GUDEADS-EPC8032-MIB
Gude Analog- und Digitalsysteme GmbHExpert Power Control 8032 MIB
snmptranslate -m GUDEADS-EPC8032-MIB -Tpsnmpwalk -v2c -c <community> -m GUDEADS-EPC8032-MIB <host> 1.3.6.1.4.1.28507Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Igudeads | 1.3.6.1.4.1.28507 | |||
identity Expert Power Control 8032 MIB | ||||
| NgadsEPC8032 | 1.3.6.1.4.1.28507.82 | |||
| Nepc8032Objects | 1.3.6.1.4.1.28507.82.1 | |||
| Nepc8032CommonConfig | 1.3.6.1.4.1.28507.82.1.1 | |||
| Nepc8032SNMPaccess | 1.3.6.1.4.1.28507.82.1.1.1 | |||
| Sepc8032TrapCtrl | 1.3.6.1.4.1.28507.82.1.1.1.1 | Integer32 (0..3) | RW | |
scalar · Integer32 (0..3) · read-write · current 0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3 | ||||
| Tepc8032TrapIPTable | 1.3.6.1.4.1.28507.82.1.1.1.2 | NA | ||
table · not-accessible · current list of all Trap receiver | ||||
| Repc8032TrapIPEntry | 1.3.6.1.4.1.28507.82.1.1.1.2.1 | NA | ||
row · not-accessible · current an entry containing management informations regarding the list of trap receivers
| ||||
| Cepc8032TrapIPIndex | 1.3.6.1.4.1.28507.82.1.1.1.2.1.1 | Integer32 (1..8) | RO | |
column · Integer32 (1..8) · read-only · current A unique value, greater than zero, for each receiver slot. | ||||
| Cepc8032TrapAddr | 1.3.6.1.4.1.28507.82.1.1.1.2.1.2 | OCTET STRING (SIZE (0..99)) | RW | |
column · OCTET STRING (SIZE (0..99)) · read-write · current DNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot. | ||||
| Nepc8032DeviceConfig | 1.3.6.1.4.1.28507.82.1.2 | |||
| Nepc8032IntActors | 1.3.6.1.4.1.28507.82.1.3 | |||
| Nepc8032relayports | 1.3.6.1.4.1.28507.82.1.3.1 | |||
| Sepc8032portNumber | 1.3.6.1.4.1.28507.82.1.3.1.1 | Integer32 (1..8) | RO | |
scalar · Integer32 (1..8) · read-only · current The number of Relay Ports | ||||
| Tepc8032portTable | 1.3.6.1.4.1.28507.82.1.3.1.2 | NA | ||
table · not-accessible · current list of all EPC Relay Ports | ||||
| Repc8032portEntry | 1.3.6.1.4.1.28507.82.1.3.1.2.1 | NA | ||
row · not-accessible · current An entry containing management information applicable to a particular relay port.
| ||||
| Cepc8032PortIndex | 1.3.6.1.4.1.28507.82.1.3.1.2.1.1 | Integer32 (1..8) | RO | |
column · Integer32 (1..8) · read-only · current A unique value, greater than zero, for each Relay Port. | ||||
| Cepc8032PortName | 1.3.6.1.4.1.28507.82.1.3.1.2.1.2 | OCTET STRING (SIZE (0..15)) | RW | |
column · OCTET STRING (SIZE (0..15)) · read-write · current A textual string containing name of a Relay Port. | ||||
| Cepc8032PortState | 1.3.6.1.4.1.28507.82.1.3.1.2.1.3 | INTEGER | RW | |
column · INTEGER · read-write · current current state of a Relay Port
| ||||
| Cepc8032PortSwitchCount | 1.3.6.1.4.1.28507.82.1.3.1.2.1.4 | Integer32 | RO | |
column · Integer32 · read-only · current The total number of switch actions ocurred on a Relay Port. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here. | ||||
| Cepc8032PortStartupMode | 1.3.6.1.4.1.28507.82.1.3.1.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current set Mode of startup sequence (off, on , remember last state)
| ||||
| Cepc8032PortStartupDelay | 1.3.6.1.4.1.28507.82.1.3.1.2.1.6 | Integer32 | RW | |
column · Integer32 · read-write · current Delay in sec for startup action
| ||||
| Cepc8032PortRepowerTime | 1.3.6.1.4.1.28507.82.1.3.1.2.1.7 | Integer32 (0..65535) | RW | |
column · Integer32 (0..65535) · read-write · current Delay in sec for repower port after switching off
| ||||
| Cepc8032PortResetDuration | 1.3.6.1.4.1.28507.82.1.3.1.2.1.8 | Integer32 (0..65535) | RW | |
column · Integer32 (0..65535) · read-write · current Delay in sec for turning Port on again after Reset action
| ||||
| Sepc8032Buzzer | 1.3.6.1.4.1.28507.82.1.3.10 | Integer32 (0..1) | RW | |
scalar · Integer32 (0..1) · read-write · current turn Buzzer on and off
| ||||
| Nepc8032ExtActors | 1.3.6.1.4.1.28507.82.1.4 | |||
| Nepc8032IntSensors | 1.3.6.1.4.1.28507.82.1.5 | |||
| Nepc8032PowerChan | 1.3.6.1.4.1.28507.82.1.5.1 | |||
| Sepc8032ActivePowerChan | 1.3.6.1.4.1.28507.82.1.5.1.1 | Unsigned32 (1) | RO | |
scalar · Unsigned32 (1) · read-only · current Number of suppported Power Channels. | ||||
| Tepc8032PowerTable | 1.3.6.1.4.1.28507.82.1.5.1.2 | NA | ||
table · not-accessible · current All available Channel Interfaces. | ||||
| Repc8032PowerEntry | 1.3.6.1.4.1.28507.82.1.5.1.2.1 | NA | ||
row · not-accessible · current An entry containing management information applicable to a particular Power Channel.
| ||||
| Cepc8032PowerIndex | 1.3.6.1.4.1.28507.82.1.5.1.2.1.1 | Integer32 (1) | RO | |
column · Integer32 (1) · read-only · current Index of Power Channel entries | ||||
| Cepc8032ChanStatus | 1.3.6.1.4.1.28507.82.1.5.1.2.1.2 | Integer32 (0..1) | RO | |
column · Integer32 (0..1) · read-only · current 0 = data not active, 1 = data valid | ||||
| Cepc8032AbsEnergyActive | 1.3.6.1.4.1.28507.82.1.5.1.2.1.3 | Gauge32 | RO | |
column · Gauge32 · read-only · current Absolute Active Energy counter.
| ||||
| Cepc8032PowerActive | 1.3.6.1.4.1.28507.82.1.5.1.2.1.4 | Integer32 | RO | |
column · Integer32 · read-only · current Active Power
| ||||
| Cepc8032Current | 1.3.6.1.4.1.28507.82.1.5.1.2.1.5 | Gauge32 | RO | |
column · Gauge32 · read-only · current Actual Curent on Power Channel.
| ||||
| Cepc8032Voltage | 1.3.6.1.4.1.28507.82.1.5.1.2.1.6 | Gauge32 | RO | |
column · Gauge32 · read-only · current Actual Voltage on Power Channel
| ||||
| Cepc8032Frequency | 1.3.6.1.4.1.28507.82.1.5.1.2.1.7 | Gauge32 | RO | |
column · Gauge32 · read-only · current Frequency of Power Channel
| ||||
| Cepc8032PowerFactor | 1.3.6.1.4.1.28507.82.1.5.1.2.1.8 | Integer32 | RO | |
column · Integer32 · read-only · current Power Factor of Channel between -1.0 and 1.00
| ||||
| Cepc8032Pangle | 1.3.6.1.4.1.28507.82.1.5.1.2.1.9 | Integer32 | RO | |
column · Integer32 · read-only · current Phase Angle between Voltage and L Line Current between -180.0 and 180.0
| ||||
| Cepc8032PowerApparent | 1.3.6.1.4.1.28507.82.1.5.1.2.1.10 | Integer32 | RO | |
column · Integer32 · read-only · current L Line Mean Apparent Power
| ||||
| Cepc8032PowerReactive | 1.3.6.1.4.1.28507.82.1.5.1.2.1.11 | Integer32 | RO | |
column · Integer32 · read-only · current L Line Mean Reactive Power
| ||||
| Cepc8032AbsEnergyReactive | 1.3.6.1.4.1.28507.82.1.5.1.2.1.12 | Gauge32 | RO | |
column · Gauge32 · read-only · current Absolute Reactive Energy counter.
| ||||
| Cepc8032AbsEnergyActiveResettable | 1.3.6.1.4.1.28507.82.1.5.1.2.1.13 | Gauge32 | RW | |
column · Gauge32 · read-write · current Resettable Absolute Active Energy counter. Writing '0' resets all resettable counter.
| ||||
| Cepc8032AbsEnergyReactiveResettable | 1.3.6.1.4.1.28507.82.1.5.1.2.1.14 | Gauge32 | RO | |
column · Gauge32 · read-only · current Resettable Absolute Reactive Energy counter.
| ||||
| Cepc8032ResetTime | 1.3.6.1.4.1.28507.82.1.5.1.2.1.15 | Gauge32 | RO | |
column · Gauge32 · read-only · current Time in seconds since last Energy Counter reset.
| ||||
| Cepc8032ForwEnergyActive | 1.3.6.1.4.1.28507.82.1.5.1.2.1.16 | Gauge32 | RO | |
column · Gauge32 · read-only · current Forward Active Energy counter.
| ||||
| Cepc8032ForwEnergyReactive | 1.3.6.1.4.1.28507.82.1.5.1.2.1.17 | Gauge32 | RO | |
column · Gauge32 · read-only · current Forward Reactive Energy counter.
| ||||
| Cepc8032ForwEnergyActiveResettable | 1.3.6.1.4.1.28507.82.1.5.1.2.1.18 | Gauge32 | RO | |
column · Gauge32 · read-only · current Resettable Forward Active Energy counter.
| ||||
| Cepc8032ForwEnergyReactiveResettable | 1.3.6.1.4.1.28507.82.1.5.1.2.1.19 | Gauge32 | RO | |
column · Gauge32 · read-only · current Resettable Forward Reactive Energy counter.
| ||||
| Cepc8032RevEnergyActive | 1.3.6.1.4.1.28507.82.1.5.1.2.1.20 | Gauge32 | RO | |
column · Gauge32 · read-only · current Reverse Active Energy counter.
| ||||
| Cepc8032RevEnergyReactive | 1.3.6.1.4.1.28507.82.1.5.1.2.1.21 | Gauge32 | RO | |
column · Gauge32 · read-only · current Reverse Reactive Energy counter.
| ||||
| Cepc8032RevEnergyActiveResettable | 1.3.6.1.4.1.28507.82.1.5.1.2.1.22 | Gauge32 | RO | |
column · Gauge32 · read-only · current Resettable Reverse Active Energy counter.
| ||||
| Cepc8032RevEnergyReactiveResettable | 1.3.6.1.4.1.28507.82.1.5.1.2.1.23 | Gauge32 | RO | |
column · Gauge32 · read-only · current Resettable Reverse Reactive Energy counter.
| ||||
| Cepc8032ResidualCurrent | 1.3.6.1.4.1.28507.82.1.5.1.2.1.24 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Actual Residual Current on Power Channel. According Type A IEC 60755. Only visible on models that support this feature.
| ||||
| Cepc8032ResidualCurrentRMS | 1.3.6.1.4.1.28507.82.1.5.1.2.1.25 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Actual Residual Current RMS on Power Channel. According Type B IEC 60755. Only visible on models that support this feature.
| ||||
| Cepc8032ResidualCurrentDC | 1.3.6.1.4.1.28507.82.1.5.1.2.1.26 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Actual Residual Current DC on Power Channel. According Type B IEC 60755. Only visible on models that support this feature.
| ||||
| Cepc8032LineSensorName | 1.3.6.1.4.1.28507.82.1.5.1.2.1.100 | OCTET STRING (SIZE (0..32)) | RW | |
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of a Line Sensor | ||||
| Tepc8032OVPTable | 1.3.6.1.4.1.28507.82.1.5.2 | NA | ||
table · not-accessible · current Overvoltage Protection Table This table may not be present on devices without OVP feature | ||||
| Repc8032OVPEntry | 1.3.6.1.4.1.28507.82.1.5.2.1 | NA | ||
row · not-accessible · current
| ||||
| Cepc8032OVPIndex | 1.3.6.1.4.1.28507.82.1.5.2.1.1 | Integer32 (1) | RO | |
| Cepc8032OVPStatus | 1.3.6.1.4.1.28507.82.1.5.2.1.2 | INTEGER | RO | |
column · INTEGER · read-only · current shows the status of the built-in Overvoltage Protection
| ||||
| Nepc8032CPUSensors | 1.3.6.1.4.1.28507.82.1.5.14 | |||
| Sepc8032CPUSensorVsystem | 1.3.6.1.4.1.28507.82.1.5.14.1 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current System Voltage on CPU Board
| ||||
| Sepc8032CPUSensorVaux | 1.3.6.1.4.1.28507.82.1.5.14.2 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current Auxiliary Voltage on CPU Board
| ||||
| Sepc8032CPUSensorVmain | 1.3.6.1.4.1.28507.82.1.5.14.3 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current Main Voltage on CPU Board
| ||||
| Sepc8032CPUSensorTcpu | 1.3.6.1.4.1.28507.82.1.5.14.4 | Integer32 | RO | |
scalar · Integer32 · read-only · current Temperature on CPU Board
| ||||
| Nepc8032NTPClient | 1.3.6.1.4.1.28507.82.1.5.15 | |||
| Sepc8032NTPTimeValid | 1.3.6.1.4.1.28507.82.1.5.15.1 | INTEGER | RO | |
scalar · INTEGER · read-only · current Show if valid Time is received
| ||||
| Sepc8032NTPUnixTime | 1.3.6.1.4.1.28507.82.1.5.15.2 | Unsigned32 | RO | |
scalar · Unsigned32 · read-only · current show received NTP time as unixtime (secs since 1 January 1970)
| ||||
| Sepc8032NTPLastValidTimestamp | 1.3.6.1.4.1.28507.82.1.5.15.3 | Unsigned32 | RO | |
scalar · Unsigned32 · read-only · current show seconds since last valid NTP timestamp received
| ||||
| Nepc8032ExtSensors | 1.3.6.1.4.1.28507.82.1.6 | |||
| Tepc8032SensorTable | 1.3.6.1.4.1.28507.82.1.6.1 | NA | ||
| Repc8032SensorEntry | 1.3.6.1.4.1.28507.82.1.6.1.1 | NA | ||
row · not-accessible · current
| ||||
| Cepc8032SensorIndex | 1.3.6.1.4.1.28507.82.1.6.1.1.1 | Integer32 (1..2) | RO | |
| Cepc8032TempSensor | 1.3.6.1.4.1.28507.82.1.6.1.1.2 | Integer32 | RO | |
column · Integer32 · read-only · current actual temperature
| ||||
| Cepc8032HygroSensor | 1.3.6.1.4.1.28507.82.1.6.1.1.3 | Integer32 | RO | |
column · Integer32 · read-only · current actual humidity
| ||||
| Cepc8032AirPressure | 1.3.6.1.4.1.28507.82.1.6.1.1.5 | Integer32 | RO | |
column · Integer32 · read-only · current actual air pressure
| ||||
| Cepc8032DewPoint | 1.3.6.1.4.1.28507.82.1.6.1.1.6 | Integer32 | RO | |
column · Integer32 · read-only · current dew point for actual temperature and humidity
| ||||
| Cepc8032DewPointDiff | 1.3.6.1.4.1.28507.82.1.6.1.1.7 | Integer32 | RO | |
column · Integer32 · read-only · current difference between dew point and actual temperature (Temp - DewPoint)
| ||||
| Cepc8032ExtSensorName | 1.3.6.1.4.1.28507.82.1.6.1.1.32 | OCTET STRING (SIZE (0..32)) | RW | |
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of a external Sensor | ||||
| Nepc8032Conf | 1.3.6.1.4.1.28507.82.2 | |||
| Nepc8032Groups | 1.3.6.1.4.1.28507.82.2.1 | |||
| Gepc8032BasicGroup | 1.3.6.1.4.1.28507.82.2.1.1 | |||
group · current Basic objects.
| ||||
| Gepc8032NotificationGroup | 1.3.6.1.4.1.28507.82.2.1.2 | |||
| Nepc8032Compls | 1.3.6.1.4.1.28507.82.2.2 | |||
| Nevents | 1.3.6.1.4.1.28507.82.3 | |||
| !epc8032SwitchEvtPort | 1.3.6.1.4.1.28507.82.3.1 | |||
notification · current Event is triggered when a port is switched | ||||
| !epc8032TempEvtSen | 1.3.6.1.4.1.28507.82.3.2 | |||
| !epc8032HygroEvtSen | 1.3.6.1.4.1.28507.82.3.3 | |||
| !epc8032AirPressureEvtSen | 1.3.6.1.4.1.28507.82.3.4 | |||
| !epc8032DewPtDiffEvtSen | 1.3.6.1.4.1.28507.82.3.5 | |||
notification · current Dew Point Difference limits exceeded | ||||
| !epc8032OVPEvt | 1.3.6.1.4.1.28507.82.3.6 | |||
notification · current Event is triggered when the OVP status changes
| ||||
| !epc8032LineResidualCurrentEvt | 1.3.6.1.4.1.28507.82.3.7 | |||
notification · current Event is triggered when a measured residual current is crossing the entered limits | ||||
| !epc8032LineAmperageEvt | 1.3.6.1.4.1.28507.82.3.8 | |||
notification · current Event is triggered when a measured current is crossing the entered limits | ||||
| !epc8032LineResidualCurrentRMSEvt | 1.3.6.1.4.1.28507.82.3.9 | |||
notification · current Event is triggered when a measured residual current Type B RMS is crossing the entered limits | ||||
| !epc8032LineResidualCurrentDCEvt | 1.3.6.1.4.1.28507.82.3.10 | |||
notification · current Event is triggered when a measured residual current Type B DC is crossing the entered limits | ||||
Traps / Notifications
- epc8032AirPressureEvtSen
1.3.6.1.4.1.28507.82.3.4 - epc8032DewPtDiffEvtSen
1.3.6.1.4.1.28507.82.3.5 - epc8032HygroEvtSen
1.3.6.1.4.1.28507.82.3.3 - epc8032LineAmperageEvt
1.3.6.1.4.1.28507.82.3.8 - epc8032LineResidualCurrentDCEvt
1.3.6.1.4.1.28507.82.3.10 - epc8032LineResidualCurrentEvt
1.3.6.1.4.1.28507.82.3.7 - epc8032LineResidualCurrentRMSEvt
1.3.6.1.4.1.28507.82.3.9 - epc8032OVPEvt
1.3.6.1.4.1.28507.82.3.6 - epc8032SwitchEvtPort
1.3.6.1.4.1.28507.82.3.1 - epc8032TempEvtSen
1.3.6.1.4.1.28507.82.3.2