CPQPOWER-MIB
Compaqsnmptranslate -m CPQPOWER-MIB -Tpsnmpwalk -v2c -c <community> -m CPQPOWER-MIB <host> 1.3.6.1.4.1.232.165Imports
| CPQHOST-MIB | compaq |
|---|---|
| IF-MIB | ifDescr, ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-MIB | sysContact, sysDescr, sysLocation, sysName |
| SNMPv2-SMI | Bits, Counter32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| NcpqPower | 1.3.6.1.4.1.232.165 | ||||||||||||||||||||
| !trapCritical | 1.3.6.1.4.1.232.165.0.1 | ||||||||||||||||||||
notification A critical alarm has occurred. Action: Check the Trap Details for more information. | |||||||||||||||||||||
| !trapWarning | 1.3.6.1.4.1.232.165.0.2 | ||||||||||||||||||||
notification A warning alarm has occurred. Action: Check the Trap Details for more information. | |||||||||||||||||||||
| !trapInformation | 1.3.6.1.4.1.232.165.0.3 | ||||||||||||||||||||
notification An informational alarm has occurred. Action: Check the Trap Details for more information. | |||||||||||||||||||||
| !trapCleared | 1.3.6.1.4.1.232.165.0.4 | ||||||||||||||||||||
notification An alarm has cleared. Action: Check the Trap Details for more information. | |||||||||||||||||||||
| !trapTest | 1.3.6.1.4.1.232.165.0.5 | ||||||||||||||||||||
notification Test trap sent to a trap receiver to check proper reception of traps | |||||||||||||||||||||
| !deviceTrapInitialization | 1.3.6.1.4.1.232.165.0.6 | ||||||||||||||||||||
notification This trap is sent each time a power device is initialized.
| |||||||||||||||||||||
| NpowerDevice | 1.3.6.1.4.1.232.165.1 | ||||||||||||||||||||
| NtrapInfo | 1.3.6.1.4.1.232.165.1.1 | ||||||||||||||||||||
| StrapCode | 1.3.6.1.4.1.232.165.1.1.1 | INTEGER | RO | mandatory | 37 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory A number identifying the event for the trap that was sent. Mapped unique trap code per unique event to be used by ISEE's decoder ring. Example values from LibreNMS test devices
| |||||||||||||||||||||
| StrapDescription | 1.3.6.1.4.1.232.165.1.1.2 | DisplayString (SIZE (0..255)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · mandatory A string identifying the event for that last trap that was sent. | |||||||||||||||||||||
| StrapDeviceMgmtUrl | 1.3.6.1.4.1.232.165.1.1.3 | DisplayString (SIZE (0..255)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · mandatory A string contains the URL for the management software. | |||||||||||||||||||||
| StrapDeviceDetails | 1.3.6.1.4.1.232.165.1.1.4 | DisplayString (SIZE (0..255)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · mandatory A string details information about the UPS such as SN (serial number), PN (part number), and MN (Model Name). | |||||||||||||||||||||
| StrapDeviceName | 1.3.6.1.4.1.232.165.1.1.5 | DisplayString (SIZE (0..255)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · mandatory A string contains the name of the HP Management Module. | |||||||||||||||||||||
| NmanagementModuleIdent | 1.3.6.1.4.1.232.165.1.2 | ||||||||||||||||||||
| SdeviceManufacturer | 1.3.6.1.4.1.232.165.1.2.1 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The device's manufacturer. | |||||||||||||||||||||
| SdeviceModel | 1.3.6.1.4.1.232.165.1.2.2 | DisplayString | RO | mandatory | Assy 3.6kVA 100-240V 16A WW maPDU | ||||||||||||||||
scalar · DisplayString · read-only · mandatory The device's model. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdeviceFirmwareVersion | 1.3.6.1.4.1.232.165.1.2.3 | DisplayString | RO | mandatory | 02.00.0044 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory The device's firmware version(s). Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdeviceHardwareVersion | 1.3.6.1.4.1.232.165.1.2.4 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The device's hardware version. | |||||||||||||||||||||
| SdeviceIdentName | 1.3.6.1.4.1.232.165.1.2.5 | DisplayString | RW | mandatory | |||||||||||||||||
scalar · DisplayString · read-write · mandatory A string identifying the device. it came from sysName entered by user | |||||||||||||||||||||
| SdevicePartNumber | 1.3.6.1.4.1.232.165.1.2.6 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The device's part number. | |||||||||||||||||||||
| SdeviceSerialNumber | 1.3.6.1.4.1.232.165.1.2.7 | DisplayString | RO | mandatory | 3C87241397 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory The device's serial number. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdeviceMACAddress | 1.3.6.1.4.1.232.165.1.2.8 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The device's MAC address. | |||||||||||||||||||||
| Npdu | 1.3.6.1.4.1.232.165.2 | ||||||||||||||||||||
| NpduIdent | 1.3.6.1.4.1.232.165.2.1 | ||||||||||||||||||||
| SnumOfPdu | 1.3.6.1.4.1.232.165.2.1.1 | INTEGER (0..63) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..63) · read-only · mandatory The number of PDUs. | |||||||||||||||||||||
| TpduIdentTable | 1.3.6.1.4.1.232.165.2.1.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The Aggregate Object with number of entries equal to NumOfPdu and including the PduIdent group. | |||||||||||||||||||||
| RpduIdentEntry | 1.3.6.1.4.1.232.165.2.1.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The ident table entry containing the name, model, manufacturer, firmware version, part number, etc.
| |||||||||||||||||||||
| CpduIdentIndex | 1.3.6.1.4.1.232.165.2.1.2.1.1 | INTEGER (0..100) | RO | mandatory | 0 | ||||||||||||||||
| CpduName | 1.3.6.1.4.1.232.165.2.1.2.1.2 | DisplayString (SIZE (0..63)) | RW | mandatory | | ||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-write · mandatory The string identify the device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpduModel | 1.3.6.1.4.1.232.165.2.1.2.1.3 | DisplayString (SIZE (0..63)) | RO | mandatory | | ||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The Device Model. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpduManufacturer | 1.3.6.1.4.1.232.165.2.1.2.1.4 | DisplayString (SIZE (0..63)) | RO | mandatory | | ||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The Device Manufacturer Name (e.g. Hewlett-Packard). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpduFirmwareVersion | 1.3.6.1.4.1.232.165.2.1.2.1.5 | DisplayString (SIZE (0..63)) | RO | mandatory | | ||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The firmware revision level of the device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpduPartNumber | 1.3.6.1.4.1.232.165.2.1.2.1.6 | DisplayString (SIZE (0..63)) | RO | mandatory | | ||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The device part number. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpduSerialNumber | 1.3.6.1.4.1.232.165.2.1.2.1.7 | DisplayString (SIZE (0..63)) | RO | mandatory | | ||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The device serial number. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpduStatus | 1.3.6.1.4.1.232.165.2.1.2.1.8 | INTEGER | RO | mandatory | ok(2) | ||||||||||||||||
column · INTEGER · read-only · mandatory The overall status of the device. A value of OK(2) indicates the device is operating normally. A value of degraded(3) indicates the device is operating with warning indicators. A value of failed(4) indicates the device is operating with critical indicators.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpduControllable | 1.3.6.1.4.1.232.165.2.1.2.1.9 | INTEGER | RO | mandatory | no(2) | ||||||||||||||||
column · INTEGER · read-only · mandatory This object indicates whether or not the device is controllable.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| NpduInput | 1.3.6.1.4.1.232.165.2.2 | ||||||||||||||||||||
| TpduInputTable | 1.3.6.1.4.1.232.165.2.2.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The Aggregate Object with number of entries equal to NumOfPdu and including the PduInput group. | |||||||||||||||||||||
| RpduInputEntry | 1.3.6.1.4.1.232.165.2.2.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The input table entry containing the voltage and current for the PDU
| |||||||||||||||||||||
| CpduInputIndex | 1.3.6.1.4.1.232.165.2.2.1.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for the PduInputEntry table. | |||||||||||||||||||||
| CinputVoltage | 1.3.6.1.4.1.232.165.2.2.1.1.2 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured input voltage from the PDU meters in volts. | |||||||||||||||||||||
| CinputCurrent | 1.3.6.1.4.1.232.165.2.2.1.1.3 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured input current from the PDU meters in hundredths of Amp. | |||||||||||||||||||||
| NpduOutput | 1.3.6.1.4.1.232.165.2.3 | ||||||||||||||||||||
| TpduOutputTable | 1.3.6.1.4.1.232.165.2.3.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The Aggregate Object with number of entries equal to NumOfPdu and including the PduInput group. | |||||||||||||||||||||
| RpduOutputEntry | 1.3.6.1.4.1.232.165.2.3.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The input table entry containing the name, heat load, current load, power load, firmware, etc.
| |||||||||||||||||||||
| CpduOutputIndex | 1.3.6.1.4.1.232.165.2.3.1.1.1 | INTEGER (0..100) | RO | mandatory | 0 | ||||||||||||||||
| CpduOutputLoad | 1.3.6.1.4.1.232.165.2.3.1.1.2 | INTEGER (0..200) | RO | mandatory | 15 | ||||||||||||||||
| CpduOutputHeat | 1.3.6.1.4.1.232.165.2.3.1.1.3 | INTEGER | RO | mandatory | 5409 | ||||||||||||||||
| CpduOutputPower | 1.3.6.1.4.1.232.165.2.3.1.1.4 | INTEGER | RO | mandatory | 1587 | ||||||||||||||||
| CpduOutputNumBreakers | 1.3.6.1.4.1.232.165.2.3.1.1.5 | INTEGER | RO | mandatory | 3 | ||||||||||||||||
column · INTEGER · read-only · mandatory The number of breakers for the device. This variable indicates the number of rows in the breakers table. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TpduOutputBreakerTable | 1.3.6.1.4.1.232.165.2.3.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory List of breaker table entries. The number of entries is given by pduOutputNumBreakers . | |||||||||||||||||||||
| RpduOutputBreakerEntry | 1.3.6.1.4.1.232.165.2.3.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry containing information applicable to an breaker.
| |||||||||||||||||||||
| CbreakerIndex | 1.3.6.1.4.1.232.165.2.3.2.1.1 | INTEGER (0..100) | RO | mandatory | 1 | ||||||||||||||||
| CbreakerVoltage | 1.3.6.1.4.1.232.165.2.3.2.1.2 | INTEGER | RO | mandatory | 231 | ||||||||||||||||
| CbreakerCurrent | 1.3.6.1.4.1.232.165.2.3.2.1.3 | INTEGER | RO | mandatory | 3 | ||||||||||||||||
| CbreakerPercentLoad | 1.3.6.1.4.1.232.165.2.3.2.1.4 | INTEGER | RO | mandatory | 20 | ||||||||||||||||
| CbreakerStatus | 1.3.6.1.4.1.232.165.2.3.2.1.5 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory This object indicates the status of the breaker. A value of normal(1) indicates the breaker is operating normally. A value of overloadWarning(2) indicates the breaker has an overload warning. A value of overloadCritical(3) indicates the breaker is overloaded. A value of voltageRangeWarning(4) indicates the breaker voltage is out of tolerance by 10-20%. A value of voltageRangeCritical(5) indicates the breaker voltage is out of tolerance by more than 20%. Note: Overload status has priority over voltage tolerance status.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nups | 1.3.6.1.4.1.232.165.3 | ||||||||||||||||||||
| NupsIdent | 1.3.6.1.4.1.232.165.3.1 | ||||||||||||||||||||
| SupsIdentManufacturer | 1.3.6.1.4.1.232.165.3.1.1 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · mandatory The UPS Manufacturer Name (e.g. Hewlett-Packard). | |||||||||||||||||||||
| SupsIdentModel | 1.3.6.1.4.1.232.165.3.1.2 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory The UPS Model;Part number;Serial number (e.g. HP R5500 XR;204451-B21;B00123456W). | |||||||||||||||||||||
| SupsIdentSoftwareVersions | 1.3.6.1.4.1.232.165.3.1.3 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory The firmware revision level(s) of the UPS microcontroller(s). | |||||||||||||||||||||
| SupsIdentOemCode | 1.3.6.1.4.1.232.165.3.1.4 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..255) · read-only · mandatory A binary code indicating vendor. This should be a ?0x0c? for HP | |||||||||||||||||||||
| NupsBattery | 1.3.6.1.4.1.232.165.3.2 | ||||||||||||||||||||
| SupsBatTimeRemaining | 1.3.6.1.4.1.232.165.3.2.1 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory Battery run time in seconds before UPS turns off due to low battery. | |||||||||||||||||||||
| SupsBatVoltage | 1.3.6.1.4.1.232.165.3.2.2 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory Battery voltage as reported by the UPS meters. | |||||||||||||||||||||
| SupsBatCurrent | 1.3.6.1.4.1.232.165.3.2.3 | INTEGER (-2147483648..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (-2147483648..2147483647) · read-only · mandatory Battery Current as reported by the UPS metering. Current is positive when discharging, negative when recharging the battery. | |||||||||||||||||||||
| SupsBatCapacity | 1.3.6.1.4.1.232.165.3.2.4 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..100) · read-only · mandatory Battery percent charge. | |||||||||||||||||||||
| SupsBatteryAbmStatus | 1.3.6.1.4.1.232.165.3.2.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Gives the status of the Advanced Battery Management; batteryFloating(3) status means that the charger is temporarily charging the battery to its float voltage; batteryResting(4) is the state when the battery is fully charged and none of the other actions (charging/discharging/floating) is being done.
| |||||||||||||||||||||
| NupsInput | 1.3.6.1.4.1.232.165.3.3 | ||||||||||||||||||||
| SupsInputFrequency | 1.3.6.1.4.1.232.165.3.3.1 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The utility line frequency in tenths of Hz. | |||||||||||||||||||||
| SupsInputLineBads | 1.3.6.1.4.1.232.165.3.3.2 | Counter | RO | mandatory | |||||||||||||||||
scalar · Counter · read-only · mandatory The number of times the Input was out of tolerance in voltage or frequency. | |||||||||||||||||||||
| SupsInputNumPhases | 1.3.6.1.4.1.232.165.3.3.3 | INTEGER (0..6) | RO | mandatory | |||||||||||||||||
| TupsInputTable | 1.3.6.1.4.1.232.165.3.3.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The Aggregate Object with number of entries equal to NumPhases and including the UpsInput group. | |||||||||||||||||||||
| RupsInputEntry | 1.3.6.1.4.1.232.165.3.3.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The input table entry containing the current, voltage, etc.
| |||||||||||||||||||||
| CupsInputPhase | 1.3.6.1.4.1.232.165.3.3.4.1.1 | INTEGER (0..6) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..6) · read-only · mandatory The number of the phase. Serves as index for input table. | |||||||||||||||||||||
| CupsInputVoltage | 1.3.6.1.4.1.232.165.3.3.4.1.2 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured input voltage from the UPS meters in volts. | |||||||||||||||||||||
| CupsInputCurrent | 1.3.6.1.4.1.232.165.3.3.4.1.3 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured input current from the UPS meters in amps. | |||||||||||||||||||||
| CupsInputWatts | 1.3.6.1.4.1.232.165.3.3.4.1.4 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured input real power in watts. Most UPSs do not report this XCP data | |||||||||||||||||||||
| SupsInputSource | 1.3.6.1.4.1.232.165.3.3.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The present external source of input power. The enumeration none(2) indicates that there is no external source of power, for example, the UPS is On Battery (an internal source). The bypassFeed(4) can only be used when the Bypass source is known to be a separate utility feed than the primaryUtility(3).
| |||||||||||||||||||||
| NupsOutput | 1.3.6.1.4.1.232.165.3.4 | ||||||||||||||||||||
| SupsOutputLoad | 1.3.6.1.4.1.232.165.3.4.1 | INTEGER (0..200) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..200) · read-only · mandatory The UPS output load in percent of rated capacity. | |||||||||||||||||||||
| SupsOutputFrequency | 1.3.6.1.4.1.232.165.3.4.2 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The measured UPS output frequency in tenths of Hz. | |||||||||||||||||||||
| SupsOutputNumPhases | 1.3.6.1.4.1.232.165.3.4.3 | INTEGER (0..6) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..6) · read-only · mandatory The number of metered output phases, serves as the table index. | |||||||||||||||||||||
| TupsOutputTable | 1.3.6.1.4.1.232.165.3.4.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The Aggregate Object with number of entries equal to NumPhases and including the UpsOutput group. | |||||||||||||||||||||
| RupsOutputEntry | 1.3.6.1.4.1.232.165.3.4.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Output Table Entry containing voltage, current, etc.
| |||||||||||||||||||||
| CupsOutputPhase | 1.3.6.1.4.1.232.165.3.4.4.1.1 | INTEGER (0..6) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..6) · read-only · mandatory The number {1..3} of the output phase. | |||||||||||||||||||||
| CupsOutputVoltage | 1.3.6.1.4.1.232.165.3.4.4.1.2 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured output voltage from the UPS metering in volts. | |||||||||||||||||||||
| CupsOutputCurrent | 1.3.6.1.4.1.232.165.3.4.4.1.3 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured UPS output current in amps. | |||||||||||||||||||||
| CupsOutputWatts | 1.3.6.1.4.1.232.165.3.4.4.1.4 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured real output power in watts. | |||||||||||||||||||||
| SupsOutputSource | 1.3.6.1.4.1.232.165.3.4.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||||||||||
| NupsBypass | 1.3.6.1.4.1.232.165.3.5 | ||||||||||||||||||||
| SupsBypassFrequency | 1.3.6.1.4.1.232.165.3.5.1 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The bypass frequency in tenths of Hz. | |||||||||||||||||||||
| SupsBypassNumPhases | 1.3.6.1.4.1.232.165.3.5.2 | INTEGER (0..6) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..6) · read-only · mandatory The number of lines in the UPS bypass table. | |||||||||||||||||||||
| TupsBypassTable | 1.3.6.1.4.1.232.165.3.5.3 | NA | mandatory | ||||||||||||||||||
| RupsBypassEntry | 1.3.6.1.4.1.232.165.3.5.3.1 | NA | mandatory | ||||||||||||||||||
| CupsBypassPhase | 1.3.6.1.4.1.232.165.3.5.3.1.1 | INTEGER (0..6) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..6) · read-only · mandatory The Bypass Phase, index for the table. | |||||||||||||||||||||
| CupsBypassVoltage | 1.3.6.1.4.1.232.165.3.5.3.1.2 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured UPS bypass voltage in volts. | |||||||||||||||||||||
| NupsEnvironment | 1.3.6.1.4.1.232.165.3.6 | ||||||||||||||||||||
| SupsEnvAmbientTemp | 1.3.6.1.4.1.232.165.3.6.1 | INTEGER (-100..200) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (-100..200) · read-only · mandatory The reading of the ambient temperature in the vicinity of the UPS or SNMP agent. | |||||||||||||||||||||
| SupsEnvAmbientLowerLimit | 1.3.6.1.4.1.232.165.3.6.2 | INTEGER (-100..200) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (-100..200) · read-write · mandatory The Lower Limit of the ambient temperature; if UpsEnvAmbientTemp falls below this value, the UpsAmbientTempBad alarm will occur. | |||||||||||||||||||||
| SupsEnvAmbientUpperLimit | 1.3.6.1.4.1.232.165.3.6.3 | INTEGER (-100..200) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (-100..200) · read-write · mandatory The Upper Limit of the ambient temperature; if UpsEnvAmbientTemp rises above this value, the UpsAmbientTempBad alarm will occur. This value should be greater than UpsEnvAmbientLowerLimit. | |||||||||||||||||||||
| SupsEnvAmbientHumidity | 1.3.6.1.4.1.232.165.3.6.4 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..100) · read-only · mandatory The reading of the ambient humidity in the vicinity of the UPS or SNMP agent. | |||||||||||||||||||||
| SupsEnvRemoteTemp | 1.3.6.1.4.1.232.165.3.6.5 | INTEGER (-100..200) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (-100..200) · read-only · mandatory The reading of a remote temperature sensor connected to the UPS or SNMP agent. | |||||||||||||||||||||
| SupsEnvRemoteHumidity | 1.3.6.1.4.1.232.165.3.6.6 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..100) · read-only · mandatory The reading of a remote humidity sensor connected to the UPS or SNMP agent. | |||||||||||||||||||||
| SupsEnvNumContacts | 1.3.6.1.4.1.232.165.3.6.7 | INTEGER (1..1024) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..1024) · read-only · mandatory The number of Contacts in the UpsContactsTable. This object indicates the number of rows in the UpsContactsTable. | |||||||||||||||||||||
| TupsContactsTable | 1.3.6.1.4.1.232.165.3.6.8 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of Contact Sensing table entries. The number of entries is given by the value of UpsEnvNumContacts. | |||||||||||||||||||||
| RupsContactsTableEntry | 1.3.6.1.4.1.232.165.3.6.8.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular Contact input.
| |||||||||||||||||||||
| CupsContactIndex | 1.3.6.1.4.1.232.165.3.6.8.1.1 | INTEGER (1..1024) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..1024) · read-only · mandatory The Contact identifier; identical to the Contact Number. | |||||||||||||||||||||
| CupsContactType | 1.3.6.1.4.1.232.165.3.6.8.1.2 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory The normal state for this contact. The 'other' state is the Active state for generating the UpstdContactActiveNotice trap. If anyChange(3) is selected, then this trap is sent any time the contact changes to either Open or Closed. No traps are sent if the Contact is set to notUsed(4). In many cases, the configuration for Contacts may be done by other means, so this object may be read-only.
| |||||||||||||||||||||
| CupsContactState | 1.3.6.1.4.1.232.165.3.6.8.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The current state of the Contact input;
the value is based on the open/closed input state
and the setting for UpsContactType.
When entering the openWithNotice(3) and closedWithNotice(4)
states, no entries added to the UpsAlarmTable, but
the UpstdContactActiveNotice trap is sent.
| |||||||||||||||||||||
| CupsContactDescr | 1.3.6.1.4.1.232.165.3.6.8.1.4 | DisplayString (SIZE (0..63)) | RW | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-write · mandatory A label identifying the Contact. This object should be set by the administrator. | |||||||||||||||||||||
| SupsEnvRemoteTempLowerLimit | 1.3.6.1.4.1.232.165.3.6.9 | INTEGER (-100..200) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (-100..200) · read-write · mandatory The Lower Limit of the remote temperature; if UpsEnvRemoteTemp falls below this value, the UpsRemoteTempBad alarm will occur. | |||||||||||||||||||||
| SupsEnvRemoteTempUpperLimit | 1.3.6.1.4.1.232.165.3.6.10 | INTEGER (-100..200) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (-100..200) · read-write · mandatory The Upper Limit of the remote temperature; if UpsEnvRemoteTemp rises above this value, the UpsRemoteTempBad alarm will occur. This value should be greater than UpsEnvRemoteTempLowerLimit. | |||||||||||||||||||||
| SupsEnvRemoteHumidityLowerLimit | 1.3.6.1.4.1.232.165.3.6.11 | INTEGER (0..100) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (0..100) · read-write · mandatory The Lower Limit of the remote humidity reading; if UpsEnvRemoteHumidity falls below this value, the UpsRemoteHumidityBad alarm will occur. | |||||||||||||||||||||
| SupsEnvRemoteHumidityUpperLimit | 1.3.6.1.4.1.232.165.3.6.12 | INTEGER (0..100) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (0..100) · read-write · mandatory The Upper Limit of the remote humidity reading; if UpsEnvRemoteHumidity rises above this value, the UpsRemoteHumidityBad alarm will occur. This value should be greater than UpsEnvRemoteHumidityLowerLimit. | |||||||||||||||||||||
| NupsTest | 1.3.6.1.4.1.232.165.3.7 | ||||||||||||||||||||
| SupsTestBattery | 1.3.6.1.4.1.232.165.3.7.1 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Setting this variable to startTest initiates the battery test. All other set values are invalid.
| |||||||||||||||||||||
| SupsTestBatteryStatus | 1.3.6.1.4.1.232.165.3.7.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Reading this enumerated value gives an indication of the UPS Battery test status.
| |||||||||||||||||||||
| SupsTestTrap | 1.3.6.1.4.1.232.165.3.7.3 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Setting startTestTrap to 1 will initiate a TrapTest is sent out from HPMM. All other set values are invalid.
| |||||||||||||||||||||
| NupsControl | 1.3.6.1.4.1.232.165.3.8 | ||||||||||||||||||||
| SupsControlOutputOffDelay | 1.3.6.1.4.1.232.165.3.8.1 | INTEGER (0..2147483647) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-write · mandatory Setting this value to other than zero will cause the UPS output to turn off after the number of seconds. Setting it to 0 will cause an attempt to abort a pending shutdown. | |||||||||||||||||||||
| SupsControlOutputOnDelay | 1.3.6.1.4.1.232.165.3.8.2 | INTEGER (0..2147483647) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-write · mandatory Setting this value to other than zero will cause the UPS output to turn on after the number of seconds. Setting it to 0 will cause an attempt to abort a pending startup. | |||||||||||||||||||||
| SupsControlOutputOffTrapDelay | 1.3.6.1.4.1.232.165.3.8.3 | INTEGER (0..2147483647) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-write · mandatory When UpsControlOutputOffDelay reaches this value, a trap will be sent. | |||||||||||||||||||||
| SupsControlOutputOnTrapDelay | 1.3.6.1.4.1.232.165.3.8.4 | INTEGER (0..2147483647) | RW | deprecated | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-write · deprecated When UpsControlOutputOnDelay reaches this value, a UpsOutputOff trap will be sent. | |||||||||||||||||||||
| SupsControlToBypassDelay | 1.3.6.1.4.1.232.165.3.8.5 | INTEGER (0..2147483647) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-write · mandatory Setting this value to other than zero will cause the UPS output to go to Bypass after the number of seconds. If the Bypass is unavailable, this may cause the UPS to not supply power to the load. Setting it to 0 will cause an attempt to abort a pending shutdown. | |||||||||||||||||||||
| SupsLoadShedSecsWithRestart | 1.3.6.1.4.1.232.165.3.8.6 | INTEGER (0..2147483647) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-write · mandatory Setting this value will cause the UPS output to turn off
after the set number of seconds, then restart (after a UPS-defined
'down time') when the utility is again available.
Unlike UpsControlOutputOffDelay, which might or might not,
this object always maps to the XCP 0x8A Load Dump & Restart command,
so the desired shutdown and restart behavior is guaranteed to happen.
Once set, this command cannot be aborted.
This is the preferred Control object to use when performing an On
Battery OS Shutdown. | |||||||||||||||||||||
| NupsConfig | 1.3.6.1.4.1.232.165.3.9 | ||||||||||||||||||||
| SupsConfigOutputVoltage | 1.3.6.1.4.1.232.165.3.9.1 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The nominal UPS Output voltage per phase in volts. | |||||||||||||||||||||
| SupsConfigInputVoltage | 1.3.6.1.4.1.232.165.3.9.2 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The nominal UPS Input voltage per phase in volts. | |||||||||||||||||||||
| SupsConfigOutputWatts | 1.3.6.1.4.1.232.165.3.9.3 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The nominal UPS available real power output in watts. | |||||||||||||||||||||
| SupsConfigOutputFreq | 1.3.6.1.4.1.232.165.3.9.4 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The nominal output frequency in tenths of Hz. | |||||||||||||||||||||
| SupsConfigDateAndTime | 1.3.6.1.4.1.232.165.3.9.5 | DisplayString (SIZE (0..22)) | RW | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..22)) · read-write · mandatory Date and time information for the UPS. Setting this variable will initiate a set UPS date and time to this value. Reading this variable will return the UPS time and date. This value is not referenced to sysUpTime. It is simply the clock value from the UPS real time clock. Format is as follows: MM/DD/YYYY:HH:MM:SS. | |||||||||||||||||||||
| SupsConfigLowOutputVoltageLimit | 1.3.6.1.4.1.232.165.3.9.6 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The Lower limit for acceptable Output Voltage, per the UPS specifications. | |||||||||||||||||||||
| SupsConfigHighOutputVoltageLimit | 1.3.6.1.4.1.232.165.3.9.7 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The Upper limit for acceptable Output Voltage, per the UPS specifications. | |||||||||||||||||||||
| NupsRecep | 1.3.6.1.4.1.232.165.3.10 | ||||||||||||||||||||
| SupsNumReceptacles | 1.3.6.1.4.1.232.165.3.10.1 | INTEGER (0..64) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..64) · read-only · mandatory The number of independently controllable Receptacles, as described in the UpsRecepTable. | |||||||||||||||||||||
| TupsRecepTable | 1.3.6.1.4.1.232.165.3.10.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The Aggregate Object with number of entries equal to NumReceptacles and including the UpsRecep group. | |||||||||||||||||||||
| RupsRecepEntry | 1.3.6.1.4.1.232.165.3.10.2.1 | NA | mandatory | ||||||||||||||||||
| CupsRecepIndex | 1.3.6.1.4.1.232.165.3.10.2.1.1 | INTEGER (1..64) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..64) · read-only · mandatory The number of the Receptacle. Serves as index for Receptacle table. | |||||||||||||||||||||
| CupsRecepStatus | 1.3.6.1.4.1.232.165.3.10.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Recep Status 1=On/Close, 2=Off/Open, 3=On w/Pending Off, 4=Off w/Pending ON, 5=Unknown.
| |||||||||||||||||||||
| CupsRecepOffDelaySecs | 1.3.6.1.4.1.232.165.3.10.2.1.3 | INTEGER (-1..2147483647) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..2147483647) · read-write · mandatory The Delay until the Receptacle is turned Off. Setting this value to other than -1 will cause the UPS output to turn off after the number of seconds (0 is immediately). Setting it to -1 will cause an attempt to abort a pending shutdown. When this object is set while the UPS is On Battery, it is not necessary to set UpsRecepOnDelaySecs, since the outlet will turn back on automatically when power is available again. | |||||||||||||||||||||
| CupsRecepOnDelaySecs | 1.3.6.1.4.1.232.165.3.10.2.1.4 | INTEGER (-1..2147483647) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..2147483647) · read-write · mandatory The Delay until the Receptacle is turned On. Setting this value to other than -1 will cause the UPS output to turn on after the number of seconds (0 is immediately). Setting it to -1 will cause an attempt to abort a pending restart. | |||||||||||||||||||||
| CupsRecepAutoOffDelay | 1.3.6.1.4.1.232.165.3.10.2.1.5 | INTEGER (-1..32767) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..32767) · read-write · mandatory The delay after going On Battery until the Receptacle is automatically turned Off. A value of -1 means that this Output should never be turned Off automatically, but must be turned Off only by command. Values from 0 to 30 are valid, but probably innappropriate. The AutoOffDelay can be used to prioritize loads in the event of a prolonged power outage; less critical loads will turn off earlier to extend battery time for the more critical loads. If the utility power is restored before the AutoOff delay counts down to 0 on an outlet, that outlet will not turn Off. | |||||||||||||||||||||
| CupsRecepAutoOnDelay | 1.3.6.1.4.1.232.165.3.10.2.1.6 | INTEGER (-1..32767) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..32767) · read-write · mandatory Seconds delay after the Outlet is signaled to turn On before the Output is Automatically turned ON. A value of -1 means that this Output should never be turned On automatically, but only when specifically commanded to do so. A value of 0 means that the Receptacle should come On immediately at power-up or for an On command. | |||||||||||||||||||||
| CupsRecepShedSecsWithRestart | 1.3.6.1.4.1.232.165.3.10.2.1.7 | INTEGER (0..2147483647) | RW | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-write · mandatory Setting this value will cause the UPS output to turn off
after the set number of seconds, then restart (after a UPS-defined
'down time') when the utility is again available.
Unlike UpsRecepOffDelaySecs, which might or might not,
this object always maps to the XCP 0x8A Load Dump & Restart command,
so the desired shutdown and restart behavior is guaranteed to happen.
Once set, this command cannot be aborted. | |||||||||||||||||||||
| NupsTopology | 1.3.6.1.4.1.232.165.3.11 | ||||||||||||||||||||
| SupsTopologyType | 1.3.6.1.4.1.232.165.3.11.1 | INTEGER (0..32767) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..32767) · read-only · mandatory Value which denotes the type of UPS by its power topology. Values are the same as those described in the XCP Topology block's Overall Topology field. | |||||||||||||||||||||
| SupsTopoMachineCode | 1.3.6.1.4.1.232.165.3.11.2 | INTEGER (0..32767) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..32767) · read-only · mandatory ID Value which denotes the Compaq/HP model of the UPS for software. Values are the same as those described in the XCP Configuration block's Machine Code field. | |||||||||||||||||||||
| SupsTopoUnitNumber | 1.3.6.1.4.1.232.165.3.11.3 | INTEGER (0..64) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..64) · read-only · mandatory Identifies which unit and what type of data is being reported. A value of 0 means that this MIB information comes from the top-level system view (eg, manifold module or system bypass cabinet reporting total system output). Standalone units also use a value of 0, since they are the 'full system' view. A value of 1 or higher indicates the number of the module in the system which is reporting only its own data in the HP MIB objects. | |||||||||||||||||||||
| SupsTopoPowerStrategy | 1.3.6.1.4.1.232.165.3.11.4 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Value which denotes which Power Strategy is currently set for the UPS. The values are: highAlert(1) - The UPS shall optimize its operating state to maximize its power-protection levels. This mode will be held for at most 24 hours. standard(2) - Balanced, normal power protection strategy. UPS will not enter HE operating mode from this setting. enableHighEfficiency(3) - The UPS is enabled to enter HE operating mode to optimize its operating state to maximize its efficiency, when conditions change to permit it (as determined by the UPS). forceHighEfficiency(4) - If this value is permitted to be Set for this UPS, and if conditions permit, requires the UPS to enter High Efficiency mode now, without delay (for as long as utility conditions permit). After successfully set to forceHighEfficiency(4), UpsTopoPowerStrategy changes to value enableHighEfficiency(3). UpsOutputSource will indicate if the UPS status is actually operating in High Efficiency mode.
| |||||||||||||||||||||
| Npdr | 1.3.6.1.4.1.232.165.4 | ||||||||||||||||||||
| NpdrIdent | 1.3.6.1.4.1.232.165.4.1 | ||||||||||||||||||||
| SpdrName | 1.3.6.1.4.1.232.165.4.1.1 | DisplayString (SIZE (0..63)) | RW | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-write · mandatory The string identify the device. | |||||||||||||||||||||
| SpdrModel | 1.3.6.1.4.1.232.165.4.1.2 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory The Device Model. | |||||||||||||||||||||
| SpdrManufacturer | 1.3.6.1.4.1.232.165.4.1.3 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory The Device Manufacturer Name (e.g. Hewlett-Packard). | |||||||||||||||||||||
| SpdrFirmwareVersion | 1.3.6.1.4.1.232.165.4.1.4 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory The firmware revision level of the device. | |||||||||||||||||||||
| SpdrPartNumber | 1.3.6.1.4.1.232.165.4.1.5 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory The device part number. | |||||||||||||||||||||
| SpdrSerialNumber | 1.3.6.1.4.1.232.165.4.1.6 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory The PDR's serial number. | |||||||||||||||||||||
| SpdrVARating | 1.3.6.1.4.1.232.165.4.1.7 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The VA Rating of this PDR (all phases) | |||||||||||||||||||||
| SpdrNominalOutputVoltage | 1.3.6.1.4.1.232.165.4.1.8 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The nominal Output Voltage may differ from the nominal Input Voltage if the PDR has an input transformer | |||||||||||||||||||||
| SpdrNumPhases | 1.3.6.1.4.1.232.165.4.1.9 | INTEGER (1..3) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..3) · read-only · mandatory The number of phases for this PDR | |||||||||||||||||||||
| SpdrNumPanels | 1.3.6.1.4.1.232.165.4.1.10 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..100) · read-only · mandatory The number of panels or subfeeds in this PDR | |||||||||||||||||||||
| SpdrNumBreakers | 1.3.6.1.4.1.232.165.4.1.11 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..100) · read-only · mandatory The number of breakers in this PDR | |||||||||||||||||||||
| NpdrPanel | 1.3.6.1.4.1.232.165.4.2 | ||||||||||||||||||||
| TpdrPanelTable | 1.3.6.1.4.1.232.165.4.2.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to pdrNumPanels | |||||||||||||||||||||
| RpdrPanelEntry | 1.3.6.1.4.1.232.165.4.2.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The panel table entry containing all power parameters for each panel.
| |||||||||||||||||||||
| CpdrPanelIndex | 1.3.6.1.4.1.232.165.4.2.1.1.1 | INTEGER (0..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..10) · read-only · mandatory Index for the pdrPanelEntry table. | |||||||||||||||||||||
| CpdrPanelFrequency | 1.3.6.1.4.1.232.165.4.2.1.1.2 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The present frequency reading for the panel voltage. | |||||||||||||||||||||
| CpdrPanelPower | 1.3.6.1.4.1.232.165.4.2.1.1.3 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The present power of the panel. | |||||||||||||||||||||
| CpdrPanelRatedCurrent | 1.3.6.1.4.1.232.165.4.2.1.1.4 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The present rated current of the panel. | |||||||||||||||||||||
| CpdrPanelMonthlyKWH | 1.3.6.1.4.1.232.165.4.2.1.1.5 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The accumulated KWH for this panel since the beginning of this calendar month or since the last reset. | |||||||||||||||||||||
| CpdrPanelYearlyKWH | 1.3.6.1.4.1.232.165.4.2.1.1.6 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The accumulated KWH for this panel since the beginning of this calendar year or since the last reset. | |||||||||||||||||||||
| CpdrPanelTotalKWH | 1.3.6.1.4.1.232.165.4.2.1.1.7 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The accumulated KWH for this panel since it was put into service or since the last reset. | |||||||||||||||||||||
| CpdrPanelVoltageA | 1.3.6.1.4.1.232.165.4.2.1.1.8 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured panel output voltage. | |||||||||||||||||||||
| CpdrPanelVoltageB | 1.3.6.1.4.1.232.165.4.2.1.1.9 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured panel output voltage. | |||||||||||||||||||||
| CpdrPanelVoltageC | 1.3.6.1.4.1.232.165.4.2.1.1.10 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured panel output voltage. | |||||||||||||||||||||
| CpdrPanelCurrentA | 1.3.6.1.4.1.232.165.4.2.1.1.11 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured panel output current. | |||||||||||||||||||||
| CpdrPanelCurrentB | 1.3.6.1.4.1.232.165.4.2.1.1.12 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured panel output current. | |||||||||||||||||||||
| CpdrPanelCurrentC | 1.3.6.1.4.1.232.165.4.2.1.1.13 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured panel output current. | |||||||||||||||||||||
| CpdrPanelLoadA | 1.3.6.1.4.1.232.165.4.2.1.1.14 | INTEGER (0..200) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..200) · read-only · mandatory The percentage of load is the ratio of each output current to the rated output current to the panel. | |||||||||||||||||||||
| CpdrPanelLoadB | 1.3.6.1.4.1.232.165.4.2.1.1.15 | INTEGER (0..200) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..200) · read-only · mandatory The percentage of load is the ratio of each output current to the rated output current to the panel. | |||||||||||||||||||||
| CpdrPanelLoadC | 1.3.6.1.4.1.232.165.4.2.1.1.16 | INTEGER (0..200) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..200) · read-only · mandatory The percentage of load is the ratio of each output current to the rated output current to the panel. | |||||||||||||||||||||
| NpdrBreaker | 1.3.6.1.4.1.232.165.4.3 | ||||||||||||||||||||
| TpdrBreakerTable | 1.3.6.1.4.1.232.165.4.3.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory List of breaker table entries. The number of entries is given by pdrNumBreakers for this panel. | |||||||||||||||||||||
| RpdrBreakerEntry | 1.3.6.1.4.1.232.165.4.3.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular output breaker of a particular panel.
| |||||||||||||||||||||
| CpdrBreakerIndex | 1.3.6.1.4.1.232.165.4.3.1.1.1 | INTEGER (0..200) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..200) · read-only · mandatory The index of breakers. 42 breakers in each panel, arranged in odd and even columns | |||||||||||||||||||||
| CpdrBreakerPanel | 1.3.6.1.4.1.232.165.4.3.1.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The index of panel that these breakers are installed on. | |||||||||||||||||||||
| CpdrBreakerNumPosition | 1.3.6.1.4.1.232.165.4.3.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The position of this breaker in the panel, 1-phase breaker or n-m breaker for 2-phase or n-m-k breaker for 3-phase. | |||||||||||||||||||||
| CpdrBreakerNumPhases | 1.3.6.1.4.1.232.165.4.3.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The number of phase for this particular breaker. | |||||||||||||||||||||
| CpdrBreakerNumSequence | 1.3.6.1.4.1.232.165.4.3.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The sequence of this breaker. i.e. 1 for single phase 1,2 for 2-phase or 1,2,3 for 3-phase. | |||||||||||||||||||||
| CpdrBreakerRatedCurrent | 1.3.6.1.4.1.232.165.4.3.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The rated current in Amps for this particular breaker. | |||||||||||||||||||||
| CpdrBreakerMonthlyKWH | 1.3.6.1.4.1.232.165.4.3.1.1.7 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The accumulated KWH for this breaker since the beginning of this calendar month or since the last reset. | |||||||||||||||||||||
| CpdrBreakerYearlyKWH | 1.3.6.1.4.1.232.165.4.3.1.1.8 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The accumulated KWH for this breaker since the beginning of this calendar year or since the last reset. | |||||||||||||||||||||
| CpdrBreakerTotalKWH | 1.3.6.1.4.1.232.165.4.3.1.1.9 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The accumulated KWH for this breaker since it was put into service or since the last reset. | |||||||||||||||||||||
| CpdrBreakerCurrent | 1.3.6.1.4.1.232.165.4.3.1.1.10 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured output current for this breaker Current. | |||||||||||||||||||||
| CpdrBreakerCurrentPercent | 1.3.6.1.4.1.232.165.4.3.1.1.11 | INTEGER (0..200) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..200) · read-only · mandatory The ratio of output current over rated current for each breaker. | |||||||||||||||||||||
| CpdrBreakerPower | 1.3.6.1.4.1.232.165.4.3.1.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The power for this breaker in Watts. | |||||||||||||||||||||
| CpdrBreakerPercentWarning | 1.3.6.1.4.1.232.165.4.3.1.1.13 | INTEGER (0..200) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..200) · read-only · mandatory The percentage of Warning set for this breaker. | |||||||||||||||||||||
| CpdrBreakerPercentOverload | 1.3.6.1.4.1.232.165.4.3.1.1.14 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The percentage of Overload set for this breaker. | |||||||||||||||||||||
| Nmpdu | 1.3.6.1.4.1.232.165.5 | ||||||||||||||||||||
| NmpduIdent | 1.3.6.1.4.1.232.165.5.1 | ||||||||||||||||||||
| SmpduNumMPDU | 1.3.6.1.4.1.232.165.5.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of Modular PDUs (Core) detected. | |||||||||||||||||||||
| TmpduIdentTable | 1.3.6.1.4.1.232.165.5.1.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Indexed by mpduNumMPDU. So aggregate objects for each entry equal to mpduNumMPDU before go to the next entry. i.e if 4 MPDU detected, display 4 indexes, 4 Manufacturers, 4 Models..., start with 1. | |||||||||||||||||||||
| RmpduIdentEntry | 1.3.6.1.4.1.232.165.5.1.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The table entry containing the identifications of each MPDU as well as names of PDR panel, location of MPDU in a Data Center.
| |||||||||||||||||||||
| CmpduIdentIndex | 1.3.6.1.4.1.232.165.5.1.2.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for the MpduIdentEntry table. Start with 1 | |||||||||||||||||||||
| CmpduManufacturer | 1.3.6.1.4.1.232.165.5.1.2.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU manufacturer. StringLength=[21] | |||||||||||||||||||||
| CmpduModel | 1.3.6.1.4.1.232.165.5.1.2.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU model, marketing name. StringLength=[40]. | |||||||||||||||||||||
| CmpduName | 1.3.6.1.4.1.232.165.5.1.2.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU name, descriptive name or hostname. StringLength=[16]. | |||||||||||||||||||||
| CmpduFirmwareVersion | 1.3.6.1.4.1.232.165.5.1.2.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU firmware version(s). StringLength=[12]. | |||||||||||||||||||||
| CmpduHardwareVersion | 1.3.6.1.4.1.232.165.5.1.2.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU hardware version. StringLength=[8]. | |||||||||||||||||||||
| CmpduPartNumber | 1.3.6.1.4.1.232.165.5.1.2.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU part number. StringLength=[21]. | |||||||||||||||||||||
| CmpduSerialNumber | 1.3.6.1.4.1.232.165.5.1.2.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PDU external serial number. StringLength=[21]. | |||||||||||||||||||||
| CmpduUUID | 1.3.6.1.4.1.232.165.5.1.2.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PDU's UUID equals PN add SN then canonical conversion. StringLength=[37]. | |||||||||||||||||||||
| CmpduIP | 1.3.6.1.4.1.232.165.5.1.2.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PDU's assigned IP. StringLength=[16]. | |||||||||||||||||||||
| CmpduMACAddress | 1.3.6.1.4.1.232.165.5.1.2.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU MAC address. StringLength=[18]. | |||||||||||||||||||||
| CmpduControlStatus | 1.3.6.1.4.1.232.165.5.1.2.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU Control Status: master or slave units. StringLength=[31]. | |||||||||||||||||||||
| CmpduRegion | 1.3.6.1.4.1.232.165.5.1.2.1.13 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PDU's Region: NA, Intl, Japan... StringLength=[7]. | |||||||||||||||||||||
| CmpduType | 1.3.6.1.4.1.232.165.5.1.2.1.14 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PDU's Type: Delta, Wye, single, Wye+lowline. StringLength=[24]. | |||||||||||||||||||||
| CmpduPowerRating | 1.3.6.1.4.1.232.165.5.1.2.1.15 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PDU's Power Rating in KVA (Name Plate). Value is presented in 1/100 of the KVA. i.e. 1750 means 17.50 KVA | |||||||||||||||||||||
| CmpduInputRating | 1.3.6.1.4.1.232.165.5.1.2.1.16 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PDU's Input Current Rating in A (Name Plate) | |||||||||||||||||||||
| CmpduInputPlug | 1.3.6.1.4.1.232.165.5.1.2.1.17 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PDU's Input Plug: IEC60309 516P6,NEMA L15-30P... StringLength=[16]. | |||||||||||||||||||||
| CmpduNumBreakers | 1.3.6.1.4.1.232.165.5.1.2.1.18 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The number of breakers used in each MPDU (6 by default). | |||||||||||||||||||||
| CmpduNumOutlet | 1.3.6.1.4.1.232.165.5.1.2.1.19 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The number of outlets of each MPDU (6 by default). | |||||||||||||||||||||
| CmpduUHeight | 1.3.6.1.4.1.232.165.5.1.2.1.20 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The MPDU U Height 1U or 2 U (1U by default). | |||||||||||||||||||||
| CmpduRedundantStatus | 1.3.6.1.4.1.232.165.5.1.2.1.21 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Status of Core PDU in paired or not: Stand-alone or Redundant. StringLength=[12]. | |||||||||||||||||||||
| CmpduNumSmartExtBar | 1.3.6.1.4.1.232.165.5.1.2.1.22 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory total number of detected Smart Sticks connecting to each PDU. | |||||||||||||||||||||
| CmpduPanelName | 1.3.6.1.4.1.232.165.5.1.2.1.23 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Name of Panel that was entered by customer in GUI. StringLength=[50]. | |||||||||||||||||||||
| CmpduPanelBreakerName | 1.3.6.1.4.1.232.165.5.1.2.1.24 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Name of breakers or Panel Position entered by customer in GUI. StringLength=[50]. | |||||||||||||||||||||
| CmpduPanelBreakerRating | 1.3.6.1.4.1.232.165.5.1.2.1.25 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Breaker rating of the PDR Panel. | |||||||||||||||||||||
| CmpduACFeedName | 1.3.6.1.4.1.232.165.5.1.2.1.26 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory it would be A, B, Red, or White... StringLength=[50]. | |||||||||||||||||||||
| CmpduFloorName | 1.3.6.1.4.1.232.165.5.1.2.1.27 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Name of building floor entered by customer in GUI. StringLength=[50]. | |||||||||||||||||||||
| CmpduRoomName | 1.3.6.1.4.1.232.165.5.1.2.1.28 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Name of the room entered by customer in GUI. StringLength=[50]. | |||||||||||||||||||||
| CmpduRow | 1.3.6.1.4.1.232.165.5.1.2.1.29 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Data Center Row entered by customer in GUI. StringLength=[11]. | |||||||||||||||||||||
| CmpduRowPosition | 1.3.6.1.4.1.232.165.5.1.2.1.30 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Position in Row entered by customer in GUI. Null will be returned if not detected. StringLength=[11]. | |||||||||||||||||||||
| CmpduRackName | 1.3.6.1.4.1.232.165.5.1.2.1.31 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Name of the Rack entered by customer in GUI. Null will be returned if not detected. StringLength=[50]. | |||||||||||||||||||||
| CmpduRackHeight | 1.3.6.1.4.1.232.165.5.1.2.1.32 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Rack Type (22U, 42U, 50U...). Null will be returned if not detected. StringLength=[3]. | |||||||||||||||||||||
| CmpduRackID | 1.3.6.1.4.1.232.165.5.1.2.1.33 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory An unique ID to identify a rack, i.e. Rack SN. Null will be returned if not detected. StringLength=[50]. | |||||||||||||||||||||
| CmpduUPosition | 1.3.6.1.4.1.232.165.5.1.2.1.34 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory PDU Rack bottom U Start position, core U position. Null will be returned if not detected. | |||||||||||||||||||||
| CmpduPairedPDUUUID | 1.3.6.1.4.1.232.165.5.1.2.1.35 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory UUID of the PDU paired with this one. Null will be returned if not detected. StringLength=[50]. | |||||||||||||||||||||
| CmpduPairedPDUIP | 1.3.6.1.4.1.232.165.5.1.2.1.36 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory IP address of the PDU paired with this one. Null will be returned if not detected. StringLength=[16]. | |||||||||||||||||||||
| CmpduInstalledLocation | 1.3.6.1.4.1.232.165.5.1.2.1.37 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory 0=Left 0U side area or rack frame, 1= Right 0U side area or rack frame, 2= front RETMA rail, 3=back RETMA rail) - spatial location. A value of -1 will be returned if not detected. | |||||||||||||||||||||
| CmpduTotalPowerWatt | 1.3.6.1.4.1.232.165.5.1.2.1.38 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The total power for the whole iPDU in Watts. A value of -1 will be returned if the power is unable to be calculated. | |||||||||||||||||||||
| CmpduTotalPowerVA | 1.3.6.1.4.1.232.165.5.1.2.1.39 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The total power for the whole iPDU in VA. A value of -1 will be returned if the power is unable to be calculated. | |||||||||||||||||||||
| CmpduTotalPercentLoad | 1.3.6.1.4.1.232.165.5.1.2.1.40 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The whole iPDU's load in percent of rated capacity. Value is presented in 1/10 of the percentage i.e. 125 is 12.5%. A value of -1 will be returned if the current is unable to be measured. | |||||||||||||||||||||
| CmpduRegionalNominalVoltage | 1.3.6.1.4.1.232.165.5.1.2.1.41 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory value is either America(208V), Japan(202V) or blank for International Model | |||||||||||||||||||||
| NmpduOutput | 1.3.6.1.4.1.232.165.5.2 | ||||||||||||||||||||
| TmpduOutputTable | 1.3.6.1.4.1.232.165.5.2.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Indexed by mpduNumOutlet. So aggregate objects for each entry equal to (mpduNumMPDU multiplies mpduNumOutlet) before go to the next entry. i.e if 4 MPDU detected, display 6x4 indexes, 6x4 OutputStatus, 6x4 OutputBreakerRating...start with 1. | |||||||||||||||||||||
| RmpduOutputEntry | 1.3.6.1.4.1.232.165.5.2.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The output table entry containing the voltage, current, PF, percent load, VA, Watts for the Modular PDU. | |||||||||||||||||||||
| CmpduOutputIndex | 1.3.6.1.4.1.232.165.5.2.1.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for the MpduOutputEntry table. | |||||||||||||||||||||
| CmpduOutputStatus | 1.3.6.1.4.1.232.165.5.2.1.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The overall status of the device: off, on, problem. StringLength=[7]. | |||||||||||||||||||||
| CmpduOutputBreakerRating | 1.3.6.1.4.1.232.165.5.2.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The rating of each MPDU Output in Ampere. | |||||||||||||||||||||
| CmpduOutputSmartDevice | 1.3.6.1.4.1.232.165.5.2.1.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory A smart cord device detected: False, True. StringLength=[5]. | |||||||||||||||||||||
| CmpduOutputPercentLoad | 1.3.6.1.4.1.232.165.5.2.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The MPDU's each output load in percent of rated capacity. Value is presented in 1/10 of the percentage i.e. 125 is 12.5%. A value of -1 will be returned if the current is unable to be measured. | |||||||||||||||||||||
| CmpduOutputVoltage | 1.3.6.1.4.1.232.165.5.2.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The measured output voltage from the PDU meters in volts. Value is presented in 1/10 of the Volt i.e. 2095 is 209.5 V. A value of -1 will be returned if the voltage is unable to be measured. | |||||||||||||||||||||
| CmpduOutputCurrent | 1.3.6.1.4.1.232.165.5.2.1.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The measured output current from the PDU meters in amps. Value is presented in 1/100 of the Ampere i.e. 175 is 1.75 A. A value of -1 will be returned if the current is unable to be measured. | |||||||||||||||||||||
| CmpduOutputPowerVA | 1.3.6.1.4.1.232.165.5.2.1.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The total VA load (VI) measured on the PDU in VA. A value of -1 will be returned if the power is unable to be calculated. | |||||||||||||||||||||
| CmpduOutputPowerWatt | 1.3.6.1.4.1.232.165.5.2.1.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The total power load measured on the PDU in Watts. A value of -1 will be returned if the power is unable to be calculated. | |||||||||||||||||||||
| CmpduOutputPowerFactor | 1.3.6.1.4.1.232.165.5.2.1.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The power factor is presented in 1/100 of the unit i.e. 98 is 0.98. A value of -1 will be returned if the power factor is unable to be measured. | |||||||||||||||||||||
| CmpduOutputWarningThreshold | 1.3.6.1.4.1.232.165.5.2.1.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Report the User-set threshhold limit for Warning in percentage | |||||||||||||||||||||
| CmpduOutputCriticalThreshold | 1.3.6.1.4.1.232.165.5.2.1.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Report the User-set threshhold limit for Critical in percentage | |||||||||||||||||||||
| CmpduOutputPowerWattHour | 1.3.6.1.4.1.232.165.5.2.1.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Support Billing Grade Energy Metering in Watt-Hour. A value of -1 will be returned if the power is unable to be calculated. | |||||||||||||||||||||
| NmpduDeviceIdent | 1.3.6.1.4.1.232.165.5.3 | ||||||||||||||||||||
| TmpduDeviceIdentTable | 1.3.6.1.4.1.232.165.5.3.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Indexed by mpduNumOutlet. So aggregate objects for each entry equal to (mpduNumMPDU multiplies mpduNumOutlet) before go to the next entry. i.e if 4 MPDU detected, display 6x4 indexes, 6x4 mpduDeviceStatus, 6x4 DeviceUIDStatus...start with 1. | |||||||||||||||||||||
| RmpduDeviceIdentEntry | 1.3.6.1.4.1.232.165.5.3.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The ident table entry containing the name, model, manufacturer, firmware version, part number... for each smart device, null value for unknown device. | |||||||||||||||||||||
| CmpduDeviceIdentIndex | 1.3.6.1.4.1.232.165.5.3.1.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index is based on the total number of Smart Extension Bars plus smart devices (with smart power cord i.e. blades) detected. | |||||||||||||||||||||
| CmpduDeviceStatus | 1.3.6.1.4.1.232.165.5.3.1.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The overall status of the device: off, on, problem. StringLength=[8]. | |||||||||||||||||||||
| CmpduDeviceUIDStatus | 1.3.6.1.4.1.232.165.5.3.1.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The overall status of the device UID: off, on, blink. StringLength=[8]. | |||||||||||||||||||||
| CmpduDeviceNumOutlet | 1.3.6.1.4.1.232.165.5.3.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The number of outlets of detected the device. This variable indicates the number of rows in the breakers table. Default is 5 | |||||||||||||||||||||
| CmpduDeviceUHeight | 1.3.6.1.4.1.232.165.5.3.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Unit height of ext bar or device. Some device supports non-integer. Present value x100, when read back, divided by 100 to get 2 decimal points. | |||||||||||||||||||||
| CmpduDevicePowerRating | 1.3.6.1.4.1.232.165.5.3.1.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The device's Power Rating in VA. Null will be returned if not detected. StringLength=[8]. | |||||||||||||||||||||
| CmpduDeviceManufacturer | 1.3.6.1.4.1.232.165.5.3.1.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Device Manufacturer Name (e.g. Hewlett-Packard). Null will be returned if not detected. StringLength=[16]. | |||||||||||||||||||||
| CmpduDeviceType | 1.3.6.1.4.1.232.165.5.3.1.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Device's Type: Ext Bar, server, or network device... StringLength=[16]. | |||||||||||||||||||||
| CmpduDeviceModel | 1.3.6.1.4.1.232.165.5.3.1.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Device Model is Managed or Non-managed Ext Bar. Null will be returned if not detected. StringLength=[24]. | |||||||||||||||||||||
| CmpduDeviceName | 1.3.6.1.4.1.232.165.5.3.1.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The string identify the Device. i.e. 'BAR#1' (descriptive name) Null will be returned if not detected. StringLength=[32]. | |||||||||||||||||||||
| CmpduDeviceFirmwareVersion | 1.3.6.1.4.1.232.165.5.3.1.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The firmware revision level of Sm Ext Bar. Null will be returned if not detected. StringLength=[8]. | |||||||||||||||||||||
| CmpduDeviceHardwareVersion | 1.3.6.1.4.1.232.165.5.3.1.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The hardware version of Sm Ext Bar. Null will be returned if not detected. StringLength=[8]. | |||||||||||||||||||||
| CmpduDevicePartNumber | 1.3.6.1.4.1.232.165.5.3.1.1.13 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The device's part number. Null will be returned if not detected. StringLength=[21]. | |||||||||||||||||||||
| CmpduDeviceSerialNumber | 1.3.6.1.4.1.232.165.5.3.1.1.14 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The device's serial number. Null will be returned if not detected. StringLength=[21]. | |||||||||||||||||||||
| CmpduDeviceUUID | 1.3.6.1.4.1.232.165.5.3.1.1.15 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The device's UUID. Null will be returned if not detected. StringLength=[37]. | |||||||||||||||||||||
| CmpduDeviceIP | 1.3.6.1.4.1.232.165.5.3.1.1.16 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The device's IP Address. Null will be returned if not detected. StringLength=[16]. | |||||||||||||||||||||
| CmpduDeviceMAC | 1.3.6.1.4.1.232.165.5.3.1.1.17 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The device mgmt processor MAC Address. Null will be returned if not detected. StringLength=[18]. | |||||||||||||||||||||
| CmpduDevicePSUSlotNo | 1.3.6.1.4.1.232.165.5.3.1.1.18 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Device power supply logical slot number. | |||||||||||||||||||||
| CmpduDeviceUPosition | 1.3.6.1.4.1.232.165.5.3.1.1.19 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Device U start position. | |||||||||||||||||||||
| CmpduDeviceDetectionThreshold | 1.3.6.1.4.1.232.165.5.3.1.1.20 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Read device detection threshold between 10 and 50mA. | |||||||||||||||||||||
| NmpduSmExtBarOutlet | 1.3.6.1.4.1.232.165.5.4 | ||||||||||||||||||||
| TmpduSmExtBarOutletTable | 1.3.6.1.4.1.232.165.5.4.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Indexed by mpduDeviceNumOutlet. So aggregate objects for each entry equal to (mpduNumMPDU multiplies mpduNumOutlet multiplies mpduDeviceNumOutlet) before go to the next entry. i.e if 4 MPDU detected, display 5x6x4 indexes, 5x6x4 mpduSmExtBarOutletStatus, 5x6x4 mpduSmExtBarOutletUIDStatus...start with 1. | |||||||||||||||||||||
| RmpduSmExtBarOutletEntry | 1.3.6.1.4.1.232.165.5.4.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Entries contain status, measurements for each outlet (no PowerVA) Display null if it can't be measured or no device detected. | |||||||||||||||||||||
| CmpduSmExtBarOutletIndex | 1.3.6.1.4.1.232.165.5.4.1.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory The Index of Smart Extension Bar. | |||||||||||||||||||||
| CmpduSmExtBarOutletStatus | 1.3.6.1.4.1.232.165.5.4.1.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The overall status of the Smart Extension Bar's outlet: off, on, problem... StringLength=[3]. | |||||||||||||||||||||
| CmpduSmExtBarOutletUIDStatus | 1.3.6.1.4.1.232.165.5.4.1.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The overall status of the Smart Extension Bar's UID: off, on, blink... StringLength=[8]. | |||||||||||||||||||||
| CmpduSmExtBarOutletRating | 1.3.6.1.4.1.232.165.5.4.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Sm Ext Bar Outlet's Rating in Amp. A value of -1 will be returned if the stick is unable to detect. StringLength=[8]. | |||||||||||||||||||||
| CmpduSmExtBarOutletVoltage | 1.3.6.1.4.1.232.165.5.4.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The SM Ext Bar voltage in volts. Value is presented 1/10 of the Volt i.e. 2098 means 209.8 V. A value of -1 will be returned if the voltage is unable to be measured. | |||||||||||||||||||||
| CmpduSmExtBarOutletCurrent | 1.3.6.1.4.1.232.165.5.4.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The SM Ext Bar current draw in Amps. Value is presented in 1/100 of the Ampere i.e. 127 means 1.27 A. A value of -1 will be returned if the current is unable to be measured. | |||||||||||||||||||||
| CmpduSmExtBarOutletPowerWatt | 1.3.6.1.4.1.232.165.5.4.1.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Sm Ext Bar's Power measured in Watts. A value of -1 will be returned if the power is unable to be measured. | |||||||||||||||||||||
| CmpduSmExtBarOutletPowerFactor | 1.3.6.1.4.1.232.165.5.4.1.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The outlet's power factor in 0.01 unit. It is presented in 1/100 of the unit. i.e. 98 means 0.98. A value of -1 will be returned if the voltage is unable to be measured. | |||||||||||||||||||||
| CmpduSmExtBarOutletDeviceName | 1.3.6.1.4.1.232.165.5.4.1.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Device (Blade/Server/Storage) Name that connects to this Sm Ext Bar Outlet. Null will be returned if not detected. StringLength=[50]. | |||||||||||||||||||||
| CmpduSmExtBarOutletDeviceUUID | 1.3.6.1.4.1.232.165.5.4.1.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Device (Blade/Server/Storage) UUID that connects to this Sm Ext Bar Outlet. Null will be returned if not detected. StringLength=[37]. | |||||||||||||||||||||
| CmpduSmExtBarOutletDeviceProduct | 1.3.6.1.4.1.232.165.5.4.1.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Device (Blade/Server/Storage) Model that connects to this Sm Ext Bar Outlet. Null will be returned if not detected. StringLength=[40]. | |||||||||||||||||||||
| CmpduSmExtBarOutletDeviceIP | 1.3.6.1.4.1.232.165.5.4.1.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Device (Blade/Server/Storage) IP of iLO that connects to this Sm Ext Bar Outlet. Null will be returned if not detected. StringLength=[16]. | |||||||||||||||||||||
| CmpduSmExtBarOutletAutoDiscovered | 1.3.6.1.4.1.232.165.5.4.1.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Boolean values of 0 or 1. 1 means this Sm Ext Bar Outlet is able to get information from a blade with smart power supply (auto discovery is enabled)... | |||||||||||||||||||||
| CmpduSmExtBarOutletDeviceMAC | 1.3.6.1.4.1.232.165.5.4.1.1.14 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Device (Blade/Server/Storage) MAC address that connects to this Sm Ext Bar Outlet. Null will be returned if not detected. StringLength=[18]. | |||||||||||||||||||||
| CmpduSmExtBarOutletDeviceSN | 1.3.6.1.4.1.232.165.5.4.1.1.15 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Device (Blade/Server/Storage) Serial Number that connects to this Sm Ext Bar Outlet. Null will be returned if not detected. StringLength=[21]. | |||||||||||||||||||||
| CmpduSmExtBarOutletDevicePSSlotNo | 1.3.6.1.4.1.232.165.5.4.1.1.16 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Device (Blade/Server/Storage) Power Supply' Slot Number that connects to this Sm Ext Bar Outlet. A value of -1 will be returned if not detected. | |||||||||||||||||||||
| CmpduSmExtBarOutletDeviceUPosition | 1.3.6.1.4.1.232.165.5.4.1.1.17 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Device U start position. A value of -1 will be returned if not detected. | |||||||||||||||||||||
| CmpduSmExtBarOutletDeviceUHeight | 1.3.6.1.4.1.232.165.5.4.1.1.18 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Device U height. Enter -1 if not detected. Some device supports non-integer. Present value x100, when read back, divided by 100 to get 2 decimal points. | |||||||||||||||||||||
| CmpduSmExtBarOutletDeviceInstalledLocation | 1.3.6.1.4.1.232.165.5.4.1.1.19 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory 0=Left 0U side area or rack frame, 1= Right 0U side area or rack frame, 2= front RETMA rail, 3=back RETMA rail) - spatial location. A value of -1 will be returned if not detected. | |||||||||||||||||||||
| CmpduSmExtBarOutletPowerWattHour | 1.3.6.1.4.1.232.165.5.4.1.1.20 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Sm Ext Bar's Power measured in Watt-Hour support Billing Grade Energy Metering. A value of -1 will be returned if the power is unable to be measured. | |||||||||||||||||||||
| Noups | 1.3.6.1.4.1.232.165.6 | ||||||||||||||||||||
| NoupsIdent | 1.3.6.1.4.1.232.165.6.1 | ||||||||||||||||||||
| SoupsIdentManufacturer | 1.3.6.1.4.1.232.165.6.1.1 | DisplayString (SIZE (0..31)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · mandatory The UPS Manufacturer Name (e.g. Hewlett-Packard). | |||||||||||||||||||||
| SoupsIdentModel | 1.3.6.1.4.1.232.165.6.1.2 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory The UPS Model such as R-1500 G3. | |||||||||||||||||||||
| SoupsIdentSystemFWVersion | 1.3.6.1.4.1.232.165.6.1.3 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Display System firmware version. | |||||||||||||||||||||
| SoupsIdentPowerModuleFWVersion | 1.3.6.1.4.1.232.165.6.1.4 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Display Power Module firmware version. | |||||||||||||||||||||
| SoupsIdentOemCode | 1.3.6.1.4.1.232.165.6.1.5 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory A binary code indicating vendor. This should be a ?0x0c? for HP | |||||||||||||||||||||
| SoupsIdentSerialNumber | 1.3.6.1.4.1.232.165.6.1.6 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Get the UPS Serial Number (i.e. B00123456W). | |||||||||||||||||||||
| SoupsIdentPartNumber | 1.3.6.1.4.1.232.165.6.1.7 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Get the UPS Part Number (i.e. 204451-B21). | |||||||||||||||||||||
| NoupsBattery | 1.3.6.1.4.1.232.165.6.2 | ||||||||||||||||||||
| SoupsBatTimeRemaining | 1.3.6.1.4.1.232.165.6.2.1 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory Battery run time in seconds before UPS turns off due to low battery. | |||||||||||||||||||||
| SoupsBatVoltage | 1.3.6.1.4.1.232.165.6.2.2 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory Read the Total Battery voltage. | |||||||||||||||||||||
| SoupsBatCapacity | 1.3.6.1.4.1.232.165.6.2.3 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..100) · read-only · mandatory Battery percent charge. | |||||||||||||||||||||
| SoupsBatAbmStatus | 1.3.6.1.4.1.232.165.6.2.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Gives the status of the Advanced Battery Management; example:
batteryResting(3) is the state when the battery is fully charged and none of
the other actions (charging/discharging/floating) is being done.
| |||||||||||||||||||||
| SoupsBatTestStatus | 1.3.6.1.4.1.232.165.6.2.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Battery Test Status. UPS will support schedule testing only 7, 14, 30, or 60 days. Default is 14 days.
| |||||||||||||||||||||
| SoupsBatLatestTestDate | 1.3.6.1.4.1.232.165.6.2.6 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Get time and date of the latest battery test. | |||||||||||||||||||||
| SoupsBatReplacementDateBP1 | 1.3.6.1.4.1.232.165.6.2.7 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Get the battery replacement date of BP1. | |||||||||||||||||||||
| SoupsBatReplacementDateBP2 | 1.3.6.1.4.1.232.165.6.2.8 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Get the battery replacement date of BP2. | |||||||||||||||||||||
| SoupsBatToACDelay | 1.3.6.1.4.1.232.165.6.2.9 | INTEGER (0..150) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..150) · read-only · mandatory Get delay time switching from Battery mode to AC mode in ms. Default is 0ms, unit is increased per 100ms | |||||||||||||||||||||
| SoupsBatChargeDelay | 1.3.6.1.4.1.232.165.6.2.10 | INTEGER (0..9999) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..9999) · read-only · mandatory Get battery charge delay in second. Default is 0 (random) unit is increased per 10sec. | |||||||||||||||||||||
| SoupsBatNumModules | 1.3.6.1.4.1.232.165.6.2.11 | INTEGER (0..2) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2) · read-only · mandatory Number of battery modules detected by power unit. | |||||||||||||||||||||
| SoupsBatModel | 1.3.6.1.4.1.232.165.6.2.12 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Report 1U, 2U, or 3U Battery Pack, both BPs must be the same model. | |||||||||||||||||||||
| SoupsBatChargingPowerLevelUtility | 1.3.6.1.4.1.232.165.6.2.13 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory 3 charging power levels: 1100W, 555W, 190W. | |||||||||||||||||||||
| SoupsBatChargingPowerLevelGenerator | 1.3.6.1.4.1.232.165.6.2.14 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory 4 charging power levels: 1100W, 555W, 190W, No Charge. | |||||||||||||||||||||
| SoupsBatSharedConfig | 1.3.6.1.4.1.232.165.6.2.15 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory expect 3 values for shared BP configuration: PU single, PU master, PU slave. | |||||||||||||||||||||
| SoupsBatPackFWVerBP1 | 1.3.6.1.4.1.232.165.6.2.16 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Display Battery Pack 1 FW version. | |||||||||||||||||||||
| SoupsBatPackFWVerBP2 | 1.3.6.1.4.1.232.165.6.2.17 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Display Battery Pack 2 FW version. | |||||||||||||||||||||
| NoupsInput | 1.3.6.1.4.1.232.165.6.3 | ||||||||||||||||||||
| SoupsInputFrequency | 1.3.6.1.4.1.232.165.6.3.1 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The utility line frequency in tenths of Hz. | |||||||||||||||||||||
| SoupsInputLineBads | 1.3.6.1.4.1.232.165.6.3.2 | INTEGER (0..6) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..6) · read-only · mandatory The number of times the Input was out of tolerance in voltage or frequency. | |||||||||||||||||||||
| SoupsInputNumPhases | 1.3.6.1.4.1.232.165.6.3.3 | INTEGER (0..6) | RO | mandatory | |||||||||||||||||
| ToupsInputTable | 1.3.6.1.4.1.232.165.6.3.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to NumPhases and including the UpsInput group. | |||||||||||||||||||||
| RoupsInputEntry | 1.3.6.1.4.1.232.165.6.3.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The input table entry containing the current, voltage, etc.
| |||||||||||||||||||||
| CoupsInputPhase | 1.3.6.1.4.1.232.165.6.3.4.1.1 | INTEGER (0..6) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..6) · read-only · mandatory The number of the phase. Serves as index for input table. | |||||||||||||||||||||
| CoupsInputVoltage | 1.3.6.1.4.1.232.165.6.3.4.1.2 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured input voltage from the UPS meters in volts. | |||||||||||||||||||||
| CoupsInputCurrent | 1.3.6.1.4.1.232.165.6.3.4.1.3 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured input current from the UPS meters in amps. | |||||||||||||||||||||
| CoupsInputWatts | 1.3.6.1.4.1.232.165.6.3.4.1.4 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured input power in watts. | |||||||||||||||||||||
| SoupsInputPowerFactor | 1.3.6.1.4.1.232.165.6.3.5 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The measured real Input power factor with 2 decimals. | |||||||||||||||||||||
| SoupsInputDBType | 1.3.6.1.4.1.232.165.6.3.6 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Read the input Distribution Box type: 1- 480V-Y (US-5W NEMA plugs), 2- 480V-V (US-5W IEC plugs), 3- 415V-Y (EURO-5W IEC plugs), 4- 415V-Y (US/INTL-5W IEC plugs), 5- 380V-Y (China-5W hardwired). | |||||||||||||||||||||
| SoupsInputUpperVoltage | 1.3.6.1.4.1.232.165.6.3.7 | INTEGER (0..999) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..999) · read-only · mandatory Read the upper voltage range, 5 to 10 percent above the nominal voltage. Factory default is 10 percent. | |||||||||||||||||||||
| SoupsInputLowerVoltage | 1.3.6.1.4.1.232.165.6.3.8 | INTEGER (0..999) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..999) · read-only · mandatory Read the lower voltage range, 5 to 15 percent below the nominal voltage. Factory default is -15 percent. | |||||||||||||||||||||
| SoupsGeneratorDetection | 1.3.6.1.4.1.232.165.6.3.9 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory ATS sets a value of 1 to signal UPS that a generator is started so the UPS will charge Battery Pack using a different setting while it's on generator (intent to save all power to back up for the load).
| |||||||||||||||||||||
| SoupsInputWithGenerator | 1.3.6.1.4.1.232.165.6.3.10 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory A value of 1 when user known for sure Input has no Generator backup; a value of 2 tells Input Source could be from either Utility or Generator.
| |||||||||||||||||||||
| NoupsOutput | 1.3.6.1.4.1.232.165.6.4 | ||||||||||||||||||||
| SoupsOutputLoad | 1.3.6.1.4.1.232.165.6.4.1 | INTEGER (0..200) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..200) · read-only · mandatory The total UPS output load in percentage of rated capacity. | |||||||||||||||||||||
| SoupsOutputFrequency | 1.3.6.1.4.1.232.165.6.4.2 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The measured UPS output frequency in tenths of Hz. | |||||||||||||||||||||
| SoupsOutputNumPhases | 1.3.6.1.4.1.232.165.6.4.3 | INTEGER (0..6) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..6) · read-only · mandatory The number of metered output phases, serves as the table index. | |||||||||||||||||||||
| ToupsOutputTable | 1.3.6.1.4.1.232.165.6.4.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The Aggregate Object with number of entries equal to NumPhases and including the UpsOutput group. | |||||||||||||||||||||
| RoupsOutputEntry | 1.3.6.1.4.1.232.165.6.4.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Output Table Entry containing voltage, current, etc.
| |||||||||||||||||||||
| CoupsOutputPhase | 1.3.6.1.4.1.232.165.6.4.4.1.1 | INTEGER (0..6) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..6) · read-only · mandatory The number {1..3} of the output phase. | |||||||||||||||||||||
| CoupsOutputVoltage | 1.3.6.1.4.1.232.165.6.4.4.1.2 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured output voltage from the UPS metering in volts. | |||||||||||||||||||||
| CoupsOutputCurrent | 1.3.6.1.4.1.232.165.6.4.4.1.3 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured UPS output current in amps. | |||||||||||||||||||||
| CoupsOutputWatts | 1.3.6.1.4.1.232.165.6.4.4.1.4 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured real output power in watts. | |||||||||||||||||||||
| CoupsOutputLoadPerPhase | 1.3.6.1.4.1.232.165.6.4.4.1.5 | INTEGER (0..200) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..200) · read-only · mandatory The UPS output load per phase in percentage of rated capacity. | |||||||||||||||||||||
| SoupsOutputPowerFactor | 1.3.6.1.4.1.232.165.6.4.5 | INTEGER (0..2147483647) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..2147483647) · read-only · mandatory The measured real output power factor with 2 decimals. | |||||||||||||||||||||
| SoupsOutputSource | 1.3.6.1.4.1.232.165.6.4.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Indicate the source that UPS operating from when providing output.
| |||||||||||||||||||||
| NoupsMonitor | 1.3.6.1.4.1.232.165.6.5 | ||||||||||||||||||||
| SoupsMonitorAmbientTemp | 1.3.6.1.4.1.232.165.6.5.1 | INTEGER (-100..200) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (-100..200) · read-only · mandatory The reading of the internal PU Ambient temperature. | |||||||||||||||||||||
| SoupsMonitorBypassSCRTemp | 1.3.6.1.4.1.232.165.6.5.2 | INTEGER (-100..200) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (-100..200) · read-only · mandatory The reading of the internal PU Bypass SCR temperature. | |||||||||||||||||||||
| SoupsMonitorDDTemp | 1.3.6.1.4.1.232.165.6.5.3 | INTEGER (-100..200) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (-100..200) · read-only · mandatory The reading of the internal PU DD temperature. | |||||||||||||||||||||
| SoupsMonitorInverterTemp | 1.3.6.1.4.1.232.165.6.5.4 | INTEGER (-100..200) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (-100..200) · read-only · mandatory The reading of the internal PU DD temperature. | |||||||||||||||||||||
| SoupsMonitorChargerTemp | 1.3.6.1.4.1.232.165.6.5.5 | INTEGER (-100..200) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (-100..200) · read-only · mandatory The reading of the internal PU Charger temperature. | |||||||||||||||||||||
| SoupsMonitorBP1Temp | 1.3.6.1.4.1.232.165.6.5.6 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Display Battery Pack 1 Temeprature in F. If BP1 not connected the PU will return 255 and displayed as -not connect- | |||||||||||||||||||||
| SoupsMonitorBP2Temp | 1.3.6.1.4.1.232.165.6.5.7 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Display Battery Pack 2 Temperature in F. If BP2 not connected the PU will return 255 and displayed as -not connect- | |||||||||||||||||||||
| SoupsMonitorRestartDelay | 1.3.6.1.4.1.232.165.6.5.8 | INTEGER (1..150) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..150) · read-only · mandatory The reading of the AC Turn On Delay (Restart Delay). The value can be changed via front LCD Menu or inserted Module GUI. Default is 0ms, unit is increased per 100ms. | |||||||||||||||||||||
| SoupsMonitorACCLoadLevel | 1.3.6.1.4.1.232.165.6.5.9 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Read the set load level that ACC would be active from 0 to this percentage. Default is 20 percent. Select 0 to set it as Always On | |||||||||||||||||||||
| SoupsMonitorOperatingMode | 1.3.6.1.4.1.232.165.6.5.10 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Check if UPS is normal op, or on bypass, on inverter or ACC Active, | |||||||||||||||||||||
| SoupsMonitorOperationType | 1.3.6.1.4.1.232.165.6.5.11 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Check if UPS is operating as an UPS or ACC (PU only, no BP). | |||||||||||||||||||||
| SoupsTestTrap | 1.3.6.1.4.1.232.165.6.5.12 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Setting startTestTrap to 1 will initiate a TrapTest is sent out from Management Module. All other set values are invalid.
| |||||||||||||||||||||
| SoupsOnGenDuration | 1.3.6.1.4.1.232.165.6.5.13 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory When read, show the current On-Generator Duration set by user on UPS LCD or GUI .
| |||||||||||||||||||||
| SoupsRuntimeLimitation | 1.3.6.1.4.1.232.165.6.5.14 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory show the current setting for Runtime Limitation. When enable, it can last for 70sec or 3min.
| |||||||||||||||||||||
| NoupsRackDiscovery | 1.3.6.1.4.1.232.165.6.6 | ||||||||||||||||||||
| SoupsRackTagVersion | 1.3.6.1.4.1.232.165.6.6.1 | INTEGER (0..10) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..10) · read-only · mandatory Get the 1-wire contact FW version from EEPROM's Tag Version. Initial tag is 01 | |||||||||||||||||||||
| SoupsRackID | 1.3.6.1.4.1.232.165.6.6.2 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Get 10-digit Serial Number from the Location Discovery Strip mount in the front of the rack | |||||||||||||||||||||
| SoupsRackPartNumber | 1.3.6.1.4.1.232.165.6.6.3 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Get 10 or 12-digit Part Number xxxxxx-001 from the Location Discovery Strip mount in the front of the rack | |||||||||||||||||||||
| SoupsRackProductDescription | 1.3.6.1.4.1.232.165.6.6.4 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Get spatial data of rack: description of the Rack Name. | |||||||||||||||||||||
| SoupsRackEncULocation | 1.3.6.1.4.1.232.165.6.6.5 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · mandatory Tell where the Location Discovery Strip is mounted in the rack. B for Back, F for Front, L for Left and R for Right. | |||||||||||||||||||||
| SoupsRackUHeight | 1.3.6.1.4.1.232.165.6.6.6 | INTEGER (0..50) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..50) · read-only · mandatory Get spatial data of rack: U-height of the rack can be 36U, 42U, or 47U model. | |||||||||||||||||||||
| SoupsRackPUUPosition | 1.3.6.1.4.1.232.165.6.6.7 | INTEGER (0..50) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..50) · read-only · mandatory Get the U-position of the PU where it is installed in the rack. The U position range is from 1-50. | |||||||||||||||||||||
| SoupsRackPUUHeight | 1.3.6.1.4.1.232.165.6.6.8 | INTEGER (0..10) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..10) · read-only · mandatory Get the U-Height of the Power Unit. PU height is either 1U or 2U. | |||||||||||||||||||||
| SoupsRackBP1UPosition | 1.3.6.1.4.1.232.165.6.6.9 | INTEGER (0..50) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..50) · read-only · mandatory Get the U-Position of the Battery Pack 1, installed right below the PU. Range is from 1 to 50. | |||||||||||||||||||||
| SoupsRackBP1UHeight | 1.3.6.1.4.1.232.165.6.6.10 | INTEGER (0..10) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..10) · read-only · mandatory Get the U-Height of the BP 1. BP is either 1U, 2U, and 3U | |||||||||||||||||||||
| SoupsRackBP2UPosition | 1.3.6.1.4.1.232.165.6.6.11 | INTEGER (0..50) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..50) · read-only · mandatory Get the U-Position of the Battery Pack 2, installed right below the BP1. Range is from 1 to 50. | |||||||||||||||||||||
| SoupsRackBP2UHeight | 1.3.6.1.4.1.232.165.6.6.12 | INTEGER (0..10) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..10) · read-only · mandatory Get the U-Height of the BP 2. BP is either 1U, 2U, and 3U | |||||||||||||||||||||
| Npdu2 | 1.3.6.1.4.1.232.165.7 | ||||||||||||||||||||
| Npdu2Ident | 1.3.6.1.4.1.232.165.7.1 | ||||||||||||||||||||
| Spdu2NumberPDU | 1.3.6.1.4.1.232.165.7.1.1 | INTEGER (1..2) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..2) · read-only · mandatory The number of PDUs detected (in its daisy chain). | |||||||||||||||||||||
| Tpdu2IdentTable | 1.3.6.1.4.1.232.165.7.1.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to pdu2NumberPDU . | |||||||||||||||||||||
| Rpdu2IdentEntry | 1.3.6.1.4.1.232.165.7.1.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The ident table entry containing the name, model, manufacturer, firmware version, part number, etc.
| |||||||||||||||||||||
| Cpdu2IdentIndex | 1.3.6.1.4.1.232.165.7.1.2.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for the Pdu2IdentEntry table. | |||||||||||||||||||||
| Cpdu2Name | 1.3.6.1.4.1.232.165.7.1.2.1.2 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The string identify the device in daisy chain. Example PDU A. | |||||||||||||||||||||
| Cpdu2Model | 1.3.6.1.4.1.232.165.7.1.2.1.3 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The Device Model. | |||||||||||||||||||||
| Cpdu2Manufacturer | 1.3.6.1.4.1.232.165.7.1.2.1.4 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The Device Manufacturer Name (e.g. Hewlett-Packard). | |||||||||||||||||||||
| Cpdu2FirmwareVersion | 1.3.6.1.4.1.232.165.7.1.2.1.5 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The firmware revision level of the device. | |||||||||||||||||||||
| Cpdu2PartNumber | 1.3.6.1.4.1.232.165.7.1.2.1.6 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The device part number. Example AF400A. | |||||||||||||||||||||
| Cpdu2SerialNumber | 1.3.6.1.4.1.232.165.7.1.2.1.7 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The device serial number, 10- or 16-digit. | |||||||||||||||||||||
| Cpdu2Status | 1.3.6.1.4.1.232.165.7.1.2.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The overall status of the device. A value of OK(2) indicates the device is operating normally. A value of degraded(3) indicates the device is operating with warning indicators. A value of failed(4) indicates the device is operating with critical indicators.
| |||||||||||||||||||||
| Cpdu2Controllable | 1.3.6.1.4.1.232.165.7.1.2.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This object indicates whether or not the device is controllable.
| |||||||||||||||||||||
| Cpdu2InputPhaseCount | 1.3.6.1.4.1.232.165.7.1.2.1.10 | INTEGER (0..63) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..63) · read-only · mandatory The number of input phase on this pdu 1,2,3. | |||||||||||||||||||||
| Cpdu2GroupCount | 1.3.6.1.4.1.232.165.7.1.2.1.11 | INTEGER (0..63) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..63) · read-only · mandatory The number of groups (breakers) on this pdu. | |||||||||||||||||||||
| Cpdu2OutletCount | 1.3.6.1.4.1.232.165.7.1.2.1.12 | INTEGER (0..63) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..63) · read-only · mandatory The number of outlets in this PDU. | |||||||||||||||||||||
| Npdu2Input | 1.3.6.1.4.1.232.165.7.2 | ||||||||||||||||||||
| Tpdu2InputTable | 1.3.6.1.4.1.232.165.7.2.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to pdu2NumberPDU . | |||||||||||||||||||||
| Rpdu2InputEntry | 1.3.6.1.4.1.232.165.7.2.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The ident table entry containing the VA, Watts, WH, etc.
| |||||||||||||||||||||
| Cpdu2InputType | 1.3.6.1.4.1.232.165.7.2.1.1.1 | INTEGER | RO | mandatory | singlePhase(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory Type of input - single phase, split phase, three phase delta, or three phase wye.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2InputFrequency | 1.3.6.1.4.1.232.165.7.2.1.1.2 | INTEGER (0..2147483647) | RO | mandatory | 500 | ||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured input frequency from the PDU meters in tenths of Hz. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2InputFrequencyStatus | 1.3.6.1.4.1.232.165.7.2.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured input frequency relative to the nominal frequency and the admitted tolerance.
| |||||||||||||||||||||
| Cpdu2InputPowerVA | 1.3.6.1.4.1.232.165.7.2.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A total input VA of all phases. Units are VA. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2InputPowerWatts | 1.3.6.1.4.1.232.165.7.2.1.1.5 | INTEGER | RO | mandatory | 97 | ||||||||||||||||
column · INTEGER · read-only · mandatory A total input Watts of all phases. Units are Watts. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2InputPowerWattHour | 1.3.6.1.4.1.232.165.7.2.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A total input Watt-Hour value for all phases. Units are WH. This value can be reset to 0 using GUI. In that case, the pdu2InputPowerWattHourTimer will be reset as well A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2InputPowerWattHourTimer | 1.3.6.1.4.1.232.165.7.2.1.1.7 | DisplayString (SIZE (0..22)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..22)) · read-only · mandatory A Timestamp of when the Total Input WH was last reset. | |||||||||||||||||||||
| Cpdu2InputPowerFactor | 1.3.6.1.4.1.232.165.7.2.1.1.8 | INTEGER | RO | mandatory | 751 | ||||||||||||||||
column · INTEGER · read-only · mandatory An input PF value. Units are in thousandths, for example a power factor
of 0.958 would be returned as 958, and 0.92 would be returned as 920.
A negative value indicates that this object is not available.Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2InputPowerVAR | 1.3.6.1.4.1.232.165.7.2.1.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory An input VAR value. Units are VAR. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Tpdu2InputPhaseTable | 1.3.6.1.4.1.232.165.7.2.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to number of PDUs (pdu2NumberPDU) and number of input phase (pdu2InputPhaseCount). | |||||||||||||||||||||
| Rpdu2InputPhaseEntry | 1.3.6.1.4.1.232.165.7.2.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The input table entry containing the voltage, current, frequency, power for each phase. Entries are given with number of pdu and number of input phase 1, 2, or 3. | |||||||||||||||||||||
| Cpdu2InputPhaseIndex | 1.3.6.1.4.1.232.165.7.2.2.1.1 | INTEGER (0..100) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for the Pdu2InputEntry table. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2InputPhaseVoltageMeasType | 1.3.6.1.4.1.232.165.7.2.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Value indicates what input voltage is being measured in this table row - single phase voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2, phase 2 to phase 3, or phase 3 to phase 1.
| |||||||||||||||||||||
| Cpdu2InputPhaseVoltage | 1.3.6.1.4.1.232.165.7.2.2.1.3 | INTEGER | RO | mandatory | 242440 | ||||||||||||||||
column · INTEGER · read-only · mandatory An input voltage measurement value. Units are millivolts. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2InputPhaseVoltageThStatus | 1.3.6.1.4.1.232.165.7.2.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured input voltage relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdu2InputPhaseVoltageThLowerWarning | 1.3.6.1.4.1.232.165.7.2.2.1.5 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Lower warning threshold. Units are millivolts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2InputPhaseVoltageThLowerCritical | 1.3.6.1.4.1.232.165.7.2.2.1.6 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Lower critical threshold. Units are millivolts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2InputPhaseVoltageThUpperWarning | 1.3.6.1.4.1.232.165.7.2.2.1.7 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Upper warning threshold. Units are millivolts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2InputPhaseVoltageThUpperCritical | 1.3.6.1.4.1.232.165.7.2.2.1.8 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Upper critical threshold. Units are millivolts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2InputPhaseCurrentMeasType | 1.3.6.1.4.1.232.165.7.2.2.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Which input wire is being measured in this table row - single phase, neutral, phase 1, phase 2, or phase 3.
| |||||||||||||||||||||
| Cpdu2InputPhaseCurrentRating | 1.3.6.1.4.1.232.165.7.2.2.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Rated current capacity of the input. A negative value indicates that the hardware current capacity is unknown. Units are milliamps. | |||||||||||||||||||||
| Cpdu2InputPhaseCurrent | 1.3.6.1.4.1.232.165.7.2.2.1.11 | INTEGER | RO | mandatory | 535 | ||||||||||||||||
column · INTEGER · read-only · mandatory An input current measurement value. Units are milliamps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2InputPhaseCurrentThStatus | 1.3.6.1.4.1.232.165.7.2.2.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured input current relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdu2InputPhaseCurrentThLowerWarning | 1.3.6.1.4.1.232.165.7.2.2.1.13 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Lower warning threshold. Units are milliamps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2InputPhaseCurrentThLowerCritical | 1.3.6.1.4.1.232.165.7.2.2.1.14 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Lower critical threshold. Units are milliamps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2InputPhaseCurrentThUpperWarning | 1.3.6.1.4.1.232.165.7.2.2.1.15 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Upper warning threshold. Units are milliamps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2InputPhaseCurrentThUpperCritical | 1.3.6.1.4.1.232.165.7.2.2.1.16 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Upper critical threshold. Units are milliamps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2InputPhaseCurrentCrestFactor | 1.3.6.1.4.1.232.165.7.2.2.1.17 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Current crest factor. Units are in milli, for example a crest factor of
1.414 will be returned as 1414. A negative value indicates
that this object is not available. | |||||||||||||||||||||
| Cpdu2InputPhaseCurrentPercentLoad | 1.3.6.1.4.1.232.165.7.2.2.1.18 | INTEGER | RO | mandatory | 3 | ||||||||||||||||
column · INTEGER · read-only · mandatory Current percent load, based on the rated current capacity. Units are percentage, for example 80% will be returned as 80. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2InputPhasePowerMeasType | 1.3.6.1.4.1.232.165.7.2.2.1.19 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Which input wire is being measured in this table row - single phase, neutral, phase 1, phase 2, or phase 3.
| |||||||||||||||||||||
| Cpdu2InputPhasePowerVA | 1.3.6.1.4.1.232.165.7.2.2.1.20 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory An input VA value. Units are VA. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2InputPhasePowerWatts | 1.3.6.1.4.1.232.165.7.2.2.1.21 | INTEGER | RO | mandatory | 97 | ||||||||||||||||
column · INTEGER · read-only · mandatory An input Watts value. Units are Watts. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2InputPhasePowerWattHour | 1.3.6.1.4.1.232.165.7.2.2.1.22 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A Watt-Hour value for each Input phase. Units are WH. This value can be reset to 0 using GUI. In that case, the pdu2InputPhasePowerWattHourTimer will be reset as well A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2InputPhasePowerWattHourTimer | 1.3.6.1.4.1.232.165.7.2.2.1.23 | DisplayString (SIZE (0..22)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..22)) · read-only · mandatory Timestamp of when input Watt-hours (inputWh) was last reset. | |||||||||||||||||||||
| Cpdu2InputPhasePowerFactor | 1.3.6.1.4.1.232.165.7.2.2.1.24 | INTEGER | RO | mandatory | 751 | ||||||||||||||||
column · INTEGER · read-only · mandatory An input PF value. Units are in thousandths, for example a power factor
of 0.958 would be returned as 958, and 0.92 would be returned
as 920. A negative value indicates that this object is not available.Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2InputPhasePowerVAR | 1.3.6.1.4.1.232.165.7.2.2.1.25 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory An input VAR value. Units are VAR. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Npdu2Group | 1.3.6.1.4.1.232.165.7.3 | ||||||||||||||||||||
| Tpdu2GroupTable | 1.3.6.1.4.1.232.165.7.3.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to number of PDUs and number of breakers (pdu2GroupCount). | |||||||||||||||||||||
| Rpdu2GroupEntry | 1.3.6.1.4.1.232.165.7.3.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The input table entry containing the name, voltages, currents, power, etc.
| |||||||||||||||||||||
| Cpdu2GroupIndex | 1.3.6.1.4.1.232.165.7.3.1.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for the Pdu2GroupEntry table. | |||||||||||||||||||||
| Cpdu2GroupName | 1.3.6.1.4.1.232.165.7.3.1.1.2 | DisplayString (SIZE (1..31)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (1..31)) · read-only · mandatory A descriptive name for the group. | |||||||||||||||||||||
| Cpdu2GroupType | 1.3.6.1.4.1.232.165.7.3.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The type of the group. (5) has no breaker
| |||||||||||||||||||||
| Cpdu2GroupVoltageMeasType | 1.3.6.1.4.1.232.165.7.3.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Value indicates what input voltage is being measured in this table row - single phase voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2, phase 2 to phase 3, or phase 3 to phase 1.
| |||||||||||||||||||||
| Cpdu2GroupVoltage | 1.3.6.1.4.1.232.165.7.3.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Units are millivolts. | |||||||||||||||||||||
| Cpdu2GroupVoltageThStatus | 1.3.6.1.4.1.232.165.7.3.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured group voltage relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdu2GroupVoltageThLowerWarning | 1.3.6.1.4.1.232.165.7.3.1.1.7 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Lower warning threshold. Units are millivolts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupVoltageThLowerCritical | 1.3.6.1.4.1.232.165.7.3.1.1.8 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Lower critical threshold. Units are millivolts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupVoltageThUpperWarning | 1.3.6.1.4.1.232.165.7.3.1.1.9 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Upper warning threshold. Units are millivolts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupVoltageThUpperCritical | 1.3.6.1.4.1.232.165.7.3.1.1.10 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Upper critical threshold. Units are millivolts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2groupCurrentRating | 1.3.6.1.4.1.232.165.7.3.1.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Rated current capacity of the group. Units are milliamps. A negative value indicates that the hardware current capacity is unknown (it will always be unknown for custom groups). | |||||||||||||||||||||
| Cpdu2GroupCurrent | 1.3.6.1.4.1.232.165.7.3.1.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A group current measurement value. Units are milliamps. | |||||||||||||||||||||
| Cpdu2GroupCurrentThStatus | 1.3.6.1.4.1.232.165.7.3.1.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured group current relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdu2GroupCurrentThLowerWarning | 1.3.6.1.4.1.232.165.7.3.1.1.14 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Lower warning threshold. Units are milliamps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupCurrentThLowerCritical | 1.3.6.1.4.1.232.165.7.3.1.1.15 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Lower critical threshold. Units are milliamps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupCurrentThUpperWarning | 1.3.6.1.4.1.232.165.7.3.1.1.16 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Upper warning threshold. Units are milliamps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupCurrentThUpperCritical | 1.3.6.1.4.1.232.165.7.3.1.1.17 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Upper critical threshold. Units are milliamps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupCurrentCrestFactor | 1.3.6.1.4.1.232.165.7.3.1.1.18 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Current crest factor. Units are in milli, for example a crest factor of
1.414 will be returned as 1414. A negative value indicates
that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupCurrentPercentLoad | 1.3.6.1.4.1.232.165.7.3.1.1.19 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Current percent load, based on the rated current capacity. Units are percentage, for example 80% will be returned as 80. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupPowerVA | 1.3.6.1.4.1.232.165.7.3.1.1.20 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A group VA value. Units are VA. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupPowerWatts | 1.3.6.1.4.1.232.165.7.3.1.1.21 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A group Watts value. Units are Watts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupPowerWattHour | 1.3.6.1.4.1.232.165.7.3.1.1.22 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A Watt-Hour value for each section. Units are WH. This value can be reset to 0 using GUI. In that case, the pdu2GroupPowerWattHourTimer will be reset as well. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupPowerWattHourTimer | 1.3.6.1.4.1.232.165.7.3.1.1.23 | DisplayString (SIZE (0..22)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..22)) · read-only · mandatory Timestamp of when group Watt-hours (groupWh) was last reset. | |||||||||||||||||||||
| Cpdu2GroupPowerFactor | 1.3.6.1.4.1.232.165.7.3.1.1.24 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A group PF value. Units are in thousandths, for example a power factor of 0.958 would be returned as 958, and 0.92 would be returned as 920. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupPowerVAR | 1.3.6.1.4.1.232.165.7.3.1.1.25 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A group VAR value. Units are VAR. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2GroupOutletCount | 1.3.6.1.4.1.232.165.7.3.1.1.26 | INTEGER (0..63) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..63) · read-only · mandatory The number of outlets in each group (breaker). | |||||||||||||||||||||
| Cpdu2GroupBreakerStatus | 1.3.6.1.4.1.232.165.7.3.1.1.27 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Only applicable to groups with breaker. Indicates whether a breaker is turned off or on.
| |||||||||||||||||||||
| Npdu2Environment | 1.3.6.1.4.1.232.165.7.4 | ||||||||||||||||||||
| Tpdu2EnvProbeTable | 1.3.6.1.4.1.232.165.7.4.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of environment probe (1 per PDU) for temperature, humidity, and contacts. The number of entries is given by number of PDUs in daisy chain. | |||||||||||||||||||||
| Rpdu2EnvProbeEntry | 1.3.6.1.4.1.232.165.7.4.1.1 | NA | mandatory | ||||||||||||||||||
| Cpdu2TemperatureScale | 1.3.6.1.4.1.232.165.7.4.1.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Scale used to return temperature objects.
| |||||||||||||||||||||
| Cpdu2TemperatureCount | 1.3.6.1.4.1.232.165.7.4.1.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Max number of temperature measurements (1 per probe). | |||||||||||||||||||||
| Cpdu2HumidityCount | 1.3.6.1.4.1.232.165.7.4.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Max number of humidity measurements (1 per probe). | |||||||||||||||||||||
| Cpdu2ContactCount | 1.3.6.1.4.1.232.165.7.4.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Max number of contact sensors (1 per probe). | |||||||||||||||||||||
| Tpdu2TemperatureTable | 1.3.6.1.4.1.232.165.7.4.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of temperature probe measurements. The number of entries are given by number of pdu and pdu2TemperatureCount. | |||||||||||||||||||||
| Rpdu2TemperatureEntry | 1.3.6.1.4.1.232.165.7.4.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry for a temperature measurement. | |||||||||||||||||||||
| Cpdu2TemperatureIndex | 1.3.6.1.4.1.232.165.7.4.2.1.1 | INTEGER (1..2) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (1..2) · read-only · mandatory A unique value for each temperature probe measurement. Its value ranges from 1 to temperatureCount. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2TemperatureName | 1.3.6.1.4.1.232.165.7.4.2.1.2 | DisplayString (SIZE (1..31)) | RO | mandatory | | ||||||||||||||||
column · DisplayString (SIZE (1..31)) · read-only · mandatory A descriptive name for the temperature probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2TemperatureProbeStatus | 1.3.6.1.4.1.232.165.7.4.2.1.3 | INTEGER | RO | mandatory | disconnected(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether a probe is connected or not.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2TemperatureValue | 1.3.6.1.4.1.232.165.7.4.2.1.4 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory Units are in tenths of a degree (either Fahrenheit or Celsius). Divide by ten to get degrees. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2TemperatureThStatus | 1.3.6.1.4.1.232.165.7.4.2.1.5 | INTEGER | RO | mandatory | good(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured temperature relative to the configured thresholds.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2TemperatureThLowerWarning | 1.3.6.1.4.1.232.165.7.4.2.1.6 | INTEGER (-1..150000) | RO | mandatory | 100 | ||||||||||||||||
column · INTEGER (-1..150000) · read-only · mandatory Lower warning threshold. Units are tenths of a degree. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2TemperatureThLowerCritical | 1.3.6.1.4.1.232.165.7.4.2.1.7 | INTEGER (-1..150000) | RO | mandatory | 50 | ||||||||||||||||
column · INTEGER (-1..150000) · read-only · mandatory Lower critical threshold. Units are tenths of a degree. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2TemperatureThUpperWarning | 1.3.6.1.4.1.232.165.7.4.2.1.8 | INTEGER (-1..150000) | RO | mandatory | 500 | ||||||||||||||||
column · INTEGER (-1..150000) · read-only · mandatory Upper warning threshold. Units are tenths of a degree. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2TemperatureThUpperCritical | 1.3.6.1.4.1.232.165.7.4.2.1.9 | INTEGER (-1..150000) | RO | mandatory | 650 | ||||||||||||||||
column · INTEGER (-1..150000) · read-only · mandatory Upper critical threshold. Units are tenths of a degree. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tpdu2HumidityTable | 1.3.6.1.4.1.232.165.7.4.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of humidity probe measurements. The number of entries are given by number of pdu and pdu2HumidityCount. | |||||||||||||||||||||
| Rpdu2HumidityEntry | 1.3.6.1.4.1.232.165.7.4.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry for a humidity measurement. | |||||||||||||||||||||
| Cpdu2HumidityIndex | 1.3.6.1.4.1.232.165.7.4.3.1.1 | INTEGER (1..2) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (1..2) · read-only · mandatory A unique value for each humidity probe measurement. Its value ranges from 1 to pdu2HumidityCount per pdu. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2HumidityName | 1.3.6.1.4.1.232.165.7.4.3.1.2 | DisplayString (SIZE (1..31)) | RO | mandatory | | ||||||||||||||||
column · DisplayString (SIZE (1..31)) · read-only · mandatory A descriptive name for the humidity probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2HumidityProbeStatus | 1.3.6.1.4.1.232.165.7.4.3.1.3 | INTEGER | RO | mandatory | disconnected(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether a probe is connected or not.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2HumidityValue | 1.3.6.1.4.1.232.165.7.4.3.1.4 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory Units are tenths of a percent relative humidity. Divide the value by 10 to get %RH. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2HumidityThStatus | 1.3.6.1.4.1.232.165.7.4.3.1.5 | INTEGER | RO | mandatory | good(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured humidity relative to the configured thresholds.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2HumidityThLowerWarning | 1.3.6.1.4.1.232.165.7.4.3.1.6 | INTEGER (-1..1000) | RO | mandatory | 200 | ||||||||||||||||
column · INTEGER (-1..1000) · read-only · mandatory Lower warning threshold. Units are 0.1 %RH. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2HumidityThLowerCritical | 1.3.6.1.4.1.232.165.7.4.3.1.7 | INTEGER (-1..1000) | RO | mandatory | 100 | ||||||||||||||||
column · INTEGER (-1..1000) · read-only · mandatory Lower critical threshold. Units are 0.1 %RH. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2HumidityThUpperWarning | 1.3.6.1.4.1.232.165.7.4.3.1.8 | INTEGER (-1..1000) | RO | mandatory | 650 | ||||||||||||||||
column · INTEGER (-1..1000) · read-only · mandatory Upper warning threshold. Units are 0.1 %RH. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2HumidityThUpperCritical | 1.3.6.1.4.1.232.165.7.4.3.1.9 | INTEGER (-1..1000) | RO | mandatory | 900 | ||||||||||||||||
column · INTEGER (-1..1000) · read-only · mandatory Upper critical threshold. Units are 0.1 %RH. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tpdu2ContactTable | 1.3.6.1.4.1.232.165.7.4.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of contact sensors. The number of entries are given by number of pdu and pdu2ContactCount. | |||||||||||||||||||||
| Rpdu2ContactEntry | 1.3.6.1.4.1.232.165.7.4.4.1 | NA | mandatory | ||||||||||||||||||
| Cpdu2ContactIndex | 1.3.6.1.4.1.232.165.7.4.4.1.1 | INTEGER (1..3) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..3) · read-only · mandatory A unique value for each contact sensor. Its value ranges from 1 to contactCount. | |||||||||||||||||||||
| Cpdu2ContactName | 1.3.6.1.4.1.232.165.7.4.4.1.2 | DisplayString (SIZE (1..31)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (1..31)) · read-only · mandatory A descriptive name for the contact sensor. | |||||||||||||||||||||
| Cpdu2ContactProbeStatus | 1.3.6.1.4.1.232.165.7.4.4.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether a probe is connected or not. Will not be returned if the contact sensor is internal to the ePDU, in that case only contactState should be read.
| |||||||||||||||||||||
| Cpdu2ContactState | 1.3.6.1.4.1.232.165.7.4.4.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The state of the contact sensor.
| |||||||||||||||||||||
| Npdu2Outlet | 1.3.6.1.4.1.232.165.7.5 | ||||||||||||||||||||
| Tpdu2OutletTable | 1.3.6.1.4.1.232.165.7.5.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to Number of PDU (pdu2IdentIndex) and Number of outlet per PDU (pdu2OutletIndex). | |||||||||||||||||||||
| Rpdu2OutletEntry | 1.3.6.1.4.1.232.165.7.5.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The Outlet table entry containing the type, voltage, current etc. | |||||||||||||||||||||
| Cpdu2OutletIndex | 1.3.6.1.4.1.232.165.7.5.1.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for each outlet, value from 1 to the number of outlets per PDU. | |||||||||||||||||||||
| Cpdu2OutletName | 1.3.6.1.4.1.232.165.7.5.1.1.2 | DisplayString (SIZE (1..31)) | RO | mandatory | Outlet L1-1 | ||||||||||||||||
column · DisplayString (SIZE (1..31)) · read-only · mandatory A descriptive name for the outlet. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2OutletType | 1.3.6.1.4.1.232.165.7.5.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Type of this outlet - C13, C19.
| |||||||||||||||||||||
| Cpdu2OutletCurrentRating | 1.3.6.1.4.1.232.165.7.5.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Rated current capacity of this outlet. Units are milliamps. A negative value indicates that the hardware current capacity is unknown. | |||||||||||||||||||||
| Cpdu2OutletCurrent | 1.3.6.1.4.1.232.165.7.5.1.1.5 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory A outlet current measurement value. Units are milliamps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2OutletCurrentThStatus | 1.3.6.1.4.1.232.165.7.5.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured outlet current relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdu2OutletCurrentThLowerWarning | 1.3.6.1.4.1.232.165.7.5.1.1.7 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Lower warning threshold. Units are milliamps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2OutletCurrentThLowerCritical | 1.3.6.1.4.1.232.165.7.5.1.1.8 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Lower critical threshold. Units are milliamps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2OutletCurrentThUpperWarning | 1.3.6.1.4.1.232.165.7.5.1.1.9 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Upper warning threshold. Units are milliamps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2OutletCurrentThUpperCritical | 1.3.6.1.4.1.232.165.7.5.1.1.10 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Upper critical threshold. Units are milliamps. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2OutletCurrentCrestFactor | 1.3.6.1.4.1.232.165.7.5.1.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Current crest factor. Units are in milli, for example a crest factor of
1.414 will be returned as 1414. A negative value indicates
that this object is not available. | |||||||||||||||||||||
| Cpdu2OutletCurrentPercentLoad | 1.3.6.1.4.1.232.165.7.5.1.1.12 | INTEGER | RO | mandatory | -1 | ||||||||||||||||
column · INTEGER · read-only · mandatory Current percent load, based on the rated current capacity. Units are percentage, for example 80% will be returned as 80. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2OutletVA | 1.3.6.1.4.1.232.165.7.5.1.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A outlet VA value. Units are VA. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2OutletWatts | 1.3.6.1.4.1.232.165.7.5.1.1.14 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory A outlet Watts value. Units are Watts. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2OutletWh | 1.3.6.1.4.1.232.165.7.5.1.1.15 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A Watt-Hour value for each outlet. Units are WH.
This object is writable so that it can be reset to 0. When it is
written to, the pdu2OutletWhTimer will be reset updated as well
A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu2OutletWhTimer | 1.3.6.1.4.1.232.165.7.5.1.1.16 | DisplayString (SIZE (0..22)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..22)) · read-only · mandatory Timestamp (date and time) of outlet Watt-hours was last reset. | |||||||||||||||||||||
| Cpdu2OutletPowerFactor | 1.3.6.1.4.1.232.165.7.5.1.1.17 | INTEGER | RO | mandatory | 1000 | ||||||||||||||||
column · INTEGER · read-only · mandatory An outlet PF value. Units are in thousandths, for example a power factor
of 0.958 would be returned as 958, and 0.92 would be returned
as 920. A negative value indicates that this object is not available.Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2OutletVAR | 1.3.6.1.4.1.232.165.7.5.1.1.18 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory An outlet VAR value. Units are VAR. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Tpdu2OutletControlTable | 1.3.6.1.4.1.232.165.7.5.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to Number of PDU (pdu2IdentIndex) and Number of outlets per PDU (pdu2OutletIndex). | |||||||||||||||||||||
| Rpdu2OutletControlEntry | 1.3.6.1.4.1.232.165.7.5.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The Outlet table entry containing the type, voltage, current etc. | |||||||||||||||||||||
| Cpdu2OutletControlStatus | 1.3.6.1.4.1.232.165.7.5.2.1.1 | INTEGER | RO | mandatory | off(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory current state of a control outlet.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu2OutletControlOffCmd | 1.3.6.1.4.1.232.165.7.5.2.1.2 | INTEGER (-1..99999) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..99999) · read-write · mandatory When write, once issued, the outlet will turn Off immediately.
0-n: Time in seconds until the outlet command is issued
-1: Cancel a pending outlet Off command
When read, returns -1 if no command is pending, or the current downcount in
seconds of a pending command. | |||||||||||||||||||||
| Cpdu2OutletControlOnCmd | 1.3.6.1.4.1.232.165.7.5.2.1.3 | INTEGER (-1..99999) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..99999) · read-write · mandatory When write, once issued, the outlet will turn On immediately.
0-n: Time in seconds until the outlet command is issued
-1: Cancel a pending outlet On command
When read, returns -1 if no command is pending, or the current downcount in
seconds of a pending command. | |||||||||||||||||||||
| Cpdu2OutletControlRebootCmd | 1.3.6.1.4.1.232.165.7.5.2.1.4 | INTEGER (-1..99999) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..99999) · read-write · mandatory When write, for outlets that are On prior to this Reboot command, they will
switch Off immediately when the command is issued, remain Off for
outletControlRebootOffTime seconds, and then turn back On.
For outlets that are Off prior to the Reboot command, they will turn On after
a delay of outletControlRebootOffTime seconds from when the command is issued.
0-n : Time in seconds until the Reboot command is issued
-1 : Cancel a pending outlet Reboot command
When read, returns -1 if no command is pending, or the current downcount in
seconds of a pending command. | |||||||||||||||||||||
| Cpdu2OutletControlPowerOnState | 1.3.6.1.4.1.232.165.7.5.2.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Determines the outlet state when power is applied to the unit. 1 : not restart at device startup 2 : should sequence back ON in line with outletControlSequenceTime 3 : should take the state the outlet had when power was lost. If the state was ON, should sequence back ON in line with outletControlSequenceTime.
| |||||||||||||||||||||
| Cpdu2OutletControlSequenceDelay | 1.3.6.1.4.1.232.165.7.5.2.1.6 | INTEGER (-1..99999) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..99999) · read-write · mandatory Time delay in seconds from when a Global Sequence On command is issued to when the command is executed on this outlet. This delay is also used as a power-on delay. Set to -1 to exclude this outlet from Global Sequence On commands. | |||||||||||||||||||||
| Cpdu2OutletControlRebootOffTime | 1.3.6.1.4.1.232.165.7.5.2.1.7 | INTEGER (-1..99999) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..99999) · read-write · mandatory Time delay in seconds that the outlet should remain in the Off state when executing a Reboot command. | |||||||||||||||||||||
| Cpdu2OutletControlSwitchable | 1.3.6.1.4.1.232.165.7.5.2.1.8 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Determines the outlet capability to be controlled On/Off from the communication channels. 1 : control On/Off enabled 2 : control On/Off disabled.
| |||||||||||||||||||||
| Cpdu2OutletControlShutoffDelay | 1.3.6.1.4.1.232.165.7.5.2.1.9 | INTEGER (-1..99999) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..99999) · read-write · mandatory Time delay in seconds that could be taken in account before shutting of the outlet. An application which need to shutoff properly an outlet will read this parameter first then write it to the command pdu2OutletControlOffCmd. | |||||||||||||||||||||
| Nhpdu | 1.3.6.1.4.1.232.165.9 | ||||||||||||||||||||
| NhpduIdent | 1.3.6.1.4.1.232.165.9.1 | ||||||||||||||||||||
| ShpduNumPhase | 1.3.6.1.4.1.232.165.9.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (0..100) · read-only · mandatory for 3 phases | |||||||||||||||||||||
| ThpduIdentTable | 1.3.6.1.4.1.232.165.9.1.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Indexed by 1 Hpdu unit. | |||||||||||||||||||||
| RhpduIdentEntry | 1.3.6.1.4.1.232.165.9.1.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The table entry containing the identifications of HPDU
| |||||||||||||||||||||
| ChpduIdentIndex | 1.3.6.1.4.1.232.165.9.1.2.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for the MpduIdentEntry table. Start with 1 | |||||||||||||||||||||
| ChpduManufacturer | 1.3.6.1.4.1.232.165.9.1.2.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU manufacturer. StringLength=[21] | |||||||||||||||||||||
| ChpduModel | 1.3.6.1.4.1.232.165.9.1.2.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU model, marketing name. StringLength=[40]. | |||||||||||||||||||||
| ChpduName | 1.3.6.1.4.1.232.165.9.1.2.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU name, descriptive name or hostname. StringLength=[16]. | |||||||||||||||||||||
| ChpduFirmwareVersion | 1.3.6.1.4.1.232.165.9.1.2.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU firmware version(s). StringLength=[12]. | |||||||||||||||||||||
| ChpduHardwareVersion | 1.3.6.1.4.1.232.165.9.1.2.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU hardware version. StringLength=[8]. | |||||||||||||||||||||
| ChpduPartNumber | 1.3.6.1.4.1.232.165.9.1.2.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Core PDU part number. StringLength=[21]. | |||||||||||||||||||||
| ChpduSerialNumber | 1.3.6.1.4.1.232.165.9.1.2.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PDU external serial number. StringLength=[21]. | |||||||||||||||||||||
| ChpduUUID | 1.3.6.1.4.1.232.165.9.1.2.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PDU's UUID equals PN add SN, canonical conversion. StringLength=[37]. | |||||||||||||||||||||
| ChpduType | 1.3.6.1.4.1.232.165.9.1.2.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PDU's Type: Delta, Wye, single, Wye+lowline. StringLength=[24]. | |||||||||||||||||||||
| ChpduPowerRating | 1.3.6.1.4.1.232.165.9.1.2.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PDU's Power Rating in KVA (Name Plate). Value is presented in 1/100 of the KVA. i.e. 1750 means 17.50 KVA | |||||||||||||||||||||
| ChpduInputRating | 1.3.6.1.4.1.232.165.9.1.2.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The PDU's Input Current Rating in A (Name Plate) | |||||||||||||||||||||
| ChpduRegionalNominalVoltage | 1.3.6.1.4.1.232.165.9.1.2.1.13 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory value is either America(208V), Japan(202V) or blank for International Model | |||||||||||||||||||||
| ChpduNumOutputBreakers | 1.3.6.1.4.1.232.165.9.1.2.1.14 | INTEGER (0..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..10) · read-only · mandatory The number of outlets with breakers of each hpdu. | |||||||||||||||||||||
| ChpduNumMonitoredOutlet | 1.3.6.1.4.1.232.165.9.1.2.1.15 | INTEGER (0..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..10) · read-only · mandatory The number of measured outlets (with CT, VT) of each hpdu. | |||||||||||||||||||||
| ChpduFanStatus | 1.3.6.1.4.1.232.165.9.1.2.1.16 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Report fan status: OK or FAIL | |||||||||||||||||||||
| ChpduTemperature | 1.3.6.1.4.1.232.165.9.1.2.1.17 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The internal temperature in Celcius. Value is presented in 1/10 of a degree i.e. 251 is 25.1. A value of -1 will be returned if the temperature is unable to be measured. | |||||||||||||||||||||
| NhpduInput | 1.3.6.1.4.1.232.165.9.2 | ||||||||||||||||||||
| ThpduInputTable | 1.3.6.1.4.1.232.165.9.2.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Indexed by hpduNumPhase. | |||||||||||||||||||||
| RhpduInputEntry | 1.3.6.1.4.1.232.165.9.2.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The Input table entry containing the voltage, current, PF, percent load, VA, Watts for the HPDU.
| |||||||||||||||||||||
| ChpduInputIndex | 1.3.6.1.4.1.232.165.9.2.1.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for the hpduInputEntry table. | |||||||||||||||||||||
| ChpduInputStatus | 1.3.6.1.4.1.232.165.9.2.1.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The overall status of the Input: off, on, problem. StringLength=[7]. | |||||||||||||||||||||
| ChpduInputBreakerRating | 1.3.6.1.4.1.232.165.9.2.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The rating of each hpdu Input in Ampere. | |||||||||||||||||||||
| ChpduInputVoltage | 1.3.6.1.4.1.232.165.9.2.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The measured Input voltage from the PDU meters in volts. Value is presented in 1/10 of the Volt i.e. 2095 is 209.5 V. A value of -1 will be returned if the voltage is unable to be measured. | |||||||||||||||||||||
| ChpduInputCurrent | 1.3.6.1.4.1.232.165.9.2.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The measured Input current from the PDU meters in amps. Value is presented in 1/100 of the Ampere i.e. 175 is 1.75 A. A value of -1 will be returned if the current is unable to be measured. | |||||||||||||||||||||
| ChpduInputPowerVA | 1.3.6.1.4.1.232.165.9.2.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The total Input Power measured in VA. A value of -1 will be returned if the power is unable to be calculated. | |||||||||||||||||||||
| ChpduInputPowerWatt | 1.3.6.1.4.1.232.165.9.2.1.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The total Input power measured in Watts. A value of -1 will be returned if the power is unable to be calculated. | |||||||||||||||||||||
| ChpduInputPowerFactor | 1.3.6.1.4.1.232.165.9.2.1.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Input power factor is presented in 1/100 of the unit i.e. 98 is 0.98. A value of -1 will be returned if the power factor is unable to be measured. | |||||||||||||||||||||
| ChpduInputWarningThreshold | 1.3.6.1.4.1.232.165.9.2.1.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Report the User-setting Input threshhold limit for Warning in percentage | |||||||||||||||||||||
| ChpduInputCriticalThreshold | 1.3.6.1.4.1.232.165.9.2.1.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Report the User-setting Input threshhold limit for Critical in percentage | |||||||||||||||||||||
| ChpduInputPowerWattHour | 1.3.6.1.4.1.232.165.9.2.1.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Support Billing Grade Energy Metering in Watt-Hour. A value of -1 will be returned if the power is unable to be calculated. | |||||||||||||||||||||
| ChpduInputTotalEnergySince | 1.3.6.1.4.1.232.165.9.2.1.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Display the date and time that starts to accumulate the per Load segment energy in WH. Date and Time can be set by user on GUI. | |||||||||||||||||||||
| ChpduInputEnergyMeteringTotalHours | 1.3.6.1.4.1.232.165.9.2.1.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Total hours of collecting measurement data. A value of -1 will be returned if the value is unable to be calculated. | |||||||||||||||||||||
| NhpduOutlet | 1.3.6.1.4.1.232.165.9.3 | ||||||||||||||||||||
| ThpduOutletTable | 1.3.6.1.4.1.232.165.9.3.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Indexed by hpduNumMonitoredOutlet and hpduNumPhase . So aggregate objects for each entry equal to (hpduNumMonitoredOutlet x hpduNumPhase). Start with 1. | |||||||||||||||||||||
| RhpduOutletEntry | 1.3.6.1.4.1.232.165.9.3.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The Outlet table entry containing the voltage, current, PF, percent load, VA, Watts for the Modular PDU. | |||||||||||||||||||||
| ChpduOutletIndex | 1.3.6.1.4.1.232.165.9.3.1.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for the hpduOutletEntry table. | |||||||||||||||||||||
| ChpduOutletStatus | 1.3.6.1.4.1.232.165.9.3.1.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The overall status of the breaker: off, on, problem. StringLength=[7]. | |||||||||||||||||||||
| ChpduOutletBreakerRating | 1.3.6.1.4.1.232.165.9.3.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The rating of each hpdu Outlet in Ampere. | |||||||||||||||||||||
| ChpduOutletPercentLoad | 1.3.6.1.4.1.232.165.9.3.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The hpdu's each Outlet load in percent of rated capacity. Value is presented in 1/10 of the percentage i.e. 125 is 12.5%. A value of -1 will be returned if the current is unable to be measured. | |||||||||||||||||||||
| ChpduOutletVoltage | 1.3.6.1.4.1.232.165.9.3.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The measured Outlet voltage from the PDU meters in volts. Value is presented in 1/10 of the Volt i.e. 2095 is 209.5 V. A value of -1 will be returned if the voltage is unable to be measured. | |||||||||||||||||||||
| ChpduOutletCurrent | 1.3.6.1.4.1.232.165.9.3.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The measured Outlet current from the PDU meters in amps. Value is presented in 1/100 of the Ampere i.e. 175 is 1.75 A. A value of -1 will be returned if the current is unable to be measured. | |||||||||||||||||||||
| ChpduOutletPowerVA | 1.3.6.1.4.1.232.165.9.3.1.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The total VA load (VI) measured on the PDU in VA. A value of -1 will be returned if the power is unable to be calculated. | |||||||||||||||||||||
| ChpduOutletPowerWatt | 1.3.6.1.4.1.232.165.9.3.1.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The total power load measured on the PDU in Watts. A value of -1 will be returned if the power is unable to be calculated. | |||||||||||||||||||||
| ChpduOutletPowerFactor | 1.3.6.1.4.1.232.165.9.3.1.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The power factor is presented in 1/100 of the unit i.e. 98 is 0.98. A value of -1 will be returned if the power factor is unable to be measured. | |||||||||||||||||||||
| ChpduOutletWarningThreshold | 1.3.6.1.4.1.232.165.9.3.1.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Report the User-set threshhold limit for Warning in percentage | |||||||||||||||||||||
| ChpduOutletCriticalThreshold | 1.3.6.1.4.1.232.165.9.3.1.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Report the User-set threshhold limit for Critical in percentage | |||||||||||||||||||||
| ChpduOutletPowerWattHour | 1.3.6.1.4.1.232.165.9.3.1.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Support Billing Grade Energy Metering in Watt-Hour. A value of -1 will be returned if the power is unable to be calculated. | |||||||||||||||||||||
| ChpduOutletTotalEnergySince | 1.3.6.1.4.1.232.165.9.3.1.1.13 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Display the date and time that starts to accumulate the per Load segment energy in WH. Date and Time can be set by user on GUI. | |||||||||||||||||||||
| ChpduOutletEnergyMeteringTotalHours | 1.3.6.1.4.1.232.165.9.3.1.1.14 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Total hours of collecting measurement data. A value of -1 will be returned if the value is unable to be calculated. | |||||||||||||||||||||
| Npdu3 | 1.3.6.1.4.1.232.165.11 | ||||||||||||||||||||
| Npdu3Ident | 1.3.6.1.4.1.232.165.11.1 | ||||||||||||||||||||
| Spdu3NumberPDU | 1.3.6.1.4.1.232.165.11.1.1 | INTEGER (1..2) | RO | mandatory | |||||||||||||||||
scalar · INTEGER (1..2) · read-only · mandatory The number of PDUs detected (in its daisy chain). | |||||||||||||||||||||
| Tpdu3IdentTable | 1.3.6.1.4.1.232.165.11.1.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to pdu3NumberPDU . | |||||||||||||||||||||
| Rpdu3IdentEntry | 1.3.6.1.4.1.232.165.11.1.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The ident table entry containing the name, model, manufacturer, firmware version, part number, etc.
| |||||||||||||||||||||
| Cpdu3IdentIndex | 1.3.6.1.4.1.232.165.11.1.2.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for the Pdu3IdentEntry table. | |||||||||||||||||||||
| Cpdu3Name | 1.3.6.1.4.1.232.165.11.1.2.1.2 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The string identify the device in daisy chain. Example PDU A. | |||||||||||||||||||||
| Cpdu3Model | 1.3.6.1.4.1.232.165.11.1.2.1.3 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The Device Model. | |||||||||||||||||||||
| Cpdu3Manufacturer | 1.3.6.1.4.1.232.165.11.1.2.1.4 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The Device Manufacturer Name (e.g. Hewlett-Packard). | |||||||||||||||||||||
| Cpdu3FirmwareVersion | 1.3.6.1.4.1.232.165.11.1.2.1.5 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The firmware revision level of the device. | |||||||||||||||||||||
| Cpdu3FirmwareVersionTimeStamp | 1.3.6.1.4.1.232.165.11.1.2.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Timestamp of when the PDU firmware was last updated | |||||||||||||||||||||
| Cpdu3PartNumber | 1.3.6.1.4.1.232.165.11.1.2.1.7 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The device part number. Example AF400A. | |||||||||||||||||||||
| Cpdu3SerialNumber | 1.3.6.1.4.1.232.165.11.1.2.1.8 | DisplayString (SIZE (0..63)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..63)) · read-only · mandatory The device serial number, 10- or 16-digit. | |||||||||||||||||||||
| Cpdu3Status | 1.3.6.1.4.1.232.165.11.1.2.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The overall status of the device. A value of OK(2) indicates the device is operating normally. A value of degraded(3) indicates the device is operating with warning indicators. A value of failed(4) indicates the device is operating with critical indicators.
| |||||||||||||||||||||
| Cpdu3Controllable | 1.3.6.1.4.1.232.165.11.1.2.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This object indicates whether or not the device is controllable.
| |||||||||||||||||||||
| Cpdu3InputPhaseCount | 1.3.6.1.4.1.232.165.11.1.2.1.11 | INTEGER (0..63) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..63) · read-only · mandatory The number of input phase on this pdu 1,2,3. | |||||||||||||||||||||
| Cpdu3GroupCount | 1.3.6.1.4.1.232.165.11.1.2.1.12 | INTEGER (0..63) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..63) · read-only · mandatory The number of groups (breakers) on this pdu. | |||||||||||||||||||||
| Cpdu3OutletCount | 1.3.6.1.4.1.232.165.11.1.2.1.13 | INTEGER (0..63) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..63) · read-only · mandatory The number of outlets in this PDU. | |||||||||||||||||||||
| Cpdu3MACAddress | 1.3.6.1.4.1.232.165.11.1.2.1.14 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The assigned MAC address for this PDU. | |||||||||||||||||||||
| Cpdu3IPv4Address | 1.3.6.1.4.1.232.165.11.1.2.1.15 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The current IPv4 Address. A value of 0.0.0.0 indicates an error or an unset option. | |||||||||||||||||||||
| Cpdu3IPv6Address | 1.3.6.1.4.1.232.165.11.1.2.1.16 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The current IPv6 Address. A vale of 0.0.0.0.0.0 indicates an error or an unset option. | |||||||||||||||||||||
| Tpdu3ConfigTable | 1.3.6.1.4.1.232.165.11.1.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to pdu3NumberPDU . | |||||||||||||||||||||
| Rpdu3ConfigEntry | 1.3.6.1.4.1.232.165.11.1.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Read Configuration data from the PDU being queried.
| |||||||||||||||||||||
| Cpdu3ConfigIndex | 1.3.6.1.4.1.232.165.11.1.3.1.1 | INTEGER (0..20) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..20) · read-only · mandatory The index of PDU configuration entry. | |||||||||||||||||||||
| Cpdu3ConfigSsh | 1.3.6.1.4.1.232.165.11.1.3.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Setting this OID to off(0) will disable the SSH conneciton. Setting this OID to on(1) will enable the SSH connection.
| |||||||||||||||||||||
| Cpdu3ConfigFtps | 1.3.6.1.4.1.232.165.11.1.3.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Setting this OID to off(0) will disable the FTPS connection. Setting this OID to on(1) will enable the FTPS connection.
| |||||||||||||||||||||
| Cpdu3ConfigHttp | 1.3.6.1.4.1.232.165.11.1.3.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Setting this OID to off(0) will disable the HTTP connection. Setting this OID to on(1) will enable the HTTP connection.
| |||||||||||||||||||||
| Cpdu3ConfigHttps | 1.3.6.1.4.1.232.165.11.1.3.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Setting this OID to off(0) will disable the HTTPS connection. Setting this OID to on(1) will enable the HTTPS connection.
| |||||||||||||||||||||
| Cpdu3ConfigIPv4IPv6Switch | 1.3.6.1.4.1.232.165.11.1.3.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Setting this OID to IPv4(1) will enable the IPv4 configuration. Setting this OID to IPv6(2) will enable the IPv6 configuration. Setting this OID to IPv4&IPv6(3) will enable both IPv4 and IPv6 configuration.
| |||||||||||||||||||||
| Cpdu3ConfigRedfishAPI | 1.3.6.1.4.1.232.165.11.1.3.1.7 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Setting this OID to off(0) will disable the Redfish API. Setting this OID to on(1) will enable the Redfish API.
| |||||||||||||||||||||
| Cpdu3ConfigOledDispalyOrientation | 1.3.6.1.4.1.232.165.11.1.3.1.8 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Indicates the intended physical orientation of OLED display. displayNormal(1) indicates normal orientation. displayReverse(2) indicates upside down orientation.
| |||||||||||||||||||||
| Cpdu3ConfigEnergyReset | 1.3.6.1.4.1.232.165.11.1.3.1.9 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Setting this OID to reset(2) will cause the device energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not supported this feature will respond to this OID with a value of notSupported(3). Attempts to set this OID in these models will fail.
| |||||||||||||||||||||
| Cpdu3ConfigNetworkManagementCardReset | 1.3.6.1.4.1.232.165.11.1.3.1.10 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Getting this OID will return noOperation(0). Getting this OID to reset(1) will reset NMC.
| |||||||||||||||||||||
| Cpdu3ConfigDaisyChainStatus | 1.3.6.1.4.1.232.165.11.1.3.1.11 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Setting this OID to daisychain(0) will enable daisychain mode.
| |||||||||||||||||||||
| Npdu3Input | 1.3.6.1.4.1.232.165.11.2 | ||||||||||||||||||||
| Tpdu3InputTable | 1.3.6.1.4.1.232.165.11.2.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to pdu3NumberPDU . | |||||||||||||||||||||
| Rpdu3InputEntry | 1.3.6.1.4.1.232.165.11.2.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The ident table entry containing the VA, Watts, WH, etc.
| |||||||||||||||||||||
| Cpdu3InputType | 1.3.6.1.4.1.232.165.11.2.1.1.1 | INTEGER | RO | mandatory | singlePhase(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory Type of input - single phase, split phase, three phase delta, or three phase wye.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3InputFrequency | 1.3.6.1.4.1.232.165.11.2.1.1.2 | INTEGER (0..2147483647) | RO | mandatory | 500 | ||||||||||||||||
column · INTEGER (0..2147483647) · read-only · mandatory The measured input frequency from the PDU meters in tenths of Hz. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3InputFrequencyStatus | 1.3.6.1.4.1.232.165.11.2.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured input frequency relative to the nominal frequency and the admitted tolerance.
| |||||||||||||||||||||
| Cpdu3InputPowerVA | 1.3.6.1.4.1.232.165.11.2.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A total input VA of all phases. Units are 0.001 VA. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPowerWatts | 1.3.6.1.4.1.232.165.11.2.1.1.5 | INTEGER | RO | mandatory | 154 | ||||||||||||||||
column · INTEGER · read-only · mandatory A total input Watts of all phases. Units are 0.001 Watts. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3InputTotalEnergy | 1.3.6.1.4.1.232.165.11.2.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A total input Watt-Hour value for all phases. Units are KWh. This value is accumulated since PDU in service. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPowerWattHourTimer | 1.3.6.1.4.1.232.165.11.2.1.1.7 | DisplayString (SIZE (0..22)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..22)) · read-only · mandatory A Timestamp of when the Total Input WH was last reset. | |||||||||||||||||||||
| Cpdu3InputResettableEnergy | 1.3.6.1.4.1.232.165.11.2.1.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A total input Watt-Hour value for all phases. Units are 0.001 Wh. This value can be reset to 0 using GUI. In that case, the pdu3InputPowerWattHourTimer will be reset as well A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPowerFactor | 1.3.6.1.4.1.232.165.11.2.1.1.9 | INTEGER | RO | mandatory | 98 | ||||||||||||||||
column · INTEGER · read-only · mandatory An input PF value. Units are in thousandths, for example a power factor
of 0.958 would be returned as 958, and 0.92 would be returned as 920.
A negative value indicates that this object is not available.Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3InputPowerVAR | 1.3.6.1.4.1.232.165.11.2.1.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory An input VAR value. Units are 0.001 VAR. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Tpdu3InputPhaseTable | 1.3.6.1.4.1.232.165.11.2.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to number of PDUs (pdu3NumberPDU) and number of input phase (pdu3InputPhaseCount). | |||||||||||||||||||||
| Rpdu3InputPhaseEntry | 1.3.6.1.4.1.232.165.11.2.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The input table entry containing the voltage, current, frequency, power for each phase. Entries are given with number of pdu and number of input phase 1, 2, or 3. | |||||||||||||||||||||
| Cpdu3InputPhaseIndex | 1.3.6.1.4.1.232.165.11.2.2.1.1 | INTEGER (0..100) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for the Pdu3InputEntry table. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3InputPhaseVoltageMeasType | 1.3.6.1.4.1.232.165.11.2.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Value indicates what input voltage is being measured in this table row - single phase voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2, phase 2 to phase 3, or phase 3 to phase 1.
| |||||||||||||||||||||
| Cpdu3InputPhaseVoltage | 1.3.6.1.4.1.232.165.11.2.2.1.3 | INTEGER | RO | mandatory | 2298 | ||||||||||||||||
column · INTEGER · read-only · mandatory An input voltage measurement value. Return value is divided by 10. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3InputPhaseVoltageThStatus | 1.3.6.1.4.1.232.165.11.2.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured input voltage relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdu3InputPhaseVoltageThLowerWarning | 1.3.6.1.4.1.232.165.11.2.2.1.5 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Lower warning threshold. Return value is divided by 10. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPhaseVoltageThLowerCritical | 1.3.6.1.4.1.232.165.11.2.2.1.6 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Lower critical threshold. Return value is divided by 10. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPhaseVoltageThUpperWarning | 1.3.6.1.4.1.232.165.11.2.2.1.7 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Upper warning threshold. Return value is divided by 10. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPhaseVoltageThUpperCritical | 1.3.6.1.4.1.232.165.11.2.2.1.8 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Upper critical threshold. Return value is divided by 10. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPhaseCurrentMeasType | 1.3.6.1.4.1.232.165.11.2.2.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Which input wire is being measured in this table row - single phase, neutral, phase 1, phase 2, or phase 3.
| |||||||||||||||||||||
| Cpdu3InputPhaseCurrentRating | 1.3.6.1.4.1.232.165.11.2.2.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Rated current capacity of the input. A negative value indicates that the hardware current capacity is unknown. Return value is divided by 100. | |||||||||||||||||||||
| Cpdu3InputPhaseCurrent | 1.3.6.1.4.1.232.165.11.2.2.1.11 | INTEGER | RO | mandatory | 65 | ||||||||||||||||
column · INTEGER · read-only · mandatory An input current measurement value. Return value is divided by 100. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3InputPhaseCurrentThStatus | 1.3.6.1.4.1.232.165.11.2.2.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured input current relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdu3InputPhaseCurrentThLowerWarning | 1.3.6.1.4.1.232.165.11.2.2.1.13 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Lower warning threshold. Return value is divided by 100. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPhaseCurrentThLowerCritical | 1.3.6.1.4.1.232.165.11.2.2.1.14 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Lower critical threshold. Return value is divided by 100. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPhaseCurrentThUpperWarning | 1.3.6.1.4.1.232.165.11.2.2.1.15 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Upper warning threshold. Return value is divided by 100. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPhaseCurrentThUpperCritical | 1.3.6.1.4.1.232.165.11.2.2.1.16 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Upper critical threshold. Return value is divided by 100. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPhaseCurrentPercentLoad | 1.3.6.1.4.1.232.165.11.2.2.1.17 | INTEGER | RO | mandatory | 20 | ||||||||||||||||
column · INTEGER · read-only · mandatory Current percent load, based on the rated current capacity. Units are percentage, for example 80.9 % will be returned as 809. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3InputPhasePowerMeasType | 1.3.6.1.4.1.232.165.11.2.2.1.18 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Which input wire is being measured in this table row - single phase, neutral, phase 1, phase 2, or phase 3.
| |||||||||||||||||||||
| Cpdu3InputPhasePowerVA | 1.3.6.1.4.1.232.165.11.2.2.1.19 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory An input VA value. Units are VA. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPhasePowerWatts | 1.3.6.1.4.1.232.165.11.2.2.1.20 | INTEGER | RO | mandatory | 154 | ||||||||||||||||
column · INTEGER · read-only · mandatory An input Watts value. Units are Watts. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3InputPhasePowerWattHour | 1.3.6.1.4.1.232.165.11.2.2.1.21 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A kWatt-Hour value for each Input phase. Units are kWh. This value can be reset to 0 using GUI. In that case, the pdu3InputPhasePowerWattHourTimer will be reset as well A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPhasePowerWattHourTimer | 1.3.6.1.4.1.232.165.11.2.2.1.22 | DisplayString (SIZE (0..22)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..22)) · read-only · mandatory Timestamp of when input phase kWatt-hours (kWh) was last reset. | |||||||||||||||||||||
| Cpdu3InputPhasePowerFactor | 1.3.6.1.4.1.232.165.11.2.2.1.23 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory An input PF value. Return value is divided by 100, for example a power factor of 0.95 would be returned as 95. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3InputPhasePowerVAR | 1.3.6.1.4.1.232.165.11.2.2.1.24 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory An input VA Reactive value. Units are in VAR. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Npdu3Group | 1.3.6.1.4.1.232.165.11.3 | ||||||||||||||||||||
| Tpdu3GroupTable | 1.3.6.1.4.1.232.165.11.3.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to number of PDUs and number of breakers (pdu3GroupCount). | |||||||||||||||||||||
| Rpdu3GroupEntry | 1.3.6.1.4.1.232.165.11.3.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The input table entry containing the name, voltages, currents, power, etc.
| |||||||||||||||||||||
| Cpdu3GroupIndex | 1.3.6.1.4.1.232.165.11.3.1.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for the Pdu3GroupEntry table. | |||||||||||||||||||||
| Cpdu3GroupName | 1.3.6.1.4.1.232.165.11.3.1.1.2 | DisplayString (SIZE (1..31)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (1..31)) · read-only · mandatory A descriptive name for the group. | |||||||||||||||||||||
| Cpdu3GroupType | 1.3.6.1.4.1.232.165.11.3.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The type of the group. (5) has no breaker
| |||||||||||||||||||||
| Cpdu3GroupVoltageMeasType | 1.3.6.1.4.1.232.165.11.3.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Value indicates what input voltage is being measured in this table row - single phase voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2, phase 2 to phase 3, or phase 3 to phase 1.
| |||||||||||||||||||||
| Cpdu3GroupVoltage | 1.3.6.1.4.1.232.165.11.3.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Return value is divided by 10 to get one decimal point, unit is in Volt. | |||||||||||||||||||||
| Cpdu3GroupVoltageThStatus | 1.3.6.1.4.1.232.165.11.3.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured group voltage relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdu3GroupVoltageThLowerWarning | 1.3.6.1.4.1.232.165.11.3.1.1.7 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Lower warning threshold. Return value is divided by 10 to get one decimal point, unit is in Volt. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3GroupVoltageThLowerCritical | 1.3.6.1.4.1.232.165.11.3.1.1.8 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Lower critical threshold. Return value is divided by 10 to get one decimal point, unit is in Volt. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3GroupVoltageThUpperWarning | 1.3.6.1.4.1.232.165.11.3.1.1.9 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Upper warning threshold. Return value is divided by 10 to get one decimal point, unit is in Volt. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3GroupVoltageThUpperCritical | 1.3.6.1.4.1.232.165.11.3.1.1.10 | INTEGER (-1..500000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..500000) · read-only · mandatory Upper critical threshold. Return value is divided by 10 to get one decimal point, unit is in Volt. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3groupCurrentRating | 1.3.6.1.4.1.232.165.11.3.1.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Rated current capacity of the group. Return value is divided by 100 to get two decimal points,
unit is in Amps. A negative value indicates that the hardware current capacity is unknown (it
will always be unknown for custom groups). | |||||||||||||||||||||
| Cpdu3GroupCurrent | 1.3.6.1.4.1.232.165.11.3.1.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A group current measurement value. Return value is divided by 100 to get two decimal points. | |||||||||||||||||||||
| Cpdu3GroupCurrentThStatus | 1.3.6.1.4.1.232.165.11.3.1.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured group current relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdu3GroupCurrentThLowerWarning | 1.3.6.1.4.1.232.165.11.3.1.1.14 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Lower warning threshold. Return value is divided by 100 to get two decimal points. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3GroupCurrentThLowerCritical | 1.3.6.1.4.1.232.165.11.3.1.1.15 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Lower critical threshold. Return value is divided by 100 to get two decimal points. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3GroupCurrentThUpperWarning | 1.3.6.1.4.1.232.165.11.3.1.1.16 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Upper warning threshold. Return value is divided by 100 to get two decimal points. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3GroupCurrentThUpperCritical | 1.3.6.1.4.1.232.165.11.3.1.1.17 | INTEGER (-1..100000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..100000) · read-only · mandatory Upper critical threshold. Return value is divided by 100 to get two decimal points. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3GroupCurrentPercentLoad | 1.3.6.1.4.1.232.165.11.3.1.1.18 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Current percent load, based on the rated current capacity. Units are percentage, for example 80.9 % will be returned as 809. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3GroupPowerVA | 1.3.6.1.4.1.232.165.11.3.1.1.19 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A group VA value. Units are VA. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3GroupPowerWatts | 1.3.6.1.4.1.232.165.11.3.1.1.20 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A group power value. Units are Watts. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3GroupPowerWattHour | 1.3.6.1.4.1.232.165.11.3.1.1.21 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory An energy consumption value for each load segment. Units are kWh. This value can be reset to 0 using GUI. In that case, the pdu3GroupPowerWattHourTimer will be reset as well. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3GroupPowerWattHourTimer | 1.3.6.1.4.1.232.165.11.3.1.1.22 | DisplayString (SIZE (0..22)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..22)) · read-only · mandatory Timestamp when group kilo Watt-hours (group kWh) is reset. | |||||||||||||||||||||
| Cpdu3GroupPowerFactor | 1.3.6.1.4.1.232.165.11.3.1.1.23 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A group PF value. Return value is divided by 100, for example a power factor of 0.95 would be returned as 95. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3GroupPowerVAR | 1.3.6.1.4.1.232.165.11.3.1.1.24 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A measurement for group/load segment power reactive. Units are VAR. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3GroupOutletCount | 1.3.6.1.4.1.232.165.11.3.1.1.25 | INTEGER (0..63) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..63) · read-only · mandatory The number of outlets in each group (breaker). | |||||||||||||||||||||
| Cpdu3GroupBreakerStatus | 1.3.6.1.4.1.232.165.11.3.1.1.26 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Only applicable to groups with breaker. Indicates whether a breaker is turned off or on.
| |||||||||||||||||||||
| Npdu3Environment | 1.3.6.1.4.1.232.165.11.4 | ||||||||||||||||||||
| Tpdu3EnvProbeTable | 1.3.6.1.4.1.232.165.11.4.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of environment probe (1 per PDU) for temperature, humidity, and contacts. The number of entries is given by number of PDUs in daisy chain. | |||||||||||||||||||||
| Rpdu3EnvProbeEntry | 1.3.6.1.4.1.232.165.11.4.1.1 | NA | mandatory | ||||||||||||||||||
| Cpdu3TemperatureScale | 1.3.6.1.4.1.232.165.11.4.1.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Scale used to return temperature objects.
| |||||||||||||||||||||
| Cpdu3TemperatureCount | 1.3.6.1.4.1.232.165.11.4.1.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Max number of temperature measurements (1 per probe). | |||||||||||||||||||||
| Cpdu3HumidityCount | 1.3.6.1.4.1.232.165.11.4.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Max number of humidity measurements (1 per probe). | |||||||||||||||||||||
| Cpdu3ContactCount | 1.3.6.1.4.1.232.165.11.4.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Max number of contact sensors (1 per probe). | |||||||||||||||||||||
| Tpdu3TemperatureTable | 1.3.6.1.4.1.232.165.11.4.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of temperature probe measurements. The number of entries are given by number of pdu and pdu3TemperatureCount. | |||||||||||||||||||||
| Rpdu3TemperatureEntry | 1.3.6.1.4.1.232.165.11.4.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry for a temperature measurement. | |||||||||||||||||||||
| Cpdu3TemperatureIndex | 1.3.6.1.4.1.232.165.11.4.2.1.1 | INTEGER (1..2) | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER (1..2) · read-only · mandatory A unique value for each temperature probe measurement. Its value ranges from 1 to temperatureCount. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3TemperatureName | 1.3.6.1.4.1.232.165.11.4.2.1.2 | DisplayString (SIZE (1..31)) | RO | mandatory | | ||||||||||||||||
column · DisplayString (SIZE (1..31)) · read-only · mandatory A descriptive name for the temperature probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3TemperatureProbeStatus | 1.3.6.1.4.1.232.165.11.4.2.1.3 | INTEGER | RO | mandatory | disconnected(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether a probe is connected or not.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3TemperatureValue | 1.3.6.1.4.1.232.165.11.4.2.1.4 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory Units are in tenths of a degree (either Fahrenheit or Celsius). Return value is divided by 10 to get degrees. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3TemperatureThStatus | 1.3.6.1.4.1.232.165.11.4.2.1.5 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured temperature relative to the configured thresholds.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3TemperatureThLowerWarning | 1.3.6.1.4.1.232.165.11.4.2.1.6 | INTEGER (-1..150000) | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER (-1..150000) · read-only · mandatory Lower warning threshold. Return value is divided by 10 to get degree. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3TemperatureThLowerCritical | 1.3.6.1.4.1.232.165.11.4.2.1.7 | INTEGER (-1..150000) | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER (-1..150000) · read-only · mandatory Lower critical threshold. Return value is divided by 10 to get degree. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3TemperatureThUpperWarning | 1.3.6.1.4.1.232.165.11.4.2.1.8 | INTEGER (-1..150000) | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER (-1..150000) · read-only · mandatory Upper warning threshold. Return value is divided by 10 to get degree. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3TemperatureThUpperCritical | 1.3.6.1.4.1.232.165.11.4.2.1.9 | INTEGER (-1..150000) | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER (-1..150000) · read-only · mandatory Upper critical threshold. Return value is divided by 10 to get degree. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tpdu3HumidityTable | 1.3.6.1.4.1.232.165.11.4.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of humidity probe measurements. The number of entries are given by number of pdu and pdu3HumidityCount. | |||||||||||||||||||||
| Rpdu3HumidityEntry | 1.3.6.1.4.1.232.165.11.4.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry for a humidity measurement. | |||||||||||||||||||||
| Cpdu3HumidityIndex | 1.3.6.1.4.1.232.165.11.4.3.1.1 | INTEGER (1..2) | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER (1..2) · read-only · mandatory A unique value for each humidity probe measurement. Its value ranges from 1 to pdu3HumidityCount per pdu. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3HumidityName | 1.3.6.1.4.1.232.165.11.4.3.1.2 | DisplayString (SIZE (1..31)) | RO | mandatory | | ||||||||||||||||
column · DisplayString (SIZE (1..31)) · read-only · mandatory A descriptive name for the humidity probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3HumidityProbeStatus | 1.3.6.1.4.1.232.165.11.4.3.1.3 | INTEGER | RO | mandatory | disconnected(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether a probe is connected or not.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3HumidityValue | 1.3.6.1.4.1.232.165.11.4.3.1.4 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory Units are tenths of a percent relative humidity. Return value is divided by 10 to get %RH. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3HumidityThStatus | 1.3.6.1.4.1.232.165.11.4.3.1.5 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured humidity relative to the configured thresholds.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3HumidityThLowerWarning | 1.3.6.1.4.1.232.165.11.4.3.1.6 | INTEGER (-1..1000) | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER (-1..1000) · read-only · mandatory Lower warning threshold. Return value is divided by 10 to get %RH. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3HumidityThLowerCritical | 1.3.6.1.4.1.232.165.11.4.3.1.7 | INTEGER (-1..1000) | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER (-1..1000) · read-only · mandatory Lower critical threshold. Return value is divided by 10 to get %RH. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3HumidityThUpperWarning | 1.3.6.1.4.1.232.165.11.4.3.1.8 | INTEGER (-1..1000) | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER (-1..1000) · read-only · mandatory Upper warning threshold. Return value is divided by 10 to get %RH. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3HumidityThUpperCritical | 1.3.6.1.4.1.232.165.11.4.3.1.9 | INTEGER (-1..1000) | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER (-1..1000) · read-only · mandatory Upper critical threshold. Return value is divided by 10 to get %RH. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tpdu3ContactTable | 1.3.6.1.4.1.232.165.11.4.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of contact sensors. The number of entries are given by number of pdu and pdu3ContactCount. | |||||||||||||||||||||
| Rpdu3ContactEntry | 1.3.6.1.4.1.232.165.11.4.4.1 | NA | mandatory | ||||||||||||||||||
| Cpdu3ContactIndex | 1.3.6.1.4.1.232.165.11.4.4.1.1 | INTEGER (1..3) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..3) · read-only · mandatory A unique value for each contact sensor. Its value ranges from 1 to contactCount. | |||||||||||||||||||||
| Cpdu3ContactName | 1.3.6.1.4.1.232.165.11.4.4.1.2 | DisplayString (SIZE (1..31)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (1..31)) · read-only · mandatory A descriptive name for the contact sensor. | |||||||||||||||||||||
| Cpdu3ContactProbeStatus | 1.3.6.1.4.1.232.165.11.4.4.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether a probe is connected or not. Will not be returned if the contact sensor is internal to the ePDU, in that case only contactState should be read.
| |||||||||||||||||||||
| Cpdu3ContactState | 1.3.6.1.4.1.232.165.11.4.4.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The state of the contact sensor.
| |||||||||||||||||||||
| Npdu3Outlet | 1.3.6.1.4.1.232.165.11.5 | ||||||||||||||||||||
| Tpdu3OutletTable | 1.3.6.1.4.1.232.165.11.5.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to Number of PDU (pdu3IdentIndex) and Number of outlet per PDU (pdu3OutletIndex). | |||||||||||||||||||||
| Rpdu3OutletEntry | 1.3.6.1.4.1.232.165.11.5.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The Outlet table entry containing the type, voltage, current etc. | |||||||||||||||||||||
| Cpdu3OutletIndex | 1.3.6.1.4.1.232.165.11.5.1.1.1 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory Index for each outlet, value from 1 to the number of outlets per PDU. | |||||||||||||||||||||
| Cpdu3OutletName | 1.3.6.1.4.1.232.165.11.5.1.1.2 | DisplayString (SIZE (1..31)) | RO | mandatory | OUTLET 1 | ||||||||||||||||
column · DisplayString (SIZE (1..31)) · read-only · mandatory A descriptive name for the outlet. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3OutletType | 1.3.6.1.4.1.232.165.11.5.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Type of this outlet - C13, C19.
| |||||||||||||||||||||
| Cpdu3OutletCurrentRating | 1.3.6.1.4.1.232.165.11.5.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Rated current capacity of this outlet. Return value is divided by 100 to get amps. A negative value indicates that the hardware current capacity is unknown. | |||||||||||||||||||||
| Cpdu3OutletCurrent | 1.3.6.1.4.1.232.165.11.5.1.1.5 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory A outlet current measurement value. Return value is divided by 100 to get amps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3OutletActivePowerThStatus | 1.3.6.1.4.1.232.165.11.5.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Status of the measured outlet active power relative to the configured thresholds.
| |||||||||||||||||||||
| Cpdu3OutletActivePowerThLowerWarning | 1.3.6.1.4.1.232.165.11.5.1.1.7 | INTEGER (-1..10000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..10000) · read-only · mandatory Lower warning threshold. Units are Watts(W). A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3OutletActivePowerThLowerCritical | 1.3.6.1.4.1.232.165.11.5.1.1.8 | INTEGER (-1..10000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..10000) · read-only · mandatory Lower critical threshold. Units are Watts(W). A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3OutletActivePowerThUpperWarning | 1.3.6.1.4.1.232.165.11.5.1.1.9 | INTEGER (-1..10000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..10000) · read-only · mandatory Upper warning threshold. Units are Watts(W). A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3OutletActivePowerThUpperCritical | 1.3.6.1.4.1.232.165.11.5.1.1.10 | INTEGER (-1..10000) | RO | mandatory | |||||||||||||||||
column · INTEGER (-1..10000) · read-only · mandatory Upper critical threshold. Units are Watts(W). A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3OutletCurrentPercentLoad | 1.3.6.1.4.1.232.165.11.5.1.1.11 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory Current percent load, based on the rated current capacity. Units are percentage, for example 80.5% will be returned as 805. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3OutletVA | 1.3.6.1.4.1.232.165.11.5.1.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A outlet power VA value. Units are VA. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3OutletWatts | 1.3.6.1.4.1.232.165.11.5.1.1.13 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory A outlet power in Watts value. Units are Watts. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3OutletWh | 1.3.6.1.4.1.232.165.11.5.1.1.14 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory An energy in kWatt-Hour value for each outlet. Units are kWh.
This object is writable so that it can be reset to 0. When it is
written to, the pdu3OutletWhTimer will be reset updated as well
A negative value indicates that this object is not available. | |||||||||||||||||||||
| Cpdu3OutletWhTimer | 1.3.6.1.4.1.232.165.11.5.1.1.15 | DisplayString (SIZE (0..22)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..22)) · read-only · mandatory Timestamp (date and time) of outlet energy in kWh is reset. | |||||||||||||||||||||
| Cpdu3OutletPowerFactor | 1.3.6.1.4.1.232.165.11.5.1.1.16 | INTEGER | RO | mandatory | 100 | ||||||||||||||||
column · INTEGER · read-only · mandatory An outlet PF value. Return value is divided by 100, for example a power factor of 0.95 would be returned as 95. A negative value indicates that this object is not available. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3OutletVAR | 1.3.6.1.4.1.232.165.11.5.1.1.17 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory An outlet power reactive in VAR value. Units are VAR. A negative value indicates that this object is not available. | |||||||||||||||||||||
| Tpdu3OutletControlTable | 1.3.6.1.4.1.232.165.11.5.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Aggregate Object with number of entries equal to Number of PDU (pdu3IdentIndex) and Number of outlets per PDU (pdu3OutletIndex). | |||||||||||||||||||||
| Rpdu3OutletControlEntry | 1.3.6.1.4.1.232.165.11.5.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The Outlet table entry containing the type, voltage, current etc. | |||||||||||||||||||||
| Cpdu3OutletControlStatus | 1.3.6.1.4.1.232.165.11.5.2.1.1 | INTEGER | RO | mandatory | on(2) | ||||||||||||||||
column · INTEGER · read-only · mandatory current state of a control outlet.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cpdu3OutletControlOffCmd | 1.3.6.1.4.1.232.165.11.5.2.1.2 | INTEGER (-1..99999) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..99999) · read-write · mandatory When write, once issued, the outlet will turn Off immediately.
0-n: Time in seconds until the outlet command is issued
-1: Cancel a pending outlet Off command
When read, returns -1 if no command is pending, or the current downcount in
seconds of a pending command. | |||||||||||||||||||||
| Cpdu3OutletControlOnCmd | 1.3.6.1.4.1.232.165.11.5.2.1.3 | INTEGER (-1..99999) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..99999) · read-write · mandatory When write, once issued, the outlet will turn On immediately.
0-n: Time in seconds until the outlet command is issued
-1: Cancel a pending outlet On command
When read, returns -1 if no command is pending, or the current downcount in
seconds of a pending command. | |||||||||||||||||||||
| Cpdu3OutletControlRebootCmd | 1.3.6.1.4.1.232.165.11.5.2.1.4 | INTEGER (-1..99999) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..99999) · read-write · mandatory When write, for outlets that are On prior to this Reboot command, they will
switch Off immediately when the command is issued, remain Off for
outletControlRebootOffTime seconds, and then turn back On.
For outlets that are Off prior to the Reboot command, they will turn On after
a delay of outletControlRebootOffTime seconds from when the command is issued.
0-n : Time in seconds until the Reboot command is issued
-1 : Cancel a pending outlet Reboot command
When read, returns -1 if no command is pending, or the current downcount in
seconds of a pending command. | |||||||||||||||||||||
| Cpdu3OutletControlPowerOnState | 1.3.6.1.4.1.232.165.11.5.2.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Determines the outlet state when power is applied to the unit. 1 : not restart at device startup 2 : should sequence back ON in line with outletControlSequenceTime 3 : should take the state the outlet had when power was lost. If the state was ON, should sequence back ON in line with outletControlSequenceTime.
| |||||||||||||||||||||
| Cpdu3OutletControlSequenceDelay | 1.3.6.1.4.1.232.165.11.5.2.1.6 | INTEGER (-1..99999) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..99999) · read-write · mandatory Time delay in seconds from when a Global Sequence On command is issued to when the command is executed on this outlet. This delay is also used as a power-on delay. Set to -1 to exclude this outlet from Global Sequence On commands. | |||||||||||||||||||||
| Cpdu3OutletControlRebootOffTime | 1.3.6.1.4.1.232.165.11.5.2.1.7 | INTEGER (-1..99999) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..99999) · read-write · mandatory Time delay in seconds that the outlet should remain in the Off state when executing a Reboot command. | |||||||||||||||||||||
| Cpdu3OutletControlSwitchable | 1.3.6.1.4.1.232.165.11.5.2.1.8 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Determines the outlet capability to be controlled On/Off from the communication channels. 1 : control On/Off enabled 2 : control On/Off disabled.
| |||||||||||||||||||||
| Cpdu3OutletControlShutoffDelay | 1.3.6.1.4.1.232.165.11.5.2.1.9 | INTEGER (-1..99999) | RW | mandatory | |||||||||||||||||
column · INTEGER (-1..99999) · read-write · mandatory Time delay in seconds that could be taken in account before shutting of the outlet. An application which need to shutoff properly an outlet will read this parameter first then write it to the command pdu3OutletControlOffCmd. | |||||||||||||||||||||
Traps / Notifications
- deviceTrapInitialization
1.3.6.1.4.1.232.165.0.6 - trapCleared
1.3.6.1.4.1.232.165.0.4 - trapCritical
1.3.6.1.4.1.232.165.0.1 - trapInformation
1.3.6.1.4.1.232.165.0.3 - trapTest
1.3.6.1.4.1.232.165.0.5 - trapWarning
1.3.6.1.4.1.232.165.0.2