OPTIX-NE-MIB
HUAWEI Technology Co.,LtdThis mib specifies NE information
snmptranslate -m OPTIX-NE-MIB -Tpsnmpwalk -v2c -c <community> -m OPTIX-NE-MIB <host> 1.3.6.1.4.1.2011.2.25.4.30.21Imports
| OPTIX-OID-MIB | optixProvisionEqpt |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IoptixNe | 1.3.6.1.4.1.2011.2.25.4.30.21 | ||||||||||||
identity This mib specifies NE information | |||||||||||||
| NoptixNeGroup | 1.3.6.1.4.1.2011.2.25.4.30.21.1 | ||||||||||||
| SoptixNeName | 1.3.6.1.4.1.2011.2.25.4.30.21.1.1 | OCTET STRING (SIZE (0..64)) | RW | ID125-xxxx | |||||||||
scalar · OCTET STRING (SIZE (0..64)) · read-write · current This object indicates the NE name. Example values from LibreNMS test devices
| |||||||||||||
| SoptixNePosition | 1.3.6.1.4.1.2011.2.25.4.30.21.1.2 | OCTET STRING (SIZE (0..32)) | RW | ||||||||||
scalar · OCTET STRING (SIZE (0..32)) · read-write · current This object indicates the NE position. | |||||||||||||
| SoptixNeMemo | 1.3.6.1.4.1.2011.2.25.4.30.21.1.3 | OCTET STRING (SIZE (0..32)) | RW | ||||||||||
scalar · OCTET STRING (SIZE (0..32)) · read-write · current This object indicates the note of the NE. | |||||||||||||
| SoptixNeH4mode | 1.3.6.1.4.1.2011.2.25.4.30.21.1.4 | Unsigned32 | RW | ||||||||||
scalar · Unsigned32 · read-write · current This object indicates the H4 mode. Values of the higher six bits of an H4 byte: 0: all 0s, 1: all 1s. The default value is 0. | |||||||||||||
| SoptixNeDbBackupDelay | 1.3.6.1.4.1.2011.2.25.4.30.21.1.5 | Unsigned32 | RW | ||||||||||
scalar · Unsigned32 · read-write · current This object indicates the datbase backup delay time. Value range: 5 to 1440 (unit: minute) | |||||||||||||
| SoptixNeInsertmode | 1.3.6.1.4.1.2011.2.25.4.30.21.1.6 | INTEGER | RW | ||||||||||
scalar · INTEGER · read-write · current This object indicates the insertion mode of the service channel. 0: uneq, 1: ais
| |||||||||||||
| SoptixNeState | 1.3.6.1.4.1.2011.2.25.4.30.21.1.7 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object indicates the NE status. 0: install, 1: running
| |||||||||||||
| SoptixNeDeviceType | 1.3.6.1.4.1.2011.2.25.4.30.21.1.8 | INTEGER | RW | optixrtn905(95) | |||||||||
scalar · INTEGER · read-write · current This object indicates the device type. 76: Optix RTN 910, 77: Optix RTN 950, 83: Optix RTN 980,92:Optix RTN 310, 95: Optix RTN 905, 114: Optix RTN 950A, 115: OptiXRTN380, 140: OptiXRTN980L, 151: Optix RTN320, 138: Optix RTN360, 160: Optix RTN380H, 183:optixrtn905e, 152:optixrtn910a, 180:optixrtn380e, 191:PowerCube 500
Example values from LibreNMS test devices
| |||||||||||||
| SoptixNeShelfType | 1.3.6.1.4.1.2011.2.25.4.30.21.1.9 | INTEGER | RW | ||||||||||
scalar · INTEGER · read-write · current This object indicates the subrack type. 1: subracki1A, 2: subrackii2A, 3: subracki1C, 4: subracki1E, 5: subrackii2E, 146: standard310320360380380H910, 148: standard950950A, 150: standard980, 163: standardOutdoor, 167: split310320, 175: standard910A, 177: standardIndoor, 184: subracki
| |||||||||||||
| SoptixNeAutoLoad | 1.3.6.1.4.1.2011.2.25.4.30.21.1.10 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object indicates the auto load status. 0: disable, 1: enable
| |||||||||||||
| SoptixNeOdcDeviceType | 1.3.6.1.4.1.2011.2.25.4.30.21.1.11 | INTEGER | RW | ||||||||||
scalar · INTEGER · read-write · current This object indicates the ODC devicetype. 0: null, 1: apm30Ac, 2: apm30Dc, 3: ombAc, 4: ombDc
| |||||||||||||
| SoptixNeGcpNodeId | 1.3.6.1.4.1.2011.2.25.4.30.21.1.12 | IpAddress | RW | ||||||||||
scalar · IpAddress · read-write · current This object indicates the node id of gcp system. | |||||||||||||
| SoptixNeSmokeAlm | 1.3.6.1.4.1.2011.2.25.4.30.21.1.13 | INTEGER | RW | ||||||||||
scalar · INTEGER · read-write · current This object indicates the smoke alarm of the device. 1: clear, 255: invalid
| |||||||||||||
| SoptixNePnpFilePath | 1.3.6.1.4.1.2011.2.25.4.30.21.1.14 | OCTET STRING | RO | ||||||||||
scalar · OCTET STRING · read-only · current This object indicates the pnp file path and name of the device manage module. | |||||||||||||
| SoptixNe1j1status | 1.3.6.1.4.1.2011.2.25.4.30.21.1.15 | INTEGER | RW | ||||||||||
scalar · INTEGER · read-write · current This object indicates the NE 1+1 status.
| |||||||||||||
| SoptixNe1j1cfgcheck | 1.3.6.1.4.1.2011.2.25.4.30.21.1.17 | Unsigned32 | RO | ||||||||||
scalar · Unsigned32 · read-only · current This object indicates the NE 1+1 config check. | |||||||||||||
| SoptixNeInitAll | 1.3.6.1.4.1.2011.2.25.4.30.21.1.18 | INTEGER | RW | ||||||||||
scalar · INTEGER · read-write · current This object indicates that all services on the NE need to be deleted. 0: init
| |||||||||||||
| SoptixNeFeatureNum | 1.3.6.1.4.1.2011.2.25.4.30.21.1.20 | Unsigned32 | RO | ||||||||||
scalar · Unsigned32 · read-only · current This object indicates the length of the feature list. | |||||||||||||
| SoptixNeFeatureList | 1.3.6.1.4.1.2011.2.25.4.30.21.1.21 | OCTET STRING | RO | ||||||||||
scalar · OCTET STRING · read-only · current This object indicates the list of feature IDs. | |||||||||||||
| NoptixNeTableGroup | 1.3.6.1.4.1.2011.2.25.4.30.21.2 | ||||||||||||
| NoptixNe1j1ResultTrapMember | 1.3.6.1.4.1.2011.2.25.4.30.21.2.1 | ||||||||||||
| SoptixNe1j1Resultinfo | 1.3.6.1.4.1.2011.2.25.4.30.21.2.1.1 | INTEGER | AN | ||||||||||
scalar · INTEGER · accessible-for-notify · current This object indicates the NE 1+1 result.
| |||||||||||||
| ToptixNeLicenseTable | 1.3.6.1.4.1.2011.2.25.4.30.21.2.2 | NA | |||||||||||
table · not-accessible · current This table describes the device licenses. | |||||||||||||
| RoptixNeLicenseEntry | 1.3.6.1.4.1.2011.2.25.4.30.21.2.2.1 | NA | |||||||||||
row · not-accessible · current This entry describes the license of device configurations.
| |||||||||||||
| CoptixNeLicenseFuncID | 1.3.6.1.4.1.2011.2.25.4.30.21.2.2.1.1 | INTEGER | NA | ||||||||||
column · INTEGER · not-accessible · current This object indicates the license function ID.1:tpbasic,2:tpenhance,3:tpinterwork,4:sanaccess,5:sdhfee,6:pktfee,7:t32sup100g,100:snmp7500sup10g,8:flexgrid
| |||||||||||||
| CoptixNeLicenseLevel | 1.3.6.1.4.1.2011.2.25.4.30.21.2.2.1.2 | INTEGER | RW | ||||||||||
column · INTEGER · read-write · current This object indicates the function level.
| |||||||||||||
| CoptixNeLicenseState | 1.3.6.1.4.1.2011.2.25.4.30.21.2.2.1.3 | Unsigned32 | RW | ||||||||||
column · Unsigned32 · read-write · current This object indicates the license state. | |||||||||||||
| CoptixNeLicenseNum | 1.3.6.1.4.1.2011.2.25.4.30.21.2.2.1.4 | Unsigned32 | RO | ||||||||||
column · Unsigned32 · read-only · current This object indicates the number of licenses. | |||||||||||||
| NoptixNe1j1ResultTrapReport | 1.3.6.1.4.1.2011.2.25.4.30.21.2.3 | ||||||||||||
| !optixNe1j1ResultTrap | 1.3.6.1.4.1.2011.2.25.4.30.21.2.3.1 | ||||||||||||
Traps / Notifications
- optixNe1j1ResultTrap
1.3.6.1.4.1.2011.2.25.4.30.21.2.3.1