GUDEADS-ESB7214-MIB
Gude Analog- und Digitalsysteme GmbHExpert Power Control 7214 MIB
snmptranslate -m GUDEADS-ESB7214-MIB -Tpsnmpwalk -v2c -c <community> -m GUDEADS-ESB7214-MIB <host> 1.3.6.1.4.1.28507Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Igudeads | 1.3.6.1.4.1.28507 | ||||||||||||||||||||
identity Expert Power Control 7214 MIB | |||||||||||||||||||||
| NgadsESB7214 | 1.3.6.1.4.1.28507.67 | ||||||||||||||||||||
| Nesb7214Objects | 1.3.6.1.4.1.28507.67.1 | ||||||||||||||||||||
| Nesb7214CommonConfig | 1.3.6.1.4.1.28507.67.1.1 | ||||||||||||||||||||
| Nesb7214SNMPaccess | 1.3.6.1.4.1.28507.67.1.1.1 | ||||||||||||||||||||
| Sesb7214TrapCtrl | 1.3.6.1.4.1.28507.67.1.1.1.1 | Integer32 (0..3) | RW | 0 | |||||||||||||||||
scalar · Integer32 (0..3) · read-write · current 0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3 Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tesb7214TrapIPTable | 1.3.6.1.4.1.28507.67.1.1.1.2 | NA | |||||||||||||||||||
table · not-accessible · current list of all Trap receiver | |||||||||||||||||||||
| Resb7214TrapIPEntry | 1.3.6.1.4.1.28507.67.1.1.1.2.1 | NA | |||||||||||||||||||
row · not-accessible · current an entry containing management informations regarding the list of trap receivers
| |||||||||||||||||||||
| Cesb7214TrapIPIndex | 1.3.6.1.4.1.28507.67.1.1.1.2.1.1 | Integer32 (1..8) | RO | 1 | |||||||||||||||||
column · Integer32 (1..8) · read-only · current A unique value, greater than zero, for each receiver slot. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214TrapAddr | 1.3.6.1.4.1.28507.67.1.1.1.2.1.2 | OCTET STRING (SIZE (0..99)) | RW | | |||||||||||||||||
column · OCTET STRING (SIZE (0..99)) · read-write · current DNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nesb7214DeviceConfig | 1.3.6.1.4.1.28507.67.1.2 | ||||||||||||||||||||
| Nesb7214IntActors | 1.3.6.1.4.1.28507.67.1.3 | ||||||||||||||||||||
| Nesb7214relayports | 1.3.6.1.4.1.28507.67.1.3.1 | ||||||||||||||||||||
| Sesb7214portNumber | 1.3.6.1.4.1.28507.67.1.3.1.1 | Integer32 (1..12) | RO | 1 | |||||||||||||||||
scalar · Integer32 (1..12) · read-only · current The number of Relay Ports Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tesb7214portTable | 1.3.6.1.4.1.28507.67.1.3.1.2 | NA | |||||||||||||||||||
table · not-accessible · current list of all ENC Relay Ports | |||||||||||||||||||||
| Resb7214portEntry | 1.3.6.1.4.1.28507.67.1.3.1.2.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry containing management information applicable to a particular relay port.
| |||||||||||||||||||||
| Cesb7214PortIndex | 1.3.6.1.4.1.28507.67.1.3.1.2.1.1 | Integer32 (1..12) | RO | 1 | |||||||||||||||||
column · Integer32 (1..12) · read-only · current A unique value, greater than zero, for each Relay Port. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214PortName | 1.3.6.1.4.1.28507.67.1.3.1.2.1.2 | OCTET STRING (SIZE (0..15)) | RW | Output Port | |||||||||||||||||
column · OCTET STRING (SIZE (0..15)) · read-write · current A textual string containing name of a Relay Port. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214PortState | 1.3.6.1.4.1.28507.67.1.3.1.2.1.3 | INTEGER | RW | off(0) | |||||||||||||||||
column · INTEGER · read-write · current current state of a Relay Port
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214PortSwitchCount | 1.3.6.1.4.1.28507.67.1.3.1.2.1.4 | Integer32 | RO | 2 | |||||||||||||||||
column · Integer32 · read-only · current The total number of switch actions ocurred on a Relay Port. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214PortStartupMode | 1.3.6.1.4.1.28507.67.1.3.1.2.1.5 | INTEGER | RW | laststate(2) | |||||||||||||||||
column · INTEGER · read-write · current set Mode of startup sequence (off, on , remember last state)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214PortStartupDelay | 1.3.6.1.4.1.28507.67.1.3.1.2.1.6 | Integer32 | RW | 0 | |||||||||||||||||
column · Integer32 · read-write · current Delay in sec for startup action
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214PortRepowerTime | 1.3.6.1.4.1.28507.67.1.3.1.2.1.7 | Integer32 (0..65535) | RW | 0 | |||||||||||||||||
column · Integer32 (0..65535) · read-write · current Delay in sec for repower port after switching off
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214PortResetDuration | 1.3.6.1.4.1.28507.67.1.3.1.2.1.8 | Integer32 (0..65535) | RW | 10 | |||||||||||||||||
column · Integer32 (0..65535) · read-write · current Delay in sec for turning Port on again after Reset action
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nesb7214ExtActors | 1.3.6.1.4.1.28507.67.1.4 | ||||||||||||||||||||
| Nesb7214IntSensors | 1.3.6.1.4.1.28507.67.1.5 | ||||||||||||||||||||
| Nesb7214Inputs | 1.3.6.1.4.1.28507.67.1.5.6 | ||||||||||||||||||||
| Sesb7214ActiveInputs | 1.3.6.1.4.1.28507.67.1.5.6.1 | Unsigned32 (1..12) | RO | 1 | |||||||||||||||||
scalar · Unsigned32 (1..12) · read-only · current Number of suppported Input Channels. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tesb7214InputTable | 1.3.6.1.4.1.28507.67.1.5.6.2 | NA | |||||||||||||||||||
| Resb7214InputEntry | 1.3.6.1.4.1.28507.67.1.5.6.2.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| Cesb7214InputIndex | 1.3.6.1.4.1.28507.67.1.5.6.2.1.1 | Integer32 (1..12) | RO | 1 | |||||||||||||||||
column · Integer32 (1..12) · read-only · current Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214Input | 1.3.6.1.4.1.28507.67.1.5.6.2.1.2 | INTEGER | RO | lo(0) | |||||||||||||||||
column · INTEGER · read-only · current Input state of device
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214InputName | 1.3.6.1.4.1.28507.67.1.5.6.2.1.32 | OCTET STRING (SIZE (0..32)) | RW | Extern Input | |||||||||||||||||
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of the Input Example values from LibreNMS test devices
| |||||||||||||||||||||
| Sesb7214POE | 1.3.6.1.4.1.28507.67.1.5.10 | Integer32 (0..1) | RO | 1 | |||||||||||||||||
scalar · Integer32 (0..1) · read-only · current signals POE availability
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tesb7214PwrSupplyTable | 1.3.6.1.4.1.28507.67.1.5.13 | NA | |||||||||||||||||||
table · not-accessible · current Power Supply Table - shows if Power Supply is avail | |||||||||||||||||||||
| Resb7214PwrSupplyEntry | 1.3.6.1.4.1.28507.67.1.5.13.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| Cesb7214PwrSupplyIndex | 1.3.6.1.4.1.28507.67.1.5.13.1.1 | Integer32 (1..2) | RO | 1 | |||||||||||||||||
column · Integer32 (1..2) · read-only · current Index of Power Supply entries Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214PwrSupplyStatus | 1.3.6.1.4.1.28507.67.1.5.13.1.2 | INTEGER | RO | down(0) | |||||||||||||||||
column · INTEGER · read-only · current shows status of the Power Supply 1 = fst, 2 = snd etc.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nesb7214NTPClient | 1.3.6.1.4.1.28507.67.1.5.15 | ||||||||||||||||||||
| Sesb7214NTPTimeValid | 1.3.6.1.4.1.28507.67.1.5.15.1 | INTEGER | RO | valid(1) | |||||||||||||||||
scalar · INTEGER · read-only · current Show if valid Time is received
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Sesb7214NTPUnixTime | 1.3.6.1.4.1.28507.67.1.5.15.2 | Unsigned32 | RO | 1722461498 | |||||||||||||||||
scalar · Unsigned32 · read-only · current show received NTP time as unixtime (secs since 1 January 1970)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Sesb7214NTPLastValidTimestamp | 1.3.6.1.4.1.28507.67.1.5.15.3 | Unsigned32 | RO | 2 | |||||||||||||||||
scalar · Unsigned32 · read-only · current show seconds since last valid NTP timestamp received
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nesb7214ExtSensors | 1.3.6.1.4.1.28507.67.1.6 | ||||||||||||||||||||
| Tesb7214SensorTable | 1.3.6.1.4.1.28507.67.1.6.1 | NA | |||||||||||||||||||
| Resb7214SensorEntry | 1.3.6.1.4.1.28507.67.1.6.1.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| Cesb7214SensorIndex | 1.3.6.1.4.1.28507.67.1.6.1.1.1 | Integer32 (1..4) | RO | 1 | |||||||||||||||||
column · Integer32 (1..4) · read-only · current Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214TempSensor | 1.3.6.1.4.1.28507.67.1.6.1.1.2 | Integer32 | RO | 279 | |||||||||||||||||
column · Integer32 · read-only · current actual temperature
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214HygroSensor | 1.3.6.1.4.1.28507.67.1.6.1.1.3 | Integer32 | RO | 488 | |||||||||||||||||
column · Integer32 · read-only · current actual humidity
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214InputSensor | 1.3.6.1.4.1.28507.67.1.6.1.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current logical state of input sensor
| |||||||||||||||||||||
| Cesb7214AirPressure | 1.3.6.1.4.1.28507.67.1.6.1.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current actual air pressure
| |||||||||||||||||||||
| Cesb7214DewPoint | 1.3.6.1.4.1.28507.67.1.6.1.1.6 | Integer32 | RO | 161 | |||||||||||||||||
column · Integer32 · read-only · current dew point for actual temperature and humidity
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214DewPointDiff | 1.3.6.1.4.1.28507.67.1.6.1.1.7 | Integer32 | RO | 117 | |||||||||||||||||
column · Integer32 · read-only · current difference between dew point and actual temperature (Temp - DewPoint)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cesb7214ExtSensorName | 1.3.6.1.4.1.28507.67.1.6.1.1.32 | OCTET STRING (SIZE (0..32)) | RW | i005 | |||||||||||||||||
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of a external Sensor Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nesb7214ExtInputs | 1.3.6.1.4.1.28507.67.1.6.2 | ||||||||||||||||||||
| Sesb7214ExtActiveInputs | 1.3.6.1.4.1.28507.67.1.6.2.1 | Unsigned32 (1..12) | RO | 0 | |||||||||||||||||
scalar · Unsigned32 (1..12) · read-only · current Number of suppported Input Channels. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tesb7214ExtInputTable | 1.3.6.1.4.1.28507.67.1.6.2.2 | NA | |||||||||||||||||||
| Resb7214ExtInputEntry | 1.3.6.1.4.1.28507.67.1.6.2.2.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| Cesb7214ExtInputIndex | 1.3.6.1.4.1.28507.67.1.6.2.2.1.1 | Unsigned32 | RO | ||||||||||||||||||
| Cesb7214ExtInput | 1.3.6.1.4.1.28507.67.1.6.2.2.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Input state of device
| |||||||||||||||||||||
| Cesb7214ExtInputName | 1.3.6.1.4.1.28507.67.1.6.2.2.1.32 | OCTET STRING (SIZE (0..32)) | RW | ||||||||||||||||||
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of the Input | |||||||||||||||||||||
| Cesb7214ExtInputPortNum | 1.3.6.1.4.1.28507.67.1.6.2.2.1.33 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Number of external Sensor Port when value greater zero, else device built-in Input. | |||||||||||||||||||||
| Cesb7214ExtInputBlockIndex | 1.3.6.1.4.1.28507.67.1.6.2.2.1.34 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Either index of device built-in Input, or index of Input in external sensor. | |||||||||||||||||||||
| Nesb7214Conf | 1.3.6.1.4.1.28507.67.2 | ||||||||||||||||||||
| Nesb7214Groups | 1.3.6.1.4.1.28507.67.2.1 | ||||||||||||||||||||
| Gesb7214BasicGroup | 1.3.6.1.4.1.28507.67.2.1.1 | ||||||||||||||||||||
group · current Basic objects.
| |||||||||||||||||||||
| Gesb7214NotificationGroup | 1.3.6.1.4.1.28507.67.2.1.2 | ||||||||||||||||||||
| Nesb7214Compls | 1.3.6.1.4.1.28507.67.2.2 | ||||||||||||||||||||
| Nevents | 1.3.6.1.4.1.28507.67.3 | ||||||||||||||||||||
| !esb7214SwitchEvtPort | 1.3.6.1.4.1.28507.67.3.1 | ||||||||||||||||||||
notification · current Event is triggered when a port is switched | |||||||||||||||||||||
| !esb7214InputEvt | 1.3.6.1.4.1.28507.67.3.2 | ||||||||||||||||||||
| !esb7214TempEvtSen | 1.3.6.1.4.1.28507.67.3.3 | ||||||||||||||||||||
| !esb7214HygroEvtSen | 1.3.6.1.4.1.28507.67.3.4 | ||||||||||||||||||||
| !esb7214InputEvtSen | 1.3.6.1.4.1.28507.67.3.5 | ||||||||||||||||||||
notification · current change of logical input sensor state
| |||||||||||||||||||||
| !esb7214AirPressureEvtSen | 1.3.6.1.4.1.28507.67.3.6 | ||||||||||||||||||||
| !esb7214DewPtDiffEvtSen | 1.3.6.1.4.1.28507.67.3.7 | ||||||||||||||||||||
notification · current Dew Point Difference limits exceeded | |||||||||||||||||||||
| !esb7214POEEvt | 1.3.6.1.4.1.28507.67.3.8 | ||||||||||||||||||||
| !esb7214PwrSupplyChangeEvt | 1.3.6.1.4.1.28507.67.3.9 | ||||||||||||||||||||
notification · current Event is triggered when Power Supply state changes | |||||||||||||||||||||
| !esb7214ExtInputEvt | 1.3.6.1.4.1.28507.67.3.25 | ||||||||||||||||||||
notification · current Change of external sensor input. | |||||||||||||||||||||
Traps / Notifications
- esb7214AirPressureEvtSen
1.3.6.1.4.1.28507.67.3.6 - esb7214DewPtDiffEvtSen
1.3.6.1.4.1.28507.67.3.7 - esb7214ExtInputEvt
1.3.6.1.4.1.28507.67.3.25 - esb7214HygroEvtSen
1.3.6.1.4.1.28507.67.3.4 - esb7214InputEvt
1.3.6.1.4.1.28507.67.3.2 - esb7214InputEvtSen
1.3.6.1.4.1.28507.67.3.5 - esb7214POEEvt
1.3.6.1.4.1.28507.67.3.8 - esb7214PwrSupplyChangeEvt
1.3.6.1.4.1.28507.67.3.9 - esb7214SwitchEvtPort
1.3.6.1.4.1.28507.67.3.1 - esb7214TempEvtSen
1.3.6.1.4.1.28507.67.3.3