GUDEADS-EPC8021-MIB
Gude Analog- und Digitalsysteme GmbHExpert Power Control 8021 MIB
snmptranslate -m GUDEADS-EPC8021-MIB -Tpsnmpwalk -v2c -c <community> -m GUDEADS-EPC8021-MIB <host> 1.3.6.1.4.1.28507Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Igudeads | 1.3.6.1.4.1.28507 | |||
identity Expert Power Control 8021 MIB | ||||
| NgadsEPC8021 | 1.3.6.1.4.1.28507.77 | |||
| Nepc8021Objects | 1.3.6.1.4.1.28507.77.1 | |||
| Nepc8021CommonConfig | 1.3.6.1.4.1.28507.77.1.1 | |||
| Nepc8021SNMPaccess | 1.3.6.1.4.1.28507.77.1.1.1 | |||
| Sepc8021TrapCtrl | 1.3.6.1.4.1.28507.77.1.1.1.1 | Integer32 (0..3) | RW | |
scalar · Integer32 (0..3) · read-write · current 0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3 | ||||
| Tepc8021TrapIPTable | 1.3.6.1.4.1.28507.77.1.1.1.2 | NA | ||
table · not-accessible · current list of all Trap receiver | ||||
| Repc8021TrapIPEntry | 1.3.6.1.4.1.28507.77.1.1.1.2.1 | NA | ||
row · not-accessible · current an entry containing management informations regarding the list of trap receivers
| ||||
| Cepc8021TrapIPIndex | 1.3.6.1.4.1.28507.77.1.1.1.2.1.1 | Integer32 (1..8) | RO | |
column · Integer32 (1..8) · read-only · current A unique value, greater than zero, for each receiver slot. | ||||
| Cepc8021TrapAddr | 1.3.6.1.4.1.28507.77.1.1.1.2.1.2 | OCTET STRING (SIZE (0..99)) | RW | |
column · OCTET STRING (SIZE (0..99)) · read-write · current DNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot. | ||||
| Nepc8021DeviceInfo | 1.3.6.1.4.1.28507.77.1.1.2 | |||
| Sepc8021ProdName | 1.3.6.1.4.1.28507.77.1.1.2.1 | OCTET STRING | RO | |
scalar · OCTET STRING · read-only · current The Product Name of the device. | ||||
| Sepc8021FWVersion | 1.3.6.1.4.1.28507.77.1.1.2.2 | OCTET STRING | RO | |
scalar · OCTET STRING · read-only · current Firmware Version of the device. | ||||
| Sepc8021HostName | 1.3.6.1.4.1.28507.77.1.1.2.3 | OCTET STRING | RO | |
scalar · OCTET STRING · read-only · current The configured Host Name. | ||||
| Sepc8021PhysAddress | 1.3.6.1.4.1.28507.77.1.1.2.4 | OCTET STRING | RO | |
scalar · OCTET STRING · read-only · current The MAC address of the device. | ||||
| Sepc8021SerialNumber | 1.3.6.1.4.1.28507.77.1.1.2.5 | Unsigned32 | RO | |
scalar · Unsigned32 · read-only · current The Serial Number of the device. Not available for all devices. Production start 2026. | ||||
| Nepc8021DeviceConfig | 1.3.6.1.4.1.28507.77.1.2 | |||
| Nepc8021IntActors | 1.3.6.1.4.1.28507.77.1.3 | |||
| Nepc8021relayports | 1.3.6.1.4.1.28507.77.1.3.1 | |||
| Sepc8021portNumber | 1.3.6.1.4.1.28507.77.1.3.1.1 | Integer32 (1..4) | RO | |
scalar · Integer32 (1..4) · read-only · current The number of Relay Ports | ||||
| Tepc8021portTable | 1.3.6.1.4.1.28507.77.1.3.1.2 | NA | ||
table · not-accessible · current list of all EPC Relay Ports | ||||
| Repc8021portEntry | 1.3.6.1.4.1.28507.77.1.3.1.2.1 | NA | ||
row · not-accessible · current An entry containing management information applicable to a particular relay port.
| ||||
| Cepc8021PortIndex | 1.3.6.1.4.1.28507.77.1.3.1.2.1.1 | Integer32 (1..4) | RO | |
column · Integer32 (1..4) · read-only · current A unique value, greater than zero, for each Relay Port. | ||||
| Cepc8021PortName | 1.3.6.1.4.1.28507.77.1.3.1.2.1.2 | OCTET STRING (SIZE (0..15)) | RW | |
column · OCTET STRING (SIZE (0..15)) · read-write · current A textual string containing name of a Relay Port. | ||||
| Cepc8021PortState | 1.3.6.1.4.1.28507.77.1.3.1.2.1.3 | INTEGER | RW | |
column · INTEGER · read-write · current current state of a Relay Port
| ||||
| Cepc8021PortSwitchCount | 1.3.6.1.4.1.28507.77.1.3.1.2.1.4 | Integer32 | RO | |
column · Integer32 · read-only · current The total number of switch actions ocurred on a Relay Port. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here. | ||||
| Cepc8021PortStartupMode | 1.3.6.1.4.1.28507.77.1.3.1.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current set Mode of startup sequence (off, on , remember last state)
| ||||
| Cepc8021PortStartupDelay | 1.3.6.1.4.1.28507.77.1.3.1.2.1.6 | Integer32 | RW | |
column · Integer32 · read-write · current Delay in sec for startup action
| ||||
| Cepc8021PortRepowerTime | 1.3.6.1.4.1.28507.77.1.3.1.2.1.7 | Integer32 (0..65535) | RW | |
column · Integer32 (0..65535) · read-write · current Delay in sec for repower port after switching off
| ||||
| Cepc8021PortResetDuration | 1.3.6.1.4.1.28507.77.1.3.1.2.1.8 | Integer32 (0..65535) | RW | |
column · Integer32 (0..65535) · read-write · current Delay in sec for turning Port on again after Reset action
| ||||
| Sepc8021Buzzer | 1.3.6.1.4.1.28507.77.1.3.10 | Integer32 (0..1) | RW | |
scalar · Integer32 (0..1) · read-write · current turn Buzzer on and off
| ||||
| Nepc8021ExtActors | 1.3.6.1.4.1.28507.77.1.4 | |||
| Nepc8021IntSensors | 1.3.6.1.4.1.28507.77.1.5 | |||
| Nepc8021PowerChan | 1.3.6.1.4.1.28507.77.1.5.1 | |||
| Sepc8021ActivePowerChan | 1.3.6.1.4.1.28507.77.1.5.1.1 | Unsigned32 (1) | RO | |
scalar · Unsigned32 (1) · read-only · current Number of suppported Power Channels. | ||||
| Tepc8021PowerTable | 1.3.6.1.4.1.28507.77.1.5.1.2 | NA | ||
table · not-accessible · current All available Channel Interfaces. | ||||
| Repc8021PowerEntry | 1.3.6.1.4.1.28507.77.1.5.1.2.1 | NA | ||
row · not-accessible · current An entry containing management information applicable to a particular Power Channel.
| ||||
| Cepc8021PowerIndex | 1.3.6.1.4.1.28507.77.1.5.1.2.1.1 | Integer32 (1) | RO | |
column · Integer32 (1) · read-only · current Index of Power Channel entries | ||||
| Cepc8021ChanStatus | 1.3.6.1.4.1.28507.77.1.5.1.2.1.2 | Integer32 (0..1) | RO | |
column · Integer32 (0..1) · read-only · current 0 = data not active, 1 = data valid | ||||
| Cepc8021AbsEnergyActive | 1.3.6.1.4.1.28507.77.1.5.1.2.1.3 | Gauge32 | RO | |
column · Gauge32 · read-only · current Absolute Active Energy counter.
| ||||
| Cepc8021PowerActive | 1.3.6.1.4.1.28507.77.1.5.1.2.1.4 | Integer32 | RO | |
column · Integer32 · read-only · current Active Power
| ||||
| Cepc8021Current | 1.3.6.1.4.1.28507.77.1.5.1.2.1.5 | Gauge32 | RO | |
column · Gauge32 · read-only · current Actual Curent on Power Channel.
| ||||
| Cepc8021Voltage | 1.3.6.1.4.1.28507.77.1.5.1.2.1.6 | Gauge32 | RO | |
column · Gauge32 · read-only · current Actual Voltage on Power Channel
| ||||
| Cepc8021Frequency | 1.3.6.1.4.1.28507.77.1.5.1.2.1.7 | Gauge32 | RO | |
column · Gauge32 · read-only · current Frequency of Power Channel
| ||||
| Cepc8021PowerFactor | 1.3.6.1.4.1.28507.77.1.5.1.2.1.8 | Integer32 | RO | |
column · Integer32 · read-only · current Power Factor of Channel between -1.0 and 1.00
| ||||
| Cepc8021Pangle | 1.3.6.1.4.1.28507.77.1.5.1.2.1.9 | Integer32 | RO | |
column · Integer32 · read-only · current Phase Angle between Voltage and L Line Current between -180.0 and 180.0
| ||||
| Cepc8021PowerApparent | 1.3.6.1.4.1.28507.77.1.5.1.2.1.10 | Integer32 | RO | |
column · Integer32 · read-only · current L Line Mean Apparent Power
| ||||
| Cepc8021PowerReactive | 1.3.6.1.4.1.28507.77.1.5.1.2.1.11 | Integer32 | RO | |
column · Integer32 · read-only · current L Line Mean Reactive Power
| ||||
| Cepc8021AbsEnergyReactive | 1.3.6.1.4.1.28507.77.1.5.1.2.1.12 | Gauge32 | RO | |
column · Gauge32 · read-only · current Absolute Reactive Energy counter.
| ||||
| Cepc8021AbsEnergyActiveResettable | 1.3.6.1.4.1.28507.77.1.5.1.2.1.13 | Gauge32 | RW | |
column · Gauge32 · read-write · current Resettable Absolute Active Energy counter. Writing '0' resets all resettable counter.
| ||||
| Cepc8021AbsEnergyReactiveResettable | 1.3.6.1.4.1.28507.77.1.5.1.2.1.14 | Gauge32 | RO | |
column · Gauge32 · read-only · current Resettable Absolute Reactive Energy counter.
| ||||
| Cepc8021ResetTime | 1.3.6.1.4.1.28507.77.1.5.1.2.1.15 | Gauge32 | RO | |
column · Gauge32 · read-only · current Time in seconds since last Energy Counter reset.
| ||||
| Cepc8021ForwEnergyActive | 1.3.6.1.4.1.28507.77.1.5.1.2.1.16 | Gauge32 | RO | |
column · Gauge32 · read-only · current Forward Active Energy counter.
| ||||
| Cepc8021ForwEnergyReactive | 1.3.6.1.4.1.28507.77.1.5.1.2.1.17 | Gauge32 | RO | |
column · Gauge32 · read-only · current Forward Reactive Energy counter.
| ||||
| Cepc8021ForwEnergyActiveResettable | 1.3.6.1.4.1.28507.77.1.5.1.2.1.18 | Gauge32 | RO | |
column · Gauge32 · read-only · current Resettable Forward Active Energy counter.
| ||||
| Cepc8021ForwEnergyReactiveResettable | 1.3.6.1.4.1.28507.77.1.5.1.2.1.19 | Gauge32 | RO | |
column · Gauge32 · read-only · current Resettable Forward Reactive Energy counter.
| ||||
| Cepc8021RevEnergyActive | 1.3.6.1.4.1.28507.77.1.5.1.2.1.20 | Gauge32 | RO | |
column · Gauge32 · read-only · current Reverse Active Energy counter.
| ||||
| Cepc8021RevEnergyReactive | 1.3.6.1.4.1.28507.77.1.5.1.2.1.21 | Gauge32 | RO | |
column · Gauge32 · read-only · current Reverse Reactive Energy counter.
| ||||
| Cepc8021RevEnergyActiveResettable | 1.3.6.1.4.1.28507.77.1.5.1.2.1.22 | Gauge32 | RO | |
column · Gauge32 · read-only · current Resettable Reverse Active Energy counter.
| ||||
| Cepc8021RevEnergyReactiveResettable | 1.3.6.1.4.1.28507.77.1.5.1.2.1.23 | Gauge32 | RO | |
column · Gauge32 · read-only · current Resettable Reverse Reactive Energy counter.
| ||||
| Cepc8021ResidualCurrent | 1.3.6.1.4.1.28507.77.1.5.1.2.1.24 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Actual Residual Current on Power Channel. According Type A IEC 60755. Only visible on models that support this feature.
| ||||
| Cepc8021LineSensorName | 1.3.6.1.4.1.28507.77.1.5.1.2.1.100 | OCTET STRING (SIZE (0..32)) | RW | |
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of a Line Sensor | ||||
| Tepc8021OVPTable | 1.3.6.1.4.1.28507.77.1.5.2 | NA | ||
table · not-accessible · current Overvoltage Protection Table This table may not be present on devices without OVP feature | ||||
| Repc8021OVPEntry | 1.3.6.1.4.1.28507.77.1.5.2.1 | NA | ||
row · not-accessible · current
| ||||
| Cepc8021OVPIndex | 1.3.6.1.4.1.28507.77.1.5.2.1.1 | Integer32 (1) | RO | |
| Cepc8021OVPStatus | 1.3.6.1.4.1.28507.77.1.5.2.1.2 | INTEGER | RO | |
column · INTEGER · read-only · current shows the status of the built-in Overvoltage Protection
| ||||
| Nepc8021CPUSensors | 1.3.6.1.4.1.28507.77.1.5.14 | |||
| Sepc8021CPUSensorVsystem | 1.3.6.1.4.1.28507.77.1.5.14.1 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current System Voltage on CPU Board
| ||||
| Sepc8021CPUSensorVaux | 1.3.6.1.4.1.28507.77.1.5.14.2 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current Auxiliary Voltage on CPU Board
| ||||
| Sepc8021CPUSensorVmain | 1.3.6.1.4.1.28507.77.1.5.14.3 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current Main Voltage on CPU Board
| ||||
| Sepc8021CPUSensorTcpu | 1.3.6.1.4.1.28507.77.1.5.14.4 | Integer32 | RO | |
scalar · Integer32 · read-only · current Temperature on CPU Board | ||||
| Nepc8021NTPClient | 1.3.6.1.4.1.28507.77.1.5.15 | |||
| Sepc8021NTPTimeValid | 1.3.6.1.4.1.28507.77.1.5.15.1 | INTEGER | RO | |
scalar · INTEGER · read-only · current Show if valid Time is received
| ||||
| Sepc8021NTPUnixTime | 1.3.6.1.4.1.28507.77.1.5.15.2 | Unsigned32 | RO | |
scalar · Unsigned32 · read-only · current show received NTP time as unixtime (secs since 1 January 1970)
| ||||
| Sepc8021NTPLastValidTimestamp | 1.3.6.1.4.1.28507.77.1.5.15.3 | Unsigned32 | RO | |
scalar · Unsigned32 · read-only · current show seconds since last valid NTP timestamp received
| ||||
| Tepc8021RCMBInfoTable | 1.3.6.1.4.1.28507.77.1.5.16 | NA | ||
table · not-accessible · current RCMB Module Information Only visible on models that support this feature. | ||||
| Repc8021RCMBInfoEntry | 1.3.6.1.4.1.28507.77.1.5.16.1 | NA | ||
row · not-accessible · current
| ||||
| Cepc8021RCMBInfoIndex | 1.3.6.1.4.1.28507.77.1.5.16.1.1 | Integer32 (1) | RO | |
column · Integer32 (1) · read-only · current Index of RCMB Info entries | ||||
| Cepc8021RCMBCurrentRMS | 1.3.6.1.4.1.28507.77.1.5.16.1.2 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Actual Residual Current RMS on Power Channel. According Type B IEC 60755. Only visible on models that support this feature.
| ||||
| Cepc8021RCMBCurrentDC | 1.3.6.1.4.1.28507.77.1.5.16.1.3 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Actual Residual Current DC on Power Channel. According Type B IEC 60755. Only visible on models that support this feature.
| ||||
| Cepc8021RCMBOutputRMS | 1.3.6.1.4.1.28507.77.1.5.16.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current shows the output S1 of the RCMB module
| ||||
| Cepc8021RCMBOutputDC | 1.3.6.1.4.1.28507.77.1.5.16.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current shows the output S2 of the RCMB module
| ||||
| Cepc8021RCMBModuleStatus | 1.3.6.1.4.1.28507.77.1.5.16.1.6 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current RCMB Module Status Word | ||||
| Nepc8021ExtSensors | 1.3.6.1.4.1.28507.77.1.6 | |||
| Tepc8021SensorTable | 1.3.6.1.4.1.28507.77.1.6.1 | NA | ||
| Repc8021SensorEntry | 1.3.6.1.4.1.28507.77.1.6.1.1 | NA | ||
row · not-accessible · current
| ||||
| Cepc8021SensorIndex | 1.3.6.1.4.1.28507.77.1.6.1.1.1 | Integer32 (1..2) | RO | |
| Cepc8021TempSensor | 1.3.6.1.4.1.28507.77.1.6.1.1.2 | Integer32 | RO | |
column · Integer32 · read-only · current actual temperature | ||||
| Cepc8021HygroSensor | 1.3.6.1.4.1.28507.77.1.6.1.1.3 | Integer32 | RO | |
column · Integer32 · read-only · current actual humidity
| ||||
| Cepc8021AirPressure | 1.3.6.1.4.1.28507.77.1.6.1.1.5 | Integer32 | RO | |
column · Integer32 · read-only · current actual air pressure | ||||
| Cepc8021DewPoint | 1.3.6.1.4.1.28507.77.1.6.1.1.6 | Integer32 | RO | |
column · Integer32 · read-only · current dew point for actual temperature and humidity | ||||
| Cepc8021DewPointDiff | 1.3.6.1.4.1.28507.77.1.6.1.1.7 | Integer32 | RO | |
column · Integer32 · read-only · current difference between dew point and actual temperature (Temp - DewPoint) | ||||
| Cepc8021ExtSensorName | 1.3.6.1.4.1.28507.77.1.6.1.1.32 | OCTET STRING (SIZE (0..32)) | RW | |
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of a external Sensor | ||||
| Nepc8021ExtInputs | 1.3.6.1.4.1.28507.77.1.6.2 | |||
| Sepc8021ExtActiveInputs | 1.3.6.1.4.1.28507.77.1.6.2.1 | Unsigned32 | RO | |
scalar · Unsigned32 · read-only · current Number of suppported Input Channels. | ||||
| Tepc8021ExtInputTable | 1.3.6.1.4.1.28507.77.1.6.2.2 | NA | ||
| Repc8021ExtInputEntry | 1.3.6.1.4.1.28507.77.1.6.2.2.1 | NA | ||
row · not-accessible · current
| ||||
| Cepc8021ExtInputIndex | 1.3.6.1.4.1.28507.77.1.6.2.2.1.1 | Unsigned32 | RO | |
| Cepc8021ExtInput | 1.3.6.1.4.1.28507.77.1.6.2.2.1.2 | INTEGER | RO | |
column · INTEGER · read-only · current Input state of device
| ||||
| Cepc8021ExtInputToggleCount | 1.3.6.1.4.1.28507.77.1.6.2.2.1.3 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Number of times the Input has changed its state. | ||||
| Cepc8021ExtInputName | 1.3.6.1.4.1.28507.77.1.6.2.2.1.32 | OCTET STRING (SIZE (0..32)) | RW | |
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of the Input | ||||
| Cepc8021ExtInputPortNum | 1.3.6.1.4.1.28507.77.1.6.2.2.1.33 | Integer32 | RO | |
column · Integer32 · read-only · current Number of external Sensor Port when value greater zero, else device built-in Input. | ||||
| Cepc8021ExtInputBlockIndex | 1.3.6.1.4.1.28507.77.1.6.2.2.1.34 | Integer32 | RO | |
column · Integer32 · read-only · current Either index of device built-in Input, or index of Input in external sensor. | ||||
| Nepc8021Conf | 1.3.6.1.4.1.28507.77.2 | |||
| Nepc8021Groups | 1.3.6.1.4.1.28507.77.2.1 | |||
| Gepc8021BasicGroup | 1.3.6.1.4.1.28507.77.2.1.1 | |||
group · current Basic objects.
| ||||
| Gepc8021NotificationGroup | 1.3.6.1.4.1.28507.77.2.1.2 | |||
group · current
| ||||
| Nepc8021Compls | 1.3.6.1.4.1.28507.77.2.2 | |||
| Nevents | 1.3.6.1.4.1.28507.77.3 | |||
| !epc8021SwitchEvtPort | 1.3.6.1.4.1.28507.77.3.1 | |||
notification · current Event is triggered when a port is switched | ||||
| !epc8021TempEvtSen | 1.3.6.1.4.1.28507.77.3.2 | |||
| !epc8021HygroEvtSen | 1.3.6.1.4.1.28507.77.3.3 | |||
| !epc8021AirPressureEvtSen | 1.3.6.1.4.1.28507.77.3.4 | |||
| !epc8021DewPtDiffEvtSen | 1.3.6.1.4.1.28507.77.3.5 | |||
notification · current Dew Point Difference limits exceeded | ||||
| !epc8021OVPEvt | 1.3.6.1.4.1.28507.77.3.6 | |||
notification · current Event is triggered when the OVP status changes
| ||||
| !epc8021LineAmperageEvt | 1.3.6.1.4.1.28507.77.3.7 | |||
notification · current Event is triggered when a measured current is crossing the entered limits | ||||
| !epc8021LineResidualCurrentEvt | 1.3.6.1.4.1.28507.77.3.8 | |||
notification · current Event is triggered when a measured residual current Type A is crossing the entered limits | ||||
| !epc8021RCMBCurrentRMSEvt | 1.3.6.1.4.1.28507.77.3.18 | |||
notification · current Event is triggered when a measured residual current Type B RMS is crossing the entered limits | ||||
| !epc8021RCMBCurrentDCEvt | 1.3.6.1.4.1.28507.77.3.19 | |||
notification · current Event is triggered when a measured residual current Type B DC is crossing the entered limits | ||||
| !epc8021RCMBSigEvt | 1.3.6.1.4.1.28507.77.3.23 | |||
notification · current Event is triggered when outputs of RCMB module changes | ||||
| !epc8021RCMBErrEvt | 1.3.6.1.4.1.28507.77.3.24 | |||
notification · current Event is triggered when error state of RCMB module changes | ||||
| !epc8021ExtInputEvt | 1.3.6.1.4.1.28507.77.3.25 | |||
notification · current Change of external sensor input. | ||||
| !epc8021LineVoltageEvt | 1.3.6.1.4.1.28507.77.3.26 | |||
notification · current Event is triggered when a measured voltage is crossing the entered limits | ||||
| !epc8021LinePowerEvt | 1.3.6.1.4.1.28507.77.3.27 | |||
notification · current Event is triggered when a measured power is crossing the entered limits | ||||
Traps / Notifications
- epc8021AirPressureEvtSen
1.3.6.1.4.1.28507.77.3.4 - epc8021DewPtDiffEvtSen
1.3.6.1.4.1.28507.77.3.5 - epc8021ExtInputEvt
1.3.6.1.4.1.28507.77.3.25 - epc8021HygroEvtSen
1.3.6.1.4.1.28507.77.3.3 - epc8021LineAmperageEvt
1.3.6.1.4.1.28507.77.3.7 - epc8021LinePowerEvt
1.3.6.1.4.1.28507.77.3.27 - epc8021LineResidualCurrentEvt
1.3.6.1.4.1.28507.77.3.8 - epc8021LineVoltageEvt
1.3.6.1.4.1.28507.77.3.26 - epc8021OVPEvt
1.3.6.1.4.1.28507.77.3.6 - epc8021RCMBCurrentDCEvt
1.3.6.1.4.1.28507.77.3.19 - epc8021RCMBCurrentRMSEvt
1.3.6.1.4.1.28507.77.3.18 - epc8021RCMBErrEvt
1.3.6.1.4.1.28507.77.3.24 - epc8021RCMBSigEvt
1.3.6.1.4.1.28507.77.3.23 - epc8021SwitchEvtPort
1.3.6.1.4.1.28507.77.3.1 - epc8021TempEvtSen
1.3.6.1.4.1.28507.77.3.2