GUDEADS-EPC8031-MIB
Gude Analog- und Digitalsysteme GmbHExpert Power Control 8031 MIB
snmptranslate -m GUDEADS-EPC8031-MIB -Tpsnmpwalk -v2c -c <community> -m GUDEADS-EPC8031-MIB <host> 1.3.6.1.4.1.28507Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Igudeads | 1.3.6.1.4.1.28507 | ||||||||||||||||
identity Expert Power Control 8031 MIB | |||||||||||||||||
| NgadsEPC8031 | 1.3.6.1.4.1.28507.81 | ||||||||||||||||
| Nepc8031Objects | 1.3.6.1.4.1.28507.81.1 | ||||||||||||||||
| Nepc8031CommonConfig | 1.3.6.1.4.1.28507.81.1.1 | ||||||||||||||||
| Nepc8031SNMPaccess | 1.3.6.1.4.1.28507.81.1.1.1 | ||||||||||||||||
| Sepc8031TrapCtrl | 1.3.6.1.4.1.28507.81.1.1.1.1 | Integer32 (0..3) | RW | ||||||||||||||
scalar · Integer32 (0..3) · read-write · current 0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3 | |||||||||||||||||
| Tepc8031TrapIPTable | 1.3.6.1.4.1.28507.81.1.1.1.2 | NA | |||||||||||||||
table · not-accessible · current list of all Trap receiver | |||||||||||||||||
| Repc8031TrapIPEntry | 1.3.6.1.4.1.28507.81.1.1.1.2.1 | NA | |||||||||||||||
row · not-accessible · current an entry containing management informations regarding the list of trap receivers
| |||||||||||||||||
| Cepc8031TrapIPIndex | 1.3.6.1.4.1.28507.81.1.1.1.2.1.1 | Integer32 (1..8) | RO | ||||||||||||||
column · Integer32 (1..8) · read-only · current A unique value, greater than zero, for each receiver slot. | |||||||||||||||||
| Cepc8031TrapAddr | 1.3.6.1.4.1.28507.81.1.1.1.2.1.2 | OCTET STRING (SIZE (0..99)) | RW | ||||||||||||||
column · OCTET STRING (SIZE (0..99)) · read-write · current DNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot. | |||||||||||||||||
| Nepc8031DeviceInfo | 1.3.6.1.4.1.28507.81.1.1.2 | ||||||||||||||||
| Sepc8031ProdName | 1.3.6.1.4.1.28507.81.1.1.2.1 | OCTET STRING | RO | Expert Power Control 8031-3 | |||||||||||||
scalar · OCTET STRING · read-only · current The Product Name of the device. Example values from LibreNMS test devices
| |||||||||||||||||
| Sepc8031FWVersion | 1.3.6.1.4.1.28507.81.1.1.2.2 | OCTET STRING | RO | 1.6.3 | |||||||||||||
scalar · OCTET STRING · read-only · current Firmware Version of the device. Example values from LibreNMS test devices
| |||||||||||||||||
| Sepc8031HostName | 1.3.6.1.4.1.28507.81.1.1.2.3 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current The configured Host Name. | |||||||||||||||||
| Sepc8031PhysAddress | 1.3.6.1.4.1.28507.81.1.1.2.4 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current The MAC address of the device. | |||||||||||||||||
| Sepc8031SerialNumber | 1.3.6.1.4.1.28507.81.1.1.2.5 | Unsigned32 | RO | ||||||||||||||
scalar · Unsigned32 · read-only · current The Serial Number of the device. Not available for all devices. Production start 2026. | |||||||||||||||||
| Nepc8031DeviceConfig | 1.3.6.1.4.1.28507.81.1.2 | ||||||||||||||||
| Nepc8031IntActors | 1.3.6.1.4.1.28507.81.1.3 | ||||||||||||||||
| Nepc8031relayports | 1.3.6.1.4.1.28507.81.1.3.1 | ||||||||||||||||
| Sepc8031portNumber | 1.3.6.1.4.1.28507.81.1.3.1.1 | Integer32 (1..8) | RO | ||||||||||||||
scalar · Integer32 (1..8) · read-only · current The number of Relay Ports | |||||||||||||||||
| Tepc8031portTable | 1.3.6.1.4.1.28507.81.1.3.1.2 | NA | |||||||||||||||
table · not-accessible · current list of all EPC Relay Ports | |||||||||||||||||
| Repc8031portEntry | 1.3.6.1.4.1.28507.81.1.3.1.2.1 | NA | |||||||||||||||
row · not-accessible · current An entry containing management information applicable to a particular relay port.
| |||||||||||||||||
| Cepc8031PortIndex | 1.3.6.1.4.1.28507.81.1.3.1.2.1.1 | Integer32 (1..8) | RO | ||||||||||||||
column · Integer32 (1..8) · read-only · current A unique value, greater than zero, for each Relay Port. | |||||||||||||||||
| Cepc8031PortName | 1.3.6.1.4.1.28507.81.1.3.1.2.1.2 | OCTET STRING (SIZE (0..15)) | RW | ||||||||||||||
column · OCTET STRING (SIZE (0..15)) · read-write · current A textual string containing name of a Relay Port. | |||||||||||||||||
| Cepc8031PortState | 1.3.6.1.4.1.28507.81.1.3.1.2.1.3 | INTEGER | RW | off(0) | |||||||||||||
column · INTEGER · read-write · current current state of a Relay Port
Example values from LibreNMS test devices
| |||||||||||||||||
| Cepc8031PortSwitchCount | 1.3.6.1.4.1.28507.81.1.3.1.2.1.4 | Integer32 | RO | 0 | |||||||||||||
column · Integer32 · read-only · current The total number of switch actions ocurred on a Relay Port. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here. Example values from LibreNMS test devices
| |||||||||||||||||
| Cepc8031PortStartupMode | 1.3.6.1.4.1.28507.81.1.3.1.2.1.5 | INTEGER | RW | ||||||||||||||
column · INTEGER · read-write · current set Mode of startup sequence (off, on , remember last state)
| |||||||||||||||||
| Cepc8031PortStartupDelay | 1.3.6.1.4.1.28507.81.1.3.1.2.1.6 | Integer32 | RW | ||||||||||||||
column · Integer32 · read-write · current Delay in sec for startup action
| |||||||||||||||||
| Cepc8031PortRepowerTime | 1.3.6.1.4.1.28507.81.1.3.1.2.1.7 | Integer32 (0..65535) | RW | ||||||||||||||
column · Integer32 (0..65535) · read-write · current Delay in sec for repower port after switching off
| |||||||||||||||||
| Cepc8031PortResetDuration | 1.3.6.1.4.1.28507.81.1.3.1.2.1.8 | Integer32 (0..65535) | RW | ||||||||||||||
column · Integer32 (0..65535) · read-write · current Delay in sec for turning Port on again after Reset action
| |||||||||||||||||
| Sepc8031Buzzer | 1.3.6.1.4.1.28507.81.1.3.10 | Integer32 (0..1) | RW | ||||||||||||||
scalar · Integer32 (0..1) · read-write · current turn Buzzer on and off
| |||||||||||||||||
| Nepc8031ExtActors | 1.3.6.1.4.1.28507.81.1.4 | ||||||||||||||||
| Nepc8031IntSensors | 1.3.6.1.4.1.28507.81.1.5 | ||||||||||||||||
| Nepc8031PowerChan | 1.3.6.1.4.1.28507.81.1.5.1 | ||||||||||||||||
| Sepc8031ActivePowerChan | 1.3.6.1.4.1.28507.81.1.5.1.1 | Unsigned32 (1) | RO | ||||||||||||||
scalar · Unsigned32 (1) · read-only · current Number of suppported Power Channels. | |||||||||||||||||
| Tepc8031PowerTable | 1.3.6.1.4.1.28507.81.1.5.1.2 | NA | |||||||||||||||
table · not-accessible · current All available Channel Interfaces. | |||||||||||||||||
| Repc8031PowerEntry | 1.3.6.1.4.1.28507.81.1.5.1.2.1 | NA | |||||||||||||||
row · not-accessible · current An entry containing management information applicable to a particular Power Channel.
| |||||||||||||||||
| Cepc8031PowerIndex | 1.3.6.1.4.1.28507.81.1.5.1.2.1.1 | Integer32 (1) | RO | ||||||||||||||
column · Integer32 (1) · read-only · current Index of Power Channel entries | |||||||||||||||||
| Cepc8031ChanStatus | 1.3.6.1.4.1.28507.81.1.5.1.2.1.2 | Integer32 (0..1) | RO | 1 | |||||||||||||
column · Integer32 (0..1) · read-only · current 0 = data not active, 1 = data valid Example values from LibreNMS test devices
| |||||||||||||||||
| Cepc8031AbsEnergyActive | 1.3.6.1.4.1.28507.81.1.5.1.2.1.3 | Gauge32 | RO | 1109596 | |||||||||||||
column · Gauge32 · read-only · current Absolute Active Energy counter.
Example values from LibreNMS test devices
| |||||||||||||||||
| Cepc8031PowerActive | 1.3.6.1.4.1.28507.81.1.5.1.2.1.4 | Integer32 | RO | 18 | |||||||||||||
column · Integer32 · read-only · current Active Power
Example values from LibreNMS test devices
| |||||||||||||||||
| Cepc8031Current | 1.3.6.1.4.1.28507.81.1.5.1.2.1.5 | Gauge32 | RO | 186 | |||||||||||||
column · Gauge32 · read-only · current Actual Curent on Power Channel.
Example values from LibreNMS test devices
| |||||||||||||||||
| Cepc8031Voltage | 1.3.6.1.4.1.28507.81.1.5.1.2.1.6 | Gauge32 | RO | 230 | |||||||||||||
column · Gauge32 · read-only · current Actual Voltage on Power Channel
Example values from LibreNMS test devices
| |||||||||||||||||
| Cepc8031Frequency | 1.3.6.1.4.1.28507.81.1.5.1.2.1.7 | Gauge32 | RO | 4999 | |||||||||||||
column · Gauge32 · read-only · current Frequency of Power Channel
Example values from LibreNMS test devices
| |||||||||||||||||
| Cepc8031PowerFactor | 1.3.6.1.4.1.28507.81.1.5.1.2.1.8 | Integer32 | RO | 424 | |||||||||||||
column · Integer32 · read-only · current Power Factor of Channel between -1.0 and 1.00
Example values from LibreNMS test devices
| |||||||||||||||||
| Cepc8031Pangle | 1.3.6.1.4.1.28507.81.1.5.1.2.1.9 | Integer32 | RO | ||||||||||||||
column · Integer32 · read-only · current Phase Angle between Voltage and L Line Current between -180.0 and 180.0
| |||||||||||||||||
| Cepc8031PowerApparent | 1.3.6.1.4.1.28507.81.1.5.1.2.1.10 | Integer32 | RO | 42 | |||||||||||||
column · Integer32 · read-only · current L Line Mean Apparent Power
Example values from LibreNMS test devices
| |||||||||||||||||
| Cepc8031PowerReactive | 1.3.6.1.4.1.28507.81.1.5.1.2.1.11 | Integer32 | RO | ||||||||||||||
column · Integer32 · read-only · current L Line Mean Reactive Power
| |||||||||||||||||
| Cepc8031AbsEnergyReactive | 1.3.6.1.4.1.28507.81.1.5.1.2.1.12 | Gauge32 | RO | ||||||||||||||
column · Gauge32 · read-only · current Absolute Reactive Energy counter.
| |||||||||||||||||
| Cepc8031AbsEnergyActiveResettable | 1.3.6.1.4.1.28507.81.1.5.1.2.1.13 | Gauge32 | RW | 1109592 | |||||||||||||
column · Gauge32 · read-write · current Resettable Absolute Active Energy counter. Writing '0' resets all resettable counter.
Example values from LibreNMS test devices
| |||||||||||||||||
| Cepc8031AbsEnergyReactiveResettable | 1.3.6.1.4.1.28507.81.1.5.1.2.1.14 | Gauge32 | RO | ||||||||||||||
column · Gauge32 · read-only · current Resettable Absolute Reactive Energy counter.
| |||||||||||||||||
| Cepc8031ResetTime | 1.3.6.1.4.1.28507.81.1.5.1.2.1.15 | Gauge32 | RO | ||||||||||||||
column · Gauge32 · read-only · current Time in seconds since last Energy Counter reset.
| |||||||||||||||||
| Cepc8031ForwEnergyActive | 1.3.6.1.4.1.28507.81.1.5.1.2.1.16 | Gauge32 | RO | ||||||||||||||
column · Gauge32 · read-only · current Forward Active Energy counter.
| |||||||||||||||||
| Cepc8031ForwEnergyReactive | 1.3.6.1.4.1.28507.81.1.5.1.2.1.17 | Gauge32 | RO | ||||||||||||||
column · Gauge32 · read-only · current Forward Reactive Energy counter.
| |||||||||||||||||
| Cepc8031ForwEnergyActiveResettable | 1.3.6.1.4.1.28507.81.1.5.1.2.1.18 | Gauge32 | RO | ||||||||||||||
column · Gauge32 · read-only · current Resettable Forward Active Energy counter.
| |||||||||||||||||
| Cepc8031ForwEnergyReactiveResettable | 1.3.6.1.4.1.28507.81.1.5.1.2.1.19 | Gauge32 | RO | ||||||||||||||
column · Gauge32 · read-only · current Resettable Forward Reactive Energy counter.
| |||||||||||||||||
| Cepc8031RevEnergyActive | 1.3.6.1.4.1.28507.81.1.5.1.2.1.20 | Gauge32 | RO | ||||||||||||||
column · Gauge32 · read-only · current Reverse Active Energy counter.
| |||||||||||||||||
| Cepc8031RevEnergyReactive | 1.3.6.1.4.1.28507.81.1.5.1.2.1.21 | Gauge32 | RO | ||||||||||||||
column · Gauge32 · read-only · current Reverse Reactive Energy counter.
| |||||||||||||||||
| Cepc8031RevEnergyActiveResettable | 1.3.6.1.4.1.28507.81.1.5.1.2.1.22 | Gauge32 | RO | ||||||||||||||
column · Gauge32 · read-only · current Resettable Reverse Active Energy counter.
| |||||||||||||||||
| Cepc8031RevEnergyReactiveResettable | 1.3.6.1.4.1.28507.81.1.5.1.2.1.23 | Gauge32 | RO | ||||||||||||||
column · Gauge32 · read-only · current Resettable Reverse Reactive Energy counter.
| |||||||||||||||||
| Cepc8031ResidualCurrent | 1.3.6.1.4.1.28507.81.1.5.1.2.1.24 | Unsigned32 | RO | 5 | |||||||||||||
column · Unsigned32 · read-only · current Actual Residual Current on Power Channel. According Type A IEC 60755. Only visible on models that support this feature.
Example values from LibreNMS test devices
| |||||||||||||||||
| Cepc8031LineSensorName | 1.3.6.1.4.1.28507.81.1.5.1.2.1.100 | OCTET STRING (SIZE (0..32)) | RW | ||||||||||||||
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of a Line Sensor | |||||||||||||||||
| Tepc8031OVPTable | 1.3.6.1.4.1.28507.81.1.5.2 | NA | |||||||||||||||
table · not-accessible · current Overvoltage Protection Table This table may not be present on devices without OVP feature | |||||||||||||||||
| Repc8031OVPEntry | 1.3.6.1.4.1.28507.81.1.5.2.1 | NA | |||||||||||||||
row · not-accessible · current
| |||||||||||||||||
| Cepc8031OVPIndex | 1.3.6.1.4.1.28507.81.1.5.2.1.1 | Integer32 (1) | RO | ||||||||||||||
| Cepc8031OVPStatus | 1.3.6.1.4.1.28507.81.1.5.2.1.2 | INTEGER | RO | ok(1) | |||||||||||||
column · INTEGER · read-only · current shows the status of the built-in Overvoltage Protection
Example values from LibreNMS test devices
| |||||||||||||||||
| Nepc8031CPUSensors | 1.3.6.1.4.1.28507.81.1.5.14 | ||||||||||||||||
| Sepc8031CPUSensorVsystem | 1.3.6.1.4.1.28507.81.1.5.14.1 | Gauge32 | RO | 329 | |||||||||||||
scalar · Gauge32 · read-only · current System Voltage on CPU Board
Example values from LibreNMS test devices
| |||||||||||||||||
| Sepc8031CPUSensorVaux | 1.3.6.1.4.1.28507.81.1.5.14.2 | Gauge32 | RO | 403 | |||||||||||||
scalar · Gauge32 · read-only · current Auxiliary Voltage on CPU Board
Example values from LibreNMS test devices
| |||||||||||||||||
| Sepc8031CPUSensorVmain | 1.3.6.1.4.1.28507.81.1.5.14.3 | Gauge32 | RO | 1156 | |||||||||||||
scalar · Gauge32 · read-only · current Main Voltage on CPU Board
Example values from LibreNMS test devices
| |||||||||||||||||
| Sepc8031CPUSensorTcpu | 1.3.6.1.4.1.28507.81.1.5.14.4 | Integer32 | RO | 375 | |||||||||||||
scalar · Integer32 · read-only · current Temperature on CPU Board Example values from LibreNMS test devices
| |||||||||||||||||
| Nepc8031NTPClient | 1.3.6.1.4.1.28507.81.1.5.15 | ||||||||||||||||
| Sepc8031NTPTimeValid | 1.3.6.1.4.1.28507.81.1.5.15.1 | INTEGER | RO | valid(1) | |||||||||||||
scalar · INTEGER · read-only · current Show if valid Time is received
Example values from LibreNMS test devices
| |||||||||||||||||
| Sepc8031NTPUnixTime | 1.3.6.1.4.1.28507.81.1.5.15.2 | Unsigned32 | RO | ||||||||||||||
scalar · Unsigned32 · read-only · current show received NTP time as unixtime (secs since 1 January 1970)
| |||||||||||||||||
| Sepc8031NTPLastValidTimestamp | 1.3.6.1.4.1.28507.81.1.5.15.3 | Unsigned32 | RO | ||||||||||||||
scalar · Unsigned32 · read-only · current show seconds since last valid NTP timestamp received
| |||||||||||||||||
| Tepc8031RCMBInfoTable | 1.3.6.1.4.1.28507.81.1.5.16 | NA | |||||||||||||||
table · not-accessible · current RCMB Module Information Only visible on models that support this feature. | |||||||||||||||||
| Repc8031RCMBInfoEntry | 1.3.6.1.4.1.28507.81.1.5.16.1 | NA | |||||||||||||||
row · not-accessible · current
| |||||||||||||||||
| Cepc8031RCMBInfoIndex | 1.3.6.1.4.1.28507.81.1.5.16.1.1 | Integer32 (1) | RO | ||||||||||||||
column · Integer32 (1) · read-only · current Index of RCMB Info entries | |||||||||||||||||
| Cepc8031RCMBCurrentRMS | 1.3.6.1.4.1.28507.81.1.5.16.1.2 | Unsigned32 | RO | ||||||||||||||
column · Unsigned32 · read-only · current Actual Residual Current RMS on Power Channel. According Type B IEC 60755. Only visible on models that support this feature.
| |||||||||||||||||
| Cepc8031RCMBCurrentDC | 1.3.6.1.4.1.28507.81.1.5.16.1.3 | Unsigned32 | RO | ||||||||||||||
column · Unsigned32 · read-only · current Actual Residual Current DC on Power Channel. According Type B IEC 60755. Only visible on models that support this feature.
| |||||||||||||||||
| Cepc8031RCMBOutputRMS | 1.3.6.1.4.1.28507.81.1.5.16.1.4 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current shows the output S1 of the RCMB module
| |||||||||||||||||
| Cepc8031RCMBOutputDC | 1.3.6.1.4.1.28507.81.1.5.16.1.5 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current shows the output S2 of the RCMB module
| |||||||||||||||||
| Cepc8031RCMBModuleStatus | 1.3.6.1.4.1.28507.81.1.5.16.1.6 | Unsigned32 | RO | ||||||||||||||
column · Unsigned32 · read-only · current RCMB Module Status Word | |||||||||||||||||
| Nepc8031ExtSensors | 1.3.6.1.4.1.28507.81.1.6 | ||||||||||||||||
| Tepc8031SensorTable | 1.3.6.1.4.1.28507.81.1.6.1 | NA | |||||||||||||||
| Repc8031SensorEntry | 1.3.6.1.4.1.28507.81.1.6.1.1 | NA | |||||||||||||||
row · not-accessible · current
| |||||||||||||||||
| Cepc8031SensorIndex | 1.3.6.1.4.1.28507.81.1.6.1.1.1 | Integer32 (1..2) | RO | ||||||||||||||
| Cepc8031TempSensor | 1.3.6.1.4.1.28507.81.1.6.1.1.2 | Integer32 | RO | ||||||||||||||
column · Integer32 · read-only · current actual temperature | |||||||||||||||||
| Cepc8031HygroSensor | 1.3.6.1.4.1.28507.81.1.6.1.1.3 | Integer32 | RO | ||||||||||||||
column · Integer32 · read-only · current actual humidity
| |||||||||||||||||
| Cepc8031AirPressure | 1.3.6.1.4.1.28507.81.1.6.1.1.5 | Integer32 | RO | ||||||||||||||
column · Integer32 · read-only · current actual air pressure | |||||||||||||||||
| Cepc8031DewPoint | 1.3.6.1.4.1.28507.81.1.6.1.1.6 | Integer32 | RO | ||||||||||||||
column · Integer32 · read-only · current dew point for actual temperature and humidity | |||||||||||||||||
| Cepc8031DewPointDiff | 1.3.6.1.4.1.28507.81.1.6.1.1.7 | Integer32 | RO | ||||||||||||||
column · Integer32 · read-only · current difference between dew point and actual temperature (Temp - DewPoint) | |||||||||||||||||
| Cepc8031ExtSensorName | 1.3.6.1.4.1.28507.81.1.6.1.1.32 | OCTET STRING (SIZE (0..32)) | RW | ||||||||||||||
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of a external Sensor | |||||||||||||||||
| Nepc8031ExtInputs | 1.3.6.1.4.1.28507.81.1.6.2 | ||||||||||||||||
| Sepc8031ExtActiveInputs | 1.3.6.1.4.1.28507.81.1.6.2.1 | Unsigned32 | RO | ||||||||||||||
scalar · Unsigned32 · read-only · current Number of suppported Input Channels. | |||||||||||||||||
| Tepc8031ExtInputTable | 1.3.6.1.4.1.28507.81.1.6.2.2 | NA | |||||||||||||||
| Repc8031ExtInputEntry | 1.3.6.1.4.1.28507.81.1.6.2.2.1 | NA | |||||||||||||||
row · not-accessible · current
| |||||||||||||||||
| Cepc8031ExtInputIndex | 1.3.6.1.4.1.28507.81.1.6.2.2.1.1 | Unsigned32 | RO | ||||||||||||||
| Cepc8031ExtInput | 1.3.6.1.4.1.28507.81.1.6.2.2.1.2 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current Input state of device
| |||||||||||||||||
| Cepc8031ExtInputToggleCount | 1.3.6.1.4.1.28507.81.1.6.2.2.1.3 | Unsigned32 | RO | ||||||||||||||
column · Unsigned32 · read-only · current Number of times the Input has changed its state. | |||||||||||||||||
| Cepc8031ExtInputName | 1.3.6.1.4.1.28507.81.1.6.2.2.1.32 | OCTET STRING (SIZE (0..32)) | RW | ||||||||||||||
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of the Input | |||||||||||||||||
| Cepc8031ExtInputPortNum | 1.3.6.1.4.1.28507.81.1.6.2.2.1.33 | Integer32 | RO | ||||||||||||||
column · Integer32 · read-only · current Number of external Sensor Port when value greater zero, else device built-in Input. | |||||||||||||||||
| Cepc8031ExtInputBlockIndex | 1.3.6.1.4.1.28507.81.1.6.2.2.1.34 | Integer32 | RO | ||||||||||||||
column · Integer32 · read-only · current Either index of device built-in Input, or index of Input in external sensor. | |||||||||||||||||
| Nepc8031Conf | 1.3.6.1.4.1.28507.81.2 | ||||||||||||||||
| Nepc8031Groups | 1.3.6.1.4.1.28507.81.2.1 | ||||||||||||||||
| Gepc8031BasicGroup | 1.3.6.1.4.1.28507.81.2.1.1 | ||||||||||||||||
group · current Basic objects.
| |||||||||||||||||
| Gepc8031NotificationGroup | 1.3.6.1.4.1.28507.81.2.1.2 | ||||||||||||||||
group · current
| |||||||||||||||||
| Nepc8031Compls | 1.3.6.1.4.1.28507.81.2.2 | ||||||||||||||||
| Nevents | 1.3.6.1.4.1.28507.81.3 | ||||||||||||||||
| !epc8031SwitchEvtPort | 1.3.6.1.4.1.28507.81.3.1 | ||||||||||||||||
notification · current Event is triggered when a port is switched | |||||||||||||||||
| !epc8031TempEvtSen | 1.3.6.1.4.1.28507.81.3.2 | ||||||||||||||||
| !epc8031HygroEvtSen | 1.3.6.1.4.1.28507.81.3.3 | ||||||||||||||||
| !epc8031AirPressureEvtSen | 1.3.6.1.4.1.28507.81.3.4 | ||||||||||||||||
| !epc8031DewPtDiffEvtSen | 1.3.6.1.4.1.28507.81.3.5 | ||||||||||||||||
notification · current Dew Point Difference limits exceeded | |||||||||||||||||
| !epc8031OVPEvt | 1.3.6.1.4.1.28507.81.3.6 | ||||||||||||||||
notification · current Event is triggered when the OVP status changes
| |||||||||||||||||
| !epc8031LineAmperageEvt | 1.3.6.1.4.1.28507.81.3.7 | ||||||||||||||||
notification · current Event is triggered when a measured current is crossing the entered limits | |||||||||||||||||
| !epc8031LineResidualCurrentEvt | 1.3.6.1.4.1.28507.81.3.8 | ||||||||||||||||
notification · current Event is triggered when a measured residual current Type A is crossing the entered limits | |||||||||||||||||
| !epc8031RCMBCurrentRMSEvt | 1.3.6.1.4.1.28507.81.3.18 | ||||||||||||||||
notification · current Event is triggered when a measured residual current Type B RMS is crossing the entered limits | |||||||||||||||||
| !epc8031RCMBCurrentDCEvt | 1.3.6.1.4.1.28507.81.3.19 | ||||||||||||||||
notification · current Event is triggered when a measured residual current Type B DC is crossing the entered limits | |||||||||||||||||
| !epc8031RCMBSigEvt | 1.3.6.1.4.1.28507.81.3.23 | ||||||||||||||||
notification · current Event is triggered when outputs of RCMB module changes | |||||||||||||||||
| !epc8031RCMBErrEvt | 1.3.6.1.4.1.28507.81.3.24 | ||||||||||||||||
notification · current Event is triggered when error state of RCMB module changes | |||||||||||||||||
| !epc8031ExtInputEvt | 1.3.6.1.4.1.28507.81.3.25 | ||||||||||||||||
notification · current Change of external sensor input. | |||||||||||||||||
| !epc8031LineVoltageEvt | 1.3.6.1.4.1.28507.81.3.26 | ||||||||||||||||
notification · current Event is triggered when a measured voltage is crossing the entered limits | |||||||||||||||||
| !epc8031LinePowerEvt | 1.3.6.1.4.1.28507.81.3.27 | ||||||||||||||||
notification · current Event is triggered when a measured power is crossing the entered limits | |||||||||||||||||
Traps / Notifications
- epc8031AirPressureEvtSen
1.3.6.1.4.1.28507.81.3.4 - epc8031DewPtDiffEvtSen
1.3.6.1.4.1.28507.81.3.5 - epc8031ExtInputEvt
1.3.6.1.4.1.28507.81.3.25 - epc8031HygroEvtSen
1.3.6.1.4.1.28507.81.3.3 - epc8031LineAmperageEvt
1.3.6.1.4.1.28507.81.3.7 - epc8031LinePowerEvt
1.3.6.1.4.1.28507.81.3.27 - epc8031LineResidualCurrentEvt
1.3.6.1.4.1.28507.81.3.8 - epc8031LineVoltageEvt
1.3.6.1.4.1.28507.81.3.26 - epc8031OVPEvt
1.3.6.1.4.1.28507.81.3.6 - epc8031RCMBCurrentDCEvt
1.3.6.1.4.1.28507.81.3.19 - epc8031RCMBCurrentRMSEvt
1.3.6.1.4.1.28507.81.3.18 - epc8031RCMBErrEvt
1.3.6.1.4.1.28507.81.3.24 - epc8031RCMBSigEvt
1.3.6.1.4.1.28507.81.3.23 - epc8031SwitchEvtPort
1.3.6.1.4.1.28507.81.3.1 - epc8031TempEvtSen
1.3.6.1.4.1.28507.81.3.2