelTable | 1.3.6.1.4.1.2.3.51.2.4.1.4.2 | NA | mandatory | |
table · not-accessible · mandatory Table of user authority level profiles. | ||||
| RremoteAccessUserAuthorityLevelEntry | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1 | NA | mandatory | |
| CualIndex | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.1 | INTEGER (0..255) | RO | mandatory |
column · INTEGER (0..255) · read-only · mandatory Index for User Authority Level entry. | ||||
| CualId | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.2 | OCTET STRING (SIZE (0..16)) | RO | mandatory |
column · OCTET STRING (SIZE (0..16)) · read-only · mandatory User ID | ||||
| CualSupervisor | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has no restrictions.
| ||||
| CualReadOnly | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has only read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.).
| ||||
| CualAccountManagement | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.5 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User can add/modify/delete users and change the global login settings in the Login Profiles panel.
| ||||
| CualConsoleAccess | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User can access the remote console.
| ||||
| CualConsoleAndVirtualMediaAccess | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User can access both the remote console and the virtual media feature.
| ||||
| CualServerPowerAccess | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User can access the power on and restart functions for the remote server. These functions are available via the Power/Restart panel.
| ||||
| CualAllowClearLog | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the logs.
| ||||
| CualAdapterBasicConfig | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.10 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User can modify configuration parameters in the System Settings and Alerts panels.
| ||||
| CualAdapterNetworkAndSecurityConfig | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.11 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User can modify configuration parameters in the Security, Network Protocols, Network Interface, Port Assignments, and Serial Port panels.
| ||||
| CualAdapterAdvancedConfig | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.12 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has no restrictions when configuring the adapter. In addition, the user is said to have administrative access to the RSA, meaning that the user can also perform the following advanced functions: firmware upgrades, PXE network boot, restore adapter factory defaults, modify and restore adapter configuration from a configuration file, and restart/reset the adapter.
| ||||
| TremoteAccessRBSroleTable | 1.3.6.1.4.1.2.3.51.2.4.1.4.3 | NA | mandatory | |
table · not-accessible · mandatory Table of RBS User Role profiles. | ||||
| RremoteAccessRBSroleEntry | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1 | NA | mandatory | |
| CroleIndex | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.1 | INTEGER (0..255) | RO | mandatory |
column · INTEGER (0..255) · read-only · mandatory Index for RBS User Role entry. | ||||
| CroleId | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.2 | OCTET STRING (SIZE (0..16)) | RO | mandatory |
column · OCTET STRING (SIZE (0..16)) · read-only · mandatory User ID | ||||
| CrbsSupervisor | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has no restrictions.
| ||||
| CrbsOperator | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.).
| ||||
| CrbsChassisOperator | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.5 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has ability to browse status and properties of chassis components (MM, blowers (chassis cooling devices), midplane, power modules, media tray. Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access.
| ||||
| CrbsChassisAccountManagement | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority.
| ||||
| CrbsChassisLogManagement | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file.
| ||||
| CrbsChassisConfiguration | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the user also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file.
| ||||
| CrbsChassisAdministration | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the user also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file.
| ||||
| CrbsBladeOperator | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.10 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has ability to browse status and properties of blades.
| ||||
| CrbsBladeRemotePresence | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.11 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. The ability to issue the CLI console command to start an SOL session to a blade will also require this authority.
| ||||
| CrbsBladeConfiguration | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.12 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User can modify and save any blade configuration parameter.
| ||||
| CrbsBladeAdministration | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.13 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs.
| ||||
| CrbsSwitchModuleOperator | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.14 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has ability to browse status and properties of I/O Modules, and to ping I/O Modules.
| ||||
| CrbsSwitchModuleConfiguration | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.15 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module.
| ||||
| CrbsSwitchModuleAdministration | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.16 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module.
| ||||
| CrbsBladeRemotePresenseVideo | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.17 | INTEGER | RW | deprecated |
column · INTEGER · read-write · deprecated User can browser Remote Control web panel and remote blade video. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool.
| ||||
| CrbsBladeRemotePresenseKVM | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.18 | INTEGER | RW | deprecated |
column · INTEGER · read-write · deprecated User has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool.
| ||||
| CrbsBladeRemotePresenseRdriveR | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.19 | INTEGER | RW | deprecated |
column · INTEGER · read-write · deprecated User can mount remote blade driver, and have read access only. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool.
| ||||
| CrbsBladeRemotePresenseRdriveRW | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.20 | INTEGER | RW | deprecated |
column · INTEGER · read-write · deprecated User can mount remote blade driver and have read/write access. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool.
| ||||
| CrbsChassisRemotePresenseRdoc | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.21 | INTEGER | RW | deprecated |
column · INTEGER · read-write · deprecated User has ability to upload/delete own image to RDOC and also can start remote control web panel. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool.
| ||||
| CrbsRemotePresenceSupervisor | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.22 | INTEGER | RW | deprecated |
column · INTEGER · read-write · deprecated User has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote driver read/write, upload/delete himself and other's image to RDOC. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool.
| ||||
| TremoteAccessRBSscopeTable | 1.3.6.1.4.1.2.3.51.2.4.1.4.4 | NA | mandatory | |
table · not-accessible · mandatory Table of RBS User Scope profiles. | ||||
| RremoteAccessRBSscopeEntry | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1 | NA | mandatory | |
| CscopeIndex | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.1 | INTEGER (0..255) | RO | mandatory |
column · INTEGER (0..255) · read-only · mandatory Index for RBS User Scope Entry. | ||||
| CscopeId | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.2 | OCTET STRING (SIZE (0..16)) | RO | mandatory |
column · OCTET STRING (SIZE (0..16)) · read-only · mandatory User ID | ||||
| CrbsChassis | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the MM and chassis functions.
| ||||
| CrbsBlade1 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 1.
| ||||
| CrbsBlade2 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.5 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 2.
| ||||
| CrbsBlade3 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 3.
| ||||
| CrbsBlade4 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 4.
| ||||
| CrbsBlade5 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 5.
| ||||
| CrbsBlade6 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 6.
| ||||
| CrbsBlade7 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.10 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 7.
| ||||
| CrbsBlade8 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.11 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 8.
| ||||
| CrbsBlade9 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.12 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 9.
| ||||
| CrbsBlade10 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.13 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 10.
| ||||
| CrbsBlade11 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.14 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 11.
| ||||
| CrbsBlade12 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.15 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 12.
| ||||
| CrbsBlade13 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.16 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 13.
| ||||
| CrbsBlade14 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.17 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to the blade in slot 14.
| ||||
| CrbsSwitch1 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.18 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to I/O module 1.
| ||||
| CrbsSwitch2 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.19 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to I/O module 2.
| ||||
| CrbsSwitch3 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.20 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to I/O module 3.
| ||||
| CrbsSwitch4 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.21 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to I/O module 4.
| ||||
| CrbsSwitch5 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.22 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to I/O module 5.
| ||||
| CrbsSwitch6 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.23 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to I/O module 6.
| ||||
| CrbsSwitch7 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.24 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to I/O module 7.
| ||||
| CrbsSwitch8 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.25 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to I/O module 8.
| ||||
| CrbsSwitch9 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.26 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to I/O module 9.
| ||||
| CrbsSwitch10 | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.27 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory User has access to I/O module 10.
| ||||
| NuserInterfaces | 1.3.6.1.4.1.2.3.51.2.4.1.5 | |||
| Scli | 1.3.6.1.4.1.2.3.51.2.4.1.5.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Enable/Disable CLI access to the MM (telnet and SSH). The value enabled(3) means both telnet and ssh are enabled.
| ||||
| Ssnmp | 1.3.6.1.4.1.2.3.51.2.4.1.5.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Enable/Disable SNMP v1 and v3 access to the MM.
| ||||
| Stcm | 1.3.6.1.4.1.2.3.51.2.4.1.5.3 | INTEGER (0..20) | RW | mandatory |
scalar · INTEGER (0..20) · read-write · mandatory Enable/Disable TCM access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. | ||||
| Sweb | 1.3.6.1.4.1.2.3.51.2.4.1.5.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Enable/Disable Web access (HTTP/HTTPS) to the MM.
NOTE: Disabling web access to the MM will cause all
currently active web sessions to disconnect,
and you will no longer be able to access the
MM management functions using a web browser.
| ||||
| Sstcm | 1.3.6.1.4.1.2.3.51.2.4.1.5.5 | INTEGER (0..20) | RW | mandatory |
scalar · INTEGER (0..20) · read-write · mandatory Enable/Disable STCM access to the MM.
A value of 0 means disabled, any value from 1 to 20 means enabled.
NOTE: AMM will provide a max of 20 connections for both
Secure TCP Command Mode and TCP Command Mode.
If no valid server certificate is in place,
Secure TCP Command Mode will not be allowed to set to enable. | ||||
| NmmSshClientAuth | 1.3.6.1.4.1.2.3.51.2.4.1.6 | |||
| TmmSshClientAuthPubKeyTable | 1.3.6.1.4.1.2.3.51.2.4.1.6.1 | NA | mandatory | |
table · not-accessible · mandatory A table that contains client authentication public key information. | ||||
| RmmSshClientAuthPubKeyEntry | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1 | NA | mandatory | |
row · not-accessible · mandatory A information list about a particular SSH public key used for client authentication. The primary table index is the same value as the associated remoteAccessIdEntryIndex. The secondary table index allows selection of the Nth public key for that remoteAccessIdEntryIndex. | ||||
| CmmSshClientAuthRemoteAccessIdIndex | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.1 | INTEGER | NA | mandatory |
column · INTEGER · not-accessible · mandatory The primary table index is the same value as the associated remoteAccessIdEntryIndex used as an index into the remoteAccessIdsTable. | ||||
| CmmSshClientAuthPubKeyIndex | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.2 | INTEGER | NA | mandatory |
column · INTEGER · not-accessible · mandatory The secondary table index used to select one of the client authentication public keys for a particular remote access Id. The index is an integer value from 1 to N where N is the number of keys associated with a particular remote access Id. An addition always causes the value of N to increase by one, effectively adding an entry after the existing keys for that remote access Id. If an entry is deleted from the table by setting mmSshClientAuthPubKeyEntryStatus = invalid, the key associated with that entry is deleted. If the deleted key was not the last key for a remote access Id (mmSshClientAuthPubKeyIndex is not the 'last' or Nth entry), the subsequent entries are renumbered after the deletion. A deletion always causes the value of N to decrease by one. The underlying SSH server implementation searches the keys in order from 1 to N when attempting public key authentication. NOTE:A maximum of 4 public keys can be installed for one remote access Id. | ||||
| CmmSshClientAuthPubKeyType | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The type of the SSH public key represented by this entry.
| ||||
| CmmSshClientAuthPubKeySize | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The size of the SSH public key represented by this entry.
| ||||
| CmmSshClientAuthPubKeyFingerprint | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The RSA fingerprint of the SSH public key represented by this entry. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the managed entity. This is the fingerprint of the operational host key pair. If the key pair represented by this entry is not operational then sixteen null octets must be returned. | ||||
| CmmSshClientAuthPubKeyAcceptFrom | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.6 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory This is a filter that describes the set of SSH client
IP addresses and host names that can establish
SSH connections to the AMM authenticated by the public key
represented by this entry of the table. The filter is a
comma-separated list of IP addresses and/or hostnames.
A question mark may be used to match any single character.
An asterisk may be used to match multiple characters.
An exclamation point may preceed an IP address or hostname
to deny acccess from that IP address or hostname.
The format of the Accept From specification is:
from=PATTERN-LIST
PATTERN-LIST is the filter, which must be enclosed in
double quotation marks.
NOTE:This MIB object can be manipulated after the
corresponding SSH public key is installed. | ||||
| CmmSshClientAuthPubKeyComment | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.7 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory This is a descriptive string that the administrator may use to help identify the public key represented by this entry. It serves no function in the operation of the SSH server. NOTE:This MIB object can be manipulated after the corresponding SSH public key is installed. | ||||
| CmmSshClientAuthPubKeyAction | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory import(1) starts the TFTP file transfer of an SSH client authentication public key from the TFTP server to the AMM. The import operation is only accepted if the associated RemoteAccessIdsEntry row is configured and the current value of mmSshClientAuthPubKeyEntryStatus is underCreation(3) or valid(1), if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1), it will replace the key with a new key, If the import is successful the value of mmSshClientAuthPubKeyRowStatus changes to valid(1). export(2) starts the TFTP file transfer of an SSH client authentication public key from the AMM to the TFTP server. The export operation is only accepted if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1). NOTE: Users should compare the fingerprint value mmSshClientAuthPubKeyFingerprint to the fingerprint of client authentication key files imported or exported using the TFTP file transfer protocol to guard against possible file corruption. Value returned for the GET command is meaningless for this MIB object.
| ||||
| CmmSshClientAuthPubKeyEntryStatus | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.9 | EntryStatus | RW | mandatory |
column · EntryStatus · read-write · mandatory This object manages the creation and deletion of this entry.
The steps recommended to install and to activate a new client
authorization public key are:
1. Set values for mmSshClientAuthPubKeyTftpServer,
mmSshClientAuthPubKeyFileName, mmSshClientAuthPubKeyFileFormat
2. Create a new entry in this table
mmSshClientAuthPubKeyEntryStatus = createRequest
3. Import a new key mmSshClientAuthPubKeyAction = import
This entry will be valid after mmSshClientAuthPubKeyAction
is successfully imported.
4. Set mmSshClientAuthPubKeyAcceptFrom and
mmSshClientAuthPubKeyComment as required.
valid(1) - Indicates that the public key pair represented
by this entry is available for use by the Secure
Shell Server for client authentication.
createRequest(2) - A new entry will be created in this table
for the specified host key pair and the new
entry will transition to the underCreation(3)
state. The operation is only accepted if the
associated RemoteAccessIdsEntry row defining
a local user account is configured.
underCreation(3) - Indicates that this entry exists in the
agent but is unavailable for use. After completing the
create operation, the agent will set this object to
underCreation(3).
invalid(4) - Deletes this entry and any client authentication
public key that may be associated with it. | ||||
| SmmSshClientAuthPubKeyUnused | 1.3.6.1.4.1.2.3.51.2.4.1.6.2 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The number of available storage locations that may be used to install additional Client Authentication Public Keys. This number decreases by one when a new key is added to the configuration. | ||||
| SmmSshClientAuthPubKeyTftpServer | 1.3.6.1.4.1.2.3.51.2.4.1.6.3 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory IP address or host name of the TFTP server where an SSH client authentication public key is to be installed from or exported to. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2). | ||||
| SmmSshClientAuthPubKeyFileName | 1.3.6.1.4.1.2.3.51.2.4.1.6.4 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory File name on the TFTP server of an SSH client authentication public key. | ||||
| SmmSshClientAuthPubKeyFileFormat | 1.3.6.1.4.1.2.3.51.2.4.1.6.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory File format of SSH client authentication public key files imported from or exported to the TFTP file server.
| ||||
| NgroupProfiles | 1.3.6.1.4.1.2.3.51.2.4.1.7 | |||
| TgroupIdsTable | 1.3.6.1.4.1.2.3.51.2.4.1.7.1 | NA | mandatory | |
table · not-accessible · mandatory Table of Group profiles. This table lets you to configure all group profiles. You can define up to 16 unique profiles. | ||||
| RgroupIdsEntry | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1 | NA | mandatory | |
| CgroupIndex | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.1 | INTEGER (0..255) | RO | mandatory |
column · INTEGER (0..255) · read-only · mandatory Index for Group IDs entry. | ||||
| CgroupId | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.2 | OCTET STRING (SIZE (0..16)) | RW | mandatory |
column · OCTET STRING (SIZE (0..16)) · read-write · mandatory Group ID. It is a null terminated string that contains the group-id. It must not be a duplicate of any previously configured ones. | ||||
| CgroupRole | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Group Role. It indicates if the group has supervisor, operator, or custom access. | ||||
| CgroupEntryStatus | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.9 | EntryStatus | RW | mandatory |
column · EntryStatus · read-write · mandatory This object manages the creation and deletion of this entry.
The steps recommended to add a new group are:
1. Create a new entry in this table
groupEntryStatus = createRequest
2. Set groupId as required.
Then the entry will be valid.
valid(1) - Indicates that the group represented
by this entry is available for use.
createRequest(2) - A new entry will be created in this table
for the specified group and the new entry
will transition to the underCreation(3).
underCreation(3) - Indicates that this entry exists in the
agent but is unavailable for use. After completing the
create operation, the agent will set this object to
underCreation(3).
invalid(4) - Deletes this entry. | ||||
| TgroupRBSroleTable | 1.3.6.1.4.1.2.3.51.2.4.1.7.2 | NA | mandatory | |
table · not-accessible · mandatory Table of Group Role profiles. | ||||
| RgroupRBSroleEntry | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1 | NA | mandatory | |
| CgroupRBSroleIndex | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.1 | INTEGER (0..255) | RO | mandatory |
column · INTEGER (0..255) · read-only · mandatory Index for Group Role entry. | ||||
| CgroupRBSroleId | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.2 | OCTET STRING (SIZE (0..16)) | RO | mandatory |
column · OCTET STRING (SIZE (0..16)) · read-only · mandatory Group ID | ||||
| CgroupRBSSupervisor | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has no restrictions.
| ||||
| CgroupRBSOperator | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.).
| ||||
| CgroupRBSChassisOperator | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.5 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has ability to browse status and properties of chassis components (MM, blowers (chassis cooling devices), midplane, power modules, media tray. Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access.
| ||||
| CgroupRBSChassisAccountManagement | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority.
| ||||
| CgroupRBSChassisLogManagement | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file.
| ||||
| CgroupRBSChassisConfiguration | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the group also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file.
| ||||
| CgroupRBSChassisAdministration | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the group also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file.
| ||||
| CgroupRBSBladeOperator | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.10 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has ability to browse status and properties of blades.
| ||||
| CgroupRBSBladeRemotePresence | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.11 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. The ability to issue the CLI console command to start an SOL session to a blade will also require this authority.
| ||||
| CgroupRBSBladeConfiguration | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.12 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group can modify and save any blade configuration parameter.
| ||||
| CgroupRBSBladeAdministration | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.13 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs.
| ||||
| CgroupRBSSwitchModuleOperator | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.14 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has ability to browse status and properties of I/O Modules, and to ping I/O Modules.
| ||||
| CgroupRBSSwitchModuleConfiguration | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.15 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module.
| ||||
| CgroupRBSSwitchModuleAdministration | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.16 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module.
| ||||
| TgroupRBSscopeTable | 1.3.6.1.4.1.2.3.51.2.4.1.7.3 | NA | mandatory | |
table · not-accessible · mandatory Table of Group Scope profiles. | ||||
| RgroupRBSscopeEntry | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1 | NA | mandatory | |
| CgroupRBSscopeIndex | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.1 | INTEGER (0..255) | RO | mandatory |
column · INTEGER (0..255) · read-only · mandatory Index for Group Scope Entry. | ||||
| CgroupRBSscopeId | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.2 | OCTET STRING (SIZE (0..16)) | RO | mandatory |
column · OCTET STRING (SIZE (0..16)) · read-only · mandatory Group ID | ||||
| CgroupRBSChassis | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the MM and chassis functions.
| ||||
| CgroupRBSBlade1 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 1.
| ||||
| CgroupRBSBlade2 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.5 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 2.
| ||||
| CgroupRBSBlade3 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 3.
| ||||
| CgroupRBSBlade4 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 4.
| ||||
| CgroupRBSBlade5 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 5.
| ||||
| CgroupRBSBlade6 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 6.
| ||||
| CgroupRBSBlade7 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.10 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 7.
| ||||
| CgroupRBSBlade8 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.11 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 8.
| ||||
| CgroupRBSBlade9 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.12 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 9.
| ||||
| CgroupRBSBlade10 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.13 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 10.
| ||||
| CgroupRBSBlade11 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.14 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 11.
| ||||
| CgroupRBSBlade12 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.15 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 12.
| ||||
| CgroupRBSBlade13 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.16 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 13.
| ||||
| CgroupRBSBlade14 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.17 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to the blade in slot 14.
| ||||
| CgroupRBSSwitch1 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.18 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to I/O module 1.
| ||||
| CgroupRBSSwitch2 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.19 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to I/O module 2.
| ||||
| CgroupRBSSwitch3 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.20 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to I/O module 3.
| ||||
| CgroupRBSSwitch4 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.21 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to I/O module 4.
| ||||
| CgroupRBSSwitch5 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.22 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to I/O module 5.
| ||||
| CgroupRBSSwitch6 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.23 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to I/O module 6.
| ||||
| CgroupRBSSwitch7 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.24 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to I/O module 7.
| ||||
| CgroupRBSSwitch8 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.25 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to I/O module 8.
| ||||
| CgroupRBSSwitch9 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.26 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to I/O module 9.
| ||||
| CgroupRBSSwitch10 | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.27 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Group has access to I/O module 10.
| ||||
| NremoteAlerts | 1.3.6.1.4.1.2.3.51.2.4.2 | |||
| NremoteAlertsCrit | 1.3.6.1.4.1.2.3.51.2.4.2.1 | |||
| ScritTemp | 1.3.6.1.4.1.2.3.51.2.4.2.1.1 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if any of the monitored temperature sensors
in the system exceed their critical threshold.
NOTE: If a critical Temperature condition is detected,
the server will automatically be shut down and powered off
whether this object is enabled or not.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| ScritVolt | 1.3.6.1.4.1.2.3.51.2.4.2.1.2 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate a alert if any of the monitored power supply sensors
in the system fall outside their specified critical
operational range.
NOTE: If a critical voltage condition is detected,
the server will automatically be shut down and powered off
whether this object is enabled or not.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| ScritMultiBlower | 1.3.6.1.4.1.2.3.51.2.4.2.1.4 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if multiple blowers used for cooling the system fail.
NOTE: Blowers are also referred to as Chassis Cooling Devices.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| ScritPower | 1.3.6.1.4.1.2.3.51.2.4.2.1.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert if any of the system power supplies fail.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| ScritHardDrive | 1.3.6.1.4.1.2.3.51.2.4.2.1.6 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if any of hard disk drives fail.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| ScritVRM | 1.3.6.1.4.1.2.3.51.2.4.2.1.7 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if any of VRM (voltage regulator modules) fail.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| ScritMultipleSwitchModule | 1.3.6.1.4.1.2.3.51.2.4.2.1.8 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if all switch modules fail or are removed.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| ScritInvalidConfig | 1.3.6.1.4.1.2.3.51.2.4.2.1.9 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if the hardware configuration is incompatible.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| ScritBlade | 1.3.6.1.4.1.2.3.51.2.4.2.1.10 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any critical error condition on a blade.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| ScritIO | 1.3.6.1.4.1.2.3.51.2.4.2.1.11 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any critical error condition on I/O module.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| ScritStorage | 1.3.6.1.4.1.2.3.51.2.4.2.1.12 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any critical error condition on a Storage module.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
NOTE: This MIB object is for BCS only.
| ||||
| ScritChassis | 1.3.6.1.4.1.2.3.51.2.4.2.1.13 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any critical error condition on chassis.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| ScritFan | 1.3.6.1.4.1.2.3.51.2.4.2.1.14 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any critical error condition on cooling devices.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| NremoteAlertsNonCrit | 1.3.6.1.4.1.2.3.51.2.4.2.2 | |||
| SwarnSingleBlower | 1.3.6.1.4.1.2.3.51.2.4.2.2.2 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if one blower used for cooling the system fails.
NOTE: Blowers are also referred to as Chassis Cooling Devices.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| SwarnTemp | 1.3.6.1.4.1.2.3.51.2.4.2.2.3 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if any of the monitored temperature sensors
in the system exceed their warning threshold.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| SwarnVoltage | 1.3.6.1.4.1.2.3.51.2.4.2.2.4 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if any of the monitored power supply sensors
in the system fall outside their specified warning operational range.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| SwarnRedundantModule | 1.3.6.1.4.1.2.3.51.2.4.2.2.6 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if any of the switch modules or management
modules is failing or removed.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| SwarnMediaTrayKVMSwitch | 1.3.6.1.4.1.2.3.51.2.4.2.2.7 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if the system detects a Media Tray or KVM
switching failure.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| SwarnLogFull | 1.3.6.1.4.1.2.3.51.2.4.2.2.10 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert if the system log reaches 100% full.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SwarnBlade | 1.3.6.1.4.1.2.3.51.2.4.2.2.15 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any warning condition on a blade.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SwarnIO | 1.3.6.1.4.1.2.3.51.2.4.2.2.16 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any warning condition on I/O module.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SwarnStorage | 1.3.6.1.4.1.2.3.51.2.4.2.2.17 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any warning condition on a Storage module.
NOTE: This MIB object is for BCS only.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SwarnPower | 1.3.6.1.4.1.2.3.51.2.4.2.2.18 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any warning condition on power module.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SwarnChassis | 1.3.6.1.4.1.2.3.51.2.4.2.2.19 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any warning condition on chassis.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SwarnFan | 1.3.6.1.4.1.2.3.51.2.4.2.2.20 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any warning condition on cooling devices.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| NremoteAlertsSystem | 1.3.6.1.4.1.2.3.51.2.4.2.3 | |||
| SsystemPowerOff | 1.3.6.1.4.1.2.3.51.2.4.2.3.4 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if the system is powered off.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| SsystemPowerOn | 1.3.6.1.4.1.2.3.51.2.4.2.3.5 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate a alert if the system is powered on.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| SsystemPFA | 1.3.6.1.4.1.2.3.51.2.4.2.3.8 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate a alert if the system hardware detects a Predictive
Failure Analysis(PFA) on PFA enabled hardware.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| SsystemInventory | 1.3.6.1.4.1.2.3.51.2.4.2.3.10 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert if the a processor blade or media tray is
added or removed.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SsystemLog75PctFull | 1.3.6.1.4.1.2.3.51.2.4.2.3.11 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert if the system log reaches 75% full.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SnetworkChangeNotification | 1.3.6.1.4.1.2.3.51.2.4.2.3.12 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert if the SP has restarted and the internal
network has initialized successfully, or if an IP address
change via a source other than the management module.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SsystemBladeThrottling | 1.3.6.1.4.1.2.3.51.2.4.2.3.13 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if any of the server blades are throttling.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| SsystemPowerManagement | 1.3.6.1.4.1.2.3.51.2.4.2.3.14 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Generate an alert if the system detects a power oversubscription
condition or power supply mismatch in a power domain.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts.
| ||||
| SsystemRemoteLogin | 1.3.6.1.4.1.2.3.51.2.4.2.3.15 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert if the system detects a new user logged in from
a remote site.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SsystemBlade | 1.3.6.1.4.1.2.3.51.2.4.2.3.16 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any informational condition on a blade.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SsystemIO | 1.3.6.1.4.1.2.3.51.2.4.2.3.17 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any informational condition on I/O module.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SsystemStorage | 1.3.6.1.4.1.2.3.51.2.4.2.3.18 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any informational condition on a Storage module.
NOTE: This MIB object is for BCS only.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SsystemPower | 1.3.6.1.4.1.2.3.51.2.4.2.3.19 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any informational condition on power module.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SsystemChassis | 1.3.6.1.4.1.2.3.51.2.4.2.3.20 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any informational condition on chassis.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SsystemFan | 1.3.6.1.4.1.2.3.51.2.4.2.3.21 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any informational condition on cooling device.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SsystemPWRDO | 1.3.6.1.4.1.2.3.51.2.4.2.3.22 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate an alert for any informational condition on power on and power off.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all alert
category configuration.
| ||||
| SalertMode | 1.3.6.1.4.1.2.3.51.2.4.2.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Selects which alert categories will be displayed on the
web interface, which alert category objects are accessible
through SNMP, and which SNMP trap type an alert is associated with.
The enhanced option provides a component based category
category scheme and is the only one that is now supported.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They are
now also changed to be read-only and any future modifications
to the alert category settings must be done only with the
enahanced(1) mode alerts. Therefore, this setting should
have a value of enhanced(1).
| ||||
| NsecuritySettings | 1.3.6.1.4.1.2.3.51.2.4.3 | |||
| SdataEncryption | 1.3.6.1.4.1.2.3.51.2.4.3.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory If enabled, all confidential data will be encrypted. The default value is disabled. NOTE: Once the data is encrypted, the only way to reverse this process is to reset to default values.
| ||||
| StrespassWarning | 1.3.6.1.4.1.2.3.51.2.4.3.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory If enabled, a customizable trespass warning message is displayed via the Web and CLI interfaces.
| ||||
| StrespassWarningDefault | 1.3.6.1.4.1.2.3.51.2.4.3.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reset the trespass warning to default value. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| StrespassMessage | 1.3.6.1.4.1.2.3.51.2.4.3.4 | OCTET STRING (SIZE (0..1600)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..1600)) · read-write · mandatory The value of the trespass warning message. | ||||
| NspClock | 1.3.6.1.4.1.2.3.51.2.4.4 | |||
| SspClockDateAndTimeSetting | 1.3.6.1.4.1.2.3.51.2.4.4.1 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory MM clock date and time setting. A date-time specification for the local time of day. For example to set the date and time to March 4, 2001 at 06:00:00AM, set the value to:'03/04/2001,06:00:00'. field contents range _____ ________ _____ 1 month 01..12 2 separator '/' 3 day 01..31 4 separator '/' 5 year 2000..2089 6 separator ',' 7 hour 00..23 8 separator ':' 9 minutes 00..59 10 separator ':' 11 seconds 00..59 | ||||
| SspClockTimezoneSetting | 1.3.6.1.4.1.2.3.51.2.4.4.2 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory MM clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST)
settings.
The following table lists GMT offsets and associated DST
information. DST is not observed in time zones where
the 'Observe DST' value does not contain 'yes' in the table.
Also, note that in some cases additional information
is required to determine the clock adjustment when DST is
observed. The additional information is required when the
GMT offset being written is +2:00 or +10:00.
Examples
-to set the GMT offset to +3:30,
set the value to:'+3:30,no'
-for Eastern Standard Time and observing DST,
set the value to:'-5:00,yes'
-for Egypt and observing DST,
set the value to:'+2:00,yes,6'
GMT Observe Additional
Offset DST? DST value
______ _______ __________
+0:00 yes|no
+1:00 yes|no
+2:00 yes|no When 'Observe DST?' value is 'yes':
5 (for E.Europe)
4 (for GTB)
6 (for Egypt)
7 (for FLE)
+3:00 yes|no
+3:30 yes|no
+4:00 no
+4:30 no
+5:00 yes|no
+5:30 no
+6:00 no
+7:00 no
+8:00 yes|no
+9:00 yes|no
+9:30 yes|no When 'Observe DST?' value is 'yes':
10 (for South AUS)
9 (for other locations)
+10:00 yes|no When 'Observe DST?' value is 'yes':
9 (for AUS Eastern)
10 (for TAS,ACT,NSW,VIC)
4 (for Vladivostok)
+11:00 no
+12:00 yes|no
-12:00 no
-11:00 no
-10:00 no
-9:00 yes|no When 'Observe DST?' value is 'yes':
12 (for USA and Canada)
1 (for other locations)
-8:00 yes|no When 'Observe DST?' value is 'yes':
12 (for USA and Canada)
1 (for other locations)
-7:00 yes|no When 'Observe DST?' value is 'yes':
12 (for USA and Canada)
1 (for other locations)
-6:00 yes|no When 'Observe DST?' value is 'yes':
12 (for USA and Canada)
1 (for other locations)
-5:00 yes|no When 'Observe DST?' value is 'yes':
12 (for USA and Canada)
1 (for other locations)
-4:00 yes|no When 'Observe DST' value is 'yes':
12 (for Canada)
1 (for other locations)
-3:30 yes|no
-3:00 yes|no
-2:00 yes|no
-1:00 yes|no | ||||
| NspIdentification | 1.3.6.1.4.1.2.3.51.2.4.5 | |||
| SspTxtId | 1.3.6.1.4.1.2.3.51.2.4.5.1 | OCTET STRING (SIZE (0..16)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..16)) · read-write · mandatory MM text ID. NOTE: Do not put any 'space characters' at end of the ID. | ||||
| NnetworkConfiguration | 1.3.6.1.4.1.2.3.51.2.4.9 | |||
| NnetworkInterfaces | 1.3.6.1.4.1.2.3.51.2.4.9.1 | |||
| NextEthernetInterface | 1.3.6.1.4.1.2.3.51.2.4.9.1.1 | |||
| SextEthernetInterfaceType | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.1 | OCTET STRING (SIZE (0..16)) | RO | mandatory |
scalar · OCTET STRING (SIZE (0..16)) · read-only · mandatory The type of interface. Indicates 'Ethernet-1'. | ||||
| SextEthernetInterfaceHostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.3 | OCTET STRING (SIZE (0..64)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-write · mandatory Contains the 64 byte null terminated DNS host name for this interface. | ||||
| SextEthernetInterfaceIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.4 | IpAddress | RW | mandatory |
scalar · IpAddress · read-write · mandatory Contains the IP address for the ethernet interface. | ||||
| SextEthernetInterfaceDataRate | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G Auto or Auto. Note that not all AMM hardware supports the 1G Auto speed. If it does not and a SET of this value is attempted, it will be rejected with a badValue return code. When a user selects the 1G Auto setting, the duplex setting will be forced to fullDuplex.
| ||||
| SextEthernetInterfaceDuplexSetting | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.6 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. When a user selects the 1G Auto speed setting, the duplex setting will be forced to fullDuplex.
| ||||
| SextEthernetInterfaceLAA | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.7 | OCTET STRING (SIZE (17)) | RW | mandatory |
scalar · OCTET STRING (SIZE (17)) · read-write · mandatory Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup AMM, it is not recommended. | ||||
| SextEthernetInterfaceDhcpEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.8 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable or enable DHCP on this interface.
| ||||
| SextEthernetInterfaceGatewayIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.9 | IpAddress | RW | mandatory |
scalar · IpAddress · read-write · mandatory Contains the IP address of the gateway/router for the ethernet interface. | ||||
| SextEthernetInterfaceBIA | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.10 | OCTET STRING (SIZE (17)) | RO | mandatory |
scalar · OCTET STRING (SIZE (17)) · read-only · mandatory Specifies the burned-in MAC (BIA) address. | ||||
| SextEthernetInterfaceMTU | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.13 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Contains the Maximum Transmission Unit(MTU) for the ethernet interface | ||||
| SextEthernetInterfaceSubnetMask | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.14 | IpAddress | RW | mandatory |
scalar · IpAddress · read-write · mandatory Contains the subnet mask for the ethernet interface | ||||
| NdhcpEthernetInterface | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16 | |||
| SdhcpHostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.1 | OCTET STRING (SIZE (0..64)) | RO | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. | ||||
| SdhcpIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.2 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the IP address for the ethernet interface, assigned by the DHCP server. | ||||
| SdhcpGatewayIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.3 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. | ||||
| SdhcpSubnetMask | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.4 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server. | ||||
| SdhcpDomainName | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.5 | OCTET STRING (SIZE (0..64)) | RO | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. | ||||
| SdhcpDHCPServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.6 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the DHCP server IP address used to acquire the DHCP settings. | ||||
| SdhcpPrimaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.7 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the Primary DNS server, assigned by the DHCP server. | ||||
| SdhcpSecondaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.8 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the Secondary DNS server, assigned by the DHCP server. | ||||
| SdhcpTertiaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.9 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the tertiary DNS server, assigned by the DHCP server. | ||||
| NintEthernetInterface | 1.3.6.1.4.1.2.3.51.2.4.9.1.2 | |||
| SintEthernetInterfaceType | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.1 | OCTET STRING (SIZE (0..16)) | RO | deprecated |
scalar · OCTET STRING (SIZE (0..16)) · read-only · deprecated The type of interface. Indicates 'PPP-1'. NOTE: This Mib object is deprecated and no longer supported. | ||||
| SintEthernetInterfaceEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.2 | INTEGER | RW | deprecated |
scalar · INTEGER · read-write · deprecated Disable or enable the internal ethernet interface. NOTE: To alter any of the configuration settings for the ethernet interface, the following procedure should be used: (1) This object should be set to 'interfaceDisabled' (2) Make the modifications to other settings (3) This object should be set to 'interfaceEnabled' (4) Restart the management module Also note that when attempting to enable this interface, the remote IP address is verified to be nonzero. If this verification fails, an error response will be returned and the internal ethernet interface will be left disabled. NOTE: This Mib object is deprecated and no longer supported.
| ||||
| SintEthernetInterfaceLocalIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.4 | IpAddress | RW | deprecated |
scalar · IpAddress · read-write · deprecated Contains the IP address for the MM side of the internal ethernet link. NOTE: This Mib object is deprecated and no longer supported. | ||||
| SintEthernetInterfaceDataRate | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.5 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, or Auto. NOTE: This Mib object is deprecated and no longer supported.
| ||||
| SintEthernetInterfaceDuplexSetting | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.6 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This Mib object is deprecated and no longer supported.
| ||||
| SintEthernetInterfaceLAA | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.7 | OCTET STRING (SIZE (17)) | RW | deprecated |
scalar · OCTET STRING (SIZE (17)) · read-write · deprecated Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: This Mib object is deprecated and no longer supported. | ||||
| SintEthernetInterfaceGatewayIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.9 | IpAddress | RW | deprecated |
scalar · IpAddress · read-write · deprecated Contains the IP address of the gateway/router for the ethernet interface. NOTE: This Mib object is deprecated and no longer supported. | ||||
| SintEthernetInterfaceBIA | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.10 | OCTET STRING (SIZE (17)) | RO | deprecated |
scalar · OCTET STRING (SIZE (17)) · read-only · deprecated Specifies the burned-in MAC (BIA) address. NOTE: This Mib object is deprecated and no longer supported. | ||||
| SintEthernetInterfaceMTU | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.13 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Contains the Maximum Transmission Unit (MTU) for the ethernet interface NOTE: This Mib object is deprecated and no longer supported. | ||||
| SintEthernetInterfaceSubnetMask | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.14 | IpAddress | RW | deprecated |
scalar · IpAddress · read-write · deprecated Contains the subnet mask for the ethernet interface. NOTE: This Mib object is deprecated and no longer supported. | ||||
| NstandbyExtEthernetInterface | 1.3.6.1.4.1.2.3.51.2.4.9.1.3 | |||
| SstandbyExtEthernetInterfaceType | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.1 | OCTET STRING (SIZE (0..16)) | RO | mandatory |
scalar · OCTET STRING (SIZE (0..16)) · read-only · mandatory The type of interface. Indicates 'Ethernet-1'. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyExtEthernetInterfaceHostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.3 | OCTET STRING (SIZE (0..64)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-write · mandatory Contains the 64 byte null terminated DNS host name for this interface. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyExtEthernetInterfaceIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.4 | IpAddress | RW | mandatory |
scalar · IpAddress · read-write · mandatory Contains the IP address for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyExtEthernetInterfaceDataRate | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G Auto or Auto. NOTE: This MIB object is only applicable to systems with a standby MM. Note that not all AMM hardware supports the 1G Auto speed. If it does not and a SET of this value is attempted, it will be rejected with a badValue return code. When a user selects the 1G Auto setting, the duplex setting will be forced to fullDuplex.
| ||||
| SstandbyExtEthernetInterfaceDuplexSetting | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.6 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This MIB object is only applicable to systems with a standby MM. When a user selects the 1G Auto speed setting, the duplex setting will be forced to fullDuplex.
| ||||
| SstandbyExtEthernetInterfaceLAA | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.7 | OCTET STRING (SIZE (17)) | RW | mandatory |
scalar · OCTET STRING (SIZE (17)) · read-write · mandatory Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: This MIB object is only applicable to systems with a standby MM. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup AMM, it is not recommended. | ||||
| SstandbyExtEthernetInterfaceDhcpEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.8 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable or enable DHCP on this interface. NOTE: This MIB object is only applicable to systems with a standby MM.
| ||||
| SstandbyExtEthernetInterfaceGatewayIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.9 | IpAddress | RW | mandatory |
scalar · IpAddress · read-write · mandatory Contains the IP address of the gateway/router for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyExtEthernetInterfaceBIA | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.10 | OCTET STRING (SIZE (17)) | RO | mandatory |
scalar · OCTET STRING (SIZE (17)) · read-only · mandatory Specifies the burned-in MAC (BIA) address. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyExtEthernetInterfaceMTU | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.13 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Contains the Maximum Transmission Unit (MTU) for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyExtEthernetInterfaceSubnetMask | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.14 | IpAddress | RW | mandatory |
scalar · IpAddress · read-write · mandatory Contains the subnet mask for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SadvancedFailover | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.15 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory User can enable advanced failover. off : no standby network interface ipswap: Standby network interface, swap IPs during failover ipnoswap: Standby network interface, no swap IPs during failover. NOTE: This MIB object is only applicable to systems with a standby MM.
| ||||
| NstandbyDhcpEthernetInterface | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16 | |||
| SstandbyDhcpHostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.1 | OCTET STRING (SIZE (0..64)) | RO | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyDhcpIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.2 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the IP address for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyDhcpGatewayIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.3 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyDhcpSubnetMask | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.4 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyDhcpDomainName | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.5 | OCTET STRING (SIZE (0..64)) | RO | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyDhcpDHCPServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.6 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the DHCP server IP address used to acquire the DHCP settings. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyDhcpPrimaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.7 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the Primary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyDhcpSecondaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.8 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the Secondary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SstandbyDhcpTertiaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.9 | IpAddress | RO | mandatory |
scalar · IpAddress · read-only · mandatory Contains the tertiary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| NextEthernetInterfaceIPv6 | 1.3.6.1.4.1.2.3.51.2.4.9.1.4 | |||
| SextEthernetInterfaceIPv6Type | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.1 | OCTET STRING (SIZE (0..16)) | RO | mandatory |
scalar · OCTET STRING (SIZE (0..16)) · read-only · mandatory The type of interface. Indicates 'Ethernet-1'. | ||||
| SextEthernetInterfaceIPv6Enabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The current IPv6 enabled or disabled state of this AMM. NOTE: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this AMM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces.
| ||||
| NextEthernetInterfaceIPv6Config | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5 | |||
| NextEthernetInterfaceIPv6LocalAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1 | |||
| SextEthernetInterfaceIPv6LinkLocalAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1.1 | InetAddressIPv6 | RO | mandatory |
scalar · InetAddressIPv6 · read-only · mandatory The IPv6 link local IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | ||||
| NextEthernetInterfaceIPv6StaticIPConfig | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2 | |||
| SextEthernetInterfaceIPv6StaticIPConfigEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The IPv6 static IP address enabled or disabled state for the ethernet interface.
| ||||
| SextEthernetInterfaceIPv6StaticIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.2 | InetAddressIPv6 | RW | mandatory |
scalar · InetAddressIPv6 · read-write · mandatory The IPv6 static IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | ||||
| SextEthernetInterfaceIPv6StaticIPAddressPrefixLen | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.3 | INTEGER (1..128) | RW | mandatory |
scalar · INTEGER (1..128) · read-write · mandatory The IPv6 static IP address prefix length for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value 0. | ||||
| SextEthernetInterfaceIPv6StaticIPDefaultRoute | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.4 | InetAddressIPv6 | RW | mandatory |
scalar · InetAddressIPv6 · read-write · mandatory The IPv6 static IP address default route for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | ||||
| NextEthernetInterfaceIPv6AutoIPConfig | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3 | |||
| SextEthernetInterfaceIPv6AutoIPConfigEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The IPv6 automatic IP configuration enabled or disabled state for the ethernet interface. NOTE: extEthernetInterfaceIPv6AutoIPConfigEnabled is the logical OR of extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled settings. NOTE: Enabling/Disabling extEthernetInterfaceIPv6AutoIPConfigEnabled will cause both extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled to be enabled/disabled. NOTE: extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6AutoIPConfigEnabled cannot be disabled at the same time.
| ||||
| NextEthernetInterfaceDHCPv6Config | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2 | |||
| SextEthernetInterfaceDHCPv6Enabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The DHCPv6 enabled or disabled state for the ethernet interface. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled is currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled. NOTE: If extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled are currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will not be allowed.
| ||||
| SextEthernetInterfaceDHCPv6IPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.2 | InetAddressIPv6 | RO | mandatory |
scalar · InetAddressIPv6 · read-only · mandatory The IPv6 address for the ethernet interface, assigned by DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | ||||
| SextEthernetInterfaceDHCPv6DomainName | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.4 | OCTET STRING (SIZE (0..64)) | RO | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory The 64 byte Domain Name for the ethernet interface, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '(Not available)'. | ||||
| SextEthernetInterfaceDHCPv6PrimaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.5 | InetAddressIPv6 | RO | mandatory |
scalar · InetAddressIPv6 · read-only · mandatory The primary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | ||||
| SextEthernetInterfaceDHCPv6SecondaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.6 | InetAddressIPv6 | RO | mandatory |
scalar · InetAddressIPv6 · read-only · mandatory The secondary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | ||||
| SextEthernetInterfaceDHCPv6TertiaryDNSServer | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.7 | InetAddressIPv6 | RO | mandatory |
scalar · InetAddressIPv6 · read-only · mandatory The tertiary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | ||||
| SextEthernetInterfaceDHCPv6Server | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.8 | InetAddressIPv6 | RO | mandatory |
scalar · InetAddressIPv6 · read-only · mandatory The DHCPv6 server IPv6 address used to acquire the DHCP settings. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | ||||
| NextEthernetInterfaceIPv6StatelessAutoConfig | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3 | |||
| SextEthernetInterfaceIPv6StatelessAutoConfigEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface. NOTE: If extEthernetfInterfaceDHCPv6Enabled is currently disabled, Disabling extEthernetInterfaceIPv6StatelessAutoConfigEnabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled.
| ||||
| TextEthernetInterfaceStatelessAutoConfigAddressesTable | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2 | NA | mandatory | |
table · not-accessible · mandatory Table of stateless Auto-Config addresses entries | ||||
| RextEthernetInterfaceStatelessAutoConfigAddressesEntry | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1 | NA | mandatory | |
row · not-accessible · mandatory Stateless Auto-Config address entries | ||||
| CextEthernetInterfaceStatelessAutoConfigAddressesIndex | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Index for stateless Auto-Config addresses. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. | ||||
| CextEthernetInterfaceStatelessAutoConfigAddresses | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.2 | InetAddressIPv6 | RO | mandatory |
column · InetAddressIPv6 · read-only · mandatory The stateless Auto-Configuration IPv6 address. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. | ||||
| CextEthernetInterfaceStatelessAutoConfigAddressesPrefixLen | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.3 | INTEGER (1..128) | RO | mandatory |
column · INTEGER (1..128) · read-only · mandatory The stateless Auto-Configration address prefix length. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. | ||||
| NstandbyExtEthernetInterfaceIPv6 | 1.3.6.1.4.1.2.3.51.2.4.9.1.5 | |||
| NstandbyEthernetInterfaceIPv6LocalAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.1 | |||
| SstandbyEthernetInterfaceIPv6LinkLocalAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.1.1 | InetAddressIPv6 | RO | mandatory |
scalar · InetAddressIPv6 · read-only · mandatory The IPv6 link local IP address for the standby AMM. | ||||
| NstandbyEthernetInterfaceIPv6StaticIPConfig | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2 | |||
| SstandbyEthernetInterfaceIPv6StaticIPConfigEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The IPv6 static IP address state for the AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPConfigEnabled object.
| ||||
| SstandbyEthernetInterfaceIPv6StaticIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.2 | InetAddressIPv6 | RW | mandatory |
scalar · InetAddressIPv6 · read-write · mandatory The IPv6 static IP address for the standby AMM NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | ||||
| SstandbyEthernetInterfaceIPv6StaticIPAddressPrefixLen | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.3 | INTEGER (1..128) | RO | mandatory |
scalar · INTEGER (1..128) · read-only · mandatory The IPv6 static IP address prefix length for the standyby AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPAddressPrefixLen object. | ||||
| SstandbyEthernetInterfaceIPv6StaticIPDefaultRoute | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.4 | InetAddressIPv6 | RO | mandatory |
scalar · InetAddressIPv6 · read-only · mandatory The IPv6 static IP address default route for the standby AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPDefaultRoute object. | ||||
| NstandbyEthernetInterfaceDHCPv6Config | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3 | |||
| SstandbyEthernetInterfaceDHCPv6Enabled | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The DHCPv6 enabled or disabled state for the standby AMM. NOTE: This field may be altered through the extEthernetInterfaceDHCPv6Enabled object.
| ||||
| SstandbyEthernetInterfaceDHCPv6IPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.2 | InetAddressIPv6 | RO | mandatory |
scalar · InetAddressIPv6 · read-only · mandatory The IPv6 address for the standby AMM assigned by DHCPv6 server. | ||||
| SstandbyEthernetInterfaceDHCPv6DomainName | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.4 | OCTET STRING (SIZE (0..64)) | RO | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-only · mandatory The 64 byte Domain Name for the standby AMM assigned by the DHCPv6 server. | ||||
| TstandbyEthernetInterfaceStatelessAutoConfigAddressesTable | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4 | NA | mandatory | |
table · not-accessible · mandatory Table of stateless Auto-Config addresses entries. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this table will show nothing. | ||||
| RstandbyEthernetInterfaceStatelessAutoConfigAddressesEntry | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1 | NA | mandatory | |
row · not-accessible · mandatory Stateless Auto-Config address entries | ||||
| CstandbyEthernetInterfaceStatelessAutoConfigAddressesIndex | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Index for stateless Auto-Config addresses. | ||||
| CstandbyEthernetInterfaceStatelessAutoConfigAddresses | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.2 | InetAddressIPv6 | RO | mandatory |
column · InetAddressIPv6 · read-only · mandatory The stateless Auto-Configuration IPv6 address. | ||||
| CstandbyEthernetInterfaceStatelessAutoConfigAddressesPrefixLen | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.3 | INTEGER (1..128) | RO | mandatory |
column · INTEGER (1..128) · read-only · mandatory The stateless Auto-Configration address prefix length. | ||||
| SddnsStatus | 1.3.6.1.4.1.2.3.51.2.4.9.1.10 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Dynamic DNS provides the capability for a networked device to notify a domain name server to change, in real time, the active DNS configuration of its configured hostnames, addresses or other information stored in DNS. With Dynamic DNS, host computers gain the capability to notify their respective DNS server of the IP address they have received from a DHCP server or through self-configuration.
| ||||
| ShostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.11 | OCTET STRING (SIZE (0..64)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-write · mandatory Contains the DNS host name for this system. This object provides the exact same function as extEthernetInterfaceHostName | ||||
| SstandbyHostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.12 | OCTET STRING (SIZE (0..64)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-write · mandatory Contains the DNS host name for the standby. This object provides the exact same function as standbyExtEthernetInterfaceHostName and is only applicable to systems with a standby MM. | ||||
| SdomainName | 1.3.6.1.4.1.2.3.51.2.4.9.1.13 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory The user assigned DNS domain name. | ||||
| SstandbyDomainName | 1.3.6.1.4.1.2.3.51.2.4.9.1.14 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory The user assigned DNS domain name of the standby. This is only applicable to systems with a standby MM. | ||||
| NvlanConfigure | 1.3.6.1.4.1.2.3.51.2.4.9.1.20 | |||
| SvlanGlobalState | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory This object disables or enables the VLAN feature. The configuration objects for the VLAN are in the table, vlanTable. The default setting for this object is disable(0). IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout.
| ||||
| SvlanCommitTimeout | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.2 | INTEGER (1..255) | RW | mandatory |
scalar · INTEGER (1..255) · read-write · mandatory This object is the number of minutes from the last VLAN-related object change until any non-committed changes will revert back to their previous settings. This means if a user makes a change that disrupts TCP/IP access to the CMM, the change will revert back to its previous setting after the number of minutes in this object. This allows the user to access the CMM again if access is lost through an unintended VLAN setting. Once the changes are committed using the object, vlanCommitState, setting it to executeCommit(3), the changes will be saved in non-volatile memory. The amount of time before uncommitted changes revert back to their previous settings starts from the last change made to any VLAN-related object. If no other change is made, the user has this number of minutes (the number in this object) to commit the changes with vlanCommitState before the changes will revert back. The default setting for this object is 2 minutes. IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout. | ||||
| SvlanCommitState | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory This object gives the status of whether there are VLAN-related changes pending that need to be committed, and allows a user to commit (save) any VLAN changes. If changes are pending, reading this object will give a value of commitNeeded(2). If no changes are pending, this object will have the value of noChangesPending(1). To save any VLAN-related changes so they do not revert back to previous settings, set this object to executeCommit(3) whenever this object has a value of commitNeeded(2).
| ||||
| TvlanTable | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20 | NA | mandatory | |
table · not-accessible · mandatory This table contains the VLAN configuration objects. The default entry has an vlanEntryIndex equal to 1. The objects for this default entry are configurable. An additional VLAN entry may be added by setting the object, vlanEntryStatus, at vlanEntryIndex=2 to the value of createRequest(2) and also setting the object, vlanEntryVlanId, at vlanEntryIndex=2 to a valid, unique value. IMPORTANT NOTE: Any changes to the object of this table will revert back to their previous settings if the changes are not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout. | ||||
| RvlanEntry | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1 | NA | mandatory | |
| CvlanEntryIndex | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.1 | INTEGER (1..2) | RO | mandatory |
column · INTEGER (1..2) · read-only · mandatory Index for VLAN entry. If vlanEntryIndex is equal to 1, it is the Default VLAN entry and cannot be deleted. | ||||
| CvlanEntryVlanId | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.2 | INTEGER (1..4094) | RW | mandatory |
column · INTEGER (1..4094) · read-write · mandatory Valid VLAN ID. Allowed values are 1..4094. If the entry is not valid, this object will have the value of 0. If this entry has the vlanEntryIndex value of 1 (default VLAN entry), then setting this object will take effect immediately. For other entries, when this object is set, this entry must have the object, vlanEntryState set to enable(1) or restart(2) for this change to take effect. | ||||
| CvlanEntryName | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.3 | OCTET STRING (SIZE (0..31)) | RW | mandatory |
column · OCTET STRING (SIZE (0..31)) · read-write · mandatory This object allows the user to configure a text string name for this VLAN entry. This entry name is only used as a label for this entry. | ||||
| CvlanEntryStatus | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.4 | EntryStatus | RW | mandatory |
column · EntryStatus · read-write · mandatory This object manages the creation and deletion of this
entry.
The steps recommended to add a new VLAN entry are:
1. Create a new entry in this table
vlanEntryStatus = createRequest
2. Set vlanEntryVlanId as required.
Then the entry will be valid.
valid(1) - Indicates that this entry is available
for use.
createRequest(2) - A new entry will be created in this
table and will transition to the
vlanEntryStatus value of
underCreation(3).
underCreation(3) - Indicates that this entry exists in the
agent but is unavailable for use. After
completing the create operation, the
agent will set this object to the value
underCreation(3).
invalid(4) - Deletes this entry.
The entry with the vlanEntryIndex value of 1 (default VLAN
entry) cannot be deleted. | ||||
| CvlanEntryState | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.5 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory This object indicates whether this VLAN entry is enabled or disabled and allows the user to disable, enable or restart this entry except for the exceptions noted below. The entry with a vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to enable(1) and cannot be set to any other value. Other table entries do not have this restriction. Some other objects in this table may not take effect after a change until either this object is: set to enable(1) if this object currently has the value of disable(0), or set to restart(2) if this object currently has the value of enable(1). The other objects in this table that require this object be set to enable(1) or restart(2) after a change are noted in the description for those objects.
| ||||
| CvlanEntrySOLAccess | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory This object allows the user to set whether the VLAN for this entry will have access to the Serial Over LAN (SOL) interface. Only one VLAN entry may have this object set to enable(1). By default, the entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to enable(1). To set this object to enable(1) on another entry, this object must first be set to disable(0) on any entry that has this object set to enable(1).
| ||||
| CvlanEntrycKVMAccess | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory This object allows the user to set whether the VLAN for this entry will have access to the installed cards for concurrent keyboard, video, and mouse (cKVM). Only one VLAN entry may have this object set to enable(1). By default, the entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to enable(1). To set this object to enable(1) on another entry, this object must first be set to disable(0) on any entry that has this object set to enable(1).
| ||||
| CvlanEntryTagging | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory This object allows the user to set whether VLAN tagging is enabled for this VLAN entry. This object is only configurable for the entry with the vlanEntryIndex value of 1. By default, the entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to disable(0), all other entries will have this object set to enable(1).
| ||||
| CvlanEntryIOModuleAccess | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory This read-only object indicates whether the VLAN for this entry will have access to the IO Modules. Only the VLAN entry with the vlanEntryIndex value of 1 will report this object with the value of enable(1), all other entries will have a value of disable(0).
| ||||
| CvlanEntryVlanDefault | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.10 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory This object specifies which vlanTable entry is the 'default entry'. By default, the entry with the vlanEntryIndex value of 1 will have this object set to true(1). Only one vlanTable entry can be designated as the VLAN default entry. Setting this object to true(1) for an entry will make this object false(0) for all other vlanTable entries. Only the vlanTable entry with this object set to true(1) will allow the vlanEntryTagging object to be configurable for this vlanEntryIndex index.
| ||||
| CvlanEntryIPv4StaticAddress | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.31 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory This object sets the IP address for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | ||||
| CvlanEntryIPv4StaticGateway | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.32 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory This object sets the IP address for the IP gateway for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the IP gateway for the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP gateway of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | ||||
| CvlanEntryIPv4StaticMask | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.33 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory This object sets the subnet mask for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the subnet mask of the ethernet interface. The subnet mask of the default VLAN entry can only change by changing the subnet mask of the ethernet interface. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | ||||
| CvlanEntryIPv4SubnetRoute1 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.51 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory This object sets the IP address of the subnet route 1 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | ||||
| CvlanEntryIPv4SubnetRouteMask1 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.52 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory This object sets the subnet route mask 1 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | ||||
| CvlanEntryIPv4SubnetRoute2 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.53 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory This object sets the IP address of the subnet route 2 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | ||||
| CvlanEntryIPv4SubnetRouteMask2 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.54 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory This object sets the subnet route mask 2 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | ||||
| CvlanEntryIPv4SubnetRoute3 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.55 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory This object sets the IP address of the subnet route 3 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | ||||
| CvlanEntryIPv4SubnetRouteMask3 | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.56 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory This object sets the subnet route mask 3 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | ||||
| NtcpProtocols | 1.3.6.1.4.1.2.3.51.2.4.9.3 | |||
| NsnmpAgentConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.1 | |||
| SsnmpSystemContact | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.1 | OCTET STRING (SIZE (0..48)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..48)) · read-write · mandatory A NULL terminated 48 byte string that contains the SNMP agent contact name. | ||||
| SsnmpSystemLocation | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.2 | OCTET STRING (SIZE (0..48)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..48)) · read-write · mandatory A NULL terminated 48 byte string that contains the SNMP agent location name. | ||||
| SsnmpSystemAgentTrapsDisable | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable or enable SNMP traps.
| ||||
| NsnmpAgentCommunityConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4 | |||
| TsnmpCommunityTable | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1 | NA | mandatory | |
table · not-accessible · mandatory Table of SNMP Community entries | ||||
| RsnmpCommunityEntry | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1 | NA | mandatory | |
| CsnmpCommunityEntryIndex | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.1 | INTEGER (0..255) | RO | mandatory |
column · INTEGER (0..255) · read-only · mandatory Index for SNMP Agent Community entry. | ||||
| CsnmpCommunityEntryCommunityName | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.2 | OCTET STRING (SIZE (0..15)) | RW | mandatory |
column · OCTET STRING (SIZE (0..15)) · read-write · mandatory SNMP Community entry name. | ||||
| CsnmpCommunityEntryCommunityIpAddress1 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.3 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | ||||
| CsnmpCommunityEntryCommunityIpAddress2 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.4 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | ||||
| CsnmpCommunityEntryCommunityIpAddress3 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.5 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | ||||
| CsnmpCommunityEntryCommunityViewType | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Access Level of the SNMPv1 managers. Note this parameter is set for each community. Therefore all three managers in the same community have the same access level.
| ||||
| CsnmpCommunityEntryCommunityIpAddress4 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.7 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | ||||
| CsnmpCommunityEntryCommunityIpAddress5 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.8 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | ||||
| CsnmpCommunityEntryCommunityIpAddress6 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.9 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | ||||
| CsnmpCommunityEntryCommunityIpAddress7 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.10 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | ||||
| CsnmpCommunityEntryCommunityIpAddress8 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.11 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | ||||
| CsnmpCommunityEntryCommunityIpAddress9 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.12 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | ||||
| CsnmpCommunityEntryCommunityIpAddress10 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.13 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | ||||
| CsnmpCommunityEntryCommunityIpAddress11 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.14 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | ||||
| CsnmpCommunityEntryCommunityIpAddress12 | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.15 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | ||||
| Ssnmpv1SystemAgentEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable or enable the SNMPv1 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv1 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor adaptor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact (2) Is there a valid system name (3) Is there at least one valid community name and for that community name is there one valid IP address or hostname (4) Are all defined community names unique If this verification fails an error response will be returned and the SNMPv1 agent will be left disabled.
| ||||
| Ssnmpv3SystemAgentEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.6 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable or enable the SNMPv3 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv3 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor adaptor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact? (2) Is there a valid system name? If this verification fails an error response will be returned and the SNMPv3 agent will be left disabled.
| ||||
| NsnmpAgentUserProfileConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9 | |||
| TsnmpUserProfileTable | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1 | NA | mandatory | |
table · not-accessible · mandatory Table of SNMPv3 User Profile entries | ||||
| RsnmpUserProfileEntry | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1 | NA | mandatory | |
| CsnmpUserProfileEntryIndex | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.1 | INTEGER (0..255) | RO | mandatory |
column · INTEGER (0..255) · read-only · mandatory Index for SNMPv3 Agent User Profile entry. | ||||
| CsnmpUserProfileEntryContextName | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.3 | OCTET STRING (SIZE (0..31)) | RW | mandatory |
column · OCTET STRING (SIZE (0..31)) · read-write · mandatory SNMPv3 User Profile entry - Context name for users to access MIB objects. Note that context names can be duplicates and can be shared among users. Empty context names are allowed. The default context name is the empty string. | ||||
| CsnmpUserProfileEntryAuthProt | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory SNMPv3 User Profile entry - Authentication Protocol supported by the user.
| ||||
| CsnmpUserProfileEntryPrivProt | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory SNMPv3 User Profile entry - Privacy Protocol supported by the user. The Privacy Password must be set and the Authentication Protocol must be md5 or sha before this field may be set to des or aes.
| ||||
| CsnmpUserProfileEntryPrivPassword | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.7 | OCTET STRING (SIZE (0..31)) | RW | mandatory |
column · OCTET STRING (SIZE (0..31)) · read-write · mandatory SNMPv3 User Profile entry - Privacy password for the user. NOTE: Value returned for the GET command is meaningless for this MIB object for security reasons. | ||||
| CsnmpUserProfileEntryViewType | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory SNMPv3 User Profile entry - Access level (Get, Set, and Traps) of the user.
| ||||
| CsnmpUserProfileEntryIpAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.9 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory SNMPv3 User Profile entry - IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. | ||||
| NdnsConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.2 | |||
| SdnsEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable or enable the DNS agent. NOTE: To alter any of the configuration settings for the DNS agent, the following procedure should be used: (1) This object should be set to 'disabled' (2) Make the modifications to other settings (3) This object should be set to 'enabled' (4) Restart the management module Also note that when attempting to enable this agent, it is verified that there is at least one valid DNS server IP address. If this verification fails, an error response will be returned and the DNS agent will be left disabled.
| ||||
| SdnsServerIPAddress1 | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.2 | IpAddress | RW | mandatory |
scalar · IpAddress · read-write · mandatory Contains the primary DNS server IP address. | ||||
| SdnsServerIPAddress2 | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.3 | IpAddress | RW | mandatory |
scalar · IpAddress · read-write · mandatory Contains the secondary DNS server IP address. | ||||
| SdnsServerIPAddress3 | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.4 | IpAddress | RW | mandatory |
scalar · IpAddress · read-write · mandatory Contains the tertiary DNS server IP address. | ||||
| SdnsServerIPv6Address1 | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.12 | InetAddressIPv6 | RW | mandatory |
scalar · InetAddressIPv6 · read-write · mandatory Contains the primary IPv6 DNS server address. | ||||
| SdnsServerIPv6Address2 | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.13 | InetAddressIPv6 | RW | mandatory |
scalar · InetAddressIPv6 · read-write · mandatory Contains the secondary IPv6 DNS server address. | ||||
| SdnsServerIPv6Address3 | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.14 | InetAddressIPv6 | RW | mandatory |
scalar · InetAddressIPv6 · read-write · mandatory Contains the tertiary IPv6 DNS server address. | ||||
| SdnsPriority | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.20 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Tells the order host names are resolved. The options are to either first resolve with an IPv6 DNS server or to first resolve with an IPv6 DNS server.
| ||||
| NsmtpConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.3 | |||
| SsmtpServerNameOrIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.3.1 | OCTET STRING (SIZE (0..64)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-write · mandatory A NULL terminated 64 byte string that contains the SMTP server host name or IP address (a.b.c.d). | ||||
| SattachmentsToEmailAlerts | 1.3.6.1.4.1.2.3.51.2.4.9.3.3.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Indicates if the service information should be attached to an email alert.
| ||||
| SsmtpEmailDomain | 1.3.6.1.4.1.2.3.51.2.4.9.3.3.3 | OCTET STRING (SIZE (0..64)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-write · mandatory A NULL terminated string that contains the SMTP email domain. If this field is empty, the AMM IP address is used as the domain. However, some SMTP servers (e.g. - MS Exchange 2007) do not accept an IP address and instead require a domain name. This object can be used to set that email domain name. | ||||
| NtcpApplicationConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.4 | |||
| StelnetInactivityTimeout | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Default is 120 seconds. Value of zero is no timeout. Max value is any positive 4 bytes value. Note that SSH also uses this timeout value to wait before disconnecting inactive SSH connections. | ||||
| ScommandModeInactivityTimeout | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The amount of time in seconds before the (Secure)TCP Command Mode times out. Default value of 0 means no timeout. Max value is any positive 4 byte value. | ||||
| SsecureCommandModeEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Set Secure TCP Command Mode number of connections. AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled. If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable. NOTE: System Management Software requires this to be enabled for secure communication to the AMM. | ||||
| ScommandModeEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Set TCP Command Mode number of connections. AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled. NOTE: System Management Software requires this to be enabled for non-secure communication to the AMM. | ||||
| SslpAddrType | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Set SLP address type to 0 (multicast) or 1 (broadcast). Note that when slpAddrType is set to broadcast value then the multicast address set in slpMulticastAddr will be ignored.
| ||||
| SslpMulticastAddr | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.6 | IpAddress | RW | mandatory |
scalar · IpAddress · read-write · mandatory Service Locator Protocol Multicast address | ||||
| SslpEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.7 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable Service Location Protocol. NOTE: Change to Service Location Protocol will take effect after the next restart of the MM.
| ||||
| StelnetEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.9 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable telnet. NOTE: Change to telnet enable/disable will take effect immediately.
| ||||
| SsshEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.10 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable SSH.
| ||||
| SsshVersion | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.11 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory When SSH is enabled, this object allows the user to configure whether the SSH server accepts all versions of client connections or whether it restricts the connectivity to the more secure version 2 only. NOTE: Only SSH version 2 is supported now.
| ||||
| SsslServerEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.15 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable SSL Server.
| ||||
| SsslClientEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.16 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable SSL Client. If no valid client or server certificate is in place, SSL client will not be allowed to set to enable.
| ||||
| SftpEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.17 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable FTP.
| ||||
| StftpEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.19 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable TFTP.
| ||||
| SsmashTelnetEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.20 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over Telnet. This option is not available on all systems.
| ||||
| SsmashSshEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.21 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over SSH. A valid SSH server key must be installed before enabling secure SMASH. This option is not available on all systems.
| ||||
| StftpCreateEmptyFile | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.22 | OCTET STRING | RW | deprecated |
scalar · OCTET STRING · read-write · deprecated This MIB object is no longer a requirement for TFTP and has been deprecated. | ||||
| SftpTimeout | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.23 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The amount of time before FTP times out. Default is 300 seconds. Value of zero is no timeout. Max value is any positive 4 byte value. | ||||
| SrdEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.24 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable Remote Disk. NOTE: Change to Remote Disk will take effect after the next restart of the MM.
| ||||
| SrdocEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.25 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable Remote Disk on Card. NOTE: Change to Remote Disk on Card will take effect after the next restart of the MM.
| ||||
| SkvmEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.26 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable KVM. NOTE: Change to KVM will take effect after the next restart of the MM.
| ||||
| NmmSshServerConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27 | |||
| TmmSshServerHostKeyTable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1 | NA | mandatory | |
table · not-accessible · mandatory A table that contains per public/private host key pair information. | ||||
| RmmSshServerHostKeyEntry | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1 | NA | mandatory | |
row · not-accessible · mandatory A list of information about a particular public/private host key pair. | ||||
| CmmSshServerHostKeyIndex | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The index of the public/private host key pair. | ||||
| CmmSshServerHostKeyType | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The type of the public/private host key pair.
| ||||
| CmmSshServerHostKeySize | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The size of the public/private host key pair. NOTE: The AMM supports only the bits2048 value.
| ||||
| CmmSshServerHostKeyFingerprint | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The RSA fingerprint of the public part of the host key pair. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the AMM. | ||||
| SmmSshServerHostKeyGenerate | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Initiate the new Host Keys generation process for the AMM SSH Server. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SmmSshServerHostKeyGenerateProgress | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.3 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Indicate the progress of the key generation process. | ||||
| SrpEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.28 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable Remote Presence.
| ||||
| NtcpPortAssignmentCfg | 1.3.6.1.4.1.2.3.51.2.4.9.3.5 | |||
| StcpPortsRestoreDefault | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reset all ports to default value. http: 80 https: 443 telnet: 23 ssh: 22 SNMP agent: 161 SNMP trap: 162 TCP Command Mode: 6090 Secure TCP Command Mode: 6091 Remote Disk: 1044 Remote Disk-on-Card: 1045 Remote KVM: 3900 FTP: 21 FTP Data: 20 TFTP: 69 SMASH telnet: 50023 SMASH ssh: 50022 SLP: 427 Storage Description Service: 1046 NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| ShttpPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory HTTP port number. Default value is 80. Once changed, the URL's have to include :port at the end. | ||||
| ShttpsPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory SSL port number. Default value is 443. Once changed, the URL's have to include :port at the end. | ||||
| StelnetPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Telnet port number. Default value is 23. Port change will take effect immediately. | ||||
| SsshPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory SSH port number. Default value is 22. | ||||
| SsnmpAgentPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.6 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory SNMP Agent port number. Default value is 161. Changes take effect after several seconds. | ||||
| SsnmpTrapsPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.7 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory SNMP Traps port number. Default value is 162. Changes take effect after several seconds. | ||||
| ScommandModePortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.8 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory TCP Command Mode port number. Default value is 6090. Change will take effect immediately. | ||||
| SsecureCommandModePortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.9 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Secure TCP Command Mode port number. Default value is 6091. Change will take effect immediately. | ||||
| SrdPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.10 | INTEGER | RW | deprecated |
scalar · INTEGER · read-write · deprecated Remote Disk port number. Default value is 1044. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information. | ||||
| SrdocPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.11 | INTEGER | RW | deprecated |
scalar · INTEGER · read-write · deprecated Remote Disk-on-Card port number. Default value is 1045. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information. | ||||
| SkvmPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.12 | INTEGER | RW | deprecated |
scalar · INTEGER · read-write · deprecated Remote KVM port number. Default value is 3900. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information. | ||||
| SftpPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.13 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory FTP port number. Default value is 21. Port change will take effect immediately. | ||||
| SftpDataPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.14 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory FTP Data port number. Default value is 20. Port change will take effect immediately. | ||||
| StftpPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.15 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory TFTP port number. Default value is 69. | ||||
| SsmashTelnetPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.17 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The port number for SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over telnet. Default value is 50023. Change will take effect immediately. This option is not available on all systems. | ||||
| SsmashSshPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.18 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The port number for SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over SSH. Default value is 50022. This option is not available on all systems. | ||||
| SslpPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.19 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Service Location Protocol port number. Default value is 427. NOTE: This value is normally required to be 427 to interoperate properly with other SLP enabled applications. | ||||
| SsdsPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.20 | INTEGER | RW | deprecated |
scalar · INTEGER · read-write · deprecated Storage description service port number. Default value is 1046. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information. | ||||
| SrpPortAssignment | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.21 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Remote Presence port. Default value is 3900. This port cannot be disabled since it is the single service entry point for all the services provided by AMM RPServ to clients. | ||||
| NldapClientCfg | 1.3.6.1.4.1.2.3.51.2.4.9.3.6 | |||
| SldapServer1NameOrIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.1 | OCTET STRING (SIZE (0..256)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..256)) · read-write · mandatory A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). | ||||
| SldapServer1PortNumber | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory LDAP server port number. | ||||
| SldapServer2NameOrIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.3 | OCTET STRING (SIZE (0..256)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..256)) · read-write · mandatory A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). | ||||
| SldapServer2PortNumber | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory LDAP server port number. | ||||
| SldapServer3NameOrIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.5 | OCTET STRING (SIZE (0..256)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..256)) · read-write · mandatory A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). | ||||
| SldapServer3PortNumber | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.6 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory LDAP server port number. | ||||
| SldapRootDN | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.7 | OCTET STRING (SIZE (0..256)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..256)) · read-write · mandatory A NULL terminated 255 byte string that contains the distinguished Name for root entry of directory tree. An example might look like dn=foobar,dn=com. | ||||
| SldapUserSearchBaseDN | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.8 | OCTET STRING (SIZE (0..255)) | RW | deprecated |
scalar · OCTET STRING (SIZE (0..255)) · read-write · deprecated As part of the user authentication process, it is necessary to search the LDAP server for one or more attributes associated with a particular user. Any search request must specify the base DN for the actual search. This field specifies the base DN which should be used to search the User directory. This is a NULL terminated 255 byte string. An example might look like cn=users,dn=foobar,dn=com. If this field is left blank, the Root DN will be used as the search base instead. As mentioned, user searches are part of the authentication process. They are carried out to retrieve information about the user such as login permissions, callback number, and group memberships. For Version 2.0 LDAP clients, it is strongly encouraged that this parameter be configured, otherwise a search using the root DN may not succeed (as seen on Active Directory servers). NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | ||||
| SldapGroupFilter | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.9 | OCTET STRING (SIZE (0..511)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..511)) · read-write · mandatory This filter is used for group authentication. It specifies what group or groups that this MM belongs to. If left blank, group authentication is disabled. Otherwise, group authentication will be performed against the filter. The filter can be a specific group name (e.g. RSAWest), a wildcard (*) which matches everything, or a wildcard with a prefix (e.g. RSA*). The default filter is RSA*. After user authentication, group authentication will take place, whereby an attempt will be made to match the group or groups (that the user belongs to) to the group filter defined here. If there is no match, the user will not pass authentication and will be blocked. If there is a match, the login permissions for the user will be retrieved from the matched group(s), unless the user already has login permissions assigned directly from the user record retrieved from the LDAP server. | ||||
| SldapBindingMethod | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.10 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory On initial binds to the LDAP server during user authentication, there are three options: Anonymous authentication: Bind attempt is made without a client DN or password. If the bind is successful, a search will be requested in order to find an entry on the LDAP server for the user attempting to login. If an entry is found, a second attempt to bind will be attempted, this time with the user's DN and password. If this succeeds, the user is deemed to have passed the user authentication phase. Group authentication is then attempted if it is enabled. Client authentication: Bind attempt is made with client DN and password specified by this configuration parameter. If the bind is successful, we proceed as above. User Principal Name (UPN): Bind attempt is made directly with the credentials used during the login process. If this succeeds, the user is deemed to have passed the user authentication phase. Note that for Active Directory servers, the userid can have the form someuser@somedomain or simply someuser. Strict UPN: This is the same as UPN above, except that the userid must have the form someuser@somedomain. The string entered by the user will be parsed for the @ symbol. NOTE: strictUserPrincipalName(3) option is available on MM only.
| ||||
| SldapClientAuthenticationDN | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.11 | OCTET STRING (SIZE (0..255)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..255)) · read-write · mandatory The initial bind to the LDAP server during user authentication can be performed with anonymous authentication, client based authentication, or UPN. The client based option requires a client DN and password as parameters to the bind request. The client DN is a NULL terminated 255 byte string. These parameters are configured here. Note that the password can be left blank. | ||||
| SldapClientAuthenticationPassword | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.12 | OCTET STRING (SIZE (0..16)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..16)) · read-write · mandatory The client authentication password | ||||
| SldapUIDsearchAttribute | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.13 | OCTET STRING (SIZE (0..64)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-write · mandatory When the binding method selected is Anonymous authentication or Client authentication, the initial bind to the LDAP server is followed by a search request aimed at retrieving specific information about the user, including the user's DN, login permissions, and group ownerships. In order to retrieve this information, the search request must specify the attribute name used to represent userids on that server. Specifically, this name is used as a search filter against the login id entered by the user. This attribute name is configured here. If this field is left blank, a default of uid is used during user authentication. For example, on Active Directory servers, the attribute name used for userids is often sAMAccoutName. When the binding method selected is UPN or Strict UPN, this field defaults automatically to userPrincipalName during user authentication if the userid entered has the form userid@somedomain. | ||||
| SldapGroupSearchAttribute | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.14 | OCTET STRING (SIZE (0..64)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-write · mandatory When the MM Group Filter name is configured, it is necessary to retrieve from the LDAP server the list of groups that a particular user belongs to. This is required to do group authentication. In order to retrieve this list, the search filter sent to the server must specify the attribute name associated with groups. This field specifies this attribute name. If this field is left blank, the attribute name in the filter will default to memberOf. | ||||
| SldapLoginPermissionAttribute | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.15 | OCTET STRING (SIZE (0..64)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-write · mandatory When a user successfully authenticates via a LDAP server, it is necessary to retrieve the login permissions for this user. In order to retrieve these permissions, the search filter sent to the server must specify the attribute name associated with login permissions. This field specifies this attribute name. | ||||
| SldapUseDNSOrPreConfiguredServers | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.16 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The MM contains a Version 2.0 LDAP Client that may be configured to provide user authentication through one or more LDAP servers. The LDAP server(s) to be used for authentication can be discovered dynamically or manually pre-configured. If the usePreConfiguredLDAPServers option is selected, up to 4 LDAP servers can be configured. Simply enter the server's IP address or hostname (assuming DNS is enabled). The port number for each server is optional. If left blank, the default value of 389 is used for non-secured LDAP connections. For secured connections, the default is 636. At least one server must be configured. If the useDNSToFindLDAPServers is selected, the domain name need to be provided. For LDAP Authentication Only mode, additional information such as the forest name also need to be provided.
| ||||
| SldapDomainSource | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.17 | INTEGER | RW | deprecated |
scalar · INTEGER · read-write · deprecated The DNS SRV request sent to the DNS server must specify a domain name. The LDAP client will determine where to get this domain name based on one of the following three options: - extractSearchDomainFromLoginID: With this option, the LDAP client will use the domain name in the login id. For example, if the login id is [email protected], the domain name equals mycompany.com. If the domain name cannot be extracted, the DNS SRV will fail, causing the user authentication to fail automatically. - useOnlyConfiguredSearchDomainBelow: With this option, the LDAP client will use the domain name configured in the Search Domain parameter. - tryLoginFirstThenConfiguredValue: With this option, the LDAP client will first attempt to extract the domain name from the login id. If this succeeds, this domain name will be used in the DNS SRV request. If there is no domain name present in the login id, the LDAP client will instead use the configured Search Domain parameter as the domain name in the DNS SRV request. If nothing is configured, user authentication will fail immediately.
| ||||
| SldapSearchDomain | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.18 | OCTET STRING (SIZE (0..64)) | RW | deprecated |
scalar · OCTET STRING (SIZE (0..64)) · read-write · deprecated This parameter may be used as the domain name in the DNS SRV request, depending on how the Domain Source parameter is configured. | ||||
| SldapServiceName | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.19 | OCTET STRING (SIZE (0..16)) | RW | deprecated |
scalar · OCTET STRING (SIZE (0..16)) · read-write · deprecated The DNS SRV request sent to the DNS server must also specify a service name. The configured value will be used for this purpose. If left blank, the default value used is 'ldap'. Note that the DNS SRV request must also specify a protocol name. This defaults to 'tcp' and is not configurable. | ||||
| SldapRBSModelCfg | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.20 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory There are two mechanisms to authenticate and authorize users on the AMM when using an LDAP-enabled server. The first mechanism (oldPermissionString), also known as version 1, uses bitstrings to associate permissions to users and groups. Version1 supports Active Directory, Novell eDirectory, and OPenLDAP based servers. The second mechanism (newRBSModel), also known as version 2, uses a new Role-Based-Security (RBS) model. This mechanism is only available for Active Directory servers, and requires the use of a snap-in that runs on any windows platform. This snap-in tool allows you to configure roles on an Active Directory server of your choice, and to associate users/groups and AMMs to those roles. A role identifies the permissions given to users and groups associated with that role, and also identifies the targets (e.g. AMM) to which this role is attached. The use of bitstrings in version 2 disappears, making the configuration much more manageable and user-friendly. Note that if you are not using Active Directory, then you should not enable version 2. Also note that before enabling version 2, you should already have your roles configured on your Active Directory server. The old version 1 bitstring model cannot be automatically converted to the new version 2 model. This is why you must configure your users and groups before enabling version 2. Once enabled, the change takes effect immediately. The default value for this field is oldPermissionString.
| ||||
| SldapTargetName | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.21 | OCTET STRING (SIZE (0..16)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..16)) · read-write · mandatory When administrator chooses Enhanced Role Based Security authentication model, he can associate one AMM with one managed target object in Snap-in (one tool to configure LDAP users permission) via one target name. The AMM target name can be looked as alias of AMM, administrator can change it according to his configuration requirements. This is a string of up to 63 characters (plus the null character) | ||||
| SldapAuthCfg | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.22 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory If ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize users. If it is set to 1, LDAP server is only used to authenticate users. Note:LDAP Authentication Only mode is currently supported only in an Active Directory environment.
| ||||
| SldapForestName | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.23 | OCTET STRING (SIZE (0..64)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..64)) · read-write · mandatory LDAP Forest Name. Note: LDAP Forest Name is only for Active Directory environment. | ||||
| SldapDomainName | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.24 | OCTET STRING (SIZE (0..256)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..256)) · read-write · mandatory A NULL terminated 255 byte string that contains the LDAP Domain Name. | ||||
| SldapServer4NameOrIPAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.25 | OCTET STRING (SIZE (0..256)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..256)) · read-write · mandatory A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). | ||||
| SldapServer4PortNumber | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.26 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory LDAP server port number. | ||||
| NuplinkCheckConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.7 | |||
| SuplinkCheckEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable or enable network uplink checking for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM.
| ||||
| SuplinkCheckDelay | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Delay, in minutes (1-2880), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SlogicalUplinkDestination | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.3 | IpAddress | RW | mandatory |
scalar · IpAddress · read-write · mandatory Destination IP for MM to check its logical link. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SlogicalUplinkCheckEnabled | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable or enable network uplink checking for logical detection. logicalUplinkDestination must be set to a non-zero IP Address before enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM.
| ||||
| SlogicalUplinkCheckDelay | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Delay, in minutes(1-2880), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SphysicalUplinkCheckDelayInSecs | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.6 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Delay, in seconds(10-172800), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SlogicalUplinkCheckDelayInSecs | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.7 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Delay, in seconds(60-172800), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | ||||
| SlogicalUplinkIPv6Destination | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.8 | InetAddressIPv6 | RW | mandatory |
scalar · InetAddressIPv6 · read-write · mandatory Destination IP for MM to check its logical link using IPv6. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM. NOTE: This MIB object is only applicable if IPv6 is enabled on the MM. | ||||
| SlogicalUplinkFailoverPolicy | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.9 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Determines when to failover if both an IPv4 and IPv6 destination have been configured. If set to 'either' the system will failover if either of the destination's link check fails. If set to 'both' then the IPv4 and IPv6 link checks must fail before a failover will happen. NOTE: This MIB object is only applicable to systems with a standby MM.
| ||||
| NntpConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.8 | |||
| SntpEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable the NTP client. The client will update the AMM system clock at the frequency specified.
| ||||
| SntpIpAddressHostname | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.2 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..63)) · read-write · mandatory NTP server's IP address or hostname if DNS is enabled and configured. | ||||
| SntpUpdateFrequency | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The frequency in minutes that the NTP service runs. The value range is 0 to 45000. If the NTP update frequency is set to 0, the AMM clock can only be synchronized with the NTP server manually. | ||||
| SntpLastUpdate | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.4 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The date and time that the NTP server last updated the system clock. | ||||
| SntpUpdateClock | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Update the AMM system clock with the specified NTP server. A valid NTP server must be configured first.
| ||||
| SntpAuthEntry | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.6 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory The NTP v3 authentication entry to be used for time sync with a secure NTP server. The format of an authentication entry is <key index> <key type> <key>. <key index> must be an integer between 1 and 65535. <key type> must be M. <key> is the actual value of the authentication key as configured on the NTP server. The GET command returns back data in the format: <key index> <key type> It does not return the actual key. | ||||
| SntpAuthEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.7 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Enables/Disables NTP v3 authentication
| ||||
| NsyslogConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.9 | |||
| SsyslogSevFilterLevel | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory syslogSevFilterLevel error/warning/information .
| ||||
| NsyslogCollectorConfig | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2 | |||
| TsyslogCollectorTable | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1 | NA | mandatory | |
table · not-accessible · mandatory Table of Syslog Collector entries | ||||
| RsyslogCollectorEntry | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1 | NA | mandatory | |
| CsyslogCollectorIndex | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.1 | INTEGER (0..255) | RO | mandatory |
column · INTEGER (0..255) · read-only · mandatory Index for Syslog Collector entry. | ||||
| CsyslogCollectorHostnameOrIpAddress | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.2 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
column · OCTET STRING (SIZE (0..63)) · read-write · mandatory Syslog Collector IP address or host name. | ||||
| CsyslogCollectorPort | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.3 | INTEGER (1..65535) | RW | mandatory |
column · INTEGER (1..65535) · read-write · mandatory Syslog Collector port number. | ||||
| CsyslogCollectorEnable | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Syslog Collector enable/disable.
| ||||
| SsyslogTestPacket | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Generate a test syslog packet. This will send a test syslog to all configured
and enabled syslog collectors to assist in validating the configuration.
NOTE: Value returned for the GET command is meaningless for this
MIB object.
| ||||
| NsolConfiguration | 1.3.6.1.4.1.2.3.51.2.4.10 | |||
| NsolGlobalConfig | 1.3.6.1.4.1.2.3.51.2.4.10.1 | |||
| SsolEnable | 1.3.6.1.4.1.2.3.51.2.4.10.1.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable SOL dynamically.
| ||||
| SsolVlanId | 1.3.6.1.4.1.2.3.51.2.4.10.1.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory This is the virtual LAN ID for the internal management network between the MM and the Blade System Management Processors (BSMPs). The range of valid VLAN ID's is 3 to 4095. | ||||
| SsolAccumulateTimeout | 1.3.6.1.4.1.2.3.51.2.4.10.1.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory This value specifies how much time in millisecond SOL to buffer data before sending the next SOL packet since the last SOL packet was transmitted. Valid value from 5 ms to 1275 ms. The value is in 5 ms increment. Value is not in 5 ms increment will be truncated to a nearest 5s. Default value is 5 ms. | ||||
| SsolCharSendThreshold | 1.3.6.1.4.1.2.3.51.2.4.10.1.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory This value specifies how many characters SOL to buffer before sending the next SOL packet since the last SOL packet was transmitted. Valid value is from 1 to 255 | ||||
| SsolRetry | 1.3.6.1.4.1.2.3.51.2.4.10.1.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Retry count. Valid value from 0-7. 0 means no retries after packet is transmitted. Packet will be dropped if no ACK/NACK received by the time retries expired. | ||||
| SsolRetryInterval | 1.3.6.1.4.1.2.3.51.2.4.10.1.6 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Retry Interval in 10 ms increment. Sets the time that the SOL will wait before the first retry and the time between retries when sending SOL packets to the remote blade. Value range is from 0 to 2550 ms in 10 ms increment. 0 means retries will be sent back-to-back. | ||||
| SsolExitToCliKeySeq | 1.3.6.1.4.1.2.3.51.2.4.10.1.7 | OCTET STRING (SIZE (0..16)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..16)) · read-write · mandatory This is the keystroke sequence used to escape out of SOL session and back to CLI
console. This sequence must have at least one character. The caret symbol (^)
has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that
map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage
return). All occurrences of ^ will be interpreted as part of a Ctrl sequence.
Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences.
The default value for this field is '^[(' i.e. ESC followed by (. | ||||
| SsolResetBladeKeySeq | 1.3.6.1.4.1.2.3.51.2.4.10.1.8 | OCTET STRING (SIZE (0..16)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..16)) · read-write · mandatory This is the keystroke sequence used to reset the blade while in SOL session console. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All occurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[R^[r^[R' i.e. ESC R ESC r ESC R. | ||||
| NsolBladeConfig | 1.3.6.1.4.1.2.3.51.2.4.10.2 | |||
| TsolBladeTable | 1.3.6.1.4.1.2.3.51.2.4.10.2.1 | NA | mandatory | |
table · not-accessible · mandatory SOL Blade configuration table. | ||||
| RsolBladeEntry | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1 | NA | mandatory | |
| CsolBladeIndex | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory SOL Blade table index. | ||||
| CsolBladeName | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CsolBladeEnable | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Disable or enable a SOL on a blade.
| ||||
| CsolBladeIpAddr | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.4 | IpAddress | RO | mandatory |
column · IpAddress · read-only · mandatory IP address of the blade derived from the IP address range for the blade system management processors on the blades. NOTE: The IPv6 address for a blade can be view with the bladeIPv6AddressTable. | ||||
| CsolBladeSessionStatus | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Status of a blade SOL session: solSessionNotReady: no SOL session connected to the blade. solSessionReady: there is an SOL session to the blade. solSessionActive: there is an SOL session to the blade and there is a client using the SOL session.
| ||||
| CsolBladeCapability | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.6 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Display whether or not the blade support SOL feature.
| ||||
| NchassisInternalNetwork | 1.3.6.1.4.1.2.3.51.2.4.11 | |||
| ScinsSupported | 1.3.6.1.4.1.2.3.51.2.4.11.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Number of Chassis Internal Network (CIN) definitions supported. Currently a maximum of 14 CIN definitions can be supported. | ||||
| ScinGlobalEnable | 1.3.6.1.4.1.2.3.51.2.4.11.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable Chassis Internal Network (CIN) function dynamically.
Enabled:
AMM reads the CIN entries. For each enabled entry,
- If the CIN VLAN ID is new and does not have a CIN interface
created yet then create a new CIN interface based on that
CIN VLAN ID. Use the CIN IP address from the entry to create
a host route.
- If the CIN IP address is 0.0.0.0 then start ARP monitoring.
Disabled:
- Stop all ARP monitoring.
- Delete all host routes.
- Delete all CIN interfaces.
| ||||
| TcinTable | 1.3.6.1.4.1.2.3.51.2.4.11.3 | NA | mandatory | |
table · not-accessible · mandatory Chassis Internal Network (CIN) configuration table. | ||||
| RcinEntry | 1.3.6.1.4.1.2.3.51.2.4.11.3.1 | NA | mandatory | |
| CcinIndex | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Chassis Internal Network (CIN) table index. | ||||
| CcinDefExists | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if a Chassis Internal Network (CIN) definition exists for this index or not.
| ||||
| CcinDelete | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Delete Chassis Internal Network (CIN) definition. Works like CIN entry disabled. However, the entry is also deleted. NOTE: Value returned for the GET command is meaningless for this MIB object. Deleting a non-defined entry does nothing.
| ||||
| CcinEnable | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Disable or enable a Chassis Internal Network (CIN) definition.
Enabled:
AMM reads the entry and creates a new CIN interface if the CIN VLAN
ID is new and does not have a CIN interface created yet, adds host
route, and monitors communication path. Start ARP monitoring if
IP is 0.0.0.0.
Disabled:
Delete host route. If this is the last IP address that uses the CIN
interface,
- Stop ARP monitoring if IP is 0.0.0.0.
- Delete the CIN interface if there is no other entry depends on it.
| ||||
| CcinId | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.5 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory This is the Chassis Internal Network (CIN) Virtual LAN (VLAN) ID for
the internal management network between the Management Module,
I/O Module, and the blade OS. The range of valid CIN VLAN IDs is
3 to 4094 (inclusive). This value cannot be the same as the
Serial Over LAN (SOL) or Concurrent KVM (cKVM) VLAN ID.
NOTE: If creating a new CIN definition, you must define cinId
before you define cinIpAddress.
NOTE: Before changing this value on an existing CIN definition,
you must first disable the definition. | ||||
| CcinIpAddress | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.6 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory Chassis Internal Network (CIN) IP address.
Restrictions:
- CIN entries cannot have matching IP addresses, with the exception of 0.0.0.0.
- Multiple IP addresses of 0.0.0.0 with different VLAN IDs are allowed.
- The IP address cannot be multi-cast.
- The IP address cannot match the AMM IP address.
- If the CIN IP address is 0.0.0.0, the blade IP address for CIN which is configured
in the blade's OS can not be in the same subnet as that of AMM.
NOTE: If creating a new CIN definition, you must define cinId
before you define cinIpAddress.
NOTE: Before changing this value on an existing CIN definition,
you must first disable the definition.
NOTE: When ipv6 is enable on one interface, this column will
display all zero IPv4 address | ||||
| CcinIpv6Address | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.7 | InetAddressIPv6 | RW | mandatory |
column · InetAddressIPv6 · read-write · mandatory Chassis Internal Network (CIN) IPv6 address NOTE: When ipv4 is enable on one interface,this column will display all zero IPv6 address. | ||||
| NcinStatus | 1.3.6.1.4.1.2.3.51.2.4.11.4 | |||
| TcinStatusTable | 1.3.6.1.4.1.2.3.51.2.4.11.4.1 | NA | mandatory | |
table · not-accessible · mandatory Table of Chassis Internal Network (CIN) status entry information. | ||||
| RcinStatusEntry | 1.3.6.1.4.1.2.3.51.2.4.11.4.1.1 | NA | mandatory | |
row · not-accessible · mandatory Chassis Internal Network (CIN) status table entry.
| ||||
| CcinStatusIndex | 1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The Chassis Internal Network (CIN) status log index number. For consistent results, view as a table and not as individual entries. | ||||
| CcinStatusString | 1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Status of a Chassis Internal Network (CIN) connection. For example:
Index:1 VLANID:4094 IPADDR:192.168.70.100 MAC:01:0A:0B:00:01:01 Type:Learned Status:Operational
Index is the status entry number in the status table. Followed by the
VLAN ID, IP address, and MAC address that the Management Module is
communicating with on the CIN connection.
Type is either 'Configured' or 'Learned'. Learned implies that the
Management Module dynamically discovered the IP address.
Configured means that the address was explicitly configured in
the Management Module.
Status can be 'Operational', 'Not Operational', or 'Disabled'.
'Operational' means the Management Module can ping the CIN IP address.
'Not Operational' means that the Management Module cannot ping the CIN
IP address. Verify that the blade and I/O Module are configured properly
and that their configurations are compatible with the Management Module.
The blade OS also needs to have an IP host route defined
(e.g. route add -host 192.168.70.100 eth0.4094).
I/O Modules need to have a VLAN defined containing the blade's and the
AMM's port. Blade and I/O Modules need to be powered up and operational.
'Disabled' means that the CIN configuration has been disabled by a
Management Module administrator.
For consistent results, view as a table and not as individual entries. | ||||
| TcinPortConfigTable | 1.3.6.1.4.1.2.3.51.2.4.11.5 | NA | mandatory | |
table · not-accessible · mandatory Chassis Internal Network (CIN) configuration table for viewing and configuring the protocol port information for a particular CIN entry. | ||||
| RcinPortConfigEntry | 1.3.6.1.4.1.2.3.51.2.4.11.5.1 | NA | mandatory | |
row · not-accessible · mandatory Chassis Internal Network (CIN) entry for viewing and configuring the protocol port information for a particular CIN entry. | ||||
| CcinPortConfigCINIndex | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The identifier for the particular CIN configuration that these protocol port definitions are associated with. This object is the same as the cinIndex value in the cinTable. | ||||
| CcinPortConfigIndex | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The identifier of a particular CIN protocol port configuration for a given CIN configuration as specified by cinPortConfigCINIndex. There can be up to 16 unique protocol port definitions per CIN configuration. | ||||
| CcinPortConfigProtocolID | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Indicates whether the port protocol definition is for a TCP or UDP port. If the value of notDefined(3) is returned, the entry has yet to be configured.
| ||||
| CcinPortConfigExternalPort | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The external port number specified for this port protocol definition, ranging from 1 to 65,534. | ||||
| CcinPortConfigInternalPort | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.5 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The internal port number specified for this port protocol definition, ranging from 1 to 65,534. | ||||
| CcinPortConfigEnable | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The status of this port protocol definition.
| ||||
| CcinPortConfigDirection | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The traffic direction specified for this port protocol definition.
| ||||
| NconfigurationManagement | 1.3.6.1.4.1.2.3.51.2.4.15 | |||
| SsaveConfigurationToChassis | 1.3.6.1.4.1.2.3.51.2.4.15.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Save the configuration settings from the AMM to the chassis. This operation may take several seconds. The input values for the SET command when AMM is installed in BladeCenter and BladeCenter T are: 1: Save the configuration settings in compressed(AMM) format. 2: Save the configuration settings in legacy(MM) format. This option has been deprecated. other: Invalid. The input values for the SET command when AMM is installed in BladeCenter H and BladeCenter HT are: 1: Save the configuration settings in compressed(AMM) format. other: Invalid. NOTE: This MIB object is for AMM only and the value returned for the GET command is meaningless.
| ||||
| SrestoreConfigurationFromChassis | 1.3.6.1.4.1.2.3.51.2.4.15.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Restore the configuration settings to the AMM from the BladeCenter chassis. NOTE: This MIB object is for AMM only and the value returned for the GET command is meaningless.
| ||||
| SautoReadConfigInNewChassis | 1.3.6.1.4.1.2.3.51.2.4.15.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The AMM will automatically read configuration settings from the midplane every time the AMM is inserted into a new chassis. NOTE: This MIB object is for AMM only.
| ||||
| NtelcoManagement | 1.3.6.1.4.1.2.3.51.2.5 | |||
| NtelcoAlarmReq | 1.3.6.1.4.1.2.3.51.2.5.1 | |||
| StelcoAlarmSet | 1.3.6.1.4.1.2.3.51.2.5.1.1 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Create a software alarm. An input octet string consists of the
alarm severity level and the alarm description (40 bytes max).
The following severity levels are valid :
CRT Critical
MJR Major
MNR Minor
NOTE 1: The level (e.g. MJR) and alarm description string must
be separated by a blank, otherwise, a badValue error will be returned.
NOTE 2: Value returned for the GET command is meaningless for
this MIB object.
NOTE 3: This MIB object is for BladeCenter T only. | ||||
| StelcoAlarmAck | 1.3.6.1.4.1.2.3.51.2.5.1.2 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Acknowledge an alarm. An input octet string consists of the
alarm key ID expressed as 'mmm:ggg:iii:aaa:sss' where:
m : Module ID value of decimal digits(1-255) or
blank space(s) for leading zero(s)
g : Gen ID value of decimal digits(1-255) or
blank space(s) for leading zero(s)
i : GenInfo ID value of decimal digits(1-255) or
blank space(s) for leading zero(s)
a : Alarm ID value of decimal digits(1-255) or
blank space(s) for leading zero(s)
s : Alarm severity value of decimal digits(1-255) or
blank space(s) for leading zero(s)
NOTE 1: Value returned for the GET command is meaningless for
this MIB object.
NOTE 2: This MIB object is for BladeCenter T only. | ||||
| StelcoAlarmClear | 1.3.6.1.4.1.2.3.51.2.5.1.3 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Clear an active alarm. An input octet string consists of the
alarm key ID expressed as 'mmm:ggg:iii:aaa:sss' where:
m : Module ID value of decimal digits(1-255) or
blank space(s) for leading zero(s)
g : Gen ID value of decimal digits(1-255) or
blank space(s) for leading zero(s)
i : GenInfo ID value of decimal digits(1-255) or
blank space(s) for leading zero(s)
a : Alarm ID value of decimal digits(1-255) or
blank space(s) for leading zero(s)
s : Alarm severity value of decimal digits(1-255) or
blank space(s) for leading zero(s)
NOTE1 : Value returned for the GET command is meaningless for
this MIB object.
NOTE 2: This MIB object is for BladeCenter T only. | ||||
| NtelcoHWManagement | 1.3.6.1.4.1.2.3.51.2.5.3 | |||
| NtappowerReq | 1.3.6.1.4.1.2.3.51.2.5.3.1 | |||
| Stappoweronoff | 1.3.6.1.4.1.2.3.51.2.5.3.1.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Telco Alarm Panel power on or power off. If powering off a currently powered on Telco Alarm Panel, then all LEDs of this request card will be reset to OFF and the Safely Remove LED will be turned ON to indicate the card is safe for removal. NOTE: This MIB object is for BladeCenter HT only. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NncReq | 1.3.6.1.4.1.2.3.51.2.5.3.2 | |||
| TncReqTable | 1.3.6.1.4.1.2.3.51.2.5.3.2.1 | NA | deprecated | |
table · not-accessible · deprecated Table of the Network Clock Module Operations. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| RncReqEntry | 1.3.6.1.4.1.2.3.51.2.5.3.2.1.1 | NA | deprecated | |
row · not-accessible · deprecated Network Clock Module Power ON/OFF entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CncReqIndex | 1.3.6.1.4.1.2.3.51.2.5.3.2.1.1.1 | INTEGER (0..128) | RO | deprecated |
column · INTEGER (0..128) · read-only · deprecated Network Clock Module Request index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | ||||
| CncReqBayNumber | 1.3.6.1.4.1.2.3.51.2.5.3.2.1.1.2 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Network Clock Module Request Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
| ||||
| CncReqPoweronoff | 1.3.6.1.4.1.2.3.51.2.5.3.2.1.1.3 | INTEGER | RW | deprecated |
column · INTEGER · read-write · deprecated Request to power on/off for the specified Network Clock Module. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NtelcoOEM | 1.3.6.1.4.1.2.3.51.2.5.127 | |||
| StelcoOEMs | 1.3.6.1.4.1.2.3.51.2.5.127.1 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory A bitmap of information about the contents of this subtree. The bitmap is a variable length string containing a list of 1's and 0's. Every bit that is set to 1 has a corresponding subtree entry that is supported in firmware, while a 0 means that the subtree entry is unavailable. NOTE: This MIB object is for BladeCenter T only. | ||||
| NrestartReset | 1.3.6.1.4.1.2.3.51.2.7 | |||
| SrestartSPImmediately | 1.3.6.1.4.1.2.3.51.2.7.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Restart the MM immediately. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SrestartStandbyMM | 1.3.6.1.4.1.2.3.51.2.7.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Restarts the Standby MM from the Primary MM. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a standby MM.
| ||||
| SswitchOverRedundantMM | 1.3.6.1.4.1.2.3.51.2.7.7 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Switch over to the redundant Management Module. The failover will not occur if the standby or primary MM is in flashing mode. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a redundant MM.
| ||||
| SresetSPConfigAndRestart | 1.3.6.1.4.1.2.3.51.2.7.20 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SresetSPConfigAndRestartSaveLogs | 1.3.6.1.4.1.2.3.51.2.7.21 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. The logs will be saved. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| Nblades | 1.3.6.1.4.1.2.3.51.2.22 | |||
| NprocessorBlade | 1.3.6.1.4.1.2.3.51.2.22.1 | |||
| SbladeMediaTrayBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Allocate the media tray to a blade of a BladeCenter system. On a get command, a blade ID of 0x00 means that no blade is currently using the device. A set command cannot allocate the media tray to the management module. NOTE: A blade cannot be allocated to the media tray if the value of OID remoteMediaTraySwitchEnable of the blade is disabled.
| ||||
| SbladeKVMBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Allocate the keyboard, video, and mouse ports (KVM) to a blade of a blade runner system. On a get command, a blade ID of 0x00 means that no blade is currently using the devices. A set command cannot allocate the KVM to the management module.
| ||||
| TbladeBootSequenceTable | 1.3.6.1.4.1.2.3.51.2.22.1.3 | NA | mandatory | |
table · not-accessible · mandatory Table of blade boot sequence information. Contains the boot sequence information for each blade. | ||||
| RbladeBootSequenceEntry | 1.3.6.1.4.1.2.3.51.2.22.1.3.1 | NA | mandatory | |
| CbootSequenceIndex | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade boot sequence index. | ||||
| CbootSequenceBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CbootSequenceBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CbootSequenceBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified.
| ||||
| CbootSequenceBladeHealthState | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
| ||||
| CbootSequenceBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CbootSequence1 | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The boot device for this blade boot sequence. Note that some types
of blades don't support floppy disk drive. It is recommended that all
boot sequence 1,2 3, and 4 be configured starting from boot sequence 1.
If there is any duplication of the configured boot sequence and the
current configuration, the two boot sequence will be swapped.
For an example: the current boot sequence is
1=HD0, 2=CD, 3=FD, 4=HD1
If the user wants to configure 1=FD which is a duplication of 3 then the
new boot sequence will be:
1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped)
Not all hard drives are available on all blade configurations.
The 'Iscsi critical' option has a special meaning: the blade tries to
find an iscsi boot device and if it does not it keeps trying forever.
| ||||
| CbootSequence2 | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The boot device for this blade boot sequence. Note that some types
of blades don't support floppy disk drive. It is recommended that all
boot sequence 1,2 3, and 4 be configured starting from boot sequence 1.
If there is any duplication of the configured boot sequence and the
current configuration, the two boot sequence will be swapped.
For an example: the current boot sequence is
1=HD0, 2=CD, 3=FD, 4=HD1
If the user wants to configure 1=FD which is a duplication of 3 then the
new boot sequence will be:
1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped)
Not all hard drives are available on all blade configurations.
The 'Iscsi critical' option has a special meaning: the blade tries to
find an iscsi boot device and if it does not it keeps trying forever.
| ||||
| CbootSequence3 | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The boot device for this blade boot sequence. Note that some types
of blades don't support floppy disk drive. It is recommended that all
boot sequence 1,2 3, and 4 be configured starting from boot sequence 1.
If there is any duplication of the configured boot sequence and the
current configuration, the two boot sequence will be swapped.
For an example: the current boot sequence is
1=HD0, 2=CD, 3=FD, 4=HD1
If the user wants to configure 1=FD which is a duplication of 3 then the
new boot sequence will be:
1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped)
Not all hard drives are available on all blade configurations.
The 'Iscsi critical' option has a special meaning: the blade tries to
find an iscsi boot device and if it does not it keeps trying forever.
| ||||
| CbootSequence4 | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.10 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The boot device for this blade boot sequence. Note that some types
of blades don't support floppy disk drive. It is recommended that all
boot sequence 1,2 3, and 4 be configured starting from boot sequence 1.
If there is any duplication of the configured boot sequence and the
current configuration, the two boot sequence will be swapped.
For an example: the current boot sequence is
1=HD0, 2=CD, 3=FD, 4=HD1
If the user wants to configure 1=FD which is a duplication of 3 then the
new boot sequence will be:
1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped)
Not all hard drives are available on all blade configurations.
The 'Iscsi critical' option has a special meaning: the blade tries to
find an iscsi boot device and if it does not it keeps trying forever.
| ||||
| NbladeRemoteControl | 1.3.6.1.4.1.2.3.51.2.22.1.4 | |||
| TbladeRemoteControlTable | 1.3.6.1.4.1.2.3.51.2.22.1.4.1 | NA | mandatory | |
table · not-accessible · mandatory Table of blade remote power control information. Contains power on/off enablement status for each blade. | ||||
| RbladeRemoteControlEntry | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1 | NA | mandatory | |
| CremoteControlIndex | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade remote power control index. | ||||
| CremoteControlBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CremoteControlBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CremoteControlBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The power state for blade. 0 = off, 1 = on, 3 = standby, 4 = hibernate, 255 = unknown.
| ||||
| CremoteControlBladeHealthState | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
| ||||
| CremoteControlBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CremotePowerControlEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Blade remote power control enablement status.
| ||||
| CremoteMediaTrayControlEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Blade media tray enablement status.
| ||||
| CremoteKVMControlEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Blade KVM enablement status. Note that some types of blades don't support KVM
| ||||
| CremoteWakeOnLanControlEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.10 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Blade Wake On LAN enablement status. If WOL is not supported by the blade, it displays 'notApplicable' and WOL can not be enabled or disabled.
| ||||
| CremoteMediaTraySwitchEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.11 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Blade Remote Media Tray Switch enablement status. If the remote disk feature is disabled, this OID cannot be set.
| ||||
| NbladePolicy | 1.3.6.1.4.1.2.3.51.2.22.1.4.2 | |||
| SbladePolicyPowerControlEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Blade remote power control enablement status policy.
| ||||
| SbladePolicyMediaTrayControlEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Blade media tray enablement status policy.
| ||||
| SbladePolicyKVMControlEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Blade KVM enablement status policy. Note that some types of blades don't support KVM.
| ||||
| SbladePolicyWakeOnLanControlEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Blade Wake On LAN enablement status policy. The notApplicable(255) enumeration is not valid for SET operations. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SbladePolicyMediaTraySwitchEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Blade Remote Media Tray Switch enablement status policy. If the remote disk feature is disabled, this OID cannot be set.
| ||||
| SbladePolicyMultipleRemoteVideoEnable | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.6 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Blade multiple remote video sessions enablement status policy. A maximum users can access the video of the same blade from remote console when set to enabled. If it is disabled, only one user can access the video from remote control.
| ||||
| SbladePolicyAutoPowerOn | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.7 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Blade auto-power on policy.
- restore: all blades will be powered on which were previously on.
- auto: all blades will automatically be powered on when power is applied to the chassis.
- manual: all blades will be left off until manually powered on by the user.
| ||||
| SbladePolicyDisconnectionMode | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.8 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Blade disconnection mode.
- noDisconnection: If the blade is already serving a maximum number of users, the requester can't get connection
- forcedisconnection: If the blade is already serving a maximum number of users, the requester can disconnect any connected user.
- accessRequest: If the blade is already serving an user, this one will get an access request from the requester.
| ||||
| SbladePolicySessionTimeOut | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.9 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Client session time out in minutes. If there is no remote presence activity, after that time, the session will be closed authomatically. | ||||
| SbladePolicyRequestTimeOut | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.10 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Client connection request time out in seconds. In case of single session mode, if the requested user does not respond within this timeout, the user request will be accepted authomatically. | ||||
| SbladePolicyRetryTimeOut | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.11 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Client connection retry time out in seconds. It is possible that the current blade access is negotiated by other 2 clients. If the third comes it will need to wait and retry to connect after a while. | ||||
| SbladePolicySessionLostTimeOut | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.12 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Client session lost in minutes. Amount of time before session closes due to loss of session, and user may regain control. This may happen if for example the client machine loses a network connection. | ||||
| NbladeMonitors | 1.3.6.1.4.1.2.3.51.2.22.1.5 | |||
| TbladeSystemStatusTable | 1.3.6.1.4.1.2.3.51.2.22.1.5.1 | NA | mandatory | |
table · not-accessible · mandatory Table of blade status information. | ||||
| RbladeSystemStatusEntry | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1 | NA | mandatory | |
| CbladeStatusIndex | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade system status index. | ||||
| CbladeId | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CbladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CbladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified.
| ||||
| CbladeHealthState | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
| ||||
| CbladeName | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CbladeRemotePowerEnable | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Remote power state for the blade. 0x01 indicates enabled.
| ||||
| CbladeRemoteMediaTrayEnable | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.8 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Remote Media Tray state for the blade. 0x01 indicates enabled.
| ||||
| CbladeRemoteKVMEnable | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Remote keyboard/video/monitor state for the blade. 0x01 indicates enabled. Note that some types of blades don't support KVM
| ||||
| CbladeConnectionType | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Connection type of the expansion card number one.
| ||||
| CbladeOwnsKVM | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the MM owns the KVM. 0 = false, 1 = true. Note that some types of blades don't support KVM
| ||||
| CbladeOwnsMediaTray | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blade owns the Media Tray. 0 = false, 1 = true.
| ||||
| CbladeRemoteWakeOnLanEnable | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.13 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Remote wake on LAN state for the blade. 0x01 indicates enabled.
| ||||
| CbladeServerExpansion | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.14 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade.
| ||||
| CbladeWidth | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The width of the blade including any supplement blade attached to it | ||||
| CbladeSupportCapacityOnDemand | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.16 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated This shows whether this blade support Capacity On Demand. NOTE: This Mib object is deprecated and no longer supported.
| ||||
| CbladeServerExpansion2 | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.17 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade.
| ||||
| CbladecKVMStatus | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.21 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory This shows whether this blade has a concurrent keyboard, video, and mouse (cKVM) card installed and the status of cKVM on the blade. Not present: A cKVM card is not installed. Not ready: A cKVM card is installed but is not functional. Ready: A cKVM card is installed and is functional, with no cKVM session in progress. Active: A cKVM card is installed and is functional, with a cKVM session currently in progress. Disabled: A cKVM card is not enabled on this blade. Not available: A cKVM card is installed but the status is not available.
| ||||
| CbladeConnectionType2 | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.22 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Connection type of the expansion card number 2.
| ||||
| CbladeConnectionType3 | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.23 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Connection type of the expansion card number 3.
| ||||
| CbladeConnectionType4 | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.24 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Connection type of the expansion card number 4.
| ||||
| CbladeConnectionType5 | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.25 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Connection type of the expansion card number 5.
| ||||
| CbladeHighSpeedConnectionType | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.41 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Connection type of the high speed expansion card number 1.
| ||||
| CbladeIOCompatibility | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.51 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory I/O compatibility status for the blade.
The possible values and their meanings are as follows:
unknown: This indicates a communication error for the blade.
ok: This is the normal (good) case where the blade and the
corresponding I/O modules it is internally wired to have no
compatibility issues.
noIOMs: This means there are no I/O modules in any of the
corresponding I/O module bays this blade is internally wired to.
attention: This indicates that one or more of the corresponding
I/O modules are in communication error.
mismatch: This indicates one of the following cases:
Fabric types are incompatible
An unknown I/O module type
An unknown fabric type on the blade | ||||
| CbladeInventoryReady | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.52 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory When a blade management controller or the AMM is reset, the blade inventory data is refreshed in the AMM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the AMM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication for each blade regarding the status of this information. Notes: For blades that are experiencing a 'communication failure' or 'initialization failure' condition, this object will continue to indicate notReady until the condition is resolved. Therefore, any application that polls this object should also incorporate a timeout period. As of AMM release v5.3, a 10 minute timeout seems to be a minimum suggested polling period.
| ||||
| TbladeHealthSummaryTable | 1.3.6.1.4.1.2.3.51.2.22.1.5.2 | NA | mandatory | |
table · not-accessible · mandatory Table of blade health summary information. Contains information about the overall blade health status. | ||||
| RbladeHealthSummaryEntry | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1 | NA | mandatory | |
| CbladeHealthSummaryIndex | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade health summary index. | ||||
| CbladeHealthSummaryBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CbladeHealthSummarySeverity | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory System health summary severity. | ||||
| CbladeHealthSummaryDescription | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory System health summary description. | ||||
| CbladeHealthSummaryDateTime | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory System health summary date time. | ||||
| TbladeTemperaturesTable | 1.3.6.1.4.1.2.3.51.2.22.1.5.3 | NA | mandatory | |
table · not-accessible · mandatory Table of blade temperatures information. | ||||
| RbladeTemperaturesEntry | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1 | NA | mandatory | |
| CtemperatureIndex | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade temperatures table index. | ||||
| CtemperatureBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CtemperatureBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CtemperatureBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified.
| ||||
| CtemperatureBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CtemperatureCPU1 | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU2 | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU3 | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU4 | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureDASD1 | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade DASD temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensorTempCapability | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade is IPMI capable or not.
| ||||
| CbladeSensor1Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor2Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor3Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor4Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor5Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor6Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.17 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor7Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.18 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor8Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.19 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor9Temp | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.20 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| TbladeTemperatureThresholdsTable | 1.3.6.1.4.1.2.3.51.2.22.1.5.4 | NA | mandatory | |
table · not-accessible · mandatory Table of blade temperature thresholds information. | ||||
| RbladeTemperatureThresholdsEntry | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1 | NA | mandatory | |
row · not-accessible · mandatory Blade temperature thresholds table entry | ||||
| CtemperatureThresholdIndex | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade temperature threshold table index. | ||||
| CtemperatureThresholdBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CtemperatureThresholdBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CtemperatureThresholdBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified.
| ||||
| CtemperatureThresholdBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CtemperatureCPU1HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU hard shutdown temperature in degrees
centigrade(C). If the component's temperature rises above
this value the system will be powered off immediately.
If enabled, a critical alert/event will be generated.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU1Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU warning temperature in degrees centigrade(C).
If the temperature rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU1WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU warning reset temperature in degrees
centigrade(C). If the temperature rises above this value and
if a warning alert/event had previously been created then the
alert/event will be reset.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU2HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU hard shutdown temperature in degrees
centigrade(C). If the component's temperature rises above
this value the system will be powered off immediately.
If enabled, a critical alert/event will be generated.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU2Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU warning temperature in degrees centigrade(C).
If the temperature rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU2WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU warning reset temperature in degrees
centigrade(C). If the temperature rises above this value and
if a warning alert/event had previously been created then the
alert/event will be reset.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU3HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU hard shutdown temperature in degrees
centigrade(C). If the component's temperature rises above
this value the system will be powered off immediately.
If enabled, a critical alert/event will be generated.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU3Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU warning temperature in degrees centigrade(C).
If the temperature rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU3WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU warning reset temperature in degrees
centigrade(C). If the temperature rises above this value and
if a warning alert/event had previously been created then the
alert/event will be reset.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU4HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU hard shutdown temperature in degrees
centigrade(C). If the component's temperature rises above
this value the system will be powered off immediately.
If enabled, a critical alert/event will be generated.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU4Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU warning temperature in degrees centigrade(C).
If the temperature rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureCPU4WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.17 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade CPU warning reset temperature in degrees
centigrade(C). If the temperature rises above this value and
if a warning alert/event had previously been created then the
alert/event will be reset.
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureDASD1HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.18 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade DASD hard shutdown temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureDASD1Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.19 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade DASD warning temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureDASD1WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.20 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade DASD warning reset temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeTempThresholdSensorCapability | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.21 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade is IPMI capable or not.
| ||||
| CtemperatureSensor1HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.22 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor1Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.23 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor1WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.24 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor2HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.25 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor2Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.26 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor2WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.27 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor3HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.28 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor3Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.29 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor3WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.30 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor4HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.31 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor4Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.32 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor4WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.33 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor5HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.34 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor5Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.35 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor5WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.36 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor6HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.37 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor6Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.38 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor6WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.39 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor7HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.40 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor7Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.41 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor7WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.42 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor8HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.43 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor8Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.44 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor8WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.45 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor9HardShutdown | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.46 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor9Warning | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.47 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CtemperatureSensor9WarningReset | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.48 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| TbladeVoltagesTable | 1.3.6.1.4.1.2.3.51.2.22.1.5.5 | NA | mandatory | |
table · not-accessible · mandatory Table of blade voltages information. | ||||
| RbladeVoltagesEntry | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1 | NA | mandatory | |
| CvoltageIndex | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade voltages table index. | ||||
| CvoltageBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CvoltageBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CvoltageBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified.
| ||||
| CvoltageBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CbladePlus5Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory +5 Volt power supply voltage reading for the blade
expressed in Volts(V). An octet string expressed as
'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus3pt3Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory +3.3 Volt power supply voltage reading for the blade
expressed in Volts(V). An octet string expressed as
'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus12Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory +12 Volt power supply voltage reading for the blade
expressed in Volts(V). An octet string expressed as
'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus2pt5Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory +2.5 Volt power supply voltage reading for the blade
expressed in Volts(V). An octet string expressed as
'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus1pt5Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory +1.5 Volt power supply voltage reading for the blade
expressed in Volts(V). An octet string expressed as
'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus1pt25Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory +1.25 Volt power supply voltage reading for the blade
expressed in Volts(V). An octet string expressed as
'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeVRM1Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory VRM 1 voltage reading for the blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensorVoltCapability | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.14 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade is IPMI capable or not.
| ||||
| CbladeSensor1Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor2Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor3Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.17 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor4Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.18 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor5Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.19 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor6Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.20 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor7Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.21 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor8Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.22 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor9Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.23 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor10Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.24 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor11Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.25 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor12Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.26 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor13Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.27 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor14Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.28 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor15Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.29 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor16Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.30 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor17Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.31 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor18Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.32 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor19Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.33 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor20Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.34 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor21Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.35 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor22Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.36 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor23Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.37 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor24Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.38 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor25Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.39 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor26Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.40 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor27Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.41 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor28Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.42 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor29Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.43 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor30Volt | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.44 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage reading for an IPMI blade expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| TbladeVoltageThresholdsTable | 1.3.6.1.4.1.2.3.51.2.22.1.5.6 | NA | mandatory | |
table · not-accessible · mandatory Table of blade VoltageThresholds information. | ||||
| RbladeVoltageThresholdsEntry | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1 | NA | mandatory | |
| CvoltageThresholdIndex | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade voltage thresholds table index. | ||||
| CvoltageThresholdBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CvoltageThresholdBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CvoltageThresholdBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified.
| ||||
| CvoltageThresholdBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory The name of the blade as a null terminated string. | ||||
| CbladePlus5VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading expressed in Volts(V).
If the voltage rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus5VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading expressed in Volts(V).
If the voltage drops below this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus3pt3VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading expressed in Volts(V).
If the voltage rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus3pt3VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading expressed in Volts(V).
If the voltage drops below this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus12VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading expressed in Volts(V).
If the voltage rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus12VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading expressed in Volts(V).
If the voltage drops below this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus2pt5VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading expressed in Volts(V).
If the voltage rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus2pt5VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading expressed in Volts(V).
If the voltage drops below this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus1pt5VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading expressed in Volts(V).
If the voltage rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus1pt5VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.17 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading expressed in Volts(V).
If the voltage drops below this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus1pt25VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.18 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading expressed in Volts(V).
If the voltage rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladePlus1pt25VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.19 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading expressed in Volts(V).
If the voltage drops below this value a warning alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeVoltThresholdSensorCapability | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.22 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade is IPMI capable or not.
| ||||
| CbladeSensor1VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.23 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor1VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.24 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor2VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.25 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor2VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.26 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor3VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.27 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor3VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.28 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor4VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.29 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor4VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.30 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor5VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.31 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor5VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.32 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor6VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.33 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor6VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.34 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor7VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.35 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor7VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.36 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor8VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.37 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor8VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.38 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor9VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.39 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor9VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.40 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor10VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.41 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor10VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.42 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor11VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.43 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor11VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.44 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor12VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.45 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor12VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.46 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor13VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.47 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor13VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.48 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor14VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.49 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor14VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.50 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor15VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.51 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor15VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.52 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor16VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.53 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor16VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.54 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor17VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.55 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor17VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.56 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor18VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.57 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor18VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.58 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor19VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.59 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor19VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.60 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor20VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.61 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor20VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.62 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor21VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.63 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor21VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.64 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor22VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.65 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor22VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.66 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor23VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.67 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor23VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.68 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor24VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.69 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor24VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.70 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor25VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.71 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor25VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.72 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor26VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.73 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor26VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.74 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor27VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.75 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor27VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.76 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor28VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.77 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor28VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.78 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor29VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.79 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor29VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.80 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor30VoltHighWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.81 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage rises above this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| CbladeSensor30VoltLowWarning | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.82 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Voltage warning threshold reading for IPMI blades expressed in Volts(V).
If the voltage drops below this value, a critical alert/event
if enabled will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Voltage' indicates that the given monitor
does not exist on this system or is powered off. | ||||
| TbladeIOCompatibilityTable | 1.3.6.1.4.1.2.3.51.2.22.1.5.7 | NA | mandatory | |
table · not-accessible · mandatory Table of IO Compatibility status for the blade. | ||||
| RbladeIOCompatibilityEntry | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1 | NA | mandatory | |
| CbladeIOCompatibilityIndex | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The blade I/O compatibility table index. | ||||
| CbladeIOCompatibilityBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The blade numeric identifier.
| ||||
| CbladeIOCompatibilityBayNumber | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The Bay number of the blade or expension card. | ||||
| CbladeIOCompatibilityModuleBay | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The modules (each one specified by module type and bay number) that the blade can communicate with over the midplane networking fabric (i.e. a physical path exists between the blade and this module, and hardware exists on the blade to communicate with this module). | ||||
| CbladeIOCompatibilityModulePower | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The power state of the module specified in bladeIOCompatibilityModuleBay. n/a if module not installed. | ||||
| CbladeIOCompatibilityModuleFabricType | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The fabric type of the module specified in bladeIOCompatibilityModuleBay. | ||||
| CbladeIOCompatibilityFabricOnBlade | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The fabric type for this channel on the blade (may be onboard fabric or an expansion card). | ||||
| CbladeIOCompatibilityStatus | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The compatibility status between the blade and the module specified
in bladeIOCompatibilityModuleBay.
The possible values are:
OK: No compatibility issues
No IOM: There is no module on the other side of the wire for this channel on the blade.
n/a: (Not applicable) The module specified in bladeIOCompatibilityModuleBay is a bridge,
so the blade port cannot connect to it.
Attention: The module specified in bladeIOCompatibilityModuleBay has a communication error.
Mismatch: Indicates one of the following cases:
Fabric types are incompatible
Module specified in bladeIOCompatibilityModuleBay is of unknown type
Unknown fabric type on the blade | ||||
| NbladePowerRestart | 1.3.6.1.4.1.2.3.51.2.22.1.6 | |||
| TbladePowerRestartTable | 1.3.6.1.4.1.2.3.51.2.22.1.6.1 | NA | mandatory | |
table · not-accessible · mandatory Table of blade remote power control information. Contains power on/off enablement status for each blade. | ||||
| RbladePowerRestartEntry | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1 | NA | mandatory | |
| CpowerRestartIndex | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade power restart table index. | ||||
| CpowerRestartBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CpowerRestartBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CpowerRestartBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified. If the state cannot be determined, the unknown(255) value is returned.
| ||||
| CpowerRestartBladeHealthState | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
| ||||
| CpowerRestartBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CpowerOnOffBlade | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Control the power state of a specific blade.
Off: Power Off Blade.
On: Power On Blade.
Softoff: Shut Down OS and Power Off Blade. This operation is not
supported on all blades.
NOTE: Value returned for the GET command is meaningless
for this MIB object. The powerRestartBladePowerState MIB object should be
used to check the power state of the blade(s)
| ||||
| CrestartBlade | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Restart a blade. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CrestartBladeSMP | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Restart a blade's system management processor. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CrestartBladeNMI | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.10 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Issue an NMI to the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CrestartBladeClearNVRAM | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.11 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Restart a blade and set NVRAM to default values. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CrestartBladeInvokeDiags | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.12 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Restart a blade and boot into diagnostic mode. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CrestartBladeInvokeDiagsFromDefaultBootList | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.13 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Restart a blade and boot into diagnostic mode from Default Boot List as defined on the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CrestartBladeToSMSBootMenu | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.14 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Restart a blade to SMS boot menu. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CrestartBladeToUEFIMenu | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.15 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Restart a blade to UEFI setup menu. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NbladeConfiguration | 1.3.6.1.4.1.2.3.51.2.22.1.7 | |||
| TbladeConfigurationTable | 1.3.6.1.4.1.2.3.51.2.22.1.7.1 | NA | mandatory | |
table · not-accessible · mandatory Table of blade remote power control information. Contains power on/off enablement status for each blade. | ||||
| RbladeConfigurationEntry | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1 | NA | mandatory | |
| CconfigurationIndex | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade configuration table index. | ||||
| CconfigurationBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CconfigurationBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CconfigurationBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified.
| ||||
| CconfigurationBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory The name of the blade as a null terminated string. | ||||
| CconfigurationBladecKVM | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enable or disable the concurrent KVM function on specified blade. If concurrent KVM is not supported by the blade, it displays 'notPresent' and the concurrent KVM functionality can not be enabled or disabled.
| ||||
| CconfigurationBladeActiveBootMode | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the active copy of the firmware from which the blade is booting. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible.
| ||||
| CconfigurationBladePendingBootMode | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Indicates the copy of the firmware from which the blade will boot after the next reboot. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades and the value can not be set. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible.
| ||||
| NbladePowerManagementPolicy | 1.3.6.1.4.1.2.3.51.2.22.1.7.2 | |||
| Spowerdomain1Oversubscription | 1.3.6.1.4.1.2.3.51.2.22.1.7.2.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Power Management Policy settings for power domain 1.
| ||||
| Spowerdomain2Oversubscription | 1.3.6.1.4.1.2.3.51.2.22.1.7.2.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Power Management Policy settings for power domain 2.
| ||||
| SacousticMode | 1.3.6.1.4.1.2.3.51.2.22.1.7.2.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Acoustic mode setting for thermal conditions
| ||||
| SnebsMode | 1.3.6.1.4.1.2.3.51.2.22.1.7.2.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory NEBS (Network Equipment-Building System) mode setting for thermal conditions. NOTE: This MIB object is for BladeCenter T, HT and TR only.
| ||||
| SbladecKVMEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.1.7.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Enable or disable cKVM function on all server blades.
| ||||
| SbladeIPAddrRangeStart | 1.3.6.1.4.1.2.3.51.2.22.1.8 | IpAddress | RO | deprecated |
scalar · IpAddress · read-only · deprecated This field is used to configure the start of the IP address range for the blade system management processors on the blades. These addresses are used on the internal management network between the MM and the blade BSMPs. For example the value of 10.10.10.1 means the BSMP on the blade in bay 1 will have IP address 10.10.10.1, the BSMP on the blade in bay 2 will have IP address 10.10.10.2 and so on. This field is deprecated and no longer supported. An attempt to SET this object will be rejected, and any query will always return 0.0.0.0. Refer to the bladeManagementNetworkInfoTable for the new objects providing this information. | ||||
| NbladeCapacityOnDemand | 1.3.6.1.4.1.2.3.51.2.22.1.9 | |||
| TbladeCapacityOnDemandTable | 1.3.6.1.4.1.2.3.51.2.22.1.9.1 | NA | deprecated | |
table · not-accessible · deprecated Table of COD blade. NOTE: This table is deprecated and no longer supported. | ||||
| RbladeCapacityOnDemandEntry | 1.3.6.1.4.1.2.3.51.2.22.1.9.1.1 | NA | deprecated | |
row · not-accessible · deprecated Blade COD table entry NOTE: This table is deprecated and no longer supported. | ||||
| CbladeCapacityOnDemandIndex | 1.3.6.1.4.1.2.3.51.2.22.1.9.1.1.1 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Blade configuration table index. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CbladeCapacityOnDemandBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.9.1.1.2 | OCTET STRING | RO | deprecated |
column · OCTET STRING · read-only · deprecated The name of the blade as a null terminated string. NOTE: This Mib object is deprecated and no longer supported. | ||||
| CbladeCapacityOnDemandState | 1.3.6.1.4.1.2.3.51.2.22.1.9.1.1.3 | INTEGER | RW | deprecated |
column · INTEGER · read-write · deprecated The state of Capacity On Demand. NOTE: This Mib object is deprecated and no longer supported.
| ||||
| NbladeBootCountPowerOnTime | 1.3.6.1.4.1.2.3.51.2.22.1.10 | |||
| TbladeBootCountPowerOnTimeTable | 1.3.6.1.4.1.2.3.51.2.22.1.10.1 | NA | mandatory | |
table · not-accessible · mandatory Table per blade of the number of boots for the blade and the number of seconds the blade has been powered on. | ||||
| RbladeBootCountPowerOnTimeEntry | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1 | NA | mandatory | |
row · not-accessible · mandatory The number of boots for the blade and the number of seconds the blade has been powered on. | ||||
| CbootCountPowerOnTimeBladeIndex | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade boot count/Power On Time table index. | ||||
| CbootCountPowerOnTimeBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CbootCountPowerOnTimeBoots | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Blade Boot Count. If there is no blade in the given slot then this value is undefined. Writing this value resets the Boot Count to zero. | ||||
| CbootCountPowerOnTimeSecs | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Blade Power On Time in seconds. If there is no blade in the given slot then this value is undefined. Writing this value resets the Power On Time to zero. | ||||
| SbladeVlanId | 1.3.6.1.4.1.2.3.51.2.22.1.11 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory This is the virtual LAN ID for the internal management network between the MM and the blade system management processors (BSMPs). The range of valid VLAN ID's is 3 to 4095. | ||||
| NbladeNetworkConfiguration | 1.3.6.1.4.1.2.3.51.2.22.1.12 | |||
| TbladeNetworkInterfaceTable | 1.3.6.1.4.1.2.3.51.2.22.1.12.2 | NA | mandatory | |
table · not-accessible · mandatory Table of all blades' network interfaces. | ||||
| RbladeNetworkInterfaceEntry | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1 | NA | mandatory | |
| CbladeNetworkInterfaceIndex | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade Network Interface Table index. | ||||
| CbladeNetworkInterfaceBayNumber | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The bay number of the main server blade that supports network interface management | ||||
| CbladeNetworkInterfaceNumber | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates which network interface on the blade System Management Processor is be read or writen | ||||
| CbladeNetworkInterfaceType | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates blade network interface type.
| ||||
| CbladeNetworkInterfaceLabel | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Show string label that identifies the interface. | ||||
| CbladeNetworkInterfaceIPAddr | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.6 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory Show/modify current IP address of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the IP address be pushed down to blade System Management Processor | ||||
| CbladeNetworkInterfaceSubnetMask | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.7 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory Show or modifie current subnet mask of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the SunnetMask be pushed down to blade System Management Processor | ||||
| CbladeNetworkInterfaceGatewayAddr | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.8 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory Show or modify current IP gateway of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the Gateway address be pushed down to blade System Management Processor | ||||
| CbladeNetworkInterfaceVlanId | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory This is the Virtual LAN ID for supported network interface cards (NICs). The range of valid VLAN ID's is 0 to 4095. | ||||
| CbladeNetworkInterfaceVlanEnable | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.10 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated This object is no longer supported and will always be 0
| ||||
| CbladeNetworkInterfaceEnable | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.11 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Disabled or enabled the blade network interface. If the network interface is disabled, then ignore other configurations. If this network interface doesn't support enabled/disabled, show 'notApplicable(255)'
| ||||
| CbladeNetworkInterfaceDHCPEnable | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.12 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory IP config method on the blade network interface to modify mode to static IP, dhcp and dhcpthenstatic. If this network interface doesn't support DHCP, show 'notApplicable(255)'
| ||||
| CbladeNetworkInterfaceMACAddr | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Show the blade network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable' | ||||
| CbladeNetworkInterfaceAssignedSwitch | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.14 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory This field allows you to select an I/O Module to use for management traffic to the blade. NOTE: This field is only supported for eth1 of blade. NOTE: You may only specify ethernet switches to this field.
| ||||
| NbladeIPv6Config | 1.3.6.1.4.1.2.3.51.2.22.1.12.10 | |||
| TbladeIPv6ConfigTable | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1 | NA | mandatory | |
table · not-accessible · mandatory A table of IPv6 configuration options for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6. | ||||
| RbladeIPv6ConfigEntry | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1 | NA | mandatory | |
row · not-accessible · mandatory IPv6 configuration options for a blade. NOTE: This MIB object is not applicable to blades that do not support IPv6. | ||||
| CbladeIPv6ConfigIndex | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The blade's slot number | ||||
| CbladeIPv6ConfigPortIndex | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The physical port number of the given entry | ||||
| CbladeIPv6ConfigEnabled | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enables/Disables IPv6 support on the blade.
| ||||
| CbladeIPv6ConfigStatic | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enables/Disables IPv6 static configuration support on the blade.
| ||||
| CbladeDHCPv6ConfigEnabled | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.5 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enables/Disables DHCPv6 address configuration support on the blade.
| ||||
| CbladeIPv6ConfigStatelessEnabled | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enables/Disables IPv6 stateless auto-configuration support on the blade.
| ||||
| TbladeIPv6AddressTable | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2 | NA | mandatory | |
table · not-accessible · mandatory A table of assigned IPv6 addresses for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6. | ||||
| RbladeIPv6AddressEntry | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1 | NA | mandatory | |
row · not-accessible · mandatory The assigned IPv6 address for a given blade. NOTE: This MIB object is not applicable to blades that do not support IPv6. | ||||
| CbladeIPv6AddressIndex | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The blade's slot number. | ||||
| CbladeIPv6AddressPortIndex | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The blade's physical port number for the given entry. | ||||
| CbladeIPv6AddressEntryIndex | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The blade's address entry index. | ||||
| CbladeIPv6AddressType | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The address type.
| ||||
| CbladeIPv6Address | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.5 | InetAddressIPv6 | RW | mandatory |
column · InetAddressIPv6 · read-write · mandatory The assigned IPv6 address. Note: 'write' is for static ipv6 only. | ||||
| CbladeIPv6AddressPrefixLen | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.6 | INTEGER (1..128) | RW | mandatory |
column · INTEGER (1..128) · read-write · mandatory The prefix length for the given address. Note: 'write' is for static ipv6 only. | ||||
| CbladeIPv6AddressDefaultRoute | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.7 | InetAddressIPv6 | RW | mandatory |
column · InetAddressIPv6 · read-write · mandatory The default route used for the given address. Note: 'write' is for static ipv6 only. | ||||
| TbladeBayDataTable | 1.3.6.1.4.1.2.3.51.2.22.1.13 | NA | mandatory | |
table · not-accessible · mandatory Table of blade bay data (BBD) information. | ||||
| RbladeBayDataEntry | 1.3.6.1.4.1.2.3.51.2.22.1.13.1 | NA | mandatory | |
| CbayDataIndex | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade bay data (BBD) table index. | ||||
| CbayDataBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CbayDataBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the server blade specified exists or not.
| ||||
| CbayDataBladePowerState | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the power state of the blade specified.
| ||||
| CbayDataBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CbayData | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.6 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory A null terminated string that defines the Blade Bay Data (BBD). This data is pushed to the blade's BSMP and SMBIOS structures, where it can used by the blade's OS. Up to 60 characters can be defined plus a Null terminator. | ||||
| CbayDataBladeStatus | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory This shows Blade Bay Data (BBD) status. 0 means the blade fully supports BBD; 1 means that the blade's BIOS does not support BBD; 2 means that there is no blade in the bay; 3 means that the blade is being discovered. 255 means that the blade does not support BBD.
| ||||
| NbladeSPEthOverUSBInterface | 1.3.6.1.4.1.2.3.51.2.22.1.14 | |||
| TspEthOverUSBInterfaceTable | 1.3.6.1.4.1.2.3.51.2.22.1.14.1 | NA | mandatory | |
table · not-accessible · mandatory Table of blade Service Processor's Ethernet over USB interface. | ||||
| RspEthOverUSBInterfaceEntry | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1 | NA | mandatory | |
row · not-accessible · mandatory Blade Service Processor's Ethernet over USB interface entry. | ||||
| CspEthOverUSBInterfaceIndex | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Service Processor's Ethernet over USB interface table index. | ||||
| CspEthOverUSBInterfaceBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The numeric blade ID. | ||||
| CspEthOverUSBInterfaceBladeExists | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blade specified exists or not.
| ||||
| CspEthOverUSBInterfaceBladeName | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a null terminated string. | ||||
| CspEthOverUSBInterfaceEnable | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory This object allows the user to view the status of, and enable or disable, a blade Service Processor's command interface on Ethernet-over-USB. NOTE: If the blade either does not exist or does not support Ethernet-over-USB command interface. It displays 'notApplicable'. NOTE: It will take about 10 or more seconds for the disable/enable setting to take effect.
| ||||
| NbladeManagementNetwork | 1.3.6.1.4.1.2.3.51.2.22.1.15 | |||
| SbladeManagementNetworkControlEnable | 1.3.6.1.4.1.2.3.51.2.22.1.15.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Globally disable/enable blade management network auto discovery support.
| ||||
| TbladeManagementNetworkInfoTable | 1.3.6.1.4.1.2.3.51.2.22.1.15.2 | NA | mandatory | |
table · not-accessible · mandatory Table of blade management network information. | ||||
| RbladeManagementNetworkInfoEntry | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1 | NA | mandatory | |
row · not-accessible · mandatory Blade management network information entry. | ||||
| CbladeManagementNetworkInfoIndex | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade management network information table index | ||||
| CbladeManagementNetworkInfoBladeId | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The Blade ID.
| ||||
| CbladeManagementNetworkInfoBladeExist | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blade specified exists or not in the chassis. | ||||
| CbladeManagementNetworkInfoBladeSupport | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blade supports the management network auto discovery capability or not. | ||||
| CbladeManagementNetworkInfoPathStatus | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the status of the management network for this blade.
| ||||
| CbladeManagementNetworkInfoBladeIPAddr | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.6 | IpAddress | RO | mandatory |
column · IpAddress · read-only · mandatory Indicates the blade system management processor IPv4 address. | ||||
| CbladeManagementNetworkInfoBladeMACAddr | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates the blade system management processor MAC address. | ||||
| CbladeManagementNetworkInfoSwitchId | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.8 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates which switch is selected for the blade management network. | ||||
| NswitchModule | 1.3.6.1.4.1.2.3.51.2.22.3 | |||
| NswitchModuleControl | 1.3.6.1.4.1.2.3.51.2.22.3.1 | |||
| TsmControlTable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module control table. | ||||
| RsmControlEntry | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1 | NA | mandatory | |
| CsmControlIndex | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module control table index. | ||||
| CswitchModuleControlId | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module numeric identifier.
| ||||
| CsmPostResultsAvailable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Describes whether the switch module POST diagnostic result value contained in the smPostResultsValue is valid.
| ||||
| CsmPostResultsValue | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The range of values and meanings are as follows: 0x00 - 0x7F ( 0 - 127) Base internal functions 0x80 - 0x9F (128 - 159) Internal interface failures 0xA0 - 0xAF (160 - 175) External interface failures 0xB0 - 0xFE (176 - 254) Reserved 0xFF (255) Switch completed POST successfully | ||||
| CswitchModuleMemDiagEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.5 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Switch module memory diagnostics enabled or disabled.
NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional
(i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already
published.
| ||||
| CsmCfgCtrlEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Switch module configuration control. When set to enabled, only the MM can manage
the module.
This MIB object can not be set, if AMM grants switch module the Protected Mode permission.
This MIB object can not be set, if the switch module is participating in the Stacking Mode
and external management is protected.
NOTE: This MIB object is not applicable to modules that are running in Network Address
Translation (NAT) Mode. A value of disabled(0) will be returned.
| ||||
| CsmExtEthPortsEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Switch module external ethernet ports enabled or disabled. This MIB object can not be set, if AMM grants switch module the Protected Mode permission. This MIB object can not be set, if the switch module is participating in the Stacking Mode and External Port Access is protected.
| ||||
| CswitchPingRequest | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.8 | INTEGER | RW | deprecated |
column · INTEGER · read-write · deprecated Sends a ping to a switch module's current IPv4 address. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. This MIB object can not be set, if the switch module is participating in the Stacking Mode and IP Configuration is protected. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This object has been deprecated in favor of the new table smPingTable which supports IPv6 and IPv4 addresses.
| ||||
| CsmCfgCtrlOnResetEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Switch module configuration control on resets (default and unsolicited).
When set to enabled, the factory default IP configuration will become
active when the I/O module is reset to factory defaults by either the
management module or the I/O module. If an I/O module reset is initiated
by a source other than the management module then the previous IP configuration
will be in affect. In both these cases the MM will lose IP communications with
the IOM.
This MIB object can not be set, if AMM grants switch module the Protected Mode
permission and switch module goes into Protected Mode.
NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional
(i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already
published.
NOTE: This MIB object is not applicable to modules that are running in Network Address
Translation (NAT) Mode. A value of disabled(1) will be returned.
| ||||
| CsmHealthState | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The health state for the switch module. 0 = unknown, 1 = good, 2 = warning, 3 = bad.
| ||||
| CsmPMState | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The Protected Mode Status for the switch module. standby- Protected Mode capability exists on the IOM but has not been activated on the switch module or the AMM. pending - Protected Mode has been activated on the AMM but not yet on the switch module. active - Protected Mode is active on both the switch module and the AMM. attention - Protected Mode is enabled on the switch module but not on the AMM.
| ||||
| CsmPMCtrlEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.17 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory AMM Protected Mode permission for the switch module. disabled - allow AMM to disable Protected Mode Permission for the switch module. enabled - allow AMM to grant Protected Mode Permission for the switch module.
| ||||
| CsmIOCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.18 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The compatibility status for the I/O module. The possible values and their meanings are as follows: Unknown: This indicates a communication error for the I/O module. OK: This is the normal (good) case where there are no compatibility issues between the I/O module and the modules it is internally wired to. No Fabric: This means the other end is not populated on any of the modules this I/O module is internally wired to (e.g. this is an Infiniband switch but none of the blades it is internally wired to has an expansion card attached in the corresponding expansion slot). Attention: Indicates one of the following cases: One or more of the modules this I/O module is internally wired to is in communication error The I/O module is powered off and at least one module it is internally wired to is powered on Mismatch: Indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on a module the I/O module is internally wired to. | ||||
| TsmPingTable | 1.3.6.1.4.1.2.3.51.2.22.3.1.2 | NA | mandatory | |
table · not-accessible · mandatory Allows pinging one of the active assigned addresses of an I/O module. NOTE: This table is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | ||||
| RsmPingEntry | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1 | NA | mandatory | |
row · not-accessible · mandatory Represents a single address that can be pinged | ||||
| CsmPingIndex | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module's slot number | ||||
| CsmPingAddressEntryIndex | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module's address entry index | ||||
| CsmPingAddress | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The switch module's IPv4 or IPv6 address | ||||
| CsmPingAddressExecute | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Pings the given IP address. NOTE: The GET operation for this object is meaningless.
| ||||
| TsmPowerRestartTable | 1.3.6.1.4.1.2.3.51.2.22.3.1.7 | NA | mandatory | |
table · not-accessible · mandatory Switch module power restart table. | ||||
| RsmPowerRestartEntry | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1 | NA | mandatory | |
| CsmPowerRestartIndex | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module power restart index. | ||||
| CsmPowerRestartId | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module numeric identifier.
| ||||
| CsmSwitchExists | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module specified exists or not.
| ||||
| CsmSwitchType | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module type.
| ||||
| CsmMACAddress | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module MAC address. | ||||
| CsmIPAddress | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.6 | IpAddress | RO | mandatory |
column · IpAddress · read-only · mandatory The switch module current IP address. If the switch module is participating in the Stacking Mode and IP Configuration is protected, then the stack management IP address is displayed. NOTE: IPv6 addresses for the switch can be view with the smIPv6AddressTable. | ||||
| CswitchModulePowerOnOff | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory I/O Module power on or power off. If powering on a currently powered off I/O Module, then the I/O Module will execute a POST. The results of this POST will need to be retrieved using the 'Post Results' command. NOTE: When powering off a currently powered on I/O Module, a minimum of 1 second is needed to allow the module to power off before powering back on. The value 'shutdownInProgress' is for I/O Modules that may take some time to transition from 'poweron' to 'poweroff'. For example, SAS Controller Modules must flush pending I/O before powering off in order to maintain data integrity. The value'shutdownInProgress' can not be used to set. If both SAS Controller Module and SAS Connectivity Module are installed in slot 3 and 4 of BCS chassis, AMM must prevent one of them from powering on otherwise there would be conflict with the Storage Module access and possibly corruption of data. This MIB object can not be set, if AMM grants the I/O Module the Protected Mode permission and module goes into Protected Mode.
| ||||
| CsmReset | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CsmResetToDefault | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. In both cases, the switch module will reset the configuration to the default values. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. This MIB object can not be set, if the switch module is participating in the Stacking Mode and reset to default is protected. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CsmRestartAndRunStdDiag | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.10 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory To power cycle the selected module(s) and then run the standard diagnostic test package. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CsmRestartAndRunExtDiag | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.11 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory To power cycle the selected module(s) and then run the extended diagnostic test package. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CsmRestartAndRunFullDiag | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory To power cycle the selected module(s) and then run the full diagnostic test package. The full diagnostic test package may take over 5 minutes to run. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CsmSwitchSubType | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.20 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module subtype. NOTE: Some Legacy modules do not support a subtype and will be displayed as unknown.
| ||||
| CsmSwitchWidth | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.21 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module width. | ||||
| CsmManufacturingID | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.22 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch module hardware VPD manufacturing ID. | ||||
| CsmStackingModeState | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.23 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The Stacking Mode Status for the switch module. standby - I/O module has stacking capability but is not part of a stack. member - I/O module has stacking capability and is part of a stack in the member role. master - I/O module has stacking capability and is part of a stack in the master role. NOTE: The term disabled was changed to the term standby to be more descriptive.
| ||||
| CsmStackingModeInfo | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.24 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A string containing a text description about the details of which functions are protected for a switch module when it is in Stacking Mode as Master or Member. The possible functions protected by switch modules are IP configuration, External Port Access, External Management all over ports and Restore to defaults. | ||||
| TsmIOCompatibilityTable | 1.3.6.1.4.1.2.3.51.2.22.3.1.10 | NA | mandatory | |
table · not-accessible · mandatory Switch module control table. | ||||
| RsmIOCompatibilityEntry | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module IO compatibility table entry | ||||
| CsmIOCompatibilityIndex | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module IO compatibility index. | ||||
| CsmIOCompatibilityId | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module numeric identifier.
| ||||
| CsmIOCompatibilityModuleBay | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The modules (each one specified by module type and bay number) that this I/O module can communicate with over the midplane networking fabric (i.e. a physical path exists between the I/O module and this module). | ||||
| CsmIOCompatibilityModulePower | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The power state of the module specified in smIOCompatibilityModuleBay. | ||||
| CsmIOCompatibilityModuleFabricType | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The I/O fabric type on the module side for the module. 'n/a' will be displayed if the corresponding channel is not populated on the module side (e.g. we are looking at the details for an Infiniband switch but the blade does not have an Infiniband expansion card attached in the corresponding expansion slot). | ||||
| CsmIOCompatibilityStatus | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The compatibility status for this I/O module and the module specified
in smIOCompatibilityModuleBay.
The possible values are:
OK: No compatibility issues
n/a: Indicates the corresponding channel is not populated on the module
side even though the module is present (e.g. we are looking at the details
for an Infiniband switch but the blade specified in smIOCompatibilityModuleBay
does not have an Infiniband expansion card attached in the corresponding expansion slot).
Attention: Indicates one of the following:
The module specified in smIOCompatibilityModuleBay has a communication error.
The I/O module is powered off but the module specified in smIOCompatibilityModuleBay is powered on.
Mismatch: Indicates one of the following cases::
Fabric types are incompatible
Unknown fabric type on the module side
Unknown I/O module type | ||||
| NswitchModuleConfig | 1.3.6.1.4.1.2.3.51.2.22.3.2 | |||
| NswitchMgmtNetworkCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.1 | |||
| NswitchCurrentNwCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1 | |||
| TsmCurrentIPInfoTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module current IP information. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | ||||
| RsmCurrentIPInfoEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module current IP table entry. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
| ||||
| CsmCurrentIPInfoIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module current IP info index. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | ||||
| CsmCurrentIPInfoId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
| ||||
| CsmCurrentIPInfoExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
| ||||
| CsmCurrentIPInfoPowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the I/O Module specified is powered on or not. The value 'shutdownInProgress' is for the I/O Module that may take some time to transition from 'poweron' to 'poweroff'. Such as SAS Controller Modules, that must flush pending I/O before powering off in order to maintain data integrity. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
| ||||
| CsmCurrentIPAddr | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.6 | IpAddress | RO | mandatory |
column · IpAddress · read-only · mandatory The switch module current IP address. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | ||||
| CsmCurrentSubnetMask | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.7 | IpAddress | RO | mandatory |
column · IpAddress · read-only · mandatory The switch module current subnet mask. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | ||||
| CsmCurrentGateway | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.8 | IpAddress | RO | mandatory |
column · IpAddress · read-only · mandatory The switch module current IP gateway. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | ||||
| CsmCurrentIPConfigMethod | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module current IP configuration method. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
| ||||
| NswitchNewNwCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2 | |||
| TsmNewIPInfoTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module new IP information. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | ||||
| RsmNewIPInfoEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module new IP configuration information table entry. NOTE: This MIB table is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.
| ||||
| CsmNewIPInfoIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module new IP info index. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | ||||
| CsmNewIPInfoId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.
| ||||
| CsmNewIPInfoExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.
| ||||
| CsmNewIPInfoPowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module specified is powered on or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected..
| ||||
| CsmNewIPAddr | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.6 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory The switch module new IP address. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | ||||
| CsmNewSubnetMask | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.7 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory The switch module new subnet mask. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | ||||
| CsmNewGateway | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.8 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory The switch module new IP gateway. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | ||||
| CsmNewIPConfigMethod | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The switch module new IP configuration method. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
| ||||
| CsmNewIPConfigEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.10 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory A set command enables a new IP configuration that has been previously defined. A get command indicates whether the new IP configuration information has been enabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
| ||||
| NswitchNwProtCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3 | |||
| NswitchNwProtCfgModOne | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1 | |||
| TsmNwProtInfoModOneTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module 1 network protocol (Network Address Translation) information. | ||||
| RsmNwProtInfoModOneEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module 1 network protocol (Network Address Translation) configuration information table entry | ||||
| CsmNwProtInfoModOneIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module 1 network protocol (Network Address Translation) information index. | ||||
| CsmNwProtInfoModOneId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module 1 numeric identifier.
| ||||
| CsmNwProtInfoModOneExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 1 exists or not.
| ||||
| CsmNwProtInfoModOnePowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 1 is powered on or not.
| ||||
| CsmNwProtInfoModOneProtName | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Protocol name | ||||
| CsmNwProtInfoModOneProtID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Protocol ID
| ||||
| CsmNwProtInfoModOneExtPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory External port | ||||
| CsmNwProtInfoModOneIntPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Internal port. | ||||
| CsmNwProtInfoModOneEnable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enable or disable the protocol entry.
| ||||
| SsmNwProtInfoModOneActivate | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SsmNwProtInfoModOneReset | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NswitchNwProtCfgModTwo | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2 | |||
| TsmNwProtInfoModTwoTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module 2 network protocol (Network Address Translation) information. | ||||
| RsmNwProtInfoModTwoEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module 2 network protocol (Network Address Translation) configuration information table entry | ||||
| CsmNwProtInfoModTwoIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module 2 network protocol (Network Address Translation) information index. | ||||
| CsmNwProtInfoModTwoId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module 2 numeric identifier.
| ||||
| CsmNwProtInfoModTwoExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 2 exists or not.
| ||||
| CsmNwProtInfoModTwoPowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 2 is powered on or not.
| ||||
| CsmNwProtInfoModTwoProtName | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Protocol name | ||||
| CsmNwProtInfoModTwoProtID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Protocol ID
| ||||
| CsmNwProtInfoModTwoExtPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory External port | ||||
| CsmNwProtInfoModTwoIntPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Internal port. | ||||
| CsmNwProtInfoModTwoEnable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enable or disable the protocol entry.
| ||||
| SsmNwProtInfoModTwoActivate | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SsmNwProtInfoModTwoReset | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NswitchNwProtCfgModThree | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3 | |||
| TsmNwProtInfoModThreeTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module 3 network protocol (Network Address Translation) information. | ||||
| RsmNwProtInfoModThreeEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module 3 network protocol (Network Address Translation) configuration information table entry | ||||
| CsmNwProtInfoModThreeIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module 3 network protocol (Network Address Translation) information index. | ||||
| CsmNwProtInfoModThreeId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module 3 numeric identifier.
| ||||
| CsmNwProtInfoModThreeExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 3 exists or not.
| ||||
| CsmNwProtInfoModThreePowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 3 is powered on or not.
| ||||
| CsmNwProtInfoModThreeProtName | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Protocol name | ||||
| CsmNwProtInfoModThreeProtID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Protocol ID
| ||||
| CsmNwProtInfoModThreeExtPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory External port | ||||
| CsmNwProtInfoModThreeIntPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Internal port. | ||||
| CsmNwProtInfoModThreeEnable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enable or disable the protocol entry.
| ||||
| SsmNwProtInfoModThreeActivate | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SsmNwProtInfoModThreeReset | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NswitchNwProtCfgModFour | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4 | |||
| TsmNwProtInfoModFourTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module 4 network protocol (Network Address Translation) information. | ||||
| RsmNwProtInfoModFourEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module 3 network protocol (Network Address Translation) configuration information table entry. | ||||
| CsmNwProtInfoModFourIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module 4 network protocol (Network Address Translation) information index. | ||||
| CsmNwProtInfoModFourId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module 4 numeric identifier.
| ||||
| CsmNwProtInfoModFourExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 4 exists or not.
| ||||
| CsmNwProtInfoModFourPowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 4 is powered on or not.
| ||||
| CsmNwProtInfoModFourProtName | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Protocol name | ||||
| CsmNwProtInfoModFourProtID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Protocol ID
| ||||
| CsmNwProtInfoModFourExtPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory External port | ||||
| CsmNwProtInfoModFourIntPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Internal port. | ||||
| CsmNwProtInfoModFourEnable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enable or disable the protocol entry.
| ||||
| SsmNwProtInfoModFourActivate | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SsmNwProtInfoModFourReset | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NswitchNwProtCfgModFive | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5 | |||
| TsmNwProtInfoModFiveTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module 5 network protocol (Network Address Translation) information. | ||||
| RsmNwProtInfoModFiveEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module 5 network protocol (Network Address Translation) configuration information table entry | ||||
| CsmNwProtInfoModFiveIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module 5 network protocol (Network Address Translation) information index. | ||||
| CsmNwProtInfoModFiveId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module 5 numeric identifier.
| ||||
| CsmNwProtInfoModFiveExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 5 exists or not.
| ||||
| CsmNwProtInfoModFivePowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 5 is powered on or not.
| ||||
| CsmNwProtInfoModFiveProtName | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Protocol name | ||||
| CsmNwProtInfoModFiveProtID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Protocol ID
| ||||
| CsmNwProtInfoModFiveExtPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory External port | ||||
| CsmNwProtInfoModFiveIntPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Internal port. | ||||
| CsmNwProtInfoModFiveEnable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enable or disable the protocol entry.
| ||||
| SsmNwProtInfoModFiveActivate | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SsmNwProtInfoModFiveReset | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NswitchNwProtCfgModSix | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6 | |||
| TsmNwProtInfoModSixTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module 6 network protocol (Network Address Translation) information. | ||||
| RsmNwProtInfoModSixEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module 6 network protocol (Network Address Translation) configuration information table entry | ||||
| CsmNwProtInfoModSixIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module 6 network protocol (Network Address Translation) information index. | ||||
| CsmNwProtInfoModSixId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module 6 numeric identifier.
| ||||
| CsmNwProtInfoModSixExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 6 exists or not.
| ||||
| CsmNwProtInfoModSixPowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 6 is powered on or not.
| ||||
| CsmNwProtInfoModSixProtName | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Protocol name | ||||
| CsmNwProtInfoModSixProtID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Protocol ID
| ||||
| CsmNwProtInfoModSixExtPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory External port | ||||
| CsmNwProtInfoModSixIntPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Internal port. | ||||
| CsmNwProtInfoModSixEnable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enable or disable the protocol entry.
| ||||
| SsmNwProtInfoModSixActivate | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SsmNwProtInfoModSixReset | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NswitchNwProtCfgModSeven | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7 | |||
| TsmNwProtInfoModSevenTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module 7 network protocol (Network Address Translation) information. | ||||
| RsmNwProtInfoModSevenEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module 7 network protocol (Network Address Translation) configuration information table entry | ||||
| CsmNwProtInfoModSevenIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module 7 network protocol (Network Address Translation) information index. | ||||
| CsmNwProtInfoModSevenId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module 7 numeric identifier.
| ||||
| CsmNwProtInfoModSevenExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 7 exists or not.
| ||||
| CsmNwProtInfoModSevenPowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 7 is powered on or not.
| ||||
| CsmNwProtInfoModSevenProtName | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Protocol name | ||||
| CsmNwProtInfoModSevenProtID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Protocol ID
| ||||
| CsmNwProtInfoModSevenExtPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory External port | ||||
| CsmNwProtInfoModSevenIntPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Internal port. | ||||
| CsmNwProtInfoModSevenEnable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enable or disable the protocol entry.
| ||||
| SsmNwProtInfoModSevenActivate | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SsmNwProtInfoModSevenReset | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NswitchNwProtCfgModEight | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8 | |||
| TsmNwProtInfoModEightTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module 8 network protocol (Network Address Translation) information. | ||||
| RsmNwProtInfoModEightEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module 8 network protocol (Network Address Translation) configuration information table entry | ||||
| CsmNwProtInfoModEightIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module 8 network protocol (Network Address Translation) information index. | ||||
| CsmNwProtInfoModEightId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module 8 numeric identifier.
| ||||
| CsmNwProtInfoModEightExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 8 exists or not.
| ||||
| CsmNwProtInfoModEightPowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 8 is powered on or not.
| ||||
| CsmNwProtInfoModEightProtName | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Protocol name | ||||
| CsmNwProtInfoModEightProtID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Protocol ID
| ||||
| CsmNwProtInfoModEightExtPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory External port | ||||
| CsmNwProtInfoModEightIntPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Internal port. | ||||
| CsmNwProtInfoModEightEnable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enable or disable the protocol entry.
| ||||
| SsmNwProtInfoModEightActivate | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SsmNwProtInfoModEightReset | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NswitchNwProtCfgModNine | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9 | |||
| TsmNwProtInfoModNineTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module 9 network protocol (Network Address Translation) information. | ||||
| RsmNwProtInfoModNineEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module 9 network protocol (Network Address Translation) configuration information table entry | ||||
| CsmNwProtInfoModNineIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module 9 network protocol (Network Address Translation) information index. | ||||
| CsmNwProtInfoModNineId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module 9 numeric identifier.
| ||||
| CsmNwProtInfoModNineExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 9 exists or not.
| ||||
| CsmNwProtInfoModNinePowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 9 is powered on or not.
| ||||
| CsmNwProtInfoModNineProtName | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Protocol name | ||||
| CsmNwProtInfoModNineProtID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Protocol ID
| ||||
| CsmNwProtInfoModNineExtPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory External port | ||||
| CsmNwProtInfoModNineIntPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Internal port. | ||||
| CsmNwProtInfoModNineEnable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enable or disable the protocol entry.
| ||||
| SsmNwProtInfoModNineActivate | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SsmNwProtInfoModNineReset | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NswitchNwProtCfgModTen | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10 | |||
| TsmNwProtInfoModTenTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1 | NA | mandatory | |
table · not-accessible · mandatory Switch module 10 network protocol (Network Address Translation) information. | ||||
| RsmNwProtInfoModTenEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch module 10 network protocol (Network Address Translation) configuration information table entry | ||||
| CsmNwProtInfoModTenIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module 10 network protocol (Network Address Translation) information index. | ||||
| CsmNwProtInfoModTenId | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module 10 numeric identifier.
| ||||
| CsmNwProtInfoModTenExists | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 10 exists or not.
| ||||
| CsmNwProtInfoModTenPowerState | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the switch module 10 is powered on or not.
| ||||
| CsmNwProtInfoModTenProtName | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Protocol name | ||||
| CsmNwProtInfoModTenProtID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.6 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Protocol ID
| ||||
| CsmNwProtInfoModTenExtPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory External port | ||||
| CsmNwProtInfoModTenIntPort | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Internal port. | ||||
| CsmNwProtInfoModTenEnable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enable or disable the protocol entry.
| ||||
| SsmNwProtInfoModTenActivate | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SsmNwProtInfoModTenReset | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NswitchIPv6Config | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4 | |||
| TsmIPv6ConfigTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1 | NA | mandatory | |
table · not-accessible · mandatory A table of IPv6 configuration options for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | ||||
| RsmIPv6ConfigEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1 | NA | mandatory | |
row · not-accessible · mandatory IPv6 configuration options for a switch module.. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
| ||||
| CsmIPv6ConfigIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module's slot number | ||||
| CsmIPv6ConfigEnabled | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.2 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enables/Disables IPv6 support on the switch module.
| ||||
| CsmIPv6ConfigStatic | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enables/Disables IPv6 static configuration support on the switch module.
| ||||
| CsmDHCPv6ConfigEnabled | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enables/Disables DHCPv6 address configuration support on the switch module.
| ||||
| CsmIPv6ConfigStatelessEnabled | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.5 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Enables/Disables IPv6 stateless auto-configuration support on the switch module.
| ||||
| TsmIPv6AddressTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2 | NA | mandatory | |
table · not-accessible · mandatory A table of assigned IPv6 addresses for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | ||||
| RsmIPv6AddressEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1 | NA | mandatory | |
row · not-accessible · mandatory The assigned IPv6 address for a given switch module NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | ||||
| CsmIPv6AddressIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module's slot number | ||||
| CsmIPv6AddressEntryIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module's address entry index | ||||
| CsmIPv6AddressType | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The address type.
| ||||
| CsmIPv6Address | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.4 | InetAddressIPv6 | RO | mandatory |
column · InetAddressIPv6 · read-only · mandatory The assigned IPv6 address | ||||
| CsmIPv6AddressPrefixLen | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The prefix length for the given address. | ||||
| CsmIPv6AddressDefaultRoute | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.6 | InetAddressIPv6 | RO | mandatory |
column · InetAddressIPv6 · read-only · mandatory The default route used for the given address | ||||
| TsmIPv6StaticConfigTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3 | NA | mandatory | |
table · not-accessible · mandatory Allows configuration of static IPv6 information for supported IO modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | ||||
| RsmIPv6StaticConfigEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1 | NA | mandatory | |
row · not-accessible · mandatory The static IP address assignment information for an IO module. Once the assignement has taken place the address will show up as a row in the smIPv6AddressTable NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
| ||||
| CsmIPv6StaticIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The switch module's slot number | ||||
| CsmIPv6StaticAddress | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.2 | InetAddressIPv6 | RW | mandatory |
column · InetAddressIPv6 · read-write · mandatory The assigned IPv6 address. NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting. | ||||
| CsmIPv6StaticAddressPrefixLen | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The prefix length for the given address. NOTE: If changing with smIPv6StaticAddress and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting. | ||||
| CsmIPv6StaticAddressDefaultRoute | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.4 | InetAddressIPv6 | RW | mandatory |
column · InetAddressIPv6 · read-write · mandatory The default route used for the given address NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddress sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting. | ||||
| NswitchPortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2 | |||
| NswitchModOnePortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1 | |||
| TsmOnePortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1 | NA | mandatory | |
table · not-accessible · mandatory Switch Module 1 port configuration information. NOTE: This option is not supported on all I/O modules. | ||||
| RsmOnePortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Module 1 port configuration information table entry
| ||||
| CsmOnePortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 1 port sequence index. | ||||
| CsmOnePortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module 1 port label | ||||
| CsmOnePortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 1 port type:
External port: This port is connected to external device and is for data traffic.
External management port: This port is solely for external management connection.
This port is not used for data traffic from remote to blades.
External dual port: This external port is used for both data traffic to blades as well as for management.
Blade port: This port is connected to the blade.
Management Module Management port: This port is connected to the Management Module.
Uplink port: This port is configured for up link functionality.
Inter-Module port: This port is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
The port type is either by design connected to another I/O Module, by user configured,
or by AMM setting the port type.
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
and management purposes. The port type is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
| ||||
| CsmOnePortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Current port link setting for Switch Module 1.
| ||||
| CsmOnePortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Current port link state of Switch Module 1.
| ||||
| CsmOnePortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.6 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Set the port speed using the data rate and duplex value. For examples: 100mf: 100 Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smOnePortCfgAvailSpeeds object are applicable to setting this mib object. | ||||
| CsmOnePortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Current port speed of Switch Module 1. | ||||
| CsmOnePortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Available speed setting per port for Switch Module 1. If there is more than one setting, the speeds are separated by a comma and then a space. | ||||
| CsmOnePortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port media type of Switch Module 1.
| ||||
| CsmOnePortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port protocol of Switch Module 1.
| ||||
| CsmOnePortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The width of the port in terms of how many combined cables are present for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | ||||
| CsmOnePortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The length (in meters) of the cable supported by this port for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports. | ||||
| CsmOnePortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory External cable type for this port, for example, active copper or passive fiber. | ||||
| CsmOnePortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The cable manufacturer. | ||||
| CsmOnePortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Compatibility of the external cable that is plugged into the port.
| ||||
| CsmOnePortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Data rate supported for this port.
| ||||
| NswitchModTwoPortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2 | |||
| TsmTwoPortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1 | NA | mandatory | |
table · not-accessible · mandatory Switch Module 2 port configuration information. Note: This option is not supported on all I/O modules. | ||||
| RsmTwoPortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Module 2 port configuration information table entry
| ||||
| CsmTwoPortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 2 port sequence index. | ||||
| CsmTwoPortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module 2 port label | ||||
| CsmTwoPortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 2 port type:
External port: This port is connected to external device and is for data traffic.
External management port: This port is solely for external management connection.
This port is not used for data traffic from remote to blades.
External dual port: This external port is used for both data traffic to blades as well as for management.
Blade port: This port is connected to the blade.
Management Module Management port: This port is connected to the Management Module.
Uplink port: This port is configured for up link functionality.
Inter-Module port: This port is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
The port type is either by design connected to another I/O Module, by user configured,
or by AMM setting the port type.
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
and management purposes. The port type is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
| ||||
| CsmTwoPortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Current port link setting for Switch Module 2.
| ||||
| CsmTwoPortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Current port link state of Switch Module 2.
| ||||
| CsmTwoPortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.6 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smTwoPortCfgAvailSpeeds are applicable to setting this mib object. | ||||
| CsmTwoPortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Current port speed of Switch Module 2. | ||||
| CsmTwoPortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Available speed setting per port for Switch Module 2. If there is more than one setting, the speeds are separated by a comma and then a space. | ||||
| CsmTwoPortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port media type of Switch Module 2.
| ||||
| CsmTwoPortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port protocol of Switch Module 2.
| ||||
| CsmTwoPortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The width of the port in terms of how many combined cables are present for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | ||||
| CsmTwoPortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The length (in meters) of the cable supported by this port for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports. | ||||
| CsmTwoPortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory External cable type for this port, for example, active copper or passive fiber. | ||||
| CsmTwoPortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The cable manufacturer. | ||||
| CsmTwoPortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Compatibility of the external cable that is plugged into the port.
| ||||
| CsmTwoPortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Data rate supported for this port.
| ||||
| NswitchModThreePortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3 | |||
| TsmThreePortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1 | NA | mandatory | |
table · not-accessible · mandatory Switch Module 3 port configuration information. Note: This option is not supported on all I/O modules. | ||||
| RsmThreePortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Module 3 port configuration information table entry
| ||||
| CsmThreePortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 3 port sequence index. | ||||
| CsmThreePortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module 3 port label | ||||
| CsmThreePortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 3 port type:
External port: This port is connected to external device and is for data traffic.
External management port: This port is solely for external management connection.
This port is not used for data traffic from remote to blades.
External dual port: This external port is used for both data traffic to blades as well as for management.
Blade port: This port is connected to the blade.
Management Module Management port: This port is connected to the Management Module.
Uplink port: This port is configured for up link functionality.
Inter-Module port: This port is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
The port type is either by design connected to another I/O Module, by user configured,
or by AMM setting the port type.
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
and management purposes. The port type is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
| ||||
| CsmThreePortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Current port link setting for Switch Module 3.
| ||||
| CsmThreePortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Current port link state of Switch Module 3.
| ||||
| CsmThreePortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.6 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smThreePortCfgAvailSpeeds are applicable to setting this mib object. | ||||
| CsmThreePortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Current port speed of Switch Module 3. | ||||
| CsmThreePortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Available speed setting per port for Switch Module 3. If there is more than one setting, the speeds are separated by a comma and then a space. | ||||
| CsmThreePortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port media type of Switch Module 3.
| ||||
| CsmThreePortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port protocol of Switch Module 3.
| ||||
| CsmThreePortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The width of the port in terms of how many combined cables are present for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | ||||
| CsmThreePortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The length (in meters) of the cable supported by this port for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports. | ||||
| CsmThreePortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory External cable type for this port, for example, active copper or passive fiber. | ||||
| CsmThreePortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The cable manufacturer. | ||||
| CsmThreePortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Compatibility of the external cable that is plugged into the port.
| ||||
| CsmThreePortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Data rate supported for this port.
| ||||
| NswitchModFourPortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4 | |||
| TsmFourPortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1 | NA | mandatory | |
table · not-accessible · mandatory Switch Module 4 port configuration information. Note: This option is not supported on all I/O modules. | ||||
| RsmFourPortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Module 4 port configuration information table entry
| ||||
| CsmFourPortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 4 port sequence index. | ||||
| CsmFourPortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module 4 port label | ||||
| CsmFourPortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 4 port type:
External port: This port is connected to external device and is for data traffic.
External management port: This port is solely for external management connection.
This port is not used for data traffic from remote to blades.
External dual port: This external port is used for both data traffic to blades as well as for management.
Blade port: This port is connected to the blade.
Management Module Management port: This port is connected to the Management Module.
Uplink port: This port is configured for up link functionality.
Inter-Module port: This port is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
The port type is either by design connected to another I/O Module, by user configured,
or by AMM setting the port type.
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
and management purposes. The port type is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
| ||||
| CsmFourPortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Current port link setting for Switch Module 4.
| ||||
| CsmFourPortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Current port link state of Switch Module 4.
| ||||
| CsmFourPortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.6 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smFourPortCfgAvailSpeeds are applicable to setting this mib object. | ||||
| CsmFourPortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Current port speed of Switch Module 4. | ||||
| CsmFourPortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Available speed setting per port for Switch Module 4. If there is more than one setting, the speeds are separated by a comma and then a space. | ||||
| CsmFourPortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port media type of Switch Module 4.
| ||||
| CsmFourPortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port protocol of Switch Module 4.
| ||||
| CsmFourPortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The width of the port in terms of how many combined cables are present for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | ||||
| CsmFourPortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The length (in meters) of the cable supported by this port for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports. | ||||
| CsmFourPortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory External cable type for this port, for example, active copper or passive fiber. | ||||
| CsmFourPortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The cable manufacturer. | ||||
| CsmFourPortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Compatibility of the external cable that is plugged into the port.
| ||||
| CsmFourPortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Data rate supported for this port.
| ||||
| NswitchModFivePortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5 | |||
| TsmFivePortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1 | NA | mandatory | |
table · not-accessible · mandatory Switch Module 5 port configuration information. Note: This option is not supported on all I/O modules. | ||||
| RsmFivePortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Module 5 port configuration information table entry
| ||||
| CsmFivePortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 5 port sequence index. | ||||
| CsmFivePortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module 5 port label | ||||
| CsmFivePortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 5 port type:
External port: This port is connected to external device and is for data traffic.
External management port: This port is solely for external management connection.
This port is not used for data traffic from remote to blades.
External dual port: This external port is used for both data traffic to blades as well as for management.
Blade port: This port is connected to the blade.
Management Module Management port: This port is connected to the Management Module.
Uplink port: This port is configured for up link functionality.
Inter-Module port: This port is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
The port type is either by design connected to another I/O Module, by user configured,
or by AMM setting the port type.
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
and management purposes. The port type is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
| ||||
| CsmFivePortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Current port link setting for Switch Module 5.
| ||||
| CsmFivePortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Current port link state of Switch Module 5.
| ||||
| CsmFivePortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.6 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smFivePortCfgAvailSpeeds are applicable to setting this mib object. | ||||
| CsmFivePortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Current port speed of Switch Module 5. | ||||
| CsmFivePortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Available speed setting per port for Switch Module 5. If there is more than one setting, the speeds are separated by a comma and then a space. | ||||
| CsmFivePortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port media type of Switch Module 5.
| ||||
| CsmFivePortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port protocol of Switch Module 5.
| ||||
| CsmFivePortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The width of the port in terms of how many combined cables are present for Switch Module 5. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | ||||
| CsmFivePortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The length (in meters) of the cable supported by this port for Switch Module 5. A value of 0 indicates this field is not applicable to the switch ports. | ||||
| CsmFivePortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory External cable type for this port, for example, active copper or passive fiber. | ||||
| CsmFivePortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The cable manufacturer. | ||||
| CsmFivePortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Compatibility of the external cable that is plugged into the port.
| ||||
| CsmFivePortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Data rate supported for this port.
| ||||
| NswitchModSixPortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6 | |||
| TsmSixPortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1 | NA | mandatory | |
table · not-accessible · mandatory Switch Module 6 port configuration information. Note: This option is not supported on all I/O modules. | ||||
| RsmSixPortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Module 6 port configuration information table entry
| ||||
| CsmSixPortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 6 port sequence index. | ||||
| CsmSixPortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module 6 port label | ||||
| CsmSixPortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 6 port type:
External port: This port is connected to external device and is for data traffic.
External management port: This port is solely for external management connection.
This port is not used for data traffic from remote to blades.
External dual port: This external port is used for both data traffic to blades as well as for management.
Blade port: This port is connected to the blade.
Management Module Management port: This port is connected to the Management Module.
Uplink port: This port is configured for up link functionality.
Inter-Module port: This port is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
The port type is either by design connected to another I/O Module, by user configured,
or by AMM setting the port type.
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
and management purposes. The port type is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
| ||||
| CsmSixPortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Current port link setting for Switch Module 6.
| ||||
| CsmSixPortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Current port link state of Switch Module 6.
| ||||
| CsmSixPortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.6 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smSixPortCfgAvailSpeeds are applicable to setting this mib object. | ||||
| CsmSixPortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Current port speed of Switch Module 6. | ||||
| CsmSixPortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Available speed setting per port for Switch Module 6. If there is more than one setting, the speeds are separated by a comma and then a space. | ||||
| CsmSixPortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port media type of Switch Module 6.
| ||||
| CsmSixPortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port protocol of Switch Module 6.
| ||||
| CsmSixPortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The width of the port in terms of how many combined cables are present for Switch Module 6. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | ||||
| CsmSixPortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The length (in meters) of the cable supported by this port for Switch Module 6. A value of 0 indicates this field is not applicable to the switch ports. | ||||
| CsmSixPortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory External cable type for this port, for example, active copper or passive fiber. | ||||
| CsmSixPortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The cable manufacturer. | ||||
| CsmSixPortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Compatibility of the external cable that is plugged into the port.
| ||||
| CsmSixPortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Data rate supported for this port.
| ||||
| NswitchModSevenPortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7 | |||
| TsmSevenPortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1 | NA | mandatory | |
table · not-accessible · mandatory Switch Module 7 port configuration information. Note: This option is not supported on all I/O modules. | ||||
| RsmSevenPortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Module 7 port configuration information table entry
| ||||
| CsmSevenPortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 7 port sequence index. | ||||
| CsmSevenPortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module 7 port label | ||||
| CsmSevenPortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 7 port type:
External port: This port is connected to external device and is for data traffic.
External management port: This port is solely for external management connection.
This port is not used for data traffic from remote to blades.
External dual port: This external port is used for both data traffic to blades as well as for management.
Blade port: This port is connected to the blade.
Management Module Management port: This port is connected to the Management Module.
Uplink port: This port is configured for up link functionality.
Inter-Module port: This port is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
The port type is either by design connected to another I/O Module, by user configured,
or by AMM setting the port type.
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
and management purposes. The port type is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
| ||||
| CsmSevenPortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Current port link setting for Switch Module 7.
| ||||
| CsmSevenPortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Current port link state of Switch Module 7.
| ||||
| CsmSevenPortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.6 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smSevenPortCfgAvailSpeeds are applicable to setting this mib object. | ||||
| CsmSevenPortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Current port speed of Switch Module 7. | ||||
| CsmSevenPortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Available speed setting per port for Switch Module 7. If there is more than one setting, the speeds are separated by a comma and then a space. | ||||
| CsmSevenPortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port media type of Switch Module 7.
| ||||
| CsmSevenPortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port protocol of Switch Module 7.
| ||||
| CsmSevenPortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The width of the port in terms of how many combined cables are present for Switch Module 7. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | ||||
| CsmSevenPortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The length (in meters) of the cable supported by this port for Switch Module 7. A value of 0 indicates this field is not applicable to the switch ports. | ||||
| CsmSevenPortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory External cable type for this port, for example, active copper or passive fiber. | ||||
| CsmSevenPortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The cable manufacturer. | ||||
| CsmSevenPortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Compatibility of the external cable that is plugged into the port.
| ||||
| CsmSevenPortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Data rate supported for this port.
| ||||
| NswitchModEightPortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8 | |||
| TsmEightPortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1 | NA | mandatory | |
table · not-accessible · mandatory Switch Module 8 port configuration information. Note: This option is not supported on all I/O modules. | ||||
| RsmEightPortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Module 8 port configuration information table entry
| ||||
| CsmEightPortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 8 port sequence index. | ||||
| CsmEightPortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module 8 port label | ||||
| CsmEightPortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 8 port type:
External port: This port is connected to external device and is for data traffic.
External management port: This port is solely for external management connection.
This port is not used for data traffic from remote to blades.
External dual port: This external port is used for both data traffic to blades as well as for management.
Blade port: This port is connected to the blade.
Management Module Management port: This port is connected to the Management Module.
Uplink port: This port is configured for up link functionality.
Inter-Module port: This port is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
The port type is either by design connected to another I/O Module, by user configured,
or by AMM setting the port type.
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
and management purposes. The port type is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
| ||||
| CsmEightPortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Current port link setting for Switch Module 8.
| ||||
| CsmEightPortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Current port link state of Switch Module 8.
| ||||
| CsmEightPortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.6 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smEightPortCfgAvailSpeeds are applicable to setting this mib object. | ||||
| CsmEightPortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Current port speed of Switch Module 8. | ||||
| CsmEightPortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Available speed setting per port for Switch Module 8. If there is more than one setting, the speeds are separated by a comma and then a space. | ||||
| CsmEightPortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port media type of Switch Module 8.
| ||||
| CsmEightPortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port protocol of Switch Module 8.
| ||||
| CsmEightPortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The width of the port in terms of how many combined cables are present for Switch Module 8. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | ||||
| CsmEightPortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The length (in meters) of the cable supported by this port for Switch Module 8. A value of 0 indicates this field is not applicable to the switch ports. | ||||
| CsmEightPortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory External cable type for this port, for example, active copper or passive fiber. | ||||
| CsmEightPortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The cable manufacturer. | ||||
| CsmEightPortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Compatibility of the external cable that is plugged into the port.
| ||||
| CsmEightPortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Data rate supported for this port.
| ||||
| NswitchModNinePortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9 | |||
| TsmNinePortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1 | NA | mandatory | |
table · not-accessible · mandatory Switch Module 9 port configuration information. Note: This option is not supported on all I/O modules. | ||||
| RsmNinePortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Module 9 port configuration information table entry
| ||||
| CsmNinePortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 9 port sequence index. | ||||
| CsmNinePortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module 9 port label | ||||
| CsmNinePortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 9 port type:
External port: This port is connected to external device and is for data traffic.
External management port: This port is solely for external management connection.
This port is not used for data traffic from remote to blades.
External dual port: This external port is used for both data traffic to blades as well as for management.
Blade port: This port is connected to the blade.
Management Module Management port: This port is connected to the Management Module.
Uplink port: This port is configured for up link functionality.
Inter-Module port: This port is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
The port type is either by design connected to another I/O Module, by user configured,
or by AMM setting the port type.
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
and management purposes. The port type is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
| ||||
| CsmNinePortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Current port link setting for Switch Module 9.
| ||||
| CsmNinePortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Current port link state of Switch Module 9.
| ||||
| CsmNinePortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.6 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smNinePortCfgAvailSpeeds are applicable to setting this mib object. | ||||
| CsmNinePortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Current port speed of Switch Module 9. | ||||
| CsmNinePortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Available speed setting per port for Switch Module 9. If there is more than one setting, the speeds are separated by a comma and then a space. | ||||
| CsmNinePortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port media type of Switch Module 9.
| ||||
| CsmNinePortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port protocol of Switch Module 9.
| ||||
| CsmNinePortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The width of the port in terms of how many combined cables are present for Switch Module 9. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | ||||
| CsmNinePortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The length (in meters) of the cable supported by this port for Switch Module 9. A value of 0 indicates this field is not applicable to the switch ports. | ||||
| CsmNinePortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory External cable type for this port, for example, active copper or passive fiber. | ||||
| CsmNinePortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The cable manufacturer. | ||||
| CsmNinePortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Compatibility of the external cable that is plugged into the port.
| ||||
| CsmNinePortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Data rate supported for this port.
| ||||
| NswitchModTenPortCfg | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10 | |||
| TsmTenPortCfgTable | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1 | NA | mandatory | |
table · not-accessible · mandatory Switch Module 10 port configuration information. Note: This option is not supported on all I/O modules. | ||||
| RsmTenPortCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Module 10 port configuration information table entry
| ||||
| CsmTenPortCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 10 port sequence index. | ||||
| CsmTenPortCfgLabel | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Switch Module 10 port label | ||||
| CsmTenPortCfgType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module 10 port type:
External port: This port is connected to external device and is for data traffic.
External management port: This port is solely for external management connection.
This port is not used for data traffic from remote to blades.
External dual port: This external port is used for both data traffic to blades as well as for management.
Blade port: This port is connected to the blade.
Management Module Management port: This port is connected to the Management Module.
Uplink port: This port is configured for up link functionality.
Inter-Module port: This port is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
The port type is either by design connected to another I/O Module, by user configured,
or by AMM setting the port type.
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
and management purposes. The port type is either by design connected to another I/O Module,
by user configured, or by AMM setting the port type.
| ||||
| CsmTenPortCfgLinkSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Current port link setting for Switch Module 10.
| ||||
| CsmTenPortCfgLinkState | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Current port link state of Switch Module 10.
| ||||
| CsmTenPortCfgSpeedSetting | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.6 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smTenPortCfgAvailSpeeds are applicable to setting this mib object. | ||||
| CsmTenPortCfgSpeedStatus | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Current port speed of Switch Module 10. | ||||
| CsmTenPortCfgAvailSpeeds | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Available speed setting per port for Switch Module 10. If there is more than one setting, the speeds are separated by a comma and then a space. | ||||
| CsmTenPortCfgMedia | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port media type of Switch Module 10.
| ||||
| CsmTenPortCfgProtocol | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port protocol of Switch Module 10.
| ||||
| CsmTenPortCfgWidth | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The width of the port in terms of how many combined cables are present for Switch Module 10. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | ||||
| CsmTenPortCfgCableLength | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The length (in meters) of the cable supported by this port for Switch Module 10. A value of 0 indicates this field is not applicable to the switch ports. | ||||
| CsmTenPortCfgCableType | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory External cable type for this port, for example, active copper or passive fiber. | ||||
| CsmTenPortCfgVendorName | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The cable manufacturer. | ||||
| CsmTenPortCfgCompatibility | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Compatibility of the external cable that is plugged into the port.
| ||||
| CsmTenPortCfgDataRate | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Data rate supported for this port.
| ||||
| NraidControllerConfig | 1.3.6.1.4.1.2.3.51.2.22.3.3 | |||
| TraidControllerTable | 1.3.6.1.4.1.2.3.51.2.22.3.3.1 | NA | mandatory | |
table · not-accessible · mandatory RAID Controller control table. | ||||
| RraidControllerEntry | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1 | NA | mandatory | |
| CraidControllerIndex | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory RAID Controller control table index. This MIB object is for SAS Controller Modules only. | ||||
| CraidControllerId | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The I/O Module numeric identifier for the SAS Controller Module. This MIB object is for SAS Controller Modules only.
| ||||
| CraidControllerExists | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the I/O Module specified for the RAID Controller exists or not. This MIB object is for SAS Controller Modules only.
| ||||
| CraidControllerPowerState | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only.
| ||||
| CraidControllerMACAddress | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The MAC address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. | ||||
| CraidControllerSasID | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The hardware VPD SAS ID for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. | ||||
| CraidControllerPingRequest | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Sends a ping to the current IP address of the RAID Controller network interface. This MIB object can not be set, if AMM grants I/O Module the Protected Mode permission and the module goes into Protected Mode. NOTE: Value returned for the GET command is meaningless for this MIB object This MIB object is for SAS Controller Modules only. | ||||
| NraidControllerNetworkCfg | 1.3.6.1.4.1.2.3.51.2.22.3.3.2 | |||
| TrcCurrentIPInfoTable | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1 | NA | mandatory | |
table · not-accessible · mandatory RAID Controller current IP table. This MIB object is for SAS Controller Modules only. | ||||
| RrcCurrentIPInfoEntry | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1 | NA | mandatory | |
row · not-accessible · mandatory RAID Controller current IP table entry. This MIB object is for SAS Controller Modules only.
| ||||
| CrcCurrentIPInfoIndex | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory RAID Controller current IP table index. This MIB object is for SAS Controller Modules only. | ||||
| CrcCurrentIPInfoId | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The I/O Module numeric identifier for the RAID Controller. This MIB object is for SAS Controller Modules only.
| ||||
| CrcCurrentIPInfoExists | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the I/O Module exists or not. This MIB object is for SAS Controller Modules only.
| ||||
| CrcCurrentIPInfoPowerState | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only.
| ||||
| CrcCurrentIPAddr | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.5 | IpAddress | RO | mandatory |
column · IpAddress · read-only · mandatory The current IP address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. | ||||
| CrcCurrentSubnetMask | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.6 | IpAddress | RO | mandatory |
column · IpAddress · read-only · mandatory The current subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. | ||||
| CrcCurrentGateway | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.7 | IpAddress | RO | mandatory |
column · IpAddress · read-only · mandatory The current subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. | ||||
| CrcCurrentIPConfigMethod | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.8 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current IP gateway for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
| ||||
| CrcCurrentRaidedVlanId | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current virtual LAN ID for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. | ||||
| TrcNewIPInfoTable | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2 | NA | mandatory | |
table · not-accessible · mandatory RAID Controller new IP configuration table. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | ||||
| RrcNewIPInfoEntry | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1 | NA | mandatory | |
row · not-accessible · mandatory RAID Controller new IP configuration information table entry. This MIB object is for SAS Controller Modules only. NOTE: This MIB table is not applicable to modules that are running in Network Address Translation (NAT) Mode.
| ||||
| CrcNewIPInfoIndex | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory RAID Controller new IP configuration information index. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | ||||
| CrcNewIPInfoId | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The I/O Module numeric identifier for the RAID Controller. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
| ||||
| CrcNewIPInfoExists | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the I/O Module exists or not. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
| ||||
| CrcNewIPInfoPowerState | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
| ||||
| CrcNewIPAddr | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.5 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory The new IP address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | ||||
| CrcNewSubnetMask | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.6 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory The new subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | ||||
| CrcNewGateway | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.7 | IpAddress | RW | mandatory |
column · IpAddress · read-write · mandatory The new IP gateway for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | ||||
| CrcNewIPConfigMethod | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The new IP configuration method for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: The value 'DHCP' can not be used to set. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
| ||||
| CrcNewIPConfigEnableDisable | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.11 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory A set command enables new IP configurations that have been defined. A get command indicates whether new IP configurations that have been enabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
| ||||
| NchassisTopology | 1.3.6.1.4.1.2.3.51.2.22.4 | |||
| SchassisResponseVersion | 1.3.6.1.4.1.2.3.51.2.22.4.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Chassis response version. | ||||
| SchassisFlags | 1.3.6.1.4.1.2.3.51.2.22.4.2 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Chassis flags. 1 = a server blade chassis, 0 = a rack or standalone chassis.
| ||||
| SchassisName | 1.3.6.1.4.1.2.3.51.2.22.4.3 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The name of the active MM as a null terminated string. | ||||
| SchassisNoOfFPsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.18 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Number of fan packs (FPs) supported. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | ||||
| SchassisNoOfPBsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.19 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Number of processor blades (PBs) supported. | ||||
| SchassisNoOfSMsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.20 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Number of switch modules (SMs) supported. | ||||
| SchassisNoOfMMsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.21 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Number of management modules (MMs) supported. | ||||
| SchassisNoOfPMsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.22 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Number of power modules (PMs) supported. | ||||
| SchassisNoOfMTsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.23 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Number of media trays (MTs) supported. | ||||
| SchassisNoOfBlowersSupported | 1.3.6.1.4.1.2.3.51.2.22.4.24 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Number of blowers supported. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| SchassisPBsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.25 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | ||||
| SchassisSMsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.29 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011' for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT. | ||||
| SchassisMMsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.30 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The management modules that are installed on the chassis. The management modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of management modules supported. If a management module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a management module is installed in bay 1, and 2 management modules are supported, the string would look like '10'. | ||||
| SchassisPMsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.31 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'. | ||||
| SchassisMTInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.32 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates whether at least one media tray (MT) is installed.
| ||||
| SchassisBlowersInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.33 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The blowers that are installed on the chassis. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices. | ||||
| SchassisActiveMM | 1.3.6.1.4.1.2.3.51.2.22.4.34 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The active management module (MM). | ||||
| SchassisKVMOwner | 1.3.6.1.4.1.2.3.51.2.22.4.35 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The blade that currently owns the keyboard/video/monitor (KVM). 0 = the KVM devices are owned by the management module. | ||||
| SchassisMediaTrayOwner | 1.3.6.1.4.1.2.3.51.2.22.4.36 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The blade that currently owns the media tray. 0 = the media tray is owned by the management module. | ||||
| SchassisFPsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.37 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The fan packs that are installed on the chassis. The fan packs are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of fan packs supported. If a fan pack is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if fan packs are installed in bays 1 and 3, and 4 fan packs are supported, the string would look like '1010'. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | ||||
| SchassisType | 1.3.6.1.4.1.2.3.51.2.22.4.38 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The type of the chassis. The BladeCenterS chassis and BladeCenterE are part of the bladeCenterOrBladeCenterH type. This MIB object should be used in conjunction with chassisSubType MIB object to determine the characteristic of the chassis.
| ||||
| SchassisSubtype | 1.3.6.1.4.1.2.3.51.2.22.4.39 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The subtype of the chassis. This MIB object should be used in conjunction with chassisType MIB object to determine the characteristic of the chassis.
| ||||
| SchassisNoOfFBsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.40 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Number of Front Bezel (FBs) supported. | ||||
| SchassisNoOfAPsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.41 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Number of Alarm Panel (APs) supported. | ||||
| SchassisNoOfNCsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.42 | INTEGER | RO | deprecated |
scalar · INTEGER · read-only · deprecated Number of Network Clocks (NCs) supported. | ||||
| SchassisNoOfMXsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.43 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Number of Multiplexer Expansion modules (MXs) supported. | ||||
| SchassisNoOfMMIsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.44 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Number of management module interposers (MMIs) supported. | ||||
| SchassisNoOfSMIsSupported | 1.3.6.1.4.1.2.3.51.2.22.4.45 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Number of switch module interposers (SMIs) supported. | ||||
| SchassisNoOfFBsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.46 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The return value of '1'indicates the front bezel is installed on the chassis. The value of '0' indicates the front bezel is not installed. | ||||
| SchassisNoOfAPsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.47 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The return value of '1'indicates the alarm panel is installed on the chassis. The value of '0' indicates the alarm panel is not installed. | ||||
| SchassisNoOfNCsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.48 | OCTET STRING | RO | deprecated |
scalar · OCTET STRING · read-only · deprecated The network clock cards that are installed on the chassis. The network clock cards are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of network clock cards supported. If a network clock card is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a network clock card is installed in bays 1, and 2 network clock cards are supported, the string would look like '10'. | ||||
| SchassisNoOfMXsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.49 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The Multiplexer Expansion Modules that are installed on the chassis. The Multiplexer Expansion Modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of Multiplexer Expansion Modules supported. If a Multiplexer Expansion Module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if Multiplexer Expansion Module is installed in bays 1, and 2 Multiplexer Expansion Modules are supported, the string would look like '10'. | ||||
| SchassisNoOfMMIsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.50 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The flex cables that are installed on the chassis. The flex cables are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of flex cables supported. If a flex cable is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if flex cable is installed in bays 1, and 2 flex cables are supported, the string would look like '10'. | ||||
| SchassisNoOfSMIsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.51 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The interposers that are installed on the chassis. The interposers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of interposers supported. If an interposer is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if interposer is installed in bays 1, and 10 interposers are supported, the string would look like '1000000000'. | ||||
| SchassisNoOfMTsInstalled | 1.3.6.1.4.1.2.3.51.2.22.4.52 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory The media trays that are installed on the chassis. The media trays are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of media trays supported. If a media tray is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if media trays are installed in bays 1, and 2 media trays are, the string would look like '10'. | ||||
| NmanagementModule | 1.3.6.1.4.1.2.3.51.2.22.5 | |||
| TmmStatusTable | 1.3.6.1.4.1.2.3.51.2.22.5.1 | NA | mandatory | |
table · not-accessible · mandatory Table of the management module status. For consistent results, view as a table and not as individual entries. | ||||
| RmmStatusEntry | 1.3.6.1.4.1.2.3.51.2.22.5.1.1 | NA | mandatory | |
row · not-accessible · mandatory Management module status entry. For consistent results, view as a table and not as individual entries.
| ||||
| CmmStatusIndex | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Management module status index. | ||||
| CmmPresent | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Management module current status.
| ||||
| CmmExtIpAddress | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.3 | IpAddress | RO | mandatory |
column · IpAddress · read-only · mandatory Management module external IP address. NOTE: The IPv6 addresses assigned to the AMM may be viewed with the extEthernetInterfaceIPv6 objects | ||||
| CmmPrimary | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if this Management module is a primary or not. NOTE: If there is no standby MM, this value defaults to primary.
| ||||
| CmmHealthState | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The health state for the management module. 0 = unknown, 1 = good, 2 = warning, 3 = bad.
| ||||
| Nstorage | 1.3.6.1.4.1.2.3.51.2.22.6 | |||
| NstorageStatus | 1.3.6.1.4.1.2.3.51.2.22.6.1 | |||
| TstorageStatusTable | 1.3.6.1.4.1.2.3.51.2.22.6.1.1 | NA | mandatory | |
table · not-accessible · mandatory Table of the storage module status. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | ||||
| RstorageStatusEntry | 1.3.6.1.4.1.2.3.51.2.22.6.1.1.1 | NA | mandatory | |
| CstorageStatusIndex | 1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Storage device status table index. | ||||
| CstorageBayNumber | 1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Bay number of the Storage device. | ||||
| CstorageState | 1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Storage device state.
| ||||
| CstorageName | 1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the storage device. | ||||
| NstorageConfiguration | 1.3.6.1.4.1.2.3.51.2.22.6.2 | |||
| NstorageSwitchConfiguration | 1.3.6.1.4.1.2.3.51.2.22.6.2.1 | |||
| TstorageSwitchZoneCfgTable | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1 | NA | mandatory | |
table · not-accessible · mandatory Table of all the zone configurations stored on switch
modules. For consistent results, view as a table and
not as individual entries.
Before activating a new zone configuration via the switchActiveZoneCfg
object, a user must consider the following:
1) Changing the zone configuration may cause disruption in the storage
access of blades connected to this SAS Module. It is highly recommended
that you first ensure that the blades have completed all storage accesses.
You may want to shutdown the blade OS prior to changing your zone configuration.
2) When selecting a zone configuration, ensure that it is appropriate
for the number of SAS switches installed in your chassis. This can
be determined from the switchZoneCfgDescription text.
3) When selecting a zone configuration, ensure that it exists first on
all SAS switches. This can be determined by querying the
storageSwitchZoneCfgTable. In addition, for user-defined zone
configurations, even if the number is the same, ensure that the
actual zone configurations are identical or compatible. You will need
to use an application, such as the Switch Configuration Manager (SCM)
to verify this.
4) All SAS switches must be in operational state prior to activating a
new zone configuration. This can be determined by querying the
activeZoneCfgNumberBySwitch object and ensuring that none of the
2xx codes are returned. | ||||
| RstorageSwitchZoneCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Module Zone Configuration Management Entry.
| ||||
| CswitchZoneCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch module zone configuration table index. | ||||
| CswitchZoneCfgBayNumber | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric switch bay number. | ||||
| CswitchZoneCfgNumber | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The zone configuration number, also referred to as the configuration store number. | ||||
| CswitchZoneCfgStatus | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The status of the zone configuration. Only one configuration is 'Active', others are in 'nonActive' status. When a zone configuration is active on a switch, the status may temporarily indicate pending(2) as it transitions from nonActive(0) to active (1).
| ||||
| CswitchZoneCfgType | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The type of the zone configuration. Predefined are read-only static configurations, and userdefined are read-write configurations that can be created and modified using the Switch Configuration Manager application.
| ||||
| CswitchZoneCfgName | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A short descriptive name for the zone configuration. | ||||
| CswitchZoneCfgDescription | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A detailed description for the zone configuration. | ||||
| CswitchZoneCfgDate | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The date the zone configuration was created. | ||||
| CswitchActiveZoneCfg | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.9 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory An object used to activate a particular zone configuration.
NOTE: Value returned for the GET command is meaningless
for this MIB object.
| ||||
| TstorageSwitchActiveZoneCfgTable | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.2 | NA | mandatory | |
table · not-accessible · mandatory Table showing the zone configuration that is currently active on a given switch module. For consistent results, view as a table and not as individual entries. | ||||
| RstorageSwitchActiveZoneCfgEntry | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1 | NA | mandatory | |
| CactiveZoneCfgIndex | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Active zone configurations table index. | ||||
| CactiveZoneCfgBayNumber | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Bay number of the switch module where active zone configurations exist. | ||||
| CactiveZoneCfgNumberBySwitch | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The zone configuration number active on this SAS switch module as reported by the switch module. If this number differs from the value of the activeZoneCfgNumberByMM object for the same switch, this may indicate a configuration problem. The zone configuration number is also referred to as the zone configuration store. NOTE: 0 = No zone configuration is active on this I/O Module. 253 = I/O module is discovering zone information. 254 = I/O Module is not powered on or in a fault state. 255 = notApplicable. | ||||
| CactiveZoneCfgNumberByMM | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The zone configuration number active on this SAS switch module as known by the management module. If this number differs from the value of the activeZoneCfgNumberBySwitch object for the same switch, this may indicate a configuration problem. The zone configuration number is also referred to as the zone configuration store. NOTE: 0 = No zone configuration is active on this I/O Module. 255 = notApplicable. | ||||
| SswitchZoneCfgActivation | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory This object provides a quick means of activating a valid zone
configuration on all active SAS switches. The zone configuration
to be activated is specified as the value of the SET and can be
obtained from the switchZoneCfgNumber object.
The zone configuration number is also referred to as the zone
configuration store.
Before activating a new zone configuration, a user must consider
the following:
1) Changing the zone configuration may cause disruption in the storage
access of blades connected to this SAS Module. It is highly recommended
that you first ensure that the blades have completed all storage accesses.
You may want to shutdown the blade OS prior to changing your zone configuration.
2) When selecting a zone configuration, ensure that it is appropriate
for the number of SAS switches installed in your chassis. This can
be determined from the switchZoneCfgDescription text.
3) When selecting a zone configuration, ensure that it exists first on
all SAS switches. This can be determined by querying the
storageSwitchZoneCfgTable. In addition, for user-defined zone
configurations, even if the number is the same, ensure that the
actual zone configurations are identical or compatible. You will need
to use an application, such as the Switch Configuration Manager (SCM)
to verify this.
4) All SAS switches must be in operational state prior to activating a
new zone configuration. This can be determined by querying the
activeZoneCfgNumberBySwitch object and ensuring that none of the
2xx codes are returned.
NOTE: Value returned for the GET command is meaningless
for this MIB object.
If any of the switches are not activated, an error response
will be returned. | ||||
| NfirmwareInformation | 1.3.6.1.4.1.2.3.51.2.22.8 | |||
| NsmFirmwareInformation | 1.3.6.1.4.1.2.3.51.2.22.8.1 | |||
| TsmFirmwareInfoTable | 1.3.6.1.4.1.2.3.51.2.22.8.1.1 | NA | mandatory | |
table · not-accessible · mandatory Switch Module firmware image information. This table is only applicable to modules that support multiple images | ||||
| RsmFirmwareInfoEntry | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1 | NA | mandatory | |
row · not-accessible · mandatory Switch Module firmware image information table entry
| ||||
| CsmFirmwareInfoIndex | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Sequence index in the firmware table. | ||||
| CsmFirmwareInfoModIndex | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module number. | ||||
| CsmFirmwareInfoImageIndex | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Switch Module firmware image index. | ||||
| CsmFirmwareInfoImageName | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.4 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Switch Module firmware image name | ||||
| NfirmwareUpdate | 1.3.6.1.4.1.2.3.51.2.22.9 | |||
| SfirmwareUpdateTarget | 1.3.6.1.4.1.2.3.51.2.22.9.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Target module whose firmware will be updated. NOTE: Some switch modules do not allow firmware update. When firmware update is attempted on those switch modules, the agent will report an error.
| ||||
| SfirmwareUpdateTftpServer | 1.3.6.1.4.1.2.3.51.2.22.9.2 | OCTET STRING (SIZE (0..63)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..63)) · read-write · mandatory If flashing via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2). NOTE: IPv6 numeric addresses must be enclosed with brackets (e.g. [fe80::5652:ff:fe50:53b6]). | ||||
| SfirmwareUpdateFileName | 1.3.6.1.4.1.2.3.51.2.22.9.3 | OCTET STRING (SIZE (0..254)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..254)) · read-write · mandatory File name of the firmware file. | ||||
| SfirmwareUpdateStart | 1.3.6.1.4.1.2.3.51.2.22.9.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Start updating the firmware of the specified target module. Using execute or execute-with-reboot will cause the SNMP client to wait for the firmware update to complete. Using execute-nowait or execute-with-reboot-nowait will not cause the SNMP client to wait for the update to complete. Instead it will flash the firmware in the background. Note 1: If the execute-with-reboot or execute-with-reboot-nowait option is selected, the target will reset after a successful flash. This option is only valid if the firmwareUpdateTarget object is set to managementModule. Note 2: If flashing from a remote file, then both firmwareUpdateServer and firmwareUpdateFileName must be set. Otherwise if flashing via the legacy method using a tftp server, then both firmwareUpdateTftpServer and firmwareUpdateFileName must be set. Note 3: Depending on the target, it might take up to several minutes for the flash update to complete. Do not reset the target until the control has been returned. At this point, the results will be displayed. Note 4: Use firmwareUpdateStatus to confirm the status of the last firmware update initiated by SNMP method. The Management Module must be restarted for the new firmware to take affect. Note 5: If data encryption is currently enabled on this MM, and you update the MM firmware to a level which does not support data encryption, you will lose all your configuration settings as a result. Note 6: Since some I/O Module types use the AMM TFTP server for firmware file transfer during the firmware update process, the tftpEnable MIB object must be set to enable prior to updating the firmware for these modules. Note 7: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this AMM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| SfirmwareUpdateStatus | 1.3.6.1.4.1.2.3.51.2.22.9.5 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Get the status of the last firmware update which was initiated through SNMP method. | ||||
| SstandbyFirmwareUpdateStatus | 1.3.6.1.4.1.2.3.51.2.22.9.6 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory Get the current status of the firmware update for the standby AMM. NOTE: This only applies to systems with a standby AMM. | ||||
| SfirmwareImageNumber | 1.3.6.1.4.1.2.3.51.2.22.9.7 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory If the module can upload more than one image, an image number must be specified after setting the firmware target. Please refer to the firmwareInformation section. | ||||
| SfirmwareActiveImage | 1.3.6.1.4.1.2.3.51.2.22.9.8 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory If the module can upload more than one image, an active image number must be specified. Please refer to the firmwareInformation section. NOTE: Value returned for the GET command is meaningless for this MIB object. | ||||
| SfirmwareUpdateServer | 1.3.6.1.4.1.2.3.51.2.22.9.9 | OCTET STRING (SIZE (0..254)) | RW | mandatory |
scalar · OCTET STRING (SIZE (0..254)) · read-write · mandatory Contains the fully qualified remote location of the firmware
packet file. Use firmwareUpdateFileName to specify the filename.
A fully qualified remote location contains a supported
protocol followed by a colon and two slashes (//), userid and
password separated by a colon for login authentication, an
@ sign, followed by the hostname or IP address of the
server where the packet file resides, followed by an optional
port number to the hostname, and the full pathname to the file.
Note that if the port number is specified, it must be
separated with the hostname (or IP address) by a colon.
The AMM currently supports the following protocols:
TFTP, FTP, FTPS, HTTP and HTTPS.
The complete format of a fully qualified remote location is:
<protocol>://<userid:password>@<hostname:port>/<pathname>
An example of a fully qualified remote location can be:
ftp://USERID:[email protected]:30045/tmp
where the ftp protocol will be used for transferring the file in
this location, username is USERID, password is
PASSW0RD, host IP address is 192.168.0.2, port number is
30045, and the full pathname for the packet file is /tmp.
and firmwareUpdateFileName is set to: CNETCMUS.pkt
Some protocols do not need the username, password, and
the port number, so the minimum requirement for a fully
qualified location can be: <protocol>://<hostname>/<pathname>. | ||||
| NremoteChassis | 1.3.6.1.4.1.2.3.51.2.22.10 | |||
| TremoteChassisTable | 1.3.6.1.4.1.2.3.51.2.22.10.1 | NA | mandatory | |
table · not-accessible · mandatory Table of remote chassis information. | ||||
| RremoteChassisEntry | 1.3.6.1.4.1.2.3.51.2.22.10.1.1 | NA | mandatory | |
| CremoteChassisIndex | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Remote chassis discovery sequence index. | ||||
| CsystemName | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory System name for this discovery management module. | ||||
| CsystemStatus | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory System status summary (chassis).
| ||||
| CmmType | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Service processor type. | ||||
| CmmSerial | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module serial number. | ||||
| CmmFru | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Management module Field-Replaceable number. | ||||
| CmmIp | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.7 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory The IPv4 compliant address of the management module. | ||||
| CchassisSerial | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.8 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Chassis serial number. | ||||
| CchassisFru | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Chassis Field-Replaceable number. | ||||
| CchassisMachineTypeMode | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Chassis machine type and model number. | ||||
| CchassisUuid | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Chassis unique identifier. | ||||
| CfirmwareVersion | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Firmware version of the discovery management module. | ||||
| CipStatus | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.13 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory A flag to state if IPv4 and IPv6 are enabled
| ||||
| Cipv6Addresses | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The IPv6 addresses configured for the chassis. | ||||
| SchassisDiscovery | 1.3.6.1.4.1.2.3.51.2.22.10.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Discovery of remote Chassis. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| NfileManagement | 1.3.6.1.4.1.2.3.51.2.22.11 | |||
| NfileTopology | 1.3.6.1.4.1.2.3.51.2.22.11.1 | |||
| ScurrentDirectory | 1.3.6.1.4.1.2.3.51.2.22.11.1.1 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Specifies the directory name for listing the requested files. | ||||
| TfileDetailsTable | 1.3.6.1.4.1.2.3.51.2.22.11.1.2 | NA | mandatory | |
table · not-accessible · mandatory A table of all the files in the specified directory. For consistent results, view as a table and not as individual entries. | ||||
| RfileDetailsEntry | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1 | NA | mandatory | |
row · not-accessible · mandatory File details entry. For consistent results, view as a table and not as individual entries.
| ||||
| CfileIndex | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory File sequence index. | ||||
| CfileName | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory File name. | ||||
| CfileLastUpdate | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Date of the latest file update. | ||||
| CfileSize | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory File size in bytes. | ||||
| SfileManagementCmd | 1.3.6.1.4.1.2.3.51.2.22.11.3 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory This field will execute the selected operations on the files. The following operation is supported: DEL name - delete a file Examples: - to delete the file named switch.config in tftproot directory set the value to 'DEL tftproot/switch.config' NOTE: Value returned for the GET command is meaningless for this MIB object. | ||||
| SfileSystemSpaceAvailable | 1.3.6.1.4.1.2.3.51.2.22.11.6 | OCTET STRING | RO | mandatory |
scalar · OCTET STRING · read-only · mandatory This field displays the available space of the AMM file system. | ||||
| NcomponentMonitors | 1.3.6.1.4.1.2.3.51.2.22.37 | |||
| TcomponentMACAddressTable | 1.3.6.1.4.1.2.3.51.2.22.37.11 | NA | mandatory | |
table · not-accessible · mandatory Table of MAC address VPD information for each component. | ||||
| RcomponentMACAddressEntry | 1.3.6.1.4.1.2.3.51.2.22.37.11.1 | NA | mandatory | |
row · not-accessible · mandatory Component MAC address table entry | ||||
| CcomponentMACAddressTopologyPath | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.1 | OCTET STRING (SIZE (0..100)) | RO | mandatory |
column · OCTET STRING (SIZE (0..100)) · read-only · mandatory The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card | ||||
| CcomponentMACAddressIndex | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Each component may have one or more MAC address VPD values associated with it, and this index object identifies the particular instance. | ||||
| CcomponentMACAddressName | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the component as a null terminated string. | ||||
| CcomponentMACAddress | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The MAC address VPD value for this component and index. The value is a null terminated string. | ||||
| Nservice | 1.3.6.1.4.1.2.3.51.2.23 | |||
| NserviceConfig | 1.3.6.1.4.1.2.3.51.2.23.1 | |||
| SdebugEnable | 1.3.6.1.4.1.2.3.51.2.23.1.3 | INTEGER | RW | deprecated |
scalar · INTEGER · read-write · deprecated Disable/Enable AMM debugging with USB key by service personnel.
| ||||
| NbladeServiceData | 1.3.6.1.4.1.2.3.51.2.23.3 | |||
| TbladeServiceDataTable | 1.3.6.1.4.1.2.3.51.2.23.3.1 | NA | mandatory | |
table · not-accessible · mandatory Table of blade service data information. | ||||
| RbladeServiceDataEntry | 1.3.6.1.4.1.2.3.51.2.23.3.1.1 | NA | mandatory | |
| CserviceDataIndex | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Blade service date index. | ||||
| CserviceDataBladeId | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The numeric blade ID.
| ||||
| CserviceDataBladeExists | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blade specified exists or not.
| ||||
| CserviceDataBladePowerState | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blade specified is powered on or not. If the AMM is experiencing a communication problem with the blade, the state may be returned as unknown(255)
| ||||
| CserviceDataBladeName | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the blade as a string. | ||||
| CserviceDataBladeCapability | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.6 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Indicates whether the blade has the capability to trigger service data. NOTE: This Mib object is deprecated and no longer supported. Please see serviceDataBladeCapabilityMask OID | ||||
| CserviceDataDumpInitiate | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.7 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Initiates a type of dump collection to be initiated for the blade. NOTE: Not all blades support this, please check serviceDataDumpCapabilityMask OID to see if the action is supported on this blade. Only one file can be moved to the'/service' directory at a time, please look over fileManagement OID to check if the file has been compeleted. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CserviceDataDumpRetrieve | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.8 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Retrieve a type of service data file from blade to AMM. NOTE: This OID only is valid for the last four bit mask designations listed in the serviceDataDumpCapabilityMask OID. Only one file can be moved to the '/service' directory at a time, please look over fileManagement OID to check if the file has been compeleted. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| CserviceDataDumpCapabilityMask | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates whether the blade has the capability to trigger service data and if so, which operations are supported and whether the file can be transferred to the AMM from the blade. The values and meanings are as follows: 0000 0000 means this blade does not support any at all. 0000 0001 means this blade supports 'processor' type and the file remains on the blade. 0000 0010 means this blade supports 'platform' type and the file remains on the blade 0000 0100 means this blade supports 'partition' type and the file remians on the blade 0000 1000 means this blade supports 'processor' type and the file can be transferred to the AMM. 0001 0000 means this blade supports 'platform' type and the file can be transferred to the AMM. 0010 0000 means this blade supports 'partition' type and the file can be transferred to the AMM 0100 0000 means this blade supports 'serviceData' type and the file can be transferred to the AMM For example, the returned value of 01111000 means this blade supports 'processor','platform', 'partition' and 'serviceData' types, and the file can be transferred to the AMM | ||||
| CserviceDataDumpInProgress | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory An indicator as to whether a blade dump is in progress for the specified blade. This object ONLY applies to dumps that can be triggered by the AMM and where the dump file is transferred to the AMM filesystem upon completion. See the serviceDataDumpCapabilityMask object for support levels. The flag that this MIB object represents will be set on when the IPMI command is sent to the blade indicating 'init dump' and will be cleared upon receiving the valid dump file from the blade or the creation of the text file indicating the problem encountered. If it cannot be determined if the dump is in progress, the unknown(255) value is returned.
| ||||
| NbladeSystemReferenceCodes | 1.3.6.1.4.1.2.3.51.2.23.3.3 | |||
| TbladeSysRefCodesTable | 1.3.6.1.4.1.2.3.51.2.23.3.3.1 | NA | mandatory | |
table · not-accessible · mandatory Table of blade system reference codes. | ||||
| RbladeSysRefCodesEntry | 1.3.6.1.4.1.2.3.51.2.23.3.3.1.1 | NA | mandatory | |
| CsysRefCodeIndex | 1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory System reference codes index. | ||||
| CsysRefCodeBayNumber | 1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The bay number of the blade which has the system reference code. | ||||
| CsysRefCodeSequence | 1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the blade specified exists or not. | ||||
| CsysRefCode | 1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.4 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Unique ID and system reference code for the blade. | ||||
| CsysRefCodeTimestamp | 1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Timestamp of system reference code for the blade. | ||||
| TbladeSysRefCodesDetailsTable | 1.3.6.1.4.1.2.3.51.2.23.3.3.2 | NA | mandatory | |
table · not-accessible · mandatory Table of details of blade system reference codes. | ||||
| RbladeSysRefCodesDetailsEntry | 1.3.6.1.4.1.2.3.51.2.23.3.3.2.1 | NA | mandatory | |
| CsysRefCodeDetailIndex | 1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory System reference codes index. | ||||
| CsysRefCodeDetailBayNumber | 1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The bay number of the blade which has the details of system reference code. | ||||
| CsysRefCodeDetailSRCSequence | 1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory A sequence of the system reference codes for the blade. | ||||
| CsysRefCodeDetailSequence | 1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.4 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory A sequence of the detailed information of the system reference codes for the blade. | ||||
| CsysRefCodeDetailDataString | 1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.5 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Detailed information of the system reference codes for the blade. | ||||
| NserviceAdvisor | 1.3.6.1.4.1.2.3.51.2.23.4 | |||
| NautoCallHomeSetup | 1.3.6.1.4.1.2.3.51.2.23.4.1 | |||
| SacceptLicenseAgreement | 1.3.6.1.4.1.2.3.51.2.23.4.1.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Accept Terms and Conditions of AMM Service Advisor. The user will have to accept the terms and conditions before Service Advisor can send diagnostic data to IBM support personnel. If AMM configuration is reset to defaults, the user will have to accept the terms and conditions again before they can enable Service Advisor. For more information, please refer to the IBM BladeCenter User's Guide. A GET of this object may return disabled(0) or enabled(1), depending upon the current state. However, only enabled(1) is accepted on a SET in order to accept the license agreement. A SET of disabled(0) will return noSuchValue and is not allowed.
| ||||
| SserviceAdvisorEnable | 1.3.6.1.4.1.2.3.51.2.23.4.1.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable IBM Support. The User Agreement must be accepted and the contact information must be set before the IBM Support function of Service Advisor can be enabled.
| ||||
| NserviceSupportCenter | 1.3.6.1.4.1.2.3.51.2.23.4.2 | |||
| SibmSupportCenter | 1.3.6.1.4.1.2.3.51.2.23.4.2.1 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory The country code for the IBM Support Center. 2 character ISO country code. | ||||
| NcontactInformation | 1.3.6.1.4.1.2.3.51.2.23.4.3 | |||
| ScompanyName | 1.3.6.1.4.1.2.3.51.2.23.4.3.1 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory The organization/company name of the contact person. 1-30 characters. | ||||
| ScontactName | 1.3.6.1.4.1.2.3.51.2.23.4.3.2 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory The name of the contact person.1-30 characters. | ||||
| SphoneNumber | 1.3.6.1.4.1.2.3.51.2.23.4.3.3 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory The phone of the contact person. 5-30 characters. | ||||
| SemailAddress | 1.3.6.1.4.1.2.3.51.2.23.4.3.4 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory The email of the contact person. It must contain '@' and dot '.' in form userid@hostname (50 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters. | ||||
| Saddress | 1.3.6.1.4.1.2.3.51.2.23.4.3.5 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory The address of the machine location. The information in this field should be of sufficient detail to allow someone to quickly find the chassis when necessary. 1-30 characters. | ||||
| Scity | 1.3.6.1.4.1.2.3.51.2.23.4.3.6 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory The city of the machine location. 1-30 characters. | ||||
| Sstate | 1.3.6.1.4.1.2.3.51.2.23.4.3.7 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory The state of the machine location. 2-3 characters. | ||||
| SpostalCode | 1.3.6.1.4.1.2.3.51.2.23.4.3.8 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory The postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid. | ||||
| SphoneNumberExt | 1.3.6.1.4.1.2.3.51.2.23.4.3.10 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory The extension of the phone. 30 characters maximum. | ||||
| SaltContactName | 1.3.6.1.4.1.2.3.51.2.23.4.3.11 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory (Optional) The name of the alternate contact person.1-30 characters. | ||||
| SaltPhoneNumber | 1.3.6.1.4.1.2.3.51.2.23.4.3.12 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory (Optional) The phone of the alternate contact person. 5-30 characters. | ||||
| SaltPhoneNumberExt | 1.3.6.1.4.1.2.3.51.2.23.4.3.13 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory (Optional) The extension of the alternate phone. 30 characters maximum. | ||||
| SaltEmailAddress | 1.3.6.1.4.1.2.3.51.2.23.4.3.14 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory (Optional) The email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (50 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters. | ||||
| SmachineLocPhone | 1.3.6.1.4.1.2.3.51.2.23.4.3.15 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory (Optional) The contact phone number of the machine location. 5-30 characters. | ||||
| NhttpProxyConfig | 1.3.6.1.4.1.2.3.51.2.23.4.4 | |||
| ShttpProxyEnable | 1.3.6.1.4.1.2.3.51.2.23.4.4.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Disable/Enable of the HTTP Proxy. Select Enable to use the proxy for call home connections from the AMM to IBM. HTTP Proxy is used by the AMM when it is not connected to the internet directly.
| ||||
| ShttpProxyLocation | 1.3.6.1.4.1.2.3.51.2.23.4.4.2 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Fully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters. | ||||
| ShttpProxyPort | 1.3.6.1.4.1.2.3.51.2.23.4.4.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory The port number of the HTTP Proxy. An integer value from 1 to 65535. | ||||
| ShttpProxyUserName | 1.3.6.1.4.1.2.3.51.2.23.4.4.4 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory User Name of the HTTP Proxy. A maximum of 30 characters string without spaces. | ||||
| ShttpProxyPassword | 1.3.6.1.4.1.2.3.51.2.23.4.4.5 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Password of the HTTP Proxy. A maximum of 15 characters string without spaces. | ||||
| NactivityLogs | 1.3.6.1.4.1.2.3.51.2.23.4.5 | |||
| TactivityLogTable | 1.3.6.1.4.1.2.3.51.2.23.4.5.1 | NA | mandatory | |
table · not-accessible · mandatory Table of Service Advisor Activity Log entries information. This table displays the last five events that were generated by the system or user that are called home. The entries are displayed in reverse chronological order (most recent call home entry first). For any events that happen with same Date/Time, only one event will be called home. If a call home event that is already in the activity log is triggered again on the same event source, it will not be called home again unless the prior entry has been acknowledged as corrected or 120 hours (5 days) have passed since it initially occurred and was called home. | ||||
| RactivityLogEntry | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1 | NA | mandatory | |
row · not-accessible · mandatory Activity Log table entry. Each entry has the result of the call-home attempt, the service number assigned for the issue by IBM support, the event ID, event source, date and time that event occured, and a text message.
| ||||
| CactivityLogIndex | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The Activity Log index number. For consistent results, view as a table and not as individual entries. | ||||
| CactivityLogString | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A string of data detailing one Activity Log entry. The text message is from the original entry in the event log. For consistent results, view as a table and not as individual entries. | ||||
| CactivityLogAcknowledge | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to certain events to indicate their awareness of the issue. Checking the acknowledge flag will not cause the event to be removed from the log or close the ticket at IBM support. This log is not cleared, so the acknowledge flag can be used to indicate a problem can be ignored. This field can be also used to override the 120 hour (5 day) filtering of reports via IBM Support or FTP/TFTP Server of Service Data. For consistent results, view as a table and not as individual entries.
| ||||
| CactivityLogAttribute | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.4 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory A string of data detailing one Activity Log entry's attribute. It contains states of both calling IBM support and FTP/TFTP Server. A PENDING indicates that the system is preparing for the event to be called home by collecting data about the systems state. A SUCCESS state indicates that the problem was successfully transmitted to IBM support or FTP/TFTP Server. A DISABLED state indicates that Service Advisor has disabled calling IBM Support or FTP/TFTP Server while the hardware event is detected. A NOT SENT state indicates that the serviceable event was not sent to prevent the same event from being sent repeatedly. The FAILED state indicates that the attempt to transmit the event information was not successful. Additional information may be found in the Event Log. The service number is similar to a ticket number that can be used as a reference to the issue reported by the machine when contacting IBM support. The event ID, event source, date and time are all information from the original entry in the event log. The acknowledged as corrected field is a reminder to certain events to indicate their awareness of the issue. For consistent results, view as a table and not as individual entries. | ||||
| NautoFTPSetup | 1.3.6.1.4.1.2.3.51.2.23.5 | |||
| SautoFTPCallMode | 1.3.6.1.4.1.2.3.51.2.23.5.1 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory This field specifies the automated problem reporting mode. Automated problem reporting mode allows the AMM to automatically put service data to a specified server when a call home event is detected. For any call home events that happen with same Date/Time, only one event will be reported. The system will also wait for an interval of 120 hours (5 days) before another identical event can be sent for the same failed component.
| ||||
| SautoFTPCallAddr | 1.3.6.1.4.1.2.3.51.2.23.5.2 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory This field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address. | ||||
| SautoFTPCallPort | 1.3.6.1.4.1.2.3.51.2.23.5.3 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory This field specifies the port on remote FTP/TFTP server for data transmission. | ||||
| SautoFTPCallUserID | 1.3.6.1.4.1.2.3.51.2.23.5.4 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory This field specifies the user account to login remote FTP server. | ||||
| SautoFTPCallPassword | 1.3.6.1.4.1.2.3.51.2.23.5.5 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory This field specifies the password to login remote FTP server. | ||||
| NcallHomeExclusionEvents | 1.3.6.1.4.1.2.3.51.2.23.6 | |||
| TreadCallHomeExclusionEventTable | 1.3.6.1.4.1.2.3.51.2.23.6.1 | NA | mandatory | |
table · not-accessible · mandatory Table of Call Home Exclusion Event entries information. | ||||
| RreadCallHomeExclusionEventEntry | 1.3.6.1.4.1.2.3.51.2.23.6.1.1 | NA | mandatory | |
row · not-accessible · mandatory Call Home Exclusion Event table entry | ||||
| CreadCallHomeExclusionEventIndex | 1.3.6.1.4.1.2.3.51.2.23.6.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The index number of one Call Home Exclusion Event. For consistent results, view as a table and not as individual entries. | ||||
| CreadCallHomeExclusionEventID | 1.3.6.1.4.1.2.3.51.2.23.6.1.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The Event ID of one Call Home Exclusion Event entry. For consistent results, view as a table and not as individual entries. | ||||
| SaddCallHomeExclusionEvent | 1.3.6.1.4.1.2.3.51.2.23.6.2 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Add one call home Event ID into the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. If Service Advisor Terms and Conditions are accepted, an event can be added into the exclusion list. NOTE: Value returned for the GET command is meaningless for this MIB object. | ||||
| SrmCallHomeExclusionEvent | 1.3.6.1.4.1.2.3.51.2.23.6.3 | OCTET STRING | RW | mandatory |
scalar · OCTET STRING · read-write · mandatory Remove one call home Event ID from the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. If Service Advisor Terms and Conditions are accepted, an event on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object. | ||||
| SrmAllCallHomeExclusionEvent | 1.3.6.1.4.1.2.3.51.2.23.6.4 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Remove all Event IDs from the Call Home Exclusion List. If Service Advisor Terms and Conditions are accepted, events on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object.
| ||||
| Nscaling | 1.3.6.1.4.1.2.3.51.2.24 | |||
| TscalableComplexTable | 1.3.6.1.4.1.2.3.51.2.24.1 | NA | mandatory | |
table · not-accessible · mandatory Table of scalable complex information. This table provides information and control actions related to the scalable complexes installed in the chassis. Partition, node and port information and control are defined in their own tables. | ||||
| RscalableComplexEntry | 1.3.6.1.4.1.2.3.51.2.24.1.1 | NA | mandatory | |
| CscalableComplexIdentifier | 1.3.6.1.4.1.2.3.51.2.24.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The unique numeric identifier for a complex installed in the chassis. | ||||
| CscalableComplexNumPartitions | 1.3.6.1.4.1.2.3.51.2.24.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The number of partitions currently defined for this complex. | ||||
| CscalableComplexNumNodes | 1.3.6.1.4.1.2.3.51.2.24.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The number of nodes existing in this complex, regardless of their assignment to any given partition. The physical slot location of the nodes can be determined from the scalableComplexNodeTable. | ||||
| CscalableComplexPartStartSlot | 1.3.6.1.4.1.2.3.51.2.24.1.1.4 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The lowest slot number occupied by the nodes in the new partition that is being created via the scalableComplexAction=create(3) action. This object must be set prior to triggering the partition creation. | ||||
| CscalableComplexPartNumNodes | 1.3.6.1.4.1.2.3.51.2.24.1.1.5 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The number of nodes to be included in the new partition that is being created via the scalableComplexAction=create(3) action. This object must be set prior to triggering the partition creation. | ||||
| CscalableComplexAction | 1.3.6.1.4.1.2.3.51.2.24.1.1.6 | INTEGER | WO | mandatory |
column · INTEGER · write-only · mandatory This object allows various actions to be taken in relation to a particular complex.
clear(1) - This clears all partition information related to the complex. Any nodes
associated with the complex are no longer assigned to any partitions.
All nodes in the complex must be powered off prior to attempting this
operation, otherwise, the action will fail.
autocreate(2) - This creates a single partition which includes all nodes associated
with the complex. Any other prior partition definitions must be
deleted prior to issuing this action, otherwise, the action will fail.
create(3) - This allows the creation of a partition within the complex. Prior to
triggering this action, the scalableComplexPartStartSlot and
scalableComplexPartNumNodes objects must be set first to identify the starting
slot number and number of nodes to be included in this new partition.
The nodes chosen for inclusion in this new partition must not be part of
another existing partition, otherwise, the action will fail.
| ||||
| TscalableComplexPartitionTable | 1.3.6.1.4.1.2.3.51.2.24.2 | NA | mandatory | |
table · not-accessible · mandatory Table of scalable complex partition information. This table provides information and control actions related to the partitions defined across all of the complexes installed in the chassis. Complex, node and port information and control are defined in their own tables. | ||||
| RscalableComplexPartitionEntry | 1.3.6.1.4.1.2.3.51.2.24.2.1 | NA | mandatory | |
row · not-accessible · mandatory Scalable complex partition information. | ||||
| CscalableComplexId | 1.3.6.1.4.1.2.3.51.2.24.2.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The unique numeric identifier for a complex installed in the chassis. | ||||
| CscalableComplexPartitionIdentifier | 1.3.6.1.4.1.2.3.51.2.24.2.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The unique numeric identifier for a partition defined within a complex installed in the chassis. | ||||
| CscalableComplexPartitionMode | 1.3.6.1.4.1.2.3.51.2.24.2.1.3 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory The currently configured mode of this partition. It is recommended that a partition be powered off prior to modification of the mode. In addition, switching a partition mode to stand-alone will cause subsequent partition actions to be ignored until the partition mode is restored.
| ||||
| CscalableComplexPartitionNumNodes | 1.3.6.1.4.1.2.3.51.2.24.2.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The number of nodes currently defined for this partition. | ||||
| CscalableComplexPartitionStatus | 1.3.6.1.4.1.2.3.51.2.24.2.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current power status of this partition when the partition has a valid partition configuration. However, in the event the partition reports a partition consitency check problem, the invalid state is provided.
| ||||
| CscalableComplexPartitionAction | 1.3.6.1.4.1.2.3.51.2.24.2.1.6 | INTEGER | WO | mandatory |
column · INTEGER · write-only · mandatory This object allows various actions to be taken in relation to a particular partition
in a given complex.
delete(1) - Deletes the partition from the complex. All nodes in the partition must
be powered off prior to attempting this operation, otherwise, the action
will fail.
poweron(2) - Powers up a powered off partition
poweroff(3) - Powers off an already powered on partition
powercycle(4) - Power cycles a partition
| ||||
| TscalableComplexNodeTable | 1.3.6.1.4.1.2.3.51.2.24.3 | NA | mandatory | |
table · not-accessible · mandatory Table of scalable complex node information. This table provides information and control actions related to the nodes installed in the chassis. Complex, partition and port information and control are defined in their own tables. | ||||
| RscalableComplexNodeEntry | 1.3.6.1.4.1.2.3.51.2.24.3.1 | NA | mandatory | |
| CscalableComplexNodeSlot | 1.3.6.1.4.1.2.3.51.2.24.3.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The base slot number where the node exists in the chassis. | ||||
| CscalableComplexNodeName | 1.3.6.1.4.1.2.3.51.2.24.3.1.2 | OCTET STRING (SIZE (256)) | RO | mandatory |
column · OCTET STRING (SIZE (256)) · read-only · mandatory The description string which uniquely identifies the blade. | ||||
| CscalableComplexNodeType | 1.3.6.1.4.1.2.3.51.2.24.3.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The general categorization of the node.
| ||||
| CscalableComplexNodeResources | 1.3.6.1.4.1.2.3.51.2.24.3.1.4 | OCTET STRING (SIZE (256)) | RO | mandatory |
column · OCTET STRING (SIZE (256)) · read-only · mandatory A string providing a summary overview of the resources provided by this node. | ||||
| CscalableComplexNodeRole | 1.3.6.1.4.1.2.3.51.2.24.3.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if the node is assigned to a partition, and if so, provides an indication of whether the node is the primary node of the partition or not.
| ||||
| CscalableComplexNodeState | 1.3.6.1.4.1.2.3.51.2.24.3.1.6 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The physical power state of this node.
| ||||
| CscalableComplexNodeUUID | 1.3.6.1.4.1.2.3.51.2.24.3.1.7 | OCTET STRING (SIZE (256)) | RO | mandatory |
column · OCTET STRING (SIZE (256)) · read-only · mandatory The Universally Unique IDentifier (UUID) of this node, represented as a 16 byte hex number. | ||||
| CscalableComplexNodeSerialNum | 1.3.6.1.4.1.2.3.51.2.24.3.1.8 | OCTET STRING (SIZE (256)) | RO | mandatory |
column · OCTET STRING (SIZE (256)) · read-only · mandatory The serial number of this node. | ||||
| CscalableComplexNodeNumPorts | 1.3.6.1.4.1.2.3.51.2.24.3.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The number of remote nodes that this node has links to. | ||||
| CscalableComplexNodeComplexID | 1.3.6.1.4.1.2.3.51.2.24.3.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory For an assigned node, the identifier of the complex this node is related to. For an unassigned node, this object has no meaning. | ||||
| CscalableComplexNodePartitionID | 1.3.6.1.4.1.2.3.51.2.24.3.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory For an assigned node, the identifier of the partition this node is related to. For an unassigned node, this object has no meaning. | ||||
| CscalableComplexNodeLogicalID | 1.3.6.1.4.1.2.3.51.2.24.3.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The unique numeric identifier for this node, unique within the partition. | ||||
| CscalableComplexNodeAction | 1.3.6.1.4.1.2.3.51.2.24.3.1.14 | INTEGER | WO | mandatory |
column · INTEGER · write-only · mandatory The actions that can be applied to an unassigned node. The current state is provided by the scalableComplexNodeState object.
| ||||
| TscalableComplexNodePortTable | 1.3.6.1.4.1.2.3.51.2.24.4 | NA | mandatory | |
table · not-accessible · mandatory Table of scalable complex node port information which provides details related to the port connectivity. Complex, partition and node information and control are defined in their own tables. | ||||
| RscalableComplexNodePortEntry | 1.3.6.1.4.1.2.3.51.2.24.4.1 | NA | mandatory | |
row · not-accessible · mandatory Scalable complex node port information. | ||||
| CscalableComplexNodePortSlot | 1.3.6.1.4.1.2.3.51.2.24.4.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The base slot number where the node exists in the chassis. | ||||
| CscalableComplexNodePortNum | 1.3.6.1.4.1.2.3.51.2.24.4.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The port number of a port on this node. Note that this port number is 0-based, but since it is used as the table index (0 is not allowed), it will be presented as one more than the actual port number. | ||||
| CscalableComplexNodePortRemChkSum | 1.3.6.1.4.1.2.3.51.2.24.4.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The checksum of the remote port, used as a port identifier. | ||||
| CscalableComplexNodePortRemNum | 1.3.6.1.4.1.2.3.51.2.24.4.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The zero-based port number of the remote port. | ||||
| CscalableComplexNodePortStatus | 1.3.6.1.4.1.2.3.51.2.24.4.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current status of the port.
| ||||
| CscalableComplexNodePortType | 1.3.6.1.4.1.2.3.51.2.24.4.1.6 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The port type.
| ||||
Textual conventions
InetAddressIPv6OCTET STRING (SIZE (16))Display hint:
2x:2x:2x:2x:2x:2x:2x:2xRepresents an IPv6 network address. Since MIB browsers may require different formats, the address is expected to be the 16 byte address in network-byte order, and shortened formats such as 0::0 are not accepted in SET operations. Two common examples are: The NetSNMP command line will accept SET requests like: snmpset -v1 -cprivate <host> s 2001:00:00:00:FFFF:CCC4:BBB2:AAA6 Other MIB browsers may require the SET request value to be formatted as: # 0x20 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0xFF 0xFF 0xCC 0xC4 0xBB 0xB2 0xAA 0xA6