FAN-MIB
Hewlett-PackardThe MIB module is for representing switch fan entity.
snmptranslate -m FAN-MIB -Tpsnmpwalk -v2c -c <community> -m FAN-MIB <host> 1.3.6.1.4.1.11.2.14.11.5.1.54Imports
| HP-ICF-OID | hpSwitch |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Counter32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IhpicfFanMIB | 1.3.6.1.4.1.11.2.14.11.5.1.54 | ||||||||||||
identity The MIB module is for representing switch fan entity. | |||||||||||||
| NhpicfFanScalars | 1.3.6.1.4.1.11.2.14.11.5.1.54.1 | ||||||||||||
| ShpicfFanUserPrefAirflowDir | 1.3.6.1.4.1.11.2.14.11.5.1.54.1.1 | INTEGER | RW | ||||||||||
scalar · INTEGER · read-write · current The user preferred fan airflow direction. The direction could be powerToPort or portToPower. The actual fan direction has to be changed manually, this will be used to indicate to the user when when the actual fan airflow direction is different from the user preferred airflow direction.
| |||||||||||||
| NhpicfEntityFan | 1.3.6.1.4.1.11.2.14.11.5.1.54.2 | ||||||||||||
| ThpicfFanTable | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1 | NA | |||||||||||
table · not-accessible · current This table contains one row for every fan in the switch entity. | |||||||||||||
| RhpicfFanEntry | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1 | NA | |||||||||||
| ChpicfFanIndex | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.1 | HpicfDcFanIndex | NA | ||||||||||
column · HpicfDcFanIndex · not-accessible · current The index that is used to access the switch fan entry table. | |||||||||||||
| ChpicfFanTray | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.2 | Integer32 | RO | 0 | |||||||||
column · Integer32 · read-only · current The tray number in which the fan is docked. Example values from LibreNMS test devices
| |||||||||||||
| ChpicfFanType | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.3 | HpicfDcFanType | RO | 0 | |||||||||
column · HpicfDcFanType · read-only · current An indication of the vendor-specific fan. Example values from LibreNMS test devices
| |||||||||||||
| ChpicfFanState | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.4 | HpicfDcFanState | RO | 5 | |||||||||
column · HpicfDcFanState · read-only · current The current state of the fan. Example values from LibreNMS test devices
| |||||||||||||
| ChpicfFanRecovering | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.5 | Integer32 | RO | 0 | |||||||||
column · Integer32 · read-only · current An indication that the switch fan entity is faulty. Before declaring a fan to be good after a failure is detected, the same good indication must happen five (5) times in a row. A failure indication is always TRUE, while a good indication could be FALSE, hence this parameter is used to count the repeated good indications before declaring the fan to be good Example values from LibreNMS test devices
| |||||||||||||
| ChpicfFanNumFailures | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.6 | Counter32 | RO | 0 | |||||||||
column · Counter32 · read-only · current The number of times the fan has failed. Example values from LibreNMS test devices
| |||||||||||||
| ChpicfFanAirflowDirection | 1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.7 | HpicfDcFanAirflowDirection | RO | ||||||||||
column · HpicfDcFanAirflowDirection · read-only · current Indication of the fan air flow direction, either from Power supply towards the port or from the port towards the power supply. | |||||||||||||
| NhpicfFanConformance | 1.3.6.1.4.1.11.2.14.11.5.1.54.3 | ||||||||||||
| NhpicfFanCompliance | 1.3.6.1.4.1.11.2.14.11.5.1.54.3.1 | ||||||||||||
| MhpicfDcFanCompliance | 1.3.6.1.4.1.11.2.14.11.5.1.54.3.1.1 | ||||||||||||
compliance · current The compliance statement for entries which implement the FAN MIB. | |||||||||||||
| NhpicfFanGroups | 1.3.6.1.4.1.11.2.14.11.5.1.54.3.2 | ||||||||||||
| GhpicfFanScalarsGroup | 1.3.6.1.4.1.11.2.14.11.5.1.54.3.2.1 | ||||||||||||
| GhpicfFanGroup | 1.3.6.1.4.1.11.2.14.11.5.1.54.3.2.2 | ||||||||||||
group · current FAN MIB parameters | |||||||||||||
Textual conventions
HpicfDcFanAirflowDirectionINTEGERportToPower(1)powerToPort(2)An enumerated value which provides an indication of the fan airflow direction. The Physical fan airflow direction could be either from the port towards the power supply module i.e. portToPower(1), or from the power supply module towards the port i.e. powerToPort(2)
HpicfDcFanIndexUnsigned32Display hint:
dA unique value that serves as an index to identify the fan.
HpicfDcFanStateINTEGERfailed(0)maxstate(6)off(2)ok(5)overspeed(4)removed(1)underspeed(3)An enumerated value which provides an indication of the fan state.
HpicfDcFanTypeINTEGERfm(2)im(3)maxtype(6)mm(1)ps(4)rollup(5)unknown(0)An enumerated value that indications the fan types.